1 February 7, 2013 The Home Doctor, Inc. Property: HUNTER GATES RD. LESTER, AL Client: JOHN DOE

2 HOME INSPECTIONS With over 10,000 since SUMMARY PAGE CLIENT(S): JOHN DOE ADDRESS: HUNTER GATES, LESTER, AL DATE OF INSPECTION: November 16, 2012 INSPECTOR: GUINN LAXSON LISTED BELOW ARE RECOMMENDATIONS FOR REPAIRS: STRUCTURAL OR AFFECTING THE STRUCTURE: - INSTALL ADDITIONAL FLOOR JOISTS SUPPORT. THE SPAN IS TOO GREAT FOR SIZE. -INSTALL PROPER BRACING AT SAGGING RAFTERS AT REAR SLOPE OF BREEZEWAY. HEATING, VENTILATION, AND COOLING: -INSTALL HVAC DUCT BOOT INSULATION IN THE CRAWL SPACE. -INSTALL MISSING MAIN AIR RETURN HVAC DUCT INSULATION IN THE CRAWL SPACE. ELECTRICAL: - PROPERLY INSTALL MASTER GFI IN UPSTAIRS BATH TO OPERATE PROPERLY. -REPAIR GFI WALL OUTLET AT BREEZEWAY TO OPERATE. -PROPERLY ATTACH THE DOWNSTAIRS BEDROOM CLOSET CEILING LIGHT. -COMPLETE INSTALLATION OF ATTIC LIGHT AND SWITCH. -INSTALL ELECTRICAL BOX AND COVER AT WIRE SPLICE IN THE ATTIC -COMPLETE ELECTRICAL INSTALLATION OF EAVE LIGHT AT SW CORNER OF DETACHED GARAGE. -INSTALL GFI PROTECTION ALL DETACHED GARAGE 1ST FLOOR ELECTRICAL WALL OUTLETS. -REPAIR OPEN GROUND DETACHED GARAGE UPSTAIRS SOUTH WALL OUTLETS. PLUMBING: - REPAIR UPSTAIRS MASTER BATH VANITY FAUCET LEAK. -REPAIR THE LEAKING DOWNSTAIRS BATHTUB FAUCET. -INSTALL WATER HEATER RELIEF VALVE EXTENSION TO EXTERIOR OF THE CRAWL SPACE. -REPAIR COMODE SEAL LEAK AT DOWNSTAIRS BATH. SAFETY: -INSTALL PROPER RAILING AND BALLISTERS FOR DETACHED GARAGE STAIRWAY. -INSTALL A METAL FIRESTOP IN THE ATTIC AROUND CHIMNEY FLUE. -REPAIR NORTH GARAGE DOOR SAFETY REVERSED TO OPERATE PROPERLY. -RELEASE PAINT STUCK WINDOWS. OTHER: - RAISE EXTERIOR DOORS, REPAIR, OR LOWER THE FLOORS FOR PROPER OPERATION. -REPAIR DAMAGED FOUNDATION VENT SCREENING. - REPAIR VARIOUS SIDING WHICH APPEARS TO BE DAMAGED BY WEED EATERS OR LAWN MOWER. -INSTALL MISSING GUTTER ELBOWS. -REATTACH FRONT GUTTER DOWNSPOUT. -REPAIR DETERIORATED REAR SECOND FLOOR WINDOW NOSEPIECE. -REPAIR DETERIORATED GARAGE REAR EXTERIOR DOOR.

