1 HYUNDAI MIRO-3A Address: , Gongreung-Dong, Nowon-Ku, Seoul, Korea Tel) Fax) Homepage:

2 INDEX Introduction Specifications Installation Instructions Maintenance

3 Introduction 1. Summary of the product 1) Introduction MIRO-3A, a drinking water system using Reverse Osmosis technology, is designed to supply clean and safe water to the shop, market and etc with elegant design and ease of installment. 2) Features of MIRO-3A A flexible product which has various bottle selection function and enables simultaneous use of paper bill or coins. A function of cleaning and sterilization with ozone and automatic pouring. Supply of fresh water with fast water purification capability. Noise and vibration problems are solved by installing in-line pump. A system convenient for opening and closing by using auto door. Supply of clean water with periodic flushing function of membrane. This has no storage container, so as to solve germ and water quality problem even during long time stop. 3) Characteristics (1) Low pressure, high flow R/O membrane Reduced the pressure and noise from pump and remained the high salt rejection rate by using the recently developed R/O membrane for potable water. (2) easy of operation One step operating & controlling system using simple & accurate One-chip Micom(Micro Process Computer)

4 (3) Compact design(easy of installment & relocation) Well planned design by putting in the case & simple steps of installation as connecting to Inlet, Outlet, and Drain line on the backside of the system. (4) Economical efficiency The cost is occurred just by minor power usage, water usage & replacement of filters like membrane, micro filter & activated carbon filter. (5) Inflow control & produced bottle countering function By using auto flow meter, always filling exact amount of product water into the bottle and you could check on the display board how many bottles it product in certain period. (6) Sterilizer U.V sterilizer prevents pollution of produced water through R/O system. Cleaning inside of the bottle with O-ZONE (7) Bottle rotating device Developed the bottle rotating device to make all procedures in one step. 4) Process Flow (System Flow Chat) Raw water Micro Filter A/C Carbon Filter Raw water feed pump Bottle clean R/O Membrane Ozone Generator Post carbon Filter U/V Sterilizer Bottle filling

5 1. General specifications 1) Specifications of the product Capacity Membrane SIZE Electric Salt rejection Model (ton/day) (4040) (L W H) ( kw h) (%) 7 m3 /day , MIN/95% - Coin control : All of countries coins are possible - Application Bottle Size : 2L ~ 1G (International Standard) Basis : Temp 25 degrees C, ph of 7, SDI of 5 or less, NTU under 1, and TDS under 200ppm Performance could be varied with condition of supply water. Please inform HYUNDAI Wacor Tec, the supply water condition Power Requirement : 220V, 1 phase ( option)

6 1. General specifications 2) Standard condition of feed water Pressure Inlet Pressure 0.0 ~ 3.0 kg / cm2 Temperature 5 ~ 30 P.H 5.8 ~ 8.5 Conductivity < 300 μs / cm at 25 Quality of Feed Water T.D.S < 150 mg /l Solid < 1.0 Turbidity < 1.0 Total Hardness < 80 mg /l as CaCO³ Total Fe < 0.1 mg /l Total Mn < 0.05 mg /l Remained Chlorine < 1.0 mg /l

7 1. General specifications 3) Water quality of product water Section Provision Range Conductivity < 25 μs / cm at 25 T.D.S < 10 mg /l Terms Total Hardness < 1.0 mg /l as CaCO³ Total Fe < 0.01 mg /l Remained Chlorine < 0.1 mg /l Living Bacteria < 100 CFU/ mg

8 2. External drawing & arrangement plan 1) External drawing

9 2. External drawing & arrangement plan 2) Arrangement Plan

10 3. Constituent elements of the product

11 3. Constituent elements of the product 2) Diagram Raw Water Raw Water Feed Pump Micro Filter A/Carbon Filter Post Filter Permeate Water Supply Pump Permeate Water Storage Tank(vender scope) R.O Module U.V Sterilizer Bottle Filling Bottle Cleaning Ozone Generator

