1 GREEN DRAIN: Product Details -One-Way Valve providing 360 flow that meets all plumbing codes (UPC, IPC, and IRC). -Tested and certified by IAPMO, ICC-ES, and in compliance with ASSE 1072 Standard. -UV resistant ABS housing with injection molded silicone resistant to high temperatures and all bleaches, enzymes, and cleaners. -Simple press fit installation requiring no tools, fasteners, or adhesives. -Easy to remove for inspection and regular maintenance. -Ideal for retro-fit and new construction, in both commercial and residential applications. -Stops all gases, odors, and bugs from exiting floor drains. -Serves as a preventative solution of potential diseases originating from drainage systems. -Aides in water conservation by reducing evaporation and the need for retaining water in floor drain traps. GREEN DRAIN is a long term protection tool for drainage systems, the protection of public health, and general peace of mind. Green Drains SA FPT Building D Berth, South Arm, Cape Town South Africa (0) info@greendrains.co.za

2 The Ultimate Security System for Your Drains WHY IT S NEEDED: CDC, WHO & ICT, FACTS In the United States, the Centers for Disease Control and Prevention estimated roughly 1.7 million hospitalassociated infections (HAI s), from all types of microorganisms, including bacteria and fungi combined, cause or contribute to 99,000 deaths each year. *These infections add anywhere from $4.5 $5.7 billion per year to patient care costs.* THE PROBLEM: Every year there are more than 1 billion cases and over 1 million deaths globally from vector borne Zoonotic Diseases such as the Zika Virus, Malaria, Dengue, Lyme disease, Plague, West Nile Virus, Schistosomiasis, Human African Trypanosomiasis, Leishmaniosis, Chagas Disease, Yellow Fever, Japanese Encephalitis and Onchocerciasis. Filariasis may also reach man simply by being carried by flies or cockroaches via drainage. Thus, unlined open drains might become particularly dangerous transmission sites. It is at such sites that excreta disposal and human water contacts might occur in a concentrated and uncontrolled form. VECTOR BORNE DISEASES are illnesses caused by pathogens and parasites in human populations. Pathogen infected vectors represent an immediate threat, but even uninfected arthropods that escape can establish populations that subsequently transmit pathogens. Plumbing systems, along with open and exposed drains are potential sources for contamination that provide a hospitable habitat for waterborne pathogens, especially for Legionella. Legionella poses the most consistent threat in the healthcare setting. *KEY FACTS* Vector borne diseases account for more than 17% of all infectious diseases, causing more than 1 million deaths annually. More than 2.5 billion people in over 100 countries are at risk of contracting dengue alone. Malaria causes more than 600,000 deaths every year globally, most of them children under 5 years of age. Other diseases such as Chagas disease, leishmaniosis and schistosomiasis affect hundreds of millions of people worldwide. Many of these diseases are preventable through informed protective measures.

3 HOSPITAL FACILITIES & PRACTICES SHOULD MINIMIZE OR ELIMINATE THE ESCAPE OF ARTHROPODS AND PATHOGENS, PROTECT PATIENTS AND PROTECT PERSONNEL WHO WORK IN THE FACILITY. ZIKA VIRUS: Protection against mosquito bites is a key measure to prevent Zika virus infection. It is important to cover, empty or clean potential mosquito breeding sites in and around Healthcare Facilities, such as open drains. DANGEROUS SOIL EMISSIONS/GREENHOUSE GASSES: Radon (odorless and not visible) Methane (Contaminants from previous uses of the site) Pesticides Carbon Dioxide/Nitrous Oxide/Carbon Monoxide Solvent odors/gasoline (Leakage from underground fuel tanks) THE SOLUTION: Green Drain Green Drain reduces exposure to hazardous sewer gases and deadly HAI s in the workplace. It is an ecofriendly, preventative action that will lead to improved outcomes for worker & patient health, while exceeding the lifespan of traditional chemical applicants that harm the environment. Green Drain DRASTICALLY MINIMIZES THE RISK OF MULTIPLE, DEADLY HAI S. ELIMINATES: The threat of disease carrying pests that hide in your drains. (I.e. Drain Flies, Cockroach's, Fruit Flies, Silver Fish) The need to pour pesticides, chemical applicants and deodorizers down the drain. REDUCES: The risk of harmful sewer gasses intruding your facility through drain lines. Costly chemical expenditures. Plumbing related call outs. Exterminator related call outs and call backs. Timely drain maintenance by Facility Staff and Plumbers. Sewer load. The chemical impact on our oceans and environment. CONSERVES: Water and water related expenses by eliminating the need for trap primers. Time and energy. CONCLUSIONS: Laboratory research with arthropod vectors of vertebrate disease is essential for an improved understanding of the role of the vector in pathogen transmission and for development of enhanced disease prevention strategies. GREEN DRAIN WILL GIVE YOU THE PEACE OF MIND KNOWING THAT YOUR FACILITY S DRAINAGE SYSTEM IS PROTECTED!

