Nello is a Veteran Owned Small Business located just north of the Washington, DC Capital Beltway.

Size: px
Start display at page:

Download "Nello is a Veteran Owned Small Business located just north of the Washington, DC Capital Beltway."

Transcription

1 Architectural Walls

2 Nello Wall Systems designs, manufactures, and installs Architectural Walls, and has been providing environmentally friendly, flexible office solutions for over 35 years. Nello Architectural Walls set the standard for sustainability; the first Nello wall was designed by Frank Gehry in 973, it has since been reconfigured and reused many different times, and is still in use today. Nello is a Veteran Owned Small Business located just north of the Washington, DC Capital Beltway. Nello has the experience, knowledge, and low-overhead, competitive-cost advantage to make your project a success.

3 Nello s glass Architectural Walls strike the perfect balance between storefront-style visual impact and long term ease of mobility. Interior segmented fabric walls improve sound absorption while providing true tackable functionality.

4 Whether creating a public-facing customer service space, a staff conference room, or a suite of executive offices, Nello s glass Architectural Walls can be configured in a limitless array of colors, patterns, and textures to suit any need.

5 Wood veneer panels can be used to accent or define a dramatic and powerful private space. Painted MDF, (available formaldehyde-free, with high-recycled content), is a durable solution for high traffic areas. Tackable-fabric, self-healing walls epitomize ergonomic efficiency for taskoriented desk spaces. In any finish format, Nello s Architectural Walls represent the best return on investment for a flexible, ever-evolving office environment.

6 Nello Architectural Walls offer your design team multiple opportunities for LEED Credits. In fact, at the GSA Headquarters Swingspace, Nello Walls contributed to a LEED Platinum certification, (as shown). Beyond the LEED initiative, Nello Architectural Walls have repeatedly been chosen by forward-looking designers seeking the most sustainable solution for an easily reconfigurable office floor plan. Nello has consistently proven its ability to successfully complete large scale environmentally sensitive projects while exceeding budget and lead-time expectations.

7 Nello strives to continually improve, refine, and even reengineer its Architectural Walls so that it can deliver the best product to its customers. If you have a unique design vision in mind, Nello is always intrigued by, and well positioned to excel at, Build to Spec Opportunities. Nello Wall Systems 6685, Santa Barbara Court, Elkridge MD 2075 P: F:

8 3" PANEL WIDTH SOLID PANEL SECTION /2" = " AW-SP- Solid Panel /2" Recessed Connection

9 3" 2 " 2 SOLID PANEL- STRAIGHT CONNECTION SECTION /2" = " AW-SP-SC-2 Solid Panel - Straight Connection /2" Recessed Connection 2

10 3" 3" 3" 2 " 3 SOLID PANEL - 2 WAY CONNECTION SECTION /2" = " AW-SP-2WC-3 Solid Panel - 2 Way Connection /2" Recessed Connection 3

11 3" 3" 3" 2 " 3" 2 " 4 SOLID PANEL - 3 WAY CONNECTION SECTION /2" = " AW-SP-3WC-4 Solid Panel - 3 Way Connection /2" Recessed Connection 4

12 3" 3" 3" 3" 5 SOLID PANEL - 4 WAY CONNECTION SECTION /2" = " AW-SP-4WC-5 Solid Panel - 4 Way Connection /2" Recessed Connection 5

13 4" 3" PANEL WIDTH 6 GLAZED PANEL SECTION /2" = " AW-GP-6 Glazed Panel /2" Recessed Connection 6

14 2 " 3" 3" 7 GLAZED PANEL - STRAIGHT CONNECTION SECTION /2" = " AW-GP-SC-7 Glazed Panel - Straight Connection /2" Recessed Connection 7

15 3" 2 " 2 " 3" 8 GLAZED PANEL - 2 WAY CONNECTION SECTION /2" = " AW-GP-2WC-8 Glazed Panel - 2 Way Connection /2" Recessed Connection 8

16 3" 2 " 3" 2 " 9 GLAZED PANEL - 3 WAY CONNECTION SECTION /2" = " AW-GP-3WC-9 Glazed Panel - 3 Way Connection /2" Recessed Connection 9

17 3" 0 GLAZED PANEL - 4 WAY CONNECTION SECTION /2" = " AW-GP-4WC-0 Glazed Panel - 4 Way Connection /2" Recessed Connection 0

18 3" SOLID PANEL - WALL CONDITION SECTION /2" = " AW-SP-WC- Solid Panel - Wall Condition /2" Recessed Connection

