GD Specifications

Size: px
Start display at page:

Download "GD Specifications"

Transcription

1 GD1-10 Specifications

2 Information in this specification may be subject to change without notice. Please ensure you have the current version before beginning installation , Plan View 495 1, , Side View 530 Side View Front View P G P G min. 1,605 Rear View P = Power In G = Gas In OLERANCE = +/- 3mm min. to framing c 1,655 Fixing holes for M5 bolts - check on site Fire Installation - rim Sizes Confirm fixing holes on site prior to drilling COPYRIGH HIS DRAWING IS HE PROPERY OF he Fire Dept. Client: HE FIRE DEP. itle: GD1-10 FIREBOX DIMENSIONS GD Drawing No. Sheet of 07 Revision

3 c (clearance to back of opening) 520 min. 96 min. (wall framing) Shaded area Surround Detail 1 Plan View - Fire Insert Shaded area Non- lining shown shaded (clearance to top of opening) Surround Detail min. F.L. Shaded area Front View - Fire Insert Shaded area 520 min. See Mantel Detail min. Combustible min. 660 See Mantel Detail 4 (clearance to top of opening) Surround Detail 2 Surround Detail 3 F.L. Combustible min. Structure to support fire, design for 200kg load Varies 660 (clearance to top of opening) Surround Detail 2 Surround Detail 3 F.L. Cross Section - Fire Insert at Floor Level Cross Section - Fire Insert on Raised Plinth Plinth height can vary to suit COPYRIGH HIS DRAWING IS HE PROPERY OF he Fire Dept. Client: HE FIRE DEP. itle: CAVIY CLEARANCES GD1-10 GD Drawing No. Sheet 02 of 07 Revision

4 Combustible Non- wall lining 5 5mm gap to Non- wall lining 5 Hot air out - keep clear Combustible 5mm gap to Detail 1 - Plan View Fire Surround Detail 2 - op of Fire to Combustible Materials 5 Cool air in - keep clear 5mm gap to Combustible Non- wall lining Combustible mantel to shaded area only 45 0 (do not place mantel outside the shaded area) (top of fire) Front glass Detail 3 - Bottom of Fire to Floor Detail 4 - op of Fire to Combustible Mantel COPYRIGH HIS DRAWING IS HE PROPERY OF he Fire Dept. Client: HE FIRE DEP. itle: SURROUND DEAILS GD1-10 GD Drawing No. Sheet 03 of 07 Revision

5 600 Cowl Stainless steel spigot to underside of roof structure Casing cover / op flashing Spacers to maintain mm min. gap between flue pipe / casing / spigot Wall flashing in accordance with NZBC Roof Roof flashing in accordance with NZBC or Dektite Flashing No. 7 Flue to fire Hot air out External wall cowl Warm air Allow air flow from roof cavity out through casing cover Casing to In-line fan Flue to In-line fan Casing to fire Spigot wall plate Exterior wall Detail - Air Ventilation through Casing cover/ op flashing Flue components: 100mm dia. Flue 1mm dia. Casing 200mm dia. Spigot Dektite Flashing No. 7 Detail - Air Ventilation through Wall Flue components: 100mm dia. Flue 1mm dia. Casing 200mm dia. Spigot Flue components must be installed to AS/NZS5601 ruirements. mm clearance between flue and. Flue to be aduately supported at 2.4m crs Detail - In-Line Fan Ruires access hatch for maintenance Dektite Flashing No. 7 - Plan View COPYRIGH HIS DRAWING IS HE PROPERY OF he Fire Dept. Client: HE FIRE DEP. itle: VERICAL & HORIZONAL FLUE EXI DEAILS GD1-10 GD Drawing No. Sheet 04 of 07 Revision

6 In-Line Fan 0.2m min. to 13.5m max. Flue exit 0.5m min. to 13.8m max. Maximum total flue length 14m Exterior wall Flue components must be installed to AS/NZS5601 ruirements. mm clearance between flue and. Flue to be aduately supported at 2.4m crs. Horizontal Flue Combination GD1A 0.2m min. to 13.1m max. 0.2m min. to 13.1m max. In-Line Fan Flue exit 0.5m min. to 13.4m max. 0.2m min. to 13.1m max. Maximum total flue length 14m Flue components must be installed to AS/NZS5601 ruirements. mm clearance between flue and. Flue to be aduately supported at 2.4m crs. Horizontal Flue Combination GD1B COPYRIGH HIS DRAWING IS HE PROPERY OF he Fire Dept. Client: HE FIRE DEP. itle: HORIZONAL FLUE COMBINAION OPIONS GD1-10 GD Drawing No. Sheet 05 of 07 Revision

7 Flue exit 0.2m min. to 13.15m max. (underside of roof structure) Roof 0.5m min. to 12.95m max. 0.35m min. to 12.95m max. In-Line Fan Maximum total flue length 14m Flue components must be installed to AS/NZS5601 ruirements. mm clearance between flue and. Flue to be aduately supported at 2.4m crs. Vertical Flue Combination GD1C Flue exit 0.2m min. to 12.75m max. 0.2m min. to 12.75m max. (underside of roof structure) Roof 0.35m min. to 12.9m max. In-Line Fan 0.2m min. to 12.75m max. 0.5m min. to 13.05m max. Maximum total flue length 14m Flue components must be installed to AS/NZS5601 ruirements. mm clearance between flue and. Flue to be aduately supported at 2.4m crs. Vertical Flue Combination GD1D COPYRIGH HIS DRAWING IS HE PROPERY OF he Fire Dept. Client: HE FIRE DEP. itle: VERICAL FLUE COMBINAION OPIONS GD1-10 GD Drawing No. Sheet 06 of 07 Revision

8 or less More than min min. if clear within 3000 of flue top Increase as necessary until nothing within 3000 of flue top Any near by structure 3000 or less More than min Increase from 1000 min. until clear within 3000 of flue top Minimum Height of Flue System Exit Or as per AS/NZS 5601 Opening into a building S g f C b j n j Door h j Z h e P e d I M k k d a c g g See Note 1 Direction of discharge See Note 1 LEGEND: I = Mechanical air inlet M = Gas meter P = Electricity meter or fuse box S = Structure = Flue terminal Z = Fan-assisted appliance only Shading indicates prohibited area for flue terminals a = 200 g = 0 b = 300 h = 300 c = 300 j = 300 (at window) & 10 d = 1000 (fan-assisted appliance by the door) e = 0 k = 1000 f = 75 n = 0 NOES: 1 Where dimensions c, j or k cannot be achieved an uivalent horizontal distance measured diagonally from the nearest discharge point of the terminal to the opening may be deemed by the echnical Regulator to comply. Location of Flue erminals of Balanced Flue, Room-Sealed, Fan-Assisted or Outdoor Appliances o be read in conjunction with AS/NZS :2013 COPYRIGH HIS DRAWING IS HE PROPERY OF he Fire Dept. Client: HE FIRE DEP. itle: GD1-10 FLUE EXI CLEARANCES GD Drawing No. Sheet 07 of 07 Revision