3 -INSTALL MISSING ATTIC WALL INSULATION. -REPAIR BROKEN UPSTAIRS REAR FIXED WINDOW. -REPAIR UPSTAIRS NORTH BEDROOM WINDOW WITH THERMAL FAILURE. READ ENTIRE REPORT FOR ADDITIONAL NOTES OR RECOMMENDATIONS.The cost of repairs will vary with the contractor. If there are any questions concerning these recommendations, feel free to call us at the numbers below and we will return your call as soon as possible. The greatest compliment we can receive is for you to refer us to your friends. If we can be of further service contact us at the numbers below OR (LOCAL)

4 Supplemental Picture Page # HUNTER GATES RD., LESTER, AL RAISE EXTERIOR DOORS, REPAIR, OR LOWER THE FLOORS FOR PROPER OPERATION. - PROPERLY INSTALL MASTER GFI IN UPSTAIRS BATH TO OPERATE PROPERLY. -REATTACH FRONT GUTTER DOWNSPOUT. -INSTALL MISSING GUTTER ELBOWS. MONITOR ROOF AND SIDING CONNECTIONS. -REPAIR DETERIORATED GARAGE REAR EXTERIOR DOOR.

5 Supplemental Picture Page # HUNTER GATES RD., LESTER, AL WATER STAINING AT GARAGE FLOOR DUE WATER ENTRY AT FRONT DOOR. -INSTALL PROPER RAILING AND BALLISTERS FOR DETACHED GARAGE STAIRWAY. -INSTALL MISSING ATTIC WALL INSULATION. -INSTALL A METAL FIRESTOP IN THE ATTIC AROUND CHIMNEY FLUE. -COMPLETE INSTALLATION OF ATTIC LIGHT AND SWITCH. INSTALL ELECTRICAL BOX AND COVER AT WIRE SPLICE IN THE ATTIC

6 Supplemental Picture Page # HUNTER GATES RD., LESTER, AL INSTALL ELECTRICAL BOX AND COVER AT WIRE SPLICE IN THE ATTIC -INSTALL WATER HEATER RELIEF VALVE EXTENSION TO EXTERIOR OF THE CRAWL SPACE. -REPAIR COMODE SEAL LEAK AT DOWNSTAIRS BATH. -INSTALL HVAC DUCT BOOT INSULATION IN THE CRAWL SPACE. -REPAIR BROKEN UPSTAIRS REAR FIXED WINDOW. -INSTALL MISSING MAIN AIR RETURN HVAC DUCT INSULATION IN THE CRAWL SPACE.

7 Client JOHN DOE The Home Doctor, Inc. "We Make House Calls!" 27355NICK DAVIS ROAD ATHENS AL Property Address HUNTER GATES RD. LESTER, AL Inspection Inspection Date: Weather Conditions: Inspector's Name: Inspection Cert No: 11/16/2012 Dry GUINN LAXSON AL LICENSE # HIOO74 February 7, 2013 Occupied Client Present Seller Present Agent Present Listing Agent Present Structure House Faces East Report Summary Exter. Wall Type: Wood Frame Structure Type: Single Family Approximate Year Built: 1993 Bedrooms: 2 Bathrooms: 2 Inspector's Recommendations: SEE ATTACHED SUMMARY SHEET Scope of Inspection Survey The findings, however, are limited to only those areas readily accessible and visible to you during the inspection. Limitations of Liability The Home Doctor, Inc. limits it's liability to the fee paid. The lack of mention of other specific types of problems by The Home Doctor, Inc. does not mean that other types of problems do not exist. It means that by using accepted normal visual techniques, the report covers most of the standard issue's normally found in a home inspection. The generated report is just a reflection of problems you discover when performing the inspection. Keep in mind that other problems may exist during or after you perform the inspection. The Home Doctor does not produce a code compliance report. The inspection survey report does not include nor does it require lifting carpet, moving furniture, or removal or dismantling of any systems throughout the structure. The Home Doctor, Inc. only expects that you will inspect readily accessible and visible areas. The Home Doctor, Inc. makes no warranties either expressed or implied of the safety, condition, value, serviceability, or any other aspect of the structural components inspected. Inspector's Signature Date:

