BATH HOUSE STRUCTURE FOR: HOLLAND PARK

Size: px
Start display at page:

Download "BATH HOUSE STRUCTURE FOR: HOLLAND PARK"

Transcription

1 N COVER SHEET DJS ajp

2 GENERAL NOTES ` DJS AJP

3 FOUNDATION, FLOOR ROOF FRAMING PLANS DJS AJP

4 6 A-2 5 A-2 6 A-2 ELEVATIONS ` DJS AJP

5 WALL SECTIONS ` DJS AJP

6 1 A-4 2 A-4 SCHEDULES & DETAILS DJS AJP

7 CC gmp ELEC LTG & PWR PLAN, LEGEND & PNL SCHEDULE AUXILIARY STRUCTURES FOR: SPLASH PARK RESTROOM DESIGN

8 PLUMBING SPECIFICATIONS GENERAL NOTES - PLUMBING GENERAL PROVISIONS 1.1 PROVIDE ALL LABOR, MATERIAL AND EQUIPMENT FOR A COMPLETE AND PROPERLY OPERATING PLUMBING SYSTEM. 1.2 CODES AND STANDARDS: ALL PLUMBING WORK SHALL BE IN STRICT COMPLIANCE WITH THE STANDARD PLUMBING CODE AND ALL LOCAL CODES HAVING JURISDICTION. 1.3 ALL PLUMBING WORK SHALL BE DONE IN A NEAT AND WORKMANLIKE MANNER. 1.4 CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS AND FEES, ETC., REQUIRED FOR THE EXECUTION OF THIS WORK. 1.5 CONTRACTOR SHALL COORDINATE HIS WORK WITH ALL OTHER TRADES BEFORE FABRICATION OR INSTALLATION. OFFSETS AND/OR TRANSITIONS REQUIRED SHALL BE PROVIDED WITHOUT ADDITIONAL COST. CONTRACTOR SHALL COORDINATE AND INSTALL HIS WORK IN A TIMELY MANNER TO PREVENT DELAYS IN THE CONSTRUCTION. 1.6 CONTRACTOR SHALL BE RESPONSIBLE TO REPAIR OR REPLACE DAMAGED EQUIPMENT AND/OR MATERIAL. 1.7 PROVIDE ALL MATERIALS REQUIRED TO PROPERLY SUPPORT ALL PIPING AND EQUIPMENT. PIPE HANGERS SHALL BE ADJUSTABLE TYPE AND BE SPACED IN ACCORDANCE WITH THE STANDARD PLUMBING CODE. PROVIDED PLASTIC COATED RING ON HANGERS FOR COPPER PIPING TO PROVIDE DIELECTRIC ISOLATION. 1.8 PROVIDE DIELECTRIC UNIONS OR FLANGES BETWEEN COPPER AND STEEL PIPING AND BETWEEN BRASSWARE AND STEEL. DO NOT USE STEEL AND COPPER PIPING IN THE SAME SYSTEM WITHOUT SUCH ISOLATION. 1.9 PROVIDE REDUCING FITTINGS (REDUCING BUSHINGS SHALL NOT BE USED) WHERE CHANGES IN PIPE SIZES OCCUR THIS CONTRACTOR SHALL SUPPLY AND INSTALL ALL SERVICES THROUGHOUT THE BUILDING AND MAKE CONNECTION TO SITE UTILITIES APPROXIMATELY 5'-0" OUTSIDE THE BUILDING. CONTRACTOR SHALL SUPPLY AND INSTALL FIXTURES, FITTINGS, VALVING AND TRIM AND MAKE READY FOR USE ALL FIXTURES, EQUIPMENT, ETC SEE ARCHITECTURAL DRAWINGS FOR FIXTURE LOCATIONS AND MOUNTING HEIGHTS BASIC MATERIALS AND METHODS 2.1 ABOVEGROUND WATER PIPE AND FITTINGS - SCHEDULE 40 CPVC W/SOLVENT WELDED FITTINGS. 