1 136 Lighpaths Fiber Protection System, ducting, or raceway is the ideal system for routing and protecting cables routed through exchanges, central offices, CATV headends, data centers, collocation sights, hubs, shelters, nodes, and customer premises. Lighpaths maintains a 2 bend radius throughout the system. Lighpaths is the only Halogen-free system on the market, and the only system that exceeds Telcordia GR-63 NEBS requirements as tested by an independent third party test lab. Mounting Hardware The parts connecting the Lighpaths system do not require mounting hardware. No other system on the market can make this claim. Parts are assembled in seconds with the new patented slide-on-joiner. Vertical drops can be added in less than 5 minutes by snapping them in place with no mounting hardware required. Drops exit the side of the raceway in order to not interfere with overhead ladder racking. Lighpaths is available in all popular sizes to accommodate virtually any application. Available Services Mounting kits are available to affix the ducting to the ladder racking, threaded rod, cabinets, racks, and wall. Technical application assistance and field support is provided to end-users, installers, and contractors. Installation services and engineering services are also available. Typical Installations Colocation Sites or Central Offices CATV Headends or Data Centers Customer Premises, Hubs, or Shelters Fiber Frame Management Standards ISO 9001 Certified Quality Management System by NCS International Fire retardant plastic, Halogen Free, UL94-VO rated UL2024A standard EEU - ROHS requirements

2 137 Capacity Raceway Max Patchcord Capacity (3.0 mm OD) 2 x2 (50mm x 50mm) 4 x4 (100mm x 100mm) 4 x8 (100mm x 200mm) x12 (100mm x 300mm) Solid Straight Sections Solid straight sections are used for horizontal routes. Standard length is 2 meters (6.5 feet). Lids are hinged, providing easy accessibility. Body Part Number Cover Part Number 2 x2 (50mm x 50mm) TC TC x4 (100mm x 100mm) TC NS TC TC NS TC x12 (100mm x 300mm) TC NS TC Slotted Straight Sections Slotted straight sections are used for vertical routes bringing cables to equipment in racks or cabinets. Slot trumpets provide bend radius protection (order separate). 2 x2 (50mm x 50mm) (includes mounting hardware & short lid) Slot trumpets (can be used with any slotted straight section)(10 per bag) Part Number TC SLAKit TC Slot Trumpets provide the proper bend radius for cables exiting

3 138 Horizontal Tees & Covers Horizontal Tees are used to change directions perpendicular to the main route. Tees can also tee-off in a different size (i.e. 4 x 8 to 4 x 4 ). Use tees at corners where horizontal routes may continue. Body Part Number Cover Part Number 2 x2 (50mm x 50mm) TC A Supplied with body 4 x4 (100mm x 100mm) TC NS TC TC NS TC x12 (100mm x 300mm) TC NS TC Horizontal Crosses & Covers Horizontal Crosses are used to change directions perpendicular to the main route. Body Part Number Cover Part Number 2 x2 (50mm x 50mm) TC A Supplied with body 4 x4 (100mm x 100mm) TC TC TC TC x12 (100mm x 300mm) TC TC L

4 139 Horizontal Elbows & Covers Horizontal Elbows are used to change directions perpendicular to the main route. Elbows are ideal for use at corners where horizontal routes will not continue. 30, 45, and 90 degree elbows are available. Angle Body Part Number Cover Part Number 30 Degree 2 x2 (50mm x 50mm) TC A Supplied with Body 30 Degree 4 x4 (100mm x 100mm) TC TC Degree TC TC Degree 2 x2 (50mm x 50mm) TC A Supplied with Body 45 Degree 4 x4 (100mm x 100mm) TC TC Degree TC TC Degree 4 x12 (100mm x 300mm) TC TC Degree 2 x2 (50mm x 50mm) TC A Supplied with Body 90 Degree 4 x4 (100mm x 100mm) TC TC Degree TC TC End Caps End Caps are used to close the end of a horizontal or vertical route. Some end caps are used with tubing to drop cables into frames or cabinets. 2 x2 (50mm x 50mm) 4 x4 (100mm x 100mm) 4 x4 (100mm x 100mm), with 2 ea 5 feet length tubes 4 x12 (100mm x 300mm) Body Part Number TC D TC TC B2Kit TC TC

