The most versatile "BIG SCREEN" high efficiency fireplace!

Size: px
Start display at page:

Download "The most versatile "BIG SCREEN" high efficiency fireplace!"

Transcription

1 ZERO CLEARANCE (ZC) The most versatile "BIG SCREEN" high efficiency fireplace! Endless opportunities True polyvalence Enjoy high efficiency fires or the cozy ambiance of open fires. BBQ cooking. Water heating. Ultramodern or classic appearance. With Don-Bar, all this is available! A The look of a real fireplace: The Don- Bar design, with its clean lines, eliminates the unattractive effect of the "prefabricated" box. It will fit in any classic or ultra-modern decor without never going out of fashion. An unmatched choice of dimensions: Don-Bar offers you the widest choice of models and sizes on the market. You will easily find the fireplace model that best suits your floor plan: single sided, two-sided (corner or see-through) and even three-sided! And several more extras: Compare and you'll agree that only Don-Bar can give you as much! re you dreaming of an elegant fireplace powerful enough to heat the whole house without overheating the room in which it is installed? This is exactly the goal achieved by Don-Bar with its latest ZC zero clearance fireplace fitted with its unique heat distribution system. Never a fireplace manufacturer has offered such a versatile product for auxiliary home heating. Power to spare: The high efficiency gas regulating system makes it possible to recover more heat from the wood consumed. In addition, the airtight door prevents heat loss through the chimney. A spectacular fire: With the extra-large self-cleaning ceramic glass door you can admire the spectacle of fire in all its splendor. Heat the air and... the water too! Install your fireplace in the basement and heat an upper floor or vice versa. Our unique warm air distribution system will do the job. Heat your domestic water or a radiant floor with our new hydronic system. Energy savings and comfort guaranteed! BBQ cooking! Thanks to our dual-mode heating system with its retractable high efficiency HE deflector you will be able to cook over an open fire without fear of smoke throughout the house. Laugh at the weather and impress your friends with succulent BBQ dishes year long! Choose between a classic or a contemporary look! Choose your own decoration style and our fireplace will fit perfectly: classic or ultra-modern or even art deco. The architectural flexibility of our ZC fireplace is unmatched! Don-Bar, 741 St-Vallier West, Quebec, QC G1N 1E2 - Tel: (418) Fax: (418) Web: don-bar@don-bar.com REV Copyright Les Foyers Don-Bar inc.

2 SELECTION MODEL Power kw/h Power B.T.U./h Heated surface in sq. ft. (average) Chimney outlet Maximum Logs Vision (sq. in.) / / / ,000 62,000 68,000 75, à 900 à 1000 à 1200 à "/8" (180/200) 7"/ 8" (180/200) 8" (200) 16" (405) 20 (508) 20" (508) 20" (508) Optional: BBQ Grill. Firescreen. Anti-smoke flap. Fans. DETAILS OF THE ASSEMBLY Factory-built chimney 2100 deg. 7 or 8 I.D. (180 or 200 mm) (not included) Raised base and fan details 24 82, à 3000 ) 24" (610) 650 Axial fans (2) to put under base (optional) Triple heating power! The engineers of Don-Bar have took advantage of 3 thermal principles to recover a maximum of heat from the wood. First, the retractable damper of the HE high efficiency system allows, in closed position, to raise the temperature of the fire at its maximum. Dual-mode high efficiency system Chimney anchor plate (not included) Don-Bar insulated case Thermodisc Speed control Electric cable with 120 V plug Rigid stainless chimney liner same diameter as the chimney (included) Open fire mode (damper open): Ideal for cozy fires with a firescreen or for cooking with the BBQ grill. Heating mode (damper closed): Reburn the gases for maximum heating power. Keep glass door and chimney clean. Next, the infrared radiation passing through the glass warms the immediate vicinity. Raised base Outside air intake (optional): 4" (100 mm) flexible insulated duct Don-Bar insert Double ventilated frame and joint cover (included) Finally, the residual heat around the insert is recirculated throughout the home by convection. Don-Bar, 741 St-Vallier West, Quebec, QC G1N 1E2 - Tel: (418) Fax: (418) Web: don-bar@don-bar.com REV Copyright Les Foyers Don-Bar inc.

3 INSTALLATION Multiple opportunities to heat the house For your comfort, the Don-Bar ZC fireplace offers a wide variety of opportunities to spread the heat in the house. Choose the option that best suits your needs. Note that the warm air distribution system is optional and its absence will not prevent your fireplace from working to perfection.. Heating duct to heat an upper floor by gravity (right, left or both sides, on the top of the insulated case.) Typical interior installation with warm air ducts heating an upper floor Round top Storm collar Roof Factory-built insulated chimney 2100 degrees Roof support Flashing Attic Attic radiation shield/firestop Note: Warm air ducts are optional Metal grilles Lower floor heating duct (at the right, left or behind the insulated case) Lower floor heating duct (preinstalled duct - left or right) Joist Metal duct 6" (150 mm) I.D. (flexible or rigid) insulated 1" (25 mm), or B-Vent duct Chimney anchor plate insulated case Rigid stainless liner 8" dia. (200 mm) Joist Radiant shield/ firestop The warm air ducts used to heat an upper floor by gravity shall rise as vertically as possible. Axial fans, 105, 245 or 438 cfm (to insert and secure inside the duct) insert Protection for combustible floor Optional fan Heating ducts must be made of metal, 6" (150 mm) I.D., with a 1" (25 mm) fiberglass insulating jacket finished with an aluminized covering. Don-Bar, 741 St-Vallier West, Quebec, QC G1N 1E2 - Tel: (418) Fax: (418) Web: don-bar@don-bar.com REV Copyright Les Foyers Don-Bar inc.

