1 Available online at ScienceDirect Procedia Engineering 199 (2017) X International Conference on Structural Dynamics, EURODYN 2017 Installation and results from the first 6 months of operation of the dynamic monitoring system of Baixo Sabor arch dam Sérgio Pereira a, Filipe Magalhães a, *, Jorge Gomes b, Álvaro Cunha a, José V. Lemos b a Construct-ViBest, Faculty of Engineering (FEUP), University of Porto, Rua Dr. Roberto Frias, Porto, Portugal b National Laboratory of Civil Engineering (LNEC), Av. do Brasil 101, Lisboa, Portugal Abstract The Baixo Sabor hydroelectric power plant, located in the northeast of Portugal, includes a reservoir with a storage capacity of 630 million m 3 of water created by a concrete double-curvature arch dam, 123 m high, which was equipped with a 20-channel vibration based structural health monitoring system. This paper, apart from describing the dam, presents the main characteristics of the monitoring system and the results obtained during the first 6 months of operation and the first filling of the reservoir. These results include in particular the characterization of the accelerations amplitude and the evolution of the dam modal parameters (natural frequencies, modal damping ratios and mode shapes). It is particular interesting to observe the influence of the water level on the modal parameters and the development of statistical models to mitigate this effect The Authors. Published by Elsevier Ltd. Peer-review under responsibility of the organizing committee of EURODYN Keywords: arch dam; monitoring; operational modal analysis 1. Introduction The Baixo Sabor hydroelectric power plant is located in the northeast of Portugal. Its reservoir extends 60 km north along the Sabor river, a tributary of the Douro River, allowing a useful storage of 630 million m3 of water [1]. This is a strategic location, since there are four other power plants located downstream that can be supplied by Baixo Sabor * Corresponding author. Tel.: ; fax: address: author@institute.xxx The Authors. Published by Elsevier Ltd. Peer-review under responsibility of the organizing committee of EURODYN /j.proeng
2 Sérgio Pereira et al. / Procedia Engineering 199 (2017) reservoir in case of need. The concrete double-curvature arch dam, embedded in a narrow valley zone, is 123 m high and its crest 505 m long. The arch is composed by 32 blocks, separated by vertical contraction joints, and includes six horizontal visit galleries. Figure 1 shows an aerial picture of the dam and the reservoir, referring to May 2016, after the monitoring had started. Figure 1 Baixo Sabor arch dam [1]. The continuous dynamic monitoring of Baixo Sabor dam is being carried out by ViBest/FEUP and LNEC, in order to identify the dam s dynamic characteristics and their evolution over time, taking into account the variation of ambient and operational conditions, as well as the possible evolution of the materials mechanical properties. Similar works have been performed in the past, as for instance in Mauvoisin dam in Switzerland [2] or Cabril dam in Portugal [3]. This paper describes the dynamic monitoring system installed in the Baixo Sabor upstream step dam and presents the results obtained during the first six months of operation of the referred monitoring system, between 01/12/2015 and 31/05/2016, which comprehend a major part of the reservoir-filling period. Results from the application of automated operational modal analysis are presented and the use of regression models for the elimination of operational effects on the estimated natural frequencies, such as the water level, is explored. 2. Description of the Monitoring System To ensure a good characterization of the dynamic behavior of the dam, 20 uniaxial accelerometers were radially installed along the three upper galleries. Figure 2 characterizes the position of the accelerometers, marked in red. In the GV1 gallery, 12 accelerometers are divided in two groups of six, disposed on each side of the spillway. Each of these groups of six is connected to a digitizer, which is linked to a field computer. In turn, the eight accelerometers on the two lower galleries are connected to a different set of two digitizers. All the equipment is connected by optic fibre and the synchronization of the data recorded by each digitizer is assured with GPS antennas. The main field computer is connected to the fiber optic network between the dam and the plant, thus allowing remote access. All the installed accelerometers are uniaxial and force balance, which were configured to measure in the range g and 0.25 g, in order to allow the accurate characterization of very low acceleration signals. The dynamic monitoring system is configured to continuously record acceleration time series with a sampling rate of 50 Hz and a duration of 30 minutes at all instrumented points, thus producing 48 groups of time series per day. Figure 2 Position of measuring points on Baixo Sabor monitoring system [4].
3 2168 Sérgio Pereira et al. / Procedia Engineering 199 (2017) Data Processing The continuously collected data is independently processed by the two institutions involved in this project (ViBest/FEUP and LNEC), this paper presenting the processing developed by ViBest/FEUP. This is accomplished with a monitoring software developed at ViBest/FEUP called DynaMo, initially designed for continuous dynamic monitoring of bridges and now adapted for the monitoring of dams [5]. As already referred, the monitoring system organizes the continuously collected acceleration time series in files with 30 minutes which are regularly downloaded through an FTP connection to the main field computer. These files are then handled by DynaMo software that was configured to perform the following tasks: - backup the original data file in a database; - pre-process of the acceleration time series, which includes trend elimination, filtering with an eighth-order low-pass Butterworth filter [6] and re-sampling with a frequency of 25 Hz; - characterize the acceleration amplitude by maxima and root mean squares values (RMS); - construct colour maps in the frequency domain, which characterize the energy distribution along the analysed frequency range over time; - identify the bridge modal parameters (natural frequencies, mode shapes and modal damping ratios), based on its response under normal operation, using state of the art output only modal identification algorithms; - apply statistical tools to minimize the water level effects on the identified modal parameters; - store all the obtained results in a database; - publish the most important results on a webpage. The most important and challenging task is the continuous automated identification of the modal parameters. In the present application, after testing alternative output only algorithms [7], it was concluded that good results could be obtained combining the Covariance Driven Stochastic Subspace Identification method (SSI-COV) with a routine based on clusters analysis to automate its application. A description of this approach and of its theoretical background can be found in reference [8]. 4. Analysis of the Results 4.1. Identified Modal Parameters The six months of data were processed following the steps described in the previous section. The first six modes of vibration were identified and natural frequencies, modal damping values and modal configurations were obtained. The three-dimensional representations of the modal configurations are presented in Figure 3, in which the dashed line represents the dam s original geometry and the modal configuration is represented in red. The first, third and fifth modes are approximately symmetric and the second, fourth, and sixth are antisymmetric. Mode 1 Mode 2 Mode 3 Mode 4 Mode 5 Mode 6 Figure 3 Modal configuration of the first six modes of Baixo Sabor arch dam. Modal estimates corresponding to the first six modes are resumed in Table 1, where minimum, maximum, mean and standard deviation frequencies and damping values are presented. It is important to notice the significant difference between minimum and maximum frequencies for each vibration mode (even after the elimination of outliers), which is reflected in the standard deviation values as well, indicating significant oscillations during the evaluation period. Additionally, the damping values present slightly higher mean values for the symmetric modes.
