1 Laboratory Products Guide

2 With Great Products, Come Great Results Products HANNA offers an extensive range of process instruments and laboratory equipment to monitor water quality in a variety of applications. The HANNA Difference 24/7 Access HANNA s full catalog of instrumentation is available online at Local Customer Support After you ve made your investment, you should never feel uncertain about the support or technical service you will receive. It is our philosophy that the best way to support our customers is to be close to them. HANNA has over 30 of ces around the world to provide our customers with dedicated service that s just around the corner. Aggressive Warranty All HANNA products are covered by a parts and labor warranty, ranging from six months to 3 years. Competitive Pricing By developing and manufacturing every product in-house, HANNA pricing is a major source of envy for our competitors. We are reputed to offer the best value on the market. Reliable Products Over three decades of manufacturing to ISO 9001:2000 standards is re ected in every aspect of your instrument.

3 Table of Content Titrators pages 3-6 ph Meters pages 7-10 Turbidity & Chlorine Meters pages Multiparameter Meters pages Dissolved Oxygen pages Refractometers pages Conductivity Meters pages 21 Temperature pages 22 Electrodes pages ISE s pages Solutions pages Accessories pages 29 Technical Support pages 30

4 Titrators HI 902C Complete Analytical Multiparameter Titration System The HI902C Titrator supports up to 100 methods and can perform acid/base, potentiometric, ORP, complexometric, precipitation and back titrations. The user also has the option to connect ph, ORP or ISE electrodes. 2 analog boards, 2 pumps and 2 stirrers Available w/1 or 2 Analog Board Available w/1 or 2 Pumps Available w/1 or 2 Stirrer HI 901 Complete Analytical Multiparameter Titration System Large 7.5 (320 x 240 pixel) black and white LCD User customized reports can be printed, saved on disk transfer to PC via RS232 interface 40,000 step piston dosing pump for enhanced accuracy 3 USB port for PC connectivity Can perform multiple in ection points titrations Linked titration methods 4 working modes: potentiometric, titrator, ph meter and ISE meter Support up to 100 methods: standard or user de ned. Common methods performed include: ph, Acidity, Ascorbic Acid (Vitamin C), Fluoride, NaCl, Chlorine, SO 2, Calcium, Alkalinity, Calcium, Sulfate and much more.

5 Titrators HI 903 Karl Fischer Titration System Application support available! HI 904 Coulometric Karl Fischer Titration System Perfect for testing any parameter, HANNA s line of titrators combine an ultra-high precision titrant delivery system with optically regulated magnetic stirring, sophisticated endpoint determination, dynamic dosing and background drift correction algorithms. Built-in magnetic stirrer Field upgradable software via USB HI 904 Coulometric Karl Fischer Titration System measures 000.5% to 100% water content with precise dosing system capable of delivering as little as L of titrant with a single dose. HI 903 Karl Fischer Titration System measures 100% to 100 ppm water content. Combines an ultra-high precision titrant delivery system with optically regulated magnetic stirring, sophisticated endpoint determination, dynamic dosing and background drift correction algorithm Perfect for Food and Beverage Pharmaceuticals Cosmetics Chemical and Petrol Manufacturing Solvents 4

6 Titrators HI Total Titratable Alkalinity Titrator with ph and temperature measurement capability Affordable for all lab budgets! User-friendly interface Easy to use Log on demand up to 100 samples (50 for ph measurement; 50 for titration results) GLP feature, to view last calibration data for ph electrode and pump PC interface via USB connection HI Total Titratable Acidity Titrator with ph and temperature measurement capability User-friendly interface Easy to use Log on demand up to 100 samples (50 for ph measurement; 50 for titration results) GLP feature, to view last calibration data for ph electrode and pump PC interface via USB connection Peristaltic Pump Both the HI and HI feature a precision, peristaltic based titrant delivery system. Titrant only makes direct contact with the titrant tubing and not the pump interior virtually eliminating titrant contamination and ensuring a long pump operating life. 5

