2 Al Azizya Chemicals Factory is a Qatar based construction chemicals manufacturing company. We manufacture construction chemicals for all phases of construction from foundations to finishes under the International Brand name TurkQua. Our company Manufactures diverse range of products as to satisfy our valued clients expectations. Our products are suitable for newly build and projects in both commercial and residential sectors. TurkQua offers high-tech ecological products leading in the field of modern construction for waterproofing, acoustic and thermal insulation while respecting the nature. A new range of solutions for pre-mixed and prefabricated products to meet your needs for sealing, bonding, coating, reinforcement, construction and reconstruction, waterproofing, rehabilitation, restoration and thermo-acoustic insulation. Our products meet European standards and are designed by highly qualified engineers specialized in the field of building and who also thought of your imperative needs in terms of restoration in your different stages of application by guaranteeing you a perfect quality reducing the costs of implementation with great longevity in time. TurkQua products will give you complete satisfaction for your indoor and outdoor work with an exceptional quality. facebook/turkqua

3

4 Universal Primer Excellent multipurpose primer for all waterproofing and insulation applications Universal Primer Universal Primer is one part pre-coat formulated with special copolymer for good adhesion on multipurpose substrates. Suitable for absorbent and non-absorbent substrates before applying all Turkqua ML Waterproofing and Turkqua Plaster products. Good substrate preparation improves the Universal Primer performances: For new or unpainted interior and exterior masonry surfaces : Remove all imperfections and sand down for an even surface Remove dust, contaminants or foreign matter with damp cloth Allow surface to dry For previously painted interior and exterior masonry surfaces : Remove any loose, peeling or flaking paint using scrapper or water jet wash whichever is suitable Repair any imperfections. Fill cracks with suitable waterresistant putty or filler and sand down to an even surface Remove dust, contaminants or foreign matter with damp cloth Remove oil or grease by solvent cleaning or mild detergent. Allow surface to dry Ensure that the previously painted surface is sound g) If surface has a high gloss or semi-gloss finish, sand to remove the high gloss to enable the new paint to adhere Mix Universal Primer smoothly before use and apply it with a brush, roller or airless. Used as a multi-substrate sealer for both interior and exterior surfaces such as masonry walls, ceilings, wood, metal and plastic. Application surfaces include: Concrete and fiber board, Wooden doors, windows, furniture,ferrous metal such as fences, Piping and metal sheets, Plastic such as TPO and PVC Alkaline and efflorescence resistance Non-toxic, does not contain lead, chrome and other heavy metals Quick drying time with excellent adhesion Good tannin stain resistance Good coverage and hiding power Packaging : 19 ltr buckets Consumption Aprox Ltr / sqm / layer for non absorbent substrates Aprox. 0.5 Ltr / sqm / layer for absorbent substrates 4

5 JointECH High performance acrylic based joint filler Jointech Joint Etanche is based on acrylic and polymer features high filling and integration material. It has a very good resistance against UV, sun and weather conditions and it is elastic mastic. It s a single component and can be painted. It has long life and it is not flammable, it offers a good adhesion on any kind of surfaces that are absorbent, dry or slightly moist. Concrete must be fully cured (28 days). Following ACI 302 recommendation, apply joint fillers as late as possible after construction (ideally days to minimize additional slab shrinkage). Joint surfaces must be sound, dry, clean, free of dirt, moisture, loose particles, oil, grease, asphalt, tar, paint, wax, rust, waterproofing and curing or parting compounds, membranes, and other foreign matter. Clean concrete where necessary by grinding, sandblasting or wire brushing. Expose a sound surface free of contamination and laitance. Joint Etanche is ready to use product so shake smoothly the packaging before use. Install Joint Etanche at full joint depth to allow for proper load transfer. Do not use sand or backing materials to reduce volume. Clean, dry silica sand may be used to seal cracks in the base of the joint if approved by the specifier. Dilatation and extension joint fillers Drainer sides of chimney Extension filler and joint fillers Sides of roof covering, aluminum, glass, plastic woodwork Joint points of coverings such as stone, ceramic, marble and plinths etc Filling or repairing works of the cracks or the holes Joint integration points of prefabricated conduits and fronts. Packaging : 5kg and 20kg plastic buckets Consumption Approx. 1 kg / m2 / 1mm thickeness 5

