In the lab, in the field or anywhere you need it

Size: px
Start display at page:

Download "In the lab, in the field or anywhere you need it"

Transcription

1 PortablepHWater Quality Meter D-70/ES-70/OM-70 Series In the lab, in the field or anywhere you need it Industry First The casing is made from shock resistant and extremely durable polycarbonate resin. With high chemical resistance it is ideal for harsh environments. According to our research as of June Laboratory use capability The optional electrode stand offers excellent manoeuvrability, allowing the electrode to be moved up and down, and from left to right, easily with one hand. Easy-to-view large display shows two measurement items simultaneously The measurement values are easily visible on a display that is about 40% larger than those of our conventional products. Two measurement values can be displayed on a single screen. *Models compatible with two item measurement: D-73, 74, 7 Chemical resistant The polycarbonate resin casing is extremely chemicalresistant*, so can be cleaned using alcohol. *Resistant to alcohol, weak acid, bases and oil. Various data processing The built-in data memory can store 1000 items, and connecting to a computer allows measurement data to be collected. Output to a GLP/GMP-compatible printer is also possible. *An optional cable is necessary to connect to a computer. The software can be downloaded after user registration. *The D-71 does not have computer and printer connectivity. Backlit LCD model Basic model D-7 D-74 D-73 D-72 CH.2 ph ORP DO CH.2 ph ORP COND RESI SAL TDS Accessories included : Instruction Manual/Quick Manual/2 pcs Batteries CH.2 ph ORP ION ph ORP ION ph ORP D-71 ph

2 Backlit LCD 2-channel measurement Waterproof and dustproof (IP67 rated) connection compatible Printer output compatible Security function Shock and chemical (printer sold separately) resistant body case Data storage software availiable as a free download for registered users. One hand operation Slim body fits in your hand. Only three basic operation buttons for one-hand operability. Shock-resistant Polycarbonate resin* used in automobiles and mobile phones has been adopted to enhance shock resistance. Visible LCD in dark places Backlight (except D-71) allows reading of measurement values even in the dark. image Waterproof and dustproof Extended operation Easy to carry IP67 rated waterproof and dustproof casing. *IP67: Fully waterproof for approximately 30 min in 1 metre of water. Uses about 10% of the power compared to conventional meters. With up to 1000 hrs of use*, long periods of field work are possible. *D-71/D-72 The compact and ergonomic design is easy to carry and includes a cable winding function for the optional electrode hook attachment. ES-71 COND RESI SAL TDS Dissolved Oxygen OM-71 DO * Select from the following: 2 m cable (OM-71-2) 10 m cable (OM-71-10) Laboratory (OM-71-L1) (BOD measurement) Common ph [D-70 series] [D-74/ES-71] Dissolved Oxygen [D-7/OM-71] LAQUAact boasts a variety of safety and other useful functions to assist with measurements and data processing. For details, see page 16 of the specifications. Interval measurement function (except D-71) Sample number setting function Clock function and auto power-off function Usable with AAA alkaline batteries, Ni-MH batteries, or AC adapter Automatic calibration and calibration interval alarm function Usable with both -point calibration and USA/NIST standard solutions Electrical resistivity/total dissolved solids/salt content conversion functions Automatic range switching, automatic temperature conversion, and unit switching functions Temperature compensation, atmospheric pressure calibration and salt concentration calibration functions Oxygen concentration and saturated oxygen concentration measurement functions

