Discipline Chemical Testing Issue Date Certificate Number T-0264 Valid Until Last Amended on - Page 1 of 6

Size: px
Start display at page:

Download "Discipline Chemical Testing Issue Date Certificate Number T-0264 Valid Until Last Amended on - Page 1 of 6"

Transcription

1 Last Amended on - Page 1 of 6 I. PLASTICS AND RESINS 1. Low Density polyethylene Film (black) HDPE Material for moulding & Extrusion HDPE Pipes for potable water supplies RotoMoulded PE Water Storage Tanks PE Pipes for Irrigation Laterals Irrigation System Pipe Irrigation System Coupler HDPE Pipe for Sewerage Polyethylene Microtubes for Micro irrigation, PE/Al/PE composite pressure pipes for hot and cold water supplies, Textiles-Laminated HDPE Fabric (Geo membrane) for Water proof lining, Plastic Material/Product Carbon black content IS 2530: 1963 Cl 10.1 IS 7328: 1974 Cl ASTM D % to 75 %

2 Last Amended on - Page 2 of 6 2. Low Density polyethylene Film (black), HDPE Pipe for Sewerage Polyethylene Microtubes for Micro irrigation, PE/Al/PE composite pressure pipes for hot and cold water supplies, Textiles-Laminated HDPE Fabric (Geo membrane) for Water proof lining, Plastic Material/Product 3. HDPE Pipes for potable water supplies, RotoMoulded PE Water Storage Tanks, PPR Pipes for hot and cold supplies, Containers for packing of natural mineral water, PE/Al/PE composite pressure pipes for hot and cold water supplies, Polyethylene Flexible pouches for the packing of natural mineral water and packaged drinking water Carbon Black Dispersion IS 2530: 1963 Cl. 16 ASTM D Overall migration test IS 9845: 1986 Cl IS 9833: mg /L to 70mg/L

3 Last Amended on - Page 3 of 6 4. Polyamide multifilament ropes Tarpaulin made from High Density Woven Fabric Poly ethylene ropes Textiles High strength polyolefin's copolymer ropes Poly propylene ropes Melting point ASTM D 3418 Room Temperature to 400 C 5. PVC & its copolymer Resin 6. UPVC Pipes for potable water supplies UPVC Injection Moulded Fittings for SWR K-value IS 4669: 1968 Cl & 8 ASTM D Sulphated Ash Content IS 4985: 2000 Cl Annex -B 50 to % to 75 % 7. High Density Polyethylene (HDPE)/ Polypropylene (PP) Woven Sacks For Packing 50 Kg/25 Kg Food grains 8. UPVC Injection Moulded Fittings for SWR Unplasticized Polyvinyl Chloride (PVC-U) Pipes for soil and waste discharge systems inside buildings including ventilation and rainwater system Ash Content IS 14887: % to 50 % Resistance to sulphuric acid IS (Part 7): 1986 Cl % to 15 %

4 Last Amended on - Page 4 of 6 9. PE Pipes for Irrigation Laterals Irrigation Equipments - Emitters Irrigation System - Pipe Irrigation System - Coupler HDPE Pipe for Sewerage Polyethylene Microtubes for Micro irrigation HDPE woven beds for vermiculture Susceptibility to environmental stress cracking IS 12786: 1989 Annexure D ASTM D Agro Textiles HDPE laminated woven Lay Flat Tube for Irrigation Environmental stress cracking test IS 16190: 2014 Annexure D 11. Containers for packing of natural mineral water Polyethylene Flexible pouches for the packing of natural mineral water and packaged drinking water Water Potability Test IS 15410: 2003 IS 15609: CPVC pipes for hot & cold water supplies Chlorine Content IS 15778: % to 70 %

5 Last Amended on - Page 5 of PVC Geo membranes for lining Unsaturated Polyester Resin System Volatile loss / Volatile content IS 15909: 2010 IS 6476: % to 75 % 14. PVC Geo membranes for lining Water extraction IS 15909: % to 50 % 15. Glass fibre rovings for the reinforcement of polyester and of epoxide resin system Moisture Content/ Hygroscopicity IS 11320: 1997 IS 4308: % to 50 % 16. Unsaturated Polyester Resin System Solvent cement for use with unplasticized polyvinylchloride plastic pipe and fittings Viscosity IS 6476: 1994 IS 14182: 1994

6 Last Amended on - Page 6 of Structured-Wall Plastics Piping Systems for Non- Pressure Drainage and Sewerage Pipes and Fittings with Non-Smooth External Surface, Type B Unplasticized Polyvinyl Chloride (PVC-U) pipes for soil and waste discharge systems inside buildings Resistance to Dichloromethane IS (Part 11) IS 13592: mg/l to 70mg/L 18. UPVC Injection Moulded Fittings for SWR Unplasticized Non- Pressure Polyvinyl Chloride (PVC -U) Pipes for use in Underground Drainage and Sewerage Systems- (CED 50: Plastic Piping System) TiO 2 Content IS 14735: 1999 as per annexure A 0.5 % to 15 % -X-X-X-X-X-X-X-X-X-X-X-X-X-X- NOTE: The has demonstrated competence for the stated scope for WATER. This however does not fully cover the specification requirements of BIS for the Packaged Drinking Water as per IS and the Packaged Natural Mineral Water IS 13428