4 Sérgio Pereira et al. / Procedia Engineering 199 (2017) Table 1 Modal Parameters Mode ffff [Min ; Max] [Hz] ffff mmmmmmmmmmmmmmmm [Hz] ffff ssssssssssss [Hz] ξξξξ [Min ; Max] [%] ξξξξ mmmmmmmmmmmmmmmm [%] ξξξξ ssssssssssss [%] Description 1 [2,43 ; 2,75] 2,53 0,10 [1,16 ; 3,16] 1,50 0,23 Symmetric 2 [2,57 ; 2,92] 2,68 0,11 [0,85 ; 2,11] 1,42 0,15 Antisymmetric 3 [3,33 ; 3,85] 3,51 0,17 [0,55 ; 3,00] 1,67 0,25 Symmetric 4 [3,92 ; 4,50] 4,12 0,19 [0,92 ; 1,82] 1,36 0,16 Antisymmetric 5 [4,78 ; 5,34] 4,99 0,18 [0,75 ; 2,66] 1,88 0,30 Symmetric 6 [5,32 ; 5,95] 5,58 0,16 [0,50 ; 2,29] 1,44 0,26 Antisymmetric However, the evolution of the modal parameters is easier to understand when graphically depicted. Therefore, the temporal evolution of the natural frequencies of the first six modes of vibration of the structure is characterized in Figure 4 a), where each point corresponds to a 12-hour average. The small blank spaces correspond to periods of system failure or maintenance, for which no data is available. As 12-hour averages were calculated, two values are presented per day. This process leads to a visually clean figure without losing accuracy in the characterization of the modal parameters fluctuations, as it will be illustrated latter. It should be taken into account that modal parameters variations are quite slow in such very massive structures. At the same time, Figure 4 b) shows the temporal evolution of the reservoir water level. Observing these two figures (Figure 4a and b), it is possible to observe that the values of the natural vibration frequencies of the structure have decreased considerably and continuously since the beginning of the monitoring. Moreover, this decrease accompanies the increase of the water level of the reservoir, thus suggesting an inverse proportionality between these two variables. This phenomenon is clearly observed during January, when intense rains occurred, motivating the sudden rise in the reservoir water level and a sudden drop in the frequency values, which would be expected, given that a large amount of mass was added to the dam-reservoir system. Furthermore, it is interesting to observe the sensitivity of the natural frequencies to the relatively low variations of the water level occurred between February and May, thus, confirming the accuracy achieved in the natural frequencies estimates. In turn, Figure 5 presents the temporal evolution of the first three modal damping ratios, with colours corresponding to those in Figure 4. In this case, it is shown that the modal damping values of modes 2 and 3 are similarly influenced by the reservoir water level, while that influence is not significant in the case of mode 1. As observed in other monitoring applications the modal damping estimates present a much higher scatter than the observed in the natural frequencies. These experimental results obtained during the first filling of a dam reservoir are quite unique and very relevant for the tuning of numerical models that take into account the influence of the water level in the dynamic behaviour of dams. Figure 4 a) Time evolution of natural frequencies 12-hour average; b) Time evolution of reservoir water level.
5 2170 Sérgio Pereira et al. / Procedia Engineering 199 (2017) Removal of the Effect of Operational Conditions Figure 5 Time evolution of damping ratios 12-hour averages. In order to detect small variations of the natural frequencies of the structure motivated by structural alterations, which may be associated with the occurrence of damages, it is important to minimize the effects of environmental and operational factors. In this application the factor that more strongly affects the natural frequencies is the water level. In this way, statistical relationships between the vibration frequencies of the structure and the water level in the reservoir were developed, as shown in Figure 6. The obtained quadratic regressions are generally of high quality, presenting values for the determination coefficient of the order of It is also important to note that there is much more data for the highest and lowest levels of water in the reservoir during the observation period compared to those in the intermediate zone of the figures due to the intense rains that took place in January, leading to a sudden rise of the water level. Figure 6 Correlation between the reservoir water level and the first two natural frequencies [9]. Afterwards, this effect was removed from the values of the frequencies directly estimated from the acceleration time series, resulting in the evolution of frequencies in the time represented in Figure 7. This shows a great stability over these six months and thus confirms the close relationship between the level of water in the reservoir and the vibration frequencies of the structure. Figure 7 - Time evolution of natural frequencies 12-hour averages after correction of reservoir water level effect
6 Sérgio Pereira et al. / Procedia Engineering 199 (2017) The future collection of additional data will certainly permit to enrich these models with the incorporation of factors with lower influence on the natural frequencies of this type of structures, as for instance the temperature. 5. Conclusions The dynamic monitoring system installed in Baixo Sabor dam was described and the main results obtained between December 2015 and May 2016 were presented. The processing of the time series of accelerations continuously recorded during this period and the good results obtained demonstrates that the dynamic monitoring system is functioning properly and able to automatically identify the modal properties under much different operating conditions. The results show a close relation between the water level in the reservoir and the values of the vibration frequencies, thus explaining the significant variations of the latter during the six months of evaluation. However, after correcting the effect of the water level, using regression models, it appears that during the period under analysis the dynamic behaviour of the dam remains quite stable. These experimental results obtained during the first filling of a dam reservoir are quite unique and very relevant for the tuning of numerical models that take into account the influence of the water level in the dynamic behaviour of dams. The next step of this work will comprise, on the one hand, the tuning of the modal parameters identification process, including the estimation of uncertainty bounds, and, on the other hand, the minimization of