1 home inspection report Home. Safe. Home. Each office is independently owned and operated The HomeTeam Inspection Service, Inc. All rights reserved.

2 What is a home inspection? The purpose of a home inspection is to visually examine the readily accessible systems and components of the home. The inspectors are not required to move personal property, materials or any other objects that may impede access or limit visibility. Items that are unsafe or not functioning, in the opinion of the inspector, will be described in accordance with the standards of practice by which inspectors abide. What does this report mean to you? This inspection report is not intended as a guarantee, warranty or an insurance policy. Because your home is one of the largest investments you will ever make, use the information provided in this report and discuss the findings with your real estate agent and family to understand the current condition of the home. Our inspections exceed the highest industry standards. FAST Because we use a team of inspectors, each an expert in his or her field, our inspections are performed with greater efficiency and more expertise and therefore exceed the highest industry standards. We are pleased to provide this detailed report as a service to you, our client. TRUSTED We believe in your dream of home ownership. We want to help you get into your dream home. Therefore, we take great pride in assisting you with this decision making process. This is certainly a major achievement in your life. We are happy to be part of this important occasion and we appreciate the opportunity to help you realize your dream. We exceed your expectations. Buying your new home is a major decision. Much hinges on the current condition of the home you have chosen. That is why we have developed the HomeTeam Inspection Report. Backed by HomeTeam s experience with hundreds of thousands of home inspections over the years, the report in your hand has been uniquely designed to meet and exceed the expectations of today s homebuyers. We are proud to deliver this high-quality document for your peace of mind. If you have any questions while reviewing this report, please contact us immediately. Thank you for allowing us the opportunity to serve you. ACCURATE

3 GENERAL DESCRIPTION Throughout this report, the terms "right" and "left" are used to describe the home as viewed from the street. A system or component has a major visual defect if it is either unsafe or not functioning and cannot be replaced or rendered safe or functional for less than $1,000. When major visual defects are observed or minor repairs need to be made, we recommend you consult a qualified licensed professional. Cost estimates are advised prior to closing. All contractors should work for you, as their evaluation/observation may make you aware of findings not listed in our report. This report is not a technically exhaustive inspection. We can help arrange for additional specialist inspections, (for a fee) should you the client request one. The HomeTeam inspects for evidence of structural failure and safety concerns only. We can give an excellent overview of the property but may not find every defect, whether visible or not. We will not eliminate risk. We can not predict the future or inspect items we can not see. Moving furniture, any dismantling (other than the service panel cover should it be accessible) or lighting gas pilots is not within the scope of the inspection. The cosmetic condition of the paint, wall covering, carpeting, window coverings, etc., may not be addressed. All conditions are reported, as they existed at the time of the inspection. Clients are urged to perform a full walk-through before closing. Checking areas not visible at the time of the inspection due to area rugs, furnishings, or other lack of access is strongly recommended. Also operating appliances, plumbing, etc. are recommended. If items are deemed inaccessible, not tested, not visible or snow covered we can return, for a fee, or you should contact a licensed contractor to inspect these areas or items once they are made accessible, visible or uncovered. These areas should be evaluated prior to closing. Return visits start as low as $ Routine maintenance and safety items are not within the scope of this inspection unless they otherwise constitute major, visually observable defects. Although some maintenance and/or safety items may be disclosed, this report does not include all maintenance or safety items, and should not be relied upon for such items. The approximate temperature at the time of the inspection was degrees Fahrenheit, and the weather was cloudy. The utilities were on at the time of the inspection. The buyer was present at the time of the inspection. The inspected property consisted of a two-story walkout wood-framed structure with brick and composite board siding that was occupied at the time of the inspection. There were no major visual defects on the visual portions of the siding, flashing, soffit, fascia or eaves. Some thin cracking of building materials is common and ordinarily considered a part of routine maintenance. Paint was needed on several areas of the wood trim and the front wood shake siding. Page 2 of 14