8 26147 HUNTER GATES RD., LESTER, AL Page #2 Thursday, February 07, 2013 Exterior Site Assessment Driveway Gravel Grade and Slope Flat NOTE: Water problems/standing water can be seasonal and may not be detected. See owner for history of any previous water problems. Exterior Structure Assessment Foundation Block/Stone, Crawl Space One or More Open Vent Screens Noted (Potential Animal or Rodent Entry) Siding Vinyl All Sides Viewable, More than One Story SOME SIDING REPAIRS HAVE BEEN ATTEMPTED AT NORTH WALL OF THE HOUSE. - REPAIR VARIOUS SIDING WHICH APPEARS TO BE DAMAGED BY WEED EATERS OR LAWN MOWER. NOTE: Siding is viewed from ground level. Front Entry Door Wood Patio Door Metal - RAISE EXTERIOR DOORS, REPAIR, OR LOWER THE FLOORS FOR PROPER OPERATION. Doors (Other Exterior) Metal -INSTALL PROPER RAILING AND BALLISTERS FOR DETACHED GARAGE STAIRWAY. -REPAIR DETERIORATED GARAGE REAR EXTERIOR DOOR. Windows (Exterior) Double Pane, Wood -REPAIR DETERIORATED REAR SECOND FLOOR WINDOW NOSEPIECE. -REPAIR BROKEN UPSTAIRS REAR FIXED WINDOW. -REPAIR UPSTAIRS NORTH BEDROOM WINDOW WITH THERMAL FAILURE. Exterior Structure Assessment Windows (Exterior) Double Pane, Wood NOTE: Due to weather and light conditions, Integrity makes no guaranties that thermal seals are in tact. Roof Metal Roof Viewed: From Edge; 2 Layers; Approx. Life Expectancy: Over 10 Years Appears to have Useful Life NOTE: THE HOME DOCTOR, INC. DOES NOT GUARANTEE AGAINST LEAKS! Gutters and Downspouts Aluminum -INSTALL MISSING GUTTER ELBOWS. -REATTACH FRONT GUTTER DOWNSPOUT. NOTE: Gutter drainage not tested for proper operation. Soffit/Eave Vinyl, Closed Soffit, All Sides Viewable, More than One Story Attic Framing: Rafter, Sheathing: O.S.B. Board Insulation: Fiberglass Batts, Cellulose; Approx. Rating: 19 Past Leak Stains Noted at Chimney, -INSTALL PROPER BRACING AT SAGGING RAFTERS AT REAR SLOPE OF BREEZEWAY. -INSTALL A FIRESTOP IN THE ATTIC AROUND CHIMNEY FLUE. -INSTALL MISSING ATTIC WALL INSULATION. NOTE: Attic will be inspected from access opening if insulation is above framing. Garage, Deck, Porch & Patio Garage & Storage Attached THE WASHING OF THE SOIL AT SW CORNER IS EVIDENCE OF INADEQUATE FOOTINGS AT DETACHED GARAGE. STAINED OSB IN DETACHED GARAGE APPEARS TO BE DUE TO WATER ENTRY AT FRONT OF THE GARAGE. -REPAIR NORTH GARAGE DOOR SAFETY REVERSED TO OPERATE PROPERLY. Deck Treated Wood - INSTALL ADDITIONAL FLOOR JOISTS SUPPORT. THE SPAN IS TOO GREAT FOR SIZE.