environmental and operating conditions effects on modal parameters, taking into account the use of new data and new variables, such as temperature. Acknowledgements This work was financially supported by: PTDC/ECM-EST/0805/ DAM_AGE - Advanced Online Dynamic Structural Health Monitoring of Concrete Dams, funded by FEDER funds through COMPETE Programa Operacional Competitividade e Internacionalização (POCI) and by national funds through FCT - Fundação para a Ciência e a Tecnologia; FCT PhD Scholarship SFRH/BD/100587/2014 provided to the first author. The authors would like also to acknowledge all the collaboration and support provided by EDP Produção. References [1] EDP (23/01/2017). Available at: [2] G. R. Darbre and J. Proulx, "Continuos ambient-vibration monitoring of the arch dam of Mauvoisin," Earthquake Engineering and Structural Dynamics, Article vol. 31, no. 2, pp , [3] S. Oliveira and M. Espada, "Long-term dynamic monitoring of arch dams. The case of Cabril dam, Portugal," 15th World Conference on Earthquake Engineering, [4] LNEC, FEUP, and Ambisig, "Upstream step dam of Baixo Sabor hydroelectric power plant. Characterization of the dam's dynamic behaviour through continuous monitoring. Installation Report." (in Portuguese), [5] Magalhães, F., Amador, S., Cunha, A. and Caetano, E., "Dynamo - software for vibration based Structural Health Monitoring", 6th Int. Conf. on Bridge Maintenance, Safety and Management, IABMAS 2012, Vila Erba, Lake Como, Italy, [6] Mathworks, "Matlab. R2016a.," ed, [7] Magalhães, F. and Cunha, A., "Explaining Operational Modal Analysis with data from ana arch bridge", Mechanical Systems and Signal Processing, Invited Tutorial Paper, Volume 25, Issue 5, pp , [8] Magalhães, F., Cunha, A. and Caetano, E. Online automatic identification of the modal parameters of a long span arch bridge, Mechanical Systems and Signal Processing, Vol.23, Issue 2, pp , [9] Vibest/FEUP, "Dynamic Monitoring System Baixo Sabor Dam. Results of May 2016." (in Portuguese), 2016.
Dynamic Assessment of the São João Bridge Structural Integrity
Available online at www.sciencedirect.com ScienceDirect Structural Integrity Procedia 00 (2017) 000 000 www.elsevier.com/locate/procedia 2 nd International Conference on Structural Integrity, ICSI 2017,
More informationImplementation of a Dynamic Monitoring System on a Wind Turbine
Proceedings of the 9th International Conference on Structural Dynamics, EURODYN 4 Porto, Portugal, June - July 4 A. Cunha, E. Caetano, P. Ribeiro, G. Müller (eds.) ISSN: -9; ISBN: 978-97-7-6-4 Implementation
More informationMonitoring of Environmental Effects on Modal Estimates of Large Structures
Monitoring of Environmental Effects on Modal Estimates of Large Structures Elsa CAETANO Associate Professor ecaetano@fe.up.pt Carlos MOUTINHO Assistant Professor moutinho@fe.up.pt Álvaro CUNHA Full Professor
More informationOptimization of a wind turbine vibration-based SHM system
8th European Workshop On Structural Health Monitoring (EWSHM 16), 5-8 July 16, Spain, Bilbao www.ndt.net/app.ewshm16 Optimization of a wind turbine vibration-based SHM system More info about this article:
More informationFatigue Assessment of a Bowstring Railway Bridge
Paper 106 Fatigue Assessment of a Bowstring Railway Bridge Civil-Comp Press, 2012 Proceedings of the Eleventh International Conference on Computational Structures Technology, B.H.V. Topping, (Editor),
More informationSTRUCTURE ASSESSMENT BY CONTINUOUS MONITORING APPLICATION TO SORRAIA RIVER BRIDGE
fib Symposium Keep Concrete Attractive, Budapest 2005 STRUCTURE ASSESSMENT BY CONTINUOUS MONITORING APPLICATION TO SORRAIA RIVER BRIDGE José Campos e Matos, Hélder Sousa, Wayne Santos de Assis, Joaquim
More informationVibration monitoring of long bridges and their expansion joints and seismic devices
MATEC Web of Conferences 24, 44 ( 215) DOI: 1.151/ matecconf/ 2152 444 C Owned by the authors, published by EDP Sciences, 215 Vibration monitoring of long bridges and their expansion joints and seismic
More informationVirtual Enterprise integration management based on a Meta-enterprise a PMBoK approach
Available online at www.sciencedirect.com ScienceDirect Procedia Computer Science00 (2017) 000 000 www.elsevier.com/locate/procedia CENTERIS - International Conference on ENTERprise Information Systems
More informationAvailable online at ScienceDirect. Physics Procedia 67 (2015 ) K Liquid Neon Energy Storage Unit
Available online at www.sciencedirect.com ScienceDirect Physics Procedia 67 (2015 ) 1193 1198 25th International Cryogenic Engineering Conference and the International Cryogenic Materials Conference in
More informationLoad Tests of a Cable-Stayed Bridge in Coimbra, Portugal
Load Tests of a Cable-Stayed Bridge in, Portugal Luís Oliveira Santos, Senior Research Officer; Xu Min, Research Officer; National Laboratory for Civil Engineering (LNEC), Lisbon, Portugal Summary Field
More informationSEISMIC RETROFIT OF RC HOLLOW-SECTION PIERS WITH SHEAR FAILURE
October 12-17, 28, Beijing, China SEISMIC RETROFIT OF RC HOLLOW-SECTION PIERS WITH SHEAR FAILURE ABSTRACT : P. Delgado 1, N. Vila-Pouca 2, A. Arêde 2, P. Rocha 1, A. Costa 3 and R. Delgado 2 1 Polytechnic
More informationIOMAC'15 OPERATIONAL MODAL ANALYSIS APPLIED TO A DYNAMIC STUDY OF A STRUCTURE
IOMAC'15 6 th International Operational Modal Analysis Conference 2015 May12-14 Gijón - Spain OPERATIONAL MODAL ANALYSIS APPLIED TO A DYNAMIC STUDY OF A STRUCTURE J. Fernández 1, L. Hermanns 2, A. Fraile
More informationSEISMIC ASSESSMENT AND STRENGTHENING OF A SLENDER ARCH DAM
SEISMIC ASSESSMENT AND STRENGTHENING OF A SLENDER ARCH DAM N. Nilipour 1 and L. Mouvet 2 ABSTRACT : 1 M.Sc. Civil Engineer, Project Manager, STUCKY Ltd, Switzerland 2 M.Sc. Civil Engineer, Head of Dams
More informationVibration monitoring of a grandstand in Dragon Stadium
Experimental Vibration Analysis for Civil Engineering Structures 503 Vibration monitoring of a grandstand in Dragon Stadium H. Marques, A. Arêde & R.M. Delgado FEUP, Porto, Portugal ABSTRACT: The present
More informationBlind Source Separation Based Dynamic Parameter Identification of a Multi-Story Moment-Resisting Frame Building under Seismic Ground Motions
Available online at www.sciencedirect.com Procedia Engineering 54 ( 2013 ) 299 307 The 2 nd International Conference on Rehabilitation and Maintenance in Civil Engineering Blind Source Separation Based
More informationH. Friedmann, P. Kraemer, C. Ebert: UnderwaterINSPECT Structural Health Monitoring of Offshore Foundations. Friedmann et al.
