GCP APPLIED TECHNOLOGIES PERM-A-BARRIER VPL 50

Size: px
Start display at page:

Download "GCP APPLIED TECHNOLOGIES PERM-A-BARRIER VPL 50"

Transcription

1 MASONRY ANCHOR DETAILING:. GASKETED STANDOFF ANCHOR 0 MIN.. SURFACE MOUNTED ANCHOR " MIN LADDER STYLE ANCHOR.. MASONRY ANCHOR DETAILING. S00, -INCH TROWELED BEAD. MORTAR COLLECTION MESH. PERM-A-BARRIER WALL FLASHING, PRIME SUBSTRATE WHERE REQUIRED. SHEET METAL FLASHING PER ARCH 7. CONTINUOUS SHELF ANGLE SUPPORT PER STRUCTURAL. S00 SEALANT 9. MASONRY WEEP/VENT 0. GASKETED WASHER. Detail not suitable for all climates. Avoiding excessive moisture accumulation in exterior walls is dependent on many factors including proper. Install all GCP products in accordance with GCP Product Data Sheets and GCP recommendations. CONTINUOUS MASONRY SHELF ANGLE SUPPORT (SECTION) DRAWING: VPL0-00 SCALE: = ' EFFECTIVE DATE: 07..

2 . S00, -INCH TROWELED BEAD.. CLADDING ATTACHMENT, DETAIL PER GCPAT REQUIREMENTS. JOINT TREATMENT PER DRAWING ISO 00-B. Detail not suitable for all climates. Avoiding excessive moisture accumulation in exterior walls is dependent on many factors including proper INSIDE CORNER DETAIL (PLAN) DRAWING: VPL0-00 SCALE: = ' EFFECTIVE DATE: 07.. SUPERCEDES: NEW

3 . PERM-A-BARRIER DETAIL MEMBRANE, NPS DETAIL MEMBRANE, ALUMINUM FLASHING, OR WALL FLASHING. PRIME SUBSTRATE WHERE REQUIRED.. CLADDING ATTACHMENT, DETAIL PER GCPAT REQUIREMENTS. JOINT TREATMENT PER DRAWING ISO 00-B. Detail not suitable for all climates. Avoiding excessive moisture accumulation in exterior walls is dependent on many factors including proper. For CMU and cast in place concrete construction, sheet flashing at outside corner may be considered optional provided substrate allows for a continuous 0 dry mil VPL0 application. OUTSIDE CORNER DETAIL (PLAN) DRAWING: VPL0-00 SCALE: = ' EFFECTIVE DATE: 07.. SUPERCEDES: NEW

4 ".. CLADDING ATTACHMENT, CONFIRM DETAILING REQUIREMENTS WITH THE GCPAT REPRESENTATIVE. S00, -INCH TROWELED BEAD. PERM-A-BARRIER WALL FLASHING, PRIME SUBSTRATE WHERE REQUIRED. SHEET METAL FLASHING PER ARCH. TERMINATION PER HORIZONTAL WATERPROOFING SYSTEM MANUFACTURER 7. HORIZONTAL WATERPROOFING SYSTEM - SEE GCPAT.COM 7 ". Detail not suitable for all climates. Avoiding excessive moisture accumulation in exterior walls is dependent on many factors including proper BASE OF WALL DETAIL (SECTION) DRAWING: VPL0-00 SCALE: = ' EFFECTIVE DATE: 07.. SUPERCEDES: NEW

5 .. CLADDING ATTACHMENT, CONFIRM DETAILING REQUIREMENTS WITH THE GCPAT REPRESENTATIVE. S00, -INCH TROWELED BEAD. SHEET METAL FLASHING PER ARCH. S00, FLASHING AND CANT SEAL. AIR AND WATER TIGHT BOX PENETRATION 7. AIR AND WATER TIGHT PIPE PENETRATION. POLYURETHANE SEALANT OR NON-SHRINK GROUT PER BACKUP WALL TYPE 9. JOINT TREATMENT PER DETAIL ISO 00-B " " Detail not suitable for all climates. Avoiding excessive moisture accumulation in exterior walls is dependent on many factors including proper VPL 0 PENETRATION DETAILING DRAWING: VPL0-00 SCALE: = ' EFFECTIVE DATE: 07..

