1 SECTION DOOR HARDWARE PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of DIVISION 0 - BIDDING AND CONTRACT REQUIREMENTS and other DIVISION 1 Specification Sections, apply to this section. 1.2 DESCRIPTION OF WORK A. Work Included: Provide labor, materials and equipment necessary to complete the work of this Section, including but not limited to the following: 1. Commercial door hardware for existing and proposed steel doors and frames. B. Related Sections: 1. Section STEEL DOORS AND FRAMES 1.3 REFERENCES A. The following is a list of standards which may be referenced in this section: 1.4 SUBMITTALS A. American National Standards Institute (ANSI): A117.1, Buildings and Facilities- Providing Accessibility and Usability for Physically Handicapped People. B. Builders Hardware Manufacturer s Association (BHMA): a. A156.1, Butts and Hinges. b. A156.2, Bored and Preassembled Locks and Latches. c. A156.3, Exit Devices. d. A156.4, Door Controls - Closers. e. A156.13, Mortise Locks and Latches, Series f. A156.16, Auxiliary Hardware. g. A156.18, Materials and Finishes. C. Door Hardware Institute (DHI): A115.1, Preparation of Mortise Locks in 1-3/8-Inch and 1-3/4-Inch Standard Steel Doors and Frames. D. Underwriters Laboratories, Inc. (UL): Fire Protection Equipment List. A. Action Submittals: A. Shop Drawings: a. Product Data: Manufacturer s literature for each item of finish hardware required herein, clearly marked. b. Finish Hardware Schedule: Furnish complete and detailed schedule, show product items, numbers, and finishes for hardware for each separate opening. c. Special Tools: Provide listing and description of usage

2 B. Samples: As required for color selection. B. Informational Submittals: A. Operation and Maintenance Data. B. Manufacturer s Field Service Report. C. Certification of Hardware Consultant. D. Manufacturer s Certificate of Proper Installation. 1.5 QUALITY ASSURANCE A. Qualifications of Supplier: Recognized supplier of architectural finish hardware, with warehousing facilities, who has been furnishing hardware in vicinity of Project for not less than 5 years, and who is, or who employs, architectural hardware consultant. B. Qualifications of Architectural Hardware Consultant (AHC): Certified by Door and Hardware Institute. 1.6 DELIVERY, STORAGE, AND HANDLING A. Before delivery, clearly identify and tag each item of hardware with respect to specified description and location of installation. B. Provide secure storage for finish hardware until installation is made. 1.7 EXTRA MATERIALS A. Special Tools: Two sets for installation and maintenance of hardware. PART 2 - PRODUCTS 2.1 MATERIALS A. Finishes: BHMA A B. All doors shall be openable from inside by simple turn of handle or knob or push of panic bar without use of a key or any special knowledge or effort. 2.2 HARDWARE SCHEDULE A. Provide hardware as listed below and scheduled for each door. Hardware items listed below are scheduled as products from specific manufacturers. The naming of a specific manufacturer's products is done solely to establish hardware item characteristics and quantities; equal hardware products by other manufacturers will be accepted. B. For new doors, Contractor shall provide all hinges and hardware necessary to attach the new door to the frame

3 C. Maher Wellhouse 1 (single door) Remove wood door and wood frame and furnish and install the following: Item # Description Hollow Metal Frame 1 see Section Insulated Metal Door 1 see Section Hinges 3 4 1/2 x 4 1/2 STD BB NRP 630 D. Maher Water Treatment Plant (double door) Replace existing Surface Vertical Rod exit devices and trim, and furnish and install the following: Item # Description Exit Device EO-48"-626 (SVR Panic Bar) x 996L-BE-626-LHR (lever blank escutcheon) Von Duprin Exit Device EO-48"-626 (SVR Panic Bar) x E996L-R/V-626-RHR (electrified lever trim) Von Duprin Cylinder Schlage Power Transfer 1 K-DLA-24" Keedex Door Closer HEDA LCN Alum TB/MS E. Mary Dunn Wellhouse 3 (single door) Remove existing lock hardware, cover lock hole, and furnish and install the following: Item # Description Cylindrical Lever 1 ND96PD-RHO-626 Schlage (Storeroom Lever) Electric Strike w/ J-630 Faceplate HES Hole Cover 1 BF-161PC Don Jo F. Mary Dunn Water Treatment Plant (double door) Remove existing Surface Vertical Rod device and trim, and furnish and install the following:

4 Item # Description Exit Device EO-36"-626 (SVR Panic Bar) x E996L-626-RHR (electrified lever trim) Cylinder Schlage Power Transfer 1 K-DLA-24" Keedex G. Mary Dunn Wellhouse 2 (single door) Remove hollow metal door, and furnish and install the following: Item # Description Insulated Metal Door 1 see Section H. Airport Wellhouse (single door) Remove existing lock hardware, and furnish and install the following: Item # Description I. Mary Dunn Wellhouse 4 Remove hollow metal door and frame, and furnish and install the following: Item # Description Hollow metal frame 1 see Section Insulated metal door 1 see Section Hinges 4 4 1/2 x 4 1/2 STD BB NRP 630 J. Hyannisport Water Treatment Plant (double door) Remove existing Surface Vertical Rod device and trim, and furnish and install the following: Item # Description Exit Device EO-36"-626 (SVR device) x E996L-626-RHR (electrified lever trim) Cylinder Schlage Power Transfer: 1 K-DLA-24" Keedex