H. Friedmann, P. Kraemer, C. Ebert: UnderwaterINSPECT Structural Health Monitoring of Offshore Foundations 1 UnderwaterINSPECT Structural Health Monitoring of Offshore Foundations H. Friedmann, P. Kraemer,
More informationIOMAC' May Guimarães - Portugal
IOMAC'13 2013 May 13-15 Guimarães - Portugal CASE STUDY ON UPDATING NUMERICAL MODELS OF MASONRY ARCH BRIDGES Cristina Costa 1, António Arêde 2, Aníbal Costa 3 and Elsa Caetano 4 ABSTRACT This paper aims
More informationBenchmarking Driving Efficiency using Data Science Techniques applied on Large-Scale Smartphone Data (PhD Summary)
Benchmarking Driving Efficiency using Data Science Techniques applied on Large-Scale Smartphone Data (PhD Summary) The main objective of this PhD is to provide a methodological approach for driving safety
More informationFootbridge 2005 Second International Conference
DESIGN AND CONSTRUCTION METHOD OF THE NEW COIMBRA FOOTBRIDGE A. ADÃO DA FONSECA Civil Engineer AFAssociados Full Professor University of Porto Porto, Portugal Renato BASTOS Civil Engineer AFAssociados
More informationForced vibration testing of a thirteen storey concrete building
Forced vibration testing of a thirteen storey concrete building F. Shabbir, & P. Omenzetter Department of Civil and Environmental Engineering, University of Auckland, Auckland, New Zealand 2008 NZSEE Conference
More informationDamage assessment of structures based on monitoring data
Proceedings of the Tenth Pacific Conference on Earthquake Engineering Building an Earthquake-Resilient Pacific 6-8 November 2015, Sydney, Australia Damage assessment of structures based on monitoring data
More informationPressure Pulsations and Vibration Measurements in Francis Turbines with and without Freely Rotating Runner Cone Extension
Proceedings of the International Symposium on Current Research in Hydraulic Turbines CRHT VI March 14, 2016, Turbine Testing Lab, Kathmandu University, Dhulikhel, Nepal Paper no. CRHT2016-15 Pressure Pulsations
More informationOptimizing Canal Structure Operation in the Treasure Valley of Idaho
International Proceedings of Chemical, Biological and Environmental Engineering, Vol. 97 (2016) DOI: 10.7763/IPCBEE. 2016. V97. 7 Optimizing Canal Structure Operation in the Treasure Valley of Idaho Andrew
More informationScienceDirect. Numerical model of a district water distribution system in Bucharest. A.-M. Georgescu a, *, S. Perju a, S.-C. Georgescu b, A.
Available online at www.sciencedirect.com ScienceDirect Procedia Engineering 70 ( 2014 ) 707 714 12th International Conference on Computing and Control for the Water Industry, CCWI2013 Numerical model
More informationPerformance Monitoring of a Short-Span Integral-Abutment Bridge Using Wireless Sensor Technology
Performance Monitoring of a Short-Span Integral-Abutment Bridge Using Wireless Sensor Technology ABSTRACT: Michael V. Gangone, Matthew J. Whelan, Michael P. Fuchs, Kerop D. Janoyan Clarkson University,
More informationMIEL I Hydroelectric Power Plant
MIEL I Hydroelectric Power Plant The Miel I Power Plant, which is located in the municipality of Norcasia, forms part of the hydro potential in western Caldas. This region comprises the basins of the rivers
More informationSMALL SCALE EXPERIMENTAL TESTING TO VERIFY THE EFFECTIVENESS OF THE BASE ISOLATION AND TUNED MASS DAMPERS COMBINED CONTROL STRATEGY
SMALL SCALE EXPERIMENTAL TESTING TO VERIFY THE EFFECTIVENESS OF THE BASE ISOLATION AND TUNED MASS DAMPERS COMBINED CONTROL STRATEGY L. Petti 1, G. Giannattasio 2, M. De Iuliis 3 1 Assistant Professor,
More informationSeismic Isolation with Friction Pendulum System. Nuno Miguel Canhão Esteves
Seismic Isolation with Friction Pendulum System Nuno Miguel Canhão Esteves July, 21 Summary This work aims to develop a pre-design routine for seismic protection solutions for buildings based in friction
More informationIncreasing hydro-equipment value with field measurements. P. Weibel, J. Contreras, S. Lais, E. Parkinson. ANDRITZ HYDRO Switzerland
IGHEM 2016, August 25 th to 26 th 2016, LINZ, AUSTRIA Increasing hydro-equipment value with field measurements P. Weibel, J. Contreras, S. Lais, E. Parkinson ANDRITZ HYDRO Switzerland INTRODUCTION The
More informationSEISMIC ANALYSIS OF BUILDING USING TWO TYPES OF PASSIVE ENERGY DISSIPATION DEVICES
SEISMIC ANALYSIS OF BUILDING USING TWO TYPES OF PASSIVE ENERGY DISSIPATION DEVICES G.S. Balakrishna 1, Jini Jacob 2 1 (Department of Civil Engineering, SSET/ M G University, India) 2 (Department of Civil
More informationVibrational Response of Structures Exposed to Human-induced Loads
Vibrational Response of Structures Exposed to Human-induced Loads Jonas Syders Knudsen, M.Sc., Nikolaj Grathwol, M.Sc. and Svend Ole Hansen, Ph.D.,2 Svend Ole Hansen ApS, Sankt Jørgens Allé 5C, 65 Copenhagen,
More informationStructural Health Monitoring
Workshop on EARTHQUAKE RESISTANCE OF LOW-COST ENGINEERED HOUSING IN NORTH-EAST INDIA 24-25 June 2016, IIT Guwahati Structural Health Monitoring Dr. Koushik Roy Assistant Professor IIT Patna Dr. Suparno
More informationFatigue Life Prediction of Steam Turbine Blades during Start-up Operation Using Probabilistic Concepts
Fatigue Life Prediction of Steam Turbine Blades during Start-up Operation Using Probabilistic Concepts Presenter: C Booysen Academic Mentor: Prof P.S Heyns Date: 2014/07/25 Outline Problem statement Fatigue