3 Electrodes/Accessories For / Combination (3-in-1) ph electrode ISFET ph electrode Combination ph electrode Glass ph electrode Reference electrode Temperature electrode ORP electrode ph Electrode when completely immersed. Description Model Temp. range ( ) ph range Plastic body Standard ToupH Sleeve ToupH Long ToupH Micro ToupH Sleeve For measurement of low-conductivity water and non-aqueous solvents Needle type For Tap water For Hydrofluoric acid sample For Strong alkali sample Needle type ISFET Flat type ISFET Needle type ISFET( D) sensor Flat type ISFET( D) sensor For very slender test tubes Flat type Standard type For measurement of low-conductivity water and non-aqueous solvents. Standard type Double-junciton type For temperature compensation and measurement Water proof Platinum 3-in-1 type * See pages 18 and 19 for the application guide for each electrode. Electrode D D D D D D D D D D D D D C C 1066A-10C 1076A-10C 2060A-10T -10T T D Electrode electrode Cell constant m -1 (cm -1 ) Model Range m -1 (cm -1 ) 10 (0.1) 31-10D 10 μs1 S 0.1 μs10 ms Immersion type 100 (1) 100 (1) 1000 (10) 10 (0.1) D 32-10D 33-10D D 0.1 ms10 S 1 μs100 ms 0.1 ms10 S 1 μs100 ms 1 ms100 S 10 μs1 S 10 μs1 S 0.1 μs10 ms Flow type 100 (1) D 0.1 ms10 S 1 μs100 ms 1000 (10) C 1 ms100 S 10 μs1 S 1000 (10) C 1m S10 S 10 μs100 ms Minimum Volume (ml) Temp. range ( ) Ion Electrode Electrode name Sodium ion electrode Cyanide ion electrode Chloride ion electrode Chloride ion electrode (Combination type)* Sulfide ion electrode Iodide ion electrode Bromide ion electrode Copper ion electrode Cadmium ion electrode Lead ion electrode Thiocyanate ion electrode Fluoride ion electrode Fluoride ion electrode (Combination type)* Silver ion electrode Nitrate ion electrode Nitrate ion electrode (Combination type)* Potassium ion electrode Potassium ion electrode (Combination type)* Calcium ion electrode Calcium ion electrode (Combination type)* Ammonia electrode (Combination type)* Model 1A-10C C C C C C C C C C C C C C C C C C C C 002A-10C All ion electrodes (except combination electrodes) require a sensor holder for attaching to the electrode stand. Please be aware of the hindering ion and ph range interference of ion electrodes. *D-73 connects combination type ion electrodes only. Measuring range ,000 mg/l Na 0.032,600 mg/l CN _ 0.43,000 mg/l CI _ 0.43,000 mg/l CI _ 0.332,000 mg/l S 2_ ,000 mg/l I _ 0.880,000 mg/l Br _ 0.066,400 mg/l Cu ,000 mg/l Cd 2 220,000 mg/l Pb 2 0.6,800 mg/l SCN _ ,000 mg/l F _ ,000 mg/l F _ ,000 mg/l Ag _ ,000 mg/l NO3 _ ,000 mg/l NO ,000 mg/l K ,000 mg/l K 0.440,080 mg/l Ca ,080 mg/l Ca ,000 mg/l NH3 Applicable reference electrode Interfering ion influence A K Li =10 NH4 =20 Ca 2 =00 S 2 MnO4 =N/A l _ =0.1 S2O3 2_ = S2O3 2_ S 2_ l _ Ag Hg 2 =N/A SCN =0.3 MnO4 = Br _ =0.03 NO3F HCO3 SO4 2_ PO4 2_ =1, A 2060A CN _ =N/A S2O3 2_ =10 l _ F _ Cl _ PO4 2_ SO4 2_ =1,000 _ MnO4 S 2_ CN _ =N/A S2O3 2 =10 NO2 =100 Br _ =1, S2O3 2_ l _ S 2_ CN =N/A MnO4 =1 Cl _ PO4 2_ =100 F NO3 SO4 2_ =1, A Fe 2+ =0.1 Ni 2+ Na =1,000 Cu 2+ Hg 2+ Ag + =N/A Pb 2+ =0.1 Fe 3+ =1 Cr 3+ Fe 2+ =100 Ni 2+ =1,000 Cu 2+ Hg 2+ S 2_ Ag + =N/A Fe 3+ =0.01 Cr 3+ =1 Cd 2+ =10 Ni 2+ Mg 2+ Zn 2+ =100 NH4 + K + =1, A CN _ l _ S 2_ S2O3 2_ =N/A Br _ =1 Cl _ =100 Possible interference when multiply-charged ion (ex. Al 3 Fe 3 )coexisted and foamed the complex. Hg 2 =N/A Cu 2 Cd 2 Pb 2 Zn 2 Mg 2 Ca 2 Na K =Over 1000 _ ClO4 =0.03 l _ =0.1 Br =2 NO2 =3 Cl _ =40 F _ = A CH3COO _ =300 SO4 2_ =Over 1000 Rb =0.4 Cs =3 NH4 =70 Li Na Mg 2 Ca 2 Sr 2 Ba 2 =Over 1000 Fe 3 =0.1 Fe 2 Zn 2 =1 Sr 2 =0 Ni 2 Cu 2 =70 Co 2 =30 Mn 2 =00 Mg 2 =1,000 Na K Ba 2 NH4 =Over 1, The selection coefficient is a ratio of the limit concentration of coexisting ions (mol/l) to the ion concentration to be measured (mol/l); A value of 1000 means that the coexisting ions can be permitted up to 1000 times the ion measured and ''N/A'' means that chemical change occurs in the solid response membrane. Ion Electrode Tip Electrode name Chloride ion tip Fluoride ion tip Nitrate ion tip Potassium ion tip Calcium ion tip Ammonia electrode membrane (6pcs) Model membrane (NH3) DO Electrode /DO Tip Electrode Cable length Waterproof DO electrode 2m Waterproof DO electrode 10m DO electrode 1m DO tip DO tip Model 91-20D D D Specification Field immersible type Field immersible type Laboratory use Replacement electrode tip for 91 Replacement electrode tip for 920 Temp. range ( )