4 The home was situated on a level to sloped lot. The general grade around the home appeared to be adequate to direct rainwater away from the foundation. The grade around the home, when possible should slope away from the foundation, at about one inch per foot for about three to five feet from the foundation. The age of the home, as reported by the buyer, was said to be 18 years old. There was a brick walkway leading to a brick/concrete cap porch in the front of the home. There were no major visual defects observed in the walkway or the porch. As a safety precaution, porches and stairs should have guard rails. Surfaces that pitch towards the home increase the probability of water infiltration. When any cracks in the driveway or walkway measuring up to a 1/4 inch, are found, cosmetic repair is advised. Any large cracks or differential separation (lifting), on the property could be a hazard for which the property owner may be responsible. Large cracks should be repaired. FOUNDATION The foundation was constructed of poured concrete. A single inspection cannot determine whether movement of a foundation has ceased. Any cracks should be monitored regularly. There were no major visual defects observed on the visible portions of the foundation. FLOOR STRUCTURE The visible floor structure consisted of a plywood sub floor, supported by two-inch by ten -inch wood joists spaced sixteen inches on center. A eight-inch steel flange center beam and three-inch steel posts or piers were present for load bearing support. There were no major visual defects observed in the visible floor structure. There was limited visibility of the floor structure do to the ceiling tile ceiling. ROOF STRUCTURE The roof was a gable and valley design covered with asphalt/fiberglass shingles. Observation of the roof surfaces, flashing, and penetrations was performed at ground level only. The age of the roof covering, as reported by the buyer, was approximately 18 years. There appeared to be one layer of shingles on the roof at the time of the inspection. There was light curling and light surface wear observed on the roof shingles at the time of the inspection. These conditions indicate the roof shingles were nearing the end of their useful life. There were no major visual defects detected on the exterior of the roof. This visual roof inspection is not intended as a warranty or an estimate on the remaining life of the roof. Any roof metal, especially the flashing and valleys, must be kept well painted with a paint specially formulated for the use. It is possible leaks may develop in the future. The shingles are nearing the end of their useful life-budget for new shingles. Page 3 of 14

5 There was rot to the wood sheathing on the left side of the roof, between the chimney and the garage. Consult contractor for cost estimates and repairs prior to closing. There was one chimney. Observation of the chimney exterior was made from the the roof. There were no major visual defects observed on the exterior. Chimneys and B vents are a common source of water infiltration, both at the roof and in the dwelling. We suggest you check these areas regularly and maintain as needed. A rain cap can reduce the chances of water infiltration at the chimney. The roof drainage system consisted of aluminum gutters and downspouts, which appeared to be functional at the time of the inspection. Gutters and downspouts should receive routine maintenance to prevent premature failure. There were no major visual defects observed on the visible portions of the gutters or downspouts. All downspouts should terminate away from the building foundation area, by use of splash blocks or underground drainage pipe. There was a concrete driveway on the left side of the home, which led to the attached garage. There were no major visual defects observed in the driveway. Cracks and settlement were noted in the driveway. Corrections are recommend to prevent further deterioration and tripping could be an issue for which the home owner is responsible. Page 4 of 14

6 There was settlement where the driveway and garage floor meet, this is a trip hazard. GARAGE The attached garage was designed for two cars with access provided by one overhead-style door. The Vemco brand electric garage door opener was tested and found to be functional. There was an automatic safety reverse present on the overhead door. The automatic safety reverse on the garage door was tested and found to be functional. The concrete garage floor was in good condition. There were no major visual defects observed in the garage or the door mechanisms. The separation walls, ceilings and doors between the dwelling unit and the attached garage were in satisfactory condition. We suggest you keep attic hatches closed, repair any holes or damage that exist or occur and not create openings between the home and garage. This is to help keep the migration of smoke or fire from entering the house in the event of a fire in the garage. Page 5 of 14

