1 AN ISO 9001 & COMPANY TENDER DOCUMENT TENDER No: WRO/CON/757/0188 FOR RCC Structural Works for Construction of Infectious Block Building at Kendrapara, Odisha state VOLUME III PRICE BID/BILL OF QUANTITIES

2 NIT No. WRO/CON/757/0188 ENGINEERING PROJECTS (INDIA) LTD. (A GOVERNMENT OF INDIA ENTERPRISE) QUOTING SHEET FOR BIDDERS NAME OF WORK RCC STRUCTURAL WORKS FOR CONSTRUCTION OF INFECTIOUS BLOCK BUILDING AT KENDRAPARA, ODISHA Summary SI. No. DESCRIPTION IN FIGURES TOTAL AMOUNT (Rs.) IN WORDS 1 CIVIL WORKS Grand Total Note: 1. Rates to be quoted in this tender shall be inclusive of all taxes and duties including GST. 2. The bidder has to show GST /Tax considered separately for reference. 1 Sign and Stamp of Bidder

3 ABSTRACT OF COST FOR RCC STRUCTURAL WORK FOR CONSTRUCTION OF INFECTIOUS BLOCK BUILDING AT KENDRAPARA PRICE BID Sl no Description Qty Unit RATE IN Rs. 1 Providing and laying in position machine batched and machine mixed design mix M30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineerincharge. (Note : Cement content considered in this item 390 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately). Due to space constraint for movement, mini mobile concrete mix batching plant can be considered. All works above plinth level upto floor V level Cum Rs.

4 2 Providing and laying in position machine batched and machine mixed design mix M30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineerincharge. (Note : Cement content considered in this item 390 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately). Due to space constraint for movement, mini mobile concrete mix batching plant can be considered. All works Above floor level V for each four floors or part thereof for M30 Grade cement concrete Cum Rs. 3 4 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. (Excluding Supply of Steel) ThermoMechanically Treated bars of grade Fe500 D or more. Centering and shuttering including strutting, propping etc. and removal of form for : kg Rs.

5 Suspended floors, roofs, landings, balconies and access platform sqm Rs. 5 Edges of slabs and breaks in floors and walls Under 20 cm wide Rmt Rs. 6 Weather shade, Chajjas, corbels etc., including edges 7 8 Lintels, beams, plinth beams, girders, bressumers and cantilevers Centering and shuttering including strutting, propping etc. and removal of form for : Sqm Rs sqm Rs. Columns, Pillars, Piers, Abutments, Posts and Struts sqm Rs. 9 Small lintels not exceeding 1.5 m clear span, moulding as incornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like sqm Rs. 10 Vertical and horizontal fins individually or forming box louvers band, facias and eaves boards

6 Sqm Rs. 11 Stairs, (excluding landings) except spiralstaircases sqm Rs. 12 Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc sqm Rs. 13 Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth sqm Rs.

7 14 Providing and fixing polystyrene backer rod in the expansion joint leaving required depth from the top to fill the sealant. The backer rod shall be installed in such a way that, the depth shall be equal to the width, if the width of the joint is lesser equal to 10mm, and for width of the joint above 10mm, depth shall be maintained half of its width.apply a coat of epoxy as a moisture barrier and install polysulfied sealant in the expansion joints.allow it to dry it completely.apply a belting of FASCRSEAL(Make Panache Greentech) immediately after diluted version of Hi seal slurry(make Panache Green) primer coat.apply the first coat over the primed surface. Install the sealing tape on wet surface of Water guard ensuring the sealing tape is completely embedded in the coat of water guard and allowed to dry (4 hours), apply the second coat of Water guard in opposite direction to the first coat and allow it to dry completely.protection plaster is recommended at additional cost RMT Rs. 15 Providing and fixing sheet covering over expansion joints with iron screws as per design. Aluminium fluted strips 3.15 mm thick. 150 mm wide RMT Rs.

8 16 75mm overall thickness partition with 12.5 mm thick double skin tapered edged plain Gypsum board conforming to IS: 2095: part I Sqm Rs. Electrical Conduits 17 Supply & Installation of 25mm HMS PVC conduits (Precision or equivalent make) for concealing in walls/slab All Floors RMT Rs. TOTAL IN FIG Rs. TOTAL IN WORDS