9 26147 HUNTER GATES RD., LESTER, AL Page #3 Thursday, February 07, 2013 Substructure Inspection Crawl Space Joist, ENTERED THE CRAWL SPACE, Vapor Barrier Type: Black Plastic Plumbing (Substructure) Supply: Plastic, Drain: PVC Plastic -INSTALL WATER HEATER RELIEF VALVE EXTENSION TO EXTERIOR OF THE CRAWL SPACE. -INSTALL COMODE SEAL LEAK AT DOWNSTAIRS BATH. Exterior Utilities Exterior Waste Drain Private Septic Systems are not Inspected Plumbing (Exterior) Plastic, Main Shut Off Valve: Street Gas or Oil (Exterior) Propane NO GAS AVAILABLE FOR TESTING Electrical (Exterior) Underground, Breakers, Service Grounded to Exterior Ground Rod, Service Conductor Type: Aluminum -REPAIR GFI WALL OUTLET AT BREEZEWAY TO OPERATE. -INSTALL GFI PROTECTION ALL DETACHED GARAGE 1ST FLOOR ELECTRICAL WALL OUTLETS. -REPAIR OPEN GROUND DETACHED GARAGE UPSTAIRS SOUTH WALL OUTLETS. Interior Structure Assessment Living Room Living Room Kitchen Sinks, Countertops and Cabinets Counter Top: Laminate Sinks, Counters and Cabinets Appear to be Serviceable Kitchen Flooring, Walls and Ceilings Floor Covering: Wood Flooring Interior Structure Assessment Kitchen Flooring, Walls and Ceilings Floor Covering: Wood Kitchen Appliances Electric, Range, Dishwasher, Built in Microwave Laundry Room Location: Main Floor, Electric Laundry Room NOTE: Clothes washer and dryer function are not tested. Hallways Hallway(s) Appear Serviceable Windows (Interior) Appear Serviceable -RELEASE PAINT STUCK WINDOWS. Interior Utilities Water Heater Electric, PIPE EXTENSION, RELIEF VALVE, LAUNDRY 50 Gal Appear Serviceable Electrical (Interior) Breakers, 3 Wire Outlets, Copper Wire to Lower Branch Circuits, Amperage: 200, Amperage: 100 Main Disconnect Located: Other; Visible Wire Type: Romex Appear Serviceable -PROPERLY ATTACH THE DOWNSTAIRS BEDROOM CLOSET CEILING LIGHT. -COMPLETE INSTALLATION OF ATTIC LIGHT AND SWITCH. -INSTALL ELECTRICAL BOX AND COVER AT WIRE SPLICE IN THE ATTIC -COMPLETE ELECTRICAL INSTALLATION OF EAVE LIGHT AT SW CORNER OF DETACHED GARAGE. NOTE: Electrical inspection is visual only and not intended to be all-inclusive. Receptacles throughout structure have only been spot checked, and just those which were readily accessible to the inspector. This check does not imply a warranty or guarantee of condition or safety of any of the electrical system. An undiscovered condition may exist. Heating System ELECTRIC PACKAGE HEAT PUMP, ELECTRIC SPLIT HEAT PUMP, FORCED AIR FURNACE

10 26147 HUNTER GATES RD., LESTER, AL Page #4 Thursday, February 07, INSTALL MISSING INSULATION FOR HVAC DUCT BOOTS. -INSTALL MISSING INSULATION FOR MAIN AIR RETURN DUCT IN THE CRAWL SPACE. REPLACE OR CLEAN FILTER EVERY 30 TO 60 DAYS. NOTE: Heating and cooling systems are check only for basic functions; this is not an all-inclusive system check. Internal components are not inspected including heat exchanger. Cooling System Central A/C, Heat Pump Fireplace/Wood Stove Gas Log, METAL PRE-FAB, Chimney Type: Wood Chase, with Metal Liner NO GAS AVAILABLE FOR TESTING NOTE: Fireplace and woodstoves require regular maintenance and inspection to ensure safe operation. This inspection reports is not a warranty of condition or safety of any fireplace or woodstove in use. This is not a certification. Smoke Detectors Hardwire Smoke Detector(s) Pass above Named Tests NOTE: Smoke detectors require regular testing and maintenance to ensure proper operation. This is not a guarantee of proper function. Bed and Bath Bedroom #1 (Master) - MASTER Bedroom(s) Appear Serviceable - REPAIR UPSTAIRS MASTER BATH VANITY FAUCET LEAK. Bedroom #2 - DOWNSTAIRS Bedroom(s) Appear Serviceable Bathroom #1 - DOWNSTAIRS Full Bath Bathroom(s) Appear Serviceable Fixtures: Bathroom Fixtures Appear Serviceable Electrical: Bathroom #2 - MASTER Full Bath Bathroom(s) Appear Serviceable Fixtures: Bathroom Fixtures Appear Serviceable Electrical: Bed and Bath Bathroom #2 - MASTER Full Bath -REPAIR THE LEAKING DOWNSTAIRS BATHTUB FAUCET., - PROPERLY INSTALL MASTER GFI IN UPSTAIRS BATH TO OPERATE PROPERLY.