Ammonia-Based Feedforward and Feedback Aeration Control in Activated Sludge Processes

Size: px
Start display at page:

Download "Ammonia-Based Feedforward and Feedback Aeration Control in Activated Sludge Processes"

Transcription

1 Ammonia-Based Feedforward and Feedback Aeration Control in Activated Sludge Processes Leiv Rieger 1 *, Richard M. Jones 1, Peter L. Dold 1, Charles B. Bott 2 ABSTRACT: Aeration control at wastewater treatment plants based on ammonia as the controlled variable is applied for one of two reasons: (1) to reduce aeration costs, or (2) to reduce peaks in effluent ammonia. Aeration limitation has proven to result in significant energy savings, may reduce external carbon addition, and can improve denitrification and biological phosphorus (bio-p) performance. Ammonia control for limiting aeration has been based mainly on feedback control to constrain complete nitrification by maintaining approximately one to two milligrams of nitrogen per liter of ammonia in the effluent. Increased attention has been given to feedforward ammonia control, where aeration control is based on monitoring influent ammonia load. Typically, the intent is to anticipate the impact of sudden load changes, and thereby reduce effluent ammonia peaks. This paper evaluates the fundamentals of ammonia control with a primary focus on feedforward control concepts. A case study discussion is presented that reviews different ammonia-based control approaches. In most instances, feedback control meets the objectives for both aeration limitation and containment of effluent ammonia peaks. Feedforward control, applied specifically for switching aeration on or off in swing zones, can be beneficial when the plant encounters particularly unusual influent disturbances. Water Environ. Res., 86, 63 (2014). KEYWORDS: aeration control, ammonia-based control, feedforward control, feedback control, energy savings, wastewater treatment. doi: / x Introduction Ammonia-based aeration control of the activated sludge process can lead to significant aeration energy savings, and potential performance improvements for nitrogen and biological phosphorus (bio-p) removal plants. Several studies report that ammonia control leads to energy savings in the range of 15 to 25%, and to significant increases in nitrogen removal. Table 1 lists data from selected ammonia control case studies. An extensive list is provided in a recent review of aeration control at water resource recovery facilities (WRRFs) (Åmand et al., 2013). Recently, ammonia feedforward control has received much attention for optimal aeration of activated sludge systems (e.g., Vrečko et al., 2011; Sunner et al., 2009; Liu et al., 2005; Walz et al., 2009; Yong et al., 2005; Shen et al., 2011). This paper aims to clarify some of the misconceptions about this control concept. The first step is to separate (1) the advantages and disadvantages of ammonia control from (2) how to best implement ammonia 1 * EnviroSim Associates Ltd., McMaster Innovation Park, 175 Longwood Rd S, Suite 114A, Hamilton, Ontario, L8P 0A1, Canada; rieger@inctrl.ca. 2 Hampton Roads Sanitation District, Virginia Beach, Virginia. control; that is, a discussion of feedforward versus feedback control concepts. The paper begins with an overview of the underlying reasons for applying ammonia control including consideration of the nitrification process and aeration requirements, and potential causes of ammonia peaks. This is followed by a general discussion regarding the goals of feedforward control and the inherent dangers. A section on ammonia feedforward control examines the advantages and disadvantages of this control concept, and includes an overview of ammonia feedforward controller types. Situations are identified that reveal when feedforward control is beneficial, and when it is not beneficial. A case study of the Hampton Roads Sanitation District s Nansemond WRRF is presented to illustrate the impact of different ammonia-based control strategies, including feedback and feedforward concepts. Nitrification and Effluent Ammonia. Nitrification is implemented in many activated sludge plants to maintain an effluent ammonia concentration lower than a permit level (e.g., 3 mgn/ L), and often as a precursor to denitrification where there is an effluent total nitrogen limit. Effluent limits are typically applied because residual ammonia may cause a critical oxygen deficit in the receiving water, potentially resulting in harm to the environment. Additionally, at high ph levels and high temperatures, the ammonium/ammonia equilibrium favors a greater free ammonia concentration, which may be toxic for aquatic and marine biota. Conversion of ammonia to nitrate by a nitrifying biomass requires sufficient dissolved oxygen, ammonia as substrate, a number of nutrients, and a sufficiently long aerobic sludge retention time (SRT) to avoid washout of nitrifiers. Nitrification is a two-step process: (1) ammonia oxidizing bacteria (AOB) convert ammonia to nitrite, and (2) nitrite oxidizing bacteria (NOB) oxidize nitrite to nitrate. In most nitrification plants, an objective is to maintain dissolved oxygen at approximately 2 mg/l, typically resulting in complete nitrification with low residual effluent ammonia which is often substantially lower than the permit level. In many instances (higher temperatures and long SRT), the effluent ammonia may be in the range of 0.1 to 0.2 mgn/l over a one day period. However, nitrifying plants are typically based on plug flow designs; more often than not, the effluent shows some breakthrough of ammonia at the high influent load time of day, even if dissolved oxygen levels are maintained at roughly 2 mg/l. Figure 1 shows a typical ammonia profile over 48 hours at the aeration tank outlet and in the secondary effluent from a fully nitrifying plant. Effluent ammonia spikes may be critical for plants with never-to-exceed permit limits. The peak in January

