NANOCOLOR Compact photometer PF-12 Plus

Size: px
Start display at page:

Download "NANOCOLOR Compact photometer PF-12 Plus"

Transcription

1 MACHEREY-NAGEL NANOCOLOR Compact photometer Water Analysis Increased flexibility n Reliable Easy handling for precise results n Mobile Robust and waterproof n Versatile Nephelometric turbidity measurement and NTU-Check

2 Compact photometer Increased flexibility The compact photometer is tailor-made for the mobile water analysis, to evaluate our proven MACHEREY-NAGEL VISOCOLOR ECO tests and our NANOCOLOR tube tests. The icon-based user guidance and the new task bar turn the into a user friendly, easy and intuitively operated photometer for all scope of applications in water and waste water analysis. The delivery is carried out in a robust case, equipped with helpful accessories, allowing for an analysis directly at the point of interest. For an overview of the VISOCOLOR ECO and NANOCOLOR tube tests, evaluable on the, look at page 6, 7 and 8. Save time make work easier The is already equipped with more than 100 preprogrammed methods and additional functions. Because of the easy handling, measurement results can be produced within seconds. Backlit graphic display with intuitive user guidance nready to use immediately nall tests and menu items can be activated fast and easily nperfect handling without extensive training : COD mg/l 0ã 0001 Dueren ^_ ä EXT 10 Z M Method: - Settings Basic functions Tube tests VISOCOLOR-ECO ^_ Method ^_ M: :30 Preprogrammed tests and basic functions nmore than 100 preprogrammed methods nmanual with test instructions displayed as pictograms Phosphat Test 5-84 Phosphate / Fosfato REF nm 5841 Nitrat0.5.0 mg/l PO 4 P Test Nitrate / Nitrato mg/l PO 4 REF nm 5411 Eisen mg/l 1 NO3 N Iron / Fer / Hierro mg/l NO3 540 nm Test 5-25 REF Chlor (gesamt) mg/l Fe Test 5-15 Chlorine (total) / Chlore (totale) / Cloro (total) REF Küvetten spülen 5 ml Probe 6 PO nm Rinse test tubes Sample Rincer les éprouvettes Echantillon Lavar los tubos Muestra 5152 Ammonium mg/l Cl 15 2 Test 5-10 Amonio REF Küvetten spülen 5 ml Probe 5 NO nm Rinse test tubes Sample Rincer les éprouvettes Echantillon Lavar los tubos Muestra mg/l NH 4-N mg/l NH Küvetten mg/l NH spülen 3 5 ml Probe 5 Fe-1 Rinse test tubes 6 Sample PO 4-2 Säubern min Rincer les éprouvettes Echantillon Clean Lavar los tubos Muestra Nettoyer Limpiar 3 Cl Cl ml Probe 1 NO3-2 1 min Sample Kräftig schütteln Echantillon well Muestra Bien agiter intensamente Säubern Clean Nettoyer Limpiar 5 00 min Küvetten spülen Rinse test tubes Rincer les éprouvettes Lavar los tubos 5 ml Probe Sample Säubern Echantillon Clean Muestra Nettoyer Limpiar 10 NH min Messung Measurement Mesure Messung Measurement Mesure 1 NH Cl 2-3 Säubern 2 00 min Messung Clean Meerwasser Measurement Nettoyer Mesure Limpiar Eau de mer Agua de mar 5 00 min Meerwasser Eau de mer Agua de mar 4 NH 4-3 Messung Measurement Mesure Meerwasser Eau de mer Agua de mar 1 9 Meerwasser Eau de mer Agua de mar Säubern Meerwasser Clean Nettoyer Eau de mer Limpiar Agua de mar 7 00 min Messung Measurement Mesure 2

