1 4.16 FIRE & SOUND MANUAL ARCHITECT VERSION NOTE REGARDING CANADIAN PROJECTS: Canada accepts all UL Fire Designs listed in this manual. For additional information on Canadian Fire Designs, refer to page 12. DISCLAIMER: For complete assembly information for a specific fire design, click on the UL number or visit Underwriters Laboratories website. While the assemblies of the sound tests were constructed to best represent the most commonly built version of the UL fire design, some variances in construction may have occurred (i.e. within a particular UL rating there can be the allowances for different joist spacing and joist depths, different thicknesses and types of insulation or even no insulation, different types of channel, etc). The sound tests are a representation of what can be expected for sound control ratings when building a floor/ceiling assembly with a specific floor joist assembly that relates to a UL fire design using the designated sound control mat. However, due to the many variables beyond our control (for example quality control of drywall installation, type of resilient channel, density and selection of other building materials, flanking paths, etc.), the sound tests in this resource should not be considered a guarantee of performance. For this same reasoning and the fact that the sound tests were run in different buildings, different laboratories, and different environments, this data can be used for comparison and design evaluation but should not be considered a guarantee of performance. All acoustical testing was done by Architectural Testing; Riverbank Testing Laboratories; Intest, Inc.; Intertek Laboratories; Twin City Testing Corporation; D.L. Adams Associates, L.T.D.; Veneklasen Associates; Maxxon R&D Sound Chamber; NGC Testing Services; AV Group or JGL Acoustics. For assistance determining the right system and UL Fire Rating for your project, contact your Maxxon Regional Representative at (800)

2 PARALLEL CHORD TRUSS 1 HOUR FIRE DESIGNS Min. Truss Depth per UL Min. Topping Depth Sound Mat Floor Covering Fire Ratings 3/4" (19 mm) None Acousti-Mat I Carpet & Pad None 57 STC TL IIC IN A-STC A F-IIC A Vinyl 51 F-IIC A " Yes Yes HP None 59 F-STC STC Tile 51 F-IIC F Vinyl Plank 52 F-IIC F None 61 F-STC STC Tile 54 F-IIC F Vinyl Plank 54 F-IIC F None 62 F-STC STC Carpet & Pad 83 F-IIC Tile 54 F-IIC F L528 L546 L563 L574 L576 L579 L592 M508 ICC ESR # 2540 UL ER # Vinyl 54 F-IIC F None 62 F-STC STC HP Tile 58 F-IIC F Vinyl Plank 59 F-IIC F None 60 F-STC A Acousti-Mat LPR Tile 52 F-IIC A Vinyl 50 F-IIC A /4" (19 mm) Engineered Wood 56 F-IIC A None 54 A-STC A " Yes Yes Acousti-Mat I Vinyl 50 F-IIC A Ceramic Tile 50 F-IIC A Floating Laminate Wood Floor 50 F-IIC A None 60 A-STC Vinyl 53 F-IIC Laminate Wood 55 F-IIC Tile 54 F-IIC VCT 52 F-IIC Quarry Tile 58 STC NGC Quarry Tile 59 IIC NGC Vinyl 55 IIC NGC L528 L546 L558 L562 L563 L574 L576 L579 L585 L592 M503 M508 ICC ESR # 2540 UL ER # Floating Wood 57 IIC NGC Glue Down Wood 57 IIC NGC Tile 58 STC NGC (38 mm) Acousti-Mat 3 Tile 60 IIC NGC Oak Wood 58 IIC NGC Vinyl 58 IIC NGC Other Parallel Chord Truss ULs: For special assemblies and other burn ratings including 2 hr designs, additional Parallel Chord Truss UL exist. Refer to pages 11 & 12 for a list of these assemblies. The sound tests above are examples of the many sound tests we have on file. Please refer to the disclaimer on the cover of this guide. For assistance determining the right system and UL Fire Rating for your project, contact your Maxxon Regional Representative at (800)