6 STEP : STEP :. SHEATHING SUBSTRATE. PERM-A-BARRIER DETAIL MEMBRANE, NPS DETAIL MEMBRANE, ALUMINUM FLASHING, OR WALL FLASHING. PRIME SUBSTRATE WHERE REQUIRED. JOINT TREATMENT PER DETAIL VPL S00, -INCH TROWELED BEAD. VPL 0 MEMBRANE. WINDOW PER ARCH 7. SHEET METAL HEAD FLASHING PER ARCH. STEP : STEP : 7. Detail not suitable for all climates. Avoiding excessive moisture accumulation in exterior walls is dependent on many factors including proper. Refer to detail VPL0-00-B for sheet flashing sequence. WINDOW FLASHING SEQUENCE 0-A DRAWING: VPL0-00-A SCALE: NOT TO SCALE EFFECTIVE DATE: 07..

7 WINDOW PRESTRIP VARIATIONS: A. WITHOUT BACK DAM ANGLE: B. WITH BACK DAM ANGLE: WINDOW PRESTRIP: PERM-A-BARRIER DETAIL MEMBRANE, NPS DETAIL MEMBRANE, ALUMINUM FLASHING, OR WALL FLASHING. PRIME SUBSTRATE WHERE REQUIRED STEP STEP OPTION B SILL PRESTRIP CORNER DETAILING: STEP STEP C D B E A TYPICAL SILL PRESTRIP CORNER DETAILING AT METAL BACK DAM ANGLE. SEE BELOW FOR FOLDING TEMPLATE. BACK DAM ANGLE HEIGHT PER ARCH LAP BACK FLAP OF SILL CORNER PIECE O/ END DAM C D BACK DAM ANGLE HEIGHT PER ARCH V.I.F. " MIN. B A CUT LINES SHOWN DASHED FOLD LINES SHOWN SOLID V.I.F. STEP STEP " E CORNER PATCH INSTALLED O/ BOTTOM CORNERS OF SILL FLASHING. PRESS INTO CORNER TO CREATE TIGHT SEAL AND PREVENT PATCH FROM BRIDGING AT ALL 90 DEGREE SUBSTRATE ANGLE CHANGES.. Detail not suitable for all climates. Avoiding excessive moisture accumulation in exterior walls is dependent on many factors including proper. Terminate all edges, cuts, and laps that are not water-shedding in orientation including on the horizontal of the sill with Perm-a-Barrier S00 Sealant. WINDOW FLASHING SEQUENCE 0-B DRAWING: VPL0-00-B SCALE: NOT TO SCALE EFFECTIVE DATE: 07..

8 STEP : STEP :. SHEATHING SUBSTRATE. PERM-A-BARRIER PRIMER AT ALL EXPOSED GYPSUM SHEATHING EDGES. JOINT TREATMENT PER DETAIL VPL S00 AT ALL TRANSITIONS BETWEEN FRAMING AND SHEATHING. S00 MUST BE TACK FREE PRIOR TO STEP. 0 MIL WET THICKNESS VPL 0 IN FIELD. MINIMUM MIL WET THICKNESS VPL 0 AT SILL, JAMBS, AND HEAD OF OPENING STEP :. Detail not suitable for all climates. Avoiding excessive moisture accumulation in exterior walls is dependent on many factors including proper. Refer to detail VPL0-00-B for sheet flashing sequence. WINDOW FLASHING SEQUENCE 0-C DRAWING: VPL0-00-C SCALE: NOT TO SCALE EFFECTIVE DATE: 07..

9 . VPL 0 MEMBRANE. PERM-A-BARRIER S00 SEALANT " " " ". Detail not suitable for all climates. Avoiding excessive moisture accumulation in exterior walls is dependent on many factors including proper TYPICAL VPL 0 JOINT TREATMENT DRAWING: VPL0-007 SCALE: NOT TO SCALE EFFECTIVE DATE: 07..