Sub: - An application for obtaining Environment Clearance for New Unit.

Size: px
Start display at page:

Download "Sub: - An application for obtaining Environment Clearance for New Unit."

Transcription

1 Brief Note: Sub: - An application for obtaining Environment Clearance for New Unit. We M/s. Nemi Chem Industries Unit-2 are planning to manufacturing activity following products at Plot 1, Survey 316, Opp. Dharti Industrial Estate, Besides Virat Industrial Estate, Village-Dhanot, Taluka-Kalol, Gandhinagar. NAME OF PRODUCTS Product Name Group1. Intermediates 1. K-Acid 2. SPCP 3. Sulpho V.S 4. N.W Acid 5. PAPSA Group 2. Dyes (Alternative Production) 1. Reactive Dyes 1. Reactive Black 8/HN 2. Reactive Orange 12/ Reactive Golden Yellow HR 3. Reactive Orange 13/ H2R 4. Reactive Yellow 18/H4G 5. Reactive Blue 194/ Reactive Navy Blue ME2GL 6. Reactive Red 195/ME4BL 7. Reactive Yellow 145/MERL 8. Reactive Yellow 160/ME4GL 9. Reactive Black 5/B 10. Reactive Red 198/RB 11. Reactive Yellow 15/ Reactive Violet 5R 12. Reactive Yellow 42/ FG 13. Reactive Black WNN Quantity (MT/Month)

2 2. Direct Dyes 1. Direct Black 22/ VSF 2. Direct Red 31/ 12B 3. Direct Orange Direct Yellow Direct Yellow 11/ Paper Yellow R 6. Direct Violet 9/ BRILL Violet B 7. Direct Blue 86/ Turquoise blue GL 8. Direct Blue 1/ FF 3. Acid Dyes 1. Acid Black 1/ 10 BX 2. Acid Blue 193/ Blue MTR 3. Acid Brown75/CR 4. Acid Red 119/ Maroon Crude 4. Solvent Dyes: 1. Solvent Blue Solvent Red Solvent Yellow Solvent Green 3 5. Food Colors: 1. Tartrazin 2. Sunset Yellow 3. Chocolate Brown 4. Ponceau 4R 1. Reactive Turquoise Blue 21/G 2. Reactive Orange 122/ ME2RL 3. Acid Violet 90/ Bordeaux MB 4. Acid Black 210/NT 75 Based on the Proposed Products and location of our Project Site, our project is fall under Activity 5 (f) & category A. So, as per the MOEF notification dated 14 th September 2006 & its amendment letter, we have to apply for obtaining Environment Clearance.

3 Details of Water Consumption & Wastewater generation Application Water Consumption (KL/Day) Waste water generation (KL/Day) Domestic 5 4 Gardening 0 Industrial Process Washing Boiler 50 5 Cooling 50 5 Scrubber Total

4 Details of Effluent Treatment Plant Name of Unit Quantity Nos. Capacity 1. Collection Tank 2 50 (Each) 2. Neutralization Tank 2 50 (Each) 3. Hoper Bottom Settling Tank Sludge Drying Bed Final Collection Tank 1 100

5 Details of Flue Gas Emission Details of Flue Gas Emission And Process Gas emission system with APC System Stack attached To Steam Boiler 1 (For Group1) Steam Boiler 2 (For Group2) Hot Air Generator (10 lacs Kcal) Stack Height In Meter APC System Multi Cyclone Dust collector Followed By Bag Filter Multi Cyclone Dust collector Followed By Bag Filter Multi Cyclone Dust collector Followed By Bag Filter 4. DG Set Pollutants SPM SO 2 mg/nm 3 ppm < 150 < 100 mg/nm 3 ppm < 150 mg/nm 3 < 100 ppm < 150 mg/nm 3 < 100 ppm < 150 < 100 mg/nm 3 ppm NOX ppm Details of Process Emission Stack attached To APCD System Stack Height Pollutants 1 Reaction vessel Two Stage Scrubber system 11 m HCl <= 20 Cl2 <= 09 2 Reaction vessel Two Stage Scrubber system 11 m NH3 <= Reaction vessel Two Stage Scrubber system 11 m SO2 <= 40 4 Reaction vessel Scrubber system 11 m HCl <= 20 5 Reaction vessel Scrubber system 11 m SO2 <= 40

6 6 Spray dryer Wet scrubber 11 m SPM <= 150 Fuel Requirement Stack attached To Steam Boiler - 1 Steam Boiler - 2 Hot Air Generator - 1 (10 lacs Kcal) DG Set Stack Height In Meter Type of Fuel Coal/ lignite/ wood/ agro waste/ Coal/ lignite/ wood/ agro waste/ Coal/ lignite/ wood/ agro waste/ Quantity 7 MT/Day 7 MT/Day 4.8 MT/Day APC System Multi Cyclone Dust collector Followed By Bag Filter Multi Cyclone Dust collector Followed By Bag Filter Multi Cyclone Dust collector Followed By Bag Filter 11 Diesel 20 Liter/hr. ---

7 DETAILS OF HAZARDOUS WASTE GENERATION WITH ITS MANAGEMENT Details of Hazardous waste generation with its management No Type of Hazardous Waste Cat. Quantity Management 1. ETP Sludge MT/Year Collection, Storage, Transportation, Disposal to TSDF site 2. Iron Sludge MT/Year Collection, Storage, Transportation, Disposal to TSDF site or Actual recycler. 3. Discarded Bags/Containers/Drums Nos./Year Used for packing of ETP waste or return back to supplier. 4. Used Oil Liter/Year Storage into carboys and ultimately Reuse or sell to registered re refiners