Responsible Editor: Daikin Europe N.V., Zandvoordestraat 300, B-8400 Oostende

Size: px
Start display at page:

Download "Responsible Editor: Daikin Europe N.V., Zandvoordestraat 300, B-8400 Oostende"

Transcription

1 Air Conditioners Technical Data Technical Data O u t d o o r u n i t - P a i r a p p l i c a t i o n T E C H N I C A L DATA - O U T D O O R U N I T - PA I R A P P L I C AT I O N O u t d o o r u n i t - P a i r a p p l i c a t i o n Daikin s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has led to its close involvement in environmental issues. For several years Daikin has had the intention to become a leader in the provision of products that have limited impact on the environment. This challenge demands the eco design and development of a wide range of products and an energy management system, resulting in energy conservation and a reduction of waste. The present leaflet is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of this leaflet to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of this leaflet. All content is copyrighted by Daikin Europe N.V. Please fill out the requested information Please fill out the requested information Daikin Europe N.V. participates in the Eurovent Certification Programme for Air Conditioners (AC), Liquid Chilling Packages (LCP) and Fan Coil Units (FC); the certified data of certified models are listed in the Eurovent Directory. Multi units are Eurovent certified for combinations up to 2 indoor units. Daikin products are distributed by: Naamloze Vennootschap - Zandvoordestraat 00, B-8400 Oostende - Belgium BE RPR Oostende EEDEN-00 0/ Copyright Daikin Printed on non-chlorinated paper. Prepared by Goekint Graphics NV, Belgium Responsible Editor: Daikin Europe N.V., Zandvoordestraat 00, B-8400 Oostende E E D E N RXG-K E E D E N - 0 0

2 TABLE OF CONTENTS RXG-K Features Specifications Nominal Capacity And Nominal Input Nominal Capacity And Nominal Input Nominal Capacity And Nominal Input Technical Specifications Electrical Specifications Electrical data Electrical Data Options Options Capacity tables Cooling/Heating Capacity Tables Dimensional drawings Dimensional Drawings Centre of gravity Centre of Gravity Piping diagrams Piping Diagrams Wiring diagrams Wiring Diagrams - Single Phase Sound data Sound Pressure Spectrum Operation range Operation Range Split - Sky Air Outdoor Unit

3 k i ni l p- pr ao t o i dr - l ti pau Features c S U K G X PS O R Energy efficient units: full range A class energy labels Energy saving during standby mode: reduces current consumption by about 80% when operating In standby. If no people are detected for more than 20 minutes, the system will automatically switch to the current-saving mode. Outdoor unit silent operation: "silent" button on the remote control lowers the operation sound of the outdoor unit by dba to ensure a quiet environment for the neighbourhood. Outdoor units for pair application Outdoor units are fitted with a swing compressor, renowned for its low noise and high energy efficiency Daikin outdoor units are neat, sturdy and can easily be mounted on a roof or terrace or simply placed against an outside wall optional 2 Split - Sky Air Outdoor Unit

4 2 Specifications 2- Nominal Capacity And Nominal Input FTXG25JVBS / RXG25K2VB FTXG5JVBS / RXG5K2VB FTXG50JVBS / RXG50K2VB Cooling capacity Min. kw..4.7 Btu/h 4,400 4,800 5,800 kcal/h,20,200,460 Nom. kw 2.5 ().5 () 5.0 () Btu/h 8,500 (),900 () 7,00 () kcal/h 2,50 (),00 () 4,00 () Max. kw Btu/h 0,200,000 8,00 kcal/h 2,580,270 4,560.0 Heating Min. kw..4.7 capacity Btu/h 4,400 4,800 5,800 kcal/h,20,200,460 Nom. kw.4 (4) 4.0 (4) 5.8 (4) Btu/h,600 (4),600 (4) 9,800 (4) kcal/h 2,920 (4),440 (4) 4,990 (4) Max. kw Btu/h 5,400 7,00 22,200 kcal/h,870 4,00 5,590 Power input Cooling Min. kw Nom. kw Max. kw Heating Min. kw Nom. kw Max. kw EER COP Annual energy consumption kwh Energy label Cooling A A A Heating A A A Piping Liquid OD mm connections Gas OD mm Drain OD mm Heat insulation Both liquid and gas pipes Notes () Energy label: scale from A (most efficient) to G (less efficient) (2) Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) () Cooling: indoor temp. 27ºCDB, 9.0ºCWB; outdoor temp. 5ºCDB, 24ºCWB; equivalent piping length: 5m (4) Heating: indoor temp. 2ºCDB; outdoor temp. 7ºCDB, 6ºCWB; piping length: 5m (5) When connected with multi-system outdoor unit, refer to the specifications of the multi outdoor unit to be connected Nominal Capacity And Nominal Input FTXG25JVBW / RXG25K2VB FTXG5JVBW / RXG5K2VB FTXG50JVBW / RXG50K2VB Cooling Min. kw..4.7 capacity Btu/h 4,400 4,800 5,800 kcal/h,20,200,460 Nom. kw 2.5 ().5 () 5.0 () Btu/h 8,500 (),900 () 7,00 () kcal/h 2,50 (),00 () 4,00 () Max. kw Btu/h 0,200,000 8,00 kcal/h 2,580,270 4,560.0 Split - Sky Air Outdoor Unit