19 3" 2 GLAZED PANEL - WALL CONDITION SECTION /2" = " AW-GP-WC-2 Glazed Panel - Wall Condition /2" Recessed Connection 2

20 3" 3 SOLID PANEL - CEILING CONDITION SECTION /2" = " AW-SP-CC-3 Solid Panel - Ceiling Condition /2" Recessed Connection 3

21 3" 4" 4 SOLID PANEL - FLOOR CONDITION SECTION /2" = " AW-SP-FC-4 Solid Panel - Floor Condition /2" Recessed Connection 4

22 3" 5 GLAZED PANEL - CEILING CONDITION SECTION /2" = " AW-GP-CC-5 Glazed Panel - Ceiling Condition /2" Recessed Connection 5

23 3" 4" 6 GLAZED PANEL - FLOOR CONDITION SECTION /2" = " AW-GP-FC-6 Glazed Panel - Floor Condition /2" Recessed Connection 6

24 OPTIONAL - LIGHT SWITCH 3" 3-/2" DOOR UNIT WIDTH /4" = " 7 3" DOOR FRAME SECTION /2" = " AW-3DF-7 3" Door Frame /2" Recessed Connection 7

25 2 " 3 4 " 3" 2" 2" DOOR UNIT WIDTH /4" = " 8 /4" DOOR FRAME SECTION /2" = " AW-.25DF-8 /4" Door Frame /2" Recessed Connection 8

26 UNIT HEIGHT 9 BARN DOOR SECTION-A /2" = " AW-BD-SA-9 Barn Door /2" Recessed Connection 9

27 TRACK 78-3/4" LONG DOOR UNIT WIDTH DOOR OPENING 3/6"- /4" GLASS DOOR WIDTH FINISHED 3/4" BARN DOOR LINE OF FASCIA ABOVE DOOR ROLLER ASSEMBLY 3" 20 BARN DOOR / 3" DOOR FRAME SECTION-B /4" = " AW-BD-SB-3-20 Barn Door - 3" Door Frame /2" Recessed Connection 20

28 /4" TRACK 78-3/4" LONG DOOR UNIT WIDTH DOOR OPENING 3/6"- /4" GLASS DOOR WIDTH FINISHED 3/4" BARN DOOR LINE OF FASCIA ABOVE DOOR ROLLER ASSEMBLY 3" 2 BARN DOOR / /4" DOOR FRAME SECTION-B2 /4" = " AW-BD-SB Barn Door - /4" Door Frame /2" Recessed Connection 2

29 ELECTRICAL CONDUIT FACTORY INSTALLED ELECTRICAL BOX 4" 8" AFF 22 FACTORY INSTALLED ELECTRICAL BOX SECTION /2" = " AW-EB-22 Electrical Box Condition /2" Recessed Connection 22

30 /2" CONDUIT UNIT HEIGHT FACTORY INSTALLED LIGHT SWITCH ELECTRIC BOX 2"W x 3"H x 2-3/4"D 48"AFF 23 SWING DOOR / LIGHT BOX SECTION /4" = " AW-SDF-LB-22 SWING DOOR FRAME / LIGHT BOX /2" Recessed Connection 23

31 DOOR UNIT WIDTH 48" AFF 24 SWING DOOR / LIGHT BOX ELEVATION /6" = " AW-SDF-LB-22A SWING DOOR FRAME / LIGHT BOX /2" Recessed Connection 24

32 UNIT WIDTH 3" FACTORY INSTALLED LIGHT SWITCH ELECTRIC BOX 2"W x 3"H x 2-3/4"D 25 SWING DOOR / LIGHT BOX SECTION /4" = " AW-SDF-LB-22B SWING DOOR FRAME / LIGHT BOX /2" Recessed Connection 25

33 3" 4" FACTORY INSTALLED POWER TRACK 26 SOLID PANEL - POWER TRACK SECTION /2" = " AW-PT-23 Raceway Power Track 26

34 4 " 3" 27 TYP.HORIZONTAL REVEAL SECTION /2" = " AW-HR-27 TYP. HORIZONTAL REVEAL 27

35 INTEGRATED HORIZONTAL FURNITURE HANGER BAR. TYPE DIFFERS BY MANUFACTURER INTEGRATED HORIZONTAL FURNITURE HANGER BAR. TYPE DIFFERS BY MANUFACTURER 27-3/4 70" 28 SOLID PANEL SECTION NTS DRAWING NAME: AW-SP-28 ARCHITECTURAL WALLS SOLID PANEL FURNITURE HANGER DRAWING NO. 28

