Presentation of the cooperation possibilites

Size: px
Start display at page:

Download "Presentation of the cooperation possibilites"

Transcription

1 Pozaryskiego St. 28, Presentation of the cooperation possibilites Ph.D., Eng. Krzysztof Tomczuk, Manager of Marketing and Scientific Information Department

2 has 4 fields of activity: 1. Testing and Certyfication of electrotechnical products. 2. Research and Development (R&D) support for companies. 3. Joint scientific projects (with companies). 4. Production of insulation materials in our factory. Selected diplomas and awards form Innovation Exhibitions form Poland, Germany and other countries. 2

3 Activity 1: Testing and Certyfication of electrotechnical products. has accredited laboratories that allow carrying out applied research and the issuance of a certificate confirming that the product complies with the applicable standards. Testing and certification relate to lighting equipment, sources of light, lamps, lighting power systems, extension cords, electric toys, road signs with ability to show changeable messages, household equipment, power tools, electrical machines, circuit breakers and residual current devices for household use. Switchgear for high and low voltage DC and AC, fuses, circuit breakers, transformers, busbars and many others MVA short circuit generator. Internal arc fault test. Exciter of the short circuit generator. 3

4 Activity 1: A). Certification possibilities: Electrotechical Products Certification Unit. Acc. No. AC168 Adress: Warsaw, 28 Mieczysława Pożaryskiego St. AC168 Template of the certificate 4

5 Activity 1: B). Testing possibilities: IEL has 3 accredited by Polish Accreditation Centre laboratories: 1. Switchgear and Controlgear Laboratory. Acc. No. AB074 Adress: Warsaw, 28 Mieczysława Pożaryskiego St. 2. Testing and Calibration Laboratory. Acc. No. AB022, AP102 Adress: Warsaw, 28 Mieczysława Pożaryskiego St. AB074 AB022 AB Testing laboratory. Acc. No. AB067 Adress: Wrocław, 55/61 Marie Curie Sklodowsk St. AP102 5

6 Testing possibilities: 1. Switchgear and Controlgear Laboratory in Warsaw. Acc. No. AB074 AB074 6

7 1. Switchgear and Controlgear laboratory in Warsaw. Acc. No. AB074 AB074 Laboratory control room Laboratory electric waveforms recorder 7

8 1. Switchgear and Controlgear laboratory in Warsaw. Acc. No. AB074 AB074 Short-circuit generator 2500 MVA Short-ciucuit transformers Excication of Short-circuit generator Temperature-rise test high current transformers Adres: Warszawa, ul. M. Pożaryskiego 28, Tel: , , 8

9 1. Switchgear and Controlgear Laboratory in Warsaw. Acc. No. AB074 AB074 Parameters of the Switchgear and Controlgear Laboratory. Internal arc failure tests. Adress: Warsaw, 28 Mieczysława Pożaryskiego St. Tel: , , 9

10 1. Switchgear and Controlgear Laboratory in Warsaw. Acc. No. AB074 AB Hz, High Voltage transformer. max. 600 kv, 50 Hz 1.2/50 us Impulse High Voltage generator. max kv, 1.2 / 50 us Adress: Warsaw, 28 Mieczysława Pożaryskiego St. Tel: , , zwarcia@iel.waw.pl 10

11 1. Switchgear and Controlgear Laboratory in Warsaw. Acc. No. AB074 AB074 Temperature-rise test high current transformers For AC current, max. 12kA For DC current max. 10 ka Transformetr during temperature-rise test max. 180 termocouples K type Adress: Warsaw, 28 Mieczysława Pożaryskiego St. Tel: , , zwarcia@iel.waw.pl 11

12 1. Switchgear and Controlgear Laboratory in Warsaw. Acc. No. AB074 AB074 Low resistance measurement device Test current up tp 100A Winding low resistance measurement device Test currest up to 25A Adress: Warsaw, 28 Mieczysława Pożaryskiego St. Tel: , , 12

13 1. Switchgear and Controlgear Laboratory in Warsaw. Acc. No. AB074 AB074 Dust chamber fo IP protection degree tests. Test stand for mechanical tests. Up tp IK 10 up to - IP 68 Capacity chamber m3 Apparatus during tests in dust chamer. Test of water ingress inside the enclosure. Adress: Warsaw, 28 Mieczysława Pożaryskiego St. Tel: , , zwarcia@iel.waw.pl 13

14 1. Switchgear and Controlgear Laboratory in Warsaw. Acc. No. AB074 AB074 Climatic chamber tests Temperature range: -70 ºC +85 ºC Climatic chamber disconnector test (low temperature, high humidity) Humidity range: 10% 90% RH Adress: Warsaw, 28 Mieczysława Pożaryskiego St. Tel: , , 14

15 1. Switchgear and Controlgear Laboratory in Warsaw. Acc. No. AB074 AB074 EMC chamber EMC chamber Faraday s cage Adress: Warsaw, 28 Mieczysława Pożaryskiego St. Tel: , , zwarcia@iel.waw.pl 15

16 Testing possibilities: 2. Testing and Calibration Laboratory in Warsaw. Acc. No. AB022, AP102 AP102 AB022 Adress: Warsaw, 28 Mieczysława Pożaryskiego St. Tel: , , 16

17 2. Testing and Calibration Laboratory in Warsaw. Acc. No. AB022, AP102 AB022 EMC tests Light sources tests AP102 Noise tests Luminous flux tests in Ulbricht sphere Adress: Warsaw, 28 Mieczysława Pożaryskiego St. Tel: , , 17

18 2. Testing and Calibration Laboratory in Warsaw. Acc. No. AB022, AP102 Selected tests in Testing and Calibration Laboratory : Traditional bulbs, halogen bulbs, low dimensions bulbs. Discharge lamps, Fluorescent lamps. Luminaires. Light systems. High voltage starters for discharge lamps. Electronic ballasts. Extension leads, for home and public applications Sockets and plugs for home applications. Electric toys. Traffic and road signs with vartable content. Electric machines noise measurements Electromagnetic Compability (EMC) Emission of conducted disturbances: 9kHz 30 MHz Emission of radiated disturbances: 30 MHz 1 GHz Power of disturbances: 30 MHz 300 MHz Climatic chamber: Temp: -60ºC +180ºC, Humidity: up to 98%RH Light radiation spectrum and radiation energy for VIS i UV AB022 AP102 Adress: Warsaw, 28 Mieczysława Pożaryskiego St. Tel: , , badania@iel.waw.pl 18

19 2. Testing and Calibration Laboratory in Warsaw. Acc. No. AB022, AP102 Selected tests in Testing and Calibration Laboratory (in the customer company): Illuminance, luminance, Light chomaticy, In offices, rooms, halls, internal communication paths. In Railway and public transport vehicles. In workplaces AB022 Selected calibration possibilities AP102 : DC voltage and DC current (up to 1000V DC and up to 20A DC). AC voltage and AC current in the frequency range from 40Hz uo to 10 khz up to 1000V AC up tp 20A AC. Resistance Ohm meters: analog and digital up to 10 GΩ (10 giga ohms). Shunts up tp 10 GΩ (10 giga ohms). DC klilovolt meters: analog and digital: up tp 100kV DC AC klilovolt meters: analog and digital: up to 180kV AC AP102 Adress: Warsaw, 28 Mieczysława Pożaryskiego St. Tel: , , badania@iel.waw.pl 19

20 2. Testing and Calibration Laboratory in Warsaw. Acc. No. AB022, AP102 AB022 Calibtaion of multimeters AP102 Calibration of energy meters Adress: Warsaw, 28 Mieczysława Pożaryskiego St. Tel: , , 20

21 Testing possibilities: 3. Testing Laboratory in Wrocław (Electrotechnical Materials Laboratory) Acc. No. AB067 AB067 Adress: Wrocław, 55/61 Marie Curie-Skłodowskiej St., Tel: , 21

22 3. Testing Laboratory in Wrocław. Acc. No. AB067 AB067 Climatic chamber Creeping currents tests High Voltage impulse generator 1.2/50us Measurements of impedance, admitance, capacitance, loses in frquency range between 1MHz and 3 GHz. Adress: Wrocław, 55/61 Marie Curie-Skłodowskiej St., Tel: , ielow@iel.wroc.pl 22

23 3. Testing Laboratory in Wrocław. Acc. No. AB067 Selected tests in Testing laboratory in Wrocław: Resistance to fire hazard (heat wire method) The minimum oxygen concentration supporting fire. Tests of flammability category. AB067 Insulation resistance of the coating to stretch before and after aging. Water absorption. DC current resistance Insulation resistance. Surface resistance. Solar radiation simulator Electrotechnical materials: Mechanical resistance to tension, compression and bending in a temperature range from + 20 C to C. The range of force: compressive strength 80 kn, bending 10 kn Adress: Wrocław, 55/61 Marie Curie-Skłodowskiej St., Tel: , ielow@iel.wroc.pl 23

24 Photos taken during tests 24

25 EMC chamber EMC chamber EMC chamber Meaurement system for testing the influence low frequency magnetic fields into the human body. 25