3 I-JOIST 1 HOUR FIRE DESIGNS Min. Truss Depth per UL Min. Topping Depth Sound Mat Floor Covering Fire Ratings None 58 STC NGC HP Ceramic Tile 52 F-IIC Vinyl 53 F-IIC Cushioned Vinyl 53 F-IIC NGC None 61 STC NGC Luxury Vinyl Plank 57 IIC NGC L571 ICC ESR # 2540 ICC ESR # 1153 UL ER # None Carpet & Pad 58 STC TL IIC IN86-6 None 57 A-STC /2" Yes Yes 2 layers 1/2" or (2 x 13 or 16 mm) 3/4" (19 mm) Acousti-Mat LPR Acousti-Mat I Ceramic Tile 49 F-IIC a Vinyl Plank 47 F-IIC c None 58 F-STC Tile 53 F-IIC Vinyl Plank 52 F-IIC Tile Tile 60 F-STC F-IIC F-STC F-IIC L570 L589 M502 ICC ESR # 1141 ICC ESR # 1153 ICC ESR # 2540 WH # J UL ER # mm) Acousti-Mat 3 Tile 59 F-STC F-IIC Other I-Joist ULs: For special assemblies and other burn ratings, additional I-Joist UL exist. Refer to page 12 for a list of these assemblies. The sound tests above are examples of the many sound tests we have on file. Please refer to the disclaimer on the cover of this guide. For assistance determining the right system and UL Fire Rating for your project, contact your Maxxon Regional Representative at (800)

4 2X10 WOOD JOIST 1 HOUR FIRE DESIGNS Min. Truss Depth per UL 10" Yes Yes Min. Topping Depth Sound Mat Floor Covering 3/4" * (19 mm 25 mm) 3/4" (19 mm) None Carpet & Pad 79 F-IIC Acousti-Mat I Tile 52 STC CRT-001i 50 IIC CRT-001s None 60 STC D RO Tile 50 IIC CRT-001k Vinyl Plank 53 IIC CRT-001n Floating Wood 53 IIC CRT-001l Vinyl 52 IIC CRT-001m Ceramic Tile 59 STC TL IIC IN88-2 L502 L513 L515 L516 L520 L533 L545 L569 L593 M514 M518 M519 ICC ESR # 2450 UL ER # * Depending on UL Fire Design, sound tests were on 3/4", so ratings can apply to both depths. Other 2x10 ULs: For special assemblies and other burn ratings including 2 hr designs, additional 2x10 Wood Joist UL exist. Refer to pages 11 & 12 for a list of these assemblies. The sound tests above are examples of the many sound tests we have on file. Please refer to the disclaimer on the cover of this guide. For assistance determining the right system and UL Fire Rating for your project, contact your Maxxon Regional Representative at (800) OLD TIMBER Truss/Joists Dimensional Lumber No No n/a Min. Topping Depth Sound Mat Floor Covering n/a None None (38 mm) 2" concrete (51 mm) Acousti-Mat 3 Acousti-Mat 3 & Acousti-Mat 30 F-STC F-IIC Quarry Tile 47 F-STC Mannington Engineered Wood Floor Over Quiet Walk Pad 52 F-IIC Vinyl 46 F-IIC Cementitious Overlayment 52 F-STC 51 F-IIC Acousti-Mat 3 HP Exposed Concrete 47 F-IIC D The sound tests above are examples of the many sound tests we have on file. Please refer to the disclaimer on the cover of this guide. For assistance determining the right system for your project, contact your Maxxon Regional Representative at (800)