More informationAvailable online at ScienceDirect. Procedia CIRP 34 (2015 ) th International Conference on Axiomatic Design ICAD 2015
Available online at www.sciencedirect.com ScienceDirect Procedia CIRP 34 (2015 ) 206 211 9th International Conference on Axiomatic Design ICAD 2015 Redesigning a manufacturing system based on functional
More informationFlood control and safety evaluation of Banqiao reservoir
Available online at www.sciencedirect.com Procedia Engineering 8 (01) 368 375 01 International Conference on Modern Hydraulic Engineering Flood control and safety evaluation of Banqiao reservoir GUAN Tie-sheng
More informationFree vibrations and seismic responses of Shin Saikai Bridge and Saikai Bridge
Free vibrations and seismic responses of Shin Saikai Bridge and Saikai Bridge Kazuo Takahashi Department of Civil Engineering, Nagasaki University, Nagasaki, Japan Qingxiong Wu College of Civil Engineering,
More informationScienceDirect. Frequency Response of Sandwich Beam Embedded With Shape Memory Alloy Wires
Available online at www.sciencedirect.com ScienceDirect Procedia Materials Science 10 (2015 ) 638 643 2nd International Conference on Nanomaterials and Technologies (CNT 2014) Frequency Response of Sandwich
More informationDevelopment and Application of Intelligent Model Knowledge Base for the Plate Hot Leveler
Available online at www.sciencedirect.com Procedia Engineering 15 (2011 ) 1010 1014 Development and Application of Intelligent Model Knowledge Base for the Plate Hot Leveler Xiaogang Wang 1,a Hu Ying 1,b
More informationDYNAMIC RESPONSE ANALYSIS OF THE RAMA 9 BRIDGE EXPANSION JOINT DUE TO RUNNING VEHICLE
DYNAMIC RESPONSE ANALYSIS OF THE RAMA 9 BRIDGE EXPANSION JOINT DUE TO RUNNING VEHICLE Tanan Chub-uppakarn 1, Adison Owatsiriwong 2* 1 Department of Civil Engineering, Faculty of Engineering, Prince of
More informationTESTING A NEW PROCEDURE FOR DAMAGE DETECTION ON FRAMED STRUCTURES SUBJECTED TO STRONG MOTION EARTHQUAKES
TESTING A NEW PROCEDURE FOR DAMAGE DETECTION ON FRAMED STRUCTURES SUBJECTED TO STRONG MOTION EARTHQUAKES Rocco DITOMMASO, Felice Carlo PONZO, Gianluca AULETTA and Chiara IACOVINO ABSTRACT Structural Health
More informationSHM Application for Monitoring Existing Bridge Pier during Construction in Close Proximity
Structural Health Monitoring of Intelligent Infrastructure (SHMII-) 211 11 December 211, Cancún, México Abstract of Paper No: XXX SHM Application for Monitoring Existing Bridge Pier during Construction
More informationAbstract. 1. Introduction
Building monitoring during the partial implosion stage J. Garcés 1, J.C. Botero 1, D. Murià-Vila 2 (1) Universidad EAFIT - Colombia, (2) Instituto de Ingeniería- UNAM México Abstract The partial collapse
More informationPUNCHING RESEARCH AT UNIVERSIDADE NOVA DE LISBOA
2011 PUNCHING RESEARCH AT UNIVERSIDADE NOVA DE LISBOA A. Ramos 1, V. Lúcio 2, D. Faria 3, M. Inácio 4 Abstract At the Civil Engineering Department of Universidade Nova de Lisboa punching research has been
More informationSeismic analysis of dry stone masonry structures based on combined finite-discrete element method
Porto, Portugal, 30 June - 2 July 2014 A. Cunha, E. Caetano, P. Ribeiro, G. Müller (eds.) ISSN: 2311-9020; ISBN: 978-972-752-165-4 Seismic analysis of dry stone masonry structures based on combined finite-discrete
More informationSEISMIC ANALYSIS AND DYNAMIC TESTING OF A SPILLWAY RADIAL GATE
SEISMIC ANALYSIS AND DYNAMIC TESTING OF A SPILLWAY RADIAL GATE Wendy E DANIELL 1 And Colin A TAYLOR 2 SUMMARY The radial flood gate at Kilmorack Dam in Scotland was evaluated for seismic loading. The study
More informationSTRAIN-RATE INFLUENCE ON A SHAPE MEMORY ALLOY BASED DAMPER
Proceedings IRF2018: 6th International Conference Integrity-Reliability-Failure Lisbon/Portugal 22-26 July 2018. Editors J.F. Silva Gomes and S.A. Meguid Publ. INEGI/FEUP (2018); ISBN: 978-989-20-8313-1
More informationConstruction and Building Materials
Construction and Building Materials 24 (200) 33 339 Contents lists available at ScienceDirect Construction and Building Materials journal homepage: www.elsevier.com/locate/conbuildmat Review The influence
More informationBuilding damage due to structural pounding during earthquakes
Journal of Physics: Conference Series PAPER OPEN ACCESS Building damage due to structural pounding during earthquakes To cite this article: B Sotysik and R Jankowski 215 J. Phys.: Conf. Ser. 628 124 View
More informationExperimental and finite element vibration analysis of biaxial voided flat slab
Experimental and finite element vibration analysis of biaxial voided flat slab Michal Venglar 1, Kristina Zabakova Vrablova 2, Norbert Jendzelovsky 3, Milan Sokol 4 Slovak University of Technology in Bratislava,
More informationMain Drivers for the Iberian Market Price And Energy Storage in Portugal
Sustainable Energy Systems Main Drivers for the Iberian Market Price And Energy Storage in Portugal Gonçalo Pereira Susana Vieira Carlos Silva OR 2012, Hannover, Germany, 5/9/2012, contact: goncalo.duarte.pereira@ist.utl.pt
More informationCONTROL EFFECT OF LARGE TUNED MASS DAMPER APPLIED TO EXISTING HIGH-RISE BUILDING FOR SEISMIC RETROFIT
17th U.S.-Japan-New Zealand Workshop on the Improvement of Structural Engineering and Resilience CONTROL EFFECT OF LARGE TUNED MASS DAMPER APPLIED TO EXISTING HIGH-RISE BUILDING FOR SEISMIC RETROFIT N.