4 Accessories Name Printer (for GLP/GMP compliance) Printer cable Printer paper Ink ribbon AC adapter cable set. Digital simulator X-1 Digital simulator X-2 USB cable LCD protection sheet Protection cover Analog cable Serial cable Electrode hook DP-70S Electrode stand (adjustable type) FA-70S Electrode stand (adjustable type) FA-70L Electrode stand (long type) Remarks F-70 DS-70 D-70 ES-70 OM-70 Cable sold separately,plain paper 1. m 20 rolls pcs/set AC adaptor 1.8 m, cable 1 m ph, mv, ION, DO simulator (for periodic inspection of the electrode) simulator (for periodic inspection of the electrode) Cable to connect a meter and. 2 pcs/pack Protects the meter for F-70, DS-70 series Analog (alarm) output cable Cable to connect a meter and (Serial, 9 pins) With function for winding the cable With holder for D/ES/OM-70 Free-standing type. Hight 384 mm Free-standing type. Hight 4060 mm Except D-71 2 measuement model: F-74/F-74BW/D-74 3 Except F-71/F-74BW/DS-71 1 Printer (for GLP/ GMP compliance) Digital simulator FA-70L Electrode stand (long type) ph Standard Solution SET Standard Solutions Name Oxalate standard solution Phthalate standard solution Phosphate standard equimolal solution Borate standard solution Carbonate standard solution Powder for ORP standard solution Powder for ORP standard solution Internal Solution for Reference Electrode Internal solution for NH3 electrodes Type 101-S Specification ph49 Standard Solution ph7 Standard Solution Internal Solution for Reference Electrode 00 ml 00 ml 00 ml 00 ml 00 ml For 20 ml (10 packets per set) For 20 ml (10 packets per set) 3.33 mol/l KCl Remarks 20 ml 00 ml 20 ml ph 1.68 (2 ) ph 4.01 (2 ) ph 6.86 (2 ) ph 9.18 (2 ) ph (2 ) 2 89 mv 2 28 mv 20 ml 20 ml Electrode Cleaning Solution For removing inorganic sample residues from glass electrodes, and for cleaning liquid junctions Name Electrode cleaning solution Name Electrode cleaning solution Type 220 Type 20 Volume (ml) 0 x 2 pcs Volume (ml) For removing protein containing sample residues from glass electrodes, and for cleaning liquid junctions For D (ph electrode for tap water or low conductivity sample) Name Type Volume (ml) Solution A 30 ml Electrode cleaning solution Solution B 100 ml Dimension Unit: mm F-70 Series / DS-70 Series D-70 Series / ES-70 Series / OM-70 Series 174 Long type electrode stand FA-70L Electrode stand FA-70S Electrode stand DP-70S