36 INTEGRATED HORIZONTAL FURNITURE HANGER BAR. TYPE DIFFERS BY MANUFACTURER INTEGRATED HORIZONTAL FURNITURE HANGER BAR. TYPE DIFFERS BY MANUFACTURER 27-3/4 70" 29 CLEARSTORY PANEL SECTION NTS DRAWING NAME: AW-CP-29 ARCHITECTURAL WALLS CLEARSTORY PANEL FURNITURE HANGER DRAWING NO. 29

37 WINDOW MULLION PAINTED WALL CHANNEL 3"Wide PAINTED FILLER WINDOW SILL PAINTED WALL CHANNEL FABRIC PANEL 3" 32a FABRIC PANEL - TYP.WINDOW SILL- SOLUTION () PLAN NTS DRAWING NAME: AW-SP-32a ARCHITECTURAL WALLS FABRIC PANEL TYP.WINDOW SILL-SOLUTION() DRAWING NO. 32a

38 WINDOW SILL BULKHEAD PAINTED CEILING CHANNEL PAINTED WALL CHANNEL PAINTED FILLER WINDOW MULLION FABRIC PANEL PAINTED WALL CHANNEL 4" COVE BASE 32 FABRIC PANEL - TYP.WINDOW SILL - SOLUTION() ELEVATION NTS DRAWING NAME: AW-FP-32 ARCHITECTURAL WALLS FABRIC PANEL WINDOW SILL - SOLUTION () DRAWING NO. 32

39 WINDOW MULLION WINDOW SILL PAINTED WALL CHANNEL BOTTOM & TOP /2" Wide ZIPPER 3" FABRIC PANEL FABRIC PANEL 33a FABRIC PANEL - TYP.WINDOW SILL- SOLUTION () PLAN NTS DRAWING NAME: AW-SP-33a ARCHITECTURAL WALLS FABRIC PANEL TYP.WINDOW SILL-SOLUTION(2) DRAWING NO. 33a

40 WINDOW SILL BULKHEAD PAINTED CEILING CHANNEL PAINTED WALL CHANNEL FABRIC FILLER PANEL WINDOW MULLION /2" Wide ZIPPER FABRIC PANEL PAINTED WALL CHANNEL 4" COVE BASE 33 FABRIC PANEL - TYP.WINDOW SILL- SOLUTION (2) ELEVATION NTS DRAWING NAME: AW-FP-33 ARCHITECTURAL WALLS FABRIC PANEL WINDOW SILL - SOLUTION (2) DRAWING NO. 33

41 ARCHITECTURAL WALL SECTION DEMOUNTABLE PARTITIONS PART GENERAL. RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 0 Specification Sections, apply to this Section..2 SUMMARY A. Section Includes. Non-progressive, moveable and reconfigurable system of unitized panels, from a single manufacturer. 2. Trim, Sealants, Hardware and Accessories..3 RELATED SECTIONS A. Section Substitution Procedures B. Section Wood Doors C. Section Door Hardware D. Section Glass and Glazing E. Section Ceilings F. Section Carpeting G. Section Power System H. Section Communication System.4 REFERENCES A. American National Standards Institute (ANSI). ANSI BIFMA X , Section 6.2 Panel System Strength Test Static Function Load MOVEABLE WALLS

42 ARCHITECTURAL WALL 2. ANSI BIFMA X , Section 6.3 Panel System Strength Test Static Proof Load B. American Society of Testing and Materials International (ASTM). ASTM C036, Standard Specification for Flat Glass 2. ASTM E72, Standard Test Methods of Conducting Strength Tests of Panels for Building Construction 3. ASTM E84, Standard Test Method for Surface Burning Characteristics of Building Materials 4. ASTM E90, Standard Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements 5. ASTM E43, Classification for Rating Sound Insulation C. National Fire Protection Association (NFPA) 70. National Electrical Code, 2008 Edition.5 PERFORMANCE REQUIREMENTS A. Acoustic Performance. Solid panels, when tested in accordance with ASTM E90, shall achieve the following acoustic performance ratings in accordance with ASTM E43, without site alteration: a. Solid panels: Minimum STC Glass panel acoustic performance: Per rating of specified glass type and thickness. 3. Provide butt hinged doors where acoustic performance of the wall system is paramount. 4. Provide sliding doors where indicated. B. Surface Burning Performance. Panels tested in accordance with ASTM E84 shall have: a. Flame Spread Index 25 or less b. Smoke Developed Index 450 or less C. Structural Performance. Provide demountable partitions capable of withstanding the effects of gravity loads and the following loads and stresses within limits under conditions indicated: a. Load-Bearing Capacity: Not less than 300lbs (36kg) concentrated proof load when tested according to BIFMA x5.6, Section MOVEABLE WALLS