26 Dust chamber IP protection tests Low temperatures chamber Vibration test stand 26

27 Climatic chamber Climatic chamber Test stand for energetic devices testing procedures 27

28 Mechanical tests Tests of energetic devices 28

29 Short-Circuits test Tests of energetic devices Test stand for mechanical tests 29

30 Testing possibilities: 3 other IEL laboratories without accreditation 4. Power Converters Laboratory 5. Electric Traction Laboratory 6. Electric Machines and Electric Drives Laboratory 30

31 4. Power Converters Laboratory in Warsaw View of the Power Converters Laboratory 2.5 MVA transformer Variable transformer 630 kva Electric load 2.5 MVA Crane 4.5 Tons 31

32 4. Power Converters Laboratory in Warsaw Alternating Current (AC) Supply line 15kV Supply line 6kV Max 100A Max 250A Variable transformer Input voltage: 6kV AC, 50Hz Output voltage: kV AC Output Power: 600kVA Direct Current (DC) Outout voltage Electric load (resistance) Load power Output voltage: kV DC Output Power: 600kVA 2.5MVA No. of resistances 16 pieces (300A or 600A) Min. resistance Ω (up to 600A) Max. resistance Ω (up to 300A) Parameters of Power Converters Laboratory 32

33 5. Electric Traction Laboratory in Warsaw. High power DC/AC converter for locomotive drive test stand. Railway static converters test stand 33

34 Direct Current (DC) - supplied from electric machine generators ZM1 2x15V / 2000A ZM2 150V / 305A ZM3 230V / 350A ZM4 460V / 180A ZM6 3300V / 150A or 650V / 545A ZM7 30V / 1000A Direct Current (DC) - supplied from transformers and rectifiers ZP1, ZP2, ZP3, ZP V / 80A ZP5, ZP V / 390A ZP V / 130A ZP8 2800V / 500A or 660V / 1000A 5. Electric Traction Laboratory in Warsaw ZP9 3300V / 500A or 660V / 1000A Electric load (resistance) with insulation of 3kVDC Load power 2.5MVA No. of resistances 16 pieces (300A or 600A) Min. resistance Ω (up to 600A) Max. resistance Ω (up to 300A) Crane up to 6 tons. Parameters of Electric Traction Laboratory 34

35 6. Laboratory of Electric Machines and Electric Drives (up tp 400kW) 35

36 Description of other acivities of IEL

37 Activity 2: Research and Development (R&D) support for companies. The staff of the provides support for research and development (R&D) for companies in various fields of electrical engineering. We develop, modernize, products and equipment. We have experience in the design of energy-efficient LED lighting, battery energy storage, wireless transmission of electricity, low speed wind generators, electrical machines, static converters, electric drives for bicycles, cars and locomotives. We develop high-power converters for use in electric traction, energetics and power generation in order to improve the quality of electricity, and for large renewable energy installations. We design and manufacture high power inductors and high frequency high power transformers especially for power converters. We conduct the consultative work in our field. 2MJ, 150kW supercapacitive energy storage bank for traction substations for regenerative breaking. 3kVDC, 5MW, High power DC/AC drive and 3kV, 2x160kW static converters for railway. 3000VDC, 1700A 12 pulse traction rectifier. 1MW, 6kVAC multilevel power converter 37

38 Activity 3: Joint scientific projects. (IEL) conducts research activities under national and international projects, mainly in Europe. The subject of the research are modern electrical engineering materials such as photovoltaic cells, magnetic materials, fuel cells, composite materials, electrotechnical ceramics, powder technologies, piezoelectric materials, electrical insulating mass for special applications, electrical insulating varnishes and enamels, nanotechnology, and more. Researches of new types of contacts shapes for circuir-breaker vacuum chambers. Medium voltage superconductive short-circuit current limiter for electrical grids. Polymer solar cell 38

39 Activity 4: Production of insulation materials in our factory. ZDIII pilot plant factory is a division of. Factory was founded on the 1st of January Technologies of various electroinsulating products have been implemented there, consisting mainly in processing of glass fibre impregnated with epoxide binder by coiling, braiding, setting, vacuum saturation and press moulding. Over all the years, the existing technologies have continually been improved and updated as well as new technologies have been implemented.in 1995 the production of composite line insulators was started for applications on 15, 24, 36, 110 and 220 kv lines. The products, due to their moderate price and high quality, have been met with acceptance on the market. Selected products from our factory. View of the main page of 39

40 We invite you to our Web site lub 40

41 Thank you