FACILITY COMPONENTS - ELEMENTARY SCHOOL

Size: px
Start display at page:

Download "FACILITY COMPONENTS - ELEMENTARY SCHOOL"

Transcription

1 SITE AREAS Parking and Access - Buses Two stalls fewer than minimum standard. Parking and Access - Service / Delivery Parking and Access - Staff Thirty-seven stalls fewer than minimum standard. Parking and Access - Visitors None. Student Drop Off - Pick Up None. Street Frontage Sidewalks On-Site Walkways Stairs and Ramps Exterior stairs do not have handrails and width is less than minimum standard. Hard Surface Play Areas ,000 SF less than minimum standard. Lawns Grass Play Area Athletic Surfacing Climbing Equipment Ground Surface Dumpster Area None. Dumpsters located in parking lot. Portable Classroom Infrastructure SITE IMPROVEMENTS Fences and Gates Backstop Fencing Pipe Rail Gates and Railings Retaining Walls Retaining wall at north playground is in poor condition. Bicycle Racks Bicycle rack size and location do not meet minimum standard. Dumpsters Exterior Benches Bench quantity does not meet minimum standards. Exterior Waste Receptacles Quantity does not meet minimum standards and no lids provided. Exterior Bleachers NA Flag Pole Climbing Equipment Playground Equipment Equipment quantities do not meet minimum standards. Playground Striping Quantity of basketball courts and box hockey do not meet minimum standard. Reader Board Site Sign None. Traffic Control Signs Existing signs in poor condition and additional signs needed. Pavement Markings Pavement markings are faded and worn. 11/21/2008 TP - Facility Component Assessment Page 1 of 7

2 LANDSCAPING Shrubs / Groundcover Trees Wetlands NA Irrigation System UTILITIES Water System Sanitary Sewer System Storm Drainage System Natural Gas Service Fuel Storage Tanks Electrical Service Telephone Service Cable Television Service Internet Connection Energy Usage - MBTUs / SF Building Energy consumption level does not meet minimum standards. Water Usage - Domestic Water / SF Bldg Domestic water usage level does not meet minimum standards. Water Usage - Irrig. Water / SF Landscape Irrigation water usage level does not meet minimum standards. STRUCTURE Foundation Floor Structure Wall Structure - Bearing Some walls do not meet minimum standard. Wall Structure - Non Bearing Roof Structure Some roof components do not meet minimum standards. BUILDING ENVELOPE Floors Exterior Wall Surface Exterior Wall Insulation Exterior Windows Single-pane glazing does not meet minimum standard. Exterior Doors Soffits Flashing Trim Gutters and Downspouts NA /21/2008 TP - Facility Component Assessment Page 2 of 7

3 Roof Membrane Roof membrane is at end of life expectancy. Roof Insulation Roof insulation does not meet minimum standard. Roof Accessories Skylights Skylight do not meet minimum standard for load capacity. Fall Arrest System No fall arrest system at playshed. Canopies NA INTERIORS Floors - Classrooms Floors - Corridors and Stairs Wood stairs at stage do not meet minimum standard. Floors - Gymnasium Floors - Kitchen Floors - Library Floors - Restrooms Floors - Support Spaces Walls - Classrooms Walls - Corridors and Stairs Walls - Gymnasium Walls - Kitchen Painted sheet rock walls do not meet minimum standard. Walls - Library Walls - Restrooms Walls - Support Spaces Asbestos-Containing Materials Interior Doors Door Hardware Automatic Door Opener Overhead Doors and Grilles Interior Windows Operable Walls No operable wall between stage and gym. Ceilings - Classrooms Ceilings - Corridors Height of corridor ceiling do not meet minimum standard and exposed piping present in some corridors. Ceilings - Gymnasium Ceiling height and material does not meet minimum standard. Ceilings - Kitchen Ceilings - Library ' ceiling height at north end of library does not meet minimum standard. Ceilings - Restrooms /21/2008 TP - Facility Component Assessment Page 3 of 7

