Planning for Water Reuse in Northeastern Illinois (and other places where most people think there is an abundant water supply)

Size: px
Start display at page:

Download "Planning for Water Reuse in Northeastern Illinois (and other places where most people think there is an abundant water supply)"

Transcription

1 Planning for Water Reuse in Northeastern Illinois (and other places where most people think there is an abundant water supply) Illinois Waste Management and Research Center March 12, 2008 Paul Anderson, CAEE Department, IIT 1

2 Acknowledgments Partners Illinois Institute of Technology Illinois Waste Management and Research Center Chicago Metropolitan Agency for Planning Sponsors US EPA Science to Achieve Results Program Illinois Waste Management and Research Center Who does all the work Sachin Pradhan Yi Meng Shihui Luo Feng Huang 2

3 Overview Parts of NE Illinois are running out of water Water reuse is part of the solution Industries have hydrologic footprints Issues that affect reuse planning An integrated reuse system 3

4 NE Illinois: Growing demand for water 2,000 Projected water use (mgd) 1,800 1,600 1,400 Baseline Scenario Conservation Scenario NIPC 1, Dziegielewski et al. (2005) Year 4

5 We don t t use water very efficiently Toilet (28%) Kitchen (3%) Laundry & cleaning (14%) Shower & bath (22%) Outdoor (33%) Domestic water use (USEPA, 2006) 5

6 NE Illinois: Limited water sources Minimum flow requirements Inland Surface Water 3% Aquifers 11% Unknown resources Falling water table Limited by Supreme Court decree Lake Michigan 86% Northeastern Illinois regional non-cooling water source allocation (NIPC, 2001) 6

7 The Illinois Diversion Lake Michigan 54% 2 WPPs Users Reuse N.B. Chicago River 16% 30% Combined Sewer System 7 WWTPs Chicago Sanitary & Ship Canal, Cal-Sag Channel Lockport Mississippi River 7

8 Water reuse priorities Industrial Process/cooling Commercial/Domestic Car wash Toilet flush Firefighting Irrigation Groundwater recharge Potable water Low Quality High High Priority Low 8

9 Industrial hydrologic footprints Measure of industry interaction with water Conventional direct water use Evaporative loss associated with electricity use Stormwater runoff from industry property Supply chain direct water use Supply chain evaporative loss with electricity 9

10 Estimating hydrologic footprints in Chicago Consider 50 largest volume water dischargers Supply chain data from eiolca.net Data normalized to economic activity (gal/$) 10

11 Water & electricity use for 31 Direct electricty use (MkWh) Mid-water & electricity use industry sectors High water & electricity use Low water & electricity use Water evaporated with electricity use (10 9 gallons) Direct water use (10 9 gallons) 11

12 Supply chain water & electricity use Electricity (MkWh) Supply chain dominated by less than 60 unique SIC codes Water evaporated with electricity (10 9 gallons) Direct water use (10 9 gallons) 12

13 Who makes up the supply chain? Blast furnaces and steel mills Industrial inorganic and organic chemicals Paper and paperboard mills Petroleum refining Pulp mills Nitrogenous and phosphatic fertilizers Primary aluminum Plastics materials and resins 13

14 Hydrologic footprints for four SIC codes 2066 Chocolate & Cocoa Products SIC code Dog & Cat Food Meat Packing 2046 Wet Corn Milling Industry direct Industry electricity Supply chain electricity Supply chain direct On-site stormwater 14

15 Hydrologic footprint summary Indirect use (stormwater, electricity) is small Direct use (industry or supply chain) dominates Supply chains are often important Supply chains dominated by a few industries 10% have relatively big footprints (gal/$) What issues affect water reuse? 15

16 Water reuse: Barriers & Incentives Risk Policy Economics Regulations Technology Water Source Wastewater Treatment Users 16

17 Water reuse regulations Federal There are no water reuse regulations Guidelines for Water Reuse (USEPA, 2004) States (2004 data) 25 states have regulations 16 states have guidelines 9 states without regulations or guidelines Illinois regulations address land application 17

18 Water reuse risks Ecosystem risks Chemical contaminants of concern Nutrients Human health risks Pathogenic organisms Bacteria, viruses, protozoa Chemical contaminants of concern Pharmaceuticals Pesticides, herbicides Disinfection by-products 18