5 COMPOSITE STEEL/ CONCRETE FLOOR CEILING ASSEMBLIES Concrete Depth Ceiling Min. Topping Depth Sound Mat Floor Covering 3 1 2" Concrete over Steel Deck No Hat Attached to Joist None None None 57 STC 28 IIC TL , IN " Lightweight over Steel Deck Wire Hung Grid " Airspace Deck to Ceiling 2" HP Eng Wood on Ecore F-STC 66 F-IIC F14-889, -888 HP Carpet and Pad 70 F-STC 77 F-IIC F14-893, -890 HP Tile on Ecore F-STC 65 F-IIC F14-895, -894 G561 3" Concrete over 9/16" Corrugated Steel Deck Yes Wire Hung Grid " Airspace Deck to Ceiling Ceiling Tile None None None 55 STC 47 IIC CRT None Acousti-Mat LP Eng Wood 55 STC 64 IIC CRT None Acousti-Mat LP Eng Wood 54 STC 62 IIC CRT " Lightweight Concrete over Steel Deck Wire Hung Grid 34" Airspace Deck to Ceiling None Acousti-Mat LP Tile 66 F-IIC NAC Centerpoint 3/8" Acousti-Mat LP Eng Wood 64 F-IIC NAC Centerpoint Eng Wood 64 F-IIC NAC Centerpoint D502 Other Composite Steel/Concrete Floor assemblies ULs: For special assemblies and other burn ratings including 2 hour designs, additional Composite Steel/Concrete Floor assemblies UL exist. Refer to pages 11 and 12 for a list of these assemblies. The sound tests above are examples of the many sound tests we have on file. Please refer to the disclaimer on the cover of this guide. For assistance determining the right system for your project, contact your Maxxon Regional Representative at (800)

6 STEEL JOIST/PLYWOOD SUBFLOOR 1 HOUR FIRE DESIGNS Subfloor Min. Topping Depth Sound Mat Floor Covering 3/4" (19 mm) None Carpet & Pad 51 F-STC F-IIC Vinyl Tile 49 F-IIC None 58 F-STC CRA-iSpan Acousti-Mat I Wood 54 F-IIC CRA-iSpan Tile 49 F-IIC CRA-iSpan 3/4" T&G Plywood Yes Yes Vinyl 53 F-IIC CRA-iSpan None 59 F-STC CRA-iSpan Wood 53 F-IIC CRA-iSpan Tile 49 F-IIC CRA-iSpan Vinyl 52 F-IIC CRA-iSpan L564 L565 L567 M507 M513 Ceramic Tile 55 F-IIC FIIC (38 mm) Acousti-Mat 3 Ceramic Tile 57 F-IIC FIIC Vinyl 57 F-IIC FIIC Wood 58 F-IIC FIIC layers (2 x 16 mm) Tile 56 F-IIC Carpet & Pad 71 F-IIC The sound tests above are examples of the many sound tests we have on file. Please refer to the disclaimer on the cover of this guide. For assistance determining the right system and UL Fire Rating for your project, contact your Maxxon Regional Representative at (800)

7 STEEL JOIST/CORRUGATED STEEL DECK 1 AND 2 HOUR FIRE DESIGNS Subfloor Suspended Min. Topping Depth Sound Mat Floor Covering Fire Ratings 9/16" (14 mm) to top of flutes, over top of flutes None Acousti-Mat LPR Carpet & Pad Ceramic Tile 56 STC NGC IIC NGC STC NGC IIC NGC None 60 F-STC AO Yes Yes No 9/16" (14 mm) to top of flutes, over top of flutes VCT 57 F-IIC A None 60 F-STC A VCT 56 F-IIC A None 60 F-STC A VCT 56 F-IIC A None 59 F-STC A layers (2 x 16 mm) VCT 49 F-IIC A Floating Wood 57 F-IIC A Corrugated Steel Deck Yes Yes No (38 mm) Acousti-Mat SD Ceramic Tile 51 F-IIC A Vinyl 55 F-IIC A Carpet & Pad 83 F-IIC A None 57 F-STC A VCT 48 F-IIC A Floating Wood 55 F-IIC A Ceramic Tile 51 F-IIC A Vinyl 52 F-IIC A G551* G553* G560* G563* G566* G574* G587 G597 M511 ICC ESR # 2540* UL ER # * Carpet & Pad 76 IIC A Tile 56 F-STC NGC Tile 51 IIC NGC /16" (14 mm) to top of flutes, over top of flutes Vinyl 52 IIC NGC None 61 F-STC AO VCT 57 F-IIC AO None 57 F-STC A Yes No Yes VCT 51 F-IIC A (38 mm) Acousti-Mat SD Floating Wood 54 F-IIC A Ceramic Tile 51 F-IIC A Vinyl 53 F-IIC A Carpet & Pad 73 F-IIC A * See UL for specific design detail difference between ratings. The sound tests above are examples of the many sound tests we have on file. Please refer to the disclaimer on the cover of this guide. For assistance determining the right system and UL Fire Rating for your project, contact your Maxxon Regional Representative at (800)