More informationSEISMIC RESPONSE ANALYSIS OF A SEMI-ACTIVE-CONTROLLED BASE-ISOLATED BUILDING DURING THE 2011 GREAT EAST JAPAN EARTHQUAKE
Proceedings of the International Symposium on Engineering Lessons Learned from the 2 Great East Japan Earthquake, March -4, 22, Tokyo, Japan SEISMIC RESPONSE ANALYSIS OF A SEMI-ACTIVE-CONTROLLED BASE-ISOLATED
More informationJob shop flow time prediction using neural networks
Available online at www.sciencedirect.com ScienceDirect Procedia Manufacturing 00 (2017) 000 000 This copy has been created with permission of Elsevier and is reserved to FAIM2017 conference authors and
More informationA field investigation of vibration-based structural health monitoring in a steel truss bridge
IABSE-JSCE Joint Conference on Advances in Bridge Engineering-II, August 8, 2, Dhaka, Bangladesh. ISBN: 978-984-33893- Amin, Okui, Bhuiyan (eds.) www.iabse-bd.org A field investigation of vibration-based
More informationAvailable online at ScienceDirect. Procedia Engineering 154 (2016 )
Available online at www.sciencedirect.com ScienceDirect Procedia Engineering 154 (2016 ) 1319 1323 12th International Conference on Hydroinformatics, HIC 2016 Modeling of floods and flood control water
More informationPathology examination of RC stadium stands through in-situ live load dynamic tests
Pathology examination of RC stadium stands through in-situ live load dynamic tests Jorge I. CRUZ-DIAZ 1, Jorge RUIZ-GARCÍA 2 1 Universidad Michoacana de San Nicolás de Hidalgo, Facultad de Ingeniería Civil,
More informationDFE... The Evolution in Filter Element Multi-Pass Development Testing Hy-Pro s Competitive Advantage
... The Evolution in Filter Element Multi-Pass Development Testing Hy-Pro s Competitive Advantage Fluxa Filtri S.p.A. V.le A.De Gasperi, 88/B - 217 Mazzo di Rho (MI) Italy Tel. +39 2.93959.1 (15 linee)
More informationDegradation of Concrete Bridges by Internal Expansive Reactions Portuguese Case Studies
Degradation of Concrete Bridges by Internal Expansive Reactions Portuguese Case Studies António Santos Silva, Arlindo Gonçalves, Manuela Salta Materials Department, Laboratório Nacional de Engenharia Civil,
More informationAN EXPERIMENTAL INVESTIGATION OF A MULTIPLE-TUNED- MASS-DAMPER-STRUCTURE SYSTEM WITH SOIL-STRUCTURE INTERACTION
AN EXPERIMENTAL INVESTIGATION OF A MULTIPLE-TUNED- MASS-DAMPER-STRUCTURE SYSTEM WITH SOIL-STRUCTURE INTERACTION Raz JABARY and Gopal MADABHUSHI ABSTRACT A tuned mass damper (TMD) is a popular vibration
More informationDamage assessment of hollow core reinforced and prestressed concrete slabs subjected to blast loading
Available online at www.sciencedirect.com ScienceDirect Procedia Engineering 199 (2017) 2476 2481 X International Conference on Structural Dynamics, EURODYN 2017 Damage assessment of hollow core reinforced
More informationEARTHQUAKE SAFETY OF EXISTING DAMS
EARTHQUAKE SAFETY OF EXISTING DAMS Dr. Martin Wieland Chairman, ICOLD Committee on Seismic Aspects of Dam Design Pöyry Energy Ltd., Zurich, Switzerland Formerly Electrowatt-Ekono Ltd. LARGE DAMS IN SWITZERLAND
More informationScienceDirect. Force prediction of cylindrical steel beams on pinned-pinned supports under axial load by vibration technique
Available online at www.sciencedirect.com ScienceDirect Procedia Engineering 95 (14 ) 178 184 nd International Conference on Sustainable Civil Engineering Structures and Construction Materials 14 (SCESCM
More informationOPTWASTEWATER: A COMPUTER PROGRAM FOR REGIONAL WASTEWATER SYSTEM PLANNING
OPTWASTEWATER: A COMPUTER PROGRAM FOR REGIONAL WASTEWATER SYSTEM PLANNING ABSTRACT OptWastewater, an easy-to-use computer program developed for regional wastewater system planning, is presented in this
More informationSeismic Analysis of RC Shear Wall Frame Buildings with and Without Openings in Shear Wall
Seismic Analysis of RC Shear Wall Frame Buildings with and Without Openings in Shear Wall Syed Mohammad Umar 1, Rizwanullah 2 1M-Tech (Structure and Foundation Engineering), 2 Assistant Professor Department
More informationKEYNOTE LECTURES REGULAR SESSIONS. Special Sessions AND mini-symposia. SESSION index
Continuous Monitoring of a Large Concrete Arch Dam Using Fibre Bragg Grating Sensors W. Lienhart, F. Klug. Graz University of Technology - Austria Abstract Conventional structural monitoring systems of
More informationEvaluation of the Effects of Dynamic Excitation Characteristics on Ambient Vibration Test Results for a Multi-Girder Bridge
University of Arkansas, Fayetteville ScholarWorks@UARK Civil Engineering Undergraduate Honors Theses Civil Engineering 5-2014 Evaluation of the Effects of Dynamic Excitation Characteristics on Ambient
More informationStructural Evaluations of Bridges with Smartphones
University of Nebraska - Lincoln DigitalCommons@University of Nebraska - Lincoln UCARE Research Products UCARE: Undergraduate Creative Activities & Research Experiences Spring 4-15-2016 Structural Evaluations