2.2 PROVIDE UNIONS OR FLANGES IN ALL DOMESTIC WATER SERVICE LINES AT EACH PIECE OF EQUIPMENT, SPECIALTY VALVES OR AT OTHER LOCATIONS REQUIRED FOR READY DISCONNECT. 2.3 WATER HAMMER ARRESTORS SHALL BE INSTALLED AT THE LOCATIONS ON THE PLANS AND IN ACCORDANCE WITH PDI STANDARD WH-201. PRODUCTS SHALL BE EQUAL TO THOSE MANUFACTURED BY PRECISION PLUMBING PRODUCTS OR SIOUX CHIEF. 2.4 VALVES: PROVIDE VALVES TO ISOLATE EACH RISER, BRANCH LINE AND PIECE OF EQUIPMENT. 2.5 PROVIDE PRESSURE REDUCING VALVE AND AIR GAP CONNECTION AT DISHWASHER AS REQUIRED BY CODE AND ACCORDING TO MANUFACTURER. 2.6 PROVIDE INLINE WATER FILTER (UNLESS PROVIDED BY EQUIPMENT VENDOR) AT COFFEE MAKER AND ICE MAKER TO REMOVE MATERIALS, TASTE AND ODOR - "EVERPURE OR "SYSTEMS IV". 2.7 ABOVEGROUND SANITARY WASTE, SANITARY VENT AND STORM PIPING - SCHEDULE 40 PVC W/SOLVENT WELDED FITTINGS (EXCEPT IN RETURN PLENUMS). SERVICE WEIGHT CAST IRON WITH NO-HUB COUPLINGS - ("HUSKEY 4000" OR "CLAMPALL" ONLY) FOR HI-TEMP KITCHEN AREA DRAINAGE. 2.8 ABOVEGROUND SANITARY WASTE ARMS - SCHEDULE 40 PVC OR DWV COPPER. 2.9 INSTALL GRAVITY LINES SLOPED AT 1/8" PER FOOT FOR PIPE 3" AND LARGER AND 1/4" PER FOOT FOR PIPE SMALLER THAT 3". VERIFY INVERT ELEVATION WITH SITE PIPING PRIOR TO ANY PIPE BEING INSTALLED PLUMBING FIXTURES AND TRIM 3.1 ALL PLUMBING FIXTURES SHALL BE "FIRST QUALITY" AS DEFINED AND SET FORTH IN COMMERCIAL STANDARD CS77-28 AS PROMULGATED BY THE U.S. DEPARTMENT OF COMMERCE. 3.2 ALL FIXTURES ARE TO BE WHITE VITREOUS CHINA UNLESS OTHERWISE SPECIFICALLY NOTED. 3.3 FIXTURES AND FITTINGS PROPOSED SHALL BE FROM ONE MANUFACTURER AND OF SIMILAR CHARACTER IN ANY ROOM OR LOCATION. ESCUTCHEONS, HANDLES, ETC., ON THE DIFFERENT FIXTURES SHALL BE OF THE SAME DESIGN. 3.4 PROVIDE FIXTURE CARRIERS AS RECOMMENDED BY FIXTURE MANUFACTURER AND/OR CONSTRUCTION METHOD. PLUMBING SYSTEM WAS DESIGNED USING THE 2010 FBC. PLUMBING CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL NECESSARY FITTINGS AS REQUIRED BY ALL APPLICABLE CODES AND GOVERNING AUTHORITIES. PLUMBING CONTRACTOR SHALL VERIFY AND CORRECT AS REQUIRED TO MEET ALL CODES AND REGULATIONS ANY POSSIBLE DISCREPANCIES BETWEEN TYPE AND SIZE OF CONNECTION SPECIFIED IN PLUMBING FIXTURE SCHEDULE AND FIXTURES ACTUALLY INSTALLED ON THE SITE. ALL SANITARY PIPING 