1 Drawing Description STO DRAWING REGISTER Drawing No. Drawing Register STM Introduction Series 000 StoTherm Masonry Insulation System - Introduction STM 003 Block Layout Series 100 StoTherm Masonry Insulation System - Isometric STM 100 StoTherm Masonry Insulation Panel Layout - Elevation STM 101 StoTherm Masonry Insulation Anchor Layout - Elevation STM 102 StoTherm Masonry Insulation Masonry Fixing STM 103 Foundation Series 200 StoTherm Masonry Insulation System Wall/Footing Junction STM 200 StoTherm Masonry Insulation System Below Ground Insulation STM 201 Walls Series 300 StoTherm Masonry Insulation System External Corner STM 300 StoTherm Masonry Insulation System Internal Corner STM 301 StoTherm Masonry Insulation System Control Joint Detail STM 302 StoTherm Masonry Insulation System Stair Waterproofing Detail STM 303 Wall Penetrations & Fittings Series 350 StoTherm Masonry Insulation System Pipe Penetration (up to 150mm Ø) Detail STM 350 StoTherm Masonry Insulation System Meterbox details STM 351 StoTherm Masonry Insulation System Light Fitting/Fixing Detail STM 352 StoTherm Masonry Insulation System Tap Fitting/Fixing Detail STM 353 StoTherm Masonry Insulation System Handrail Bracket/Fixing Detail STM 354 StoTherm Masonry Insulation System Downpipe Saddle Fixing STM 355 StoTherm Masonry Insulation System Fan Vent Detail STM 356 Joinery Series 400 StoTherm Masonry Insulation System Alu.Joinery - Head & Sill Detail STM 400 StoTherm Masonry Insulation System Alu.Joinery - Jamb Detail STM 401 StoTherm Masonry Insulation System Timber Joinery - Head & Sill Detail STM 402 StoTherm Masonry Insulation System Timber Joinery - Jamb Detail STM 403 StoTherm Masonry Insulation System Alu.Entry Door Head & Threshold Detail STM 404 StoTherm Masonry Insulation System Timber Entry Door Head & Threshold Detail STM 405 StoTherm Masonry Insulation System 20mm insulation to rebate - Head & Sill Detail STM 406 StoTherm Masonry Insulation System 20mm insulation to rebate - Jamb Detail STM 407 StoTherm Masonry Insulation System 40mm insulation to rebate - Head & Sill Detail STM 408 StoTherm Masonry Insulation System 40mm insulation to rebate - Jamb Detail STM 409 Parapets, Balustrades, Decks Series 500 StoTherm Masonry Insulation System Parapet/Metal Flashing Detail STM 500 StoTherm Masonry Insulation System Rendered Balustrade Detail STM 501 StoTherm Masonry Insulation System Parapet/Roof/Wall Detail STM 502 StoTherm Masonry Insulation System Insulated Roof / Deck to Walls STM 503 THESE DETAILS ARE ISSUED AS A GUIDE USING STANDARD BUILDING PRACTICES BASED ON THE NZBC. VARIOUS BUILDING COMPONENTS ARE DETAILED AND IT IS THE RESPONSIBILITY OF EACH TRADE INVOLVED TO ENSURE THAT THEIR PARTICULAR ELEMENTS ARE INSTALLED CORRECTLY. NOTE: REFER TO INDIVIDUAL MANUFACTURES FOR CURRENT DETAILS AND SPECIFICATIONS - SEE FOR CURRENT DETAILS. RBW DETAILS MUST BE ISSUED BY A; REGISTERED ARCHITECT, LICENSED DESIGNER OR CHARTERED ENGINEER PAGE 1 OF 2 INSULATION SYSTEM DRAWING REGISTER STM 001

2 Drawing Description STO DRAWING REGISTER Drawing No. Soffit Series 600 StoTherm Masonry Insulation System Flat Soffit STM 600 StoTherm Masonry Insulation System Raking Soffit STM 601 StoTherm Masonry Insulation System Raking Soffit (reversed) STM 602 StoTherm Masonry Insulation System Face Fixed Fascia STM 603 Roof Series 700 StoTherm Masonry Insulation System Barge with Overhang STM 700 StoTherm Masonry Insulation System Parallel Apron Flashing at Parapet STM 701 StoTherm Masonry Insulation System Eaves with Overhang STM 702 StoTherm Masonry Insulation System Eaves without Overhang STM 703 StoTherm Masonry Insulation System Parallel Apron Flashing STM 704 StoTherm Masonry Insulation System Transverse Apron Flashing STM 705 StoTherm Masonry Insulation System Parallel Roof/Hidden Gutter STM 706 StoTherm Masonry Insulation Face Fixed Fascia/Membrane Roof STM 707 Dissimilar Material Bevel-Back Weatherboard Series 800 StoTherm Masonry Insulation System Ext.Corner STM 800 StoTherm Masonry Insulation System Int.Corner STM 801 StoTherm Masonry Insulation System Horizontal Junction STM 802 Brick Series 810 series not issued Fibre Cement Sheet Series 820 series not issued Manufactured Stone - Schist & Natural Stone Series 840 series not issued Profile Metal Series 850 StoTherm Masonry Insulation System Ext.Cnr Horiz.Profiled Metal STM 850 StoTherm Masonry Insulation System Int.Cnr Horiz.Profiled Metal STM 851 StoTherm Masonry Insulation System Horizontal Junction/Horiz.Profiled Metal STM 852 StoTherm Masonry Insulation System Ext.Cnr Vertical Profiled Metal STM 853 StoTherm Masonry Insulation System Int.Cnr Vertical Profiled Metal STM 854 StoTherm Masonry Insulation System Horizontal Junction/Vertical Profiled Metal STM 855 StoTherm Panel EIFS 860 series not issued DISSIMILAR JOINERY Series 870 series not issued THESE DETAILS ARE ISSUED AS A GUIDE USING STANDARD BUILDING PRACTICES BASED ON THE NZBC. VARIOUS BUILDING COMPONENTS ARE DETAILED AND IT IS THE RESPONSIBILITY OF EACH TRADE INVOLVED TO ENSURE THAT THEIR PARTICULAR ELEMENTS ARE INSTALLED CORRECTLY. NOTE: REFER TO INDIVIDUAL MANUFACTURES FOR CURRENT DETAILS AND SPECIFICATIONS - SEE FOR CURRENT DETAILS. RBW DETAILS MUST BE ISSUED BY A; REGISTERED ARCHITECT, LICENSED DESIGNER OR CHARTERED ENGINEER PAGE 2 OF 2 INSULATION SYSTEM DRAWING REGISTER STM 002