2 Table 1 Selected ammonia-control case studies. Reduction in air flow requirements 1 (%) Increase in total nitrogen removal (%) Decrease in external carbon (%) Reference Nielsen and Önnerth, Husmann et al., Ingildsen et al., Liu et al., (2 mgn/l in effluent) Ayesa et al., Sunner et al., Walz et al., Rieger et al., 2012a Rieger et al., 2012a 1 The reference for all case studies is dissolved oxygen control. 2 In addition, internal recycle control has been introduced. effluent ammonia is an expected kinetic-stoichiometric consequence. It is important to recognize that the mass of nitrifiers in the system is set by the average ammonia load (i.e., the mass of ammonia converted to nitrate) and the SRT. The nitrifier mass changes slowly from day to day. Under the diurnal flow and load patterns, the ammonia loading rate may fluctuate substantially during the day; however, the nitrifier mass is essentially constant. Although the mass of nitrifying organisms may remove ammonia at the maximum rate during the high load time of day, frequently not all of the ammonia load will be nitrified resulting in the breakthrough of ammonia in the effluent. This is a kinetic limitation and the situation is exacerbated if one, or both, of the following conditions are true: (1) the plant receives shock ammonia loads, (2) the aeration system cannot maintain sufficient dissolved oxygen levels in all parts of the aerated zones. Methods for reducing the breakthrough include increasing overall SRT, equalizing the load, utilizing sludge storage (Yuan et al., 2000), or augmentation concepts (e.g., Salem et al., 2002; Krhutkovaì et al., 2006). Raising dissolved oxygen higher than 1.5 to 2 mg/l will likely have no impact. When dissolved oxygen exceeds approximately 1.5 mg/l, the nitrification rate is essentially no longer limited by dissolved oxygen (Figure 2). Reducing the wastage rate to increase SRT will result in a slow change in nitrifier mass over a period of days and weeks, and the impact on nitrification will be slow. Aside from equalizing the load, the only option for an immediate improvement in nitrification to reduce the effluent peak is to increase the aerated SRT (e.g., switch on aeration in swing zones at appropriate times). A first step in evaluating ammonia control for reducing effluent peaks should be to determine the causes and extent of input ammonia peaks. A detailed analysis is given in Gujer and Erni (1978). Frequently, ammonia peaks have operational causes (e.g., non-optimal reject water dosage or other internal recycles). These operation-induced problems might be addressed more easily than utilization of a complex control system. Typically, ammonia peaks are more probable in small catchments; however, payback of additional instrumentation may not be justified (Devisscher et al., 2006). Large plants typically have large catchments and more attenuated flows and loads (Gujer and Erni, 1978). Table 2 lists several potential causes of ammonia peaks. Several factors impact aeration requirements other than the nitrification oxygen demand for autotrophic organisms that convert ammonia to nitrate. The primary factors are: oxygen demand from heterotrophic organisms for removal of organic matter (carbonaceous oxygen demand); a reduction in oxygen demand as a result of organic matter that is oxidized using nitrite or nitrate in place of oxygen as an electron acceptor under anoxic conditions (i.e., an oxygen credit ); the load of reduced inorganic matter (e.g., sulfide or ferrous iron) which, in most cases, should be insignificant compared with carbonaceous and nitrification oxygen requirements; aeration to raise low dissolved oxygen streams to the dissolved oxygen concentration in aerated reactors; oxygen transfer efficiency (the amount of oxygen in the diffused air that is transferred to the liquid to satisfy the oxygen demand); and air flow requirements for mixing. (This should not be ignored because it often limits the turn-down capacity for the entire aeration system, and constrains the potential for aeration reduction and cost savings.) Ammonia-Based Aeration Control. Aeration control based on ammonia measurement is essentially applied for one of two reasons: (1) to limit aeration (aeration is limited to allow an elevated effluent ammonia concentration close to the permit Figure 1 Ammonia concentration at aeration tank outlet and in secondary effluent. 64 Water Environment Research, Volume 86, Number 1