3" AND LARGER SHALL HAVE 1/8" MINIMUM PER FOOT SLOPE. ALL SANITARY PIPING 2 1/2" AND SMALLER SHALL HAVE A 1/4" MINIMUM PER FOOT SLOPE. PLUMBING CONTRACTOR SHALL COORDINATE ALL WORK WITH OTHER TRADES. PLUMBING CONTRACTOR SHALL FIELD VERIFY ALL GIVEN MEASUREMENTS PRIOR TO LAYING AND CONNECTING ALL SANITARY AND WASTE PIPING AND NOTIFY ARCHITECT OF ANY DISCREPANCIES. PLUMBING CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING FIRE RATING AND WEATHERPROOFING INTEGRITY OF ALL PIPING AND PENETRATIONS. ALL WATER SUPPLY AND SANITARY LINES SHALL BE RUN AS CLOSE TO PLANS AS POSSIBLE WITH NO CHANGES IN SIZES. PLUMBING CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL NECESSARY SUPPORTING DEVICES FOR ALL FIXTURES INCLUDED IN CONTRACT OR HEREIN SPECIFIED OR OTHERWISE. ALL PIPE AND FITTINGS SHALL BE DOMESTICALLY MANUFACTURED IF POSSIBLE (MADE IN USA) AND ALL SANITARY, STORM, CONDENSATE AND WATER SUPPLY LINES SHALL BE MARKED WITH THE SEAL OF APPROVAL OF THE NATIONAL SANITATION FOUNDATION. WHERE SANITARY SEWER LINES CROSS UNDERGROUND WATER SUPPLY LINES WITH LESS THAN 8" MINIMUM VERTICAL CLEARANCE, THE SANITARY SEWER SHALL BE CONSTRUCTED OF DUCTILE IRON PIPE (10' EACH SIDE OF WATER MAIN) OR THE WATER LINES SHOULD BE MODIFIED TO PROVIDE 8" MINIMUM CLEARANCE. ROUTE ALL PIPING CONCEALED ABOVE CEILINGS, WITHIN WALLS, OR IN CHASES EXCEPT AS SPECIFICALLY NOTED, OR IN MECHANICAL ROOMS. PROVIDE ACCESS PANELS TO ALL VALVES WITHIN CHASES OR ABOVE NON-ACCESSIBLE CEILINGS. REFER TO ARCHITECTURAL DRAWINGS FOR CEILING TYPES. PLUMBING CONTRACTOR SHALL VERIFY INVERT ELEVATIONS OF SEWERS TO WHICH NEW SEWER LINES ARE TO BE CONNECTED BEFORE INSTALLATION OF NEW SEWER LINE. PLUMBING CONTRACTOR SHALL INSTALL DIELECTRIC UNIONS AT CONNECTIONS OF DISSIMILAR METALS. ALL WATER PIPING INSTALLED IN EXTERIOR WALLS SHALL BE PLACED ON THE INTERIOR SIDE OF THE WALL, SO THAT WALL INSULATION CAN BE PLACED ON THE EXTERIOR SIDE OF THE PIPING. THE PLUMBING CONTRACTOR IS EXPECTED TO ORDER ALL MATERIALS IN SUFFICIENT TIME TO AVOID DELAYING THE COMPLETION OF THE PROJECT. DELAY IN DELIVERIES WILL NOT BE CONSIDERED A JUSTIFIABLE REASON FOR SUBMISSION OF SUBSTITUTE MATERIALS. DO NOT PENETRATE WALL FOOTINGS WITH PIPING, COORDINATE WITH GENERAL CONTRACTOR TO DROP OR BRIDGE FOOTINGS AS REQUIRED TO CLEAR PLUMBING SERVICES WHERE ABSOLUTELY