5 2 Specifications Nominal Capacity And Nominal Input FTXG25JVBW / RXG25K2VB FTXG5JVBW / RXG5K2VB FTXG50JVBW / RXG50K2VB Heating Min. kw..4.7 capacity Btu/h 4,400 4,800 5,800 kcal/h,20,200,460 Nom. kw.4 (4) 4.0 (4) 5.8 (4) Btu/h,600 (4),600 (4) 9,800 (4) kcal/h 2,920 (4),440 (4) 4,990 (4) Max. kw Btu/h 5,400 7,00 22,200 kcal/h,870 4,00 5,590 Power input Cooling Min. kw Nom. kw Max. kw Heating Min. kw Nom. kw Max. kw EER COP Annual energy consumption kwh Energy label Cooling A A A Heating A A A Piping Liquid OD mm connections Gas OD mm Drain OD mm Heat insulation Both liquid and gas pipes Notes () Energy label: scale from A (most efficient) to G (less efficient) (2) Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) () Cooling: indoor temp. 27ºCDB, 9.0ºCWB; outdoor temp. 5ºCDB, 24ºCWB; equivalent piping length: 5m (4) Heating: indoor temp. 2ºCDB; outdoor temp. 7ºCDB, 6ºCWB; piping length: 5m (5) When connected with multi-system outdoor unit, refer to the specifications of the multi outdoor unit to be connected. 2- Nominal Capacity And Nominal Input FVXG25K2VB / RXG25K2VB FVXG5K2VB / RXG5K2VB FVXG50K2VB / RXG50K2VB Cooling Min. kw..4.7 capacity Btu/h 4,400 4,800 5,800 kcal/h,20,200,460 Nom. kw 2.5 ().5 () 5.0 () Btu/h 8,500 (),900 () 7,00 () kcal/h 2,50 (),00 () 4,00 () Max. kw Btu/h 0,200,000 9,00 kcal/h 2,580,270 4,820 Heating Min. kw..4.7 capacity Btu/h 4,400 4,800 5,800 kcal/h,20,200,460 Nom. kw.4 (4) 4.5 (4) 5.8 (4) Btu/h,600 (4) 5,400 (4) 9,800 (4) kcal/h 2,920 (4),870 (4) 4,990 (4) Max. kw Btu/h 5,400 7,00 27,600 kcal/h,870 4,00 6,970 Power input Cooling Min. kw Nom. kw Max. kw Heating Min. kw Nom. kw Max. kw EER Split - Sky Air Outdoor Unit