6 ML UV Excellent elastomeric based waterproofing material ML UV ML UV is a versatile elastomeric paint with excellent adhesion to screed, concrete, fiber cement and cement tiles. Hard dry within 4 hours enabling two coats to be applied in the same day. Easy application with either brush or roller. No problems with clean up. Brushes and rollers can be washed with tap water. Its native white color is resistant to rain and alkaline salts found in cement tiles. However, it is applied over surfaces exposed to water and humidity, particularly suited to application on positive pressure side. It must be over coated with tiles, micro porous paints or coatings oncrete must be fully cured (28 days). Following ACI 302 recommendation, apply ML UV as late as possible after construction (ideally days to minimize additional slab shrinkage). Surfaces must be sound, dry, clean, free of dirt, moisture, loose particles, oil, grease, asphalt, tar, paint, wax, rust, waterproofing and curing or parting compounds, membranes, and other foreign matter. Clean concrete surfaces where necessary by grinding, sandblasting or wire brushing. Expose a sound surface free of contamination and laitance. ML UV is ready to use product so mix 1 minutes with mixer before use. Before application no need to add water or any other products. Cracks on concrete or screed must fix with Joint Etanche. Before first layer it must apply Universal Primer or AquaEtanche. Application of ML UV is with brush or roll with minimum 2 layers. First layer should be in one direction to all surface. After 24 hours second layer should be applicate opposite direction. Install ML UV at full surface to allow for proper load transfer. Do not use sand or backing materials to reduce volume. Clean, dry silica sand may be used to seal cracks in the base of the joint if approved by the specifier. Particularly suitable for rapid waterproofing on damp and wet surfaces before tiling No priming for tiling All types of substrates such as roof tiles and galvanized iron roofs. Other applications include side cladding galvanized iron elements, gutters and downpipes, fiber cement garden pots. Ready to use, elastomeric dispersion based waterproofing material Suitable on existing ceramic tiles, cement and gypsum based surfaces Paintable. Packaging: 20 kg plastic bucket Consumption: Approx. 1 kg / m2 / 1 mm layer 1 Surface Treatment: Joint Etanche 2. Primer: Universal Primer, AquaEtanche 3. Waterproofing: ML UV, ML POLYMER 6

7 ML POLYMER Special waterproofing polymer ML POLYMER ML POLYMER is one part, solvent-free, pure acrylic-based special waterproofing polymer produced by the latest technology. It has up to 600% elongation property. It is ready to use UV resistant, bright, hard elastic and walk able. It is not affected by pedestrian and vehicle traffic or chemicals Concrete must be fully cured (28 days). Following ACI 302 recommendation, apply ML POLYMER as late as possible after construction (ideally days to minimize additional slab shrinkage). Surfaces must be sound, dry, clean, free of dirt, moisture, loose particles, oil, grease, asphalt, tar, paint, wax, rust, waterproofing and curing or parting compounds, membranes, and other foreign matter. Clean concrete or galvanized iron surfaces where necessary by grinding, sandblasting or wire brushing. Expose a sound surface free of contamination and laitance.ml POLYMER is ready to use product so mix 1 minutes with mixer before use. Before application no need to add water or any other products. Cracks on concrete or screed must fix with Joint Etanche. Before first layer it must apply Universal Primer or AquaEtanche. Application of ML POLYMER is with brush, airless or roll with minimum 2 layers. First layer should be in one direction to all surface. After 24 hours second layer should be applicate opposite direction. Application ML POLYMER at full surface to allow for proper load transfer. Do not use sand or backing materials to reduce volume. Clean, dry silica sand may be used to seal cracks in the base of the joint if approved by the specifier. Can be used for insulations of roof terrace and balconies, insulations of wet room and foundation walls, floors of factory and depot, park and walk ways, water lakes, terraces and roofs, on metal roofs, woods, on bituminous problematic insulations and all kinds of asphalt and concrete surfaces Easily applied as a waterproofing agent for roofs and balconies, canals, chimney surroundings, gutters and strainers in wide area and detailed, flat or inclined roofs To improve its performance, use fiber glass or geotextile as reinforcement (density up to 60gr/sq.) Repair of concretes and protection of structures exposed to marine environment and salts Packaging : 20 kg plastic buckets Consumption Approx kg for non-absorbent and 0.5 kg for absorbent surfaces / m2 1 Surface Treatment: Joint Etanche 2. Primer: Universal Primer, AquaEtanche 3. Waterproofing: ML UV, ML POLYMER 7