NECESSARY. ALL PIPING PENETRATING A BEARING WALL OR FOOTING MUST BE SLEEVED AND LOCATION APPROVED BY STRUCTURAL ENGINEER. INSTALL WATER HAMMER SHOCK ARRESTORS AT EACH FIXTURE OR BATTERY OF FIXTURES WHERE REQUIRED. ARRESTORS SHALL BE FACTORY FABRICATED. INSTALL ARRESTORS AND SIZE PER PLUMBING AND DRAINAGE INSTITUTE STANDARD PDI WH 201. ACCEPTABLE MANUFACTURERS ZURN, JOSAM, JAY R. SMITH. PLUMBING CONTRACTOR SHALL VISIT AND CAREFULLY EXAMINE THOSE PORTIONS OF THE SITE AFFECTED BY THIS WORK BEFORE SUBMITTING PROPOSALS SO AS TO BECOME FAMILIAR WITH EXISTING CONDITIONS AND DIFFICULTIES THAT WILL AFFECT EXECUTION OF THE WORK. SUBMISSION OF A PROPOSAL WILL INDICATE THAT SUCH EXAMINATION BY THE CONTRACTOR HAS BEEN MADE. LATER CLAIMS FOR LABOR, EQUIPMENT OR MATERIALS REQUIRED BECAUSE OF DIFFICULTIES ENCOUNTERED WILL NOT BE RECOGNIZED. UNFORESEEN CONDITIONS MAY EXIST. COOPERATION WITH OTHER TRADES IN ROUTING AND/OR BURIAL DEPTHS AS DETERMINED DURING CONSTRUCTION AND AS DIRECTED BY THE ARCHITECT MAY BE NECESSARY. IT IS INTENDED THAT SUCH DEVIATIONS SHALL BE CONSIDERED AS PART OF THIS CONTRACT. THE PLANS ARE NOT COMPLETELY TO SCALE. PLUMBING CONTRACTOR IS TO FIELD VERIFY DIMENSIONS OF ALL SITE UTILITIES, ETC., PRIOR TO BID AND INCLUDE ANY DEVIATIONS IN THE CONTRACT. PROJECT WILL NOT CONSIDERED COMPLETE UNTIL CONTRACTOR PROVIDES DETAILED AS-BUILTS AS PROJECT WAS INSTALLED. PLUMBING CONTRACTOR SHALL INSTRUCT OWNER'S MAINTENANCE PERSONNEL IN THE OPERATION AND REQUIRED MAINTENANCE OF ALL NEW PLUMBING SYSTEMS. PROVIDE SANITARY WASTE, VENT DOMESTIC WATER, AIR ECT. ROUGH-INS AND MAKE FINAL CONNECTIONS TO INCLUDE ALL NECESSARY RELATED STOPS, VALVES, TRAPS, QUICK CONNECTIONS ETC. AS REQUIRED TO ALL EQUIPMENT TO MAKE READY TO USE WHETHER FURNISHED BY THIS CONTRACTOR OR FURNISHED BY OTHERS. ABBREVIATIONS AD AP CO CW DN FCO FD HW HR IN MAX MIN NTS PC PSI SAN TYP V VTR W/ WCO ACCESS DOOR ACCESS PANEL CLEAN-OUT COLD WATER DOWN FLOOR CLEANOUT FLOOR DRAIN HOT WATER HOUR INCH OR INCHES MAXIMUM MINIMUM NOT TO SCALE PLUMBING CONTRACTOR POUNDS PER SQUARE INCH SANITARY TYPICAL VENT LINE VENT THRU ROOF WITH WALL CLEANOUT PLUMBING EQUIPMENT SCHEDULES EXPANSION TANK SCHEDULE WATER HEATER SERVING ELECTRIC WATER HEATER SCHEDULE TANK VOLUME ACCEPTANCE VOLUME PLUMBING LEGEND S V CW HW A P-I P-2 SANITARY WASTE VENT DOMESTIC