1 YOUR PROCESSES ON SAFE FLOORING nora systems 1

2 2 nora systems Safety for your processes from the ground up Cleanroom suitability nora flooring systems were tested by Fraunhofer IPA, which certified their eligibility for GMP A as well as under ISO to Class 2. With their high resistance to biological contamination, chemicals and disinfectants, nora flooring is the ideal solution for cleanrooms. Cleanliness suitability In the context of suitability in the different application areas, we guide and support you with personalised consulting tailored to your project: The application relevant parameters of the process environment are coordinated with your project. The assessment of the influence of different process media and the disinfectants used complete the nora service offer. All-round safety with nora flooring systems Application Permanent elasticity to protect against falling objects Ergonomic for high walking and standing comfort Resistant even at high loads Discharge capability / ESD protection with 10 years warranty Hygiene: Easily disinfected Hygienic solutions for frames, pipes, drains Homogeneous and free of coating Maintenance: Quick refurbishment of stressed surfaces, depending on the process, even when operational (<1 day possible) Conversion of small areas to different processes possible Floor structure in the system: nora system blue Made in Germany Advantages: Extremely robust and impact resistant surface Modular installation allows maintenance even when operational Natural rubber as a homogeneous material makes extra coating redundant nora floorings are tested for media compatibility

3 Flexible solutions for a smooth operation nora systems 3 Your processes have changed? The container foot is no longer required? Would you like to refurbish highly stressed areas during operation? nora flooring system gives you flexible solutions. Adaptation to changed processes Changes or expansions to the production process usually also entail structural changes. Thanks to the modular installation possibility of nora floorings, surfaces can easily be adapted to the new processes. Refurbishment of surfaces Highly stressed surfaces can be refurbished without the effort of switching out the entire flooring. Hygienic connections of installations nora floorings can be applied in various ways to vertical installations or recesses. A variety of configurations are available for connections to frames, pipes, drains or other installations.

4 4 nora systems Comfort and safety for your employees A safe, comfortable work environment contributes significantly to the health and satisfaction of your employees. nora flooring systems made of natural rubber create a positive working environment through their compatibility, permanent elasticity and a large range of colours. Highest ergonomic comfort The permanently elastic material natural rubber offers high walking and standing comfort, making it easier on the back and joints. The body thus suffers much less fatigue than on hard floors even after prolonged standing. Low emissions for good indoor air nora floorings contain no plasticisers (phthalates) or halogens, which helps them contribute to healthy indoor air. This has been recognised with the award of the eco-label The Blue Angel (RAL-UZ 120 or 113) as well as all other major international environmental certificates.

5 Guaranteed system safety with nora system blue nora systems 5 This coordinated, sustainably oriented and certified total system combines low-emission nora natural rubber floors with low-emission nora flooring installation materials. In addition, selected technicians are specially trained for nora system blue. Because each individual system component guarantees the highest level of safety, the entirety of the system has also been certified by TÜV Rheinland. nora systems extends the warranty for nora system blue to seven years. All system components have been tested in combination and are awarded with the eco-label The Blue Angel (RAL-UZ 120 or 113). The system configuration: Primer 2 Levelling compound 3 Adhesive 4 norament Further information can be found in our nora system blue brochure and on

6 6 nora systems nora fl oorings for GMP and ISO Particle emission characteristics: to ISO Class 2 / GMP Class A Outgassing characteristics: to ISO AMC Class 6.3 Body voltage generation / walk test: < 10 V High resistance to biological contamination High resistance to disinfectants and chemicals High walking and standing comfort thanks to permanent elasticity Excellent fire protection properties Extremely leakproof and closed surface without coatings Free of PVCs, halogens (e.g. chlorine) and plasticisers (phthalates), thus low emission Certifi ed environmental sustainability Guaranteed ESD protection: 10 year warranty on the electrostatic properties An extensive accessory collection for hygienic connections Certified: DIN EN ISO 14001, DIN EN ISO 50001