3 Table 2 Potential causes of ammonia peaks and ways to deal with them. Cause of peak Internal/external cause Potential solutions Ammonia-rich reject water or Internal Equalize reject water. other recycle dosage. Septage dosage. Internal Equalize. Storm event pushing ammonia-rich content of primaries (or sewer) External Storm tanks to reduce hydraulic overload; bypass parts of plant. through plant. Industrial discharge. External Source control, equalize, pre-treatment on site. Figure 2 Monod term for dissolved oxygen (DO) dependency of nitrification at half-saturation constant of 0.5 mg/l. limit [i.e., to prevent complete nitrification]; the potential benefits include energy savings, increased denitrification, and in some cases, improved bio-p performance.), or (2) to reduce effluent ammonia peaks (aeration is manipulated to reduce the extent of effluent ammonia peaks). Ammonia-based aeration control for both objectives can be implemented using either feedback or feedforward control. This section provides background for the two cases, and details of the control structures are discussed later. Case of Limiting Aeration. The first case limits aeration to prevent complete nitrification, and maintain effluent ammonia concentration at a setpoint of typically 1 to 2 mgn/l. (The exact setpoint will depend on factors such as whether the effluent permit is based on a grab sample or a flow-weighted average value.) The intent of this control approach is to elevate ammonia levels by a small amount while still maintaining the effluent ammonia permit. Figure 1 shows that for much of the day, the effluent ammonia concentration is very low (less than 0.1 mg/l), probably much lower than the effluent permit level. In this situation, ammonia-based aeration control can be applied to cut back aeration over much of the day, thereby lowering dissolved oxygen and limiting nitrification. As compared to complete nitrification, the reduced aeration will result in energy savings. The low dissolved oxygen should lead to increased denitrification, and in some cases, better bio-p performance. Over-aeration at the peak load period during the day is a potential issue with ammonia control on its own. Effluent ammonia may increase above the setpoint over the high load time of day (a peak in effluent ammonia occurs for the reasons previously outlined). The response of the ammonia controller would be to increase aeration. However, in this situation nitrification performance is limited by the nitrifier mass; increasing dissolved oxygen above 1.5 mg/l will have no impact. For this reason, ammonia controllers typically should be used in conjunction with dissolved oxygen limits to prevent overaeration at high ammonia concentrations. The ammonia controller can resume control authority when the peak has passed. One of two approaches is typically used for implementing limited aeration ammonia-based control (Åmand et al., 2013): (1) a cascade controller is used where the ammonia controller determines and changes the dissolved oxygen setpoint for a controller adjusting air flow; or (2) a control concept is used where the ammonia controller manipulates the air flow directly. The first approach is generally preferred because the slower ammonia control loop manipulates the setpoint of the faster dissolved oxygen control loop. This simplifies control system tuning. In addition, with this approach the ammonia part can be switched off (or even fail); the dissolved oxygen controller will then serve as a stand-alone fall-back strategy. Because the dissolved oxygen controller is active at all times, adequate process control should be achieved, even if the system reverts to a fall-back situation. Establishing a fall-back strategy with direct ammonia control of air flow is more difficult. In the second approach of direct ammonia control, a dissolved oxygen sensor should still be installed to limit the air flow when the dissolved oxygen is above a defined concentration (e.g., 2 mg/l). This will prevent over-aeration at high ammonia load. Therefore, both control concepts require monitoring of ammonia and dissolved oxygen to avoid a difference in sensor costs. Figure 3 Schematic representation of feedback controller. January