COLD WATER HOT WATER SUPPLY PIPE CONTINUATION ELBOW UP ELBOW DOWN BRANCH OFF TOP OF MAIN BRANCH OFF BOTTOM OF MAIN TEE UP TEE DOWN SANITARY TEE BALL VALVE BALANCING VALVE AUXILIARY STRUCTURES FOR: SPLASH PARK RESTROOM DESIGN 3.5 PROVIDE ACCESS PANELS TO ALL VALVES WITHIN CHASES OR ABOVE NON-ACCESSIBLE CEILINGS. REFER TO ARCHITECTURAL DRAWINGS FOR CEILING TYPES. 3.6 FLOOR DRAIN TRAP SEALS SHALL HAVE AN APPROVED AUTOMATIC PRIMING DEVICE DESIGNED FOR THAT PURPOSE. 3.7 ALL CONCEALED TRAPS, PRIMERS, VALVES, CLEANOUTS, ETC. LOCATED IN TILED AREAS SHALL BE PROVIDED WITH AN ACCESS PANEL INSULATION 4.1 ABOVE GROUND HOT WATER - FIBERGLASS, 1" THICKNESS, ASJ JACKET, DOUBLE SEALING LAP JOINT, 0.24 K AT 75 F. INSULATION AND ADHESIVES OR ELASTOMERIC TYPE. PIPING INSTALLED IN RETURN AIR PLENUMS SHALL HAVE A MAXIMUM FLAME SPREAD RATING OF 25 AND A MAXIMUM SMOKE DEVELOPED RATING OF ABOVEGROUND CONDENSATE PIPING SHALL BE 1/2" FLEXIBLE UNICELLULAR POLYOLEFIN FOAM AND SHALL HAVE A MAXIMUM FLAME SPREAD RATING OF 25 AND A MAXIMUM SMOKE DEVELOPED RATING OF 50 - IMCOA "IMCOLOCK" VALVES AND COCKS 5.1 VALVES 2" AND SMALLER SHALL BE BALL VALVES, 150 PSI SWP, 400 PSI WOG. STANDARD PORT BALL, BRONZE TRIM, CAST BRONZE BODY, CHROMIUM-PLATED BRASS BALL, BRONZE NON-BLOWOUT STEM, TEFLON SEAT, DOUBLE O-RING STEM SEALS, ZINC-COATED STEEL HANDLE WITH PLASTIC COATED HAND GRIP, 90 DEGREE OPERATION FROM FULL OPEN TO TIGHT SHUT-OFF - STOCKHAM S214-BR-T-T, STOCKHAM S216-BR-T-S OR EQUAL. 5.2 CHECK VALVES, ROUGH BRASS, REGRINDING BRONZE DISC - STOCKHAM B-345; B-309 OR EQUAL STERILIZATION 6.1 DOMESTIC WATER PIPING SHALL BE THOROUGHLY FLUSHED OUT AND STERILIZED IN ACCORDANCE WITH THE STANDARD PLUMBING CODE. - END OF SECTION - GENERAL NOTES, LEGENDS, SPECIFICATIONS - PLUMBING PLUMBING SHEET INDEX DRAWING SHEET TITLE SCALE P0.1 GENERAL NOTES, LEGENDS, SPECIFICATIONS - PLUMBING NO SCALE P1.0 FLOOR PLANS & FIXTURE SCHEDULES - PLUMBING 1/4" = 1'-0" P2.0 RISER DIAGRAMS - PLUMBING NO SCALE P3.0 DETAILS - PLUMBING NO SCALE DJP TT

