1 SEAC, Gujarat: Page 1 of 11 Synthetic Organic Chemicals 5(f) For appraisal Environmental Clearance [EC] New Project 1. Basic Information of the Project: i Name & Address of the Project site (Complete details with plot /Survey, Landmark etc. ) M/s. Gurawe Colours Plot No. 2900/149, GIDC Estate, Ankleshwar, Dist. Bharuch , Gujarat. ii Name of the Applicant Jaisukh N. Nakrani iii Address for correspondence 303, Garden Tulsi, Plot No. 801/4, Nr. Sardar Park Chowkdi, GIDC, Ankleshwar iv Contact and ID of the Applicant Mo. : Jai.Nakrani79@Gmail.Com v Aerial distance of nearest Habitat (KM) Ankleshwar 2.5 km vi Longitude & Latitude of the Project Site: (4 corners of the site) vii Category as per the Schedule to the EIA Notification 2006 i.e. 1(d), 2(b), 5(f) etc. Sub Category: i.e. Dyes, Dyes Intermediates, Specialty chemicals, Bulk Drugs etc. viii Applicability of General Conditions of EIA Notification 2006: i.e. Ensure that I. Protected areas notified under the Wildlife (Protection) Act, 1972; II. CEPI areas III. Ecosensitive areas and IV. Interstate boundaries and international boundaries; are not located within 5 km or 10 km (as the case may be) area from the boundary of the proposed site '55.49"N 73 1'18.08"E 21 37'55.16"N 73 1'17.69"E 21 37'55.15"N 73 1'18.34"E 21 37'55.84"N 73 1'17.76"E 5 (f) Synthetic Organic Chemicals SubCategory: Dyes (1) Not Applicable as unit is located in Notified Industrial Area (2) Not Applicable as unit is located in Notified Industrial Area (Ankleshwar/Gujarat) (3) Not Applicable as unit is located in Notified Industrial Area (Ankleshwar/Gujarat) (4) Not Applicable as unit is located in Notified Industrial Area (Ankleshwar/Gujarat 2. Online application & PH reg.: a) Date of SEAC meeting for Tor Granted by MOeF, Delhi Page 1 of 11

2 SEAC, Gujarat: Page 2 of 11 recommendation to grant TOR: b) Online application proposal : SIA/GJ/IND2/28108/2017 c) Date online acceptance of EC application by SEAC: d) TOR issued by SEIAA: Letter no & date. J11011/68/2017IA(I) vide dated e) Date of Public Hearing Proposed Project is located in (If applicable): Notified Industrial Area of GIDC, Ankleshwar. Hence Public Hearing is exempted. f) Date of presentation for Appraisal: 3. Product profile: Sr. Name of the Products CAS /CI Quantity No. 1 Acid Orange Acid Red Acid Red Acid Yellow Acid Blue Acid Black Direct Orange Direct Red Direct Yellow Direct Violet Direct Green MT/MONTH 12 Direct Black Reactive Yellow (Yellow MGR) 14 Reactive Blue (Brilliant Blue MR) 15 Standardization of Dyes & Pigments (Drying & Packing) 20 MT/MONTH TOTAL 35 MT/MONTH Enduse of products Dyes & Dyes Intermediates The project falls under the Category B of project activity 5(f) asper the schedule of EIA Notification Product wise Raw material consumption: Sr. Name of the Products Name of the Raw Materials CAS / CI of raw materials. Quantity Page 2 of 11

3 SEAC, Gujarat: Page 3 of 11 1 ACID ORANGE7 Sulfanilic acid Caustic Flakes HCl NaNO Beta Napthol Soda Ash ACID RED88 Sodium Napthonate Soda Ash HCl NaNO Beta Napthol Soda Ash ACID RED18 Sodium Napthonate HCl NaNO Soda Ash G. Salt ACID YELLOW36 Metanilic Acid Soda Ash Caustic NaNO Diphenyl Amine Emulsifier ACID BLUE113 Metanilic Acid HCl NaNO Napthyl Amine Soda Ash Acetic Acid Phenyl Peri Acid ACID BLACK1 Para Nitro Aniline HCl NaNO Aniline H. Acid Soda Ash DIRECT ORANGE26 Aniline Oil HCl NaNO JAcid Urea Soda Ash DIRECT RED31 Aniline HCl NaNO Rohduline Acid Soda Ash Page 3 of 11