7 Titrators HI Automatic Mini Titrator and ph Meter for titratable acidity determination in fruit juices Methodology used is based on the AOAC International accepted method for acidity determination Eliminates subjective factors Log on demand up to 100 samples (50) ph measurement; (50) titration GLP feature to view last calibration data for ph electrode and pump Can measure in % of Citric, Malic and Tartaric acid Affordable for all lab budgets! All-in-One: Fruit Juice Titrator, ph Meter, ph Electrode and Magnetic Stirrer in one package HI Mini Titration System and ph Meter for titratable acid in dairy products Accurate and easy to use ph and lactic acid of your dairy and cheese Automatic temperature compensation Uses industry accepted methods Data logging The determination of total acids in dairy products is made according to a neutralization reaction; that is the reaction between the acids found in dairy products and a base. This type of reaction forms the basis of titration methods of analyzing acids. Titratable acidity is measured on a degassed sample at the end point of 8.30 ph. The results are expressed in SH, Thm D or % l.a. 6

8 ph Meters HI 4222 Research-Grade ph/ise Dual Channel Bench Meter Dual-channel 2 Price Range $ $ 1450 ph Exclusive HANNA CAL CHECK Five point calibration with standard and custom buffers ISE Direct calibration and measurement in multiple units Incremental methods: ~ Known addition ~ Known subtraction ~ Analyte addition ~ Analyte subtraction 240 x 320 dot-matrix color screen Millesimal measuring resolution Real-time graphic displays HI 4221 Research-Grade ph/orp Bench Meter ph Exclusive HANNA CAL CHECK Five point calibration with standard and custom buffers EC Extended range from S/cm to 1 S/cm 3 salinity scales: ~ Practical salinity ~ Natural sea water ~ Percent 240 x 320 dot-matrix color screen Millesimal measuring resolution Real-time graphic displays Dual-channel1 7

9 ph Meters Price Range HI 3220 ph/mv/temperature Bench Meter with Calibration Check Backlit, Graphic LCD Stability, interval and Log-on-demand logging 5 point calibration with 7 standard and 5 custom buffers Log-on-demand 200 samples Auto HOLD to freeze readings on the display GLP to view last calibration data for ph or Rel mv PC compatible via USB $ $ 750 HI 3221 ph/mv/ise/temperature Bench Meter with Calibration Check Backlit, Graphic LCD Prompts and messages on the graphic LCD Stability, interval and Log-on-demand logging 5 point calibration with 7 standard & 5 custom buffers Log-on-demand 300 samples PC compatible via USB GLP (Good Laboratory Practice) Last calibration data is stored automatically after a successful calibration. Calibration data can be easily accessed and includes calibration buffer, offset, slope and electrode condition information. Previous calibration points are shown in reverse text. 8

10 ph Meters HI 2211 ph/mv Bench Meter perfect for quality control applications Price Range $ $ 400 Extra Wide LCD (6.25 x 1.5 ) Automatic Calibration 5 Standard Buffers Simultaneous display of ph and Temperature Automatic Temperature Compensation (ATC) Extended mv Range HI 2210 ph/mv/ise/temperature Bench Meter with Calibration Check Extra Wide LCD (6.25 x 1.5 ) Automatic Calibration 5 Standard Buffers Simultaneous display of ph and Temperature Automatic Temperature Compensation (ATC) First Calibration Point Second Calibration Point Calibration Operations When entering calibration mode with the CAL button, the instrument prompts the user to immerse the electrode into the rst buffer (offset). The instrument will ask the user to con rm the rst calibration point before prompting the second point. To perform a one point calibration, press CAL after the rst point has been con rmed. After con rming the rst calibration point, the instrument prompts the user to immerse the electrode in the second buffer (slope). The instrument will ask you to con rm the reading. 9

11 ph Meters HI 9126 Portable ph/mv Meter with enhanced design Exclusive Calibration Check Electrode condition monitoring Backlit LCD Display Waterproof Multi-level LCD display Up to 7 standard buffers for calibration and 2 custom buffers User-selectable calibration time out Automatic calibration Automatic Temperature Compensation Battery % displayed on startup HI Portable ph/mv Meter with enhanced design Exclusive Calibration Check Electrode condition monitoring Backlit LCD Display Waterproof Multi-level LCD display Up to 7 standard buffers for calibration and 2 custom buffers User-selectable calibration time out Automatic calibration Automatic Temperature Compensation Battery % displayed on startup Visit to view tutorial product video CALIBRATION CHECK SYSTEM Each time ph calibration is performed, the meter internally compares the new calibration with the one previously stored. When this comparison indicates a signi cant difference, the clean message blinks on the LCD to advise the user that the ph electrode may need to be cleaned and another calibration will need to be performed. 10