3 Compact photometer Minimize errors experience precision An 860 nm LED enables the nephelometric turbidity measurement in the range of NTU. This feature allows for the well established NTU-Check of our MACHEREY-NAGEL spectrophotometers now also on the ; a big PLUS in terms of safe measurement results. In addition turbidity in transmitted light, between 4350 FAU, can be determined. Highest accuracy nwarning of potential interferences by fully automatic turbidity control measurement with 90 (NTU-Check) ndisplay of the 2080 % measurement range bar Turbidity An error source: Turbidity within a cuvette is often underestimated because it is not always visible. With the integrated turbidity control (NTU- Check), turbidity within the sample is determined for every measurement and in case of an interference the operator is warned. A B A B Measurement without cuvette slot cover nthe state-of-art optical system is insensitive to external light and allows straightforward measurements without cuvette slot cover 2 cuvettes (A B) with similar COD-concentrations. The turbidity in cuvette B influences the result up to 30 %. Fulfill requirements assure results The GLP-conform data, stored after each measurement, can be transferred conveniently to the PC via the NANOCOLOR data export software and evaluated with the PC-standard-software. Clear memory management nglp-conform storage of results incl. date, time, sample number, sample location and dilution nfast and easy access to stored results and data sets Convenient data export nnanocolor software DVD included in delivery neasy transfer of results to PC ndata export directly to MS EXCEL nrecording of calibration curves to program user-defined methods Internal quality control according to ISO 9001 nfulfill supervisor and authority requirements nfast and easy self-monitoring of photometric accuracy with NANOCONTROL NANOCHECK (REF ) 3

4 Compact photometer Be mobile enjoy versatility Due to its compact size and the robust and waterproof housing, the fits perfectly for measurements directly at the sampling site. Aside the preprogrammed methods the offers the possibility to install up to 50 special methods for customer specific applications. Step by step functions up to fourth-degree and logarithmic functions can be programmed this way. Via the USB-port the device can be updated with new tests and methods in a minimum of time. Works under any condition nvariable power supply for mobile use nwaterproof housing (IP68) nbattery info and status The can be used even under hardest conditions. This was officially confirmed by the military science department of the German armed forces, where the instrument underwent shaking inquiries at different frequencies. Even under such stress the device stayed fully functional. The therefore is the only photometer of its class, which fulfills the strict requirements of the regulation MIL-STD Free programming of user-defined methods nprogrammable for 50 user-defined methods n4th degree polynomial with ln-function Fast photometer update free of charge nat any time, stay up-to-date with our easy online software update nfor current software updates please visit A wide range of applications Adjusted to today s and future customer needs, the is suitable for universal use in all fields of water and waste water analysis. Including municipal and industrial waste water, drinking water, surface water, ground water and boiler feed water. n Public authorities n Metalworking industries and galvanics n Industrial laboratories n Fish farmers n Maintenance companies for mobile water analysis n Schools and universities Drinking water Brewery Metal processing industry Sewage plant Pool & spa care 4

5 Compact photometer Individual mini-labs For the several variants of reagent cases are available, allowing the individual assembly of a mini-lab. VISOCOLOR Reagent case for environmental analysis with nreagent case with and VISOCOLOR ECO test kits for the following parameters n Ammonium n Carbonate hardness n Iron n Nitrate n Nitrite n ph n Phosphate n Total hardness n and accessories nthe allrounder for all applications ncost-efficient refill packs REF VISOCOLOR Reagent case with nreagent case with and room for individual equipping with n QUANTOFIX test strips n ph-fix test strips n ph indicator papers n Qualitative test papers n VISOCOLOR test kits ninfinite options nroom for accessories and integrated cuvette stand REF NANOCOLOR Reagent case with nreagent case with and room for individual equipping with n Heating block NANOCOLOR VARIO C2 or NANOCOLOR VARIO Mini Example: Fully assembled VISOCOLOR Reagent case n Two piston pipettes n Three packages of NANOCOLOR tube tests n Accessories nespecially for the fast and secure maintenance of small sewage treatment plants nhighest transport safety by exceptionally robust cases REF Example: Fully assembled NANOCOLOR Reagent case 5