7 nora systems 7 Parameter Testing standard Requirements Average test values of the current production noraplan astro ec noraplan mega ed noraplan signa ed* norament 928 grano ed CE compliance EN Manufacturer: nora systems GmbH, D Weinheim Dynamic coefficient of friction EN DS Fulfilled Electrical characteristics EN 1081 ed = 10 9 Ohm - Fulfilled ec = 10 6 Ohm Fulfilled - - Fire Class EN Unbonded C fl -s1 C fl -s1, bonded Fire Class EN Bonded on mineral supporting base Required material properties according to ISO and EC-GMP guidelines Smooth, leakproof, nonporous surface High abrasion resistance or low particle emissions characteristic Biological Resistance Microbial metabolic potential Outgassing Outgassing characteristics (TVOC at 23 C / 90 C) VDI ISO 846 ISO 846, Method A ISO 846, Method C VDI Air Purity Class according to ISO GMP Class according to EU-GMP Annex 1, in operation Overall result Biological resistance to fungi Biological resistance to bacteria ISO AMC Class according to ISO C fl -s1 B fl -s1 B fl -s1 Extremely leakproof and closed surface without coatings A A A 1/very good 1/very good 1/very good 1/very good ISO -5.8 ISO -6.3 ISO -6.2 Amine 6.3 x 10E-6 g/m²s Not detectable 3.4 x 10E-5 g/m²s Organophosphate Not detectable Not detectable Not detectable Siloxane Not detectable Not detectable Not detectable Phthalates Not detectable Not detectable Not detectable nora flooring systems are resistant to surface disinfectants from the list of the Cleaning and disinfection properties Disinfectants Commission of the Association for Applied Hygiene (VAH) and the Robert Koch Institute (RKI) and are to be safely treated with a correctly performed wipe disinfection. 4) Resistance to chemicals and corrosion EN 423 Resistant depending on concentration and exposure time 1) Slip resistance DIN R9 R9 R9 Toxicity of the fumes DIN Escaping carbonisation gases are toxicologically harmless. Electrical measurements 2) Earth resistance DIN EN 1081 <10 6 Ω x 10 7 Ω x 10 7 Ω Resistance to EPA earth Earth resistance or resistance to EPA earth Body voltage generation Chargeability ESD STM 7.1 / IEC ESD STM 97.1 / IEC ESD STM 97.2 / IEC In the installed state at 23 C (± 2 C) and 25 % r.f. In the installed state at 23 C (± 2 C) and <25 % r.h. and a suitable system configuration For the system ground flooring/conductive footwear (R <5 x 10 6 Ω) in the installed state at 23 C (± 2 C) and 25 % r.h. Tested with defined ESD footwear at 21 C and 20 % r.h. <10 6 Ω x 10 7 Ω x 10 7 Ω <10 6 Ω Ω 3) Ω 3) <3,5 x 10 7 Ω 3,5 x 10 7 Ω 3,5 x 10 7 Ω Insulation resistance VDE x 10 4 Ω 5 x 10 4 Ω * noraplan mega ed has been tested. Due to identical manufacturing processes and ingredients, results should be identical to those of noraplan signa ed. 1) In the case of increased exposure to oils, greases, acids, alkalis and other aggressive chemicals, consultation with us is required. 2) The stated values apply to the installation in accordance with our recommendations for electrostatic dissipative or electrostatic conductive nora flooring systems while taking into account the information given by the adhesive manufacturers. According to EN , the adhesive used must permanently maintain a resistance of R <3 x 10 5 Ω. 3) If prolonged extremely low humidity values (<25 % r.h.) are expected, please consult with nora systems GmbH. 4) Disinfectability confirmed by the Heidelberg University Hospital, Department of Infectious Diseases (Prof. Dr. med. U. Frank) or by the Institute for Medical Microbiology and Hospital Hygiene at the University of Marburg (Prof. Dr. R. Mutters). Test certificates can be requested if necessary. We reserve the right to alter production-related colour variations as well as technical changes which serve to improve the products. <10 V

8 nora systems Shanghai Co. Ltd. 10 A/B, Long Life Building 1566 Yan an Road West Shanghai, PR China Phone: Fax: nora systems GmbH (DMCC Branch) Office 3504, HDS Business Center Cluster M JLT Dubai, UAE Phone: +971 (4) Mobile: +971 (56) Fax: +971 (4) rakesh.maliakal@nora.com nora flooring systems UK Ltd. 4 5 Allerton Road Rugby CV23 0PA, Great Britain Direct Dial Numbers: (01788) Fax: (01788) info-uk@nora.com nora systems GmbH Höhnerweg Weinheim, Germany Phone: +49 (0) info@nora.com /2017