5 K. Simmons Pond Well House (single door) Remove hollow metal door, and furnish and install the following: Item # Description Insulated metal door 1 See Section Electric Strike: w/ KD-630 Faceplate HES Door Closer: HEDA LCN Alum TB/MS Strike Guard: 1 ILP212-SL Don Jo L. Straightway Water Treatment Plant (single door) Remove existing lock hardware, and furnish and install the following: Item # Description M. Tank Site Building (single door) Furnish and install the following for a hollow metal door and frame provided by others: Item # Description Mortise Lock 1 L9080P-06A-626 Schlage 2.3 FASTENERS A. Stainless steel. 2.4 BUTT HINGES A. BHMA A B. Quantity per Door Leaf (Minimum): Door Height Up to 5'-0" 5'-1" to 7'-7" 7'-8" to 10'-0" 10'-1" to 12'-6" Hinges 1 pair 1-1/2 pair 2 pairs 2-1/2 pairs

6 C. Hinge Height (Minimum): Door Width Hinge Height Up to 3'-0" 4-1/2 3'-1" to 4'-0" 5 Over 4'-0" 6 D. Width: Minimum for clearance of trim and 180-degree swing. E. Provide non-removable pins at exterior hinges and where noted. F. Joint Tolerance: inch maximum, gauged in CLOSED position. 2.5 KEYING A. Lock Cylinders: Operate by master key system that allows for future expansion. B. Keylocks: Key new locks into existing master key system. As directed by Owner. C. Keys: Two per lock; tag with schedule information. D. Master Keys: Four. E. Furnish lock manufacturer s removable core maximum security keying system. 2.6 CONSTRUCTION KEY SYSTEM A. Removable construction core system for locks. B. See Article Manufacturer s Services under Part 3, Execution. 2.7 BOLTS A. BHMA A B. Finish: Satin stainless steel No KICKPLATES A. Solid metal, not plated. Bevel four edges. B. Width of door leaf less 1-1/2 inches at single leaf and less 1 inch at pairs. C. Finish: Satin stainless steel No D. Types and Manufacturers: Builders Brass Works, Baldwin, or Cipco as follows: A. K1 10 inches high by 0.05 inch thick

7 2.9 THRESHOLDS A. Thresholds: One-piece full width of opening; extend beyond jamb where indicated. B. Provide with stainless steel machine screws in threaded expansion anchors at concrete. C. Finish: Mill finish aluminum, unless indicated otherwise MISCELLANEOUS ITEMS A. Hardware for Fire Doors: Underwriters Laboratories Inc., Fire Protection Equipment List. PART 3 - EXECUTION 3.1 INSTALLATION A. In accordance with manufacturer s written instructions. B. Make Work neat and secure, develop full strength of components, and provide proper function. C. Prevent marring, scratching, or otherwise damaging adjacent finishes during hardware installation. D. Latchbolts: A. Install to engage in strikes automatically, whether activated by closers or manually. B. In no case shall additional manual pressure be required to engage latchbolt in strike. E. Stops and Holders: Set to allow doors to open as far as possible. F. Wall Mounted Hardware: Install over solid structural backing or solid blocking in hollow walls. G. Thresholds: A. Cope ends neatly to profile of jamb. B. Set in sealant and seal ends to jambs. H. Hardware: Adjust for easy, noise-free operation. I. Replace damaged hardware items. 3.2 MOUNTING DIMENSIONS A. Standard Door Hardware Locations: As recommended and published by Door and Hardware Institute, except as noted or detailed otherwise

8 3.3 MANUFACTURER S SERVICES A. Deliver permanent lock cores to Site. B. Remove temporary construction cores and insert permanent cores. C. Inspect each lock set to ensure permanent cores are operating satisfactorily. D. Deliver to Owner change and control keys for permanent system. E. Return temporary construction cores to manufacturer. F. Furnish manufacturer s representative for the following services at Site or classroom as designated by Owner, for minimum person-days listed below, travel time excluded: 3.4 PROTECTION A. 1/2 person-day for installation assistance, inspection, and Manufacturer s Certificate of Proper Installation. B. 1/2 person-day for functional and performance testing. A. Cover and protect exposed surfaces of hardware during installation and until Substantial Completion. B. Fit, dismantle, and reinstall finish hardware as required for finish painting work. C. Protect and prevent staining of hardware during construction in accordance with manufacturer s recommendations. D. Remove protective measures and permanent lock cylinders installed prior to final cleaning. END OF SECTION