Size : Ends : Min Temperature : Max Temperature : Matierials : Brass body

Size: px
Start display at page:

Download "Size : Ends : Min Temperature : Max Temperature : Matierials : Brass body"

Transcription

1 Size : Ends : Min Temperature : Max Temperature : Bore 15 and 20 Threaded male BSP 0 C ( for cold water type ) + 90 C ( for hot water type ) Max Pressure : 16 Bars Specifications : Single jet Rotating dial Dry dial Magnetic movement Matierials : Brass body Page 1 sur 7

2 SPECIFICATIONS : Single jet MID R100 for horizontal position and horizontal dial (respect the flow direction indicated by the arrow ) MID R50 for vertical position or horizontal position with vertical dial (respect the flow direction indicated by the arrow ) Rotating dry dial Magnetic movement Direct reading on 8 numerical rolls With lid Brass body USE : Water distribution Min and max temperature Ts : 0 C to 30 C for cold water type Ref.1701 Min and max temperature Ts : 30 C to 90 C for hot water type Ref.1702 Max Pressure Ps : 16 bars HEAD LOSS : Flow ( m3/h ) TYPICAL ERROR CURVE : Error in % Q1 : Min. flow Q2 : Transitional flow Q3 : Nominal flow Q4 : Max. flow Page 2 sur 7

3 RANGE : Cold water Ref.1701 Bore 15 and 20 Hot water Ref.1702 Bore 15 and 20 MATERIALS : Item Designation 1 Lid 2 Sealing ring 3 Transparent cup in PC 4 Holding gasket 5 Totalising mechanism 6 Seger 7 Sealng plate 8 Turbine 9 Pivot 10 Holding seal 11 Brass body 12 Strainer Page 3 sur 7

4 ACCESSORIES : Free nut water meter union with hole for filling on nut Male BSP o DN 15 F3/4"- M1/2" Ref o DN 15 F3/4"- M3/4" Ref o DN 20 F1" M3/4" Ref Plastic antifraud seal o DN 15 Ref o DN 20 Ref PVC pipe Male BSP ( waiting for water meter ) o DN 15, 110 mm long Ref o DN 20, 130 mm long Ref Brass pipe Male BSP ( waiting for water meter ) o DN 15, 110 mm long Ref Brass water meter stand o DN 15, 110 mm long Ref Page 4 sur 7

5 SIZE ( in mm ) : Ref. DN G 3/4" 1 L Ø B H h Weight (in Kg) Page 5 sur 7

6 TECHNICAL FEATURES ( according to MID ) : DN Max flow rate Q4 max ( m3/h) Nominal flow rate Q3 ( m3/h ) Min flow rate class MID R=100 Q1 with ± 5% error ( L/h ) Min flow rate class MID R=50 Q1 with ± 5% error ( L/h ) Transitional flow rate Class MID R=100 Q2 with ± 2% error ( L/h ) Transitional flow rate Class MID R=50 Q2 with ± 2% error ( L/h ) Min reading ( L ) Max reading ( m3 ) STANDARDS : Fabrication according to ISO 9001 : 2008 ICIM and IQNET DIRECTIVE 97/23/CE : Products excluded from directive ( article 1, 3.2 ) Approval certificate MID according to directive 2004/22/CE MID annex B French water agreement : A.C.S. N 11 ACC LY 067 Approval certificate Russian Federation GOST-R Approval certificate Ukrainian UKRSEPRO Approval food certificate TIFQ DM 174/2004 Threaded male BSP cylindrical according to ISO ADVICE : Our opinion and our advice are not guaranteed and SFERACO shall not be liable for the consequences of damages. The customer must check the right choice of the products with the real service conditions. Page 6 sur 7

7 INSTALLATION INSTRUCTIONS OF WATER METER BEFORE INSTALLATION : Pipe-line must be cleaned and free from residual of weldings,rubbish,shaving and every kind of extraneous materials. Pipe-line must be perfectly aligned and their support properly dimensioned so that there s no external constraint. It s recommended to use a water meter stand. When installing water meter on pipe-line, use fittings with flat span. To tighten the ends,use the appropriate tool. Use the right bolt tightening so that the ends won t be damaged. We suggest to place straight pipes before and after the water meter. Straight pipe must be length 5 times water meter DN. It s recommended to install a strainer before the water meter if there are some solid particles in the water. Install ball vales before and after the water meter, so to facilitate the possible water meter removal. We suggest to install no-return check valve after the water meter also. TESTS : During the tests under pressure, water meter must be removed to avoid overpressure risks. INSTALLATION Please make the water flow slowly to avoid water hammer. The meter pit shall be protected from flooding, rainwater and frost. INSTALLATION POSITIONS : The counter should be normally placed in an horizontal position The counter can be installed vertically with ascending flow or tilted without suffering any damage. It must be considered tough that in these cases the metering precision of the meter is going to be slightly altered. If necessary, the counter can be installed vertically with descending flow but the pipe should always be full of water in this case. NOTE: Never install the water meter in horizontal position with totalizer in upside down orientation. HORIZONTAL : Class MID R=100 Class MID R=50 ( Vertical dial assimilated to vertical position ) * : In vertical position, the metering precision of the meter is going to be slightly altered, and the pipe should always be full of water. VERTICAL* : Class MID R=50 Page 7 sur 7