9 PLUMBING FIXTURE SCHEDULES WC-1 FLOOR MOUNTED WATER CLOSET MS-1 MOP SINK VITREOUS CHINA, 1.6 GALLON, FLOOR MOUNTED, SIPHON JET, ELONGATED CLOSET BOWL WITH 1-1/2" TOP SPUD. 1.6 GALLON CHROME PLATED FLUSH VALVE(EXPOSED), 1-INCH I.P.S. SCREW DRIVER ANGLE STOP WITH PROTECTIVE CAP, ADJUSTABLE TAILPIECE, VACUUM BREAKER FLUSH CONNECTION AND SPUD COUPLING FOR 1-1/2" TOP SPUD, DIE CAST WALL FLANGE WITH SET SCREW, SPUD FLANGE AND SOLID RING PIPE SUPPORT. SEAT SHALL BE EXTRA HEAVY SOLID PLASTIC WITH STAINLESS STEEL SELF SUSTAINING CHECK HINGE, OPEN FRONT LESS COVER. FLOOR MOUNTED PRECAST TERRAZO WITH STAINLESS STEEL CAP, 28" X 28" X 12" CRESCENT SHAPE, DRAIN BODY SHALL BE STAINLESS STEEL CAST INTEGRAL, AND SHALL PROVIDE FOR A CAULKED LEAD CONNECTION AND NOT LESS THAN 1" DEEP TO A 3" PIPE. PROVIDE WITH STAINLESS STEEL WALL GUARD. SERVICE FAUCET SHALL BE CHROME PLATED WITH RENEWABLE SEATS IN MONEL, VACUUM BREAKER, INTEGRAL STOPS, ADJUSTABLE WALL BRACE, PAIL HOOK, AND 3/4" HOSE THREAD ON SPOUT. 36" HOSE WITH 3/4" CHROME COUPLING AND WALL BRACKET. CHINA - AMERICAN STANDARD FLUSH VALVE - SLOAN ROYAL "II" 111-XL-YK SEAT - BEMIS SS/C SINK - STERN WILLIAMS CRS-2200 FAUCET - CHICAGO CP HOSE - WILLIAMS - T-35 WC-2 FLOOR MOUNTED ACCESSIBLE WATER CLOSET EWC-1 ACCESSIBLE ELECTRIC WATER COOLER UR-1 UR-2 L-1 VITREOUS CHINA, 1.6 GALLON, FLOOR MOUNTED, SIPHON JET, ELONGATED CLOSET BOWL WITH 1-1/2" TOP SPUD. 1.6 GALLON CHROME PLATED FLUSH VALVE(EXPOSED), 1-INCH I.P.S. SCREW DRIVER ANGLE STOP WITH PROTECTIVE CAP, ADJUSTABLE TAILPIECE, VACUUM BREAKER FLUSH CONNECTION AND SPUD COUPLING FOR 1-1/2" TOP SPUD, DIE CAST WALL FLANGE WITH SET SCREW, SPUD FLANGE, SOLID RING PIPE SUPPORT AND ADA HANDLE. SEAT SHALL BE EXTRA HEAVY SOLID PLASTIC WITH STAINLESS STEEL SELF SUSTAINING CHECK HINGE, OPEN FRONT LESS COVER. NOTE: FLUSH VALVE HANDLE SHALL FACE WIDE SIDE OF STALL. CHINA - AMERICAN STANDARD FLUSH VALVE - SLOAN ROYAL "II" 111-XL-YK SEAT - BEMIS SS/C WALL HUNG URINAL VITREOUS CHINA,.5 GALLON WALL HUNG, SIPHON JET URINAL WITH INTEGRAL FLUSHING RIM, INTEGRAL TRAP, WALL HANGERS, AND 2 INCH FEMALE FLANGED OUTLET CONNECTION. MANUAL OPERATED,.5 GALLON PER FLUSH CHROME PLATED FLUSH VALVE(EXPOSED), 3/4-INCH I.P.S. SCREWDRIVER CHECK ANGLE STOP WITH PROTECTIVE CAP, ADJUSTABLE TAILPIECE, VACUUM BREAKER FLUSH CONNECTION AND SPUD COUPLING FOR 3/4" TOP SPUD, DIE CAST WALL FLANGE WITH SET SCREW AND SPUD FLANGE. FULLY ADJUSTABLE URINAL CARRIER ADJUSTED TO STANDARD HEIGHT. CHINA - AMERICAN STANDARD FLUSH VALVE - SLOAN MODEL CARRIER - ZURN ZR-1222 ACCESSIBLE WALL HUNG URINAL SAME AS UR-1 EXCEPT MOUNTED AT ADA HEIGHT SELF-RIMMING LAVATORY VITREOUS CHINA LAVATORY, 20" X 17" OVAL, PUNCHED FOR SINGLE HOLE FITTING. SINGLE COLD WATER CHROME PLATED BRASS FAUCET, 0.5 GPM FLOW REGULATOR, CHROME PLATED PUSH BUTTON HANDLE WITH COLD WATER CODED INDEX. CHROME PLATED CAST GRID STRAINER WITH 1-1/4" TAILPIECE, CHROME PLATED 17 GAUGE 1-1/4" X 1-1/2" BRASS P-TRAP WITH CLEANOUT. 