3 STO CONCRETE BLOCK INSULATION SYSTEM SS207 INSULATION SYSTEM BRANZ APPRAISAL CERTIFICATE NO. 604 INCORPORATING: 1. PANEL (EPS) SELF-EXTINGUISHING PANEL MANUFACTURED TO AS1366 PT B (in 40mm, 50mm, 60mm, 80mm & 100mm thickness) 2. STOFLEXYL WATERPROOFING 18kg PAIL PLUS CEMENT EVALUATED BY BRANZ TO MEET AS/NZS4858 AS A WATERPROOFING MEMBRANE OVER RENDER SUBSTRATES IN ACCORDANCE WITH NZBC E2/AS1 3. MULTISCREED RENDER 25kg BAG BASECOAT RENDER TO STRAIGHTEN AND PROVIDE A SOLID BASECOAT 4. STOARMAT CLASSIC RENDER 23kg PAIL EUROPEAN FIBRE REINFORCED NON-CEMENT BASED CRACK RESISTANT RENDER USED WITH EUROPEAN MESH AS A REINFORCEMENT PLASTER 5. STOLIT K or MP COLOURED RENDER 25kg PAIL EUROPEAN FIBRE REINFORCED NON-CEMENT BASED COLOURED FINISHING RENDER AVAILABLE IN STOLIT K 1.0/1.5/2.0/3.0mm FLOAT FINISH & STOLIT MP, MP NATURAL & MILANO FINE FINISH 6. STOCOLOR : STOCOLOR MAXICRYL MATT FACADE PAINT 15lt PAIL : STOCOLOR LASTIC SATIN FACADE PAINT 15lt : STOCOLOR LOTUSAN FLAT MINERAL PAINT 15lt PAIL INSULATION SYSTEM INTRODUCTION STM 003

4 INSULATION SYSTEM - SS207 STO ADHESIVE MORTAR SELECTED PANELS - 40, 50, 60, 80 & 100mm THICK PANELS BASECOAT: STOLEVEL NOVO 4-5mm REINFORCEMENT: STOARMAT CLASSIC PLUS: STO EUROPEAN MESH REINFORCEMENT: STOARMAT CLASSIC FINISHING RENDER: STOLIT K or MP COLOURED FINISHING RENDER - 1.0, 1.5, 2.0 & 3.0mm FLOAT FINISH or MP SPOUNGE or MILANO SMOOTH COATING/STOCOLOR MAXICRYL MATT FACADE PAINT LASTIC SATIN FACADE PAINT LOTUSAN MINERAL RESIN PAINT NOTE: PANELS CAN BE COUNTERSUNK FROM 60mm PLUS THCKNESSES INSULATION SYSTEM INSULATION SYSTEM - ISOMETRIC SCALE 1:20 STM 100

5 PANELS - 600X1200mm or 1200X2400mm CAN BE USED FOR THICKNESSES UPTO 60mm. DETAIL IS SHOWING 600X1200mm PANELS TO JOINERY REVEALS USE STOFLEXYL WATERPROOFING WITH STOARMAT CLASSIC MESHED HEAD, SILL & JAMB DETAIL PANELS STOLEVEL NOVO BASECOAT STO MESH STO PREMESHED CORNER ANGLES STOARMAT CLASSIC MESH COAT STOLIT K or MP FINISHING RENDER NOTE: PANELS MUST BE STRETCHER BOND, STARTING FROM THE BOTTOM. TO BE GLUECOAT ADHERED & MECHANICALLY FIXED WITH ANCHORS. ALL PANEL CUTS SHALL BE MADE CAREFULLY TO ACHIEVE A TIGHT FIT. GLUECOAT ADHERED PANELS ARE TO BE MECHANICALLY FIXED WITH ANCHORS. ADHESIVE FOAM ANY GAPS AFTER FIXING INSULATION SYSTEM PANEL LAYOUT - ELEVATION STM 101

6 INSULATION SYSTEM PANEL & ANCHOR LAYOUT STM 102

7 1. SURFACE MOUNTED FIXINGS: INSULATION SYSTEM CAN USE FACE FIXED ANCHORS ON 40-60mm PANELS. NOTE FACED FIXED ANCHORS CAN EXHIBIT THERMAL BRIDGING SPOTS IN COLD WEATHER 2. INSULATION PANELS: 40mm R-VALUE mm R-VALUE mm R-VALUE mm R-VALUE mm R-VALUE mm R-VALUE mm R-VALUE mm R-VALUE mm R-VALUE mm R-VALUE COUNTER SUNK FIXINGS: INSULATION SYSTEM ANCHORS WITH STO INSULATING CAP ELIMINATES THERMAL BRIDGING SPOTS ON 50, 60, 80 & 100mm PANELS. NOTE IMPACT FIXINGS CAN ALSO BE USED ON 50,60 or 80mm PANELS USING A STO ROUTER TO CUT THE HOLE. 4. INTERIOR RENDER SYSTEM: SEE STO SELECTION OF INTERIOR RENDER SYSTEMS AND FINISHES. CONCRETE BLOCK (showing 20 series) STO ADHESIVE MORTAR PANEL (showing 100mm panel) ECOTWIST SELF EMBEDDING FIXING INSULATION RENDER SYSTEM ECOTWIST SELF EMBEDDING FIXING FOR 100mm TO 400mm PANEL - TO ELIMINATE THERMAL BRIDGING CONCRETE BLOCK (showing 20 series) STO ADHESIVE MORTAR PANEL (showing 80mm panel) ANCHOR INSULATION CAP INSULATION RENDER SYSTEM COUNTERSUNK ANCHORS IN 50, 60, 80 or 100mm PANEL - TO ELIMINATE THERMAL BRIDGING CONCRETE BLOCK (showing 20 series) STO ADHESIVE MORTAR PANEL (showing 40mm panel) IMPACT FIXING 1. 50mm MIN. PANELS REQUIRED FOR COUNTERSUNK FIXINGS IMPACT ANCHORS - FOR 40, 50, 60, 80MM PANEL INTERIOR STOLEVEL NOVO MESHED BASECOAT RENDER SELECTED STO FINISHING RENDER SYSTEM INSULATION SYSTEM FIXING STM 103

