Eutech 2700 Series. Bench Meters

Size: px
Start display at page:

Download "Eutech 2700 Series. Bench Meters"

Transcription

1 Eutech 2700 Series Bench Meters

2 Comprehensive Backlit Display All Measurements Include Temperature Display Up To 500 Point Memory With Date Time Stamp For GLP Output Data To Printer Or PC Detachable Electrode Holder Compact Footprint Saves Valuable Bench Space Custom Setup 3-Year Warranty Password Protection, Audible Alarms, Electrode Data, And Much More! Calibration Report view or print detailed electrode data Stability Display faded out and then turns solid when stable Large Informative Display with bright backlight Integrated Electrode Holder can be used on either side Splashproof Housing & Keypad protects against incidental spills Non-Skid Pads hold meter steady during operation CyberComm Software available Slide-Out Calibration Guide for quick referencing Meter Features ph 2700 ION 2700 CON 2700 DO 2700 PC 2700 ph & mv ION Temperature Conductivity & TDS Dissolved Oxygen BOD Salinity Resistivity Memory 500 data sets Power Requirements 9 V DC adapter, 1.3 A (100/240 VAC, SMPS) Dimension ; Weight Meter: 17.5 (L) x 15.5 (W) x 6.9 (H) cm ; 650 g ; Boxed: 30.8 (L) x 23.5 (W) x 12.4 (H) cm ; 1800 g page 02

3 Conductivity / Total Dissolved Solids / Salinity / Resistivity / Temperature Featuring auto-standardization, auto-calibration and auto-ranging capabilities, the Eutech CON 2700 accepts 2-cell and 4-cell electrodes, allowing a broad range of measurement at up to ±1 % full scale accuracy. Meter comes with a multi data screen that shows Conductivity readings, temperature, electrode status, calibration points, date and time all at once. constant value of your electrodes with the press of a button GLP compliance Applications: Dissolved Oxygen / BOD / Temperature Designed for optimal performance and versatility, the DO 2700 come with intuitive, advance set-up options for extensive user-customization at an affordable price! Meter comes with self-stirring probe and bi-directional RS232 ideal for BOD and other Dissolved Oxygen applications in the laboratory. sensitivity during low oxygen levels Barometric Pressure Compensation GLP compliance Applications: page 04

4 Bench 2700 Series ph/ion Bench Meters ph 2700 ION 2700 Warranty three years of warranty against manufacturing defects for our meters, and six months for our electrodes. Dissolved Oxygen Bench Meter DO 2700 ph ORP ION Temperature 0 to ph 0.1 / 0.01 / ph ±0.002 ph + 1 LSD Buffer Sets Rel. mv 0.1 mv ±0.2 mv Concentration to ppm (±2000 mv) 2 or 3 digits (monovalent) ; (divalent) 2 to 8 (Meter) 0.0 to ºC / 32.0 to ºF 0.1 ºC / 0.1 ºF ±0.3 ºC / ±0.5 ºF Compensation A 0.00 to mg/l Dissolved Oxygen 0.01 mg/l ± % Saturation Of Oxygen Salinity Correction 0 to 50.0 ppt 0.1 ppt Barometric 450 to 825 mmhg (automatic) Pressure 1 mmhg Correction Method 0.0 to 50.0 ºC / 32.0 to ºF Temperature 0.1 ºC / 0.1 ºF ±0.3 º C / ±0.5 º F Multi-Parameter Bench Meter PC 2700 Conductivity TDS Salinity Resistivity Temperature Conductivity Bench Meter CON μs to ms 0.01 / 0.1 μs ; / 0.01 / 0.1 ms ± Cell Constant to (Depending On TDS Factor) ppm to 500 ppt 0.0 to 80.0 ppt Ω to 20.0 MΩ 0.01 / 0.1 Ω ; / 0.1 kω ; 0.01 MΩ (Meter) 0.0 to ºC / 32.0 to ºF 0.1 º C / 0.1 ºF ±0.3 º C / ±0.5 º F Coefficient (Per ºC) Normalization 15.0 to 30.0 ºC / 59.0 to 86.0 ºF Compensation A ph ORP ION Conductivity TDS Salinity Resistivity Temperature 0.1 / 0.01 / ph ±0.002 ph + 1 LSD Buffer Sets Rel. mv 0.1 mv ±0.2 mv Concentration to ppm (±2000 mv) 2 or 3 digits 2 to µs to ms 0.01 / 0.1 μs ; / 0.01 / 0.1 ms ± Cell Constant to (Depending On TDS Factor) ppm to 500 ppt 0.0 to 80.0 ppt Ω to 20.0 MΩ 0.01 / 0.1 Ω ; / 0.1 kω ; 0.01 MΩ (Meter) 0.0 to ºC / 32.0 to ºF 0.1 º C / 0.1 º F ±0.3 º C / ±0.5 º F Coefficient (Per ºC) Normalization 15.0 to 30.0 ºC / 59.0 to 86.0 ºF Compensation A page 06

5 Bench 2700 Series Meters ph ECPH270042GS 01X ph ECPH270040S 01X ION ECION270042GS 01X ION ECION270040S 01X CON ECCON270043S 01X DO ECDO X PC ECPC270043S 01X ph ECFG B 93X ORP ECFC79602R01B 01X CON CONSEN9501D 01X Connector, CON CONSEN9201D 01X DO EC620SSP 01X TEMP PH5TEMB01P 01X x 3 mm Shaft, 60X X SMPS, 100/240 VAC, 9 V, 6 W Power Adapter 01X X EC637DOM EC637DOM Membrane Caps, Polishing Disk 30X X X X ECMICROPRNTR01 01X Paper And A 110/120 VAC Power Adapter ECMICROPRNTR02 01X Paper And A 220/230 VAC Power Adapter ECADPTRM9M25 09X (480 ml Per Bottle) ph ECBU1BT 01X ph ECBU4BT 01X ph ECBU686BT 01X ph ECBU7BT 01X ph ECBU918BT 01X ph ECBU10BT 01X ph ECBU12BT 01X ph ECDPCBT 01X Protein Cleaning Solution For ph ECRE005 01X ph 01X X Chloride, 60 ml ORP ECORPPRE 01X ORP ECORPQUIN 01X (255 mv, ±15 25 ºC) Solution ORP ECORPQUIN086 01X (86 mv) Solution CON ECCON84BT 01X μs Conductivity CON ECCON1413BT 01X μs Conductivity CON ECCON1288BT 01X ms Conductivity CON ECCON1118BT 01X ms Conductivity TDS EC442300BT 01X ppm 442 Standard Calibration Solution TDS EC BT 01X ppm 442 Standard Calibration Solution TDS EC BT 01X ppm 442 Standard Calibration Solution Salinity ECNACL5PPT 01X Salinity ECNACL25PPT 01X Salinity ECNACL45PPT 01X Storage ECRE005 01X page

6 World-Wide Sales and Service Support sales and service support for all its products through its network of international distributors. Contact us at for details of your nearest distributor. Asia Pacific (Head Office) Eutech Instruments Pte Ltd North & South America OAKTON Instruments Europe Eutech Instruments Europe B.V. China Thermo Fisher Scientific Shanghai , China India Thermo Fisher Scientific Distributed by: 2006 & 2007 Awarded in 2001 & 2003 BEN 08X /10 Rev 0