5 140 Vertical Elbows & Covers Vertical Elbows are used to change directions upward or downward to avoid obstacles. 45 and 90 degree elbows are available in most sizes. Retro elbows are supplied with a slit in the body to permit entrance of existing cables without the need to disconnect. Vertical Elbow Retro Elbow Type and Angle Body Part Number Cover Part Number Elbow Up 45 Degree 2 x2 (50mm x 50mm) TC A Supplied with Body Elbow Up 45 Degree 4 x4 (100mm x 100mm) TC A Supplied with Body Elbow Up 45 Degree TC A Supplied with Body Elbow Up 45 Degree 4 x12 (100mm x 300mm) TC TC Elbow Up 90 Degree 2 x2 (50mm x 50mm) TC A Supplied with Body Elbow Up 90 Degree 4 x4 (100mm x 100mm) TC A Supplied with Body Elbow Up 90 Degree TC A Supplied with Body Elbow Up 90 Degree 4 x12 (100mm x 300mm) TC TC A Elbow Down 45 Degree 2 x2 (50mm x 50mm) TC A Supplied with Body Elbow Down 45 Degree 4 x4 (100mm x 100mm) TC A Supplied with Body Elbow Down 45 Degree TC A Supplied with Body Elbow Down 45 Degree 4 x12 (100mm x 300mm) TC TC L Elbow Down 90 Degree 2 x2 (50mm x 50mm) TC A Supplied with Body Elbow Down 90 Degree 4 x4 (100mm x 100mm) TC A Supplied with Body Elbow Down 90 Degree TC A Supplied with Body Elbow Down 90 Degree 4 x12 (100mm x 300mm) TC A TC A Retro Elbow Down 90 Degree 4 x4 (100mm x 100mm) TC R Supplied with Body Retro Elbow Down 90 Degree TC R Supplied with Body Retro Elbow Up 90 Degree 4 x4 (100mm x 100mm) TC R Supplied with Body Retro Elbow Up 90 Degree TC R Supplied with Body

6 141 Flared Trumpets Flared Trumpets are used to ensure proper bend radius for cables exiting vertically from the horizontal route. 2 x2 (50mm x 50mm) 4 x4 (100mm x 100mm) Body and Cover Part Number TC A TC A TC R Downspouts Downspouts are typically used for adding drops to an existing horizontal route. By exiting the side of the system, interference with ladder racking and other objects, typically mounted above the horizontal raceway, is avoided. To use the downspout to add drops, a quick punch-out is made in the side wall, and a bend-radius ramp and downspout are snapped into place in a few seconds. 2 x2 (50mm x 50mm) Punch Tool 4 x4 (100mm x 100mm) Punch Tool 2 x2 (50mm x 50mm) Downspout 4 x4 (100mm x 100mm) Downspout Kit Part Number TC TC A TC KIT TC KIT