7 FIRST LIVING LEVEL The first level consisted of Kitchen, dining room, living room, den, half bath, laundry room and family room. There were no major visual defects observed on the first level. Ventilation for the bathroom(s) was provided by a fan that was functional at the time of the inspection. The HomeTeam inspects for evidence of structural failure and safety concerns only. The cosmetic condition of the paint, wall covering, carpeting, window coverings, etc., are not addressed. Because leaks can occur at any time, plumbing should be checked regularly. We advise that all floors, tile edges and tub/shower walls be caulked and sealed to prevent moisture penetration. All missing/damaged grouting and caulk should be replaced at once. The visible portions of the dryer vent were inspected and were functional at the time of the inspection. The venting was adequate to vent the dryer to the exterior of the home. We suggest using rigid, smooth metal exhaust pipe for dryer exhaust as flexible pipe has been indicated in house fires. Flexible dryer vent hose was being used. DECK There was a wood deck located in the back of the home. There did not appear to be significant deterioration of the wood. A wood deck should be cleaned and sealed regularly to prevent deterioration. There were no major visual defects observed on the visible portions of the deck or support structure. As a safety precaution, above ground decks and stairs should have guard rails and hand rails that are properly spaced and secure. There were a few loose rails that need to be secured. Page 6 of 14

8 There were several nails sticking up from the deck boards, repairs are recommended. The visible portions of the cabinets and counter tops were in good condition. Appliance inspection is beyond the scope of the inspection but, as a courtesy to our clients, we perform a visual check of built-in appliances. The appliances are old. The appliances were turned on to check operational function only. No warranty, express or implied, is given for the continued operational integrity of the appliances or their components. The kitchen contained the following appliances: The microwave oven was inspected and did appear to be functional. The accuracy of the clocks, timers and settings are not within the scope of this inspection. The visible portions of the venting system was inspected and did appear to be functional at the time of the inspection. The exhaust capacity is not within the scope of this inspection. Cleaning the fan and filter may increase the exhaust capability. The disposal was inspected and did appear to be functional. The efficiency rating is not within the scope of the inspection. The dishwasher was observed through a complete cycle and did appear to be functional when set on the "wash" and "drain" cycle. The refrigerator was inspected and did appear to be functional. The temperature setting and icemaker, if present, are not within the scope of the inspection. The electric built-in oven and counter top range was inspected and did appear to be functional. The accuracy of the clock, timers and settings on ovens are not within the scope of this inspection. Page 7 of 14

9 The interior wall and ceiling surfaces were finished with drywall. Possible problem areas may not be identified if the interior wall and ceiling surfaces have been recently painted. There were no major visual defects observed in the interior walls or ceilings. Stain on the master bedroom ceiling, this area appeared to be dry at the time. Consult the seller about any prior issues. Further evaluation may be needed. WINDOWS, DOORS, WALLS AND CEILINGS A representative number of accessible windows and doors were operated and found to be functional. The primary windows were constructed of wood and vinyl, double hung style with insulated glass. All exterior doors were operated and found to be functional. The exterior door locks should be changed or re keyed upon occupancy. All dead bolt locks should be thumb latch type and not keyed on the inside of the home as injury could occur during a fire. Possible problem areas may not be identified if the windows or doors have been recently painted. The windows in the dining room and family room have a detached or broken tension spring, bar, or cable that should be repaired or replaced. The tension spring, bar, or, cable is a safety device that holds the window in the open position. Two of the family room windows do not open. Page 8 of 14

10 FIREPLACE There was one fireplace in the home. The visual condition at the time of the inspection is indicated as follows. A gas-log fireplace was located in the family room. The damper did appear to be functional. There was no visual evidence of creosote buildup in the firebox and/or chimney. There were no cracks observed in the firebox or visible portions of the chimney. There is a strong gas odor at the gas logs. For safety reasons, a fireplace, "B" vent and the chimney or pipe to which it is vented should be cleaned and re-inspected before using, as there may be hidden defects, not fully visible at the time of the inspection. The fireplace, vent pipe and chimney if any were not tested for operation or function. Annual maintenance is recommended. When a fireplace has been altered from its original state such as adding gas logs to a natural fireplace then drafting could become an issue. Further testing and evaluation would need to be done. ATTIC STRUCTURE The attic was accessed through an opening in the bedroom closet. The attic above the living space was insulated with loose-fill and batted fiberglass insulation, approximately 8-inches in depth. Ventilation throughout the attic was provided by soffit and ridge vents. The roof structure consisted of two-inch by four-inch wood trusses spaced 24 inches on center and strand board sheathing. Because of the configuration of the trusses, which limited access, it was not possible to inspect all areas of the attic. There was no moisture visible in the attic space. There were no major visual defects observed in the attic or roof structure. The absence of visible indications of moisture is not necessarily conclusive evidence that the roof is free from leaks. The only way to be sure a roof does not leak is to inspect the underside of the roof during a heavy rain. Things were being stored in the attic. SECOND LIVING LEVEL The second level of the home consisted of master bedroom, master bath, three bedrooms and full bath. There were no major visual defects observed on the second level. Page 9 of 14