8 CONCRETE BLOCK WALL STO ADHESIVE RENDER INSULATION RENDER SYSTEM SELECTED PANEL COUNTERSUNK ANCHORS AS PER FIXING LAYOUT 8mm GAP 100mm STOFLEXYL BRUSH COAT FROM 100mm ABOVE FLOOR LEVEL TO 200mm BELOW BASE OF PANEL. STOFLEXYL TO BE MESHED WHERE BLOCKS EXTEND INTO THE GROUND. GL upvc FOOT TRAY. LEAVE AN 8mm GAP BEFORE FINISHING WITH MS SEALANT ON PEF ROD OVER PAVING FLOOR LEVELS mm TO PAVED GROUND LEVEL mm TO UNPAVED GROUND LEVEL INSULATION SYSTEM WALL/FOOTING JUNCTION STM 200

9 STO ADHESIVE RENDER INSULATION RENDER SYSTEM SELECTED PANEL COUNTERSUNK ANCHORS AS PER FIXING LAYOUT JOINT 50mm MIN. BELOW FLOOR LEVEL 50 STO FLEXYL WATERPROOFING BRUSH COAT BEFORE PANEL OVERLAY 150 NOTE: 1. BRUSH COAT CONCRETE WITH STO FLEXYL TO CONCRETE FOUNDATION 150mm MIN. ABOVE G.L 2. INSTALL POLYSTYRENE PLINTH BOARD ENSURING THE EPS SHEET IN GROUND IS FLEXYL COATED TO ALL SIDES3. IF XPS PLINTH BOARD USED, SURFACES TO BE RASPED PRIOR TO APPLICATION OF STOFLEXYL. NOTE: FOR CONCRETE BLOCK FOUNDATIONS STOFLEXYL MESH BLOCKS 3. APPLY STO FLEXYL BRUSH COAT OVER STOLEVELL NOVO BASE COAT FROM 150mm ABOVE GROUND TO 100mm PAST TERMINATION POINT STO FLEXYL MESHED CAPILLARY BREAK GL SELECTED PLINTH BOARD DRAINAGE MATERIAL FLOOR LEVELS mm TO PAVED GROUND LEVEL mm TO UNPAVED GROUND LEVEL MASNORY INSULATION SYSTEM BELOW GROUND INSULATION STM 201

10 STO PREMESHED CORNER STO ADHESIVE RENDER INSULATION RENDER SYSTEM SELECTED CONC.BLOCK SELECTED PANEL COUNTERSUNK ANCHORS AS PER FIXING LAYOUT. INTERIOR WITH SELECTED STO INTERIOR RENDER SYSTEM EXTERIOR INSULATION SYSTEM EXTERNAL CORNER - PLAN VIEW STM 300

11 EXTERIOR STO ADHESIVE RENDER INSULATION RENDER SYSTEM COUNTERSUNK ANCHORS AS PER FIXING LAYOUT SELECTED PANEL INTERIOR WITH SELECTED STO INTERIOR RENDER SYSTEM CONCRETE WALL INSULATION SYSTEM INTERNAL CORNER - PLAN VIEW STM 301

12 SELECTED CONC.BLOCK INSULATION RENDER SYSTEM SELECTED PANEL STO ADHESIVE RENDER INTERIOR WITH SELECTED STO INTERIOR RENDER SYSTEM EXTERIOR COUNTERSUNK ANCHORS 100mm EACH SIDE OF CONTROL JOINT AT 600mm CTRS MAX. ENGINEERED CONCRETE BLOCK CONTROL JOINT STO upvc CONTROL JOINT IN STOARMAT MESH COAT INSULATION SYSTEM VERTICAL CONTROL JOINT - PLAN VIEW STM 302

13 150 STOFLEXYL MESHED WATERPROOFING 150mm MIN.ABOVE & BELOW STAIRS WITH 50mm MIN.PAST PANEL ON STAIRS or UNDERTILE MEMBRANE BED PANELS IN STOFLEXYL MORTAR SELECTED CONCRETE BLOCK WALL 50mm APPLY STOFLEXYL MESHED BAND ON CONC.BLOCKS 150mm MIN. ABOVE AND 150mm BELOW STAIRS BEFORE BOXING - APPLY STOFLEXYL MESH, 50mm MIN.PAST INSULATION BEFORE RENDERING OR APPLYING TILE MEMBRANE STOFLEXYL WATERPROOFING MEMBRANE WALL CAPS, PARAPETS, BALUSTRADE TOPS JOINERY OPENINGS TIMBER OVERLAYS & SOFFITS OVERLAYING BLOCKS STAIRS ADJACENT GARDEN WALLS FOUNDATIONS INSULATION SYSTEM STAIR WATERPROOFING DETAIL STM 303

14 STO ADHESIVE RENDER INSULATION RENDER SYSTEM SELECTED PANEL COUNTERSUNK ANCHORS AS PER FIXING LAYOUT. 5 MIN.SLOPE TO OUTSIDE PIPE OR OTHER PENETRATION SLOPED DOWNWARD - TOWARD THE OUTSIDE 8/10mm SEALANT BEAD ON PEF ROD BETWEEN PIPE AND RENDER INTERIOR EXTERIOR INSULATION SYSTEM PIPE PENETRATION DETAIL (up to150mm) STM 350

15 INSULATION RENDER SYSTEM APPLY STO FLEXYL MESHED WATERPROOFING TO EXTERIOR REBATES BEFORE RENDERING TO LEAVE 10mm SEALANT JOINT STO PREMESHED DRIP EDGE MS SEALANT OVER STO JOINT SEAL TAPE TO PERIMETER OF METERBOX METER BOX AT HEAD MS SEALANT OVER STO JOINT SEAL TAPE WITH 2 x 20mm DRAINAGE OPENINGS AT SILL APPLY STO FLEXYL MESHED WATERPROOFING TO EXTERIOR REBATES OUT TO EXTERNAL PANEL FACE BEFORE PLASTERING TO LEAVE A 6-8mm SEALANT JOINT. METER BOX AT SILL INSULATION SYSTEM METER BOX STM 351