19 there have not been any confirmed cases of infectious disease resulting from the use of properly treated reclaimed water in the U.S. USEPA (2004) Are there unconfirmed cases? What about non-infectious disease? How long does it take to see effects? What about incidental reuse? What about ecosystem risks? 19

20 Is wastewater reuse economical? Objective: Minimize cost Constraints: Demand Mass balance Capacity Water withdrawal Water quality 20

21 Pipeline costs dominate Pumping CC 1% Pumping O&M 5% Disinfection O&M 3% Revenue loss <1% Pipeline CC 91% 21

22 Costs have a spatial relationship Volume demand increases with distance III II I 22

23 Costs depend on flow & distance 10 Supply cost Volume Qdemand 23

24 Costs depend on flow & distance 10 Supply cost Q 24

25 Costs depend on flow & distance 10 Supply cost Q 25

26 Costs depend on flow & distance 10 Increasing the distance increases the cost Supply cost 5 Increasing the flow decreases the cost The minimum cost Q 26

27 A case study for industry near the Kirie WRP 27

28 Kirie case study 28 Significant Industrial Users Metal finishing: 16 Electroplating: 4 Others: 8 Total water discharge: 1.09 MGD Assume 50% treated effluent use Supply effluent 12 months/year 6 months/year additional chlorination 28

29 Kirie case study parameters Interests rate: 6% 5%~10% Utility service life: 40 years 25~40 years Amortization period: 40 years 25~40 years Pipeline installation unit cost: 75 US$/feet 75 ~ 200 US$/feet 29

30 Kirie case study Zone 1 Zone 2 Zone 3 30

31 Kirie case study Zone 1 31

32 Kirie case study Zones 1 & 2 32

33 Kirie case study Zones 1, 2 & 3 33

34 12 Cost depends on volume & distance (i = 6%, τ = 40 years, Pipeline US$75/feet) Supply cost (2006US$/1,000 gallons) L = 5.6 miles L = 8.2 miles L = 13.4 miles Elk Grove Village water Chicago municipal water Flow rate (MGD) 34

35 Chicago reuse study summary Pipeline installation costs dominate Spatial relationships affect supply cost Reuse can be cost effective Chicago is an unusual case study Municipal water is very cheap Reuse offers no economic incentive to MWRDGC Chicago s s successful water conservation efforts 35

36 What about the western suburbs? Recent drought Municipal water costs are higher Groundwater supplies uncertain Surface water up to 35% treated effluent 36

37 New issues in the suburbs Industrial clusters are limited Distribution over longer distances Consider non-industrial users Park district, golf course, forest preserve Limited seasonal demand Potential increased exposure 37

38 Integrated water reuse planning for the suburbs Inventory available land considering: IEPA land application regulations Distance Relationship to potential co-users Model fate and transport Soil, groundwater, surface water Process design and operation 38

39 Are there other reuse incentives? Greatest cost: Distribution system Is there another benefit? Once you install a secondary distribution system, is there another use? 39

40 Geothermal heat pumps the most energy efficient, environmentally clean, and cost-effective space conditioning systems available. (USEPA, 1993) Benefits (USDOE, 1998): Less energy consumption Lower operating costs Reduced carbon emissions 40

41 Average monthly temperatures (2002) O'Hare Field 0 Stickney Treatment Plant Effluent -5 Jan-02 Feb-02 Mar-02 Apr-02 May-02 Jun-02 Jul-02 Aug-02 Sep-02 Oct-02 Nov-02 Dec Temperature (C)

42 Effluent as a heat source/sink Growing interest in water-source heat pumps Illinois Clean Energy Community Foundation 200 geothermal demonstration systems Space conditioning and hot water supply Payback < 10 years Benefits of working with effluent Higher temperature implies higher efficiency Avoid drilling to install ground loops 42

43 Domestic geothermal heat pump Ground loop represents about 60% of initial costs USDOE (1998) 43

44 Dual-purpose distribution system Integrated infrastructure Non-potable water supply Ground loop for heat pump system Issues Economics Regulations Technology Risk Policy 44

45 Summary thoughts Water reuse can help meet demand Hydrologic footprints measure efficiency Incentives & barriers for reuse Soft: Technology, policy, regulations Hard: Public perceptions, economics Water reuse can be economical Integrated planning for multiple uses Consider water & energy 45