8 ML SDB Excellent under-tile water insulation coating ML SDB ML SDB is a one part, solvent-free, pure acrylic-based special waterproofing polymer produced by the latest technology for under ceramic waterproofing Concrete must be fully cured (28 days). Following ACI 302 recommendation, apply ML SDB as late as possible after construction (ideally days to minimize additional slab shrinkage). Surfaces must be sound, dry, clean, free of dirt, moisture, loose particles, oil, grease, asphalt, tar, paint, wax, rust, waterproofing and curing or parting compounds, membranes, and other foreign matter. Clean concrete where necessary by grinding, sandblasting or wire brushing. Expose a sound surface free of contamination and laitance. ML SDB is ready to use product so mix 1 minutes with mixer before use. Before application no need to add water or any other products. Cracks on concrete or screed must fix with Joint Etanche. Before first layer it must apply Universal Primer or AquaEtanche. Application of ML SDB is with brush or roll with minimum 2 layers. First layer should be in one direction to all surface. After 24 hours second layer should be applicate opposite direction. Install ML SDB at full surface to allow for proper load transfer. Do not use sand or backing materials to reduce volume. Clean, dry silica sand may be used to seal cracks in the base of the joint if approved by the specifier Positive side insulations of the wall and grounds ainsulations on the concrete, plaster and alum applications Balcony, terrace, swimming pools, bathrooms, WC Pre-cast and pre-fabricated elements, roofs Packaging: 20 kg plastic bucket Consumption: Approx. 1 kg / m2 for each layer 1 Surface Treatment: Joint Etanche 2. Primer Application: Universal Primer, AquaEtanche 3. Waterproofing: ML Hybrid, ML SPER 2K, ML SDB 8

9 ML B-80 Excellent bitumen-acrylic based waterproofing material ML B-80 ML B-80 is a ready to use, bitumen-acrylic emulsion based waterproofing material. It is applied over surfaces exposed to sun, water and humidity, particularly suited to application on roofs. Optionally, it can be over coated with tiles Concrete must be fully cured (28 days). Following ACI 302 recommendation, apply ML B-80 as late as possible after construction (ideally days to minimize additional slab shrinkage). Surfaces must be sound, dry, clean, free of dirt, moisture, loose particles, oil, grease, asphalt, tar, paint, wax, rust, waterproofing and curing or parting compounds, membranes, and other foreign matter. Clean concrete or galvanized iron surfaces where necessary by grinding, sandblasting or wire brushing. Expose a sound surface free of contamination and laitance.ml B-80 is ready to use product so mix 1 minutes with mixer before use. Before application no need to add water or any other products. Cracks on concrete or screed must fix with Joint Etanche.Before first layer it must apply primer. Add %50 water to ML B-80 to make primer. Application of ML UV is with brush or roll with minimum 2 layers. First layer should be in one direction to all surface. After 24 hours second layer should be applicate opposite direction. Install ML B-80 at full surface to allow for proper load transfer. Do not use sand or backing materials to reduce volume. Clean, dry silica sand may be used to seal cracks in the base of the joint if approved by the specifier Fusion of acrylic and bitumen high performances Suitable for roofs and all kinds of exposed surfaces No priming needed To improve its performance, use fiber glass or geotextile as reinforcement (density up to 60gr/sqm) Ready to use, extremely elastic Pack aging:18 lt plastic bucket Consumption: Approx. 1kg /M2 /1 mm layer 1 1. Old Ceramic 2. Surface Treatment: PR-40, Mix Premier 3. Waterproofing: ML Hybrid, ML SPER 2K, ML SDB 4. Fixing Ceramic with adhesive: Seramika Granite&Pool, SuperFlex, Silicon Joint Filler 9