6 Compact photometer Test Measuring range Wavelength No. of tests Shelf life (years) VISOCOLOR ECO Alkalinity TA 5250 mg/l CaCO / yes Ammonium 3* mg/l NH Ammonium 15* mg/l NH Bromine mg/l Br yes Chloride* 150 mg/l Cl no Chlorine 1, free total mg/l Cl yes Chlorine 2, free total* mg/l Cl no free Chlorine mg/l Cl no Chlorine 6, free total mg/l Cl yes free Chlorine mg/l Cl yes Chlorine dioxide* mg/l ClO no Chromium (VI)* mg/l CrO yes Copper mg/l Cu yes Cyanide* mg/l CN Cyanuric acid* mg/l Cya yes Fluoride mg/l F after destillation Hydrazine* mg/l N 2 H yes Iron 1* mg/l Fe yes Iron mg/l Fe yes Manganese* mg/l Mn yes Nickel* mg/l Ni Nitrate* 460 mg/l NO yes Nitrite mg/l NO yes Oxygen* 18 mg/l O yes ph ph / yes Phosphate* mg/l PO 4 -P mg/l PO yes Potassium* 25 mg/l K Silica mg/l SiO yes Silica HR 200 1) mg/l SiO yes Sulfate* mg/l SO Sulfide* mg/l S yes Zinc mg/l Zn NANOCOLOR tube tests Aluminium mg/l Al yes Ammonium 3* mg/l NH 4 -N mg/l NH Ammonium 10* mg/l NH 4 -N mg/l NH yes Ammonium 50* mg/l NH 4 -N mg/l NH yes Ammonium 100* 480 mg/l NH 4 -N 5100 mg/l NH yes Ammonium 200* mg/l NH 4 -N mg/l NH yes Ammonium 2000* mg/l NH 4 -N mg/l NH yes AOX 3* mg/l AOX mg/l AOX yes BOD 5 * mg/l O yes BOD 5 -TT* mg/l O yes Cadmium mg/l Cd yes Carbonate hardness e mmol/l H 436 / yes Chloride 50* mg/l Cl no Chloride 200* 5200 mg/l Cl g/l Cl Chlorine / Ozon 2* mg/l Cl mg/l O yes Chlorine dioxide mg/l ClO yes Chromate mg/l Cr(VI) mg/l CrO yes total Chromium 2* mg/l Cr no COD 40* 40 mg/l O at 8 ºC no COD 60* 560 mg/l O at 8 ºC no COD 160* mg/l O no COD 160 Hg-free* mg/l O at 8 ºC no COD 300* mg/l O no COD 600* mg/l O at 1525 ºC no COD 1500* mg/l O no COD 1500 Hg-free* mg/l O no COD 4000* mg/l O at 1525 ºC no COD 10000* g/l O no COD 15000* g/l O no COD 60000* g/l O no * This product contains harmful substances which must be specially labeled as hazardous. For detailed information please see SDS. 1) For evaluation with PF-12/ a special filter is necessary REF 6

7 Compact photometer Test Measuring range Wavelength No. of tests Shelf life (years) COD LR 150* 3150 mg/l O no COD HR 1500* mg/l O no org. Complexing agents mg/l I BiC (Screeningtest) Copper mg/l Cu yes Cyanide 08* mg/l CN DEHA 1 (Diethylhydroxylamin) mg/l DEHA yes Ethanol g/l EtOH Vol. % at < 0 C no EtOH Fluoride mg/l F Formaldehyde 8* mg/l HCHO no Formaldehyde mg/l HCHO yes Hardness Ca / Mg ºe; 550 mg/l Mg mmol/l; mg/l Ca 2 Hardness ºe; 550 mg/l Mg mmol/l; mg/l Ca 2 HC 300* (hydrocarbons) mg/l KW mg/kg KW yes Iron 3* mg/l Fe yes Lead 5* mg/l Pb no Manganese 10* mg/l Mn yes Methanol mg/l MeOH at < 0 ºC no Molybdenum 40* mg/l Mo (Vl) mg/l MoO no Nickel 4* mg/l Ni Nitrate 8* mg/l NO 3 -N mg/l NO no Nitrate 50* mg/l NO 3 -N 100 mg/l NO no Nitrate 250* 460 mg/l NO 3 -N mg/l NO no Nitrite 2* mg/l NO 2 -N mg/l NO yes Nitrite mg/l NO 2 -N mg/l NO yes total Kjeldahl nitrogen TKN mg/l TKN no total Nitrogen TNb 22* mg/l N no total Nitrogen TNb 60* 360 mg/l N no total Nitrogen TNb 220* 5220 mg/l N no Organic acids 3000* mg/l CH 3 COOH mmol/l yes CH 3 COOH Oxygen 12* mg/l O yes Peroxide mg/l H 2 O at 8 ºC yes ph 6,58,2 ph / yes Phenolic index 5* mg/l Phenol after extraction ortho and total Phosphate LR 1* mg/l P mg/l PO yes ortho and total Phosphate 1* mg/l P mg/l PO yes ortho and total Phosphate 5* mg/l P mg/l PO yes ortho and total Phosphate 15* mg/l P mg/l PO yes ortho and total Phosphate 45* mg/l P mg/l PO yes ortho and total Phosphate 50* mg/l P mg/l PO yes POC mg/l Potassium 50* 50 mg/l K Residual Hardness ºe mmol/l no Silver mg/l Ag no Starch 100* 5100 mg/l Starch Sulfate 200* mg/l SO no Sulfate 1000* mg/l SO no Sulfate LR 200* mg/l SO no Sulfide 3* mg/l S Sulfite 10* mg/l SO Sulfite 100* 5100 mg/l SO yes Anionic surfactants 4* mg/l MBAS Cationic surfactants 4* mg/l CTAB Nonionic surfactants 15* mg/l Triton X no Thiocyanate 50* mg/l SCN * This product contains harmful substances which must be specially labeled as hazardous. For detailed information please see SDS. 1) For evaluation with PF-12/ a special filter is necessary REF 7