4 waterless trap for floor drains Drain Protection Drainage technology is an area that has evolved very little since the advent of modern plumbing. However, buildings are getting bigger and the volume of matter we now push through these pipes are stressing the pipes out. The volume of drainage blockages has increased. Waste disposals and macerators are flushing solids. Commercial kitchens are washing away fats and fat solids. The pipes haven t increased in size, but the volume of content flowing through them has. Many buildings are also going green. Low flush toilets are installed. Water-saving devices on taps, showers and even energy efficient boilers are installed. Going Green ignores the original design of modern plumbing. Gravity and WATER push content through the pipes. When you reduce the water in a drain pipe and increase the content, the following happens: Blockages This leads to back-ups, flooding, drain flies and more infiltrating the living/work space through the drains. Dry Traps This causes the airflow to reverse direction instead of going down the drain it moves into the living/work area. Germs spread. It can lead to pathogen spread. Viruses such as NORO and SARS can spread quickly through the pipes and out the drains. Sewer Smells When the airflow reverses, sewer gas odors travel back into the living/work space through the drains. Sewer gas contains highly toxic substances such as hydrogen sulfide and ammonia. These gases are extremely flammable and exposure can cause headaches, nausea, dizziness and irritation to the eyes and respiratory tract. Green Drain, Inc. manufactures an economical Drain Trap Seal Device that allows water to flow down the drain while preventing Pests, Odors, or Harmful Gases/ Pathogens from infiltrating the living or work space. +27(0) Strand Crt, Suite #101 Naples, FL greendrains.com

5 waterless trap for floor drains Drain Fly Infiltration Drain flies appear in homes, rest rooms of commercial buildings, sewage disposal plants and agricultural facilities that handle moist animal waste. Restaurants, schools and other public buildings may be avoided when drain flies are a nuisance. Bronchial asthma can be caused by inhaling fragments and dust of dead flies. Since these flies originate in filthy conditions, there is the possibility of physical transmission of microbes of human health concern. Drain flies can carry bacteria and other microorganisms from egg-laying sites to food and surfaces that come in contact with food. Life Cycle Drain fly larvae grow and feed in polluted, shallow water or in highly moist organic solids prevalent in drains. The life cycle of drain flies can be completed in one to three weeks. Adults live about two weeks, with old ones dying and new ones emerging. Prevention The most effective way to prevent drain fly infestations is to eliminate their breeding places. Inside buildings, this would include cleaning the drain pipes, drain traps and other plumbing system components in an attempt to eliminate the bacterial scum (gelatinous rotting, organic matter) that regularly forms on the surfaces of plumbing. Pesticide Treatments There are no insecticides registered for use in drains or sewage systems, as they can cause major damage of sewer and sanitation systems. In most cases, the larvae seem to be resistant to such treatments. The Green Drain can help to prevent drain fly infiltration and potentially fatal cross contamination and infection spread caused by unprotected drains. The Green Drain is an economical Drain Trap Seal Device that allows water to flow down the drain while preventing Pests, Odors, and Harmful Gases/Pathogens from infiltrating the living or work space. +27(0) FPT Building D Berth, South Arm, Cape Town South Africa 8001 greendrains.co.za

