Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Size: px
Start display at page:

Download "Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005"

Transcription

1 Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL according to DIN N ISO/IC 17025:2005 Period of validity: to Holder of certificate: Framatome GmbH Testing Laboratory Therminal Hydraulics and Components Testing at the locations Paul-Gossen-Straße 100, rlangen Seligenstädter Straße 100, arlstein Tests in the fields: thermally, fluidic and process-engineering investigations and diagnostics of components and systems of power or process plants under operational and accident conditions as well as type and repeated in-service tests Abbreviations used: see last page Within the given testing field the testing laboratory is permitted, without being required to inform and obtain prior approval from DAkkS, the free choice of standard or equivalent testing methods and the modification, development and refinement of testing methods. The listed testing methods are exemplary. The testing laboratory maintains a current list of all testing methods within the flexible scope of accreditation. The used test methods are identified with the symbols of the locations stated below: = rlangen = arlstein This document is a translation. The definitive version is the original German annex to the accreditation certificate. 1/5

2 1 Thermo- and fluid mechanics FAW-T FAW-T-3021 Thermal hydraulic investigations for devices, facilities and components of power or process plants Instruction for performing tests of pressure drop and critical heat flux measurements with the ATHY test facility Testing of fluid dynamic devices for power plants, devices with flow through 2 Components and systems of power or process plants under operational and accident conditions FAW-T Testing and investigations on components and systems of power or process plants under operational and accident conditions 3 Process engineering systems FAW-T Passive autocatalytic recombiner (PAR) ignition tests within test vessel VB Type- and in-service testing on components of power plants FAW-T-3006 Performance tests and type tests of components for power plants for verification of the safety margin against loss-ofcoolant accidents 5 Diagnosis tests on components of power plants FAW-T Diagnosis tests on components of power plants Period of validity: to Translation - 2/5

3 Table 1: Underlying Typical Test Requirements (Flexible Accreditation) Test requirements Measurements *) Characteristic test methods Heat transfer, pressure loss, temperature distribution, critical heat flux on tubes of coal fired steam generator Limits of heat remocal for "In-" and "x-vessel Cooling" Functionality of spacers Sump sieve clogging and transportation phenomena Flow distribution in front of catalysts Investigations of accident scenarios: large break, small break, loss of residual heat removal system under shut down conditions, station blackout Behavior of discharge flow from borated water storage tank Boron mixing/boron distribution in the borated water storage tank Valve tests within a water circuit Discharge tests of safety valves Testing of control rod drive mechanisms Testing of core components Testing of components of power plants (e.g. pump sealings, in-core instrumentation nozzles, rupture discs) *) for measuring and test ranges (see table 2) current, voltage flow velocity distribution, vibrations, deposits, deformations deposits Flow velocities, concentrations, temperature distributions concentration, current, voltage, level velocity, acceleration, vibration, strain, force, current, voltage FAW-T-1001 FAW-T-2001 Period of validity: to Translation - 3/5

4 Test requirements Measurements *) Characteristic test methods Testing of all types of valves (e.g. safety valves, check valves, diaphragm valves ), actuators (e.g. electrical, solenoid, pneumatic, SIA ) and components (e.g. pumps, condensers ) in built-in situations Factory acceptance tests of new valves before delivery Tests of components within water/steam circuits such as safety valves, stop valves, check valves, pumps, level probes, sealings, rupture disks Determination of heat transfer, performance of heat exchangers Qualification tests of components of electro- and control technology under accident conditions Performance of tests for determination of critical heat flux on dummy fuel assemblies under forced and natural circulation, measurement of one- and twophase flow differential pressures Determination of pressure loss coefficients of valves and dummy fuel assemblies Investigations of accident scenarios of reactors Test of containment systems such as: venturi scrubber, H 2-recombinors and igniters, gas concentrations, humidity measuring systems force, torque current, voltage, force, vibration, acceleration, mechanical stress, power mass flow, steam quality force, torque, current, voltage, insulating resistance power differential pressure, mass flow level, steam quality, void separation efficiency, gas concentration FAW-T-2003 FAW-T-3010 NTCTC-G/2009/en/0064A FAW-T-3006 FAW-T-3021 FAW-T-3019 NGTT3/2005/de/0040B NTCTC-G/2009/de/0075 A FAW-T-3039 NTCTC-G/2006/de/0057 A NGTT3/2004/en/0013A *) for measuring and test ranges (see table 2) Period of validity: to Translation - 4/5

5 Table 2: Measurements and measuring ranges Measurement Measuring range Temperature -70 C 1,100 C Pressure 7.5 Pa - 40 MPa Volume flow m³/h - 100,000 m³/h Mass flow 1, kg/s kg/h - 4,000 kg/s Force 1 N - 10,000 kn Torque 1 Nm - 50,000 Nm Length 1 µm - 10 m Velocity 0.1 mm/s m/s Acceleration 0.05 g g Current 1 µa - 85,000 A Voltage 1 mv - 4 kv lectrical power up to 20 MW ffective power up to 420 kw Weight g - 5,000 kg Insulating resistance 50 kω TΩ (10 V - 1,090 V) Resistance 0,01 Ω MΩ lectric charge 10 pc nc Humidity 5 % r.f % r.f. Abbreviations used: FAW-T-1xxx FAW-T-2xxx FAW-T-3xxx IC ISO NGTT3 NTCTC-G rlangen site rlangen site arlstein site International lectrotechnical Commission International Organization for Standardization Division related work- instruction of the Framatome GmbH Division related work- instruction of the Framatome GmbH Period of validity: to Translation - 5/5