AHERA/NESHAP ASBESTOS INSPECTION REPORT

Size: px
Start display at page:

Download "AHERA/NESHAP ASBESTOS INSPECTION REPORT"

Transcription

1 AHERA/NESHAP ASBESTOS INSPECTION REPORT CLIENT: Julie M. Wilkie City of Greenwood Assistant City Manager 520 Monument St., PO Box 40 Greenwood, SC (864) LOCATION: 230 Mineral Ave Greenwood, SC DATE OF INSPECTION: May 22, 2017 DATE OF REPORT: June 2, 2017 PREPARED BY: Michael D. Zavislak, NRCC-EAC, CHMM, CIH, PE (NC) & Robert Smith SUMMIT Engineering, Laboratory & Testing, P.C. (SUMMIT) 3575 Centre Circle Fort Mill, SC SUMMIT Job No

2 AHERA/NESHAP Asbestos Inspection SUMMIT Project No Mineral Ave, Greenwood, South Carolina June 2, 2017 AHERA/NESHAP ASBESTOS INSPECTION REPORT 230 Mineral Ave Greenwood, SC TABLE OF CONTENTS SECTION PAGE TABLE OF CONTENTS... i LIST OF APPENDICES... i 1.0 REPORT CERTIFICATION EXECUTIVE SUMMARY SUSPECT MATERIALS Flooring Roofing CONCLUSIONS AND RECOMMENDATIONS... 4 FIGURES 1.0 Site Location Map LIST OF APPENDICES A Analytical Results B Asbestos Inspector s License C SUMMIT Documentation i

3 AHERA/NESHAP Asbestos Inspection SUMMIT Project No Mineral Ave, Greenwood, South Carolina June 2, REPORT CERTIFICATION SUMMIT is pleased to provide environmental consulting services for City of Greenwood. Please contact this office at with any questions or comments regarding the findings submitted in this report. This document, entitled AHERA/NESHAP Asbestos Inspection Report, was prepared for City of Greenwood and the South Carolina Department of Health and Environmental Control (SCDHEC) with sound practices and procedures and in accordance with Asbestos Hazard Emergency Response Act (AHERA), Title II of the Toxic Substance Control Act (TSCA), SCDHEC Regulation , 40 CFR 61, and 40 CFR 763 for Asbestos Containing Materials (ACM) guidance. The results obtained by the work documented in this report fulfill the requirements of federal, state, and local regulations regarding Asbestos Containing Materials. June 2, 2017 Michael D. Zavislak, NRCC-EAC, CHMM, PE (NC) Date SC DHEC AHERA Asbestos Inspector No. BI Expiration Date: November 4, 2017 SC DHEC AHERA Asbestos Management Planner No. MP SC DHEC AHERA Asbestos Project Designer No. PD SC DHEC AHERA Asbestos Air Sampler No. AS SC DHEC AHERA Asbestos Supervisor No. SA E:\!Michael!\!SUMMIT!\ City of Greenwood\ Mineral Ave\Asbestos Inspection\Report Files\R - Asbestos Inspection.doc 1

4 AHERA/NESHAP Asbestos Inspection SUMMIT Project No Mineral Ave, Greenwood, South Carolina June 2, EXECUTIVE SUMMARY On May 22, 2017, SUMMIT Engineering, Laboratory & Testing, P.C. (SUMMIT) performed an AHERA/NESHAP Asbestos Inspection for City of Greenwood located at 230 Mineral Ave, Greenwood, SC. The purpose of this inspection was to investigate available records for the specification of asbestos containing material (ACM), inspect for suspect materials, sample and analyze suspect materials to test for asbestos, and assess the condition and location of the ACM and other characteristics of the structure. A homogeneous material is a material that appears to be uniform when properties such as age, color, and texture are compared. Four (4) homogeneous areas were sampled. The homogeneous areas are described in detail in section 3.0 of this report. The front room is fire-damaged. No Asbestos Containing Materials (ACMs) were found during the course of the asbestos inspection. E:\!Michael!\!SUMMIT!\ City of Greenwood\ Mineral Ave\Asbestos Inspection\Report Files\R - Asbestos Inspection.doc 2

5 AHERA/NESHAP Asbestos Inspection SUMMIT Project No Mineral Ave, Greenwood, South Carolina June 2, SUSPECT MATERIALS 3.1 Flooring The flooring appears to be in damaged condition with a low potential for damage. The material is non-friable and is classified as a miscellaneous material. The material was sampled and the results indicated that the material is not classified as Asbestos Containing Materials (ACM). The sample analysis of the material is enclosed in Appendix A. A detailed map showing the locations of the sampling locations can be found in the SUMMIT Documentation. 3.2 Roofing The roofing appears to be in damaged condition with a low potential for damage. The material is non-friable and is classified as a miscellaneous material. The material was sampled and the results indicated that the material is not classified as Asbestos Containing Materials (ACM). The sample analysis of the material is enclosed in Appendix A. A detailed map showing the locations of the sampling locations can be found in the SUMMIT Documentation. E:\!Michael!\!SUMMIT!\ City of Greenwood\ Mineral Ave\Asbestos Inspection\Report Files\R - Asbestos Inspection.doc 3