More informationSTRUCTURAL HEALTH MONITORING AT THE PONT DE LA POYA, FRIBOURG
Ref: WhP_Poya_SE_vA STRUCTURAL HEALTH MONITORING AT THE PONT DE LA POYA, FRIBOURG WHITE PAPER Summary: This white paper shows how Structural Health Monitoring (SHM), helps to improve the quality in the
More informationOn the complexity of production planning and scheduling in the pharmaceutical industry: the Delivery Trade-offs Matrix
Krist V. Gernaey, Jakob K. Huusom and Rafiqul Gani (Eds.), 12th International Symposium on Process Systems Engineering and 25th European Symposium on Computer Aided Process Engineering. 31 May 4 June 2015,
More informationAvailable online at ScienceDirect. Procedia Engineering 89 (2014 )
Available online at www.sciencedirect.com ScienceDirect Procedia Engineering 89 (2014 ) 206 212 16th Conference on Water Distribution System Analysis, WDSA 2014 Autonomous VPS-Based Manganese Prediction
More informationFIELD EXPERIMENT ON STEEL INDUSTRIAL BUILDING WITH AMBIENT VIBRATION
FIELD EXPERIMENT ON STEEL INDUSTRIAL BUILDING WITH AMBIENT VIBRATION Elif AĞCAKOCA 1, H. Serdar KUYUK 2, Muharrem AKTAŞ 3, Elif O. BORU 4, Erkan ÇELEBİ 5 ABSTRACT Understanding the dynamic behavior of
More informationANALYSIS OF THE SEISMIC RESPONSE OF A DAMAGED MASONRY BELL TOWER
ANALYSIS OF THE SEISMIC RESPONSE OF A DAMAGED MASONRY BELL TOWER 19 Giovanni BONGIOVANNI 1, Paolo CLEMENTE And Giacomo BUFFARINI 3 SUMMARY The dynamic behavior of an earthquake damaged masonry bell tower
More informationFlood Risk Analysis of Bridge A Case Study
ISBN 978-93-84468-11-8 Proceedings of International Conference on Architecture And Civil Engineering (ICAACE'14) Dubai, December 25-26, 2014, pp. 128-134 Flood Risk Analysis of Bridge A Case Study Safa
More informationSEISMIC SOIL-STRUCTURE INTERACTION (SSI) EFFECTS FOR A DIFFERENT TYPE OF BUILDINGS IN DENSE URBAN AREA
SEISMIC SOIL-STRUCTURE INTERACTION (SSI) EFFECTS FOR A DIFFERENT TYPE OF BUILDINGS IN DENSE URBAN AREA Ovidiu BOGDAN 1, Dan M. GHIOCEL 2 and Dan CRETU 3 ABSTRACT The paper presents the results of a project
More informationWall base ventilation system as a new technique to treat rising damp in existent buildings Received (in revised form): 24th July 2009
Original Article Wall base ventilation system as a new technique to treat rising damp in existent buildings Received (in revised form): 24th July 2009 Ana Sofia Guimarães is Lecturer since 2005 at DEC,
More informationTENSILE STRESSES IN CONCRETE DAMS
Water Power and Dam Construction, April, 2005 TENSILE STRESSES IN CONCRETE DAMS Dr. Martin Wieland Chairman, ICOLD Committee on Seismic Aspects of Dam Design, c/o Electrowatt-Ekono Ltd. (Jaakko Pöyry Group),
More informationAvailable online at ScienceDirect. Procedia Engineering 186 (2017 )
Available online at www.sciencedirect.com ScienceDirect Procedia Engineering 186 (2017 ) 193 201 XVIII International Conference on Water Distribution Systems Analysis, WDSA2016 Demand Estimation In Water
More informationModal Analysis of a Steel Radial Gate Exposed to Different Water Levels
Archives of Hydro-Engineering and Environmental Mechanics Vol. 64 (2017), No. 1, pp. 37 47 DOI: 10.1515/heem-2017-0003 IBW PAN, ISSN 1231 3726 Modal Analysis of a Steel Radial Gate Exposed to Different
More informationResponse Analysis of an RC Cooling Tower Under Seismic and Windstorm Effects D. Makovička
Response Analysis of an RC Cooling Tower Under Seismic and Windstorm Effects D. Makovička The paper compares the RC structure of a cooling tower unit under seismic loads and under strong wind loads. The
More informationMADA MAsonry DAtabase
Online experimental data selection for mechanical modelling of masonry last update on February 6, 2015 Department of Structures for Engineering and Architecture, University of Naples Federico II augenti@unina.it;
More informationStudy of Modal Analysis Techniques to Evaluate the Damage Condition of RC Bridges with Heaving Moving Loads
Study of Modal Analysis Techniques to Evaluate the Damage Condition of RC Bridges with Heaving Moving Loads S.A.C.N Wimalasuriya 1, Rajapaksha R.G.S.H 1, De Silva Sudhira 1 and De Silva Subashi 1 1 Department
More informationGenetic Algorithm for Flexible Job Shop Scheduling Problem - a Case Study
Genetic Algorithm for Flexible Job Shop Scheduling Problem - a Case Study Gabriela Guevara, Ana I. Pereira,, Adriano Ferreira, José Barbosa and Paulo Leitão, Polytechnic Institute of Bragança, Campus Sta
More informationFull scale experimental performance assessment of a prefabricated timber panel for the energy retrofitting of multi-rise buildings
Available online at www.sciencedirect.com ScienceDirect Energy Procedia 122 (2017) 3 8 www.elsevier.com/locate/procedia CISBAT 2017 International Conference Future Buildings & Districts Energy Efficiency
More informationAmbient Vibration Testing of Three Unreinforced Brick Masonry Buildings in Vancouver, Canada