8 HAMBRO SYSTEMS 1, 1 1 2, AND 2 HOUR FIRE DESIGNS Subfloor Min. Topping Depth Sound Mat Floor Covering Hambro No 1/2" (13 mm) None None None 32 IIC NGC Quarry Tile 54 STC NGC IIC NGC Sheet Vinyl 53 IIC NGC Floating Wood Laminate 55 IIC NGC Engineered Hardwood 51 IIC NGC G524* * See UL for specific design detail difference between ratings. The sound tests above are examples of the many sound tests we have on file. Please refer to the disclaimer on the cover of this guide. For assistance determining the right system and UL Fire Rating for your project, contact your Maxxon Regional Representative at (800)

9 PRECAST CONCRETE 1, 2, AND 3 HOUR FIRE DESIGNS Concrete Depth 4" No No No None 6" Yes Yes Yes 8" Suspended Ceiling Min. Topping Depth Sound Mat Floor Covering No No No None Yes Yes Yes 1-1/4" Mortar Bed (32 mm) 1/2" (13 mm) 3/4" (19 mm) Cement Board 1-1/4" Mortar Bed (32 mm) None Acousti-Mat LPR Acousti-Mat I Marble Tile Ceramic Tile 55 STC TL IIC IN STC TL IIC IN98-12 None 58 F-STC Carpet Direct 75 F-IIC Tile 55 F-IIC B Vinyl Plank 53 F-IIC B Engineered Wood 55 F-IIC B Tile 54 F-IIC B Vinyl Plank 56 F-IIC B Engineered Wood 54 F-IIC B None 61 F-STC B Tile 59 F-IIC B Vinyl Plank 57 F-IIC B Tile 61 F-IIC B Vinyl Plank 57 F-IIC B Engineered Wood 61 F-IIC B Ceramic Tile Ceramic Tile Vinyl 2 Layers of Plywood T&G Oak Flooring 59 STC TL IIC IN STC TL IIC IN STC TL IIC IN STC TL IIC IN STC TL IIC IN 82-7 Fire Ratings J917* J919* J920* J924* J927* J931* J957* J958* J991* J994* ICC ESR # 2540* UL ER # * * See UL for specific design detail difference between ratings. The sound tests above are examples of the many sound tests we have on file. Please refer to the disclaimer on the cover of this guide. For assistance determining the right system and UL Fire Rating for your project, contact your Maxxon Regional Representative at (800)

10 CONCRETE 1, 2, AND 3 HOUR FIRE DESIGNS Concrete Depth Suspended Ceiling Min. Topping Depth Sound Mat Floor Covering 4" No No No None Concrete Micro-Topping 50 F-IIC J804* (38 mm) Acousti-Mat 3 Concrete Micro-Topping 59 F-IIC J805* 8" No No No None No No Yes No No Yes n/a None None 61 A-STC F F-IIC F /4" (19 mm) Acousti-Mat LPR Cementitious Overlayment 55 F-IIC F /2 Concrete (64 mm) Armstrong Vinyl Tile 62 F-STC F-IIC Bruce Engineered Hardwood 60 F-IIC Ceramic Tile 61 F-IIC None 55 F-IIC Ceramic Tile 65 F-IIC (38 mm) 2" Concrete (51 mm) Acousti-Mat 3 n/a None None 1/2" (13 mm) Acousti-Mat LP Ceramic Tile 70 F-IIC None 61 F-IIC A-STC F-IIC None 57 F-IIC Glue Down 3/4" Wood 60 F-IIC Ceramic Tile 54 F-IIC Tile 60 F-IIC Tile 66 F-IIC (38 mm) Acousti-Mat 3 Tile 74 F-IIC * See UL for specific design detail difference between ratings. ** over 6"+ concrete do not require gypsum concrete. The sound tests above are examples of the many sound tests we have on file. Please refer to the disclaimer on the cover of this guide. For assistance determining the right system and UL Fire Rating for your project, contact your Maxxon Regional Representative at (800) n/a**