43 ARCHITECTURAL WALL b. Transverse-Load Capacity: Lateral deflection of not more than /240 of the overall span when tested under a uniformly distributed load of 5 lb/sq ft (24.4 kg/sq m) according to ASTM E72. D. Electrical and Communications. Assembled panels shall be UL Classified to comply with NFPA 70 National Electric Code 2008 Edition. 2. Modular Wiring System Components shall be UL Listed to comply with NFPA 70, National Electric Code, Article 604 Manufactured Wiring Systems. E. Indoor Air Quality Performance. Demountable partition system shall carry Greenguard Indoor Air Quality Certification.6 DESIGN REQUIREMENTS A. The demountable partition system (the system) shall be rectilinear in design and expression with crisp corners and well defined horizontal and vertical elements. B. The system shall be 3 thick maximum, and designed and sized in horizontal and vertical modules to accommodate the partition layout shown on floor plans and sections, and to approval of Client representative.. Panel heights shall be available in /6 increments from a minimum of 84 to maximum of 44 as required. Actual floor to ceiling heights to be determined as per site dimensions. 2. Solid panel widths shall be available in /6 increments from a minimum of 6 to maximum of 48 for solid, combination and clerestory panels, and 60 for glass panels. C. Mineral Fiber board, gypsum board, medium density fiber board (MDF), glass and aluminum framed panels shall be constructed of materials acceptable for use in noncombustible construction. Fabric and wall covering finishes shall exhibit Class or Class A Surface Burning Performance. D. Provide wall systems with the following panel-to-panel connection options. Continuous, recessed slim-line connector, /2 wide, color from manufacturer s standard. E. The system shall be non-progressive, allowing for removal and re-installation of panels, including door frames, at any position, without disturbing adjacent panels. F. Each unitized panel shall be able to be removed, relocated and re-installed in different layouts, with all parts reusable. Scribing and fitting of panels on site to individual locations is not acceptable MOVEABLE WALLS

44 ARCHITECTURAL WALL G. The system shall provide a vertical adjustment of not less than +/-.00 or 2.00 in overall height to accommodate floor and ceiling irregularities. H. The panel/floor interface shall use a panel integrated floor track, with a 4 high base trim, mounted to the panel track with a flush surface on both sides. Trim shall be extruded ABS. I. The panel/ceiling interface shall be a 2-3/4 ceiling channel trim panel. Trim shall be factory painted extruded aluminum. J. The system shall include a freestanding option that does not require a connection or attachment to the ceiling. K. The system must be erected and removed in a manner to prevent damage to adjacent building surfaces and elements, including floors, walls, ceilings, columns and window mullions. All wall system connectors to fixed-in-place building components shall be non-marking, removable and reusable. L. The system shall be capable of extending in multiple directions using 2-way, 3-way, 4- way and variable angle corner posts. M. Door types. Butt hinged, [single][double], in [solid wood][aluminum framed glass], with flush aluminum factory painted frames. 2. Sliding, [single][double], in [solid wood][aluminum framed glass], with [metal][wood] frames. N. All door frames shall utilize standard panel connection methods and be reversible in field without additional modifications or materials. O. Components shall be free of distortion and uniform in dimension, construction and appearance. P. Solid panels shall be capable of providing integrated, factory installed modular power and voice/data distribution utilizing flex conduit or EMT for ease of panel reconfiguration..7 SUSTAINABILITY CRITERIA A. Total recycled content shall be greater than 5% combining both post-consumer and pre-consumer recycled content. B. All packaging materials shall be readily recyclable. C. Fiberglass insulation materials shall be formaldehyde-free and have a minimum of 25% recycled content. D. Product shall be Greenguard certified as a low emitting product MOVEABLE WALLS