16 INTERIOR EXTERIOR STO ADHESIVE RENDER INSULATION RENDER SYSTEM SELECTED PANEL COUNTERSUNK ANCHORS AS PER FIXING LAYOUT. LIGHT FITTING WITH PLASTIC CONDUIT FOR WIRING FIXINGS WITH 50mm x3mm EPDM WASHERS USE STAINLESS STEEL PIPE SPACERS AT FIXINGS TAKING CARE TO AVOID CRUSHING EPS SHELL CONC.BLOCK WALL AMSONRY INSULATION SYSTEM LIGHT FITTING/FIXING DETAIL STM 352

17 INTERIOR EXTERIOR COUNTERSUNK ANCHORS AS PER FIXING LAYOUT. TAP FITTED SECURILY ON THREADED PIPE WITH WATERPROOF WASHER AND SEALED WITH MS SEALANT CUT SHELL TO FIT PIPES PIPE FIXED ONTO CONCRETE WITH SADDLE CLAMPS & TAPETS. FILL ANY GAPS WITH STO ADHESIVE FOAM. STO ADHESIVE RENDER SELECTED PANEL INSULATION RENDER SYSTEM SELECTED CONC.BLOCK INSULATION SYSTEM TAP FITTING/FIXING DETAIL STM 353

18 STO ADHESIVE RENDER INTERIOR 100mm MAX. NZBC D1 clause1.5.2 EXTERIOR SELECTED CONC.BLOCK INSTALL HANDRAIL PLATE FIXED OVER STO RENDER SYSTEM. FIXINGS THROUGH STAINLESS STEEL SPACERS TO AVOID CRUSHING EPS SHELL EPDM GASKET REQUIRED BETWEEN PLATE & RENDER TO PROVIDE WATERTIGHTNESS COUNTERSUNK ANCHORS AS PER FIXING LAYOUT. SELECTED PANEL INSULATION RENDER SYSTEM INSULATION SYSTEM HAND RAIL BRACKET/FIXING DETAIL STM 354

19 INTERIOR EXTERIOR DOWNPIPE CLIP - 1.2M CTRS FIXED WITH STO 40mm STO SPIRAL FIXING. DRILL HOLE FOR SPIRAL FIXING THROUGH RENDER ONLY - SCREW TO EPS PANEL SELECTED CONC.BLOCK NOTE: upvc or OTHER DOWNPIPE - SIZE REFER NZBC E1 Table 5 STO ADHESIVE RENDER COUNTERSUNK ANCHORS AS PER FIXING LAYOUT. SELECTED PANEL INSULATION RENDER SYSTEM NOTE: STO SPIRAL FIXINGS MAY BE USED TO SUPPORT OTHER LIGHTWEIGHT ITEMS SUCH AS LIGHTS & SECURITY FITTINGS HOWEVER SPIRAL FACE WEIGHT MUST NOT EXCEED 8kgs INSULATION SYSTEM DOWNPIPE SADDLE FIXING DETAIL STM 355

20 INTERIOR EXTERIOR STO ADHESIVE RENDER INSULATION RENDER SYSTEM SELECTED PANEL COUNTERSUNK ANCHORS AS PER FIXING LAYOUT. MS SEALANT TO HEAD & SIDES 5 MIN.SLOPE TO OUTSIDE FAN VENT COVER EXTRACTION PIPE (150mm MAX.) PIPE OR OTHER PENETRATION SLOPED DOWNWARD - TOWARD THE OUTSIDE MS SEALANT/PEF ROD AT PIPE JUNCTION (STO SEAL TAPE ON FLEXIBLE PIPES) SELECTED CONC.BLOCK INSULATION SYSTEM FAN VENT DETAIL STM 356

21 SELECTED CONC.BLOCK STO ADHESIVE RENDER APPLY STOFLEXYL MESHED WATERPROOFING TO EXTERNAL REBATES OUT OVER PANEL TO EXTERNAL CORNER STO PREMESHED DRIP EDGE MS SEALANT CONTINUOUS ACROSS HEAD & DOWN JAMBS APPLY STOFLEXYL IN TWO BRUSH COATS TO ALL INTERNAL REBATES OUT ONTO EXTERNAL REBATES PROPRIETARY ALU.WINDOW JOINERY APPLY STOFLEXYL MESHED WATERPROOFING TO EXTERNAL REBATES OUT OVER PANEL TO EXTERNAL CORNER TURN MESH UP REBATE EDGE ON JAMBS AND SILL SELECTED CONC.BLOCK INSULATION RENDER SYSTEM SELECTED PANEL INSULATION SYSTEM ALUMINIUM JOINERY - HEAD & SILL DETAIL STM 400

22 SELECTED CONC.BLOCK APPLY STOFLEXYL IN 2 BRUSH COATS ON INTERNAL REBATES OUT ONTO EXTERNAL REBATE PROPRIETARY ALU.WINDOW JOINERY MS SEALANT CONTINUOUS ACROSS HEAD & DOWN JAMBS APPLY STOFLEXYL MESHED WATERPROOFING TO EXTERIOR REBATES OUT OVER PANEL TO EXTERNAL CORNER STO ADHESIVE MORTAR SELECTED PANEL INSULATION RENDER SYSTEM INSULATION SYSTEM ALUMINIUM JOINERY - JAMB DETAIL STM 401

23 SELECTED CONC.BLOCK INSULATION RENDER SYSTEM APPLY STOFLEXYL MESHED WATERPROOFING TO EXTERNAL REBATES OUT OVER PANEL TO EXTERNAL CORNER STO PREMESHED DRIP EDGE APPLY MS SEALANT AROUND REBATE/JOINERY HEAD AND JAMBS AND FINISH WITH TIMBER TRIM WITH MS SEALANT STO 6mm upvc FINISHING EDGE IN BASECOAT RENDER. MS SEALANT CONTINUOUS ACROSS HEAD & DOWN JAMBS WITH TIMBER TRIM APPLY STOFLEXYL IN TWO BRUSH COATS TO ALL INTERNAL BLOCK REBATES OUT ONTO EXTERNAL REBATE TIMBER JOINERY PROFILES AS PER NZS 3610 H3.1 TIMBER PACKERS ON DPC. IF REQUIRED FIT JOINERY SUPPORT BAR APPLY STOFLEXYL MESHED WATERPROOFING TO EXTERNAL REBATES OUT OVER PANEL TO EXTERNAL CORNER SELECTED CONC.SILL BLOCK INSULATION SYSTEM TIMBER JOINERY - HEAD & SILL DETAIL STM 402