7 142 Pre-assembled Downspouts Pre-assembled Downspouts are horizontal tees with vertical downspouts. By exiting the side of the system, interference with ladder racking and other objects, typically mounted above the horizontal raceway, is avoided. Kits can be supplied with downspouts preassembled on one or both sides of short straight section. To use the downspout to add drops, just assemble to a slide-on joiner which takes seconds. 4 x4 (100mm x 100mm) with 4 x4 drop 4 x4 (100mm x 100mm) with 2 x2 drop with 4 x4 drop with 2 x2 drop 4 x12 (100mm x 300mm) with 4 x4 drop Body and Cover Part Number TC1279-4DROP-4 TC1279-2DROP-4 TC1279-4DROP-8 TC1279-2DROP-8 TC1279-4DROP-12 Vertical Tees & Covers Vertical Tees are used to drop cables vertically from horizontal routes into frames or cabinets directly underneath raceway. Vertical Tees have cable dividers. Retro Tees are supplied with a slit in the body to permit entrance of existing cables without the need to disconnect. Type Drop Body Part Number Cover Part Number Vertical Tee 2 x2 (50mm x 50mm) 2 x2 TC A Supplied with Body Vertical Tee 4 x4 (100mm x 100mm) 4 x4 TC TC Vertical Tee 4 x4 TC TC Vertical Tee 4 x12 (100mm x 300mm) 4 x8 TC TC Retro Tee 4 x4 (100mm x 100mm) 4 x4 TC R Supplied with Body Retro Tee 4 x4 TC R Supplied with Body

8 143 Joiners/Junctions Joiners are used to connect two parts together, and slide on to parts with no tooling or hardware required. Joiners connect in seconds. 1/4 turn locks parts together. 2 x2 (50mm x 50mm) 4 x4 (100mm x 100mm) 4 x12 (100mm x 300mm) Part Number TC TC A TC A TC A Lightpaths to ADC Adapter kits Adapters and Reducers are used to connect parts of different sizes or brands. 100mm x 100mm to 100mm x 200mm 4 x 4-4 x 8 left 100mm x 100mm to 100mm x 200mm 4 x 4-4 x 8 right 100mm x 200mm to 100mm x 300mm 4 x 8-4 x mm x 100mm to ADC 4 straight 4 x 4 - ADC 4 100mm x 100mm to ADC 4 horizontal tee 4 x 4 - ADC 4 100mm x 200mm to ADC 6 straight 4 x 8 - ADC 6 100mm x 200mm to ADC 6 straight 4 x 8 - ADC 6 100mm x 200mm to ADC 6 horizontal tee 4 x 8 - ADC 6 Body and Cover Part Number TC A TC A TC A TC KIT TC KIT TC KIT TC KIT TC KIT

9 144 Storage Spools Storage Spools are used to store excess cable slack up in the ducting system where it is safe from mishandling and potential damage. In-line Spools can be placed within or at the end of a horizontal run. Spools are ideal for under-floor slack cable storage in data centers. 2 x2 (50mm x 50mm) 4 x4 (100mm x 100mm) 4 x12 (100mm x 300mm) Part Number TC KIT (in-line) TC KIT (in-line) TC KIT (in-line) TC K (under floor) TC K (under floor) Mounting Hardware Mounting Hardware is available for virtually any kind of installation. Kits are available for mounting to ladder racking, threaded rod, wall mounting, and under floor pedestal mounting. Under Floor Mount Trapeze Mount Ladder Rack Mount Mounting Kit Style Part Number 2 x2 (50mm x 50mm) Ladder Rack TC KIT 2 x2 (50mm x 50mm) Cabinet Mount TC KIT 2 x2 (50mm x 50mm) Wall Mount TC KIT 4 x4 (100mm x 100mm) Ladder Rack TC KIT 4 x4 (100mm x 100mm) Threaded Rod 1/2 inch existing TC KITC-1 4 x4 (100mm x 100mm) Threaded Rod 5/8 inch existing TC KITD-1 4 x4 (100mm x 100mm) Under Floor Pedestal Mount TC KITA 4 x4 (100mm x 100mm) Wall Mount TC KIT Ladder Rack TC KIT Threaded Rod 1/2 inch existing TC KITC-2 Threaded Rod 5/8 inch existing TC KITD-2 Under Floor Pedestal Mount TC KITA Wall Mount TC KIT 4 x12 (50mm x 300mm) Trapeze Kit Threaded Rod 1/2 inch existing TC BKIT 4 x12 (50mm x 300mm) Trapeze Kit Threaded Rod 5/8 inch existing TC DKIT Threaded Rod Mount