4 Figure 4 Schematic representation of feedforward controller. When implementing direct ammonia control, special care should be taken when tuning the control loops, because changes in dissolved oxygen concentration occur much faster than changes in ammonia concentration. Because ammonia is the driving control loop and dissolved oxygen is used only as a constraint, the control system may become unstable when the dissolved oxygen constraint applies, unless the controllers are carefully tuned. An advantage of direct ammonia control is that fewer air flow changes may be necessary because of the slower concentration changes of ammonia as compared with dissolved oxygen. This will be favorable for the blower and associated aeration control equipment. Ammonia control for limiting aeration may impact a number of factors in plant performance: For typical municipal nitrifying plants, ammonia control reduces aeration, although should have no impact on biochemical oxygen demand removal. The carbonaceous oxygen requirements will be satisfied if complete (or near complete) nitrification is achieved. A further quoted advantage of ammonia control is that plant performance becomes more stable. In plug flow nitrifying plants, there is often a sudden drop in oxygen demand at the point in the bioreactor where ammonia removal by nitrification is complete. The position of this point moves over the day, depending on the influent loading rate and temperature variations, making aeration control more difficult. Despite multiple dissolved oxygen control loops, it is difficult to account for this step change in oxygen demand. Depending on the location of the dissolved oxygen probes, this may lead to over-aeration of the downstream sections of the aerated bioreactors, even if diffuser tapering partly accounts for the oxygen demand profile. When using ammonia control, nitrification is never complete, and therefore, this problem is avoided. Increased denitrification occurs through simultaneous nitrification and denitrification at low dissolved oxygen concentrations (Münch et al., 1996; Jimenez et al., 2010); conventional denitrification occurs if aeration is switched off completely. It has been suggested that benefits may be gained from a denitrification shortcut where nitrite generated by AOB is reduced directly to nitrogen gas (also called nitrite shunt ) (Marcelino et al., 2011). This would lead to significant savings in aeration energy as compared to nitrifying all the way to nitrate, and reduced carbon needs for denitrification. However, elevated nitrite levels may lead to increased nitrous oxide emissions (Houweling et al., 2011; Kitamura et al., 2012). A recent study has demonstrated control of nitrous oxide emissions in a system using the nitrite shunt (Lemaire et al., 2011). Sustained low dissolved oxygen levels may cause accumulation of nitrite, thereby adversely impacting effluent disinfection, possibly reducing phosphorus uptake by phosphate-accumulating organisms, or even triggering sludge bulking and foaming issues. However, in contrast to studies with constant low dissolved oxygen (e.g. Martins et al., 2004), there is little evidence from ammonia-based aeration control studies to suggest that these are significant issues (Ingildsen et al., 2002; Rieger et al., 2012a). Case of Reducing Effluent Ammonia Peaks. The second case for ammonia-based aeration control is the perception that it offers a means to reduce the extent of effluent ammonia peaks. However, as previously noted, increasing the bioreactor dissolved oxygen above approximately 1.5 mg/l during a peak may have little effect because the nitrification rate is kinetically limited by the nitrifier mass. Essentially, it is a misconception that the aeration rate can be adjusted to reduce peaks in effluent ammonia. However, in certain cases, increasing dissolved oxygen may improve nitrification performance. For example, in systems with poor diffuser tapering, increasing aeration may raise dissolved oxygen in parts of the bioreactor where dissolved oxygen was limiting nitrification. However, this will cause over-aeration in other parts of the bioreactor. Nevertheless, it should be conceded that a special case exists when ammonia-based control is applied to maintain an elevated effluent ammonia concentration of approximately 1 to 3 mg/l. Figure 1 illustrates the effluent ammonia response (the ammonia peaks at 2 mg/l at the high load time). If aeration was limited to maintain ammonia at 2 mg/l between 12:00 a.m. and 12:00 p.m. rather than nitrifying completely, the maximum ammonia concentration at the peak would probably be in the range of 2 to 4 mg/l, and likely closer to 2 rather than 4 mg/l. This will depend on many factors such as the form of the influent loading pattern and the degree of plug flow in the aeration tanks. Additionally, when ammonia begins to increase, the controller will raise dissolved oxygen toward the upper limit, which will reduce the peak. For this ammonia control situation, and any high load condition, raising the bioreactor dissolved oxygen prior to the peak load and decreasing the ammonia concentration will provide a degree of buffer before the peak occurs. However, the extent of the buffering action depends on many factors and can only be evaluated through dynamic simulation. Essentially, the only strategy for significantly reducing effluent ammonia peaks without adding additional reactor volume (for sludge storage strategies see Yuan et al., 1998, 2000; for 66 Water Environment Research, Volume 86, Number 1