24 SELECTED CONC.BLOCK AIR SEAL OVER BACKING ROD STOFLEXYL CONTINUES ON INTERNAL PORTION OF REBATE TIMBER JOINERY PROFILES AS PER NZS 3610 FIX TIMBER BEAD AROUND JOINERY HEAD AND JAMB WITH MS SEALANT STO 6mm upvc FINISHING EDGE IN BASECOAT RENDER. MS SEALANT CONTINUOUS ACROSS HEAD & DOWN JAMBS WITH TIMBER TRIM APPLY STOFLEXYL MESHED WATERPROOFING TO EXTERNAL REBATES OUT OVER PANEL TO EXTERNAL CORNER INSULATION RENDER SYSTEM INSULATION SYSTEM TIMBER JOINERY - JAMB DETAIL STM 403

25 STO ADHESIVE RENDER SELECTED CONC.BLOCK PREPARE REBATES AND BRUSH APPLY STOFLEXYL TO INTERNAL REBATE. STOFLEXYL WATERPROOFING TOMESHED EXTERNAL REBATE OUT OVER PANEL TO EXTERNAL CORNER STO PREMESHED DRIP EDGE MS SEALANT CONTINUOUS ACROSS HEAD & DOWN JAMBS TIMBER SILL - ADJUST REBATE/ PACKER TO SUIT FLOOR COVERINGS PROPRIETARY ALU.DOOR JOINERY 10mm MIN. PREPARE REBATES AND BRUSH APPLY STOFLEXYL WATERPROOFING ON INSITU CONCRETE OR WITH MESH ON LINE OF CONCRETE BLOCK & FOUNDATION - SHOWN DASHED INSULATION RENDER SYSTEM - 150mm MIN.FLOOR SLAB to GROUND LEVEL 100mm MIN.FLOOR SLAB to PAVING INSULATION SYSTEM ALU.JOINERY-DOOR HEAD & THRESHOLD DETAIL STM 404

26 INSULATION RENDER SYSTEM OVER INSULATION PANEL SELECTED CONC.BLOCK PREPARE REBATES AND BRUSH APPLY STOFLEXYL TO INTERNAL REBATE. STOFLEXYL WATERPROOFING TOMESHED EXTERNAL REBATE OUT OVER PANEL TO EXTERNAL CORNER STO PREMESHED DRIP EDGE STO 6mm upvc FINISHING EDGE IN BASECOAT RENDER. MS SEALANT CONTINUOUS ACROSS HEAD & DOWN JAMBS WITH TIMBER TRIM FIX TIMBER BEAD AROUND JOINERY HEAD AND JAMB WITH MS SEALANT AIR SEAL OVER BACKING ROD TIMBER DOOR JOINERY PROFILES AS PER NZS 3610 * REBATE TO SUIT SILL PROFILE * LINE OF CONCRETE BLOCK & FOUNDATION - SHOWN DASHED 50 APPLY TWO COATS OF STO FLEXYL WATERPROFFING TO ALL REBATES OVER BASECOAT 50mm MIN.DOWN WALL INSULATION SYSTEM TIMBER DOOR JOINERY - HEAD & SILL DETAIL STM 405

27 STO ADHESIVE RENDER SELECTED CONC.BLOCK 20mm + APPLIED TO FACE OF BLOCK REBATE WITH STO FLEXYL ADHESIVE 5 10 APPLY STOFLEXYL MESHED WATERPROOFING TO EXTERNAL REBATES OUT OVER PANEL TO EXTERNAL CORNER STO PREMESHED DRIP EDGE 84X16 FIBRE CEMENT ADHERED TO CONCRETE BLOCK REBATE USING GLUECOAT APPLIED WITH 10MM NOTCH TROWEL AND THEN MECHANICALLY FIXED 10 MS SEALANT CONTINUOUS ACROSS HEAD & DOWN JAMB PROPRIETARY ALU.WINDOW JOINERY 20mm + APPLIED TO FACE OF BLOCK REBATE WITH STO FLEXYL ADHESIVE 5 APPLY STOFLEXYL MESHED WATERPROOFING TO EXTERNAL REBATES OUT OVER PANEL TO EXTERNAL CORNER SELECTED CONC.BLOCK INSULATION RENDER SYSTEM SELECTED PANEL NOTE: FIBRE CEMENT FACINGS AVAILABLE FROM JAMES HARDIE INSULATION SYSTEM 20mm POLYSTYRENE TO RECESS ALU. JOINERY - HEAD & SILL DETAIL STM 406

28 SELECTED CONC. BLOCK PROPRIETARY ALU.WINDOW JOINERY 84X16 FIBRE CEMENT TRIM ADHERED TO CONCRETE BLOCK REBATE USING GLUECOAT APPLIED WITH 10MM NOTCH TROWEL AND THEN MECHANICALLY FIXED 5 10 MS SEALANT CONTINUOUS ACROSS HEAD & DOWN JAMB 20mm + APPLIED TO FACE OF BLOCK REBATE WITH STO FLEXYL ADHESIVE STO ADHESIVE RENDER INSULATION RENDER SYSTEM APPLY STOFLEXYL MESHED WATERPROOFING TO EXTERNAL REBATES OUT OVER PANEL TO EXTERNAL CORNER NOTE: FIBRE CEMENT FACINGS AVAILABLE FROM JAMES HARDIE INSULATION SYSTEM 20mm POLYSTYRENE TO RECESS ALU. JOINERY - JAMB DETAIL STM 407

