16 GAGE, CONTINUOUS STAINLESS STEEL RESTRAINT METAL TO SUPPORT CUT TILE AT TERRACE EDGES. 24" x 24" PORCELAIN PAVERS WITH EDGE RESTRAINTS 1/2" MAX

Size: px
Start display at page:

Download "16 GAGE, CONTINUOUS STAINLESS STEEL RESTRAINT METAL TO SUPPORT CUT TILE AT TERRACE EDGES. 24" x 24" PORCELAIN PAVERS WITH EDGE RESTRAINTS 1/2" MAX"

Transcription

1

2

3 D.

4

5 CONTINUOUS SEALANT JOINT EACH SIDE OF GLASS CONTINUOUS GALVANIZED STEEL ANGLE 3 x 2 x 3/8". CUT SECTIONS TO MATCH THE GUARDRAIL CHANNEL LENGTHS ABOVE EXISTING LIMESTONE COPING EXISTING THRU- WALL FLASHING EXISTING ROOFING MEMBRANE EXTENDED OVER THE TOP OF THE WALL CR LAURENCE GRS WET GLAZING ALUMINUM CHANNEL. ANCHOR TO STEEL BELOW AT 2" O.C. INSTALL FC GRID ADHESIVE UNDER STEEL PLATE EXISTING 6" METAL STUD WALL CONSTRUCTION INSIDE RADIUS OF STONE COPING = 02' - 3 3/8" FIELD VERIFY 8" /4" 3" +/- ' - " +/- 7" FIELD VERIFY /2" STAINLESS STEEL, CONTINUOUS U- CHANNEL RAILING CAP WITH #4 FINISH- WELD AND GRIND JOINTS TYPICAL CONTINUOUS TEMPERED GLASS GUARDRAIL WITH POLISHED EDGES. PROVIDE " MAXIMUM GAPS BETWEEN PANELS- WET GLAZE GLASS TYPICAL. ASSUME (8) 4'-0" +/- GLAZING PANELS AT RADIUS CONTINUOUS 8 GAGE STAINLESS STEEL ELL FLASHING- PROVIDE HEMMED EDGES TYPICAL EACH SIDE OF GLASS. SET FLASHING IN GLAZING STOPS AND WATERPROOF MASTIC NEW RADIUSED GRAY LIMESTONE COPING- MATCH THE JOINT PATTERN OF THE EXISTING STONE COPINGS PC GALVANIZED STEEL ANGLE 3" x 3" x 3/8" x 6" WELDED TO EACH BENT PLATE AND CONTINUOUS ANGLE ABOVE GALVANIZED STEEL BENT PLATE 4" x 9-/2" x 8" WIDE AT 20" O.C. MAX. INSTALL BITUTHANE MEMBRANE BETWEEN THE PLATE AND ROOFING MEMBRANE. LAG EACH PLATE TO THE PARAPET USING FOUR /2" LAG BOLTS. NEW CONTINUOUS 2x6 BLOCKING AT PARAPET. WRAP WITH NEW PVC ROOFING MEMBRANE DELEGATED GUARDRAIL DESIGN: GUARDRAIL CONTRACTOR TO CONFIRM THE ILLUSTRATED ANCHORAGE TO MEET OR EXCEED THE MANUFACTURER'S MINIMUM DESIGN REQUIREMENTS UNDER THE INDIANA BUILDING CODE. THE CONTRACTOR IS TO MODIFY THE DESIGN AS REQUIRED BY THE MANUFACTURER. 3 8" 6" 3' - 6" ' - 6" Guardrail Detail /2" = '-0" INSTALL LIQUID FLASHING TO POST AND FASTENERS AT TOP SIDE OF PLATE INSTALL MULTI PURPOSE TAPE BEHIND PLATE AT FASTENER LOCATION EXISTING WALL HYDRANT 20C Balcony Level 8' - 0" 2 24" x 24" PORCELAIN PAVERS WITH EDGE RESTRAINTS 'BUILT IN PLACE' GREEN ROOF SYSTEM COMPLETE WITH SOIL AND PLANTINGS ADJUSTABLE HEIGHT PEDESTAL BASES- INSTALL PROTECTION MEMBRANE AS REQUIRE CONTINUOUS EXTRUDED POLYSTYRENE AS REQUIRED FOR SHIMMING PLANT TRAYS- INSTALL