Modern-Day Timber Architects and Engineers: Design Skills for Mass Timber Buildings

Size: px
Start display at page:

Download "Modern-Day Timber Architects and Engineers: Design Skills for Mass Timber Buildings"

Transcription

1 Please add relevant logo here Modern-Day Timber Architects and Engineers: Design Skills for Mass Timber Buildings Mass Timber Code Applications and Acoustics Ethan Martin, PE WoodWorks Photo: Alex Schreyer

2 The Wood Products Council is a Registered Provider with The American Institute of Architects Continuing Education Systems (AIA/CES), Provider #G516. Credit(s) earned on completion of this course will be reported to AIA CES for AIA members. Certificates of Completion for both AIA members and non-aia members are available upon request. This course is registered with AIA CES for continuing professional education. As such, it does not include content that may be deemed or construed to be an approval or endorsement by the AIA of any material of construction or any method or manner of handling, using, distributing, or dealing in any material or product. Questions related to specific materials, methods, and services will be addressed at the conclusion of this presentation.

3 Course Description Mass timber represents a rapidly advancing technology that can be utilized as an alternative to steel and concrete to frame a variety of mid- and high-rise building types. As it transitions from novelty to mainstream, many architects and engineers are finding they need a deeper understanding of the unique design considerations associated with this new construction type. Intended to provide practical knowledge that can be applied to projects right away, this workshop focuses on four key mass timber design topics: acoustics resources and tested assembles; fire resistance with an emphasis on cross-laminated timber, including char calculations and fireresistance ratings; building enclosure detailing and best practices; and structural performance including design processes for mass timber products in gravity force-resisting systems.

4 Learning Objectives 1. Review code-compliant applications of mass timber products such as cross-laminated timber (CLT) and gluelaminated timber under the 2015 International Building Code (IBC). 2. Consider how various aspects of CLT fire performance apply (or don't apply) to code-compliant low- and midrise vs. high-rise buildings. 3. Discuss building enclosure design principles for mass timber buildings. 4. Demonstrate structural design steps for members and connections in common mass timber framing systems.

5 Mass timber is a category of framing Mass timber What is it? styles often using small wood members formed into large panelized solid wood construction including CLT, NLT or glulam panels for floor, roof and wall framing

6 Building frame systems Post and Beam Light Frame Mass Timber

7 Photo Credit: lendlease Mass timber products Vertical framing Photo Credit: Josh Partee Glulam Beams & Columns Cross Laminated Timber (CLT) walls

8 Nail-Laminated Timber (NLT) Cross-Laminated Timber (CLT) Mass timber products horizontal framing Glue-Laminated Timber (GLT) Tongue & groove decking (T&G) Timber concrete composite Structural composite Lumber Image source: structurecraft

9 Mass timber products glulam Photo Credit: alex schreyer

10 Mass timber products glulam Glulam = a structural composite of lumber and adhesives Recognized in IBC using ANSI/AITC A and ASTM D 3737 Can be used for floor, roof purlins, beams, arches, columns

11 glulam specs: Typical Widths: 3-1/8, 3-1/2, 5-1/8, 5-1/2, 6-3/4, 8-3/4, 10-3/4, 12-1/4 Mass timber products glulam Typical Depths: Increments per # of lams from 6 to 60 + western species lams are typically 1-1/2 thick Southern pine lams are typically 1-3/8 thick Typical Species: Douglas-Fir, Southern Pine, Spruce Also available in cedar & others width depth Image: APA Glulam Product Guide

12 Mass timber products glulam Framing Grade Glulam appearance grades Industrial Grade Architectural Grade Images: American Laminators Premium Grade

13 Flexibility of spans and shapes Richmond Olympic Oval, Richmond, BC, Canada Design Team: Cannon Design Architecture, Fast + Epp, Glotman Simpson Photo Credit: Stephanie Tracey, Craig Carmichael, Jon Pesochin, KK Law Creative, Ziggy Welsch

14 Lemay america auto musuem Photo Credit: western wood structures 104 Span Glulam Arches Glulam 4 o.c

15 Buffalo Harbor Center Rink 1, Buffalo, NY Photo: Harborcenter.com

16 Long span glulams Photo: American wood council

17 Photo Credit: Josh Partee Radiator building Portland, or

18 Radiator building Portland, or Building info: Office building 5 stories 36,000 sf Completed 2015 Photo Credit: Josh Partee