29 STO ADHESIVE RENDER SELECTED CONC.BLOCK 40mm + APPLIED TO FACE OF BLOCK REBATE WITH STO FLEXYL ADHESIVE 5 40 APPLY STOFLEXYL MESHED WATERPROOFING TO EXTERNAL REBATES OUT OVER PANEL TO EXTERNAL CORNER 10 2 / 84x16 FIBRECEMENT TRIM LAMINATED TOGETHER AND ADHERED TO CONCRETE BLOCK REBATE USING GLUECOAT APPLIED WITH 10MM NOTCH TROWEL AND THEN MECHANICALLY FIXED 5 10 STO PREMESHED DRIP EDGE MS SEALANT CONTINUOUS ACROSS HEAD & DOWN JAMB PROPRIETARY ALU.WINDOW JOINERY 40mm + APPLIED TO FACE OF BLOCK REBATE WITH STO FLEXYL ADHESIVE APPLY STOFLEXYL MESHED WATERPROOFING TO EXTERNAL REBATES OUT OVER PANEL TO EXTERNAL CORNER SELECTED CONC.BLOCK INSULATION RENDER SYSTEM SELECTED PANEL NOTE: FIBRE CEMENT FACINGS AVAILABLE FROM JAMES HARDIE INSULATION SYSTEM 40mm POLYSTYRENE TO RECESS ALU. JOINERY - HEAD & SILL DETAIL STM 408

30 SELECTED CONC. BLOCK PROPRIETARY ALU.WINDOW JOINERY 2/84 x 16 FIBRE CEMENT TRIM LAMINATED TOGETHER AND ADHERED TO CONCRETE BLOCK REBATE USING GLUECOAT APPLIED WITH 10MM NOTCH TROWEL AND THEN MECHANICALLY FIXED 5 10 MS SEALANT CONTINUOUS ACROSS HEAD & DOWN JAMBS 40mm + APPLIED TO FACE OF BLOCK REBATE WITH STO FLEXYL ADHESIVE STO ADHESIVE RENDER INSULATION RENDER SYSTEM APPLY STOFLEXYL MESHED WATERPROOFING TO EXTERNAL REBATES OUT OVER PANEL TO EXTERNAL CORNER NOTE: FIBRE CEMENT FACINGS AVAILABLE FROM JAMES HARDIE INSULATION SYSTEM 40mm POLYSTYRENE TO RECESS ALU. JOINERY - JAMB DETAIL STM 409

31 PROVIDE SEPARATION (ROOF UNDERLAY) UNDER METAL CAPPING OVER 15mm H3 PLY/DPC 5 PRE FINISHED METAL CAPPING TO PARAPET WITH 5 MIN.FALL SIDE FIX ONLY Z Z REFER TABLE 7 - E2/AS1 COUNTERSUNK ANCHORS AS PER FIXING LAYOUT. SELECTED CONC. BLOCK SERIES STO ADHESIVE RENDER INSULATION RENDER SYSTEM INSULATION PANEL INSULATION SYSTEM PARAPET/METAL FLASHING DETAIL STM 500

32 10 CAP FIXED WITH STO ADHESIVE MORTAR STOFLEXYL MESHED WATERPROOFING OVER BASECOAT TO PARAPET/BALUSTRADE TOP & 100mm MIN.PAST PANEL JOINT SELECTED CONC.BLOCK STO ADHESIVE RENDER COUNTERSUNK ANCHORS AS PER FIXING LAYOUT INSULATION RENDER PLASTER SYSTEM SELECTED PANEL INSULATION SYSTEM PLASTERED PARAPET/BALUSTRADE DETAIL STM 501

33 PROVIDE SEPARATION (ROOF UNDERLAY) UNDER METAL CAPPING OVER 15mm H3 PLY Z 5 Z PRE FINISHED METAL CAPPING TO PARAPET WITH 5 MIN.FALL REFER TABLE 7 - E2/AS1 ROOF MEMBRANE TO LAP OVER PARAPET SELECTED CONC.BLOCK COUNTERSUNK ANCHORS AS PER FIXING LAYOUT ROOF SCREED TO A MIN FALL OF 1.5 STO ADHESIVE RENDER INSULATION RENDER SYSTEM SELECTED PANEL CONCRETE ROOF SLAB INSULATION SYSTEM PARAPET/ROOF/WALL DETAIL STM 502

34 10 CAP FIXED WITH STO ADHESIVE MORTAR 50 25mm MIN.PIR INSULATION BEHIND MEMBRANE MECHANICALLY FIXED AND SEALANT 50 STOFLEXYL MESHED WATERPROOFING TO PARAPET/BALUSTRADE TOP & 50mm MIN.PAST PANEL JOINT SELECTED MEMBRANE ON PIR INSULATION TO MIN 1:5 FALL 100 COUNTERSUNK ANCHORS AS PER FIXING LAYOUT SELECTED CONC. BLOCK STO ADHESIVE RENDER CONCRETE ROOF SLAB INSULATION RENDER SYSTEM SELECTED PANEL 25mm MIN PIR INSULATION BEHIND MEMBRANE METAL FLASHING MECHANICALLY FIXED WITH FIXINGS AT TO MEMBRANE JUNCTION INSULATION SYSTEM INSULATED ROOF / DECK TO WALLS STM 503

35 ROOF STRUCTURE - REFER NZS 3604 SELECTED ROOFING OVER ROOF UNDERLAY VARIES REFER MANUFACTURER SOFFIT FRAMING INTERIOR SELECTED CONC.BLOCK SOFFIT LINING MS SEALANT OVER PANEL PRIOR TO RENDERING STO ADHESIVE RENDER SELECTED PANEL INSULATION RENDER SYSTEM NOTE: EAVE FLASHING REQUIRED WHERE ROOF SLOPE IS 10 or LESS SOFFIT WIDTH IS 100mm or LESS WIND ZONES ARE VERY HIGH or EXTRA HIGH INSULATION SYSTEM FLAT SOFFIT/WALL JUNCTION SCALE 1:10 STM 600

36 SELECTED ROOFING OVER ROOF UNDERLAY REFER MANUFACTURER ROOF STRUCTURE - REFER NZS 3604 INTERIOR SOFFIT LINING MS SEALANT OVER PANEL STO ADHESIVE RENDER SELECTED PANEL INSULATION RENDER SYSTEM SELECTED CONC.BLOCK NOTE: EAVE FLASHING REQUIRED WHERE ROOF SLOPE IS 10 or LESS SOFFIT WIDTH IS 100mm or LESS WIND ZONES ARE VERY HIGH or EXTRA HIGH SCALE 1:10 INSULATION SYSTEM RAKING SOFFIT/WALL JUNCTION STM 601