1/2" COMPRESSION X 3/8" COMPRESSION CHROME PLATED ANGLE SUPPLY STOPS WITH CHROME PLATED 12" FLEXIBLE RISERS AND ESCUTCHEONS. CHINA - AMERICAN STANDARD FAUCET - CHICAGO E2805 STRAINER/TRAP - MCGUIRE - 155A/8902 SUPPLIES - MCGUIRE CC SA-1 FD-1 WH-1 CO TYPE 304 STAINLESSS STEEL DRINKING FOUNTAIN POLISHED TO A #4 SATIN FINISH WITH DUAL HEIGHT RECEPTOR, SELF CLOSING FRONT MOUNTED PUSH BUTTON TYPE BUBBLERS, STRAINER AND TAILPIECE. SURFACE MOUNTED REFRIGERANT CHILLER UNIT CAPABLE OF 8 GPH OF 50 F AT AN AMBIEMT TEMPERATURE OF 90 F. ELECTRICAL CHARACTERISTICS - 115V AC, 60HZ, SINGLE PHASE. WATERSENTRY VII FILTER WITH 1,500 GALLON CAPACITY TO REMOVE CYSTS, LEAD AND CHLORINE. CHROME PLATED 17 GAUGE 1-1/4 X 1-1/2 BRASS P-TRAP WITH CLEANOUT. 3/8 INCH I.P.S. CHROME PLATED SUPPLY WITH LOOSE KEY STRAIGHT STOP AND WALL FLANGE. FOUNTAIN - ELKAY -EZSTL8C TRAP - MCGUIRE SUPPLY - MCGUIRE- 158LK SHOCK ARRESTER PISTON OPERATED, TYPE "K" COPPER BARREL WITH BRASS THREADED ADAPTOR. ALL JOINTS SHALL BE MADE WITH 95-5 LEAD FREE SOLDER. THE PISTON SHALL BE EQUIPPED WITH TWO (2) "O" RINGS TO PROVIDE A PERMANENT MECHANICAL BARRIER BETWEEN FLUID AND PRE-LOAD AIR CHARGE. ARRESTORS MAY BE INSTALLED IN VERTICAL AND HORIZONTAL POSITION. THE ARRESTOR SHALL BE FULLY GUARANTEED FOR ENTIRE SYSTEM LIFE. NOTE: SHOCK ARRESTORS SHALL BE PROVIDED AT ALL FIXTURES AND BATTERIES OF FIXTURES WHETHER OR NOT THEY ARE SHOWN ON THE DRAWINGS. PRECISION PLUMBING PRODUCTS - SC SERIES FLOOR DRAIN - TOILET ROOMS COATED CAST IRON BODY WITH BOTTOM OUTLET, COMBINATION INVERTIBLE MEMBRANE CLAMP AND ADJUSTABLE TYPE "S" NICKEL BRONZE STRAINER, 6" SQUARE TOP, TAPPED FOR TRAP PRIMER CONNECTION, VANDAL PROOF. ZURN - Z-415-P-6" X 6" TOP-VP WALL HYDRANT FREEZE PROOF WALL ANTI-SIPHON WALL HYDRANT COMPLETE COMPLETE WITH BRONZE CASING, VACUUM BREAKER, ALL BRONZE INTERIOR PARTS AND NON TURNING OPERATING ROD WITH FREE FLOATING COMPRESSION CLOSURE VALVE WITH CHROME FINISH AND OPERATING KEY. WOODFORD MODEL 65 CLEANOUTS AUXILIARY STRUCTURES FOR: SPLASH PARK RESTROOM DESIGN L-1 ACCESSIBLE WALL HUNG LAVATORY VITREOUS CHINA LAVATORY, 20" X 18", WITH FRONT OVERFLOW, SELF DRAINING DECK AREA & CONTOURED BACK W/ SIDE SPLASH PANELS, PROVIDE FIXTURE PUNCHED FOR COMBINATION FITTING ON 8-INCH CENTERS AND CONCEALED ARM CARRIER SUPPORT. 