Energy and Water Savings

Size: px
Start display at page:

Download "Energy and Water Savings"

Transcription

1 Join the Green Team Since 1998 Energy and Water Savings 10%+ Energy Savings 20% Water Savings Fully Automated Skid-Mount Particle Precipitator Water Filtration System Full Service Control of - Total Dissolved Solids - Total Suspended Solids - Conductivity TYPICAL APPLICATIONS Chillers / Cooling Towers Boilers Plate & Frame Exchangers Tube Bundle Heat Exchangers Reverse Osmosis Humidifiers Air Compressors Fountains ELECTROCELL Systems 3320 Nazareth Road, Easton, Pennsylvania U.S.A. Ph: Fax: info@electrocellsystems.com Web Site: 10/14

2 ELECTROCELL Systems Approach to Water and Energy Savings ELECTROCELL s Water/Energy Savings Approach To provide a healthy, clean condenser/evaporative system is our primary goal. exchanger will save water and energy, as well as extend equipment life cycles. A clean heat ELECTROCELL concentrates on total suspended solids removal and control of total dissolved solids Our technology improves thermal transfer in the condenser and evaporative heat exchangers. This will utilize each chiller to its optimal efficiency thereby saving energy. In turn, the cooling towers are a slave to the chiller heat load and abilities to transfer temperature through their exchangers. This is where water savings are achieved. By removing suspended solids and controlling dissolved solids ELECTROCELL has been successful in reducing large percentages of make-up water to the cooling towers and energy needed to operate chillers. Unlike most side-stream filters ELECTROCELL s system uses no media and requires no backwash or continuous maintenance. ELECTROCELL s philosophy is to concentrate on evaporation rates rather than trying to extend bleed cycles. Make-up water to your cooling towers is divided into evaporation (75%) and bleed (25%). Bleed cycles are a necessary evil to rid the system of dissolved minerals (scale). Pushing or extending bleed cycles is risky business and will cost energy in the long run. Remember, bleed makes up only 25% of a towers usage in most cases. ELECTROCELL removes 95% of suspended solids down to one micron, which greatly increases the condenser water s thermal transfer rate, and also manages dissolved solids that may produce fouling (scale). ELECTROCELL monitors chillers approach temperatures which will verify our system s effectiveness in keeping exchanger tubes clean. ELECTROCELL monitors and logs monthly make-up and bleed usages. ELECTROCELL concentrates on evaporation rate needed 75% of your system s usage. ELECTROCELL s water savings have never been the result of increased bleed cycles Our success is in direct proportion to the improvement in equipment efficiencies. ELECTROCELL has been servicing Fortune 500 companies since ROI is between two and three years. Typical installation 10-15% energy savings 20+% make-up water savings Our system is a central treatment skid with PLC that requires a simple installation (2-3 days). Condenser Loop One PVC Inlet One PVC Outlet One PVC Drain One 20A Circuit Evap Loop One PVC Inlet One PVC Outlet One PVC Drain One 20A Circuit Pipe sizes will vary with tonnage capacity ELECTROCELL can work with existing chemical suppliers to enhance your chemical program. 1

3 2

4 3

5 4

6 ELECTROCELL Systems 4200-ton Chiller System Boiler Systems 1500-ton Chiller System Closed Loop Filter 5

7 New Jersey Pharmaceutical Application North & South Chiller Plants Total System: 15,000-tons plus 6

8 7

9 ELECTROCELL Systems 8

10 Fast, easy installation Condenser Open Loop Chilled Water Closed Loop Piping: Inlet: Outlet: Drain: One Sch-80 PVC One Sch-80 PVC One Sch-80 PVC Inlet: Outlet: Drain: One Sch-80 PVC One Sch-80 PVC One Sch-80 PVC Option: Mild steel or copper piping may be used NOTE: Piping and skid must be insulated Electrical: One 3-Phase 20-Amp Circuit Pipe sizes will vary with tonnage capacity 9

11 Ec-3000 Particle Precipitator Water Filtration Skid ELECTROCELL s Particle Precipitator is a side-stream technology applied to open/closed loops in chilled water systems. Pipe sizes will vary with tonnage capacity. We typically suggest Sch-80 PVC for the inlet, outlet and drain. 10

12 11

13 Advantages of an ELECTROCELL System Over 30 years of HVAC experience with patented technology Advantages to consider: Enhances current chemical program Documented 20-25% reduction in condenser loop make up water Documented increased energy efficiency due to more efficient thermo transfer Increased life cycles on equipment and reduction in maintenance costs Fast ROI months with installation Startup and 1st year service included in cost Monthly water chemistry testing Monitoring of water/energy use and equipment efficiencies (chillers and cooling towers) DDC monitoring of system with alarms Two-year warranty on all ELECTROCELL equipment provided Ongoing continuous new technology available At customer s request an ELECTROCELL local licensed representative will conduct a no cost survey of your water treatment mechanical equipment. If our technology is a fit for your building s water treatment needs we will prepare a proposal for your consideration that will include both cost and projected savings to be realized. ELECTROCELL s proposal will be a turn-key submission that includes design, manufacturing, installation, start-up, training and one year service. Our system is a totally automated skid-mount side-stream high tech water treatment system that addresses total dissolved and suspended solids. Each system comes with a touch screen PLC that can be interfaced with your building automation system. The PLC provides you with all the necessary information pertaining to your water treatment system such as conductivity, flow totalizers on filter, bleed and make-up, evaporation rates and alarms - control of TDS and TSS. ELECTROCELL works with your local existing chemical company to assure peak performance in your water treatment system. Each system is custom designed and proudly built in the United States. 12

14 Join the Green Team 3320 Nazareth Road Easton, Pennsylvania Tel: / Fax: info@electrocellsystems.com Web: