Lovibond Water Testing. Tintometer Group. Pool & Spa Water Analysis. Instruments and Reagents.

Size: px
Start display at page:

Download "Lovibond Water Testing. Tintometer Group. Pool & Spa Water Analysis. Instruments and Reagents."

Transcription

1 Lovibond Water Testing Tintometer Group Pool & Spa Water Analysis Instruments and Reagents

2 Lovibond -Handbook Pool & Spa Water Treatment and Analysis The handbook includes detailed information on topics relating to swimming pools and spas with reference to the standard methods used for water treatment and testing. National and international standards and regulations are also covered. Handbook order code: Visit the support area on our website at to obtain a copy of the handbook. Pool & Spa Water Testing - January 2015

3 Content Pools & Spas Natural Swimming Ponds Introduction public Relations from page 4 Basic information Hygiene parameters from page 56 Rapid Tests Photometry Electro Analytical Meters NeW pooltester from page 8 MD 100 from page 38 SD Series from page 58 MINIKIT MINIKIT from page 12 MD 200 from page 42 SensoDirect Series 110 & 150 from page 60 SCUBA II Turbidity Meter electronic pooltester from page 14 NeW pm 600 & pm 620 (Infrared) pm 630 (Bluetooth) from page 46 TB 210 IR from page 64 CHECKIT Comparator Reagents Poolsoftware Colorimeter from page 16 Tablet Reagents from page 48 poolsoftware from page 66 Comparator System Index from page 70 Colorimetric System from page 24 Liquid Reagents from page 48 Pool & Spa Water Testing - January 2015

4 Pools & Spas Swimming and bathing are without doubt some of the most popular leisure activities, whether at school, in a competitive environment, for exercise or simply relaxation. The concept of "Wellness has created a new trend; wellness enthusiasts are people who have made a conscious decision to stay fit and active with the aim of achieving/maintaining good health and a general feeling of well-being and attaining harmony of body, mind and soul. In order to achieve this goal, people make wide-ranging use of swimming pools, spas, and many other similar facilities. Regardless of the motivation for swimming and similar activities, people attach great importance to clean and hygienic water both indoors and out. Water Treatment and Water Testing State-of-the-art water treatment is an essential precondition for safe and healthy bathing and swimming whether in private or public facilities. In order to satisfy health-related criteria while maintaining the value of such a facility, the golden rule for water treatment is "as much as necessary and as little as possible. It goes without saying that the main water quality parameters need to be checked on a regular basis in order to ensure an optimum water treatment programme in changing operating conditions. If testing shows that the hygiene-related parameters deviate from the target values or recommended limit values, the operator can immediately take corrective action to avoid potential risks to health before such risks are allowed to arise. And this is where the system of Lovibond water testing equipment and reagents comes into play. The Lovibond range of instruments provides operators of private and public baths with analysis systems that measure the actual condition and quality of the water with maximum precision. Moreover, the Lovibond systems succeed in reconciling the seemingly irreconcilable goals of easy handling, safe reagents offering long-term stability, high detection accuracy, and reproducibility of results. We hope you will find the information on the following pages convincing. 4 Pool & Spa Water Testing - January 2015

5 Public Relations Bundesverband Schwimmbad & Wellness e.v. An Lyskirchen Cologne Germany Bundesverband Deutscher Schwimmmeister e. V. Römerstr Wesseling Germany TÜV Rheinland Akademie GmbH TÜV Rheinland Group Rhinstr Berlin Germany Lehr- und Versuchsgesellschaft für innovative Hygienetechnik GmbH Bleichstraße Mülheim Germany Verein zur Förderung des IWW Rheinisch-Westfälisches Institut für Wasserforschung e. V. Moritzstraße Mülheim an der Ruhr Germany Bundesverband der Hygieneinspektoren e. V. Hohenstaufenstr Berlin Germany SCHWIMMBAD- UND SAUNAWIRTSCHAFT Österreichischer Verband der Schwimmbad- und Saunawirtschaft Wiedner Hauptstraße Vienna Austria Schweizerische Vereinigung von Firmen für Wasser- und Schwimmbadtechnik Schlösslistraße 9 A 3001 Bern Switzerland Verband zur Fortbildung im Bereich des Gesundheits- und Infektionsschutzes e.v. Geschäftsstelle Wolfsburg Grashof Wolfsburg Germany 5 Pool & Spa Water Testing - January 2015

6 Rapid Tests Pooltester 6 Three Chamber Tester Minikit Pool & Spa Water Testing - January 2015

7 Get the clip! CHECKIT Comparator Comparator Scuba II 7 Pool & Spa Water Testing - January 2015

8 Rapid Tests NeW Active Oxygen Biguanide (PHMB) Bromine Calcium Hardness Chloride Chlorine Copper Cyanuric acid Hydrogen Peroxide ph-value QAC Sulphate Total Alkalinity Total Hardness 8 Pool & Spa Water Testing - January 2015

9 Water Treatment Rapid Tests ph value The ph value of pool & spa water should generally be between the slightly acidic value of 6.5 and the slightly basic value of 7.6. Due to the use of various water treatment chemicals as well as ambient environmental effects, pool owners have to determine the ph of the water and correct the value as necessary. Disinfection Nowadays, pool owners can choose from a range of modern water treatment agents that are often used in combination. These water treatment chemicals are only effective within a limited ph range. Therefore in addition to checking the concentration of the water treatment chemicals, the owner/ operator should also monitor the ph value of pool water and adjust it if necessary. Minitester The Minitester with an interchangeable colour comparison chart is a competitively priced starter unit with one measuring chamber for the determination of either chlorine, bromine, active oxygen and the ph value. Three-Chamber Tester The Three-Chamber Tester with an interchangeable colour comparison chart is a competitively priced unit for the determination of disinfectants and the ph value. Pooltester The Pooltester allows simultaneous determination of the most popular water treatment agents and the ph value. Highlights Easy to use Futuristic design RAPID tablets fast dissolving Highest accuracy Rapid Tests 9 Pool & Spa Water Testing - January 2015

10 Minitester Item Code Chlorine- ph 1) Chlorine mg/l / ph value Bromine-pH 1) Bromine 1 8 mg/l / ph value Active Oxygen-pH 1) Active Oxygen 0 10 mg/l / ph value ) in bubble pack ; 2) in plastic case Three-Chamber-Tester Item Code Chlorine- ph LR 1) Chlorine mg/l / ph value Chlorine-pH HR 1) Chlorine mg/l / ph value Bromine-pH 1) Bromine mg/l / ph value Active Oxygen-pH 1) Active Oxygen 0 10 mg/l / ph value Biguanide (phmb)-ph 1) Biguanide (PHMB) mg/l ph value in 1 2) Chlorine LR mg/l / ph value Cyanuric acid mg/l / Alkalinity-M mg/l 4 in 1 2) Chlorine HR mg/l / ph value Cyanuric acid mg/l / Alkalinity-M mg/l 5 in 1 2) Chlorine LR mg/l / ph value Cyanuric acid mg/l / Alkalinity-M mg/l Calcium hardness mg/l 5 in 1 2) Chlorine HR mg/l / ph value Cyanuric acid mg/l / Alkalinity-M mg/l Calcium hardness mg/l 6 in 1 2) Chlorine LR mg/l / ph value Cyanuric acid mg/l / Alkalinity-M mg/l Calcium hardness mg/l / Acid demand 6 in 1 2) Chlorine HR mg/l / ph value Cyanuric acid mg/l / Alkalinity-M mg/l Calcium hardness mg/l / Acid demand Pooltester Item Code Chlorine- ph LR Chlorine mg/l / ph value Chlorine-pH HR Chlorine mg/l / ph value Bromine-pH Bromine mg/l / ph value Active Oxygen-pH O mg/l / ph value Copper LR/HR-pH Copper LR mg/l & HR mg/l ph value Active Oxygen-Copper-pH O mg/l / Copper mg/l ph value Biguanide (phmb) Hydrogen peroxide (H 2 O 2 )-ph PHMB mg/l / H 2 O mg/l ph value Quaternary Ammonia Compounds ( QAC)-pH QAC mg/l / ph value Delivery content Minitester in a bubble pack Tablet reagents for 20 tests Instruction manual Pack contains 6 units Delivery content Three-Chamber-Tester in a bubble pack Tablet reagents for 20 tests Instruction manual Pack contains 6 units Delivery content Pooltester in a sturdy plastic box Tablet reagents for 20 tests Instruction manual Pack contains 6 units 10 Pool & Spa Water Testing - January 2015

11 Refill Packs Item Code Chlorine / ph* DPD No. 1 / RAPID-tablets and 30 PHENOL RED / RAPID-tablets Bromine / ph* DPD No. 1 / RAPID-tablets and 30 PHENOL RED / RAPID-tablets Active Oxygen - ph* DPD No. 4 / RAPID-tablets and 30 PHENOL RED / RAPID-tablets Active Oxygen - Copper - ph* DPD No. 4 / RAPID-tablets 20 COPPER No.1-tablets and 20 PHENOL RED / RAPID-tablets phmb/h 2 O 2 - ph PHMB-, 20 H 2 O 2 -, 20 ACIDIFYING PT- and 20 PHENOL RED / RAPID-tablets phmb - ph* PHMB-tablets and 30 PHENOL RED / RAPID-tablets QAC HR - ph* QAC-, 20 ACIDIFYING GP- and 20 PHENOL RED / RAPID-tablets Copper - ph* COPPER No.1-tablets and 30 PHENOL RED / RAPID-tablets Reagents Item Quantity Code Acid Demand 10 ml Acidifying Gp 100 pc BT 250 pc BT Acidifying pt 100 pc pc ALK LR 100 pc CALC 100 pc Copper No pc BT 250 pc BT Cyanuric Acid CyA-TeST 100 pc BT 250 pc BT DpD No.1 / RApID 100 pc BT 250 pc BT 500 pc BT Highlights Item Quantity Code DpD No.3 / RApID 100 pc BT 250 pc BT 500 pc BT DpD No.4 / RApID 100 pc BT 250 pc BT 500 pc BT Hydrogenperoxide HR 100 pc BT 250 pc BT phenol ReD/RApID 100 pc BT 250 pc BT 500 pc BT phmb 100 pc pc QAC HR 100 pc pc also suitable for seawater Rapid Tests Combi pack for Three-Chamber-Tester 4 in 1 20 DPD No. 1/ RAPID-, 20 PHENOL RED / RAPID-, 20 ALK LR- 20 CyA-TEST-tablets Lovibond -RAPID tablets DPD and PHENOL RED will dissolve quickly, have a guaranteed 10 year shelf-life and are provided in green-printed foil blister. Material Safety Data Sheets: Combi pack for Three-Chamber-Tester 5 in 1 20 DPD No. 1/ RAPID-, 20 PHENOL RED / RAPID-, 20 ALK LR- 20 CyA-TEST 20 CALC-tablets * Each pack contains 12 units 11 Pool & Spa Water Testing - January 2015

12 MINIKIT Photo: Elsebad, Schwerte, Methods Tablet Speed Yes/No Turbidity Analysis Type Range Count Test Test Code Alkalinity, Total-M AF mg/l CaCO 3 = ~ mmol/l Alkalinity, Total-M AF mg/l CaCO 3 = ~ mmol/l Alkalinity-P AF mg/l CaCO 3 = ~ mmol/l Calcium Hardness AF mg/l CaCO 3 = ~ mmol/l Calcium Hardness AF mg/l CaCO 3 = ~ mmol/l Chloride AF mg/l Cl Cyanuric Acid AF mg/l Cyanuric Acid QAC (Quaternary AF mg/l active QAC Ammonium Comp.) Limit 200 mg/l (Yes/No) Sulphate AF mg/l SO 4 ( mg/l by dilution) Total Hardness AF mg/l CaCO 3 = ~ mmol/l Total Hardness AF mg/l CaCO 3 = ~ mmol/l also suitable for seawater 12 Pool & Spa Water Testing - January 2015

13 The Methods The Minikits are developed for fast testing, mainly based on titrimetric methods Rapid Tests Photo: Elsebad, Schwerte, Tablet count method A specific number of tablets is added to a known volume of sample until a chemically induced colour change takes place. The number of tablets used is applied to a simple formula to calculate the test result. The measuring range may be expanded by varying the sample volume. Speed test The speed test is based on reverse titration. After adding a reagent tablet to a calibrated test tube, the water sample is added slowly until the colour of the solution changes (e.g. from red to blue). The user can then obtain the result from the liquid level. Yes/No test A Yes/No test tells the user whether a specific ingredient is present in the water and/or if its concentration is higher or lower than a defined level. Turbidity method A two-section calibrated test tube is filled with the water sample and a reagent tablet added. The reagent creates a level of turbidity that is proportional to the concentration of the parameter being measured. The inner tube, which has a black dot on its base, is lowered until the dot is obscured by the turbidity. The result is read off from the water level in the inner tube. Highlights Easy operation Exact reagent dosing Measurement accuracy Tablet reagents with a guaranteed shelf life of 5 years Tablet Reagents Code Quantity ALKALINITY-M BT 250 BaCl 2 -Tablets BT 100 ALK-TEST BT 100 ALKALINITY-P CAL-TEST CALCIUM HARDNESS CHLORIDE CyA-TEST BT 100 QAC-Test SULFATE BT 250 TOTAL HARDNESS BT 250 T HARDNESS-TEST Delivery content Kit in a plastic box Tablet reagents for an average of 30 tests Sample container Required accessories Instruction manual MSDS (Material Safety Data Sheets): 13 Pool & Spa Water Testing - January 2015

14 Scuba II Electronic Pooltester Chlorine, free & total ph Cyanuric acid Alkalinity Test equipment for the responsible private swimming pool and whirlpool operator 14 Pool & Spa Water Testing - January 2015

15 Scuba II Every pool owner should check the most important parameters in his pool at regular intervals. This is the only way to ensure that water quality is maintained at an right level and to arrange dosing in an optimum manner. Technical Data Optics power supply temperature-compensated LED (λ = 530 nm) and photo-sensor 2 batteries (AAA), capacity minimum 500 tests Highlights Modern, ergonomic design User friendly handling The Scuba II enables the operator to check the pool water quickly and accurately. The integrated sample chamber filled by immersing it in the water. A tablet reagent is added and generates a characteristic colour which can be measured using the photometric principle. The result is then displayed on the screen. Five parameters, free chlorine, total chlorine, ph, alkalinity and cyanuric acid are measured within a few minutes. Water analysis becomes a pleasure rather than a chore and more time is left for enjoying the pleasure of the pool. If the Scuba II falls into the water it will simply float and, of course, it is watertight. Why not try this compact test equipment after all, the knowledge that you are safe in a thoroughly hygienic pool is worth a little effort. Auto-Off Display Dimensions (L x W x H) Weight automatic switch-off approx. 5 minutes after last key press LCD 145 x 70 x 45 mm approx. 165 g (incl. batteries) Operating temperature: 5 40 C conditions relative humidity: 30 90%, non-condensing Approval CE Watertight housing * Large display * as defined in IP 68, 1 hour at 0.1 meter Scuba Refill pack Article Code Refill pack for Scuba II DPD No. 1 Photometer tablets 10 DPD No.3 Photometer tablets 10 PHENOL RED Photometer tablets 10 CyA-Test tablets 10 Alka-M-Photometer tabletsn packaging unit = 12 packs Get the clip! Delivery content Scuba II in a robust plastic box Tablet reagents each 20 DPD No.1 & Phenol Red Photometer each 10 DPD No.3, CyA-Test & Alka-M-Photometer 2 batteries (AAA) Stirring rod Instruction manual Order code: Determination Range Resolution Accuracy Chlorine, free mg/l Cl mg/l 0-1 mg/l ± 0.1 mg/l ; 1-2 mg/l ± 0.2 mg/l 2-3 mg/l ± 0.4 mg/l ; 3-6 mg/l ± 0.5 mg/l Chlorine, total mg/l Cl mg/l 0-1 mg/l ± 0.1 mg/l ; 1-2 mg/l ± 0.2 mg/l 2-3 mg/l ± 0.4 mg/l ; 3-6 mg/l ± 0.5 mg/l ph Value ph 0.1 ph ± 0.2 ph Cyanuric acid mg/l 1.0 mg/l 1-50 mg/l ± 10 mg/l ; mg/l ± 20 mg/l Alkalinity (total) mg/l CaCO mg/l ± 50 mg/l 15 Pool & Spa Water Testing - January 2015

16 CHECKIT Comparator with continuous colour scales 16 Pool & Spa Water Testing - January 2015

17 Front view of the CHECKIT Comparator with cells Test Kit in carrying case, ready to use Plastic cells, frosted on two sides, volume 10 ml, path length 13.5 mm, with lids CHeCKIT Comparator Tablet reagents in foil blister strips CHECKIT Discs with continuous and stable scales Rear view of the CHECKIT Comparator with diffuser plate, cells and disc CHECKIT Comparator The Lovibond CHECKIT Comparator is a compact, handy colorimetric unit which is suitable for both mobile and static analysis work. Supplied with a generous number of different colour scales, it provides the basis for a comprehensive, easy-touse colorimetric analysis system. CHECKIT Disc Each CHECKIT Disc contains a continuous colour scale which makes it possible to achieve an exact colour match between the colour standard and the sample. These CHECKIT Discs are specially manufactured in selected materials to retain colour-stability over a long period and guarantee reliable, reproducible measurement results. Please see pages 20 onwards for tests, ranges and reagents Highlights Easy operation Exact reagent dosing Tablet reagents with a guaranteed shelf life of 5/10 years Measurement accuracy Continuous colour scales 17 Pool & Spa Water Testing - January 2015

18 CHECKIT Comparator Photo: Riviera Pool, Colorimeter for regular testing in Pools and Spas 18 Pool & Spa Water Testing - January 2015

19 Test Kits 2 in 1 Test Kit Code Chlorine mg/l Cl 2 * ph value ph Chlorine mg/l Cl 2 * ph value ph Chlorine mg/l Cl 2 * ph value ph Bromine mg/l Br ph value ph Copper mg/l Cu ph value ph Delivery content CHECKIT Comparator in a sturdy plastic case CHECKIT Disc(s) 3 cells & 1 stirring rod Tablet reagents for 30 tests each Warranty information Instruction manual Test Kit 5 in 1 Water Balance Code Chlorine mg/l Cl 2 * ph value ph Cyanuric acid (turbidity method)* mg/l Cys Calcium hardness (Speed-Test)* mg/l CaCO 3 Total Alkalinity (Speed-Test)* mg/ CaCO 3 Disc readings see following pages * All test kits for chlorine are for free, combined and total chlorine ** Reagents for turbidity method and speed-test (Test-Kit 5 in 1) see Minikit, page 11 Single Parameter Test Kits Test Kit Range* Reagent Code (±5% Full Scale) Aluminium mg/l Al Tablets Ammonia 0-1 mg/l N Tablets Bromine 0-5 mg/l Br Tablets Chlorine (DPD), free, comb., total 0-1 mg/l Cl 2 Tablets Chlorine (DPD), free, comb., total 0-2 mg/l Cl 2 Tablets Chlorine (DPD), free, comb., total 0-4 mg/l Cl 2 Tablets Chlorine (DPD) free+total mg/l Cl 2 Powder Reagents Copper, free 0-1 mg/l Cu Tablets Copper, free + total 0-5 mg/l Cu Tablets Iron 1-10 mg/l Fe Tablets Iron mg/l Fe Tablets Ozone (DPD) mg/l O 3 Tablets Ozone (in presence of chlorine) mg/l O 3 Tablets ph value (Phenol red) ph Tablets ph value (Bromocresol purple) ph Tablets ph value (Universal) 4-10 ph Tablets phosphate 0-4 mg/l PO 4 Tablets phosphate 0-80 mg/l PO 4 Tablets Sodiumhypochlorite 2-18 % NaOCl Tablets Total Alkalinity mg/l CaCO 3 Tablets * Disc readings see following pages also suitable for seawater Testpak The Testpak is a simple and cost-effective means of extending the use of an existing CHECKIT Comparator instrument to a new test parameter. All you need is the basic CHECKIT Comparator, order code Testpaks: see following pages. CHeCKIT Comparator Please see pages 20 onwards for tests, ranges and reagents Delivery content CHECKIT Disc Plastic cells in pack, available: 5 cells cells cells cells & 1 stirring rod Tablet reagents for 30 tests Instruction manual 19 Pool & Spa Water Testing - January 2015

20 CHECKIT Comparator Tests, Test Kits, Testpaks, Discs, Reagents Test Range Readings (Accuracy ± 5% Fullscale) Test Kit Testpak Aluminium mg/l Al 0 / 0.01 / 0.02 / 0.03 / 0.04 / 0.05 / 0.06 / 0.07 / Tablets 0.08 / 0.09 / 0.1 / 0.15 / 0.2 / 0.25 / 0.3 Ammonia 0-1 mg/l N 0 / 0.05 / 0.1 / 0.15 / 0.2 / 0.25 / 0.3 / 0.35 / 0.4 / 0.45 / Tablets 0.5 / 0.55 / 0.6 / 0.65 / 0.7 / 0.75 / 0.8 / 0.9 / 0.95 / 1.0 Bromine 0-5 mg/l Br 0 / 0.2 / 0.4 / 0.6 / 0.8 / 1.0 / 1.2 / 1.4 / 1.6 / 1.8 / 2 / Tablets 2.5 / 3 / 3.5 / 4 / 4.5 / 5 Chlorine 0-1 mg/l Cl 2 0 / 0.05 / 0.1 / 0.15 / 0.2 / 0.25 / 0.3 / 0.35 / 0.4 / free, combined, total 0.45 / 0.5 / 0.55 / 0.6 / 0.65 / 0.7 / 0.75 / 0.8 / 0.85 / Tablets 0.9 / 0.95 / 1.0 Chlorine 0-2 mg/l Cl 2 0 / 0.1 / 0.2 / 0.3 / 0.4 / 0.5 / 0.6 / 0.7 / 0.8 / 0.9 / 1.0 / free, combined, total 1.1 / 1.2 / 1.3 / 1.4 / 1.6 / 1.8 / 2.0 Tablets Chlorine 0-4 mg/l Cl 2 0 / 0.2 / 0.4 / 0.6 / 0.8 / 1.0 / 1.2 / 1.4 / 1.6 / 1.8 / free, combined, total 2.0 / 2.5 / 3.0 / 3.5 / 4.0 Tablets Chlorine mg/l Cl 2 0 / 0.2 / 0.4 / 0.6 / 0.8 / 1 / 1.2 / 1.4 / 1.6 / 1.8 / 2 / , frei free, combined, total 2.2 / 2.4 / 2.6 / 2.8 / 3 / 3.2 / 3.4 / , gesamt Powder Reagent Copper, free (Cu 2+ ) 0-1 mg/l Cu 0 / 0.1 / 0.2 / 0.3 / 0.4 / 0.5 / 0.6 / 0.7 / 0.8 / 0.9 / Tablets Copper HR 0-5 mg/l Cu 0 / 0.5 / 1.0 / 1.5 / 2.0 / 2.5 / 3.0 / 3.5 / 4.0 / 4.5 / free and total Tablets * RAPID: fast dissolving tablets, # including stirring rod, also suitable for seawater 20 Pool & Spa Water Testing - January 2015

21 Disc Reagents Quantity Code ALUMINIUM No BT BT ALUMINIUM No BT BT Combi pack # each BT ALUMINIUM No.1 / No.2 each BT AMMONIA No BT BT AMMONIA No BT BT Combi pack # each BT AMMONIA No.1 / No.2 each BT DPD No.1-RAPID* BT BT BT CHECKIT Comparator DPD No.1-RAPID* BT BT BT DPD No.3-RAPID* BT BT BT DPD No.4-RAPID* BT BT BT DPD No.1/3/4-RAPID* DPD No.1/3/4-RAPID* VARIO Chlorine Free DPD F VARIO Chlorine Total DPD F COPPER/ZINC LR BT BT COPPER No BT BT COPPER No BT BT Combi pack # each BT COPPER No.1 / No.2 each BT Material Safety Data Sheets: 21 Pool & Spa Water Testing - January 2015

22 CHECKIT Comparator Tests, Test Kits, Testpaks, Discs, Reagents Test Range Readings (Accuracy ± 5% Fullscale) Test Kit Testpak Iron LR 0-1 mg/l Fe 0.05 / 0.1 / 0.15 / 0.2 / 0.25 / 0.3 / 0.35 / 0.4 / 0.45 / Tablets 0.5 / 0.55 / 0.6 / 0.65 / 0.7 / 0.75 / 0.8 / 0.9 / 1.0 Iron HR 1-10 mg/l Fe 1 / 1.5 / 2 / 2.5 / 3 / 3.5 / 4 / 4.5 / 5 / 5.5 / 6 / 6.5 / Tablets 7 / 7.5 / 8 / 8.5 / 9 / 10 Ozone (DPD) mg/l O 3 0 / 0.05 / 0.1 / 0.15 / 0.2 / 0.25 / 0.3 / 0.35 / 0.4 / Tablets 0.45 / 0.5 / 0.55 / 0.6 / 0.65 / 0.7 / 0.75 / 0.8 / 0.9 / 1.0 Ozone (DPD) mg/l O 3 0 / 0.05 / 0.1 / 0.15 / 0.2 / 0.25 / 0.3 / 0.35 / 0.4 / in the presence 0.45 / 0.5 / 0.55 / 0.6 / 0.65 / 0.7 / 0.75 / 0.8 / 0.9 / 1.0 of chlorine ph ph 5.2 / 5.3 / 5.4 / 5.5 / 5.6 / 5.7 / 5.8 / 5.9 / 6.0 / 6.1 / Tablets 6.2 / 6.3 / 6.4 / 6.5 / 6.6 / 6.7 / 6.8 ph 4-10 ph 4 / 4.5 / 5 / 5.5 / 6 / 6.5 / 7 / 7.5 / 8 / 8.5 / 9 / 9.5 / Tablets Phosphate HR 0-80 mg/l PO 4 0 / 5 / 10 / 15 / 20 / 25 / 30 / 35 / 40 / 45 / 50 / 55 / Tablets 60 / 65 / 70 / 75 / 80 Phosphate LR 0-4 mg/l PO 4 0 / 0.25 / 0.5 / 0.75 / 1.0 / 1.25 / 1.5 / 1.75 / 2.0 / 2.25 / Tablets 2.5 / 2.75 / 3.0 / 3.25 / 3.5 / 3.75 / 4.0 Sodiumhypochlorite 2-18 % 2 / 3 / 4 / 5 / 6 / 7 / 8 / 9 / 10 / 11 / 12 / 13 / 14 / 15 / 16 / Tablets Total Alkalinity mg/l CaCO 3 20 /30 / 40 / 50 / 60 / 70 / 80 / 90 / 100 / 110 / 120 / Tablets 140 / 150 / 160 / 170 / 180 / 190 / 200 / 220 / 240 * RAPID: fast dissolving tablets, # including stirring rod, also suitable for seawater 22 Pool & Spa Water Testing - January 2015

23 Disc Reagents Quantity Code IRON LR (Fe 2+ and Fe 3+ ) BT BT IRON (II) LR (Fe 2+ ) BT IRON HR BT BT DPD No BT BT DPD No BT BT DPD Glycine BT BT CHECKIT Comparator BROMOCRESOL PURPLE UNIVERSAL PH PHOSPHATE HR BT PHOSPHATE No. 1 LR BT PHOSPHATE No. 2 LR BT Combi pack # each BT PHOSPHATE No.1 LR / No.2 LR CHLORINE HR (KI) BT BT ACIDIFYING GP BT BT Combi pack # each BT CHLORINE HR (Ki)/ACIDIFYING GP each BT Dilution set for sample preparation ALKACHECK BT BT Material Safety Data Sheets: 23 Pool & Spa Water Testing - January 2015

24 Comparator Colorimeter for regular testing in public pools & spas with colour-stable glass standards 24 Pool & Spa Water Testing - January 2015

25 Comparator With its accessories, the Lovibond Comparator system 2000 is an extremely versatile, modular system for testing water. It is simple to use yet is uncompromising in terms of precision and reproducibility of results. It is compact and portable. The integrated prism brings the glass standards of the test discs and the coloured sample into the same field of view. Discs The required accuracy of results is only ensured if stable, fade-free colour standards are used. Glass colour standards are fade-free, resistant to chemicals and scratchproof. Lovibond standards are made from coloured glass filters. They comply with international standards, e.g. ISO 7393/2. For a selection of the most popular test discs see the table on page 26 onwards. Cells We manufacture precision plastic and optical glass cells in line with the highest quality standards. The cells ensure high precision and reproducibility of results. Lightning unit We recommend the use of the battery-operated Lovibond lighting unit in variable lighting conditions. This guarantees uniform lighting conditions, and ensures greater test accuracy. Please see pages 28 onwards for tests, ranges and reagents Highlights Accurate and reproducible results Colour-stable, fade-free glass standards In accordance with ISO 7393/2 "Determination of free chlorine and total chlorine" Integrated prism Comparator System 2000 Lighting unit, battery operated Comparator Disc 25 Pool & Spa Water Testing - January 2015

26 Test Kits Photo: Riviera Pool, Type* Test Kits Code Type* Test Kits Code AF 112 A Chlorine mg/l, Type 3/40 A** AF 112 B Chlorine mg/l, Type 3/40 B** AF 112 J/J Chlorine mg/l, Type 3/40 J** ph value , Type 2/1 J AF 116 A Chlorine mg/l, Type 3/40 A** ph value , Type 2/1 J AF 116 B Chlorine mg/l, Type 3/40 B** ph value , Type 2/1 J * Disc readings see following pages AF 118 S Chlorine mg/l, Type 3/40 A** Chlorine mg/l, Type 3/40 S** ph value , Type 2/1 G ph value , Type 2/1 J AF 129 Water Balance Chlorine mg/l, Type 3/40 B** ph value , Type 2/1 J Total Alkalinity-M*** mg/l CaCO 3 Tablet Count Method Calcium Hardness*** mg/l CaCO 3 Tablet Count Method ** All test kits for chlorine are for free. combined and total chlorine Type* Test Kits Code AF 405 M Municipal Kit Chlorine mg/l, Type 3/40 B** ph value , Type 2/1 J Cyanuric Acid*** mg/l Cyanuric Acid Turbidity Method Total Alkalinity-M*** mg/l CaCO 3 Speed-Test Calcium Hardness*** mg/l CaCO 3 Speed-Test *** Reagents for tablet count method, turbidity method and speed-test see Minikit, page Pool & Spa Water Testing - January 2015

27 Comparator and Accessories Type Item Code TK 100 Lovibond Comparator TK 102 Portable lighting unit, battery operated Daylight Unit, mains operated AF 631 Water sampler with two 500 ml bottles and one lid (p. 29) Measuring beaker, 100 ml Vial stand for 10 vials (ø 16 mm or 13,5 mm), acrylic glass Glass stirring rod, 12 cm length Plastic stirring rod, 13 cm length Brush, 11 cm length Delivery content Comparator in a sturdy plastic case Disc(s) Cells & accessories Tablet reagents for 100 tests Warranty information Instruction manual Glass Cells Type Item Code DB424/S 5 glass cells with lid, volume 10 ml, calibrated 2-12 ml, path length 13,5 mm W 680/40 Glass cell 40 mm path length, calibrated at 20 ml Plastic Cells 5 plastic cells, frosted on two sides, mm path length, volume 10 ml, with lid 10 plastic cells, as plastic cells, as Daylight unit, mains operated Comparartor Test Kit Plastic cells 27 Pool & Spa Water Testing - January 2015

28 Comparator Tests, Discs, Reagents, Cells Test Disc Disc Readings Range Code Aluminium 3/127 A 0; 0.05; 0.1; 0.15; 0.2; 0.25; 0.3; 0.4; 0.5 mg/l mg/l Ammonia 3/112 0; 0.05; 0.1; 0.15; 0.2; 0.25; 0.3; 0.35; 0.4 mg/l mg/l NH Ammonia 3/113 0; 0.1; 0.2; 0.3; 0.4; 0.5; 0.6; 0.8; 1 mg/l mg/l N Bromine 3/53A 0.2; 0.4 ; 0.6; 0.8; 1; 1.2; 1.4; 1.6; 2 mg/l mg/l Bromine 3/53B 1; 2; 3; 4; 5; 6; 7; 8; 10 mg/l mg/l Bromine 3/53C 0.5; 1; 1.5; 2; 2.5; 3; 4; 5; 6 mg/l mg/l Chlorine 3/40A 0.1; 0.2; 0.3; 0.4; 0.5; 0.6; 0.7; 0.8; 1 mg/l mg/l free, combined, total Chlorine 3/40J 0.1; 0.2; 0.3; 0.4; 0.6; 0.8; 1; 1.5; 2 mg/l mg/l free, combined, total Chlorine 3/40B 0.2; 0.4; 0.6; 1; 1.5; 2; 2.5; 3; 4 mg/l mg/l free, combined, total 28 also suitable for seawater, # including stirring rod * alternative reagent, used instead of DPD No.1 in case of turbidity in the water sample caused by high concentration of calcium and/or high conductivity Pool & Spa Water Testing - January 2015

29 Reagents Quantity Code Accessories Code ALUMINIUM No BT 13.5 mm cell, 10ml BT ALUMINIUM No BT BT Combi pack # each BT ALUMINIUM No.1 / No.2 each BT AMMONIA No BT 40 mm cell W680/ BT AMMONIA No BT BT Combi pack # each BT AMMONIA No.1 / No.2 each BT AMMONIA No.1/ mm cell, 10ml DPD No BT 13.5 mm cell, 10ml BT BT Comparator System 2000 DPD No mm cell, 10ml DPD No mm cell, 10ml DPD No BT 13.5 mm cell, 10ml BT BT DPD No.1 HIGH CALCIUM* BT DPD No BT BT BT DPD No BT BT BT DPD No.3 HIGH CALCIUM* BT Combi pack # each BT DPD No.1 / No.3 each BT Combi pack # each BT DPD No.1 / No.3 each BT HIGH CALCIUM* DPD No BT BT BT DPD No.1/2/3/ mm cell, 10ml DPD No.1/2/3/ mm cell, 10ml MSDS (Material Safety Data Sheets): 29 Pool & Spa Water Testing - January 2015

30 Comparator Tests, Discs, Reagents, Cells Test Disc Disc Readings Range Code Chlorine 3/40K 0.5; 1; 1.5; 2; 2.5; 3; 4; 5; 6 mg/l mg/l free, combined, total Chlorine 3/40S 1; 1.2; 1.4; 1.6; 1.8; 2; 2.5; 3; 4 mg/l mg/l free, combined, total Chlorine 3/40P 2; 2.3; 2.5; 2.7; 3; 3.2; 3.6; 4; 5 mg/l mg/l free, combined, total Chlorine 3/40HN 2; 3; 4; 5; 6; 7; 8; 9; 10 mg/l mg/l free, combined, total Copper 3/106 0; 0.1; 0.2; 0.3; 0.4; 0.5; 0.6; 0.8; 1 mg/l mg/l Copper 3/110 0; 0.5; 1; 1.5; 2; 2.5; 3; 3.5; 4 mg/l mg/l Hydrogen Peroxide 3/114 2; 4; 6; 8; 10; 12; 14; 16; 20 mg/l 2-20 mg/l Hydrogen Peroxide 3/115 10; 20; 30; 40; 50; 60; 70; 80; 100 mg/l mg/l Iron, 3/ ; 0.2; 0.3; 0.4; 0.5; 0.6; 0.7; 0.8; 1 mg/l mg/l total Iron, 3/117 1; 2; 3; 4; 5; 6; 7; 8; 10 mg/l mg/l total Manganese 3/169 0; 0.5; 1; 1.5; 2; 2.5; 3; 3.5; 4 mg/l mg/l also suitable for seawater, # including stirring rod * alternative reagent, used instead of DPD No.1 in case of turbidity in the water sample caused by high concentration of calcium and/or high conductivity Pool & Spa Water Testing - January 2015

31 Reagents Quantity Code Accessories Code DPD No.1/2/3/ mm cell, 10ml DPD No.1/2/3/ mm cell, 10ml DPD No.1/2/3/ mm cell, 10ml DPD No.1/2/3/4 5 mm cell W680/ COPPER/ZINC LR BT 13.5 mm cell, 10 ml BT COPPER/ZINC HR BT 13.5 mm cell, 10 ml BT Comparator System 2000 HYDR. PEROXIDE HR mm cell, 10 ml ACIDIFYING PT HYDR. PEROXIDE HR 13.5 mm cell, 10 ml ACIDIFYING PT IRON LR (Fe 2+ and Fe 3+ ) BT 13.5 mm cell, 10 ml BT IRON (II) LR (Fe 2+ ) BT IRON HR mm cell, 10 ml Water sampler AF 631, volume 500 ml, total length 85 cm, Order code: Ensures water is sampled at the optimum depth. MANGANESE LR BT 13.5 mm cell, 10 ml BT MANGANESE LR BT BT Combi pack # each BT MANGANESE LR 1/ each BT MANGANESE LR 2 MSDS (Material Safety Data Sheets): 31 Pool & Spa Water Testing - January 2015

32 Comparator Tests, Discs, Reagents, Cells Test Disc Disc Readings Range Code Nitrate 3/142 10; 20; 30; 40; 50; 60; 70; 80; 100 mg/l mg/l NO Ozone (DPD) 3/67 0.1; 0.2; 0.3; 0.4; 0.5; 0.6; 0.7; 0.8; 1 mg/l mg/l Ozone (DPD) 3/67A 0.01; 0.02; 0.03; 0.04; 0.05; 0.06; 0.07; 0.08; 0.1 mg/l mg/l Ozone (Indigo) 3/148 0; 0.05; 0.1; 0.15; 0.2; 0.25; 0.3; 0.4; 0.5 mg/l mg/l ph 2/1G 5.2; 5.4; 5.6; 5.8; 6; 6.2; 6.4; 6.6; ph ph 2/1J 6.8; 7; 7.2; 7.4; 7.6; 7.8; 8; 8.2; ph ph 2/1P 4; 5; 6; 7; 8; 9; 9.4; 10; ph Phosphate 3/136 0; 5; 10; 15; 20; 25; 30; 35; 40 mg/l 0-40 mg/l PO Phosphate 3/70 0; 10; 20; 30; 40; 50; 60; 70; 80; 100 mg/l mg/l PO QAC (Quaternary 3/118 0; 2; 4; 6; 8; 10; 12; 15; 20 mg/l 0-20 mg/l Ammonia Compounds) QAC (Quaternary 3/119 0; 20; 40; 60; 80; 100; 120; 150; 200 mg/l mg/l Ammonia Compounds) Sodiumhypochlorite 3/2 Hypo 2; 4; 6; 8; 10; 12; 14; 16 % 2-16 % also suitable for seawater, # including stirring rod * alternative reagent, used instead of DPD No.1 in case of turbidity in the water sample caused by high concentration of calcium and/or high conductivity Pool & Spa Water Testing - January 2015

33 Reagents Quantity Code Accessories Code NITRATE No BT 13.5 mm cell, 10 ml NITRATE No Combi pack # each Nitrate No.1 / No.2 each DPD No BT 13.5 mm cell, 10 ml BT DPD No BT 40 mm cell W680/ BT OZONE-INDIGO BT 40 mm cell W680/ BT BROMOCRESOL PURPLE mm cell, 10 ml Comparator System 2000 PHENOL RED BT 13.5 mm cell, 10 ml BT UNIVERSAL PH 25 ml mm cell, 10 ml Indicator 100 ml ml ml PHOSPHATE HR BT 13.5 mm cell, 10 ml PHOSPHATE HR BT 13.5 mm cell, 10 ml QAC LR BT 40 mm cell W680/ BT QAC HR mm cell, 10 ml CHLORINE HR (Kl) BT 13.5 mm cell, 10 ml BT ACIDIFYING GP BT BT Combi pack # each BT CHLORINE HR (KI)/ each BT ACIDIFYING GP Dilution set for sample preparation MSDS (Material Safety Data Sheets): 33 Pool & Spa Water Testing - January 2015

34 Photometry MD MD 200 PM 600/620/630 Pool & Spa Water Testing - January 2015

35 Pool & Spa Water Testing - January

36 Photometry The History Several decades have passed since the appearance of the first Lovibond PC 100 photometer system. Since that time, Tintometer has become a world-famous name as the manufacturer of photometer systems sold under the brand name of Lovibond. Our range of photometer systems extends from the MD 100 as hand-held model over the multi parameter photometer MD 200 as desktop model to the SpectroDirect spectrophotometer for laboratories. The multi-functional pm 600, pm 620 & pm 630 photometers provide the answer to all requirements relating to the analysis of water used in modern swimming pools and baths. They offer a wide variety of pre-programmed methods and are therefore suitable for the demands of modern water analysis. All the parameters which can be measured with Lovibond photometer systems are set out in the table. This table also explains what parameters can be measured with which photometer. parameter Acid Capacity KS4.3 Alkalinity-M (total) Aluminium Ammonia Bromine Calcium Hardness Chlorine Chlorine Dioxide Copper Cyanuric acid Hydrogen Peroxide Iodine MD 100 MD 200 PM 620 & PM 630 PM 600 MD 100 MD 200 PM Photometer 36 Pool & Spa Water Testing - January 2015

37 parameter MD 100 MD 200 PM 620 & PM 630 Iron (Fe 2+, Fe 3+ ), soluble Langelier Water Balance Oxygen, active Ozone ph value PHMB (Biguanides) Phosphate PM 600 The photometric principle When specific reagents are added, the water sample takes on a degree of coloration that is proportional to the concentration of the parameter being measured. The photometer measures this coloration. When a light beam passes through the coloured sample, energy with a specific wavelength is absorbed by the test substance. The photometer determines the coloration of the sample by measuring the transmission or absorption of light of this wavelength (in other words, monochromatic light). The photometer then uses a microprocessor to calculate the required concentration and displays the result. Sodium Hypochlorite Sulphate Total Hardness Turbidity (nephelometric), see TB 210 IR page 64 photometry Urea MD 600 SpectroDirect Turbidimeter TB 210 IR 37 Pool & Spa Water Testing - January 2015

38 Photometer Precise Water Analysis in Ergonomic Design Please see pages 50 onwards for reagents (order codes) Highlights Scroll memory Automatic switch-off Real-Time-Clock and date Calibration mode indicator Backlit display Storage function One Time Zero (OTZ) Waterproof *) *) as defined in IP 68, 1 hour at 0.1 meter 38 Pool & Spa Water Testing - January 2015

39 The MD 100 uses high quality interference filters with long-life LEDs as a light source in a transparency sample chamber. The units supply accurate, reproducible results very quickly. Other major advantages include ease of operation, ergonomic design, compact dimensions and safe handling. Using an internal ring memory the last 16 data sets are stored automatically with date, time, parameter and measurement value. The tests are conducted using either Lovibond tablet reagents, with long-term stability and a guaranteed minimum 5 or 10 year shelf life, VARIO powder reagents or using liquid reagents. Scroll Memory To avoid unnecessary scrolling for the required test method, the instrument memorizes the last method used before switching off the instrument. When the instrument is switched on again, the scroll list comes up with the last used test method first. Zero Setting (OTZ) It is not necessary to zero the instrument each time. The zero setting is held in memory until the device is turned off (One Time Zero - OTZ). The zero setting can be confirmed whenever it is required. Please see pages 50 onwards for reagents (order codes) 2in1 4in1 Test Code Chlorine, ph, tablet reagents mg/l Cl 2 / mg/l Cl 2 * ph Chlorine, ph, liquid reagent mg/l Cl 2 / ph Chlorine, ph powder reagents for chlorine mg/l Cl 2 (ø 24 mm glass vial) mg/l Cl 2 (ø 10 mm multi vial-2) ph Test Code Chlorine, ph, Cyanuric Acid, Alkalinity-M (total) tablet reagents mg/l Cl 2 / mg/l Cl 2 * ph ; mg/l cyanuric acid mg/l CaCO 3 (TA) Chlorine, ph, Cyanuric Acid, Alkalinity-M (total) liquid reagent for chlorine and ph mg/l Cl 2 / ph mg/l cyanuric acid / mg/l CaCO 3 (TA) photometry 3in1 Test Code Chlorine, ph, Cyanuric Acid tablet reagents mg/l Cl 2 / mg/l Cl 2 * ph ; mg/l cyanuric acid Chlorine, ph, Cyanuric Acid liquid reagent for chlorine and ph mg/l Cl 2 / ph mg/l cyanuric acid Chlorine, ph, Alkalinity-M (total) tablet reagents mg/l Cl 2 / mg/l Cl 2 * ph ; mg/l CaCO 3 (TA) Chlorine, ph, Alkalinity-M (total) liquid reagent for chlorine and ph mg/l Cl 2 / ph mg/l CaCO 3 (TA) 5in1 Test Code Chlorine, ph, Cyanuric Acid, Alkalinity-M (total), Calcium hardness tablet reagents mg/l Cl 2 / mg/l Cl 2 * ph ; mg/l cyanuric acid mg/l CaCO 3 (TA) ; mg/l CaCO 3 (CaH) 6in1 Test Code Chlorine, Bromine, ph Cyanuric Acid, Alkalinity-M (total), Calcium hardness tablet reagents mg/l Cl 2 / mg/l Cl 2 * mg/l Br ; ph mg/l cyanuric acid mg/l CaCO 3 (TA) ; mg/l CaCO 3 (CaH) * Delivery without reagents for measuring range mg/l Cl 2 39 Pool & Spa Water Testing - January 2015

40 Photometer Technical Data Delivery Content Instrument in carrying case 4 micro batteries (AAA) 3 round vials (glass) with lids 1 stirring rod & 1 brush Tablet reagents and/or liquid reagents or VARIO Powder reagent Warranty information Certificate (Certificate of Compliance) Instruction Manual Manufacturers Test Certificate M Besides the Certificate of Compliance which is supplied with the MD 100, manufacturers test certificates M are available at cost on request. Manufacturers test certificates M are individually supplied per instrument and per method. The manufacturers test certificate M has to be ordered together with the new instrument and cannot be delivered at a later stage. Optics Wavelength Accuracy Photometric Accuracy 4) Photometric Resolution Power Supply Auto - OFF Display Storage Interface Additional feature Calibration LEDs, interference filters (IF) and photo sensor in transparent sample chamber. Depending on the version, up to 3 different interference filters are used. Wavelength specifications of interference filters: 430 nm Δ λ = 5 nm 530 nm Δ λ = 5 nm 560 nm Δ λ = 5 nm 580 nm Δ λ = 5 nm 610 nm Δ λ = 6 nm 660 nm Δ λ = 5 nm ± 1 nm 3% FS (T = 20 C 25 C) 0.01 A 4 micro batteries (AAA), capacity approx. 17 hours or 5000 tests automatic switch-off backlit LCD (on keypress) internal ring memory for 16 data sets infrared interface for test data transfer real time clock and date factory calibration and user calibration. Reset to factory calibration possible Dimensions 155 x 75 x 35 mm (L x W x H) Weight basic unit approx. 260 g Environmental temperature: 5 40 C conditions rel. humidity: 30 90% (non condensing) Approval CE 4) tested with standard solutions Please see pages 50 onwards for reagents (order codes) 40 Pool & Spa Water Testing - January 2015

41 Accessories Item Code Set of 12 round vials with lids Height 48 mm, Ø 24 mm Set of 5 round vials with lids Height 48 mm, Ø 24 mm Set of 12 plastic vials (PC), with lid "Multi"-Type 2, Ø 10 mm Vial stand for 6 round vials Ø 24 mm, acrylic glass Cleaning cloth for vials Measuring beaker, volume 100 ml Cleaning brush, 11 cm length Plastic stirring rod, 13 cm length Plastic stirring rod, 10 cm length micro batteries (AAA) Infrared data transfer module IRiM Data Transfer The optional available IRiM (infrared interface module) uses infrared technology to transmit measurement data from the MD 100 photometer to one of 3 optional interfaces. These interfaces can be used to connect to a PC, a USB printer 1) or alternatively a serial printer 2). The unit is supplied complete with data logging software providing easy and rapid transfer of data to the PC. As an option the data can be saved as an Excel sheet or a.txt file. Measurement data can quickly be printed out, using a specified 1) USB or alternatively a printer with a serial plug-in connected to the IRiM. Applicable for the following operating systems: Windows XP, Windows Vista and Windows 7. 1) USB printer: HP Deskjet 6940 ; 2) each ASCII printer Windows is a registered Trademark of Microsoft Corporation Verification Standard Kit The verification standard kit for the MD 100 is designed to assure the user of the accuracy and the reliability of the results related to the integrated wave lengths. The kit contains one zero standard, 6 different vials for checking 6 different wave lengths and allows for checking the complete range of MD 100 photometers. The shelf life of the verification standard kit is two years from the date of production, provided that storage and use are in accordance with the instructions provided. Measurements are taken in mabs. Verification Standard Kit Reference Standard Kits The reference standards are designed to check the accuracy and the reliability of the results. It is not possible to calibrate the photometer with the reference standards. The shelf life of reference standards is two years from the date of production, provided that storage and use are in accordance with the instructions provided. Kit Chlorine for instruments with tablet / liquid reagent 0.2* and 1.0* mg/l Kit Chlorine for instruments with tablet / liquid reagent 0.5* and 2.0* mg/l Kit Chlorine for instruments with tablet / liquid reagent 1.0* and 4.0* mg/l Kit Chlorine for instruments with powder reagent (VARIO) 0.2* and 1.0* mg/l Kit ph for instruments with tablet / liquid reagent 7,45* ph * Approximate figure, actual figure specified in certificate of analysis enclosed 41 Pool & Spa Water Testing - January 2015

42 200 Photometer Precise results using high-quality interference filters Highlights Scroll memory Automatic switch-off Real-Time-Clock and date Calibration mode indicator Backlit display Storage function One Time Zero (OTZ) Waterproof *) *) as defined in IP 68, 1 hour at 0.1 meter, buoyant 42 Pool & Spa Water Testing - January 2015

43 2in1 4in1 6in1 Test Code Test Code Test Code Chlorine, ph, tablet reagents mg/l Cl 2 / mg/l Cl 2 * ph Chlorine, ph, liquid reagents mg/l Cl 2 / ph Copper, ph tablet reagents mg/l Cu / ph Hydrogen peroxide, ph (no OTZ) liquid reagents 1-50 mg/l H 2 O 2 / mg/l H 2 O ph Chlorine, ph, Cyanuric Acid, Alkalinity-M tablet reagents mg/l Cl 2 / mg/l Cl 2 * ph / mg/l cyanuric acid mg/l CaCO 3 (TA) Chlorine, ph, Cyanuric Acid, Alkalinity-M liquid reagents for chlorine and ph mg/l Cl 2 / ph mg/l cyanuric acid / mg/l CaCO 3 (TA) Chlorine, Chlorine dioxide, ph, Acid capacity KS4.3 tablet reagents mg/l Cl 2 / mg/l ClO ph / mmol/l Chlorine, Bromine, ph, Cyanuric Acid, Alkalinity-M, Calcium hardness tablet reagents mg/l Cl 2 / mg/l Cl 2 * mg/l Br / ph mg/l cyanuric acid / mg/l CaCO 3 (TA) mg/l CaCO 3 (CaH) Chlorine, ph, Cyanuric Acid, Alkalinity-M, Copper, Iron tablet reagents mg/l Cl 2 / mg/l Cl 2 * ph / mg/l cyanuric acid mg/l CaCO 3 (TA) / mg/l Cu mg/l Fe 2+/3+ 3in1 Test Code 5in1 Test Code * Delivery without reagents for measuring range mg/l Cl 2 photometry Chlorine, ph, Bromine tablet reagents mg/l Cl 2 / mg/l Cl 2 * ph / mg/l Br Chlorine, ph, Cyanuric Acid tablet reagents mg/l Cl 2 / mg/l Cl 2 * ph / mg/l cyanuric acid Chlorine, ph, Cyanuric Acid liquid reagents for chlorine and ph mg/l Cl 2 / ph mg/l cyanuric acid Chlorine, ph, Alkalinity-M tablet reagents mg/l Cl 2 / mg/l Cl 2 * ph / mg/l CaCO 3 (TA) Chlorine, ph, Cyanuric Acid, Alkalinity-M, Calcium hardness tablet reagents mg/l Cl 2 / mg/l Cl 2 * ph / mg/l cyanuric acid mg/l CaCO 3 (TA) / mg/l CaCO 3 (CaH) Delivery Content Chlorine, ph, Alkalinity-M liquid reagents for chlorine and ph mg/l Cl 2 / ph mg/l CaCO 3 (TA) Instrument in carrying case 4 batteries (AA) 3 round vials (glass) with lids 1 stirring rod & 1 brush Tablet reagents and/or liquid reagents Warranty information Certificate (Certificate of Compliance) Instruction Manual 43 Pool & Spa Water Testing - January 2015

44 200 Photometer Designed to meet the latest technical requirements, the MD 200 photometer can be used in practically every area of water analysis. The high-precision optics and top-quality interference filters use long-term stable LEDs as light-source. Because there are no moving parts, the entire measurement device requires absolutely no maintenance. Precise and reproducible analysis results are obtained in a short time. The units impress with their user-friendliness, ergonomic design, compact dimensions and easy handling. The tests are conducted using either Lovibond tablet reagents, with long-term stability and a guaranteed minimum 5 or 10 year shelf life, or using liquid reagents. Scroll Memory (SM) For multi-parameter instruments, the order of the various methods is determined. To avoid unnecessary scrolling for the required test method, the instrument memorizes the last method used before switching off the instrument. When the instrument is switched on again, the scroll list comes up with the last used test method first. This allows for faster access to favoured methods. Technical Data Optics Wavelength Accuracy Photometric Accuracy 4) Photometric Resolution Power Supply Auto - OFF Display LEDs, interference filters (IF) and photo sensor in transparent sample chamber. Depending on the version, up to 3 different interference filters are used. Wavelength specifications of interference filters: 430 nm Δ λ = 5 nm 530 nm Δ λ = 5 nm 560 nm Δ λ = 5 nm 580 nm Δ λ = 5 nm 610 nm Δ λ = 6 nm 660 nm Δ λ = 5 nm ± 1 nm 3% FS (T = 20 C 25 C) 0.01 A 4 batteries (AA), capacity approx. 53 hours or tests (continuous operation without display lighting) automatic switch-off backlit LCD (on keypress) Accessories Item Code Set of 12 round vials with lids Height 48 mm, Ø 24 mm Set of 5 round vials with lids Height 48 mm, Ø 24 mm Set of 10 round vials with lid Height 90 mm, Ø 16 mm Adapter for round vials ø 16 mm Vial stand for 6 round vials Ø 24 mm, acrylic glass Vial stand for 10 vials (Ø 16 mm or 13,5 mm), acrylic glass Cleaning cloth for vials Measurement beaker, 100 ml Plastic stirring rod, 13 cm length Plastic stirring rod, 10 cm length Battery lid Batteries (AA) Infrared data transfer module IRiM Zero Setting (OTZ) It is not necessary to zero the instrument each time. The zero setting is held in memory until the device is turned off (One Time Zero - OTZ). The zero setting can be confirmed whenever it is required. Storage Interface Additional feature Calibration internal ring memory for 16 data sets infrared interface for test data transfer to IRiM real time clock and date factory calibration and user calibration. Reset to factory calibration possible Dimensions 190 x 110 x 55 mm (L x W x H) Weight basic unit approx. 455 g (with batteries) Environmental temperature: 5 40 C conditions rel. humidity: 30 90% (non condensing) Approval CE Please see pages 50 onwards for reagents (order codes) 4) tested with standard solutions 44 Pool & Spa Water Testing - January 2015

45 Data Transfer The optional available IRiM (infrared interface module) uses infrared technology to transmit measurement data from the MD 200 photometer to one of 3 optional interfaces. These interfaces can be used to connect to a PC, a USB printer 1) or alternatively a serial printer 2). The unit is supplied complete with data logging software providing easy and rapid transfer of data to the PC. As an option the data can be saved as an Excel sheet or a.txt file. Measurement data can quickly be printed out, using a specified 1) USB or alternatively a printer with a serial plug-in connected to the IRiM. Applicable for the following operating systems: Windows XP, Windows Vista and Windows 7. 1) USB printer: HP Deskjet 6940 ; 2) each ASCII printer Windows is a registered Trademark of Microsoft Corporation Manufacturers Test Certificate M Besides the Certificate of Compliance which is supplied with the MD 200, manufacturers test certificates M are available at cost on request. Manufacturers test certificates M are individually supplied per instrument and per method. The manufacturers test certificate M has to be ordered together with the new instrument and cannot be delivered at a later stage. Verification Standard Kit The verification standard kit for the MD 200 is designed to assure the user of the accuracy and the reliability of the results related to the integrated wave lengths. The kit contains one zero standard, 6 different vials for checking 6 different wave lengths and allows for checking the complete range of MD 200 photometers. The shelf life of the verification standard kit is two years from the date of production, provided that storage and use are in accordance with the instructions provided. Measurements are taken in mabs. Verification Standard Kit Reference Standard Kits The reference standards are designed to check the accuracy and the reliability of the results. It is not possible to calibrate the photometer with the reference standards. The shelf life of reference standards is two years from the date of production, provided that storage and use are in accordance with the instructions provided. Kit Chlorine for instruments with tablet / liquid reagent 0.2* and 1.0* mg/l Kit Chlorine for instruments with tablet / liquid reagent 0.5* and 2.0* mg/l Kit Chlorine for instruments with tablet / liquid reagent 1.0* and 4.0* mg/l Kit ph for instruments with tablet / liquid reagent 7,45* ph * Approximate figure, actual figure specified in certificate of analysis enclosed Photometry Please see pages 50 onwards for reagents (order codes) 45 Pool & Spa Water Testing - January 2015

46 Photometers With Infrared- or Bluetooth data transfer The ultimate range in Pool Photometers For reliable pool relevant water analysis Highlights Intuitive operation Back-lit display User guide in German, English, French, Spanish, Italian, Portuguese, Polish & Indonesian Stores up to 1000 results One Time Zero (OTZ) Infrar-red interface (PM 600 / PM 620) for IRiM data transfer Bluetooth data transfer (PM 630) Waterproof *) *) as defined in IP 68, 1 hour at 0.1 meter Active oxygen Alkalinity-M (total) Aluminium Ammonia Bromine Calcium hardness Chlorine Chlorine dioxide Copper Cyanuric acid Hardness, total Hardness, calcium Hydrogen peroxide Iron Iodine Langelier Index Ozone ph PHMB (Biguanide) Phosphate Sulphate Sodium Hypochlorite Urea Water Balance 46 Assignment of parameters, see pages 36 and 37 Pool & Spa Water Testing - January 2015

47 Photometers PM 600 / PM 620 The PM 600 and PM 620 photometer range brings pool testing to the next level for discerning pool operators. The ergonomic, portable, waterproof design enables users to select just one unit for accurate analysis of up to 34 parameters anytime and anyplace. The pm 600 focusses on the main pool parameters required for balanced water including: Alkalinity, Bromine, Chlorine, Cyanuric Acid, Iron, Calcium Hardness, Copper, Sodium Hypochlorite, Ozone and ph-value. Compatible with the tried and trusted Lovibond Tablet reagents, it is designed to be robust, reliable yet easy-to-use for any pool operator. The pm 620 extends these capabilities to include up to 34 parameter variants from Acid Demand to Urea. Its unique design enables compatibility with Lovibond Tablet, Liquid and Powder reagents, making it one of the most flexible and complete pool photometers available today. Both units offer a large, back-lit graphic display to aid analysis by providing on-screen method prompts, information regarding test measurement range and reagent type and automatic countdown timers for accurate reaction periods. The internal memory is capable of storing up to 1000 results with date, time and sample ID. These results can be reviewed at any time and can be downloaded to a PC via an additional Infra-Red module (IRiM) *. Supplied in a durable, portable case complete with accessories and space for additional reagents, both photometers provide immediate access to the accurate water analysis expected of the Lovibond brand, clearly the best choice for water analysis. * available as an option : IRiM (infrared interface Photometer PM 630 The PM 630 introduces data management and Bluetooth functionality to the highly proven PM 600 series of photometers. Already simplifying accurate water analysis with 34 pre-calibrated pool methods, the series has now been expanded to include Bluetooth data transmission. Now, results can be quickly and easily transferred to smartphones and tablets. The system is further enhanced by the free Lovibond App, AquaLX, enabling the immediate review, process and evaluation of measured results directly on-site. Data trends can be monitored with easy-to-view graphical displays with set minimum and maximum values. Any fluctuation to expected results is immediately visible and instant action can be taken. GPS activated, AquaLX also recognises and saves the exact location of the photometer. Furthermore, additional personalized information, such as the name of the pool and the pool engineer can be recorded, providing a complete information record of the measurement. Technical Data Display Interfaces Optics Wavelength Accuracy Photometric Accuracy* Photometric Resolution Operation Power Supply Auto-Off Dimensions Graphic-display Infrared interface for test data transfer 1, RJ45 socket for Internet updates 2 LEDs, interference filters (IF) and photo sensor in transparent sample chamber ± 1 nm 2% FS (T = 20 C 25 C) A Acid and solvent resistant, touch-sensitive keypad with audible feedback via integrated beeper 4 batteries (Mignon AA/LR6); Operation time: approx. 26 h continuous operation or 3500 tests approx. 20 minutes after last keypress with audible signal approx. 210 x 95 x 45 mm (unit) approx. 395 x 295 x 106 mm (case) approx. 450 g Weight (unit) Ambient 5 40 C at max % Conditions rel. humidity (non condensing) Language Selection Memory Capacity Approval German, English, French, Spanish, Italian, Portuguese, Polish, Indonesian ; additional languages via Internet update approx data sets CE 1 optional available: IRiM (Infrared Interface Modul) 2 optional available: connection cable with integrated electronics (RS 232 / RJ-45 plug) * tested with standard solutions Records can be transferred at the touch of a button by either as a graphic or database record, simplifying the transfer, management and sharing of results. AquaLX compliments the Langelier Index App, PoolM8, which negates the need for complex calculations for Balanced Water. By simply entering the results of the parameters (ph; Total Alkalinity; Calcium Hardness; Total Dissolved Solid; Temperature.), the App automatically determines and displays the results which can then be saved to create a history and, again, shared via . Both Lovibond Apps are available for Android and ios. Please see pages 50 onwards for reagents (order codes) Reference Standard Kits The reference standards are designed to check the accuracy and the reliability of the results. It is not possible to calibrate the photometer with the reference standards. The shelf life of reference standards is two years from the date of production, provided that storage and use are in accordance with the instructions provided. Reference Standard Kit Chlorine * and 1.0* mg/l for tablet and VARIO methods 1) Reference Standard Kit Chlorine * and 2.0* mg/l for tablet methods only Reference Standard Kit Chlorine * and 4.0* mg/l for tablet methods only Reference Standard Kit ph * ph * Approximate figure, actual figure specified in certificate of analysis enclosed 1) The standard values mentioned in kit for the VARIO method are for photometer PM 620 only, because this method is not available in the PM 600 Verification Standard Kit The verification standard kit for the PM 600 and PM 620 is designed to assure the user of the accuracy and the reliability of the results related to the integrated wave lengths. The shelf life of the verification standard kit is two years from the date of production, provided that storage and use are in accordance with the instructions provided. Measurements are taken in mabs. Verification Standard Kit Delivery Content Instrument in carrying case 4 batteries (AA) 3 round vials 24 mm ø 1 syringe, 1 brush, 1 stirring rod 1 plastic beaker 100 ml Warranty information Certificate of Compliance Instruction Manual pm 600 (13 parameter, infrared) 100 tablet reagents each for chlorine (free, combined, total), ph value, calcium hardness, alkalinity-m Order code: pm 620 (34 parameter, infrared) 100 tablet reagents each for chlorine (free, combined, total), ph value, cyanuric acid, alkalinity-m Order code: pm 630 (34 parameter, Bluetooth) 100 tablet reagents each for chlorine (free, combined, total), ph value, cyanuric acid, alkalinity-m Order code: photometry 47 Pool & Spa Water Testing - January 2015

48 Reagents History For several decades, Tintometer has been manufacturing reagents for water testing and marketing these reagents around the world under the brand name Lovibond. Different forms of reagents are required for different fields of application. It is fair to say that, in terms of quality, tablet reagents are the best form of reagent. Thanks to production techniques of the type used in the pharmaceutical industry and stringent internal quality standards, Tintometer is able to produce tablet reagents for water testing with a guaranteed shelf life of 5 or 10 years. These tablets are individually sealed in high-grade, polyethylene-coated aluminium foil and represent the reagent form of choice for everyday water testing applications. Users in different countries traditionally prefer forms of reagent other than tablets. Lovibond powder reagents are designed to allow fast and easy testing. Powder reagents are packed in aluminium foil for a wide range of applications and represent an alternative reagent form recently introduced by Tintometer. Last but not least, liquid reagents are indispensable for many testing tasks. Testing for substances that are hard to detect, for parameters like total nitrogen, or for the aggregate parameter COD, require the use of a wide range of reagents in a form that permits more "aggressive sample processing. The Lovibond programme is rounded off by reagent tests and tube tests, making Tintometer the only reagent producer in the world that offers a complete range of reagent forms. Tablets The test tablets are manufactured in Germany under tightly controlled conditions on the latest machinery. Maintaining the highest quality standards permits Tintometer to guarantee our tablet reagents for a minimum of 5 years, and some for as long as 10 years. We can make this promise because each tablet is hermetically sealed, protecting against challenging environmental conditions. This packaging keeps each tablet in perfect condition, right up until the time it is needed by the user. Test tablets remain the most consistent and reliable reagent format available, consistently outperforming other reagent formats, and delivering maximum accuracy for the user. The aluminium foil blister packaging brings added convenience to the tradition of protection achieved in the Lovibond long established tablet production technology. With the blister strip, the user just pushes the tablet through the protective foil, straight into the sample. Simple, time-saving and practical. This type of packaging, long established in pharmaceutical applications, combines all the advantages of protective foil, with convenience for the user. Each tablet is contained within an individually formed foil cup, lined with the latest aluminium composite material, and guaranteeing product performance. There are no safety risks if the tablets are used in line with the instructions supplied. Safety data sheets are available for all reagents. Specification and Certificate of Analysis To express the high quality standard of Lovibond tablet reagents, specification for each type of tablet as well as a Certificate of Analysis for each lot is available in the down-load area at Liquids As a rule, liquid reagents do not consist of a single preparation but comprise several components that need to be added to the sample in a certain order. As both the size and the number of drops have a decisive effect on the resultant colour complex, the reagents need to be added with a high degree of precision. The useful life of liquid reagents is reduced by temporary contact with oxygen in the air when the bottle is opened as well as by unsuitable storage environments (presence of sunlight or high temperatures). Provided that the bottles are stored within the temperature range +6 C to +10 C, the Lovibond DPD and Phenol Red solutions can be used for a period of two years from the production date Pool & Spa Water Testing - January 2015

49 VARIO Powder Packs The fast and easy use of VARIO Powder Packs has made them extremely popular for water testing applications in many countries throughout the world. The Lovibond Powder Pack programme provides users with a real alternative to existing measurement systems. The Vario Powder Packs are produced to the same high quality standards that have made Tintometer's tablet reagents so successful for several decades. Parameters from aluminium and chlorine through to sulphate are just some of the well-known tests that are included in the VARIO Powder Pack range. Membrane filter set For use when preparing samples for photometric measurements, e.g. for water analysis in natural swimming ponds. Advantage removes turbid materials from samples 0.45 µm mesh meets the requirements of the official German unitary procedure for water testing To prevent the effects of light scatter, it must be ensured that all turbid materials are removed from the sample before photometric measurements are carried out. This can be achieved with the Lovibond membrane filter set. Order code: (covers 25 x 0.45 µm membrane filters and two 20 ml syringes) Determination of Chlorine, Chlorine Dioxide, Bromine and Ozone with Lovibond Tablet Reagents Free Chlorine DPD No.1-Tablet (direct reading of the value) Combined Chlorine DPD No.1-Tablet (free Chlorine = A) + DPD No.3-Tablet (total Chlorine = B) Difference between B and A = Combined Chlorine Total Chlorine DPD No.4-Tablet (direct reading of the value) or DPD-Tablets No.1 and No.3 together Chlorine Dioxide DPD No.1-Tablet and DPD No.3-Tablet and Chlorine Dioxide in Glycine-Tablet presence of Residual Chlorine Bromine DPD No.1-Tablet Ozone DPD No.4-Tablet Ozone in presence of Chlorine DPD No.4-Tablet Glycine-Tablet photometry 49 Pool & Spa Water Testing - January 2015

50 Reagents Wavelength λ / nm Test Range Method Cuvette MD 100 MD 200 PM 600 PM 620 & PM 630 Acid capacity KS mmol/l Acid/Indicator 1, 2 24 mm ø Tablets Alkalinity-M (total) mg/l Acid/Indicator 1, 2, 5 24 mm ø Tablets Alkalinity-M HR mg/l Acid/Indicator 1, 2, 5 24 mm ø Tablets Aluminium mg/l Eriochrome cyanine R 2 24 mm ø Powder reagent Aluminium mg/l Eriochrome cyanine R 2 24 mm ø Tablets Ammonia mg/l Indophenole blue 2, 3 24 mm ø Tablets Ammonia VARIO mg/l Salicylate 2 24 mm ø Powder reagent Biguanide (see PHMB) Bromine mg/l DPD 5 24 mm ø Tablets Chlorine a) mg/l DPD 1, 2 24 mm ø Tablets Chlorine HR (DPD) a) mg/l DPD 1, 2 24 mm ø Tablets Chlorine a) mg/l DPD 1, 2 24 mm ø Liquid reagent MSDS (Material Safety Data Sheets): For other reagent quantities please see our current price list. Legend 1 Deutsche Einheitsverfahren zur Wasser-, Abwasser- und Schlamm- Untersuchung 2 Standard Methods for the Examination of Water and Wastewater, 18th Edition; Photometrische Analysenverfahren, Schwedt, Wissenschaftliche Verlagsgesellschaft mbh, Stuttgart; Photometrische Analyse, Lange/Vejdelek, Verlag Chemie; Colorimetric Chemical Analytical Methods, 9th Edition, Lovibond 50 Pool & Spa Water Testing - January 2015

51 Display Reagent Form of reagent/quantity Order code ALKA-M-PHOTOMETER Tablet / BT CaCO 3 ALKA-M-PHOTOMETER Tablet / BT CaCO 3 ALKA-M-HR-PHOTOMETER Tablet / BT Al VARIO Aluminum ECR/F20 Powder Pack / 100 VARIO Aluminum Hexamine/F20 Powder Pack / 100 VARIO Aluminum ECR Masking Reagent Liquid reagent / 25 ml Set Al ALUMINIUM No. 1 Tablet / BT ALUMINIUM No. 2 Tablet / BT Combi pack # ALUMINIUM No.1 / No.2 each BT Combi pack # ALUMINIUM No.1 / No.2 each BT N AMMONIA No. 1 Tablet / BT AMMONIA No. 2 Tablet / BT Combi pack # AMMONIA No.1 / No.2 each BT Combi pack # AMMONIA No.1 / No.2 each BT Ammonia conditioning powder (for seawater) Powder / 15 g / 50 Tests Photometry N VARIO Ammonia Salicylate F10 Powder Pack / 100 VARIO Ammonia Cyanurate F10 Powder Pack / 100 Set Br DPD No. 1 Tablet / BT DPD No. 1 HIGH CALCIUM e) Tablet / BT GLYCINE f) Tablet / BT Cl 2 DPD No. 1 Tablet / BT DPD No. 3 Tablet / BT Combi pack # DPD No.1 / No.3 each BT Combi pack # DPD No.1 / No.3 each BT DPD No. 1 HIGH CALCIUM e) Tablet / BT DPD No. 3 HIGH CALCIUM e) Tablet / BT Combi pack # DPD No.1 / No.3 HIGH CALCIUM e) each BT Combi pack # DPD No.1 / No.3 HIGH CALCIUM e) each BT Cl 2 DPD No. 1 HR Tablet / BT DPD No. 3 HR Tablet / BT Cl 2 DPD 1 Buffer solution Liquid reagent / 15 ml DPD 1 Reagent solution Liquid reagent / 15 ml DPD 3 Solution Liquid reagent / 15 ml Set a) determination of free, combined and total e) alternative reagent, used instead of DPD No.1 / DPD No.3 in case of turbidity in the water sample caused by high concentration of calcium and/or high conductivity f) additionally required for determination of bromine, chlorine dioxide and ozone in the presence of chlorine g) Reagent recovers most insoluble iron oxides without digestion h) additionally required for samples with hardness values above 300 mg/l CaCO 3 i) high range by dilution # including stirring rod 51 Pool & Spa Water Testing - January 2015

52 Reagents Wavelength λ / nm Test Range Method Cuvette MD 100 MD 200 PM 600 PM 620 & PM 630 Chlorine a) mg/l DPD 1, 2 24 mm ø Powder reagent mg/l mm ø multy vial Chlorine dioxide mg/l DPD/Glycine 1,2 24 mm ø Tablets Copper a) mg/l Biquinoline 4 24 mm ø Tablets Copper, free VARIO 0,05-5 mg/l Bicinchoninate 24 mm ø Powder reagent Cyanuric acid mg/l i) Melamine 24 mm ø Tablets Hardness, calcium mg/l Murexid 4 24 mm ø Tablets Hardness, total 2-50 mg/l Metallphthalein 3 24 mm ø Tablets mg/l i) Hydrogen peroxide 1-50 mg/l Peroxotitanium acid 24 mm ø Liquid reagent mg/l i) Iodine mg/l DPD 5 24 mm ø Tablets Iron (II, III) mg/l PPST 3 24 mm ø Tablets Oxygen, activ mg/l DPD Tablets Ozone mg/l DPD/Glycine 5 24 mm ø Tablets MSDS (Material Safety Data Sheets): For other reagent quantities please see our current price list. Legend 1 Deutsche Einheitsverfahren zur Wasser-, Abwasser- und Schlamm- Untersuchung 2 Standard Methods for the Examination of Water and Wastewater, 18th Edition; Photometrische Analysenverfahren, Schwedt, Wissenschaftliche Verlagsgesellschaft mbh, Stuttgart; Photometrische Analyse, Lange/Vejdelek, Verlag Chemie; Colorimetric Chemical Analytical Methods, 9th Edition, Lovibond 52 Pool & Spa Water Testing - January 2015

53 Display Reagent Form of reagent/quantity Order code Cl 2 VARIO Chlorine FREE-DPD/F10 Powder Pack / VARIO Chlorine TOTAL-DPD/F10 Powder Pack / ClO 2 DPD No. 1 Tablet / BT DPD No. 3 Tablet / BT Combi pack # DPD No.1 / No.3 each BT Combi pack # DPD No.1 / No.3 each BT GLYCINE f) Tablet / BT Combi pack # DPD No.1 / GLYCINE each BT Combi pack # DPD No.1 / GLYCINE each BT DPD No.1 High Calcium e) Tablet / BT Cu COPPER No. 1 Tablet / BT COPPER No. 2 Tablet / BT Combi pack # COPPER No.1 / No.2 each BT Combi pack # COPPER No.1 / No.2 each BT Cu Vario Cu 1 F10 Powder Pack / CyA CyA-TEST Tablet / BT CaCO 3 Combi pack # CALCIO H No.1 / No.2 each BT Combi pack # CALCIO H No.1 / No.2 each BT Photometry CaCO 3 HARDCHECK P Tablet / BT Tablet / BT H 2 O 2 H 2 O 2 reagent solution Liquid reagent / 15 ml I DPD No. 1 Tablet / BT Fe IRON LR (Fe 2+ and Fe 3+ ) Tablet / BT IRON (II) LR (Fe 2+ ) Tablet / BT O 2 DPD No. 4 Tablet / BT O 3 DPD No. 1 Tablet / BT DPD No. 3 Tablet / BT Combi pack # DPD No.1 / No.3 each BT Combi pack # DPD No.1 / No.3 each BT GLYCINE f) Tablet / BT Combi pack # DPD No.1 / GLYCINE each BT Combi pack # DPD No.1 / GLYCINE each BT a) determination of free, combined and total e) alternative reagent, used instead of DPD No.1 / DPD No.3 in case of turbidity in the water sample caused by high concentration of calcium and/or high conductivity f) additionally required for determination of bromine, chlorine dioxide and ozone in the presence of chlorine g) Reagent recovers most insoluble iron oxides without digestion h) additionally required for samples with hardness values above 300 mg/l CaCO 3 i) high range by dilution # including stirring rod 53 Pool & Spa Water Testing - January 2015

54 Reagents Wavelength λ / nm Test Range Method Cuvette MD 100 MD 200 PM 600 PM 620 & PM 630 PHMB (Biguanide) 2-60 mg/l Buffer/Indicator 24 mm ø Tablets Phosphate LR, ortho mg/l Phosphomolybdic acid/ 24 mm ø Tablets Ascorbic acid 2 ph value Bromcresol purple 5 24 mm ø Tablets ph value Phenol red 5 24 mm ø Tablets ph value Phenol red 5 24 mm ø Tablets ph value Thymol blue 5 24 mm ø Tablets Sodiumhypochlorite % Potassium iodide 5 24 mm ø Tablets Sulphate VARIO mg/l Bariumsulphate Turbidity 2 24 mm ø Powder reagent Sulphate mg/l Bariumsulphate Turbidity 2 24 mm ø Tablets Urea mg/l Urease / Indophenol 24 mm ø Tablets / Liquid reagent mg/l i) MSDS (Material Safety Data Sheets): For other reagent quantities please see our current price list. Legend 1 Deutsche Einheitsverfahren zur Wasser-, Abwasser- und Schlamm- Untersuchung 2 Standard Methods for the Examination of Water and Wastewater, 18th Edition; Photometrische Analysenverfahren, Schwedt, Wissenschaftliche Verlagsgesellschaft mbh, Stuttgart; Photometrische Analyse, Lange/Vejdelek, Verlag Chemie; Colorimetric Chemical Analytical Methods, 9th Edition, Lovibond 54 Pool & Spa Water Testing - January 2015

55 Display Reagent Form of reagent/quantity Order code PHMB PHMB PHOTOMETER Tablet / BT PO 4 PHOSPHATE No. 1 LR Tablet / BT PHOSPHATE No. 2 LR Tablet / BT Combi pack # PHOSPHATE No.1 LR / No.2 LR each BT ph BROMOCRESOLPURPLE/PHOTOMETER Tablet / BT ph PHENOLRED / PHOTOMETER Tablet / BT ph PHENOLRED Solution Liquid reagent / 15 ml ph THYMOLBLUE / PHOTOMETER Tablet / NaOCl ACIDIFYING GP Tablet / BT CHLORINE HR (KI) Tablet / Combi pack # CHLORINE HR (KI)/ACIDIFYING GP each BT Combi pack # CHLORINE HR (KI)/ACIDIFYING GP each BT Photometry SO 4 VARIO Sulpha 4 / F10 Powder Pack / SO 4 SULFATE T Tablet / BT CH 4 N 2 O UREA Reagent 1 Liquid reagent / 15 ml UREA Reagent 2 Liquid reagent / 10 ml AMMONIA No. 1 Tablet / AMMONIA No. 2 Tablet / Combi pack # AMMONIA No.1 / No.2 each Combi pack # AMMONIA No.1 / No.2 each UREA PRETREAT (compensates for the interference of free Chlorine up to 2 mg/l) Tablet / BT a) determination of free, combined and total e) alternative reagent, used instead of DPD No.1 / DPD No.3 in case of turbidity in the water sample caused by high concentration of calcium and/or high conductivity f) additionally required for determination of bromine, chlorine dioxide and ozone in the presence of chlorine g) Reagent recovers most insoluble iron oxides without digestion h) additionally required for samples with hardness values above 300 mg/l CaCO 3 i) high range by dilution # including stirring rod 55 Pool & Spa Water Testing - January 2015

56 Natural Swimming Ponds A natural swimming pond looks like a natural garden pond, but is specifically designed to swim in clean, pure water with no chemicals in it. The difference between a swimming pond and a swimming pool is that a swimming pool uses chemicals such as chlorine to kill bacteria, whereas a swimming pond cleanses the water naturally. It uses the purifying properties of plants, a filter to extract surface debris such as leaves, and a pump to keep the water circulating through the planting area. Nevertheless, the water quality has to be checked regularly to make sure that the bathers are safe under all circumstances, e.g. microorganism and other biological, chemical and physical components. Chemical Requirements for fresh water - possibly after preconditioning* Parameter Guide Value Alkalinity-m 100 mg/l CaCO 3 Ammonia 0.5 mg/l Conductivity 1000 µs/cm at 20 C Hardness 1.0 mmol/l Iron 0.2 mg/l Manganese 0.05 mg/l Nitrate 50.0 mg/l ph value Total Phosphate 0.01 mg/l Chemical and physical guide values for basin water* Parameter Guide Value Alkalinity-m 100 mg/l CaCO 3 Ammonia 0.3 mg/l Conductivity µs/cm at 25 C Hardness 1.0 mmol/l Nitrate 30.0 mg/l Oxygen saturation % ph value (Exception to ph 9.0) Total Phosphate 0.01 mg/l Visibility depth to the ground or min m Water temperature 25 C, up to 5 days max. 28 C * Forschungsgesellschaft Landschaftsentwicklung Landschaftsbau e.v. (FLL). Richtlinien für Planung, Bau, Instandhaltung und Betrieb von Freibädern mit biologischer Wasseraufbereitung (Schwimm- und Badeteiche), Ausgabe Photo: swimming-teich.com Pool & Spa Water Testing - January 2015

57 Bathing Water This applies to any water where the authorities expect a large number of people to bathe and has not imposed a permanent bathing prohibition, or issued advice against bathing. It is the responsibility of the authorities to identify and assess causes of pollution that might affect bathing waters and impair bathers health during the bathing season. The basis for the control of all public used natural swimming ponds is the European Directive "2006/7/EG of the European Parliament, dated 15th February The Directive is valid since 24th March Microbiology Escherichia coli Enterococci Pseudomonas aeroginosa Legionella pneumophila Cyano bacteria Parasites e.g. Cryptosporidia Photo: Grafinger, Chemical and physical characteristics Dissolved Oxygen Dissolved oxygen is probably the most critical quality variable in the water. Oxygen levels in pond systems depend on water temperatures, the water salinity, and the amount of aquatic vegetation and animals. ph-value The ph-value is the determination of the hydrogen ion (H + ) concentration in water. The ph scale ranges from 0-14 with a ph of 7 being neutral. A ph below 7 is acidic and a ph of above 7 is basic. An optimal ph range is between 6.5 and 8.5, however it should not be lower than ph5 or above ph9. ph will vary depending on a number of factors. The ph may rise during the day as phytoplankton and other aquatic plants remove CO 2 from the water during photosynthesis. The ph decreases at night because of respiration and production of CO 2 by organisms. The fluctuation of ph levels will depend on algae levels as well. Temperature Temperature will affect all chemical and biological processes. Temperature therefore has a direct effect on important factors such as growth and oxygen demand. The higher the temperature, the greater the requirement for oxygen and the faster the growth rate of the plants. Ammonia Ammonia is produced from the decomposition of organic wastes resulting in the breakdown of decaying organic matter such as algae and plants. Ammonia levels will depend on the temperature of the water and its ph. For example at a higher temperature and ph, a greater number of ammonium ions are converted into ammonia gas thus causing an increase in toxic ammonia levels within the freshwater. Nutrient levels Nutrient levels refer to the amount of phosphorus and nitrogen that are present in the water. Increased levels of nutrients may be harmful. It can cause excessive plankton growth, potential blue-green algae and oxygen depletion. See Lovibond General Catalogue, no.: Order your free copy! See page 70 Turbidity page 64 Test methods for a.m. parameter see index page 70 and 71. Natural Swim. Ponds Membrane filter set for sample preparation, see page Pool & Spa Water Testing - January 2015

58 SD Series (IP 67 waterproof) The new Lovibond SD series comprises a range of compact, easy-to-use, hand-held instruments for the accurate measurement of ph, ORP, Con, TDS or Salt. With robust housing and fully waterproof (IP67) casing, these testers are the ideal solution for in-situ testing in environmental, industrial or pool & spa applications. The intuitive scroll-bar functionality and backlit display enable the easy measurement and simultaneous display of Result I Temperature I Date & Time I Other Measurement Details. With 25 sets of data storage, each with date and time stamp, the units also enable the easy recalling of data for record keeping requirements. Designed and manufactured according to Lovibond quality standards, the devices are equipped with replaceable electrodes to ensure long-life functionality in the field. Highlights Scroll-Through Functionality Compact & Robust Storage Function Backlit Display Waterproof (IP67) Delivery Content Meter in a robust plastic case with hanger Batteries / without batteries (depending on the order code) Lanyard Instruction Manual SD 50 ph additionally: ph 4, 7, 10 buffer tablets (1 strip of 10 tablets each) 58 Pool & Spa Water Testing - January 2015

59 Technical Specifications SD Hand-Held Meter SD 50 ph Range Resolution 0-60 C, 0-14 ph 0.01 ph Accuracy ± 0.05 ph Resolution 0.1 C; Accuracy: ± 1 C, temperature selectable C / F system Selectable ph 7.00 or ph 6.86 buffer system Calibration 1, 2, or 3 points calibration with auto-recognition (NIST / IUPAC) Temperature compensation Memory Display Power supply Battery life Auto-off Approval Order code Automatic Spare electrode SD 80 TDS Time and date display / stamp with 25 sets of data storage (non-volatile) 22 x 22 mm LCD screen, with yellow/green backlight 2 x CR2032 batteries > 25 hours (continuous use, backlight OFF), low battery indicator on LCD screen 8 minutes non-use CE without batteries B with batteries Range 0-60 C, < ppt 2) Resolution 1 ppm (<= 999 ppm) 0.01 ppt ( ppt) Accuracy ± 3 % FS Resolution 0.1 C; Accuracy: ± 1 C, temperature selectable C / F system Auto switch over ppm: ppm and ppt ppt: Calibration Temperature compensation Memory Display Power supply Battery life Auto-off Approval Order code Spare electrode up to 2 points calibration manual mode ± 50 % adjustable value Automatic Time and date display / stamp with 25 sets of data storage (non-volatile) 22 x 22 mm LCD screen, with yellow/green backlight 2 x CR2032 batteries > 25 hours (continuous use, backlight OFF), low battery indicator on LCD screen 8 minutes non-use CE without batteries B with batteries SD 60 ORP Range Resolution Accuracy Resolution temperature Calibration Temperature compensation Memory Display Power supply Battery life Auto-off Approval Order code 0-60 C, ~ 1800mV 0.1 mv (within ± 1000 mv) 1 mv (outside ± 1000 mv) ± 20 mv 0.1 C; Accuracy: ± 1 C, selectable C / F system 1 point calibration with ± 150 mv adjustable ORP value Automatic Spare electrode SD 90 Salt Time and date display / stamp with 25 sets of data storage (non-volatile) 22 x 22 mm LCD screen, with yellow/green backlight 2 x CR2032 batteries > 25 hours (continuous use, backlight OFF), low battery indicator on LCD screen 20 minutes non-use CE without batteries B with batteries Range 0-60 C, < ppt =^ 2.00 % 3) Resolution 0.01 % (when set to "P" % unit) 1 ppm (< 2000 ppm) 0.01 ppt ( ppt) Accuracy ± 3 % FS Resolution 0.1 C; Accuracy: ± 1 C, temperature selectable C / F system Auto switch over ppm: ppm and ppt ppt: Calibration up to 2 points calibration manual mode ± 50 % adjustable value Selectable "P" % or unit system ppt / ppm Temperature compensation Memory Display Power supply Battery life Auto-off Approval Order code Automatic Spare electrode Time and date display / stamp with 25 sets of data storage (non-volatile) 22 x 22 mm LCD screen, with yellow/green backlight 2 x CR2032 batteries > 25 hours (continuous use, backlight OFF), low battery indicator on LCD screen 8 minutes non-use CE without batteries B with batteries SD 70 Con Range 0-60 C, < ms 1) Resolution 1 µs (<= 1999 µs) 0.01 ms ( ms Accuracy ± 3 % FS Resolution 0.1 C; Accuracy: ± 1 C, temperature selectable C / F system Auto switch µs: over µs and ms ms: Calibration 1 or 2 points calibration for auto mode Standard: 1413 µs or Standard: ms up to 2 points calibration for manual mode ± 50 % adjustable value Temperature Automatic compensation Memory Time and date display / stamp with 25 sets of data storage (non-volatile) Display 22 x 22 mm LCD screen, with yellow/green backlight Power supply 2 x CR2032 batteries Battery life > 25 hours (continuous use, backlight OFF), low battery indicator on LCD screen Auto-off 8 minutes non-use Approval CE Order code without batteries B with batteries Spare electrode Conversion table 1) ms/cm = 0-20,000 µs/cm 2) ppt TDS = 0-10,000 ppm TDS 3) ppt NaCl = 0-20,000 ppm NaCl ppt NaCl = 0-2 % NaCl ppt NaCl = 0-20 g/l NaCl ppm = Parts per Million = mg/l ppt = Parts per Thousand = g/l 59 Pool & Spa Water Testing - January 2015

60 Determination of: ph (0-14) Conductivity (ms/cm) Salinity (%) 60 Pool & Spa Water Testing - January 2015

61 ph110 Con110 Salt110 The SensoDirect ph110 is a high quality, portable, battery operated ph meter. The instrument is equipped as standard with protective casing and built-in electrode holder. The gel electrode of the SensoDirect ph110 is temperature resistant over the range 0-80 C. It is fitted with a BNC connector as standard. Technical data ph110 Range Resolution Temperature compensation Accuracy 0-14 ph 0.01 ph not necessary ± 0.07 ph (ph5-ph9) ± 0.1 ph (ph4-ph10) ± 0.2 ph (ph1-ph3.9) ± 0.2 ph (ph10,1-ph13) 23 ± 5 C, after calibration Ambient 0-50 C conditions 0-80 % rel. humidity (non condensing) Battery 9 V block Dimensions 208 x 110 x 34 mm (L x W x H) Weight approx. 380 g Approval CE Order Code The SensoDirect Con110 is a compact and versatile meter. The unit is extremely easy to use and is equipped as standard with a protective casing and built-in electrode holder. It is equipped with a LC display showing two or three decimal places and a measuring range either of or ms/cm. As conductivity measurement also depends on temperature, the SensoDirect Con110 includes an automatic temperature compensation feature. The SensoDirect Con110 can be calibrated and adjusted using a potentiometer. The SensoDirect Salt110 provides fast, accurate readings and the convenience of a remote probe separately. The measuring range of this salt tester is 0 to 10 % salt ( % weight ). The SensoDirect Salt110 includes an automatic temperature compensation feature. The unit is extremely easy to use and is equipped as standard with a protective casing and built-in electrode holder. Accessories SensoDirect ph110 Code Article ph-electrode plastic/gel, type ph ph-buffer, 4.00 (25 C), 90 ml ph-buffer, 7.00 (25 C), 90 ml ph-buffer, (25 C), 90 ml Technical data Con110 Range ms/cm ms/cm Resolution / 0.01 ms/cm Temperature C automatically compensation 2 %/K, 25 C Accuracy ± 3 % Full Scale ± 1 Digit (23 ± 5 C) Ambient 0-50 C conditions 0-80 % rel. humidity (non condensing) Battery 9 V-Block Dimensions 208 x 110 x 34 mm (L x W x H) Weight approx. 380 g Approval CE Order code Accessories SensoDirect Con110 Code Article Conductivity calibration solution, 1413 µs/cm, 500 ml Technical data Salt110 Range 0-10 % Salt Resolution 0,01 % Salt Temperature 0-50 C, automatically compensation Accuracy ± 0,5 % (23 ± 5 C) Ambient 0-50 C conditions 0-80 % rel. humidity (non condensing) Battery 9 V-Block Dimensions 208 x 110 x 34 mm (L x W x H) Weight approx. 380 g Approval CE Order code electrochemistry Delivery content Delivery content Delivery content SensoDirect ph110 in a sturdy plastic case SensoDirect Con110 in a sturdy plastic case SensoDirect Salt110 in a sturdy plastic case Battery Battery Battery ph-buffer (4.00/7.00) Conductivity sensor Sensor ph-plastic electrode-type 110 Warranty information Warranty information Warranty information Instruction manual Instruction manual Instruction manual 61 Pool & Spa Water Testing - January 2015

62 150 ph value Redox Oxygen (dissolved) Conductivity TDS Temperature ( C / F) All in one Hand-held Meter The SensoDirect 150 combines the features of several hand-held meters. It is designed for multi purpose operation and measures ph/redox, dissolved oxygen and conductivity/tds. The SensoDirect 150 incorporates an intuitive user interface, large, easy to read display and is supplied with a sturdy handy case with electrodes, buffer solution and accessories Pool & Spa Water Testing - January 2015

63 SensoDirect 150 Display Large LCD display with contrast adjustment Parameter ph: 0 to ph ORP: ± 1999 mv Conductivity: 200 µs / 2 ms / 20 ms / 200 ms TDS (Total Dissolved Solids): Dissolved Oxygen: 0 to 20.0 mg/l Data Logger Real time data logger Data Memory Auto or manual data memory, data sets Data Hold Max, Min Interface USB, RS232 Probes ph, ORP, Conductivity/TDS, Dissolved Oxygen and Temperature Power off Auto shut off or manual off Data Output RS 232 PC serial interface Power Supply DC 1,5 V battery ( UM3, AA) x 4 PCs or DC 9V adapter in Software Data acquisition software Data logger software Dimensions 220 x 120 x 40 mm (L x B x H) Weight approx. 625 g (Instrument with batteries) Approval CE ph/redox/temperature Range ph 0 to 14 PH mv mv to 1999 mv Resolution 0-14 ph, 0.01 ph mv, 1 mv Accuracy 0-14 ph, ± 0.02 ph + 2 digits mv, ± 0.5 % + 2 digits Temperature manual C Compensation automatic (ATC) ph ph 7, ph 4, and ph10, Calibration 3 points calibration Dissolved Oxygen/Temperature Conductivity/TDS/Temperature Range/ Conductivity (µs, ms) Resolution µs / 0.1 µs ms / ms ms / 0.01 ms ms / 0.1 ms TDS (Total Dissolved Solids) ppm / 0.1 ppm 132-1,320 ppm / 1 ppm 1,320-13,200 ppm / 10 ppm 13, ,000 ppm / 100 ppm Temperature 0-60 C / 0.1 C F / 0.1 F Accuracy ± 2 % F.S. + 1 digit ± 0.8 C / ± 1.5 F Function Conductivity ( µs, ms ) TDS ( Total Dissolved Solids, PPM ) Temperature ( C, F) Accessories Code Article Spare electrode plastic/gel type BNC-plug ph buffer set 4.00/7.00/10.00 (25 C) ph buffer, 4.00 (25 C), 90 ml ph buffer, 7.00 (25 C), 90 ml ph buffer, (25 C), 90 ml ph buffer 4.00 (25 C) 1 litre ph buffer 7.00 (25 C) 1 litre ph buffer (25 C) 1 litre Redox electrode plastic/gel type BNC-plug Redox calibration solution, 470 mv, 100 ml Conductivity probe (Con / TDS) (approx. 1.2 m cable) Calibration solution 1413 µs/cm Oxygen sensor, (approx. 4 m cable) Spare membrane for oxygen sensor Spare electrolyte for oxygen sensor Delivery Content Order code: SensoDirect 150 Set ph/con/tds/oxi instrument, batteries, ph electrode, temperature probe, conductivity probe, oxygen sensor, ph buffer set 4.00 / 7.00, electrolyte, membrane heads, instruction manual, warranty information, in case Order code: SensoDirect 150 Set ph / Con / TDS instrument, batteries, ph electrode, temperature probe, conductivity probe, ph buffer set 4.00 / 7.00, instruction manual, warranty information, in case Order code: SensoDirect 150 Set ph / Oxi instrument, batteries, ph electrode, temperature probe, oxygen sensor, ph buffer set 4.00 / 7.00, electrolyte, membrane heads, instruction manual, warranty information, in case Order code: SensoDirect 150 Set ph / Redox instrument, batteries, ph electrode, temperature probe, redox electrode, ph buffer set 4.00 / 7.00, instruction manual, warranty information, in case electrochemistry Range Dissolved Oxygen 0 to 20.0 mg/l (liter) Oxygen in Air 0 to % Temperature 0 to 50 C Resolution Dissolved Oxygen 0.1 mg/l 0.1 % O 2 Temperature 0.1 C Accuracy Dissolved Oxygen ± 0.4 mg/l (23± 5 C) Oxygen in Air ± 0.7% O 2 Temperature ± 0.8 C / 1.5 F Salinity 0 to 39 % Salt Correction Air Pressure 0 to 8900 meter Compensation Temperature probe PT1000 (approx. 1.5 m cable) RS232 cable for connection to a PC USB cable for connection to a PC Power supply Case incl. foam Data Retrieve Software Software which enables the user to transmit data stored on the instrument to a computer Data Logger / Acquisition Software Software which enables the user to monitor and log data on a computer (online measurement) Highlights ph/redox Conductivity/TDS Dissolved Oxygen Temperature C/ F Real time data logger Protective casing RS 232 / USB 63 Pool & Spa Water Testing - January 2015

64 Turbidity Measurement Photo: Schwimmbad & Sauna, The term "turbidity is used to describe the cloudiness or milkiness of water. In physical terms, turbidity is due to particles of varying sizes scattering or absorbing light, giving the water in question a cloudy appearance. This turbidity is caused by suspended particles such as sludge, limestone, yeast or microorganisms. The phenomenon of turbidity is measured using optoelectronic meters. An artificial light source emits a known intensity of light through a sample. The suspended particles scatter or absorb the light. The scattered light is then recorded on a photodetector. Scattered light is generally measured at an angle of 90. This measurement principle is known as nephelometry. The results are expressed in terms of FNU (Formazin Nephelometric Units) - identical with NTU (Nephelometric Turbidity Units) and TE/F (Turbidity Units Formazin) Pool & Spa Water Testing - January 2015

65 with infrared light source (EN ISO 7027) The compact Lovibond infrared turbimeter TB 210 IR is designed to allow fast, precise onsite testing. The unit measures the scattered light at an angle of 90, as stipulated in EN ISO The wide measuring range from TE/F = NTU = FNU makes the instrument suitable for various applications, ranging from drinking water to waste water. As infrared light is used for measurement purposes, the unit can be used to test both coloured and colourless liquids. Technical data Measurement cycle Display Optics approx. 8 seconds backlit LCD (on keypress) LED (λ = 860 nm) and photosensor amplifier in water proof sample chamber, infrared light Accessories Turbidity standard set T-CAL (< 0.1, 20, 200, 800 NTU) Order code: Set of 12 empty sample vials, 24 mm ø Order code: Keypad polycarbonate membrane, splash proof Power supply 9 V power pack battery Auto - OFF automatic switch-off Storage internal ring memory for 16 data sets Additional feature real time clock and date Range (Auto-range) 0, NTU Resolution NTU = 0.01 NTU NTU = 0.1 NTU NTU = 1 NTU Accuracy Housing Dimensions (L x W x H) Weight (base unit) ± 2,5 % of reading or ± 0.01 NTU (0-500 NTU) ± 5 % ( NTU) ABS 190 x 110 x 55 mm approx. 0.4 kg Ambient Temperature: 0 40 C conditions rel. humidity: 30 90% Delivery content TB 210 IR in a sturdy plastic case 4 turbidity standards (< 0.1, 20, 200 and 800 NTU) Battery 3 vials (ø 24 mm) with lids Reference instrument Approval Software based user calibration using T-CAL-Standards (see accessories) CE Warranty information Certificate of Compliance Instruction manual Order code Pool & Spa Water Testing - January 2015

66 Pool Software Highlights Analyses water balance Set parameter boundaries specific to your customer Customizable for up to 9,999 customers, 99 pools per customer Recommends chemical dosing Suitable for domestic and public pools Can be used independently of PM 600/620 with manual readings The Lovibond pool software is an ideal tool for commercial pool operators to measure pool parameters, analyse the results and propose the recommended treatments. Customizable for up to 9,999 customers and 99 pools per customer, the pool software provides a self-contained unit for operators on-the-road. Photo: Elsebad, Schwerte, Designed to enhance the functionality of the Lovibond PM 600/620 photometers, the pool software analyses all the essential pool parameters required for Balanced Water. Once the analysis has been made, the software then automatically tries to restore the water s balance; recommending the required chemical dosing to bring the water as close as possible to zero on the Langelier Saturation Index. Operators can rest assured their customers are accurately informed and the right amount of chemicals are administered. Order code: Pool & Spa Water Testing - January 2015

67 The pool software can either be used as an integrated software tool with the Lovibond PM photometers or as a stand-alone application to analyse the Balanced Water parameters of swimming pools. Designed originally to enhance the functionality of the PM photometerss, AquaMATE downloads the measured parameter information via an infrared modem, stores the data to a PC and builds a series of tests which are then allocated to a specific swimming pool of a particular customer. This data, together with the swimming pool configuration data, can then be used to interpret the water quality and analyse which parameter corrections are required and what chemical dosing is recommended. When used independently of the PM photometers, the operator can either enter the values via the built-in tools or manually enter the measurement results. The pool software has been designed as a modular application so multi user interfaces may be displayed on screen at any one time by selecting the icons as depicted below: General configuration The General Configuration Module enables the user to: Select the User Interface language: English, German, French, Italian, Spanish. Enter customer data as it should appear on the header of printed documents. Preview capability is available. Set the parameter boundaries for Chlorine and Bromine treated swimming pools respectively per category. The categories are: Private Pools Residential Pools Hotels, Schools, Camps, Vacation Resort Pools Public Pools The parameter boundaries for selection are: Free or Available Chlorine, Combined Chlorine, Total Bromine, ph and Cyanuric Acid. Customer file In the Customer File, the user can store, modify or delete Customer and Pool data. It can contain up to 9,999 customers and 99 pools per customer. Product configuration The Product configuration module allows the user to add and remove chemical products that might be required to correct the water balance. These are acids and bases needed to lower or raise the ph and/or Total Alkalinity, chemicals used to raise the Calcium Hardness and Cyanuric Acid required for protecting chlorine from UV depletion. Data transfer from photometer This module allows the user to import test data from the PM photometers to the PC. If a Photometer is not available or additional test results have to be added (such as Temperature or TDS), it is possible to do this manually. Water balance The Water Balance module enables the user to interpret the pool water quality through a given set of parameters and modify a certain number of water parameters in manual or automatic mode. In manual mode, after setting the start parameters, the user can raise or lower the ph or Total Alkalinity (TA), the Calcium Hardness (CH) and/ or increase the Cyanuric Acid (CA) concentration. Scrollbars and textboxes can be used to alter parameter values. Provided that all necessary parameter values are available, the Langelier Saturation Index (SI) is calculated continuously when changes in one of the values occur. In automatic mode, the software tries to restore the water balance by trying to equalise the SI to zero or a value as close as possible to zero. It takes into account the parameter boundaries set in the General Configuration module and the possible choice of products (chemicals) and their availability. Once the start parameters have been set, clicking on the Restore water balance button opens a new window with dosage instructions or information about the failure to improve the water balance. Handy tools Chlorine dosage Enables the user to calculate the amount of a selected Chlorine donor needed to raise the free or available free Chlorine concentration to the desired level. Acid demand Enables the user to calculate the quantity of acid needed to reduce the ph of the pool water to a certain value using the commonly named acid demand method. phosphate removal Calculates the quantity of Phosphate remover (Lanthanum compounds) needed to either reach zero Phosphate or the desired low level. Salt chlorination Analyses the amount of salt to be added to the pool water in order to restore the ideal concentration of salt according to the salt chlorination equipment producer s specifications. System requirements Processor RAM minimum: 4 MHz, recommended: 1 GHz minimum: 96 MB, recommended: 512 MB Screen resolution minimum: 1024 x 768, (screen depending) Operating system Windows XP, Windows Vista, Windows 7 Disc space approx. 10 MB The software has been developed using the.net framework 2.0 that primarily runs on Microsoft Windows platforms. It may be necessary to update the application soon in order to make it fully compatible with Windows Vista and Windows 7, using.net framework 3.5 or 4.0. The.NET Framework Client Profile is not supported on IA-64-based (Itanium) Windows is a registered Trademark of Microsoft Corporation 67 Pool & Spa Water Testing - January 2015

68 Environmental Water Analysis Lovibond General Catalogue The general catalogue includes detailed information on topics relating to water analysis.national and international standards and regulations are also covered. General Catalogue, order code: Visit the download area on our website at to obtain a copy of the catalogue Pool & Spa Water Testing - January 2015