5 ph mv (ORP) Temperature ION Salinity Resistivity TDS Input/ output Data F-70/ DS-70 series specifications Measurement range Display range Auto range select ph calibration point check Alarm limit of calibration Periodical check Measurement range Measurement range Measurement range Periodical check Calibration curve point Addition method measurement Measurement range (Display range) Change unit Distilled water temperature conversion Periodical check JP/EP/USP/CP Pharmaceutical water aplication Measurement range (Display range) Salt concentration calibration Measurement range (Display range) Measurement range (Display range) Input (number of channels) USB peripherals (Communication with ) *1 USB host (USB memory) RS-232C (Printer/) Analog out put Memory number Interval memory input Data search Display Dual component display Display Multilanguage display Navigation function User guide Graph display Printer connectivity (GLP/GMP) Custom printing function Temperature compensation (Auto/manual) Function AutoHold function AutoHold setting Stability function (ph/ion) Register operator Security (password) Version up function Ambient temperature Power Demensions Power consumption Mass of main unit *1 USB cable sold separately. Software can be download by web registration. F-71 F-72 F-73 F-74 F-74BW DS-71 DS-72 ph ph ±0.00 ph±1 digit Custom LCD Approx. 0.7 VA Approx. 00 g Galass electorode method ph ph /0.001 ph ±0.001 ph±1 digit ± mv 0.1 mv ±0.1 mv±1 digit ( ) 0.1 ±0.1 ±1 digit Ion electrode method 0.00 μg/l999 g/lmol/l Valid numbers 3 digits ±0.%F.S.±1 digit Color graphic LCD with capacitive Touch Panel Japanese/English/Chinese/Korean ph ph ±0.00 ph±1 digit 2 AC bipolar method Cell constant 100 m ms/m19.99 S/m Cell constant 10 m μs/m1.999 S/m Cell constant 1000 m ms/m199.9 S/m 0.0% of full scale ±0.%F.S.±1 digit PPT (0.000%8.000%) 0.01 PPT (0.001% Cell constant 100 m Ωm199.9 kωm Cell constant 10 m Ωm1.999 MΩm Cell constant 1000 m Ωm19.99 kωm 0.0% F.S. ±0.%F.S.±1 digit 0.01 mg/l1000 g/l 0.01 mg/l100 g/l 0.01 mg/l AC adaptor V 0/60 Hz 170 (W) 174 (D) 73 (H)mm (Excluding electrode stand and AC adaptor) Approx. 9.8 VA Approx. 700 g 999 Custom LCD Approx. 0.7 VA Approx. 00 g mg/l1000 g/l Color graphic LCD with capacitive Touch Panel Japanese/English/ Chinese/Korean Approx. 9.8 VA Approx. 700 g

6 ph mv (ORP) Temperature ION Salinity Resistivity TDS Dissolved Oxygen Saturated Oxygen Oxygen concentration Display Function D-70/ ES-70/ OM-70 series specifications Measuring range Display range Auto calibration ( points)/calibration record Standard solution Auto-detect USA/NIST selectable Calibration interval alarm Absolute/relative selectable Calibration function points calibration/calibration record Change unit (S/m,S/cm) Auto temperature conversion (2 ) Calibration function Temperature compensation Salinity concentration correction (040PPT) Air pressure correction connectivity 3 Printer connectivity (GLP/GMP) Temperature compensation (Auto/manual) Auto Hold function Data memory number Interval memory input Clock function Auto power off/battery Level Indicator Dustproof and waterproof standard Operating ambient temperature/humidity Power Current consumption Battery life 4 Dimensions Weight (without batteries and electrode) D-71 D-72 D-73 D-74 D-7 ES-71 OM-71 Glass electrode method ph Flashes when outside the measurement range 0.01 ph ±0.01 ph±1digit mv Flashes when outside the measurement range 1 mv ±1 mv±1 digit ( ) Flashes when outside the measurement range 0.1 ±0.1 ±1digit on electrode method 0.00 μg/l999 g/l 3-digit valid numbers ±0.% F.S.±1 digit 1 Cell constant 100 m -1 : ms/m20.00 S/m, Cell constant 10 m -1 : 0.0 μs/m2.000 S/m, Cell constant 1000 m -1 : 0.00 ms/m200.0 S/m 2 Cell constant 100 m -1 : 0.00 Ωm200.0 kωm, Cell constant 10 m -1 : 0.0 Ωm2.000 MΩm, Cell constant 1000 m -1 : Ωm20.00 kωm 3 RS-232C cable ( ) and software is required. Software can be download by web registration. If you need to connect to the USB, the commercially available (RS232C to USB) adapter is required. Please purchase according to the specifications of the (Operating system USB Specification, etc.). HORIBA will not guarantee the adapter operation 4 Battery life will be shorter when using optional accessories and LCD backlight is activated. 2 AC bipolar method 0.0 μs/m200.0 S/m 1 0.0%F.S. ±0.% F.S.±1 digit 0.00%4.00% (0.0PPT40.0PPT) 0.01%/0.1 PPT Ωm2.000 MΩm 2 0.0%F.S. ±0.%F.S.±1 digit 0.01 mg/l100 g/l 0.01 mg/l 2 AC bipolar method 0.0 μs/m200.0 S/m 1 0.0%F.S. ±0.% F.S.±1 digit 0.00%4.00% (0.0PPT40.0PPT) 0.01%/0.1 PPT Ωm2.000 MΩm 2 0.0%F.S. ±0.%F.S.±1 digit 0.01 mg/l100 g/l 0.01 mg/l Membrane galvanic cell Membrane galvanic cell mg/l mg/l mg/l 0.01 mg/l ±0.1 mg/l±1 digit ±0.1 mg/l±1 digit Membrane galvanic cell Membrane galvanic cell % % 0.1% 0.1% Membrane galvanic cell Membrane galvanic cell % % 0.1% 0.1% Custom LCD Custom LCD with backlight 1000 IP67 0 to 4, 80% or less in relative humidity (no condensation) LR03/AAA alkaline batteries or AAA Ni-H rechargeable batteries 2, AC adapter 100 V to 240 V 0/60 Hz (option) Less than 1 ma Less than 1 ma Less than 2 ma Less than ma Less than 2 ma Less than ma Less than 2 ma Approx. 67 (80) 28 (42) 170 mm (The figures in parentheses are maximum thicknesses.) Approx. 270 g Approx. 270 g Approx. 28 g Approx. 28 g Approx. 28 g Approx. 270 g Approx. 270 g