8 Compact photometer Test Measuring range Wavelength No. of tests Shelf life (years) Tin 3* (special filter required) mg/l Sn TOC 30* mg/l C no TOC 300* mg/l C no TTC / Sludge activity150* 5150 µg TPF; E at 8 ºC no Zinc 4* mg/l Zn Zirconium mg/l Zr yes * This product contains harmful substances which must be specially labeled as hazardous. For detailed information please see SDS. 1) For evaluation with PF-12/ a special filter is necessary REF Technical Data Type Filter photometer with microprocessor control, self-test and auto-calibration Wavelength range nm Optics Automatic filter wheel with 7 interference filters Insensitive to external light for fast measurements without cuvette slot cover Wave-lengths 345 / 436 / 470 / 540 / 585 / 620 / 690 nm plus 1 compartment for an additional filter, 860 nm LED for NTU-measurement Wavelength accuracy ± 2 nm, bandwidth at half transmission 1012 nm Light source Xenon high pressure lamp Detector Silicon photodiode Blank value Automatic Measuring modes Over 100 preprogrammed tests (NANOCOLOR tube tests and VISOCOLOR ECO tests) Absorbance, transmission, factor, standard, 50 freely programmable methods Photometric range ± 3 A Photometric accuracy ± 1 % Stability < E/h Cuvette holder Round tubes 16 mm OD Data memory 1000 results, GLP conform Display Backlit graphic display, 64 x 128 pixels All important data at a glance: Result in respective unit, date, time, sample number, dilution, measuring range control bar Auto-Off function Inactive or automatic deactivation after 5 min, 10 min, 15 min, 20 min, 60 min Quality Control With NANOCONTROL NANOCHECK Operation Self-explanatory menu guidance, foil keypad, test selection via parameter lists Interface USB 2.0 Languages DE / EN / FR / ES / IT / NL / HU / PL / PT / CZ / ID / SL / TR / MY Update For free via internet / PC Operating range 10 C40 C, up to 80 % relative humidity (non-condensing) Power supply 4 AA batteries, rechargeable batteries, USB interface; optional internal accu-pack Housing Shock-resistant; waterproof and dustproof, according to IP 68 Dimensions 215 mm x 100 mm x 65 mm Weight 0.7 kg Warranty 2 years CE CE certified Ordering information Description REF Compact photometer Incl. software DVD, manual, 4 batteries, 4 empty test tubes, funnel, beaker, syringe, USB cabel, calibration cuvette and certificate in rugged case Accu pack USB power supply Charger darknightsky, Marijan Kucan, Eisenhans fotolia.com KATEN Broschüre en3 / 1 / 0 / DD Printed in Germany MACHEREY-NAGEL GmbH & Co. KG Neumann-Neander-Str Düren Germany DE / International: CH: FR: US: Tel.: Fax: info@mn-net.com Tel.: Fax: sales-ch@mn-net.com Tel.: Fax: sales-fr@mn-net.com Tel.: Fax: sales-us@mn-net.com