12 3. Constituent elements of the product 3) Descriptions of components (1) Feed Pump(P-001) Supplying raw water to R/O system & operating automatically upon level switch in storage tank. (2) Supply Pump (P-002) Supplying product water for bottle cleaning & filling. (3) Micro Filter (F-001 ) Removing turbidity, suspended particle & etc. (4) A/Carbon Filter (F-002) Removing organic substance, smell, taste, remained chlorine & etc. (5) R/O Module (F-003) Removing ionic particle, turbidity, bacteria & etc. (6) Post(A/Carbon) Filter (F-004) Removing organic particle, smell, taste still left in product water through R/O module (7) R/O Water Tank(TK-001): Storing product water in storage tank. (8) U.V (F-004) Sterilizing microbe, bacteria & etc. (9) Ozone (OZ-001) : Producing Ozone for cleaning inside of bottle (10) Injector (IJ-1) : Device for mixing Ozone (11) Control Panel : Automatic operation & controlling device

13 3. Constituent elements of the product 4) Descriptions of components Auto valves (1) Solenoid Valve (Sol-1): Supplying raw water (2) Solenoid Valve (Sol-2): Flushing R/O Module (3) Solenoid Valve (Sol-3): Controlling supply of product water into the bottle (4) Solenoid Valve (Sol-4): Controlling supply of interior cleaning water Manually operating valves (1) Glove Valve: Controlling pressure of R/O Module (2) Ball Valve: Controlling inflow & pressure of raw water Gauge (1) Pressure Gauge (PG-1) : Checking pressure of feed pump (2) Pressure Gauge (PG-2) : Checking pressure of concentrated water (3) Pressure Switch (LPS-1): Controlling supply of raw water

14 4. Automatic Control Device 1) Item & description MODE POWER ALARM SET 1 Power / Alarm indicator 2 Operating mode indicator 3 Control Mode Switch ON EMERGENCY STOP OFF 4 EMERGENCY SWTICH 5 KEY BOX (1) Power/Alarm indicator Power of system control Panel/System Malfunctioning indicator (2) Operating mode indicator Displaying system operating Mode, Total operating time, Bottle producing flow, Setting flow rate, alarm message. (3) Control Mode Switch Changing operating mode, flow rate (4) Emergency switch : To stop the system in emergency instantly (5) Prevent of Key Pad's free carve

15 Installation Instructions 1. Required Condition & Precaution 1) Proper place of installation The place of temperature between 1 to 60 The clean inside place The place able to connect raw water pipe and drain water pipe The non-freezing place The non-solar ray place The easy place to vent ventilate the air 2) Power Supply AC 220V, Single phase 50Hz Max 1.4kw 3) Dimension of installation Size (L W H) : ,800 mm

16 Installation Instructions 2. Precaution for operating the system 1) The use of feed water This system is designed basically for the use of city water. This system necessarily need pre-treatment if not to use city water as feed water. 2) Feed water & a power supply This system is always provided with water and power supply because of operating in automatic. 3) Operating condition control This system is operated in the result of feed water condition that is changed by feed water quality, pressure, temperature. This system is operated in best condition by operating setting in automatic before hand-operated. 4) Exchange and maintenance of supplies Check the system periodically and exchange supplies. Check the operating condition periodically and then handle it.

17 Maintenance 1. Replacement time of spare - part Item Standard Replacement time Micro Filter A/Carbon Filter Size: ø L Pore Size : 5 μm Mat'1 : P.P Q'ty: 1 EA/set Size: ø L Mat'1 : A/Carbon Q'ty: 2 EA/set eye checking(strange material) being unused during long time differential pressure over 1.4bar (micro filter) periodically replacement M/F : 1 month, A/C: 3 month Membrane Size : ø100 1,000 L Model : BW 4040-LE Type : PA Q'ty: 1 EA/set not using during long term decreasing product water being pressure difference over 15% than initial operation replacement : 1 ~ 1.5 year U.V Sterilizer Size: ø L Voltage : 220V 60 Hz 16 Q'ty: 1 EA/set being U.V Lamp OFF replacement : 5,000 hours OZ Generator Size: 300L 230W 90H Dosage: 0.02ppm/hr Q'ty: 1 EA/set not detecting smell of Ozone replacement : 12,000 hours

18 Maintenance 2. Routine maintenance requirements Checking point Every day Every week Every month Every 6 month Every year Leakage of pipe/hose Manual V/V open/close Operation pressure and Flow rate Filter condition Membrane Pressure switch & Pressure gauge Pump Bottle Turning Part Gripper standard position (Sensor detecting) U.V Sterilizer Ozone Leakage of electricity