6 waterless trap for floor drains Harmful Biologic Aerosols It is widely established that drains are reservoirs for microbes and antibiotic residues. It is also clear that microbes in drains and pipes adhere to the surfaces of drains and drainage pipes as microbial biofilms, creating a complex ecosystem of different microbes that are fed by organic and inorganic matter. Drains act as cradles to the emergence of bacteria armed with abilities to resist multiple antibiotics. The development of resistance is probably enhanced at hospitals due to the fact that more bacteria and more antibiotics are flushed down the drains due to the very nature of hospitals constantly caring for numerous different patients that are ill and treated with antibiotics. Thus, biofilm in building drains, not properly maintained, have the potential of spreading even more resistant bacteria. Numerous studies stress the importance of a physical barrier between drainage systems and surroundings. As shown in the SARS outbreak at Amoy Gardens, harmful biologic aerosols can enter the ventilation system from exposed drains and be spread to all the other connected rooms igniting a fearsome spread. It is essential that drainage systems must be completely tight and intact where openings have physical barriers. The Green Drain can help to prevent potentially fatal cross contamination and infection spread caused by unprotected drains. The Green Drain is an economical Drain Trap Seal Device that allows water to flow down the drain while preventing Pests, Odors, and Harmful Gases/Pathogens from infiltrating the living or work space. +27(0) FPT Building D Berth, South Arm, Cape Town South Africa 8001 greendrains.co.za

7 waterless trap for floor drains Sewer Gas Infiltration Sewer gas is a complex mixture of toxic and nontoxic gases that can be present at varying levels depending upon the source. It is formed during the decay of household and industrial waste. Highly toxic components of sewer gas include hydrogen sulfide and ammonia. Sewer gas also contains methane, carbon dioxide, sulfur dioxide, and nitrous oxides. In addition, chlorine bleaches, industrial solvents, and gasoline are frequently present in municipal and privately owned sewage treatment systems. The principal risks and effects associated with exposure are: Hydrogen Sulfide Poisoning. Exposure to low levels of hydrogen sulfide causes irritation of the eyes and respiratory tract. Other symptoms include nervousness, dizziness, nausea, headache, and drowsiness. This gas smells like rotten eggs, even at extremely low concentrations. Exposure to high concentrations can interfere with the sense of smell, making this warning signal unreliable. At extremely high levels, hydrogen sulfide can cause immediate loss of consciousness and death. Asphyxiation. High concentrations of methane in en closed areas can lead to suffocation, as large amounts of methane will decrease the amount of oxygen in the air. The effects of oxygen deficiency include headache, nausea, dizziness and unconsciousness. At very low oxygen concentrations (<12%), unconsciousness and death may occur very quickly and without warning. Sewer gas diffuses and mixes with indoor air, and will be most concentrated where it is entering the home. It can accumulate in basements. Explosion and Fire. Methane and hydrogen sulfide are flammable and highly explosive. The Green Drain can help to prevent sewer gas infiltration and potentially fatal cross contamination and infection spread caused by unprotected drains. The Green Drain is an economical Drain Trap Seal Device that allows water to flow down the drain while preventing Pests, Odors, and Harmful Gases/Pathogens from infiltrating the living or work space. +27(0) FPT Building D Berth, South Arm, Cape Town South Africa 8001 greendrains.co.za

8 waterless trap for floor drains Radon Gas Infiltration Radon is an odorless radioactive gas that results from the natural breakdown of uranium in soil. Uranium is present in most of the soil and rock around the world. It is typically concentrated in areas with lots of granite, shale, phosphate and pitchblende. The gas is a deadly carcinogen, accounting for over 20,000 deaths annually in North America. Studies show that sealing the sump and the floor drain eliminates the major source of radon infiltration. Radon gas comes from the decay products of uranium in the ground beneath buildings. It can seep in through cracks, sumps, joints, floor drains or other tiny openings in foundations. Radon gas emits radioactive particles that can be inhaled into the lungs. The adverse health effect lung cancer may not be produced immediately. An estimated 21,800 people die annually from radonrelated lung cancer. Radon is invisible, odorless, and tasteless. One in 15 houses have elevated radon levels; however, in some states it is over 50 to 70% of homes. Elevated radon levels have been discovered in every state in our nation. The USEPA estimates as many as 8 million homes throughout the country have elevated levels of radon. Over 70,000 classrooms have radon levels above the EPA action level. Fast Facts RADON - the second leading cause of lung cancer. RADON - is invisible, odorless, and tasteless. RADON - estimated 23,000 deaths yearly. SURGEON GENERAL S WARNING: Radon causes lung cancer. The Green Drain can help to prevent harmful radon gas infiltration through unprotected drains. The Green Drain is an economical Drain Trap Seal Device that allows water to flow down the drain while preventing Pests, Odors, and Harmful Gases/Pathogens from infiltrating the living or work space. +27(0) FPT Building D Berth, South Arm, Cape Town South Africa 8001 greendrains.co.za