PROTECTION MEMBRANE AS REQUIRED EXISTING PVC MEMBRANE ROOF COMPLETE WITH RECOVERY BOARD AND TAPERED INSULATION TERRACE 20C 095 SF NEW SARNAFIL G40 PVC ROOF MEMBRANE, HEAT WELD AND ADHERE AT ALL PERIMETER EDGES. PROVIDE LOOSE LAID FIELD. MEMBRANE ONLY IS PROVIDED BY OWNER. ALL OTHER ROOFING MATERIALS BY THE ROOFER. A 6 GAGE, CONTINUOUS STAINLESS STEEL RESTRAINT METAL TO SUPPORT CUT TILE AT TERRACE EDGES EXISTING WALL HYDRANT 20D 24" x 24" PORCELAIN PAVERS WITH EDGE RESTRAINTS 2 HH JJ /2" MAX DD Balcony Level 8' - 0" Flashing Detail /2" = '-0" EXISTING MASONRY VENEER EXISTING STAINLESS STEEL FLASHING RECEIVER NEW FLAT METAL COUNTER FLASHING EXISTING TERMINATION BAR FOR ROOFING MEMBRANE ADJUSTABLE HEIGHT PEDESTAL BASES, SET TIGHT TO WALL NEW SARNAFIL G40 PVC ROOF MEMBRANE, HEAT WELD AND ADHERE AT ALL PERIMETER EDGES. PROVIDE LOOSE LAID FIELD. MEMBRANE ONLY IS PROVIDED BY OWNER. ALL OTHER ROOFING MATERIALS BY THE ROOFER. EXISTING PVC MEMBRANE ROOF COMPLETE WITH RECOVERY BOARD AND TAPERED INSULATION THESE NOTES APPLY TO ALL CONTRACTORS AND/ OR SUBCONTRACTORS THAT WORK ON THIS PROJECT.. ALL WORK OVER THE EXISTING ROOFING MEMBRANE MUST BE REVIEWED AND APPROVED BY SIKA/ SARNAFIL PRIOR TO THE INSTALLATION OF NEW MATERIALS THE INSTALLATION OF PROTECTION MEMBRANES, MASTICS AND OTHER ROOFING COMPONENTS MUST BE SOURCED AND INSTALLED BY BLACKMORE AND BUCKNER WHO HOLDS THE WARRANTY AS THE INSTALLING ROOFING CONTRACTOR. ALL WORK MUST BE INSPECTED AND CERTIFIED BY THE ROOFING MANUFACTURER TO MAINTAIN THE EXISTING ROOF WARRANTIES. 2. OWNER WILL REMOVE ALL FURNISHINGS, LOOSE EQUIPMENT, SUPPLIES, ETC. PRIOR TO CONSTRUCTION COMMENCING. 3. GENERAL CONTRACTOR AND THEIR SUBCONTRACTORS SHALL BE RESPONSIBLE FOR VISITING THE CONSTRUCTION SITE TO BECOME FAMILIAR WITH ALL EXISTING CONDITIONS WHICH AFFECT THAT SPECIFIC PORTION OF THEIR WORK. ANY CONFLICTS OR APPARENT DEFICIENCIES MUST BE SUBMITTED TO THE ARCHITECT IN WRITING PRIOR TO BIDDING. 4. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR INFORMING IN WRITING THE OWNER ON A WEEKLY BASIS OF THE CONSTRUCTION SCHEDULE FOR THE APPROACHING TWO WEEKS CONSTRUCTION ACTIVITY. ANY STORAGE OF MATERIALS, ACCESS OR EGRESS PROBLEMS, TRAFFIC FLOW OR NORMAL OWNER OPERATIONS WHICH ARE TO BE AFFECTED MUST BE PROTECTED AND/OR AGREED UPON BY THE OWNER. ALL COSTS SHALL BE INCURRED BY THE GENERAL CONTRACTOR. 5. THE GENERAL CONTRACTOR SHALL PROVIDE ALL NECESSARY WOOD BLOCKING FOR ALL TRADES. THIS BLOCKING SHALL BE FIRE RETARDANT. 6. ITEMS SHOWN IN LIGHTER PEN WEIGHT ARE EXISTING TO REMAIN. 