11 2 HOUR WOOD FRAME FIRE DESIGNS PARALLEL CHORD TRUSS Canada also accepts all UL Fire Designs listed in this manual. Min Truss Direct Depth per UL to Joist Min. Topping Depth Sound Mat Floor Covering 12" Yes Yes 2 Layers (2x16 mm) (38 mm) Acousti-Mat 3 None 59 F-STC STC Acousti-Mat 3 Tile 53 F-IIC Acousti-Mat 3 Vinyl Plank 53 F-IIC L577 I-JOIST Min Truss Depth per UL Direct to Joist Min. Topping Depth Sound Mat Floor Covering 9-1/2" Yes Yes 2 Layers (2x16 mm) HP None 56 F-STC STC HP Tile 48 F-IIC HP Vinyl Plank 48 F-IIC ICC ESR # 1153 The sound tests above are examples of the many sound tests we have on file. Please refer to the disclaimer on the cover of this guide. For assistance determining the right system and UL Fire Rating for your project, contact your Maxxon Regional Representative at (800)

12 MISCELLANEOUS UL FIRE DESIGNS PARALLEL CHORD TRUSS UL # Unique Assembly Details L529 Suspended Ceiling L542 Furring s/ Screwed Direct L556 2HR/4 Layers of L577 2HR/3 Layers of L581 Kinetics ICW Clip, Batt, 2 Layers Gypsum Board L583 Kinetics Isomax Clip, Batt, 2 Layers of Gypsum Board M Layers of M510 3 Layers of - 1 Layer Screwed Direct 2X10 UL # Unique Assembly Details M HR/ Screwed Direct M514 Sound Break Gypsum Board from National Gypsum L581 Kinetics ICW Clip, Batt, 2 Layers Gypsum Board L583 Kinetics Isomax Clip, Batt, 2 Layers of Gypsum Board I-JOIST UL # Unique Assembly Details L518 TJL / L530 TJI /Simpson Strong Clips L538 2HR/3 Layers of L547 TJI / L556 Wilamette I Beam Truss/4 Layers of L581 Kinetics ICW Clip, Batt, 2 Layers Gypsum Board L583 Kinetics Isomax Clip, Batt, 2 Layers of Gypsum Board STEEL JOIST UL # Steel Joist Manufacturer G230 2HR/Midcon MetalEdge concrete T&G plank G516 2HR/Midcon MetalEdge concrete T&G plank ULC DESIGN # Hour Rating Type of Construction I , 2 TotalJoist by ispan L " x 10" Wood Joist L " x 10" Wood Joist L " x 10" Wood Joist L " x 10" Wood Joist (Commercial Construction Only) M " x 10" Wood Joist M " x 10" Wood Joist M " x 10" Wood Joist M514 2 Parallel Chord Truss or Steel Frame M520 1 TotalJoist by ispan M521 1 TotalJoist by ispan Canada also accepts all UL Fire Designs listed in this manual. For verification of a UL Fire Design for Canada, refer to the UL Environment document CCOX7.R8477 Floor- and Roof-topping Mixtures Certified for Canada, which can be obtained by contacting your Maxxon Regional Representative or at For assistance determining the right systems and UL Fire Rating for your project, contact your Maxxon Regional Representative at (800) Underwriters Laboratories Inc. Listed For more info: info@maxxon.com Another superior product from: Maxxon Corporation 920 Hamel Road P.O. Box 253 Hamel, MN USA Fax: Maxxon Corporation. All Rights Reserved. Gyp-Crete, Gyp-Crete 2000/3.2K, Dura-Cap, Commercial Topping, Therma-Floor, Level-Right, Acousti-Mat and associated logos are registered trademarks of Maxxon Corporation, Hamel, MN, USA. TJI Joists are manufactured by and are registered trademarks of Trus Joist MacMillan. Thermafiber, Sheetrock and Firecode C are trademarks of US Gypsum Company. is a trademark of Bonar. SpaceJoist is a registered trademark of Truswal Systems Corporation. TotalJoist by ispan is a trademark of Genesis TP. Printed in the USA. #82005, TA , 4/ MADE IN THE USA