45 ARCHITECTURAL WALL.8 SUBMITTALS A. Product Data: For each type of product indicated. B. Shop Drawings: Plans, sections, elevations, details and attachments to other work.. Indicate materials, methods of construction, attachment or anchorage details, erection diagrams of pre-assembled components, connections, explanatory notes and other information necessary for completion of work. Cross reference to design drawings and specifications. 2. Indicate wall layout, including doors and hardware, elevations, opening locations, special panels and conditions at adjacent construction. 3. Do not commence manufacture or order materials before shop drawings are reviewed and accepted by professional of record. C. Samples: Submit samples of each required finish and color. Prepare samples on same materials which will be used in partition assemblies.. Finish Samples a. For initial selection: For units with factory-applied color finishes. b. For verification: For each type of exposed finish and trim required. D. Product test reports from approved independent testing laboratory, certifying compliance with STC Rating, Surface Burning Rating, Structural Performance and Indoor Air Quality (Greenguard) Performance requirements..9 LEED SUBMITTALS A. Submit product data for the following credits in accordance to LEED 2009 for Commercial Interiors (CI):. Materials and Resources (MR) a. Credit MR 2 Construction Waste Management b. Credit MR 3.2 Materials Reuse Furniture and Furnishings c. Credit MR 4 Recycled Content d. Credit MR 5 Regional Materials 2. Indoor Environmental Quality (IEQ) a. Credit IEQ 3.2 Construction IAQ Management Plan, Before Occupancy b. Credit IEQ 8. Daylight and Views Daylight c. Credit IEQ 8.2 Daylight and Views Views 3. Innovation & Design Process (ID) a. Credit IDP Innovation in Design MOVEABLE WALLS

46 ARCHITECTURAL WALL.0 QUALITY ASSURANCE A. Manufacturer Qualifications. All primary products specified in this Section shall be supplied by a single manufacturer with a minimum of ten (0) years experience. B. Installer Qualifications: All products listed in this section shall to be installed by a single installer with a minimum of two (2) years documented experience in installing products of the same type and scope as specified, and must be approved by the manufacturer.. DELIVERY, STORAGE, AND HANDLING A. Deliver the demountable partition system components cartoned or crated to provide protection during transit and job storage. B. Inspect the demountable partition system components upon delivery for damage. Minor damages may be repaired, provided finish items are equal to new work and acceptable to Architect. Remove and replace damaged items as directed. C. Keep stored material covered and protected from damage..2 PROJECT CONDITIONS A. Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer for optimum results. Do not install the demountable partition system components under environmental conditions outside manufacturer's absolute limits. B. Environmental Limitations: Do not deliver or install the system components until building is enclosed and finishing operations, including ceiling and floor covering installation and painting, are completed. C. Field measurements: Indicate all site dimensions including ceiling heights and hold-to dimensions on shop drawings. D. Coordination of work: Coordinate layout and installation of the system components with other units of work. Installation of ceilings, floor coverings, lighting fixtures, HVAC equipment and fire suppression systems should be complete before the system components are installed..3 WARRANTY A. Submit, for Owner s acceptance, manufacturer s standard limited warranty document executed by authorized company official MOVEABLE WALLS

47 ARCHITECTURAL WALL. Warranty period: Ten (0) years from date of substantial completion..4 ATTIC STOCK A. Furnish items in original packaging clearly labeled with part number and description. Store in location designated by the Owner. B. Provide additional demountable partition system components to match installed materials. PART 2 PRODUCTS 2. MANUFACTURERS A. Acceptable Manufacturer: Nello Wall Systems, Inc Santa Barbara Court, Elkridge, MD Tel: Web: B. Substitutions: Not permitted. 2.2 PRODUCT A. Basis of Design: Provide Architectural Wall by Nello Wall Systems, Inc., or comparable product by one of the following:. [As determined by Architect] MATERIALS A. Panel Frames. Aluminum extrusions. 2. Formed 6 gauge steel hat sections. B. Insulation: Urea-formaldehyde free batt insulation, factory installed in all solid panels. C. Panel Faces. Wall covering-faced mineral fiber board: Class or Class A Surface Burning Performance. 2. Wood Composite Panels: Factory finished wood composite available with wood veneer, dry erase and painted finishes to manufacturer's standard. D. Doors and Hardware MOVEABLE WALLS