11 SMOKE ALARMS There were smoke alarms found in the house. For safety reasons, the smoke alarms should be tested upon occupancy. The batteries (if any) should be replaced with new ones when you move into the house, and tested on a monthly basis thereafter. We suggest you maintain smoke detectors on each level, inside each sleeping area and at each end of the home. We also recommend fire extinguishers and carbon monoxide detectors. ELECTRIC SERVICE The underground electric service wire entered the home on the exterior wall. The electric meter was located on the right exterior wall. The service wire entered a Challenger service panel, located on the basement wall with a 150 -amps and 120/240 volt rated capacity. The branch circuits within the panel were copper and aluminum in the 240 volt circuits. These branch circuits and the circuit breaker to which they were attached appeared to be appropriately matched. The visible house wiring consisted primarily of the romex type and appeared to be in good condition. Extension cords should not be used for any purpose other than as a temporary power source. Permanent approved wiring is advised in place of extension cords to any permanently installed electrical component. A representative number of installed lighting fixtures, switches, and receptacles located throughout the home were inspected and were found to be functional. The grounding and polarity of receptacles within six feet of plumbing fixtures, and those attached to ground fault circuit interrupters (GFCI), if present, were also tested. All GFCI receptacles and GFCI circuit breakers should be tested monthly. There were GFCI protected circuits located on the exterior, kitchen, bathroom and garage. The present and tested GFCI's were functional. Alarms, electronic keypads, remote control devices, landscape lighting, telephone and television, and all electric company equipment were beyond the scope of this inspection. The electrical service appeared to be adequate. There were no major visual defects observed in the electrical system. PLUMBING The visible water supply lines throughout the home were copper pipe. The water was supplied by a public water supply. The visible waste lines consisted of PVC pipe. The home was connected to a public sewer system. Water flow throughout the home was average. The functional drainage of the drain waste lines were adequate at the time of the inspection. There were no major visual defects observed in the visible portions of the plumbing system. There were hose faucet(s) on the exterior of the home. Gas lines need to be capped after a shut off valve or injury could occur. Page 10 of 14

12 All plumbing fixtures not permanently attached to a household appliance were operated and inspected for visible leaks. Once you move in we suggest installing an anti-siphon device on the utility tub faucet and all spigots, to reduce the chances of dirty water back flow into the drinking water. This is an inexpensive upgrade. All water closet flush valves were functional unless otherwise noted. We can not observe plumbing that is concealed and suggest you obtain the maintenance history of the homes plumbing. Prior to closing you can always have a plumbing contractor; with the proper equipment evaluate the lines to determine their condition. The water meter was located in the basement. The main water shutoff valve for the home was located at the meter. The gas meter was located on the right exterior wall. Although no actual testing was performed to detect the presence of gas fumes, there was no noticeable odor of gas detected at the time of the inspection. There was a 50- gallon capacity, natural gas water heater located in the basement. The water heater was manufactured by Bradford White. Information on the water heater indicated that it was manufactured about 5 to 6 years ago. The average life of a water heater is 15 years. The water heater was functional. There was an adequate venting system from the water heater to the exterior of the house. A temperature and pressure relief valve (T & P) was present. Because of the lime build-up typical of T & P valves, we do not test them. An overflow tube was present. It did terminate close to the floor. An overflow tube should terminate 4 to 6 inches from the floor. Your safety depends on the presence of a T & P valve and an overflow leg terminating close to the floor. BASEMENT: (LOWER LEVEL) The full basement was finished, and contained the following mechanical systems: furnace, water heater and sump pump. The basement appeared to be dry at the time of the inspection. Because the basement is below grade, there exists a vulnerability to moisture penetration after heavy rains. The basement has floor drainage. Water in the floor drain trap should be replenished periodically to eliminate the possibility of sewer gas venting into the basement. There were no major visual defects observed in the basement. The stairway (s) in the home was inspected and there were no major visual defects or visual safety concerns observed with the steps, stairways or handrails. Although some cracks were noted, the poured concrete basement floor appeared to be in satisfactory condition. There was a sump pump located in the basement. The sump pump functional. Page 11 of 14