9 waterless trap for floor drains Specifications: Series inline floor drain trap seal with UV resistant ABS plastic frame, silicone rubber sealing flapper and four flexible sealing ribs. Tested and certified to the ASSE 1072 Standard and listed with IAPMO and I.C.C. Specify connection size (2 (51MM), 3 (76mm), 3 1/2 (89mm) or 4 (102mm)) Function: Used in the outlet connections of floor drain bodies, or the inside of floor drain strainers to seal the opening to prevent odors, sewer gases, and insects from entering up through the floor drain grate. The Green Drain s four flexible silicone sealing ribs ensure easy installation into openings that have variations in size. The Green Drain will open to allow drainage and close when there is no water flow. The Green Drain can be used in either new construction or retro-fit applications where trap primers were never installed. Prevents the following from entering through the top of floor drains: Odors and sewer/radon gases Insects and harmful pathogen spread DEVICE SIZE FLOW RATE MODEL NUMBER GD102 GD103 GD1035 GD104 A PIPE SIZE INCH (mm) 2 (51mm) 3 (76mm) 3 1/2 (89mm) 4 (102mm) B HEIGHT INCH (mm) 2 (51mm) 2 (51mm) 2 (51mm) 2 (51mm) L/M GPM A GD104 GD103 B SILICON SEALING FLAPPER GD1035 GD102 SILICON GASKET FLEXES.100 TO FIT DIAMETER BOTTOM OF BODY TOP OF STRAINER U.S. Patent #7,900, (0) FPT Building D Berth, South Arm, Cape Town South Africa 8001 greendrains.co.za

10 waterless trap for floor drains Prevents Drain Odors Pest Infiltration Sewer/Radon Gas Infiltration Harmful Biologic Aerosols Product Features One way drain valve Ease of installation Does not impair flow rate Product Benefits Increases Indoor Air Quality Protects the Public Health Green Technology Helps in LEED Certification Does not impair plumbing maintenance Provides sewage back-flow protection Universal Plumbing Code Certified +27(0) FPT Building D Berth, South Arm, Cape Town South Africa 8001 greendrains.co.za

11 IAPMO Research and Testing, Inc. is a product certification body which tests and inspects samples taken from the supplier's stock or from the market or a combination of both to verify compliance to the requirements of applicable codes and standards. This activity is coupled with periodic surveillance of the supplier's factory and warehouses as well as the assessment of the supplier's Quality Assurance System. This listing is subject to the conditions set forth in the characteristics below and is not to be construed as any recommendation, assurance or guarantee by IAPMO Research and Testing, Inc. of the product acceptance by Authorities Having Jurisdiction. The most updated information on this Certificate of Listing is available online at pld.iapmo.org Effective Date: July 2018 Void After: July 2019 Product: Floor Drain Trap Seal Protection Devices File No Issued To: Green Drain Inc Kenton Drive #203b Cornelius, NC Identification: Each device shall be permanently and legibly marked with the manufacturer's name or trademark and the application designation (per Table 2 of ASSE ). Product shall also bear the UPC certification mark. Packaging shall bear the manufacturer's name or trademark, model number or description of the device, rating for type of floor, rated for grease-laden waste (if applicable), and the floor drain size. Characteristics: Barrier type floor drain trap seal protection devices. Installation instructions shall not state or imply that the device may be used in lieu of a trap primer. Product to be installed with other IAPMO R&T listed fittings, in accordance with the manufacturer's instructions, and the requirements of the latest edition of the Uniform Plumbing Code. Products listed on this certificate have been tested by an IAPMO R&T recognized laboratory. This recognition has been granted based upon the laboratory's compliance to the applicable requirements of ISO/IEC Products are in compliance with the following standard(s): This listing period is based upon the last date of the month indicated on the Effective Date and Void After Date shown above. Any change in material, manufacturing process, marking or design without having first obtained the approval of the Product Certification Committee, or any evidence of non-compliance with applicable codes and standards or of inferior workmanship, may be deemed sufficient cause for revocation of this listing. Production of or reference to this form for advertising purposes may be made only by specific written permission of IAPMO Research and Testing, Inc. Any alteration of this certificate could be grounds for revocation of the listing. This document shall be reproduced in its entirety.

