Online data sheet MCS300P HW PROCESS SOLUTIONS

Size: px
Start display at page:

Download "Online data sheet MCS300P HW PROCESS SOLUTIONS"

Transcription

1 Online data sheet MCS300P HW

2 A B C D E F H I J K L M N O P Q R S T Ordering information Type MCS300P HW Part no. On request The exact device specifications and performance data of the product may deviate from the information provided here, and depend on the application in which the product is being used and the relevant customer specifications. Our regional sales organization will help you to select the optimum device configuration. Other models and accessories Product description The MCS300P HW is a hot/extractive analyzer system for measurement of gases. It measures IRor VIS-active components with variable measuring ranges for monitoring and controlling of combustion and flue gas conditioning. The heated system components prevent a temperature drop below the water and acid dewpoint. This results in lower maintenance and higher reliablity and long-time stablity of the system, also under rugged and demanding conditions. Automatic adjustment functions, easy operation concept and modern communication protocols results in a quick and easy integration into a local control system network. At a glance Simultaneous measurement of up to 6 components plus O 2 Sample flow control and sample gas pressure measurement Temperature of heated system components up to 220 C Automatic sample point switching for up to 8 sample points (option) Automatic adjustment of zero and span point Integrated adjustment unit without span gas (option) Extended operation via PC and software Flexible I/O modules Your benefits Economic, automatic adjustment without expensive test gases Easy remote control by integration in existing networks Automatic control of the complete measuring system and probe Low maintenance and reliable due to hot measurement In combination with probe SCP3000 also for measurements at high dust loads and high temperatures Short response time due to high sample gas flow 2 ANALYZER SOLUTIONS SICK Online data sheet :48:09 Subject to change without notice

3 Fields of application Monitoring of flue gas conditioning in waste or sewage sludge incinerators Monitoring of the scrubber in flue gas conditioning Measurement directly at the kiln inlet in cement plants Detailed technical data System Measured values CO, CO 2, HCl, H 2 O, NH 3, NO, NO 2, N 2 O, SO 2, O 2 Measurement principles Gas flow rate Measuring ranges CO CO 2 HCl H 2 O NH 3 NO NO 2 N 2 O O 2 SO 2 Interference filter correlation, Gas filter correlation, Zirconium dioxide sensor 150 l/h l/h ppm / Vol.-% Vol.-% / Vol.-% ppm / ,000 ppm Vol.-% / Vol.-% ppm / ,000 ppm ppm / ,000 ppm ppm / ,000 ppm ppm / ,500 ppm Vol.-% / Vol.-% ppm / Vol.-% Other measuring ranges and components on request 2 measuring ranges per component Response time (t 90 ) Zero point drift Detection limit 150 s Depending on type and length of sample gas line IR: < 2 % of measuring range full scale per week 2 % of measuring range full scale Process temperature +1,300 C Depending on sampling probe Sample gas temperature +220 C Process pressure 800 hpa... 1,200 hpa Ambient temperature +5 C C Temperature change maximum ±10 C/h With cooling device: +5 C C Temperature change ±10 C/h maximum; other temperatures on request Ambient humidity 80 % Non-condensing Electrical safety Enclosure rating CE IP43 Versions with NO x -converter (option) Analog outputs Analog inputs 2 outputs: 0/ ma, 500 Ω Electrically isolated; additional outputs if using I/O modules (option) 2 inputs: 0/ ma, 100 Ω Electrically isolated; additional inputs if using I/O modules (option) :48:09 Online data sheet Subject to change without notice ANALYZER SOLUTIONS SICK 3

4 A B C D E F H I J K L M N O P Q R S T Digital outputs Digital inputs Interfaces and bus protocols Indication Input Operation Model Dimensions (W x H x D) Weight Corrective functions Test functions Ethernet Ethernet Ethernet 3 potential-free contacts: Additional outputs if using I/O modules 2 power relays: Electrically isolated; additional outputs if using I/O modules (option) 2 potential-free contacts: Additional inputs if using I/O modules Modbus TCP OPC SOPAS ET LC display Status LEDs: "Power", "Maintenance" and "Failure" Functional keys Via operating unit in the analyzer Two operating levels, one password-protected Application specific programs for system control Via software SOPAS ET Steel sheet cabinet 800 mm x 2,100 mm x 600 mm 300 kg Cross-sensitivity compensation of up to 6 interferents Internal adjustment unit (option) Automatic check cycle for zero and span point 4 ANALYZER SOLUTIONS SICK Online data sheet :48:09 Subject to change without notice

5 Dimensional drawing (Dimensions in mm (inch)) MCS300P HW system 2160 (85.04) 2100 (82.68) 600 (23.62) 800 (31.50) 550 (21.65) :48:09 Online data sheet Subject to change without notice ANALYZER SOLUTIONS SICK 5

6 Online data sheet SICK at a glance SICK is one of the leading manufacturers of intelligent sensors and sensor solutions for industrial applications. A unique range of products and services creates the perfect basis for controlling processes securely and efficiently, protecting individuals from accidents and preventing damage to the environment. We have extensive experience in a wide range of industries and understand their processes and requirements. With intelligent sensors, we can deliver exactly what our customers need. In application centers in Europe, Asia and North America, system solutions are tested and optimized in accordance with customer specifications. All this makes us a reliable supplier and development partner. Comprehensive services complete our offering: SICK LifeTime Services provide support throughout the machine life cycle and ensure safety and productivity. For us, that is Sensor Intelligence. Worldwide presence: Contacts and other locations SICK AG Waldkirch Germany