12 Turbidity & Chlorine HI Turbidity & Free/Total Chlorine Bench Meter highly accurate turbidity measurement EPA 4 measuring ranges: ~ Ratio Turbidity ~ Non-Ratio Turbidity ~ Free Chlorine ~ Total Chlorine Good Laboratory Practice capabilities 2, 3, 4 or 5 point turbidity calibration Log and recall up to 200 measurements compliant HI Turbidity Bench Meter ideal for drinking water applications EPA compliant 2 measuring ranges: ~ Ratio Turbidity ~ Non-Ratio Turbidity 2, 3, 4 or 5 point turbidity calibration Good Laboratory Practice capabilities Log and recall up to 200 measurements GLP (Good Laboratory Practice) The calibration date and the calibration points are displayed in a comprehensive mode for each range. To display the GLP information, simply press CAL CHECK key. A screen with instrument serial number and with information about the calibration is displayed. For further information, press the GLP functional key. 11

13 Turbidity & Chlorine HI Turbidity & Free/Total Chlorine Portable Meter highly accurate turbidity measurement High accuracy at low ranges (below 0.05 NTU) Exclusive chlorine Cal Check calibration validation Exclusive T.I.S. Tag Identi cation System User replaceable light source 2, 3 or 4 point turbidity calibration USB and RS 232 connectivity Backlit LCD GLP capability User friendly display with guidance codes Auto shut-off Battery percentage display Continuous display of current time EPA compliant HI Turbidity Portable Meter ideal for drinking water applications High accuracy at low ranges (below 0.05 NTU) Exclusive chlorine Cal Check calibration validation Exclusive T.I.S. Tag Identi cation System User replaceable light source 2, 3 or 4 point turbidity calibration USB and RS 232 connectivity Backlit LCD GLP capability User friendly display with guidance codes Auto shut-off Battery percentage display Continuous display of current time EPA compliant 12

14 Multiparameter HI 3222 ph/mv/ise/temperature Bench Meter with 2 channel input Dual input channels Backlit, graphic LCD Exclusive Calibration Check Prompts and messages on the graphic LCD Stability, interval and log on demand logging 5 point calibration with 7 standard and 5 custom buffers Relative mv measurements Up to 400 sample memory capacity Auto HOLD to freeze readings on the display User selectable language GLP to view last calibration data for ph, Rel mv or ISE User selectable Outside Calibration Range warning User-selectable Calibration Timeout to remind when a new calibration is necessary PC interface via USB 13 Electrode Dirty/Broken and Contaminated Buffer Warnings These warnings are displayed when the offset of the electrode is not in the accepted range and calibration cannot be con rmed. This could be the result of a broken electrode, or an electrode which needs to be cleaned. Also, the buffer solution quality could have been compromised and may need to be changed.

15 Multiparameter HI 4522 ph/ise and Conductivity Bench Meter multiparameter research-grade bench meter 240 x 320 dot matrix color display Logging and graphing capabilities Stages 1, 2 and 3 USP mode ph Exclusive HANNA CAL CHECK Five point calibration with standard and custom buffers ISE Direct calibration and measurement in multiple units Incremental methods: ~ Known addition ~ Known subtraction ~ Analyte addition ~ Analyte subtraction EC Extended range from S/cm to 1 S/cm 3 salinity scales: ~ Practical Salinity ~ Natural Sea Water ~ Percent 240 x 320 dot-matrix color screen Real-time graphic displays HI 2550 Multiparameter ph/orp/ C EC/TDS/ NaCl Bench Meter ideal for laboratories 6 in 1 Bench Meter! Extra wide LCD Extended Temperature Range Up to 5 point ph calibration Log-on Stability Feature USB Port Auto ranging Good Laboratory Practice 14