7. ALL CONSTRUCTION AREAS, REMOVAL TRAFFIC PATTERN AREAS AND ASSOCIATED WORK AREAS SHALL BE KEPT CLEAN OF DEBRIS BY THE CONTRACTORS DAILY. 8. PROTECT FROM DEMOLITION AND RECONSTRUCTION DEBRIS, ALL "EXISTING TO REMAIN" FIXTURES AND EQUIPMENT REQUIRED TO REMAIN IN PLACE DURING CONSTRUCTION. 9. PORTIONS OF THE BUILDING SHALL BE OCCUPIED DURING CONSTRUCTION. THE GENERAL CONTRACTOR SHALL FOLLOW THE FOLLOWING LIFE SAFETY ISSUES. FAILURE TO LIST ALL LIFE SAFETY ISSUES DOES NOT RELIEVE THE CONTRACTORS FROM COMPLYING WITH FEDERAL, STATE AND LOCAL CODES, THE CONTRACTUAL AGREEMENT BETWEEN THE CONTRACTOR AND OWNER, AND OTHER GOVERNING BODIES WHICH HAVE JURISDICTION ON THIS PROJECT. THE FOLLOWING ARE INTERIM LIFE SAFETY CODE ISSUES WHICH ARE SPECIFIC TO THIS PROJECT AND MUST BE ADDRESSED: a. INSURE ALL EXITS PROVIDE FREE AND UNOBSTRUCTED EGRESS. STAFF AND PERSONNEL SHALL RECEIVE TRAINING AND WRITTEN NOTIFICATION IF ALTERNATIVE EXITS MUST BE DESIGNATED. b. INSURE FREE AND UNOBSTRUCTED ACCESS TO EMERGENCY DEPARTMENTS OR SERVICES FOR EMERGENCY FORCES. COORDINATE WITH OWNER AND ARCHITECT. c. INSURE FIRE ALARM, DETECTION AND SUPPRESSION SYSTEMS ARE NOT IMPAIRED. A TEMPORARY, BUT EQUIVALENT, SYSTEM SHALL BE PROVIDED, INSTALLED AND TESTED PRIOR TO ANY EXISTING FIRE SYSTEM BEING IMPAIRED. d. INSURE TEMPORARY CONSTRUCTION PARTITIONS ARE SMOKE TIGHT AND BUILT OF NON COMBUSTIBLE MATERIALS. THESE PARTITIONS SHALL BE COORDINATED WITH THE OWNER AND ARCHITECT. e. SMOKING IS PROHIBITED ON CAMPUS. f. DEVELOP AND ENFORCE STORAGE, HOUSEKEEPING AND DEBRIS REMOVAL PROCEDURES THAT REDUCE THE FLAMMABLE AND COMBUSTIBLE FIRE LOAD TO THE LOWEST LEVEL NECESSARY FOR DAILY OPERATIONS. g. IOSHA REQUIRES MATERIAL SAFETY DATA SHEETS (MSDS) FOR ALL MATERIALS BEING USED OR STORED ON THIS PROJECT BE MADE AVAILABLE TO ALL WORKERS ON THIS JOBSITE. AS WORK BEGINS, COPIES MUST BE PROVIDED TO THE OWNER'S DIRECTOR OF SECURITY, IMMEDIATELY. h. SECURE ALL TOOLS AND CONSTRUCTION MATERIALS DURING BREAKS AND NON-CONSTRUCTION HOURS. i. WHEN ASSEMBLY EVENTS ARE SCHEDULED THERE WILL BE NO CONSTRUCTION ACTIVITIES SCHEDULED DURING THE REQUIRED FIRE DEPARTMENT INSPECTIONS AND DURING THE EVENT ITSELF. THE CONTRACTOR WILL MAKE ANY CORRECTIONS DEEMED NECESSARY BY THE FIRE DEPARTMENT TO PROVIDE SAFE AND CLEAR EGRESS THROUGH THE CONSTRUCTION AREAS. DENOTES WORK FABRICATED AND INSTALLED BY GUARDRAIL CONTRACTOR UNDER CONTRACT DIRECT WITH BALL STATE UNIVERSITY (REQUEST FOR QUOTE). ALL OTHER WORK INDICATED IS PART OF THE PAVER AND