37 SELECTEDROOFING OVER ROOF UNDERLAY SELECTED FIBRE CEMENT SOFFIT LINING E2/AS1 COMPLIANT FLASHING 6mm MAX.GAP WITH MS SEALANT or STO JOINT SEAL TAPE 20 SERIES CONCRETE WALL INSULATION RENDER SYSTEM NOTE: MAX.ANGLE OF SOFFIT RESTRICTED TO BETWEEN SOFFITS ARE FIXED AFTER RENDERING SCALE 1:10 INSULATION SYSTEM RAKING SOFFIT (REVERSED) STM 602

38 SELECTED ROOFING OVER ROOF UNDERLAY REFER MANUFACTURER ROOF STRUCTURE - REFER NZS 3604 INTERIOR MS SEALANT AND PEF ROD SELECTED CONC.BLOCK STO ADHESIVE RENDER SELECTED PANEL INSULATION RENDER SYSTEM NOTE: EAVE FLASHING REQUIRED WHERE ROOF SLOPE IS 10 or LESS SOFFIT WIDTH IS 100mm or LESS WIND ZONES ARE VERY HIGH or EXTRA HIGH SCALE 1:10 INSULATION SYSTEM FACE FIXED FASCIA STM 603

39 SELECTED ROOFING OVER ROOF UNDERLAY PURLIN - REFER NZS 3604 E2/AS1 COMPLIANT FLASHING LAP - REFER NZBC, TABLE 7 E2/AS1 MIN.2 x crests 50/90 M12 BOLT FIXING RAKING WALL PLATE ON DPC FLYING RAFTER SOFFIT LINING H3.1 FASCIA/BARGE BOARD MS SEALANT OVER PANEL STO ADHESIVE RENDER INSULATION RENDER SYSTEM SELECTED CONC.BLOCK SERIES (shown 20 series conc.block) INSULATION SYSTEM BARGE WITH OVERHANG STM 700

40 STO upvc END CAP TO PANEL 2 PART METAL FLASHING MECHANICALLY FIXED TO WALL THROUGH BOTH FLASHINGS 25mm MIN. PIR INSULATION Refer E2/AS1 table min 50mm 100 CAP FIXED WITH STO ADHESIVE MORTAR STOFLEXYL MESHED WATERPROOFING OVER BASECOAT TO PARAPET/BALUSTRADE TOP & 100mm MIN.PAST PANEL JOINT TIMBER ROOF STRUCTURE AS PER NZS PART METAL FLASHING MECHANICALLY FIXED AT JUNCTION TO PANEL SELECTED CONCRETE BLOCK STO ADHESIVE RENDER SELECTED PANEL INSULATION RENDER SYSTEM INSULATION SYSTEM PARALLEL APRON FLASHING AT PARAPET STM 701

41 PURLIN - REFER NZS 3604 SELECTED ROOFING OVER ROOF UNDERLAY VARIES REFER MANUFACTURER M12 BOLT FIXING AS PER NZS 3604 SOFFIT FRAMING H3.1 FASCIA BOARD SOFFIT LINING MS SEALANT 6-8mm (before plastering) COUNTERSUNK ANCHORS AS PER FIXING LAYOUT STO ADHESIVE RENDER INSULATION RENDER SYSTEM SELECTED CONC.BLOCK WALL NOTE: EAVE FLASHING REQUIRED WHERE ROOF SLOPE IS 10 o OR LESS SOFFIT WIDTH IS 100mm OR LESS WIND ZONES ARE VERY HIGH or EXTRA HIGH INSULATION SYSTEM EAVES WITH OVERHANG STM 702

42 SELCTED ROOFING OVER ROOF UNDERLAY 125 PURLIN - REFER NZS 3604 CEILING BATTEN M12 BOLT FIXING 35 COMPLIANT EAVE FLASHING/E2/AS1 H3.1 FASCIA BOARD 50 STO upvc SOFFIT EDGE 50mm MIN. COVER TO CLADDING & WITH STO JOINT SEAL or MS SEALANT OVER PEF ROD COUNTERSUNK ANCHORS AS PER FIXING LAYOUT STO ADHESIVE RENDER INSULATION RENDER SYSTEM SELECTED CONC.BLOCK NOTE: EAVE FLASHING REQUIRED WHERE ROOF SLOPE IS 10 o OR LESS SOFFIT WIDTH IS 100mm OR LESS WIND ZONES ARE VERY HIGH or EXTRA HIGH INSULATION SYSTEM EAVES WITH NO OVERHANG STM 703

43 50mm flexyl 100mm Upstand 35 Refer E2/AS1 table 7 STO ADHESIVE RENDER INSULATION RENDER SYSTEM SELECTED CONC.BLOCK BRUSH STOFLEXYL OVER BLOCKS 50mm MIN. 2 PART METAL FLASHING MECHANICALLY FIXED THROUGH BOTH FLASHINGS OVER 25mm PIR INSULATION TIMBER ROOF STRUCTURE AS PER NZS 3604 NOTE: INSTALL DIVERTER FLASHING AT ROOF/GUTTER JUNCTION INSULATION SYSTEM PARALLEL APRON FLASHING STM 704

44 50 35 STO ADHESIVE RENDER SELECTED PANEL WITH FOOT TRAY INSULATION RENDER SYSTEM SELECTED CONC.BLOCK BRUSH STOFLEXYL OVER BLOCKS 50mm MIN. 2 PART METAL FLASHING MECHANICALLY FIXED TO WALL THROUGH BOTH FLASHINGS Refer E2/AS1 Table 7 25mm MIN.PIR INSULATION TIMBER ROOF STRUCTURE AS PER NZS 3604 INSULATION SYSTEM TRANSVERSE APRON FLASHING STM 705

45 SELECTED PANEL STO ADHESIVE RENDER INSULATION RENDER SYSTEM SELECTED CONC.BLOCK 50mm flexyl 100mm upstand PART METAL ROOF FLASHING MECHANICALLY FIXED TO WALL THROUGH BOTH FLASHINGS 80mm MIN. 80mm MIN. TIMBER ROOF STRUCTURE AS PER NZS 3604 INSULATION SYSTEM PARALLEL ROOF HIDDEN GUTTER STM 705

46 SELECTED MEMBRANE FINISH OVER H3"C" FACED PLYWOOD LAID TO A 1:30MIN.FALL GLUE & SCREW TO TIMBER FRAMING, ALL EDGES SUPPORTED MIN. 5mm RADIUS TO PLYWOOD 50mm MIN.LAP - REFER E2/AS1 50 STO upvc END CAP H3.1 FASCIA BOARD. MS SEALANT AND PEF ROD or STO JOINT SEAL TAPE STO ADHESIVE RENDER INSULATION RENDER SYSTEM SELECTED CONC.BLOCK INSULATION SYSTEM FACE FIXED FASCIA/MEMBRANE ROOF STM 707