19 Long term sustainability One north Portland, or Why a Timber Framed Office Building? Wood consumes and sequesters carbon. There s a lot of momentum for this. Timber framing is so much more sustainable. Ben Kaiser of PATH Architecture, Project Architect, Developer, and General Contractor Photo Credit: Josh Partee

20 Photo credit: structurecraft Nail Laminated Timber

21 Nail-laminated timber (nlt) = a structural panel of square-edged dimensional lumber laminations (usually 2x) set on edge and nailed wide face together Recognized in IBC (mechanically laminated decking) Nds provides distribution factors for concentrated loads Can be used for floor, roof decking. Occasionally used for shaft walls Mass timber products Nail-laminated timber (NLT) panels

22 Mass timber products Nail-laminated timber (NLT) panels Content includes: Architecture Fire Structure Enclosure Supply and Fabrication Construction and Installation Erection engineering

23 Photo credit: structurecraft Mass timber products Nail-laminated timber (NLT) panels Fluted panel options Vary lamination depths

24 Mass timber products Nail-laminated timber (NLT) panels pre-fabricated panels often pre-sheathed Photo Credit: structurecraft Once installed, add stitching strips, tape joint if applicable

25 Photo Credit: bullitt center Bullitt center Seattle, wa

26 Bullitt center Seattle, wa Building info: Office building 4 stories mass timber over 2 stories concrete 52,000 sf Net zero Living building challenge certified Type IV construction 250 yr design life Completed 2013 Photo Credit: miller hull partnership

27 Bullitt center Seattle, wa Photo Credit: John Stamets Nail-Laminated Timber Decks Provide: Maximized Spans, Reduced Number of Columns, More Open Space Flexibility, Minimized Structure Depth

28 Mass timber products Dowel-laminated timber (DLT) panels Photo credit: StructureCraft

29 Mass timber products Dowel-laminated timber (DLT) panels DLT: Similar to NLT Nails Connecting Lams replaced with hardwood dowels Common in Europe often referred to as Brettstapel Not currently recognized as prescriptively permitted material in IBC Timber Framers Guild resources on dowel design Photo credit: Guardian Structures

30 Mass timber products Glue-laminated timber (glt) panels Photo credit: Structure Fusion Photo credit: unalam

31 Mass timber products Glue-laminated timber (glt) panels Image source: manasc isaac architects/fast + epp Glulam decking: Similar to deep glulam beams laid on their side Same code references and manufacturing standards as glulam beams and columns Be careful of design stresses and layups used spec uniform layup (all lams same species & grade) Image source: structurecraft

32 Mass timber products Tongue and groove decking Tongue and groove decking: 2x, 3x or 4x solid or laminated wood decking laid flat with interlocking tongue and groove on narrow (side) face Recognized in IBC (lumber decking) 2x usually has a single t&g; 3x and 4x usually have a double t&g 6 and 8 are common widths Can be used for floor, roof decking Multi-ply laminated t&g Photo credit: josh partee

33 Mass timber products Tongue and groove decking T&g diaphragm design Can be used by itself as a diaphragm: sdpws table 4.2d Or add layer of wsp on top, treat as blocked diaphragm

34 Photo: joshua jay elliot framework Portland, or

35 framework Portland, or Photo: joshua jay elliot 4 stories of wood (office) over 1 story of concrete (retail & parking) 6,800 sf Completed 2015

36 Mass timber products Cross-laminated timber (clt)

37 What is clt? Solid wood panel 3 layers min. of solid sawn lams 90 deg. cross-lams Similar to plywood sheathing Mass timber products Cross-laminated timber (clt) Major Axis 4 1/8 to 19 1/2 10 X40 8 X64 Minor Axis

38 Common clt layups 3-ply 3-layer 5-ply 5-layer Mass timber products Cross-laminated timber (clt) 7-ply 5-layer 9-ply 7-layer 7-ply 7-layer 9-ply 9-layer