16 Multiparameter HI Water/Wastewater Multiparameter Photometer Save space in your laboratory 47methods For bench top and eld use Log and recall data at a push of a button Light blocking cuvette holder Backlit LCD On-screen tutorial and context sensitive help screens Parameters include COD, Ammonia, Nitrate, Nitrites, Chlorine, Phosphorus and much more. HI Multiparameter Bench Photometer built for labs, exible for eld use 45methods For bench top and eld use Log and recall data at a push of a button Light blocking cuvette holder Backlit, Graphic LCD On-screen tutorial & context sensitive help screens Conversions are available at the touch of a button Parameters include Ammonia, Chlorine, Fluoride, Manganese, Nitrites, Nitrate, ph and much more. Both the HI & HI are PC compatible via USB 15

17 Multiparameter HI 9829 GPS Multiparameter Portable Meter with Autonomously Logging Probes Display up to 12 parameters Track measurement locations with GPS Field replaceable sensors Now available with eld replaceable ISO 7027 compliant turbidity sensor Auto-recognition of all sensors Four electrode EC sensor Autorange of EC and TDS readings Galvanic oxygen sensor Ammonium, chloride and nitrate ISE s Logging from probe or meter Graphic LCD with backlight Waterproof protection for meter (IP67) and probes (IP 68) Fast Tracker Tag I.D. System simpli es test logging Supports turbidity, ISE s, logging and GPS along with the standard water quality parameters of ph, ORP, DO and EC. HI ph/orp/ise Portable Meter Waterproof Relative mv measurements Up to 7 automatically recognized ph buffers Up to 5 point ph calibration and up to 5 custom buffers Backlit, multi-level LCD display Log on demand (500 samples) Opto-isolated USB 16

18 Dissolved Oxygen HI 4421 Dissolved Oxygen and BOD Meter with graphic, color LCD display Extended range up to 90 ppm and 600% saturation True barometric atmospheric pressure compensation Automatic or user calibration Auto-hold to freeze LCD readings Auto End mode for DO Flexible logging with 3 modes BOD (biochemical oxygen demand), OUR (oxygen uptake rate) and SOUR (speci c oxygen uptake rate) Up to 100 logging lots, 200 OUR and SOUR reports and up to 200 BOD method entries HI 2400 D.O. Bench Meter for Laboratory D.O. readings in mg/l O2 or % of saturation. Automatic calibration procedure, at 1 or 2 points (at 0 and 100% of O2 saturation) Automatic logging interval All logged data can be downloaded to your PC through an RS232 serial port Memory can store up to 8000 samples 17

19 Dissolved Oxygen HI 9142 Dissolved Oxygen Portable Meter perfect for eld work Rugged Field work can subject instrumentation to the inclemency of weather like cold, rain, snow, dust and humidity Very simple to use Polarographic probe Automatic Temperature Compensation Affordable and ef cient Range 0.0 to 19.9 mg/l (ppm) HI 9146 Dissolved Oxygen Portable Meter with graphic, color LCD display On-screen tutorial messages 2 point calibration Auto endpoint Extended range up to 300% Extended altitude compensation to 4000 m Extended salinity compensation to 80 g/l Automatic calibration in air Low battery indicator HOLD function Range O to mg/l (ppm) % Saturation O to 300.0% Temperature to 50.0 C 18

20 Refractometers HI Sodium Chloride Refractometer Easy Measurement and ATC Quick, Precise Results approx 1.5 seconds IP 65 Waterproof Protection Stainless Steel Sample Well easy to clean & resists corrosion Single Point Calibration with distilled or deionized water Small Sample Size as small as 2 metric drops The HI employs the measurement of the refractive index to determine sodium chloride concentration in aqueous solutions used in food preparation. Not intended for seawater salinity measurements. Range 0 to 28 g/100 g; 0 to 34 g/100 ml; to Speci c Gravity; 0 to 26 Baumé Priced around $ 200 for all size labs. HI Ethylene Glycol Refractometer Easy Measurement and ATC Quick, Precise Results approx 1.5 seconds IP 65 Waterproof Protection Stainless Steel Sample Well easy to clean & resists corrosion Single Point Calibration with distilled or deionized water Small Sample Size as small as 2 metric drops The HI digital refractometer measures ethylene glycol as well as it s freezing point in aqueous based solutions such as battery coolants and antifreeze. Range 0 to 100 % volume; 0 to -51 C (32 to F) Freezing Point 19

