Online data sheet MAC800 CUSTOMIZED ANALYZER SYSTEMS

Size: px
Start display at page:

Download "Online data sheet MAC800 CUSTOMIZED ANALYZER SYSTEMS"

Transcription

1 Online data sheet MAC800

2 A B C D E F H I J K L M N O P Q R S T certified certified Ordering information Type MAC800 Part no. On request The exact device specifications and performance data of the product may deviate from the information provided here, and depend on the application in which the product is being used and the relevant customer specifications. Our regional sales organization will help you to select the optimum device configuration. Other models and accessories Product description The MAC800 complete system is an economic and technically perfect solution for extractive measuring tasks. Its fully configurable design with high-quality standard subassemblies and components allows a configuration optimally tailored to the individual requirements. Retrofitting with analyzer modules or gas conditioner components is easy and inexpensive. The innovative MAC800 system is certified according to European standard EN and provides solutions fit for the future for emission measurement and process applications. At a glance Cold-extractive analyzer system certified according to EN Plug-and-play analyzer modules with 24 V power supply Operating unit for displaying all measured values and status information on a touch screen External sensors via interfaces connectable Display and control of external sensors is possible Remote control of the complete system via Ethernet, Modbus or additional GPRS modem Your benefits Forward-thinking investment, as the system can be adapted easily to meet future needs Easy commissioning and trouble-free on-site approval of the automated measuring system (AMS) by the relevant authorities Full overview via touch screen and connected remote sensors (p, T, volume flow, dust) Easy service due to clear separation of the electrical system and the analyzer component Easy and quick module replacement for high availability Ethernet or Modbus network connection 2 SYSTEM SOLUTIONS SICK Online data sheet :41:26 Subject to change without notice

3 Fields of application Emission monitoring for plants with lignite or hard coal firing Emission monitoring for gas-fired power plants, gas turbines, or combined cycle plants Emission monitoring for small and medium boilers Measurement of greenhouse gases Detailed technical data MAC800 system Measured values CH 4, CO, CO 2, H 2, NO, NO 2, N 2 O, O 2, SO 2, other components on request Measuring methode Gas flow rate Extractive measurement 30 l/h l/h With bypass pump: 250 l/h For short response times Process temperature +1,000 C Depending on sampling probe Sample gas temperature +200 C Temperature at cabinet inlet Process gas humidity Non-condensing Ambient temperature +5 C C With cooling device: +5 C C Storage temperature 20 C C Ambient humidity 75 % Relative humidity; non-condensing Conformities Electrical safety Approved for plants requiring approval 2001/80/EC (13. BImSchV) 2000/76/EC (17. BImSchV) EN EN MCERTS GOST Enclosure rating IP 54 With cooling device: IP 34 Analog outputs Analog inputs Digital outputs Digital inputs Interfaces CE 2 outputs: 0/ ma, 500 Ω ; electrically isolated 2 inputs: 0/ ma, 100 Ω ; electrically isolated 2 power relays, changer: 48 V AC/DC, 5 A, 340 W 3 change-over contacts: 48 V AC/DC, 0.5 A, 24 W 4 NO: 48 V AC/DC, 5 A, 340 W 4 inputs: Open contacts, potential-free; max. number of inputs depends on application RS-232 (option) RS-422 (option) RS-485 (option) :41:26 Online data sheet Subject to change without notice SYSTEM SOLUTIONS SICK 3

4 A B C D E F H I J K L M N O P Q R S T Bus protocol Model Weight Mounting Power supply Corrective functions Integrated components Options Modbus TCP OPC Steel sheet cabinet Versions with NO x -converter (option) Versions with cooling or heating device (option) GRP cabinet 250 kg kg Depending on version Under roofing or other protection against exposure to direct heat radiation, high dust loads and corrosive atmospheres Depending on version Manual adjustment with test gases Automatic testing and adjustment with test gases Sample gas pump Sample gas cooler NO x -converter Cooling device Heating Bypass pump 4 SYSTEM SOLUTIONS SICK Online data sheet :41:26 Subject to change without notice

5 Online data sheet SICK at a glance SICK is one of the leading manufacturers of intelligent sensors and sensor solutions for industrial applications. A unique range of products and services creates the perfect basis for controlling processes securely and efficiently, protecting individuals from accidents and preventing damage to the environment. We have extensive experience in a wide range of industries and understand their processes and requirements. With intelligent sensors, we can deliver exactly what our customers need. In application centers in Europe, Asia and North America, system solutions are tested and optimized in accordance with customer specifications. All this makes us a reliable supplier and development partner. Comprehensive services complete our offering: SICK LifeTime Services provide support throughout the machine life cycle and ensure safety and productivity. For us, that is Sensor Intelligence. Worldwide presence: Contacts and other locations SICK AG Waldkirch Germany