39 Mass timber products Cross-laminated timber (clt)

40 Mass timber products Cross-laminated timber (clt) Photo Credit: Sissi Slotover-Smutny Clt prefabrication Finished panels are planed, sanded, cut to size. Then openings are cut with precise CNC routers. Third party inspection at factory Custom engineered for material efficiency Custom designed for project Each panel numbered, delivered & installed in predetermined sequence

41 ALBINA YARD PORTLAND, OR 4 stories 16,000 sf Green Roof ARCHITECT: Lever Architecture IMAGE CREDIT: Lever Architecture

42 ARCHITECT: Lever Architecture IMAGE CREDIT: LEVER Architecture 20 x20 Grid, 12 Floor to Floor 3-ply CLT floor panels with electrical conduit poured into 1 light weigh gypsum topping Wood shearwall core with open front design for glazing wall ALBINA YARD PORTLAND, OR CLT panels for an entire floor installed in 3.5 hours

43 In 2015 IBC, CLT is now defined in Chapter 2 Definitions: Mass timber products Cross-laminated timber (clt) And is referenced in Chapter 23:

44 Mass timber products Cross-laminated timber (clt) CLT product standard ANSI / APA PRG 320 Standard for Performance Rated Cross-Laminated Timber

45 Mass timber design Construction types Q: of the 5 construction types, which ones can mass timber be used in? a: all 5!

46 Construction types IBC 602 IBC DEFINES 5 CONSTRUCTION TYPES: I, II, III, IV AND V A BUILDING MUST BE CLASSIFIED AS ONE OF THESE CONSTRUCTION TypeS I & II: ALL ELEMENTS REQUIRED TO BE NON-COMBUSTIBLE MATERIALS HOWEVER, THERE ARE EXCEPTIONS INLCUDING SEVERAL FOR MASS TIMBER

47 ALL WOOD FRAMED BUILDING OPTIONS: Construction types IBC 602 Type III Exterior walls non-combustible (may be FRTW) Interior elements any allowed by code, INCLUDING MASS TIMBER Type V All building elements are any allowed by code, INCLUDING MASS TIMBER Types III and V are subdivided to A (protected) and B (unprotected) Type IV (Heavy Timber) Exterior walls non-combustible (may be FRTW OR CLT) Interior elements qualify as Heavy Timber (min. sizes, no concealed spaces)

48 CONCEALED SPACES Type IV Construction requires that interior elements be without concealed spaces: Concealed spaces include dropped ceilings, attics, chases, others Concealed space restriction does not apply to any other construction type. If using mass timber elements in non type IV construction, concealed spaces are permitted but may be required to be sprinklered Ibc permits 1 hour fire resistance rated construction for partitions Construction types Ibc 602 Example of concealed space created by dropped ceiling

49 Noise Acoustics Sound Pollution Whatever you call it, it all comes down to one thing: Occupant Comfort

50 Acoustical Design Types of noise to control: Interior to interior Image credit: Eckert & Eckert Photography, GBD Architects

51 Acoustical Design Air-Borne Sound: Sound Transmission Class (STC) Measures how effectively an assembly isolates air-borne sound and reduces the level that passes from one side to the other Applies to walls and floor/ceiling assemblies

52 Acoustical Design Structure-borne sound: Impact Insulation Class (IIC) Evaluates how effectively an assembly blocks impact sound from passing through it Only applies to floor/ceiling assemblies

53 Acoustical Criteria IBC 1207 Code requirements only address residential occupancies: For unit to unit or unit to public or service areas: Min. STC of 50 (45 if field tested): Walls, Partitions, and Floor/Ceiling Assemblies Min. IIC of 50 (45 if field tested) for: Floor/Ceiling Assemblies

54 Acoustical Criteria

55 Room Acoustics What is Sound Absorption? All Materials absorb sound energy to some degree. Whenever sound waves strike a material, part of the acoustical energy in the wave is absorbed and/or transmitted, and the remainder is reflected. Arena Stage, Washington, DC Image Credit: Nic Lehoux, Bing Thom Architects

56 Room Acoustics Image Credit: NLT Design Guide NRC of exposed wood panels like NLT & DLT can be improved with inset absorbing materials Image Credit: StructureCraft

57 Acoustical Detailing Mass Timber Wall Acoustics - STC Photo Credit: Pam Wean, MSES Architects Image Credit: Lend Lease & Schaefer