21 Refractometers Priced around $ 200 for all HI Brix Refractometer Easy Measurement and ATC Quick, Precise Results approx 1.5 seconds IP 65 Waterproof Protection Stainless Steel Sample Well easy to clean & resists corrosion Single Point Calibration with distilled or deionized water Small Sample Size as small as 2 metric drops The HI is an optical instrument that employs the measurement of refractive index to display the sugar content in samples. The measurement of refractive index is simple and quick. Range 0 to 85% Brix size labs. HI Seawater Refractometer for natural or arti cial seawater analysis The HI is a digital refractometer that utilizes the measurement of the refractive index to determine the salinity of natural and arti cial seawater, ocean water or brackish intermediates. Range 0 to 50 PSU; 0 to 150 ppt; to Speci c Gravity (20/20) Easy Measurement and ATC Quick, Precise Results approx 1.5 seconds IP 65 Waterproof Protection Stainless Steel Sample Well easy to clean & resists corrosion Single Point Calibration with distilled or deionized water Small Sample Size as small as 2 metric drops 20

22 Conductivity HI 4321 Conductivity/TDS Meter research grade meter with color display and USP 3 Salinity Scales: Practical Salinity Natural Sea Water Percent 240 x 320 dot matrix color display Logging and graphing capabilities Auto probe recognition (2 or 4 ring & nominal cell constant) Extended range from S/cm to 1 S/cm Stages 1, 2 and 3 USP mode Linear and natural water temperature compensation EC USP Mode HANNA s HI 4521 and HI 4321 can be used to perform all 3 stages of United States Pharmacopeia testing requirements for water quality (USP <645>). The instruments give clear instructions on how to perform each stage and automatically check that the temperature, conductivity and stability are within USP limits. Comprehensive results are shown for all stages on a single screen at the end of the test. Up to 200 reports can be saved for future recall. HI 2300 EC/TDS/NaCl/Temperature Bench Meter with 4-ring platinum probe 4-ring EC probe with internal temperature sensor Automatic (ATC), Manual (MTC) or No Temp Compensation (NoTC) Auto-ranging Good Laboratory Practice PC compatible 21

23 Temperature HI Printing and Logging Thermistor Thermometer Print an indisputable record of your measurements Selectable printing & logging intervals Optional computer compatibility with HANNA s HI compatible Windows software Backlit LCD HI Checktemp 4C HI Checktemp 4F Pocket Thermometer High accuracy Enables measurement at different angles Stainless steel folding probe with penetration tip Ergonomic Incorporated calibration test Auto shut-off HI 93501N Thermistor Thermometers: Accurate, Fast, Reliable Waterproof Thermometer Waterproof Rugged penetration probe Larger LCD Calibration check at startup Missing or damaged probe indicator To view our full line of thermometers visit us at 22

24 Electrodes Combination ph and ORP Electrodes HI 11X1Y Connector HI 1131B BNC HI 1131D DIN HI 1111S Screw Cap HI 1131P BNC+PIN * * For ph meters with CAL CHECK TM system HI 105XY Connector HI 1053B BNC HI 1053D DIN HI 105OS Screw Cap HI 1053P BNC+PIN * * For ph meters with CAL CHECK TM system HI 1083X Connector HI 1083B BNC HI 1083D DIN HI 1083P BNC+PIN * * For ph meters with CAL CHECK TM system HI 1083X Connector HI 1093B BNC 130 mm 120 mm 120 mm 120 mm 12 mm 12 mm 12 mm 3 mm HI 104XY Connector HI 1043B BNC HI 1043D DIN HI 104OS Screw Cap HI 1043P BNC+PIN * * For ph meters with CAL CHECK TM system HI 1135X HI 1135B Connector BNC HI 1143X HI 1143B HI 1143D Connector BNC DIN HI 1144X Connector HI 1144B BNC HI 1144D DIN 120 mm 150 mm 120 mm 120 mm 12 mm 12 mm 12 mm 12 mm 23