6 AHERA/NESHAP Asbestos Inspection SUMMIT Project No Mineral Ave, Greenwood, South Carolina June 2, CONCLUSIONS AND RECOMMENDATIONS On May 22, 2017, SUMMIT Engineering, Laboratory & Testing, P.C. (SUMMIT) performed a AHERA/NESHAP Asbestos Inspection for 230 Mineral Ave, Greenwood, SC. SUSPECT MATERIAL ACM (Y/N) FRIABLE (Y/N) AMOUNT (Square feet) Flooring N N 800 Roofing N N 1,000 No Asbestos Containing Materials (ACMs) were found during the course of the asbestos inspection. If the structure is to be renovated or demolished, a copy of this report and a notification of demolition or renovation forms must be submitted to The South Carolina Department of Health and Environmental Control (SCDHEC) at least ten working days prior to these activities taking place. Bidders are responsible for their own calculations and estimates of quantities. Actual quantities may be more or less than indicated. Though every effort was made to examine wall cavities and other areas for pipe insulation, spray-applied or trowel applied miscellaneous material or other miscellaneous materials and other Presumed Asbestos Containing Material (PACM), this survey and report only deals with accessible areas of the building. There may be additional inaccessible areas above ceiling, behind walls and below floors that become evident during demolition or renovation activities. If suspect materials are found, additional asbestos testing may be required. E:\!Michael!\!SUMMIT!\ City of Greenwood\ Mineral Ave\Asbestos Inspection\Report Files\R - Asbestos Inspection.doc 4

7 AHERA/NESHAP Asbestos Inspection SUMMIT Project No Mineral Ave, Greenwood, South Carolina June 2, 2017 FIGURES E:\!Michael!\!SUMMIT!\ City of Greenwood\ Mineral Ave\Asbestos Inspection\Report Files\R - Asbestos Inspection.doc

8 Figure 1 Site Location Map 230 Mineral Ave Greenwood, SC SUMMIT ELT, PC Project: E:\!Michael!\!SUMMIT!\ City of Greenwood\ Mineral Ave\Asbestos Inspection\Report Files\R - Figure 1 Site Map.doc

9 AHERA/NESHAP Asbestos Inspection SUMMIT Project No Mineral Ave, Greenwood, South Carolina June 2, 2017 APPENDIX A ANALYTICAL RESULTS E:\!Michael!\!SUMMIT!\ City of Greenwood\ Mineral Ave\Asbestos Inspection\Report Files\Appendix A.rtf

10 Asbestos Laboratory Report Prepared for SUMMIT Engineering, Laboratory & Testing, P.C. Project: 230 Mineral Summit #: Date Analyzed: 5/25/2017 Date Reported: 5/26/2017 Total Samples Analyzed: 10 # Samples >1% Asbestos: 0 Method of Analysis: EPA 600 / R93 / 116 Page 1 of 3

11 Summit Laboratories 3575 Centre Circle, Fort Mill, SC Phone: (704) Summit Order: SUMMIT Engineering, Laboratory & Testing, P.C Centre Circle Drive Fort Mill, SC Date Received: 5/23/2017 Date Analyzed: 5/25/2017 Date Reported: 5/26/2017 Project : 230 Mineral Asbestos Sample ID Description Appearance % Fibrous % Non-Fibrous % Asbestos F-1 Test Report: Asbestos Analysis of Bulk Material via EPA 600/R-93/116 Method using Polarized Light Microscopy F F-1-Flooring F-1-Mastic A F-2-Flooring F-2-Mastic A R R F F ENTRY WAY ENTRY WAY BATH BATH BATH BATH ROOFING ROOFING THROUGHOUT THROUGHOUT Gray,White Non-Fibrous Homogeneous Gray,White Non-Fibrous Homogeneous White Fibrous Homogeneous Brown Non-Fibrous Homogeneous White Fibrous Homogeneous Brown Non-Fibrous Homogeneous Black,Brown Fibrous Homogeneous Black,Brown Fibrous Homogeneous Brown,Tan Non-Fibrous Homogeneous Brown,Tan Non-Fibrous Homogeneous <1% Synthetic 100% Non-Fibrous (other) <1% Synthetic 100% Non-Fibrous (other) 15% Cellulose 1% Glass 84% Non-Fibrous (other) <1% Cellulose 100% Non-Fibrous (other) 15% Cellulose 1% Glass Non-Asbestos 84% Non-Fibrous (other) <1% Cellulose 100% Non-Fibrous (other) 5% Glass 95% Non-Fibrous (other) 5% Glass 95% Non-Fibrous (other) <1% Synthetic 100% Non-Fibrous (other) <1% Synthetic 100% Non-Fibrous (other) Analyst(s): Chris Estes Page 2 of 3