10 ML Hybrid Excellent semi-elastic water insulation coating ML HYBRID ML Hybrid is cement and acrylic-based, semi-elastic, 2 components water insulation material. Components must be mixed before application. Resistant to positive water pressure Concrete: Turkqua PWS-8, SPL-11, HPL-15, Latex 2. Screed: Chape Auto 3. Waterproofing: ML Hybrid, ML SPER 2K, ML SDB 4. Fixing Ceramic with adhesive: Seramika Granite&Pool, SuperFlex, Silicon Joint Filler 4 Concrete must be fully cured (28 days). Following ACI 302 recommendation, apply ML Hybrid as late as possible after construction (ideally days to minimize additional slab shrinkage). Surfaces must be sound, dry, clean, free of dirt, moisture, loose particles, oil, grease, asphalt, tar, paint, wax, rust, waterproofing and curing or parting compounds, membranes, and other foreign matter. Clean concrete surfaces where necessary by grinding, sandblasting or wire brushing. Expose a sound surface free of contamination and laitance. ML Hybrid is 2 component product, component A is cement based powder product and component B is acrylic based liquid product. Firstly put half quantity of B in clean bucket and add slowly component A while mixing than add rest of component B with 3-5lt water in bucket and continue to add component A slowly until mix all quantity. Application can need primer so AquaEtanche or Universal Primer can use 100gr/m2 before application of ML Hybrid Product should be applicate in first coat in one direction before product dry it is possible to fix Geotextile if necessary. After 24 hours second coat should applicate all surface opposite direction than first coating.after 24 hours of second coating it is possible to apply ceramic adhesive and fix ceramic or tile on surface. Application to ML Hybrid at full surface to allow for proper load transfer. Do not use sand or backing materials to reduce volume. Clean, dry silica sand may be used to seal cracks in the base of the joint if approved by the specifier. Indoor and outdoor Horizontal and vertical applications Wet areas, such as bathroom, kitchen, balcony Water tanks, swimming pools (under the coverage) To improve its performance, use fiber glass or geotextile as reinforcement (density up to 60gr/m2) Groundwork isolation Isolation of deck roofs Retaining walls Packaging: Comp. A: 25 kg craft bags Comp. B: 6 kg plastic drums Consumption: Approx. 1kg /M2 for each layer 10

11 ML Super 2K Excellent super elastic water insulation coating ML SUPER 2K ML Super 2K is a cement and acrylic-based, super-elastic, double components water insulation material. Components must be mixed before application. Resistant to positive water pressure Concrete: Turkqua PWS-8, SPL-11, HPL-15, Latex 2. Primer: ML B80 +%50 Water, ML B80 2K +%50 Water 3. Waterproofing: ML B-80, ML B-80 2K 3 Concrete must be fully cured (28 days). Following ACI 302 recommendation, apply ML Super 2K as late as possible after construction (ideally days to minimize additional slab shrinkage). Surfaces must be sound, dry, clean, free of dirt, moisture, loose particles, oil, grease, asphalt, tar, paint, wax, rust, waterproofing and curing or parting compounds, membranes, and other foreign matter. Clean concrete surfaces where necessary by grinding, sandblasting or wire brushing. Expose a sound surface free of contamination and laitance. ML Hybrid is 2 component product, component A is cement based powder product and component B is acrylic based liquid product. Firstly put half quantity of B in clean bucket and add slowly component A while mixing than add rest of component B in bucket and continue to add component A slowly until mix all quantity. Application can need primer so AquaEtanche or Universal Primer can use 100gr/ m2 before application of ML Hybrid Product should be applicate in first coat in one direction before product dry it is possible to fix Geotextile if necessary. After 24 hours second coat should applicate all surface opposite direction than first coating. After 24 hours of second coating it is possible to apply ceramic adhesive and fix ceramic or tile on surface. Install ML Super 2K at full surface to allow for proper load transfer. Do not use sand or backing materials to reduce volume. Clean, dry silica sand may be used to seal cracks in the base of the joint if approved by the specifier Can be used indoor and outdoor for horizontal and vertical applications, water tanks, cisterns, swimming pools (under the coverage), groundwork isolation, retaining walls and basement isolation, isolation of deck roofs, irrigation channels, manholes, concrete pipes, wet areas such as bathroom, kitchen, balcony, facilities such as thermal springs, Turkish baths, isolation of concrete flower receptacle, bonding ceramics, granite and covering materials To improve its performance, use fiber glass or geotextile as reinforcement (density up to 60gr/m2) Repair of concrete and protection of structures exposed to marine environment and salts Packaging : Comp. A: 25 kg craft bags Comp. B: 12 kg plastic drums Consumption Approx. 1 kg / m2 for each layer 11

12 Tel : enquiries@alazizyachemicals.com P.O.Box : 21898, Street 1, New Industrial Area, Doha - Qatar