25 Electrodes Combination ph and ORP Electrodes HI 12X0Y Connector HI 1230B BNC HI 1230D DIN HI 1210S Screw Cap HI 13X1Y HI 1331B HI 1331D HI 1311S Connector BNC DIN Screw Cap HI 13X0Y Connector HI 1330B BNC HI 1330D DIN HI 1310S Screw Cap HI 1330P BNC+PIN * * For ph meters with CAL CHECK TM system HI 1343X HI 1343B HI 1343D Connector BNC DIN 210 mm 120 mm 120 mm 120 mm 12 mm 5 mm 12 mm 8 mm HI 20XYZ Connector HI 2031B BNC HI 2031D DIN HI 2020S Screw Cap HI 3118X HI 3118B Connector BNC HI 104XY Connector HI 1043B BNC HI 1043D DIN HI 104OS Screw Cap HI 1043P BNC+PIN * 75 mm 150 mm 6 mm 150 mm 12 mm 12 mm 24

26 ISE s Ion Selective Electrodes HI 4002 Half-cell Bromide HI 4102 Combo HI 4003 Half-cell Cadmium HI 4103 Combo HI 4004 Half-cell Calcium HI 4104 Combo HI 4007 Half-cell Chloride HI 4107 Combo HI 4101 Combo Ammonia HI 4105 Combo Carbon Dioxide HI 5315 Reference 25

27 ISE s Ion Selective Electrodes HI 4008 Half-cell Cupric HI 4108 Combo HI 4009 Half-cell Cyanide HI 4109 Combo HI 4010 Half-cell Fluoride HI 4110 Combo HI 4011 Half-cell Iodide HI 4111 Combo HI 4012 Half-cell HI 4112 Combo Lead/Sulfate HI 4013 Half-cell Nitrate HI 4113 Combo 26

28 Solutions ph Standard Calibration Solutions quality solutions for laboratory applications 1.68Buffer Solutions 7.01Buffer Solutions The ph 6.86 buffer solution is standardized with a ph electrode and meter calibrated with NIST buffer solutions. The buffer is certified with NIST standards. 4.01Buffer Solutions For maximum reliability choose from our solutions that meet FDA standards that protect them from extended exposure to light. 9.18Buffer Solutions HANNA s ph 4.01 buffer is standardized with NIST references. HANNA s buffer solutions are prepared using very pure chemicals, in closely controlled laboratories, with ph meters calibrated with NIST references. 6.86Buffer Solutions 10.01Buffer Solutions The ph 6.86 buffer solution is standardized with a ph electrode and meter calibrated with NIST buffer solutions. HANNA s ph buffers are carefully prepared using the highest quality ingredients available and are standardized with NIST references. 27

29 Solutions Electrode Storage Solutions To minimize junction clogging and ensure fast response time, always keep the glass bulb and the junction of your ph electrode moist. Store the electrode with a few drops of HI storage or ph 7.01 buffer solution in the protective cap. General Cleaning Solutions Clean the liquid junction of your electrodes once a day or at least once a week to prevent junction clogging and to maintain accuracy. Immerse the electrode in the proper cleaning solution for at least minutes. HANNA offers a wide range of cleaning solutions, for general purpose and speci c applications to dissolve many deposits from the electrode, and thus ensure correct measurements. 28

30 Accessories Magnetic Mini-Stirrers ABS Plastic HI 190M AISI 316 Stainless Steel HI 200M ABS Plastic HI 180G Electrode Holder HI 76404N HI HI

31 Technical Support Visit us TODAY! Live chat support Instructional product videos Sign-up for promotions Recent product news Upcoming tradeshows Locate distributor HANNA s literature and product manuals Dedicated Technical Support Administration Support Application Support Field Support Training ext. 34 Dedicated Customer Support Service Visits Training Live Chat Support or

32 Laboratory Products Guide Value HANNA is the largest family-owned manufacturer of electroanalytical instrumentation in the world. From instrumentation to electrodes and reagents, all of our products are designed and manufactured in one of our state-of-the-art production facilities. When you buy a HANNA product, you re not only buying the best value for your money, but you re also adding the bene t of HANNA s unsurpassed customer service and post-sale technical support. Rhode Island Of ce 270 George Washington Hwy., Smith eld, RI fax: sales@hannainst.com Michigan Of ce 3820 Packard Road, Suite 120, Ann Harbor, MI fax: laboratory@hannainst.com Lab Guide 3.0 _ 9/2012_Printed in the USA