Ambient Vibration Testing of Three Unreinforced Brick Masonry Buildings in Vancouver, Canada Abstract Martin Turek 1, Katherine Thibert 1, Carlos Ventura 2 and Steven Kuan 3 (1) Graduate Students (2) Professor
More informationDynamic Characteristics Analysis of Large Self-anchored Suspension Bridge
Modern Applied Science; Vol. 8, No. 2; 2014 ISSN 1913-1844 E-ISSN 1913-1852 Published by Canadian Center of Science and Education Dynamic Characteristics Analysis of Large Self-anchored Suspension Bridge
More informationA Study on Physical Model Test for Cheongpyeong Dam Discharge Recalculation
Engineering, 014, 6, 731-74 Published Online October 014 in SciRes. http://www.scirp.org/journal/eng http://dx.doi.org/10.436/eng.014.611071 A Study on Physical Model Test for Cheongpyeong Dam Discharge
More informationANALYSIS OF TIME OSCILLATIONS OF WATER ON LAKE MODRIC AS A MULTI-PURPOSE RESERVOIR
Original Scientific paper UDC 628.258:550.38 DOI: 10.7251/afts.2018.1018.031S COBISS.RS-ID 7323160 ANALYSIS OF TIME OSCILLATIONS OF WATER ON LAKE MODRIC AS A MULTI-PURPOSE RESERVOIR Suljić Nedim 1, Kovčić
More informationAvailable online at ScienceDirect. Procedia Computer Science 60 (2015 )
Available online at www.sciencedirect.com ScienceDirect Procedia Computer Science 60 (2015 ) 413 421 19th International Conference on Knowledge Based and Intelligent Information and Engineering Systems
More informationSTABLE SYSTEMS IN UNSTABLE CONDITIONS: EARTHQUAKE TESTING CONFORM THE IBC
STABLE SYSTEMS IN UNSTABLE CONDITIONS: EARTHQUAKE TESTING CONFORM THE IBC Paul SCHOTEN Eaton Holec The Netherlands holec-info@eaton.com Bob TOWNE Eaton Cutler-Hammer United States of America Mostafa AHMED
More informationAvailable online at ScienceDirect. Procedia Engineering 89 (2014 )
Available online at www.sciencedirect.com ScienceDirect Procedia Engineering 89 (2014 ) 1031 1036 16th Conference on Water Distribution System Analysis, WDSA 2014 Dynamic day-ahead water pricing based
More informationLinear and Nonlinear Seismic Analysis of a Tall Air Traffic Control (ATC) Tower
Linear and Nonlinear Seismic Analysis of a Tall Air Traffic Control (ATC) Tower A. Adnan, M. Vafaei & A.K. Mirasa Faculty of Civil Engineering, Universiti Teknologi Malaysia SUMMARY: Air Traffic Control
More informationKeywords: Fish ladder, Investigation of Upstream Migration, Sweetfish, Fish Straying Prevention Device, Sodium Lamp Lighting
IEA Hydropower Implementing Agreement Annex VIII Hydropower Good Practices: Environmental Mitigation Measures and Benefits Case study 03-02: Fish Migration and River Navigation - Funagira Power Plant,
More informationPerformance Based Seismic Design and Assessment of Irregular Steel Structures
Performance Based Seismic Design and Assessment of Irregular Steel Structures R. Peres, R. Bento IST, Technical University of Lisbon, Portugal J. M. Castro Faculty of Engineering, University of Porto,
More informationAMBIENT VIBRATION ANALYSIS FOR THE CHARACTERIZATION OF SOIL AND COVERINGS OF VILLA DEI MISTERI IN POMPEII
SAHC1 9 th International Conference on Structural Analysis of Historical Constructions F. Peña & M. Chávez (eds.) Mexico City, Mexico, 1 17 October 1 AMBIENT VIBRATION ANALYSIS FOR THE CHARACTERIZATION
More informationRisk analysis of the Kaunas hydropower system
Risk analysis of the Kaunas hydropower system J. Augutis 1, J. Simaityte Volskiene 2 & E. Uspuras 2 & J. Kriauciuniene 2 1 Vytautas Magnus University, Lithuania 2 Lithuanian Energy Institute, Lithuania
More informationAvailable online at ScienceDirect. XVII International Colloquium on Mechanical Fatigue of Metals (ICMFM17)
Available online at www.sciencedirect.com ScienceDirect Procedia Engineering 74 ( 2014 ) 253 260 XVII International Colloquium on Mechanical Fatigue of Metals (ICMFM17) LCF and TMF on ferritic stainless
More informationEARTHQUAKE RESPONSE ANALYSIS OF MID-STORY BUILDINGS ISOLATED WITH VARIOUS SEISMIC ISOLATION TECHNIQUES
EARTHQUAKE RESPONSE ANALYSIS OF MID-STORY BUILDINGS ISOLATED WITH VARIOUS SEISMIC ISOLATION TECHNIQUES N. Torunbalci 1 and G. Ozpalanlar 2 1 Assoc. Professor Dr., Dept. of Structural Engineering, Faculty
More informationOPERATIONAL MODAL ANALYSIS FOR DAMAGE DETECTION OF A MASONRY CONSTRUCTION
OPRATIONAL MODAL ANALYSIS FOR DAMAG DTCTION OF A MASONRY CONSTRUCTION Luís F. Ramos, Dep. Civil ngineering, University of Minho, Portugal Alfredo Campos Costa, LNC, Portugal Paulo B. Lourenço, Dep. Civil
More informationImproving the benchmarking of social media content strategies using clustering and KPI
Available online at www.sciencedirect.com ScienceDirect Procedia Computer Science 121 (2017) 826 834 CENTERIS - International Conference on ENTERprise Information Systems / ProjMAN - International Conference
More informationSeismic Analysis and Design of Vertically Irregular RC Building Frames
Seismic Analysis and Design of Vertically Irregular RC Building Frames Himanshu Bansal 1, Gagandeep 2 1 Student (M.E.), PEC University of Technology, Civil Department, Chandigarh, India 2 Student (M.E.),
More information