12 Void After: July 2019 Product: Floor Drain Trap Seal Protection Devices File No Issued To: Green Drain Inc ASSE

13 Void After: July 2019 Product: Floor Drain Trap Seal Protection Devices File No Issued To: Green Drain Inc Models: Model No. Description GD-2 2" Drain GD-3 3" Drain GD " Drain GD-4 4" Drain Page 3 of 4

14 Void After: July 2019 Product: Floor Drain Trap Seal Protection Devices File No Issued To: Green Drain Inc ADDITIONAL COMPANY INFO: Liquid Breaker, LLC Model No. GD-102 GD-103 GD-1035 GD-104 Description 2" Drain 3" Drain 3.5" Drain 4" Drain Page 4 of 4

15

16

17 IAPMO R&T OCEANA 1040 Dandenong Road, Carnegie VIC 3163 AUSTRALIA IAPMO R&T Oceana is a product certification body which inspects and arranges for the independent laboratory testing of samples taken from the manufacturer s stock or from the market or a combination of both, to verify compliance of the requirements of applicable Standards and Specifications. This activity is c oupled with periodic surveillance of the manufacturer s factory and any major subcontractor s site/s as well as the assessment of the manufacturer s Quality Assurance System. This certification is subject to the conditions set forth i n the characteristics below and is not to be construed as any recommendation, assurance or guarantee by IAPMO R&T Oceana of the product acceptance by Authorities Having Jurisdiction. WATERMARK LICENCE WaterMark Level 2 IAPMO R&T Oceana hereby grants to: Green Drain Inc Collier Blvd Suit , Naples, FL, USA, the right to use the WaterMark in accordance with the Procedures for Certification of Plumbing and Drainage Products - WaterMark Technical Specification and the Plumbing Code of Australia only in respect of the certified product as described in the attached WaterMark Schedule. The Licence is granted subject to the rules governing the Watermark Certification Scheme and the Terms and Conditions for WaterMark Certification. Evaluated to: WMTS-522:2018 Barrier type floor drain trap seal protection devices Manufacturer: Refer to licence holder Licence No.: WM Certified Date: 30 July 2018 (Certificate of Certification No.: IAPMO-WM I01-R00) Issue Date: 30 July 2018 Expiry Date: 29 July 2021 Chief Executive Officer of the IAPMO Group This WaterMark certification is for the period indicated herein and is void after the date shown above. Any change in material, manufacturing process, marking or design without having first obtained the approval of IAPMO R&T Oceana, or any evidence of non-compliance with applicable Standards, Specifications or of inferior workmanship, may be deemed sufficient cause for revocation of this certification. Reproduction of or reference to this certificate for advertising purposes may be made only by specific written permission of IAPMO R&T Oceana. Any alteration of this certificate could be grounds for revocation of this certification.

18 CE marking The letters CE appear on many products traded on the extended Single Market in the European Economic Area (EEA). They signify that products sold in the EEA have been assessed to meet high safety, health, and environmental protection requirements. When you buy a new phone, a teddy bear, or a TV within the EEA, you can find the CE mark on them. CE marking also supports fair competition by holding all companies accountable to the same rules. By affixing the CE marking to a product, a manufacturer declares that the product meets all the legal requirements for CE marking and can be sold throughout the EEA. This also applies to products made in other countries that are sold in the EEA. There are two main benefits CE marking brings to businesses and consumers within the EEA: Businesses know that products bearing the CE marking can be traded in the EEA without restrictions. Consumers enjoy the same level of health, safety, and environmental protection throughout the entire EEA. CE marking is a part of the EU s harmonisation legislation, which is mainly managed by Directorate- General for Internal market, Industry, Entrepreneurship and SMEs. The CE marking for Restriction of Hazardous Substances is managed by Directorate-General for Environment. Comprehensive guidance on the implementation of EU product rules can be found in the so-called Blue Guide. This website provides information for manufacturers, importers and distributors on their responsibilities when placing a product on the EEA market. It also informs consumers about the rights and benefits that CE marking brings them. If you re looking for information on CE marking in your country, contact the Enterprise Europe Networkor check the list of contact points in the EEA.