4 Ceilings - Support Spaces EQUIPMENT AND SPECIALTIES Marker Boards Marker board quantity does not meet minimum standard in classrooms. Tackboards Interior Signage Toilet Partitions Toilet Accessories Lockers None. Residential Appliances Projection Screens Projection screens in library and gymnasium do not meet minimum standards. Stage Curtains Window Covering Window covering quality does not meet minimum standard and window covering missing in some areas. Cabinets - Classrooms Cabinets - Offices Cabinets - Storage Cabinets - Support Spaces Display Cases No built-in display case at front entry. Portable display case being used. Equipment - Art Equipment - Classrooms Eleven laser printers past life expectancy. Equipment - Food Service Cook top, combi-oven, mixer, hot food wells, and 3-compartment sink not provided. Walk-in cooler size does not meet minimum standard. Steam kettle and dishwasher need replacement. Equipment - Gymnasium Quantity of basketball backboards does not meet minimum standard. Equipment - Library Equipment - Offices / Workrooms Fax machine exceeds useful life and an additional photocopy machine needed. Equipment - Support Spaces Furniture - Classrooms Classroom furniture is old and in some cases does not meet minimum standard. Furniture - Library Library furniture is old. Some chairs and tables do not meet minimum standard. Furniture - Offices / Workrooms Office desks are old and worn. Furniture - Support Spaces Furniture is old and in some case does not meet minimum standards. Artwork NA Elevator NA Vending Machines Wheelchair Lift NA MECHANICAL 11/21/2008 TP - Facility Component Assessment Page 4 of 7

5 Fire Suppression System No fire sprinkler system. Plumbing Insulation Domestic Water Equipment Domestic Water Quality Some plumbing fixtures do not meet water quality standards. Soil and Waste Plumbing Fixtures Existing plumbing fixtures are in poor condition and require frequent maintenance. Natural Gas Piping HVAC Duct Insulation HVAC Pipe Insulation Hydronic Piping Hydronic Pumps Refrigerant Piping HVAC Ductwork HVAC Fans Heating / Ventilation System - Clrms Heating / Ventilation System - Gym Heating / Ventilation System - Library Heating / Ventilation System - Offices Heating / Ventilation System - Wkrm Heating / Vent. System - Support Spaces Air Terminal Units Ventilation Hoods No kiln hood. Boilers Boilers are beyond life expectancy. Furnaces NA Heat Exchangers NA Refrig. Compressors and Condensers Water Chillers NA Exhaust Fans Heat Pumps NA Fan Coil Units Unit Ventilators Unit Heaters Automatic Controls ELECTRICAL 11/21/2008 TP - Facility Component Assessment Page 5 of 7

6 Transformers Switchgear Panelboards Power Distribution Power Conditioning Wiring Devices Electrical Outlets - Classrooms Electrical Outlets - Library Quantity of electrical outlets in computer lab does not meet minimum standard. Electrical Outlets - Offices / Wkrms Quantity and location of electrical receptacles do not meet minimum standards. Electrical Outlets - Support Spaces Electrical Outlets - Emergency Power Circuit Protection Devices Packaged Generator Battery Equipment Lighting - Exterior - Bus Loading Lighting level does not meet minimum standard. Lighting - Exterior - Main Entry Lighting level does not meet minimum standard. Lighting - Exterior - Parking Lighting level does not meet minimum standard. Lighting - Exterior - Pathways Lighting level does not meet minimum standard. Lighting - Exterior - Playground NA Lighting - Exterior - Playshed NA Lighting - Exterior - Service / Delivery Lighting level does not meet minimum standard. Lighting - Classrooms Lighting level does not meet minimum standard. Lighting - Corridors Lighting level does not meet minimum standard. Lighting - Emergency Lighting - Gymnasium Lighting - Kitchen Lighting level does not meet minimum standard. Lighting - Library Lighting level does not meet minimum standard. Lighting - Restrooms Lighting level does not meet minimum standard. Lighting - Support Spaces Lighting level does not meet minimum standard. Lighting - Stage Automatic Lighting Control Exit Signs Data Communications Cabling Data Communications Equipment Equipment other than UPS does not meet minimum standards. 11/21/2008 TP - Facility Component Assessment Page 6 of 7

7 Data Comm. Outlets - Classrooms Data Comm. Outlets - Library Quantity of data outlets for computer lab does not meet minimum standard. Data Comm. Outlets - Office / Wkrms Data Comm. Outlets - Support Spaces Quantity of data outlets does not meet minimum standard. Wireless Data Communications Telephone / Intercom / Clock System Telephone Handsets Sound System Television System Audio - Video System Intrusion Detection Video Surveillance Fire Detection and Alarm TOTALS /21/2008 TP - Facility Component Assessment Page 7 of 7