12 METHOD: EPA 600 / R93 / 116 For samples easily separated into homogeneous layers, each component will be analyzed separately. The sample may not be representative of the larger material in question. Interpretation and use of test results are the responsibility of the client. Due to the limitations of the EPA 600 Method, nonfriable organically bound materials (NOBs) such as vinyl floor tiles, mastic and roofing can be difficult to analyze by PLM. Reanalysis by Transmission Electron Microscopy (TEM) to verify results of <1% or None Detect for these materials is recommended. This sheet may not be reproduced except with permission from Summit Laboratories. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. Analyst(s): Chris Estes Approved By: Michael Zavislak, Approved Signatory NVLAP Lab Code Summit Laboratories, 3575 Centre Circle, Fort Mill, SC 29715, Phone: (704) Page 3 of 3 This is the last page of the report

13

14

15 Customer: Project: Summit Engineering, Laboratory & Testing, P.C Centre Circle Drive Fort Mill, SC Mineral/ Bulk Asbestos Analysis by Transmission Electron Microscopy Semi-Quantitative Chatfield SOP Rev. 1 Attn: Michael Zavislak Robert Smith Lab Order ID: Analysis ID: Date Received: Date Reported: _TBS 5/25/2017 6/1/2017 Sample ID Lab Sample ID Description Lab Notes Organic Acid Sol. Asbestos (Wt. %) (Wt. %) (Wt. %) LCL-UCL (Wt. %) F-3 Entry way 22% TBS_1 F-3 Bath/flooring & mastic 37% TBS_2 R-3 Roofing 3.0% TBS_3 R-3 Throughout 32% TBS_4 Disclaimer: This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Russell Shelton (4) T-F-010 r15 1/15/2018 tem_ Analyst Approved Signatory Scientific Analytical Institute, Inc Dundas Dr. Greensboro, NC (336) Page 1 of 1

16 Company Contact Information Scientific Analytical Institute 4604 Dundas Dr. Greensboro, Ne Phone: Fax: Company: Summit Engineering, Laboratory & Testing, P.C. Contact: Michael Zavislak Address: 3575 Centre Circle Phone 0: Fort Mill, SC Fax 0: 0: Billing/Invoice Information Turn Around Times - Company: Summit Engineering, Laboratory & Testing, P.C. 90 Min Hours 0 Contact: Michael Zavislak 3 Hours 0 72 Hours 0 Address: 3575 Centre Circle 6 Hours 0 96 Hours 0 Fort Mill, SC Hours Hours ~ 24 Hours Hours 0 PO Number:, Project NamelNumber: 1.30 Please cc Robert Smith rsmith@summit-companies.com with results Lab Use Only j Lab Order ro -L.D>..~.-!::::.---=--=~ Client Code: _ Asbestos Test Types PLM EPA 600/R-93/116 (PLM) Positive stop 0 PLM Point Count 400 (PT4) 0 PLM Point Count 1000 (PTM) 0 PCM NIOSH 7400-A Rules (PCM) 0 B Rules (PCB) 0 TWA (PTA) 0 TEM AHERA (AHE) 0 TEM Level II (L11) 0 TEM NIOSH 7402 (TNI) 0 TEM Bulk Qualitative (TBL) 0 TEM Bulk Chatfield (TBS) [Yf TEM Bulk Quantitative (TBQ) 0 TEM Wipe ASTM D TEM Microvac ASTM D TEM Water EPA (TWI) 0 Other: 0 Sample ID # Volume/Area Comments F-3 F-3 ~-3 F ~ E(\~J Wa...v \)~~ / t==\o~, ', r'\.c.. ~ M,,-sA--, ( \AC>6~', "-,, T'n ("0<..1 ~~'l ~ ~...J Total # of Samples ~ Accepted RejeCted 0

17 AHERA/NESHAP Asbestos Inspection SUMMIT Project No Mineral Ave, Greenwood, South Carolina June 2, 2017 APPENDIX B INSPECTOR S LICENSES E:\!Michael!\!SUMMIT!\ City of Greenwood\ Mineral Ave\Asbestos Inspection\Report Files\Appendix B.rtf

18 SGDHEltrTSSUED Asbestos ld Card Michael Zavislak CONSULTPD PD.OOO92 AIRSAMPLER AS.O0296 SUPERAHERA SA-OI5'I5 GONSULTIIP MP.OO.I04 consultbt Bl E\piration Date,l,llo4l,l7 11t03t17 1,uou,t7,l,llo2l,l7 1,,1o2r,7

19 AHERA/NESHAP Asbestos Inspection SUMMIT Project No Mineral Ave, Greenwood, South Carolina June 2, 2017 APPENDIX C SUMMIT DOCUMENTATION E:\!Michael!\!SUMMIT!\ City of Greenwood\ Mineral Ave\Asbestos Inspection\Report Files\Appendix C.rtf

20 AHERA/NESHAP Asbestos Inspection SUMMIT Project No Mineral Ave, Greenwood, South Carolina June 2, 2017 SITE PHOTOGRAPHS Front of structure. Photo showing all flooring types. E:\!Michael!\!SUMMIT!\ City of Greenwood\ Mineral Ave\Asbestos Inspection\Report Files\R-Ph I - Site Photographs.doc 1

21