48 ARCHITECTURAL WALL. Provide doors in accordance with Section 0846, Flush Wood Doors. 2. Provide hardware in accordance with Section 08700, Door Hardware. 3. Provide woodwork in accordance with AWI, Architectural Woodwork Standards, Custom Grade. E. Glass and glazing materials. Provide glass and glazing in accordance with Section , Glazing. 2. Glazing sections: Resilient ABS, extruded glazing section to suit glazing channel retaining slot, to partition system manufacturer s standard, gaskets for setting glass. F. Trim. Ceiling: Factory painted aluminum extrusion 2. Base: Snap on 4 high extruded ABS 2.4 UNITIZED PANEL TYPES A. Solid Panels. Cladding a. Fabric faced, fully tackable, mineral fiber board b. Wood composite with wood veneer c. Wood composite with dry erase finish. d. Wood composite with factory painted finish 2. Frame a. Formed 6 gauge steel hat section 3. Acoustical insulation core: Urea-formaldehyde free batt insulation. B. Glazed Panels. Frame a. Extruded aluminum frame; minimum 0.06 thick, stile and frame with corner brackets, installed for full frame rigidity. 2. Glazing a. Monolithic: /4 thick glass panel, [tempered][laminated], ceiling height, fit in frame with glazing gaskets. b. Width of vertical mullions and horizontal muntins: [2 /2 ][ /4 ] MOVEABLE WALLS

49 ARCHITECTURAL WALL C. Combination Panels (including clerestory panels): Full height, [extruded aluminum][formed steel hat section] frame, with combinations of solid panel faces and glazed segments, as per approved elevations. D. Cut-able Panels: Solid panels with the inclusion of extended panel faces on one vertical edge providing cut-able surfaces to fit to irregularities in fixed-in-place construction (i.e. sills, columns, bulkheads) where required. E. Door panels. Door frames: Factory painted extruded aluminum, ceiling height, to accommodate and support [-3/4 thick, solid core wood doors][aluminum door with /4 [tempered][laminated] glass panel]with fixe. a. Prepare for hardware specified in Section 0870, Door Hardware. 2. Provide door frames with integrated glazed transom; dimensions as per approved elevations. 2.5 FABRICATION A. Fabricate the demountable partition system off-site in a controlled factory environment and deliver panels fully finished to site for installation with no additional assembly, construction or finishing required. 2.6 CONNECTION METHODS A. Demountable partition system to ceiling: Extruded aluminum channel/trim, attached to ceiling grid using non-marking clip. Ceiling channel/trim shall factory painted 2-3/4 deep and fit flush to the panel face. B. Demountable partition system to floor: Panel integrated extruded aluminum channel/track assembly, designed to grip and hold to carpet flooring without damage to floor surface. Threaded adjustable leveling legs with leveler saddles set into floor channel. Base assembly shall provide support for continuous mounting of 4 base trim on both panel faces. C. Demountable partition system to fixed-in-place construction: Extruded aluminum wall start channel affixed to permanent building components, lined with closed cell neoprene seals. D. Panel to panel, door frame or post connector. Continuous, extruded plastic slim-line connector applied to aluminum frame providing a /2 black reveal, recessed /4 from panel face and ensuring integrity of sound and light seal. E. For all exposed ends and corners, provide one piece aluminum extrusion to match panel finish, attached to end panel with standard panel-to-panel connector MOVEABLE WALLS

50 ARCHITECTURAL WALL 2.7 FINISHES A. Aluminum surfaces: Factory painted to manufacturer s standard range. B. Wood Surfaces: [Wood veneer][laminate] to manufacturer s standard and AWS Custom Grade. C. Panel faces containing MDF shall utilize fire rated material with no added urea formaldehyde. D. Mineral fiber board Wall Covering: Fabric or environmental wall covering. Color and pattern as selected by Architect from manufacturer s standard range. PART 3 EXECUTION 3. INSTALLATION A. Install the demountable partition system under manufacturer s approved, direct supervision to ensure wall performance and compatibility with design and specification intent. B. Erect the demountable partition system rigid, level, plumb and aligned. Install continuous light and sound seals at connection to floors, ceilings, fixed walls and abutting surfaces. C. Coordinate the demountable partition system installation with work of other trades which are affected. Avoid damage to installed work. D. Repair damaged or defaced work or replace with new work, as acceptable to Architect. Completely refinish defaced partition components with factory finished materials, or replace defaced components. E. Install doors and hardware as specified in Sections 0846 and Adjust hardware and doors and leave in proper operating condition. F. Acoustical Gaskets and Sealant: Seal cut-outs in panels, penetrations through partitions, and intersections with adjacent construction. Use gaskets where practical; use sealant at other locations and at fire rated partitions. 3.2 PROTECTION A. Protect installed demountable partition system components until completion of project. B. Touch-up, repair or replace damaged demountable partition system components before Substantial Completion. END OF SECTION MOVEABLE WALLS