6 2 Specifications 2- Nominal Capacity And Nominal Input FVXG25K2VB / RXG25K2VB FVXG5K2VB / RXG5K2VB FVXG50K2VB / RXG50K2VB COP Annual energy consumption kwh Energy label Cooling A Heating A Piping Liquid OD mm 6.5 connections Gas OD mm Drain OD mm 8 Heat insulation Both liquid and gas pipes Notes () Energy label: scale from A (most efficient) to G (less efficient) (2) Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) () Cooling: indoor temp. 27ºCDB, 9ºCWB; outdoor temp. 5ºCDB, 24ºCWB (4) Heating: indoor temp. 20ºCDB; outdoor temp. 7ºCDB, 6ºCWB (5) When connected with multi-system outdoor unit, refer to the specifications of the multi outdoor unit to be connected Technical Specifications RXG25K2VB RXG5K2VB RXG50K2VB Casing Colour Ivory white Dimensions Unit Height mm Width mm Depth mm Packed unit Height mm Width mm Depth mm Weight Unit kg 4 48 Packed unit kg 8 5 Packing Weight kg 4 5 Heat Length mm exchanger Rows Quantity 2 Fin pitch mm.4.8 Stages Quantity 24 2 Tube type ø7 Hi-XA ø8 Hi-XA Fin Type WF fin Treatment Corrosion resistant Fan Type Propeller fan Air flow rate Cooling High m³/ min cfm,8,27,797 Super low m³/ min cfm,06,726 Heating High m³/ min cfm 999,589 Super low m³/ min cfm 904,52 Fan motor Model ARS640DA KFD C Output W 2 5 Speed Cooling High rpm Super low rpm Heating High rpm Super low rpm Sound power Cooling High dba 6 6 level Sound Cooling High dba pressure level Silent operation dba 4 44 Heating High dba Silent operation dba Split - Sky Air Outdoor Unit 5

7 2 Specifications Technical Specifications RXG25K2VB RXG5K2VB RXG50K2VB Compressor Model YC2AEXD 2YC6BXD Type Hermetically sealed swing compressor Output W 600,00 Operation Cooling Ambient Min. ºCDB -0 range Max. ºCDB 46 Heating Ambient Min. ºCWB -5 Max. ºCWB 20 Refrigerant Type R-40A Charge kg.05.6 Refrigerant oil Type FVC50K Charged volume l Piping Drain ID mm - connections Piping length OU - IU Max. m 20 0 System Chargeless m 0 Level difference IU - OU Max. m Electrical Specifications RXG25K2VB RXG5K2VB RXG50K2VB Power supply Phase ~ Frequency Hz 50 Voltage V Current Nominal Cooling A 2.90 () 2.8 (2) 2.7 () 4.69 () 4.50 (2) 4.0 () 6.9 () 6.54 (2) 6.5 () running current (RLA) Heating A.99 ().79 (2).60 () 5.88 () 5.58 (2) 5.9 () 7.2 () 6.8 (2) 6.5 () Starting Cooling A current Heating A Notes () 220V (2) 20V () 240V (4) Operation range in combination with Nexura, FVXG-K: min. 0ºCDB ~ max. 46ºCDB 6 Split - Sky Air Outdoor Unit

8 Electrical data - Electrical Data Split - Sky Air Outdoor Unit 7

9 Electrical data - Electrical Data 8 Split - Sky Air Outdoor Unit

10 4 Options 4 - Options 4 Split - Sky Air Outdoor Unit 9

11 5 Capacity tables 5 - Cooling/Heating Capacity Tables 5 0 Split - Sky Air Outdoor Unit

12 5 Capacity tables 5 - Cooling/Heating Capacity Tables 5 Split - Sky Air Outdoor Unit

13 5 Capacity tables 5 - Cooling/Heating Capacity Tables 5 2 Split - Sky Air Outdoor Unit

14 5 Capacity tables 5 - Cooling/Heating Capacity Tables 5 Split - Sky Air Outdoor Unit

15 5 Capacity tables 5 - Cooling/Heating Capacity Tables 5 4 Split - Sky Air Outdoor Unit

16 5 Capacity tables 5 - Cooling/Heating Capacity Tables 5 Split - Sky Air Outdoor Unit 5

17 6 Dimensional drawings 6 - Dimensional Drawings 6 6 Split - Sky Air Outdoor Unit

18 7 Centre of gravity 7 - Centre of Gravity 7 Split - Sky Air Outdoor Unit 7

19 8 Piping diagrams 8 - Piping Diagrams 8 8 Split - Sky Air Outdoor Unit

20 9 Wiring diagrams 9 - Wiring Diagrams - Single Phase 9 Split - Sky Air Outdoor Unit 9

21 0 Sound data 0 - Sound Pressure Spectrum 0 20 Split - Sky Air Outdoor Unit

22 0 Sound data 0 - Sound Pressure Spectrum 0 Split - Sky Air Outdoor Unit 2

23 Operation range - Operation Range 22 Split - Sky Air Outdoor Unit