7 ph Electrode Selection Guide Specification Applicable temperature range ( ) Diameter (mm) Position of liquid junction (approx. mm) Length (mm) PLASTIC D STANDARD ToupH D LONG ToupH D in-1 ELECTRODES (ToupH) MICRO ToupH SLEEVE ToupH For TAP D D D HF D ph-sample Conditions Aqueous Solution Solid/Semisolid Normal (over 100 ms/m) Low (approx ms/m) Very low (approx. 10 ms/m) High (approx. S/m) Strong alkaline (ph 10-) Strong acidity (ph 0-2) Except HF sample Quick heat change (within 0 C) High viscosity (approx. Pa S) Containing non-aqueous solvent Suspension Inside Surface ph-sample Conditions Microtube/plate (> 0 µl) Sample Containers NMR tube Ampule φ mm > φ4 mm > φ4 mm Micro container (> 2 ml) Tube :13 mm, L:100 ~ 10 mm Beaker 10 ml1 L Large container (> 1 L) Petri dish Droplet ph-typical Samples Water Chemical reagent/solvent Pharmaceutical/ biology sample Food Beverage/ seasoning Cosmetic/ lotion Pure/ion-exchange water (approx. 0.1mS/m) Distilled water (approx. 0. ms/m) Tap/drinking water (approx. 10 ms/m) Surface water Pharmaceutical water Enviromental water/acid rain Caustic/strong acid (Except HF sample) Hydrofluoric acid Organic solvent KCl-reactive solution Surfactant Water-based paint Dye/coloring agent Protein-containing sample Medicinal preparation Enzyme solution Tris buffer Suspension Agar medium Jam Meat/fish Fruit/vegetable Dough Honey Cheese/butter Yogurt Beer Milk Carbonated drink/juice/sauce/soy sauce Mayonnaise/ketchup Beauty cream/mascara Gel/soap/shampoo Hairdye lotion Emulsified liquid

8 ALKALI D ISFET ELECTRODES NEEDLE FLAT ISFET ISFET D D RecommendedCan be measuredprohibited or risk of damage Representative sample names are shown in the table, therefore they may not apply to all cases.a reference electrode is necessary for a glass electrode. 3-in-1 ELECTRODES COMBINATION ELECTRODES GLASS ELECTRODES REFERENCE ELECTRODES SLEEVE NON- SLENDER NON- AQUEOUS NEEDLE TEST TUBE FLAT STANDARD AQUEOUS STANDARD DOUBLE D D D C C 1066A-10C 1076A-10C 2060A-10T -10T (inside) (inside) (inside) (inside) (inside) (inside) (inside) (surface) (surface) (surface) (surface) (surface) (surface) (surface)

9 Wolf Laboratories Limited Tel: Fax: Use the above details to contact us if this literature doesn't answer all your questions. Pricing on any accessories shown can be found by keying the part number into the search box on our website. The specifications listed in this brochure are subject to change by the manufacturer and therefore cannot be guaranteed to be correct. If there are aspects of the specification that must be guaranteed, please provide these to our sales team so that details can be confirmed.