13 HVAC INSPECTION REPORT The heating, ventilating and air conditioning system if any were inspected by the HomeTeam. Annual maintenance of the heating and cooling equipment is essential for safe and efficient performance, which will maximize the system's useful life. Periodic preventive maintenance is recommended to keep all units in good working condition. The home was heated by Payne natural gas forced air furnace,model Number PG9YAB060100AAAA,Serial Number 2210A60414,which appears to be approximately 3 years old. The unit was located in the basement of the home. It has an approximate net heating capacity of 100,000 BTUH. The flue, vents and automatic safety controls for the heating unit did appear to be functional. The heating system was found to be functional. The average life of most gas furnaces is Budget for a furnace when nearing or above this age. Without removing the burners to gain complete access, and with the limited viewing area of the heat exchanger, a thorough inspection is not possible. The electric outdoor air conditioner condensing unit was Payne, Model Number PA13NA048C and Serial Number 1510X6684. The unit is located on the right side of the home. This unit is approximately 3 year old. The cooling system was found to be functional. The average life of most Air Conditioners is years. Budget for an air conditioner when nearing or above this age. Periodic preventive maintenance is recommended to keep this unit in good working condition. The unit should be kept clean and free of debris. An air conditioner should be level and plant growth kept at least eighteen inches away to allow for proper ventilation. Air Conditioners can be damaged if operated in temperatures below 60 degrees or immediately after a cold night see our agreement. Additionally, some units have built-in heaters and can be damaged if operated before power has been restored for hours. Repair insulation on the suctions lines to the air conditioner. Airflow throughout the house may be balanced by adjusting any dampers in the supply ducts, or by adjusting the supply registers. Each room should have its own heat source. All visible rooms did appear to have a heat source. There will be normal temperature variations from room to room and level to level, most noticeable between levels. There were stains on the duct work under the dryer vent, replace the dryer vent and monitor. Page 12 of 14

14 The disposable filter should be replaced on a regular basis to maintain the efficiency of the system. The efficiency rating is not within the scope of this inspection. The humidifier did appear to be functional. A humidifier should be cleaned on a regular basis. Page 13 of 14

15 SUMMARY: The purpose of this summary is to provide a "quick view" of the results of the home inspection. Please be sure to read the full body of the inspection report, as it contains much more detail about your new home. Any recommendations for additional evaluation must be performed prior to the conclusion of the inspection contingency period. The following is a summary of the inspection performed at 5432 First St, Hometown, MI 48100: HELPFUL INFORMATION The shingles are nearing the end of their useful life-budget for new shingles. There were stains on the duct work under the dryer vent, replace the dryer vent and monitor. MAINTENANCE Flexible dryer vent hose was being used. Repair insulation on the suctions lines to the air conditioner. Paint was needed on several areas of the wood trim and the front wood shake siding. As a safety precaution, above ground decks and stairs should have guard rails and hand rails that are properly spaced and secure. There were a few loose rails that need to be secured. There were several nails sticking up from the deck boards, repairs are recommended. MINOR REPAIRS Gas lines need to be capped after a shut off valve or injury could occur. The window has a detached or broken tension spring, bar, or cable that should be repaired or replaced. There was rot to the wood sheathing on the left side of the roof, between the chimney and the garage. Extension cords should not be used for any purpose other than as a temporary power source. Permanent approved wiring is advised in place of extension cords to any permanently installed electrical component. Two of the family room windows do not open. Cracks and settlement were noted in the driveway. There was settlement where the driveway and garage floor meet, this is a trip hazard. SAFETY CONCERNS There is a strong gas odor at the gas logs. Page 14 of 14