4 DIMENSIONS INSULATED CASE T *S finishing cover joint ventilated frame c 11 1/2 Typical interior fireplace framing Gypsum board or plywood or particle board mandatory behind the insulated case Chimney 2100 degrees Metal studs mandatory U Y R Non combustible board 1/2" (12 mm) (Durok) Optional: 2 axial fans of 5" (125 mm) under the raised base Heating duct air outlets X *Q 9" (230 mm) Durok Ventilated frame Ø 6 Ø 9 7 Durok 8" (200 mm) *Q c c 11 1/2 5 1/16 *S 13 1/16 Heating duct air outlet Ø 6 Outside air inlet Ø /8 Gypsum board 1/2" (12 mm) Protection for combustible floor 8" (203 mm) *Q 23-1/ / / / / / / / /8 638 R *S 37-1/ / / / / / / / / T 25-3/ / / / / / / /4 438 U / / / / / / X / / / / / Y 27-1/ / / / / / / mm mm mm mm mm mm mm mm mm *Q and *S - spacers included Don-Bar, 741 St-Vallier West, Quebec, QC G1N 1E2 - Tel: (418) Fax: (418) Web: don-bar@don-bar.com REV Copyright Les Foyers Don-Bar inc.

5 INSULATED EXTERIOR CHASING Construction details (for dimensions see next page) Insulated exterior chasing with a non covered chimney round top DANGER OF FIRE Never fill (stuff) with the empty spaces around the insulated case and around the insert. Insulated exterior chasing for a covered chimney roof support round top storm collar chimney flashing metal flashing wall bracket 2100 chimney 7" or 8" I.D. (180 ou 200 mm) offset to center the chimney 2100 chimney 7" or 8" I.D. (180 or 200 mm) roof flashing wall bracket roof support Maximum slope for flashing 12 4 roof support radiation shield/firestop 23" min. (585 mm) fiberglass MANDATORY: plywood, particle or gypsum boards fiberglass free space 17" min. (430 mm) radiation shield/firestop gypsum board on metal studs Durok 18 " (460 mm) floor protection 84" (2135 mm) min. fiberglass MANDATORY: plywood, particle or gypsum boards fiberglass free space 17" min. (430 mm) gypsum board on metal studs Durok 18 " (460 mm) floor protection 84" (2135 mm) min. air barrier Free depth See table next page vapour barrier (sealed with the vapour barrier of the wall) air barrier Free depth See table next page vapour barrier (sealed with the vapour barrier of the wall) Don-Bar, 741 St-Vallier West, Quebec, QC G1N 1E2 - Tel: (418) Fax: (418) Web: don-bar@don-bar.com REV Copyright Les Foyers Don-Bar inc.

6 INSULATED EXTERIOR CHASING Minimum dimensions of the exterior chasing Free interior dimensions of the insulated exterior chasing DANGER OF FIRE Never fill (stuff) with the empty spaces around the insulated case and around the insert. Moreover, non-mineral (foams, cellulose, cotton, etc.) needs a clearance from the fireplace and the insulated case of 12" (300 mm). Non combustible protection Non combustible cement board 1/2" (12 mm) (Durok) 84" (2135 mm) min. MANDATORY: metal studs Durok Durok 8" (200 mm) 58" (1470 mm) min. For the chasing depth: See the table below Gypsum board 1/2" (12 mm) 8" (203 mm) Non combustible floor protection: (Shall exceed the width of the door plus 8" (200 mm) on each side Exterior wall thickness (*) Minimum free depth Minimim free width Minimum free height 7" (180 mm) 27" (685 mm) 8" (200 mm) 28" (710 mm) Free depth of the exterior insulated chasing (varies according to the exterior wall thinkness) 9" (230 mm) 29" (740 mm) 10" (255 mm) 30" (760 mm) 58" (1470 mm) 84" (2135 mm) 11" (280 mm) 12" (305 mm) 31" 32" (790 mm) (810 mm) 13" (330 mm) 32" (810 mm) 14" (355 mm) 32" (810 mm) * The exterior wall inludes everything from the exterior finish to the interior finish. In case of doubt, please call Don-Bar. 25 LIMITED WARRANTY YEARS THE ZC SERIES MEET THE REQUIREMENTS OF: ULC S610 in Canada, UL 1482 in the USA EPA: Certified EPA Exempt Don-Bar, 741 St-Vallier West, Quebec, QC G1N 1E2 - Tel: (418) Fax: (418) Web: don-bar@don-bar.com REV Copyright Les Foyers Don-Bar inc.

7 ZERO CLEARANCE (ZC) Notes Don-Bar, 741 St-Vallier West, Quebec, QC G1N 1E2 - Tel: (418) Fax: (418) Web: don-bar@don-bar.com REV Copyright Les Foyers Don-Bar inc.

8 ZERO CLEARANCE (ZC) Notes 25 LIMITED WARRANTY YEARS THE ZC SERIES MEET THE REQUIREMENTS OF: ULC S610 in Canada, UL 1482 in the USA EPA: Certified EPA Exempt Don-Bar, 741 St-Vallier West, Quebec, QC G1N 1E2 - Tel: (418) Fax: (418) Web: don-bar@don-bar.com REV Copyright Les Foyers Don-Bar inc.