19 2018 HOPE A/S Islandsvej 1 DK-7100 Vejle Tel EAD ETA-18/0536 DoP no. 1 Green Drain type: GD

20 2018 HOPE A/S Islandsvej 1 DK-7100 Vejle Tel EAD ETA-18/0536 DoP no. 1 Green Drain type: GD

21 May 6, 2016 Hohto Shoji Co., Ltd Green Drain Product Test Report Test House: Tokyo Metropolitan Industrial Technology Research Institute Testing Method and Results 1. Chemical Resistance Test Method: Soak Green Drains in four different detergents commonly used by Ikari for 24 hours at 23 degree Celsius (23±2 degree Celsius, humidity 50±5%) 1) Rich Foam NX (alkaline cleaner: dilution rate 5 times) 2) Rich Foam MF (sodium hypochlorite, alkaline cleaner: dilution rate 5 times) 3) Bleaker KT100 (fungicide, alkaline cleaner: dilution rate Undiluted) 4) Yudegama Cleaner (acidic cleaner: dilution rate 3 times) Test Result All test samples were rinsed with clean water and dried with paper towels then left for 24 hours for natural dry before inspection. Mass Change Ratio (weight): +0.21% Visual Inspection: No change in color nor shape. No sign of corrosion Tactile Impression: No change Harness Measurement (silicon skirt): No change

22 2. Thermal Shock Test Method: Keep Green Drains in thermostat chambers at temperature peak -10 degree Celsius to 100 degree Celsius (process repeated for five times: MIL-STD-202G) Test Result Visual Inspection: No change in color nor shape. No sign of corrosion Tactile Impression: No change Harness Measurement (silicon skirt): No change

23

24

25

26 Report Number: Report Issued: June 24, 2015 Project No.: Client: Green Drain, Inc. 335 North Puente Street # F Brea, CA Contact: Ben Wilson Source of Samples: The samples were shipped to IAPMO R&T Lab from Green Drain, Inc., and received in good condition on April 02, 2015, and May 18, Date of Testing: May 18, 2015 to June 23, Sample Description: Scope of Testing: Conclusion: Trap Seal Devices Models: *GD-102 (2 ) * = tested samples. GD-103 (3 ) GD (3.5 ) *GD-104 (4 ) The purpose of the testing was to determine whether the samples of the Trap Seal Devices met the applicable requirements of ASSE Standard # , Barrier Type Floor Drain Trap Seal Protection Devices. The samples tested of the Trap Seal Devices from Green Drain, Inc., models as shown above, complied with the applicable requirements of ASSE By our signatures below, we certify that all the testing and sample preparation for this report was performed under continuous, direct supervision of IAPMO R&T Lab, unless otherwise stated. Tested By, Reviewed by, Frank Lopez, Test Technician Sean Vuu, P.E., Specialty Projects Manager All testing and sample preparation for this report was performed under the continuous, direct supervision of IAPMO R&T Lab, unless otherwise stated. The observations, test results and conclusions in this report apply only to the specific samples tested and are not indicative of the quality or performance of similar or identical products. Only the Client shown above is authorized to copy or distribute the report, and then only in its entirety. Any use of the IAPMO R&T Lab name for the sale or advertisement of the tested material, product or service must first be approved in writing by IAPMO R&T Lab. Page 1 of 5

27 Primary Standards: ASSE Standard # / Section tested: 1. General 2. Test Specimens 3. Performance Requirements and Compliance Testing 4. Detailed Requirements Test Results: All tests and evaluations were conducted per the written procedures specified in the ASSE Standard # ASSE Standard # : 1.2 Scope: Description FOLLOWED The devices consisted of a membrane that allowed the flow of drainage to enter the plumbing drainage system. The devices closed when there was no flow Size COMPLIED The devices were sized according to the outlet sizes of the floor drains (2, 3, 3.5 and 4 ) Flow Capacity COMPLIED The devices permitted the flows of drainage as stipulated in Table 1 of this standard (refer to section 3.1) Rating FOLLOWED The devices were rated for the type of floor or floor finish in which the floor drain can be installed AF-GW. 1.3 Construction COMPLIED Function: the devices opened when there is a maximum of 4 oz of water on the inlet to the device, and closed when there was no flow of wastewater into the devices (refer to section 3.4) Evaporation: the devices passed the evaporation test described in Section 3.2 of this standard Obstruction of Flow: to prevent the collection of waste solids, the opening passageways in the device did not have any sharp edges or protrusions which would obstruct the flow to the drainage system or result in stoppages. The devices did not obstruct access to the interior of the floor drain trap Connections Within Floor Drain: the device connected within a floor drain that conformed to ANSI/ASME A Test Specimens: Report No.: Page 2 of 5