58 Acoustical Detailing Sound Insulation of Bare CLT Floors and Walls Number of layers Thickness (in. ) Wall or Floor STC IIC Number of layers 3 3-3/4 to 4-1/2 Wall N.A /3 Floor /4 Floor Measured on field bare CLT wall and floor Thickness in. Assembly FSTC type FIIC 3 4-1/8 Wall 28 N.A /5 Floor N.A Credit: US CLT Handbook

59 Design Examples for >50 STC Walls Acoustical Detailing - STC 50: 1 and 3 = 4-1/2 in. CLT; 2=1-1/8 in. Mineral wool in the gap -STC 55: Adding 5/8 in. gypsum board directly to both sides - STC 60: with the gypsum boards and double the thickness of the gap and mineral wool - STC 58: 1 and 7 = 5/8 in. gypsum boards 3 and 5 = 2 in. by 3 in. wood studs at least 16 in. o.c. 2 and 6 = 2.5 in. mineral wool 4 = 4-1/2 in. CLT Credit: US CLT Handbook

60 Design Examples for >45 FSTC Walls Acoustical Detailing Top view of cross-section Wall detail FSTC 1& 5 = 5/8 Gypsum board 2& 4 = Resilient channels at 24 o.c layer CLT of 7-1/4 46 1& 7 = 5/8 Gypsum board 2& 6 = Resilient channels at 24 o.c 3& 5 = 3-layer CLT of = 1 air gap filled with mineral wool 47 Credit: US CLT Handbook

61 Design Examples for >45 FSTC Walls Acoustical Detailing Top view of cross-section Wall detail FSTC 1 = 3-layer CLT ~ 4-1/ = 1/2 air gap 3 = 2 by 3 wood studs at 16 o.c. 4 = 2-1/2 mineral wool 5 = 5/8 gypsum board 1 & 9 = 5/8 gypsum board 50 2 & 7 = 2 by 3 wood studs at 16 o.c. 4 & 6 = 1/2 air gap 5 = 3-layer CLT of 4-1/8 Credit: US CLT Handbook

62 Acoustical Detailing Mass Timber Floor Acoustics STC & IIC Image credit: John Stamets

63 Mass timber design Acoustics Main difference between light frame wood floors and mass timber floors is that mass timber floors are usually left exposed on ceiling side All acoustical products applied on top of assembly Image credit: Structurlam

64 Image credit: Maxxon Acoustical Detailing Lightweight concrete topping or other similar materials can provide improved acoustical performance, increased durability

65 Decoupled: Acoustical mat - typically installed between subfloor and topping or flooring. Can use multiple decoupling layers in sandwich assembly Acoustical Detailing Image credit: Pliteq

66 Acoustical Detailing Common mass timber floor assembly: Finish floor (if applicable) Underlayment (if finish floor) 1.5 to 3 thick concrete/gypcrete topping Acoustical mat WSP (if applicable) Mass timber floor panels Image credit: AcoustiTECH

67 Acoustical Detailing Options without concrete topping: Gypsum/cement board (Fermacell, Permabase, etc.) Proprietary products Image credit: AcoustiTECH

68 Image credit: Regupol Acoustical Detailing Options without concrete topping: Wood sleepers Honeycombs Sand fill Mineral wool insulation Image credit: US CLT Handbook

69 CLT Acoustics Resources: US CLT Handbook Acoustics Manufacturers Literature: Maxxon Pliteq AcoustiTECH Regupol Rothoblaas Industry tests FP Innovations, NRCAN Contact WoodWorks for information

70 Acoustical Detailing What about other mass timber floor panels? Image credit: Ema Peter

71 NLT Acoustics

72 GLT Acoustics Image credit: Regupol Image credit: Structure Fusion

73 T&G Deck Acoustics Image credit: Maxxon Image credit: Pliteq

74 Mass Timber Sealant Strips Acoustical Detailing Credit: Rothoblaas Structural Connection Isolation

75 Questions? This concludes The American Institute of Architects Continuing Education Systems Course Ethan Martin, PE WoodWorks Pacific Northwest Mobile: Web:

76 Copyright Materials This presentation is protected by US and International Copyright laws. Reproduction, distribution, display and use of the presentation without written permission of the speaker is prohibited. The Wood Products Council 2018