PROPOSED PUBLIC TOILET FACILITIES PEGASUS TOWN, SITE PLAN. 38 colombo street, christchurch. ph fax

Size: px
Start display at page:

Download "PROPOSED PUBLIC TOILET FACILITIES PEGASUS TOWN, SITE PLAN. 38 colombo street, christchurch. ph fax"

Transcription

1 FOR TODD PROPERTY PEGSUS TOWN LTD SITE PLN 1

2 190 1, , Exterior recessed soffit light x 6 ( Switched from daylight sensor ) Mag lock to door. Mag lock to door , llproof Floor waste with P trap. urns & Ferrall W2 wash basin fixings from service duct. Franke FRFM5 Stainless Steel Disabled toilet pan P trap through wall into service duct. Height to comply with NZC G1 toilet roll dispenser Distribution board. Socket outlet. grab rail 80mm dia Floor Gully vent tap WH WC pan ulkhead light fitting switch. llproof Floor waste with P trap 65mm floor wastes to fall at 1:50 under slab to floor gully in service duct. 40mm dia. wastes from whb's to connect to floor gully below slab. ( Or gully Riser above slab ). 65mm dia pipes below floor 700 grab rail toilet roll dispenser 450 External overflow relief gully. Tap over power box 1,053 65mm dia DP 7,590 FLOOR PLNS Scale 1 : mm dia Stormwater drain to fall at 1:120 to stormwater system. FOR WIMKRIRI DISTRICT COUNCIL FLOOR PLNS 2

3 200 pfc fascia 140 x 45 timber framing shown dotted. 140 x 45 timber framing shown dotted. 200 pfc fascia 200 pfc fascia 4 o fall to roof. 4 o fall to roof. 140 x 45 timber framing shown dotted. Transluscent sheeting to skylights Transluscent sheeting to skylights 140 x 45 timber framing shown dotted. ROOF FRMING PLNS Scale 1 : 25 REVISION - FOR CONSTRUCTION 11/09/12 FOR TODD PROPERTY PEGSUS TOWN LTD ROOF FRMING PLN 3

4 200 PFC fascia as detailed. 9mm Eterpan Soffit lining. 190mm concrete block walls as detailed. Timber battens fixed over DPC to blockwork. Solid core steel faced doors NORTH ELEVTION WEST ELEVTION 200 PFC fascia as detailed. 9mm Eterpan Soffit lining. 190mm concrete block walls as detailed. Timber battens fixed over DPC to blockwork. Insitu surround to toilet block. EST ELEVTION SOUTH ELEVTION FOR WIMKRIRI DISTRICT COUNCIL ELEVTIONS 4

5 200 x 75 PFC. Note base to line with soffit. ( 9mm below 150 PFC's ) V Rib profiled colorsteel Maxx roofing screw fixed over roofing underlay to 140 x 45 H3.1 purlins , , mm Eterpan sheeting screw fixed through 12mm H3.1 ply to framing. 9mm Eterpan sheeting to ceilings. Screw fix to 70 x 35 ceiling battens. V Rib profiled Transluscent sheeting to panels shown. 90 x 45 timber slats dyna bolted to concrete blocks at crs. 190mm concrete block walls filled & reinforced to engineers recommendations & drawings. Painted concrete block finish to interior walls. Caroma water cisterns installed in service duct, complete with all fittings and flush pipe. Provide & install Caroma Remote flush button mounted 1050mm above floor level. Delabie DE Tempostop TC bib tap. urns & Ferrall W2 wash basin fixings from service duct. 100mm thick insitu to 10mm fall away from walls. room finish as specified. Franke FRFM5 Stainless Steel Disabled toilet pan P trap through wall into service duct. Height to comply with NZC G1 Floor & Foundations as detailed by the engineer. SECTION Scale 1 : 20 FOR TODD PROPERTY PEGSUS TOWN LTD SECTION 5

6 V Rib profiled colorsteel Maxx roofing screw fixed over roofing underlay to 140 x 45 H3.1 purlins. Soil stack vent 80mm dia. Dektite DFE103g for 0-45 degree roofs. 150 Colorsteel Maxx perimeter flashing to sizes indicated. Low pitch eaves flashing under roofing & underlay x 75 PFC. Note base to line with soffit. ( 9mm below base of 150 PFC's ) 125 x 125 colorsteel Maxx spouting PFC fascia. ase to finish level with soffit lining ( 9mm below base of other 150 PFC beams & rafters. ) 9mm Eterpan sheeting screw fixed through 12mm H3.1 ply to framing. 190mm HONED concrete block walls filled & reinforced to engineers drawings. Painted. Caroma water cisterns installed in service duct, complete with all fittings and flush pipe. Provide & install Caroma remote flush button mounted 1050mm above floor level , mm Eterpan sheeting to ceilings. Screw fix to 70 x 35 ceiling battens. V Rib profiled Transluscent sheeting to panels shown. Painted concrete block finish to interior walls. Delabie DE Tempostop TC bib tap. 2, solid core steel faced doors in 90 x 45 rebated H3.2 timber frame bolted to blockwork. Note: Doors & jambs to be 150mm short of floor. 100mm dia soil stack in service space beyond. Stack changed to 80mm dia as soil stack vent. 1,050 Franke FR-NMX450 Guardian wash basin mm dia stormwater drain to fall at 1:120 to soak hole. SECTION Scale 1 : 20 10mm fall in floor slab to floor waste. REVISION - FOR CONSTRUCTION 11/09/12 FOR WIMKRIRI DISTRICT COUNCIL SECTION 6

7 32mm Ø stainless steel grab rail 750 x 750 MacDonald industries 0215 Stainless steel paper towel dispenser centre grab rail Franke FRFM5 Stainless Steel Disabled toilet pan P trap through wall into service duct. Height to comply with NZC G FIXTURE SETOUT Scale 1 : 20 FOR TODD PROPERTY PEGSUS TOWN LTD CCESSILE TOILET LYOUT 7