28 2.1 Sample Submitted FOLLOWED 6 devices of each size and model were submitted by the manufacturer. 2.2 Samples Tested FOLLOWED 1 sample was selected to be tested in order to sections 3.1 through 3.7 and additional 1 sample was selected to be tested to section 3.2, and another 1 sample was selected to be tested to section 3.8 of this standard. 2.3 Drawings FOLLOWED Assembly drawings, installation drawings, and other data which were necessary to enable the testing agency to determine compliance with this standard were accompanied assemblies when submitted for examination and performance testing under this standard. 2.4 Rejections FOLLOWED Failure of 1 device being tested shall be cause for rejection of that type or model and size. 3.0 Performance Requirements and Compliance Testing 3.1 Flow Test COMPLIED When tested to section of this standard, the trap seals were able to flow at 12 gpm (2 ) and 73 gpm (4 ) for 10 minutes without overflowing the open sides of the pans. 3.2 Evaporation Test COMPLIED When tested to section of this standard for 96 hours at 100ºF, 20% relative humidity, the weight loss in cylinder A: 70.41g (2 ), 269.9g (4 ), cylinder B: 2.64g (2 ; 3.75% of cylinder A), 7.8g (4 ; 2.89% of cylinder A), cylinder C: 1.47 g (2 ), 3.3g (4 ). 3.3 Trap Seal Interference Test COMPLIED When tested to section of this standard, there was no protrusion of the device into the floor drain trap seal. 3.4 Opening Test COMPLIED When tested to section of this standard, the devices started to open at: 1.31g (2 ), and 2.2g (4 ). 3.5 Dirt and Debris Test COMPLIED When tested to section of this standard, and subjected to section 3.2 for 96 hours, the weight loss in cylinder A: 75.42g (2 ), 253.3g (4 ), cylinder B: 2.53g (2 ; 3.35% of cylinder A), 8.4g (4 ; 3.32% of cylinder A), cylinder C: 1.44g (2 ), 3.0g (4 ). 3.6 Floor Wax Test COMPLIED Report No.: Page 3 of 5

29 When tested to section of this standard at 1 GPM, the devices did not overflow the floor drain top grates. 3.7 Grease Test COMPLIED When tested to section of this standard at 1 GPM, the devices did not overflow the floor drain top grates. 3.8 Life Cycle Test COMPLIED After tested to section of this standard, and subjected to section 3.2 for 96 hours, the weight loss in cylinder A: 77.59g (2 ), 290g (4 ), cylinder B: 3.2g (2 ; 4.12% of cylinder A), 9.7g (4 ; 3.34% of cylinder A), cylinder C: 1.73 g (2 ), 4.2g (4 ). 3.9 Physical Test of Membrane Material COMPLIED (refer to CRT report no.: S1). 4.1 Materials - COMPLIED Dissimilar Metals NOT APPLICABLE (no metal) Internal Metallic Parts NOT APPLICABLE (no metal) Non-metallic Parts - COMPLIED Nonmetallic part (rubber & plastic) was designed for the rated operating temperature of the device without change in physical characteristics that would prevent full compliance with all requirements of this standard Marking of Devices COMPLIED Each device had the following information marked (molded), which is visible: a) Trademark GREEN DRAIN (per drawings). b) Application designation AF-GW Packaging - COMPLIED Each device had the following information marked (printed) on the packaging: a) Manufacturer s name The Green Drain b) Model number c) Rating for type of floor AF-GW d) Floor drain size. 4.3 Installation Instruction - COMPLIED Instruction for installation of the device press to install in drain outlet was printed on the package. Report No.: Page 4 of 5