4 SEAC, Gujarat: Page 4 of 11 Caustic Flakes Sodium Acetate DIRECT YELLOW4 DASDA HCl NaNO Phenol Caustic Soda Ash DIRECT VIOLET9 Sulfanilic Acid HCl NaNO PCresidine Sodium Acetate Phenyl JAcid Soda Ash DIRECT GREEN8 Vinyl Sulphone HCl NaNO H. Acid Caustic Phenol Sodium bicarbonate Soda Ash DIRECT BLACK29 F.C. Acid HCl NaNO H. Acid Soda Ash M.P.D REACTIVE YELLOW7 NASDA 6.3 HCl NaNO NMethyl JAcid Sodium Acetate Soda Ash Cynuric Chloride REACTIVE BLUE4 MPDSA HCl Bromamine Acid Nitrogen Calsonil Oil 0.3 Octanol Oil Sodium Bicarbonate NaCl Cynuric Chloride Soda Ash Page 4 of 11

5 SEAC, Gujarat: Page 5 of Salient features of the project including Water, Air and Hazardous waste management: Sr. Particulars Details A Total cost of Proposed Project 0.8 Crores (Rs. in Crores): B Total Plot area ( sq. meter) Sq. m. Green belt area,/tree Plantation area ( sq. meter) C Employment generation D Water i Source of Water Supply 60.0 Sq. m. Direct15 Indirect15 GIDC water supply (GIDC Bore well, Surface water, Tanker supply etc...) Status of permission from the concern authority. No./GIDC/DEE(W/S)/ KL ii Water consumption (KLD) Category KLD Remarks (A) Domestic 0.8 GIDC water (B) Gardening 0.6 supply (C) Industrial Process 1.15 Washing 0.5 Boiler 1.1 Cooling 1.25 Others 0.0 Industrial Total Total (A + B + C) 1) Total water requirement for the project: 5.4 KLD 2) Quantity to be recycle: 0.0 KLD 3) Total fresh water requirement: 5.4 KLD iii Waste water generation (KLD) Category Waste water KLD Remarks Page 5 of 11

6 SEAC, Gujarat: Page 6 of 11 (A) Domestic 0.60 (B) Industrial Process 1.95 Washing 0.5 Boiler 0.1 Cooling 0.1 Others 0.0 Total Industrial 2.65 waste water Total [A + B] 3.25 iv Treatment facility within premises with capacity [Inhouse ETP (Primary, Secondary, Tertiary), MEE, Stripper, Spray Dryer, STP etc.. ETP=3.0 KL/DAY v Mode of Disposal & Final meeting point Domestic: septic tank & soak pit Industrial: The industrial effluent (2.65 KL/Day) will be treated in ETP consists of primary treatment then it will be sent to Common MEE for further treatment & disposal. vi In case of Common facility (CF) like CETP, Common Spray dryer, Common MEE etc., Name of CF Common MEE of M/s. ACPTCL, Ankleshwar Membership of Common facility (CF) vii Reuse/Recycle details (KLD) 0.0 KLD E Air i Flue gas emission details No. of Boilers/TFH/Furnaces/DG sets etc. with capacities viz. TPH, Kcal/hr, MT/hr, KVA etc. Sr. Source of emission With Capacity 1 Steam Boiler (800 Kg/Hr) Stack Height (meter) Type of Fuel 30.0 Agro waste or Briquettes Quantity of Fuel MT/Day 25 Type of emissions i.e. Air Pollutants PM=150 mg/nm3 SO2=100 ppm NOx=50 ppm Air Pollution Control Measures (APCM) Multi cyclone Separator with bag filter Page 6 of 11

7 SEAC, Gujarat: Page 7 of 11 ii Process gas i.e. Type of pollutant gases (SO 2, HCl, NH 3, Cl 2, NO x etc.) Sr. Source of emission Type of emission Stack/Vent Height (meter) Air Pollution Control Measures (APCM) There shall be no process emission from the manufacturing process as well as Ancillary process. iii Fugitive emission details with its mitigation measures. As below: Minimum number of flanges, joints and valves in pipelines Selection / use of stateofthe art leak proof valves Provision of mechanical seals in pumps Proper preventive maintenance of roofs and seals for tanks Monitoring and preventive maintenance of valves, flanges, joints, etc. Fugitive emission over reactors, formulation areas, centrifuges, chemical loading, transfer area, shall be collected through hoods and ducts by induced draft and controlled by dust collector. For particulate / dust emissions from the coal handling system: Water will be sprinkled to control particulate / dust emission from coal storage area. F Hazardous waste (as per the Hazardous and Other Wastes (Management and Transboundary Movement) Rules i Sr. Type/Name of Hazardous waste 1 Discarded Container/ Barrel/ Liners Source of generation From Raw Material Category and Schedule as per HW Rules. SCHI 33.1 Quantity (MT/Annum) 0.5 Disposal Method Collection, Storage, Decontamination, Transportation and Reuse or sell to registered recyclers Page 7 of 11