47 INSULATION RENDER SYSTEM SELECTED PANEL STO ADHESIVE RENDER STO upvc FINISHING EDGE MS SEALANT OVER PEF ROD STO upvc END CAP E2/AS1 COMPLIANT FLASHING NOMINAL H3.1 TIMBER BATTEN /DPC SELECTED CONC.BLOCK SERIES SELECTED HORIZONTAL WEATHERBOARDS OVER 20mm DRAINED CAVITY WALL UNDERLAY INSULATION SYSTEM EXTERNAL CORNER STM 800

48 10mm OFFSET TO AVOID CONTROL JOINT INTERIOR RENDER SYSTEM SELECTED CONC.BLOCK COMPLIANT E2/AS1 CORNER FLASHING SELECTED INSULATION PANEL 50 STO ADHESIVE RENDER INSULATION RENDER SYSTEM STO upvc STICK ON CONNECTOR WALL UNDERLAY SELECTED HORIZONTAL WEATHERBOARDS OVER 20mm DRAINED CAVITY INSULATION SYSTEM INTERNAL CORNER STM 801

49 5 SELECTED FLOORING BEVEL-BACK WEATHERBOARDS TO NZS 3617 OVER 20mm DRAINED CAVITY CEILING BATTENS JOISTS - REFER NZS3604 FOR SIZE WALL PLATE ON DPC FLASHING TAPE OVER CAVITY CLOSURE upvc END CAP E2/AS1 COMPLIANT FLASHING STO ADHESIVE RENDER SELECTED PANEL INSULATION RENDER SYSTEM IN EXTRA HIGH WIND ZONES INCREASE FLASHING COVER TO 60mm AND INSTALL A RIGID AIR BARRIER INSULATION SYSTEM HORIZONTAL JUNCTION STM 802

50 INSULATION RENDER SYSTEM SELECTED PANEL STO ADHESIVE MORTAR SELECTED CONC.BLOCK DPC STO upvc MESHED CORNER ANGLE INSULATION RENDER SYSTEM STO ADHESIVE RENDER SELECTED PANEL BACK FLASHING STO upvc END CAP STO JOINT SEAL OR PEF ROD 6mm MIN.GAP MS SEALANT E2/AS1 COMPLIANT FLASHING PROFILED FOAM CLOSURE STRIP UNDER CLADDING NOMINAL H3.1 TIMBER BATTEN WALL UNDERLAY HORIZONTAL PROFILED METAL WALL CLADDING INSULATION SYSTEM EXTERNAL CORNER/HORIZ.PROFILED METAL STM 850

51 10mm OFFSET TO AVOID CONTROL JOINT STO INTERIOR RENDER SYSTEM SELECTED CONC.BLOCK E2/AS1 COMPLIANT FLASHING SELECTED PANEL STO ADHESIVE RENDER INSULATION RENDER SYSTEM STO upvc END CAP + STO JOINT SEAL OR PEF ROD 6mm MIN.GAP MS SEALANT E2/AS1 COMPLIANT FLASHING PROFILED FOAM CLOSURE STRIP UNDER CLADDING NOMINAL H3.1 TIMBER BATTEN HORIZONTAL PROFILED METAL WALL CLADDING INSULATION SYSTEM INTERNAL CORNER/HORIZ.PROFILED METAL STM 851

52 SELECTED FLOORING HORIZONTAL PROFILED METAL CLADDING WALL UNDERLAY 20mm DRAINED & VENTED CAVITY CEILING BATTENS JOISTS - REFER NZS3604 CLOSE CAVITY WITH E2/AS1 COMPLIANT FLASHING TAPED TO BUILDING WRAP 50 6 WALL PLATE ON DPC STO upvc END CAP 15 COMPLIANT E2/AS1 FLASHING STO ADHESIVE RENDER SELECTED CONC.BLOCK SELECTED PANEL INSULATION RENDER SYSTEM IN EXTRA HIGH WIND ZONES INCREASE FLASHING COVER TO 60mm AND INSTALL A RIGID AIR BARRIER INSULATION SYSTEM HORIZONTAL JUNCTION/HORIZ.PROFILED METAL STM 852

53 INSULATION RENDER SYSTEM SELECTED PANEL STO ADHESIVE RENDER SELECTED CONC.BLOCK STO upvc MESHED CORNER ANGLE E2/AS1 COMPLIANT FLASHING STO upvc END CAP STO JOINT SEAL or PEF ROD 6mm MIN.GAP MS SEALANT E2/AS1 COMPLIANT FLASHING WALL UNDERLAY VERTICAL PROFILED METAL WALL CLADDING INSULATION SYSTEM EXT.CORNER/VERTICAL PROFILED METAL STM 853

54 STO INTERIOR PLASTER SYSTEM 10mm OFFSET TO AVOID CONTROL JOINT SELECTED CONC.BLOCK STO ADHESIVE RENDER SELECTED PANEL INSULATION RENDER SYSTEM STO upvc END CAP STO SEAL JOINT OVER BACKING ROD E2/AS1 COMPLIANT FLASHING 50 EXPANSION GAP 10mm MIN. (recommended) DPC WALL UNDERLAY VERTICAL PROFILED METAL WALL CLADDING 50 min.2 crests INSULATION SYSTEM INT.CORNER/VERTICAL PROFILED METAL STM 854

55 SELECTED FLOORING VERTICAL PROFILED METAL CLADDING WALL UNDERLAY CEILING BATTENS SELECTED CONC.BLOCK JOISTS - REFER NZS3604 FOR SIZE WALL PLATE ON DPC FLEXIBLE TAPE LAPPED OVER FLASHING UPSTAND STO upvc END CAP E2/AS1 COMPLIANT FLASHING STO ADHESIVE RENDER SELECTED PANEL INSULATION RENDER SYSTEM IN EXTRA HIGH WIND ZONES INCREASE FLASHING COVER TO 60mm AND INSTALL A RIGID AIR BARRIER INSULATION SYSTEM HORIZ.JUNCTION/VERTICAL PROFILED METAL STM 855