8" WIDESPREAD COMBINATION CHROME PLATED BRASS FAUCET, W/ RIGID GOOSENECK NOZZLE AND 2.0 GPM LAMINAR REGULATOR, VANDAL RESISTANT 4 INCH WRIST BLADE HANDLES WITH COLOR CODED INDEXES AND RENEWABLE SEATS IN MONEL, OUTLET OF SPOUT SHALL BE MINIMUM 5 INCHES ABOVE RIM OF FIXTURE. CHROME PLATED CAST BRASS GRID STRAINER WITH 1-1/4" O.D. OFFSET TAILPIECE, CHROME PLATED 17 GAUGE 1-1/4" X 1-1/2" BRASS P-TRAP W/ C.O. PLUG AND SLIP NUTS. PROVIDE P-TRAP & TAILPIECE WITH PREWRAPPED SEAMLESS MOLDED CLOSED CELL VINYL INSULATION WITH FLEXIBLE COLLARS TO ALLOW PIPE CONNECTION. PRE-WRAPPED DRAIN INSULATION KIT SHALL INCLUDE HOT AND COLD ANGLE STOP AND WATER SUPPLY COVERS OF SAME MATERIAL. 3/8" I.P.S. CHROME PLATED ANGLE SUPPLY, LOOSE KEY STOP, REDUCER, WROUGHT BRASS DEEP BELL FLANGE ESCUTCHEON AND 1/2" CHROME PLATED COPPER EXTENSION TUBE. CONCEALED ARMS FLOOR MOUNTED CARRIER: COATED STEEL UPRIGHTS WITH WELDED FEET, CAST IRON ADJUSTABLE HEADERS, STEEL SLEEVES, ALIGNMENT TRUSS AND FASTENERS GENERAL(ALL FLOOR CLEANOUTS): DURO-COATED CAST IRON CLEANOUT WITH MEMBRANE FLANGE WITH CADMIUM PLATED CAST IRON COUNTERSUNK PLUG. CLEANOUT CAN BE ADJUSTED TO FINISH FLOOR LEVEL AFTER CONCRETE HAS SET. FLOOR: HEAVY DUTY ROUND SCORIATED NICKEL BRONZE TOP EXTERIOR: HEAVY DUTY ROUND SCORIATED NICKEL BRONZE TOP. PROVIDE WITH 18" X 4" THICK CONCRETE COLLAR, SEE DETAIL. WALL: CAST IRON CLEANOUT TEE, CADMIUM PLATED CAST IRON COUNTERSUNK PLUG, SMOOTH SQUARE NICKEL BRONZE WALL ACCESS COVER AND FRAME. FCO - FLOOR - ZURN - ZN-1405 EC0 - EXTERIOR - ZURN - ZN-1406 WCO - WALL - ZURN FLOOR PLANS & FIXTURE SCHEDULES - PLUMBING CHINA -AMERICAN STANDARD FAUCET - CHICAGO E29VP STRAINER/TRAP - MCGUIRE -155WC/PW 2150 WC SUPPLIES - MCGUIRE - H170LK CARRIER - ZURN ZR DJP TT

10 PRESSURE PIPING RISER DIAGRAM No Scale GRAVITY PIPING RISER DIAGRAM No Scale DJP TT RISER DIAGRAMS - PLUMBING AUXILIARY STRUCTURES FOR: SPLASH PARK RESTROOM DESIGN

11 TRAP PRIMER WATER CLOSET ELECTRIC WATER HEATER DJP TT DETAILS - PLUMBING AUXILIARY STRUCTURES FOR: SPLASH PARK RESTROOM DESIGN