8 SEAC, Gujarat: Page 8 of 11 2 Used / Spent Oil From Machinery SCHI ETP Sludge From ETP SCHI 35.3 ii Membership details of TSDF, CHWIF etc. iii Details of NonHazardous waste & its disposal (MSW and others) BEIL/ANK/ JAN,2017 Collection, Storage, Transportation and Disposal by Sell to registered reprocessor Collection, Storage, Transportation & Disposal at TSDF site (M/s. BEIL, Ankleshwar) G Solvent management, VOC emissions etc. i Types of solvents, Details of Solvent recovery, % recovery. reuse of recovered Solvents No solvent use ii VOC emission sources and its mitigation measures Enclosed process, Pumps will be having double mechanical seals Proper ventilation with hood Regular maintenance & monitoring Adequate PPE s 6. Details regarding EIA report: Sr. Particulars Details Page, Section & chapter of EIA report a Ensure that there is no change in EIA report w. r. t. ToR i.e. Form1 & PFR Chapter2, change mode of disposal In Common MEE. Section 2.5.3, March, 2017 to May, 2017 page 7884 b Baseline environmental monitoring Chepter3 period c Baseline study area (Km) 10 Km Chep3 page 99 d No. of AAQM stations including project 9 AAQM Stations Chep3 page site 99,100 Page 8 of 11

9 SEAC, Gujarat: Page 9 of 11 Conclusion of the Monitoring (Baseline study) Air, Water & Land All parameter of air, water and land are found within standards e Parameters considered for AAQM including project specific parameters. Sr. Parameters Range of Concentrations (µg/m 3 ) Remarks 1 PM All parameter of air, 2 PM water and land are 3 SO found within 4 NOx standards. 5 NH O Pb BDL 8 As BDL 9 Ni C6H6 BDL 11 HC BDL 12 CO VOC f Whether the results of AAQM is within the Yes. norms prescribed in NAAQS? If no, give reasons as per EIA report g Comments for AAQM results w. r. t. NAAQS h Software used for the mathematical Modelling for anticipated incremental GLCs (Ground Level Concentrations) i The resultant concentrations w. r. t. NAAQS and its conclusion. All air parameters are found within the norms. Industrial Source Complex Short Term (ISCST3) dispersion model is a steadystate Gaussian plume model Within Limit Chapter3 Section3.4.1 page Chepter4 Chepter3 j Suggested mitigation measures w. r. t. Air Proper Action Plan to curb air pollution Chepter3 Page 9 of 11

10 SEAC, Gujarat: Page 10 of 11 k Conclusion of the Monitoring during baseline study of water l Suggested mitigation measures w. r. t. Water m Conclusion of the Monitoring during baseline study of Land n Suggested mitigation measures w.r. t. Land o Conclusion of the Monitoring during baseline study of Noise p Suggested mitigation measures w. r. t. Noise All parameters are found within the norms. Effective EMP Monitoring plan All parameters are found within the norms. Effective EMP Monitoring plan All parameters are found within the norms. Effective EMP Monitoring plan chapter3 section page Chepter7 Chepter3 Page No Chepter7 All parameters are found within the norms. Chepter7 q Main issues in Public hearing (If applicable) r Brief description of Public hearing (If applicable) Not Applicable unit is located in Ankleshwar GIDC Not Applicable Main Issues raised by stake Commitments by Project proponent and holders action plan. Not Applicable as unit is located in Notified Industrial Area (Ankleshwar/ Gujarat) s Major hazardous chemicals and worst case scenario considered in Risk Analysis report. Section Chapter6 Page No Comments/Suggestions/mitigation measures in brief Section Chapter6 Page No t An undertaking by the Project Proponent (PP) on the ownership of the EIA report as per the OM of MoEF&CC dated 05/10/2011 and an undertaking by the Please refer Declaration by Experts Contributing to the EIA Report Page 10 of 11

11 SEAC, Gujarat: Page 11 of 11 Consultant regarding the prescribed TORs have been complied with and the data submitted is factually correct as per the OM of MoEF&CC dated 04/08/2009. u Any other details: No. 7. Details of Environmental Consultant: Sr. Particulars i Name of the Consultant ii Contact and ID of the Consultant iii Accreditation for the categories and Validity Details AquaAir Environmental Engineers Pvt. Ltd. Mo. : aqua_eia@yahoo.com Stay order against NABET/QCI iv Any other details Name & designation of the Applicant: General Instructions Format shall be in WORD Format (Font type Arial, Font size 11) Do not change Format. Fill up your details / information in prescribed tables. Provide authenticated (with stamp & Signature) hard copy during presentation. Kindly send to : seacgujarat@gmail.com Above data shall be as per application Form1 & PFR. Incorporate relevant details in respective column in the Format. Do not attach Annexure except copy of Certificates etc. Page 11 of 11