GREEN ROOF PROJECT (PUBLIC WORKS BID). General Construction Notes MSKTD & Associates Architecture Engineering Interior Design 75 Magnavox Way Fort Wayne, IN CERTIFICATION Emens Auditorium Terrace Pavers and Green Roof BSU Project Number: AU PROJECT NO. GARY EDWARD REGISTERED AR STATE OF I I ND No. A N A VOI ROL ARCHI TECT 930 North Meridian Indianapolis, IN DATE Riverside Avenue, Muncie, IN REVISIONS DATE BY Addendum 05/08/8 RAD 5/9/208 0:0:26 AM ' - 5"+/- F.V. (8) 4' - 0" +/- PANELS AT RADIUS TYPICAL R5 R4 84' - 4" +/- FIELD VERIFY /8" = '-0" 89' - 0" R3 3 Balcony Level Plan R2 ' - 5" +/- F.V. A Specific Construction Notes PROVIDE 24" x 24" PORCELAIN PAVERS ON ADJUSTABLE PEDESTAL BASES. SET LEVEL WITH BALCONY FINISHED FLOOR. COORDINATE PERIMETER EDGE WITH ADJACENT GREEN ROOF SYSTEM. CONTAIN PERIMETER EDGE AS REQUIRED FOR WIND UPLIFT. PROVIDE 'BUILT IN PLACE' GREEN ROOF SYSTEM AS SPECIFIED WITH IRRIGATION SYSTEM. SET LEVEL WITH BALCONY FINISHED FLOOR. COORDINATE PERIMETER EDGE WITH ADJACENT ROOF PAVERS. BLOCK/ SHIM PLANT SYSTEM USING EXTRUDED POLYSTYRENE THAT IS SET ON THE ROOF MEMBRANE. PROVIDE AND INSTALL DRIP LINE IRRIGATION SYSTEM COMPLETE WITH AUTOMATED CONTROLLER AND DISTRIBUTION SYSTEM. CONNECT TO EXISTING HOSE BIB AND EXTERIOR OUTLET - CONTRACTOR IS REQUIRED TO MODIFY EXISTNG INSTALLATIONS AS REQUIRED TO MEET ALL CODES AND MANUFACTURER'S REQUIREMENTS. PROVIDE AND INSTALL AN LCN #4040 EXTERIOR SURFACE DOOR CLOSER COMPLETE WITH EXTERIOR ARMS AND ALL REQUIRED MOUNTING HARDWARE. MODIFY THE DOOR AS REQUIRED. WHERE THE INTERIOR CLOSER HAS BEEN REMOVED INSTALL MATCHING ALUMINUM PLUGS OR SCREWS TO FILL THE ABANDONED HOLES IN TEH WINDOW FRAME. OWNER TO INSTALL SIGNAGE INDICATING, "TERRACE MAXIMUM OCCUPANCY 49 PEOPLE". REMOVE THE EXISTING METAL COUNTER FLASHINGS FROM THE STAINLESS STEEL RECEIVER. INTALL NEW FLAT, MATCHING METAL FOR PEDESTAL BASE INSTALLATION. OWNER WILL PROVIDE TO THE ROOFING CONTRACTOR THE REQUIRED SARNAFIL G40 ROOFING MEMBRANE FOR OVERLAYING THE TERRACE AREA. ALL OTHER ROOFING ACCESSORIES, FLASHINGS, SEALANTS, MASTICS, PROTECTIVE SLIP SHEETS, ETC. ARE PROVIDED BY THE ROOFING CONTRACTOR. THE ROOFING CONTRACTOR IS RESPONSIBLE FOR PROVIDING A COMPLETE LOOSE-LAID ROOFING OVERLAY PRIOR TO THE INSTALLATION OF PAVERS AND GREEN ROOF. INSTALL NEW CONTINUOUS 2X6 WOOD BLOCKING TO THE TOP OF THE PARAPET AS ILLUSTRATED FOR COPING ANCHORING. WRAP ALL BLOCKING WITH NEW ADHERED MEMBRANE. SET DESCRIPTION Bid Documents SHEET TITLE Balcony Level Plan & Terrace Details SHEET NUMBER