5 Figure 5 Planning, implementation, and operation phases of advanced aeration control systems. augmentation strategies see Salem et al., 2002 and Krhutkovaì et al., 2006) is to increase the aerated sludge mass in systems that include swing zones. An ammonia controller can be used to switch aeration on or off in the swing zone. This approach will have an immediate impact on nitrification performance by increasing the aerated fraction of the nitrifier mass. (A special case applies to oxidation ditches, where aerobic and anoxic zones are not clearly defined, and changes in aeration intensity will have an impact on the size of aerated zones.) As noted, ammonia-based aeration control for either of the two objectives (limiting aeration or reducing ammonia peaks) can be implemented using either feedback or feedforward control, or a combination of both. In each case the goal is the same, which is to maintain a desired (setpoint/reference) ammonia concentration. The following section presents the principles of feedback and feedforward control, followed by a critical discussion about the application of ammonia-based feedforward concepts for aeration control. Feedback versus Feedforward Control. Feedback control involves a measured process variable (controlled variable) that is input to the controller (e.g., bioreactor dissolved oxygen concentration). Control action is based on the difference (error) between the measured value and the desired value (setpoint/ reference). The objective is to reduce the error by the control action (e.g., by adjusting the air flow). Figure 3 shows a schematic of a feedback control loop. A feedforward controller measures a process disturbance (e.g., influent ammonia load) and uses a model to predict the behavior of the controlled system. The predictions are then used to calculate the control action to be taken (e.g., changing air flow or a dissolved oxygen setpoint). Again, the objective is to maintain the controlled variable at the setpoint/reference value; however, the controlled variable is not measured. Figure 4 shows a schematic representation of a feedforward controller. Control Structure Selection. Typically, a feedback control structure is preferable over a feedforward structure, because feedback control is based on the measured output of the process and does not require a model of the controlled system. A feedforward controller requires a model of the controlled system (Figure 4); therefore, it requires knowing the impact of potential disturbances and many other factors (e.g., ongoing bio-chemical and physico-chemical processes, physical dimensions, operational settings and hydraulics, and impacts of disturbances such as influent load and temperature). A possible criticism of feedback control is that an error must exist before a control action can be taken. In systems with short retention times, it may be too late to accommodate sudden disturbances because of long sensor or actuator response times, or slow reactions to control actions. A common argument for feedforward control is that potential disturbances are addressed before they actually disturb the plant. For example, if a peak is monitored upstream of the process unit, January

6 Figure 6 Model configuration of the Nansemond water resource recovery facility. adequate actions are potentially triggered to prepare the plant for the increased load (or flow). The intent of the feedforward controller is to use a time advantage to react more quickly to an influent disturbance which may otherwise exceed the capacity of the plant, resulting in an exceedance of effluent ammonia. The success of a feedforward controller is therefore measured in terms of its ability to accommodate disturbances and reduce impacts on effluent quality. In wastewater treatment, feedforward concepts are successfully applied in cases where a fast reaction to disturbances is required, and where the impact of the control action is simple to predict. Examples are flow control, dosage of precipitants for chemical phosphorus removal, or addition of external carbon based on an upstream signal. In such cases, using feedback concepts may lead to violation of effluent permits or oscillating controlled variables, because the measured signal is too late to compensate for the disturbances. Inherent Dangers of Feedforward Control. Feedforward control requires a potentially simple model to predict response in the downstream controlled system. A perfect feedforward controller requires a perfect model, because there is no information available to the controller regarding how the system responds to controller actions and disturbances, such as changing loadings, temperature, and SRT. Therefore, most feedforward controllers use a downstream signal to either adjust the model or trim the control action by feedback control, thereby accounting for deficiencies in the model. (Limits are also typically imposed on the control action; for example, a maximum dissolved oxygen concentration to avoid the over-aeration issue.) When applying feedforward control, special attention should be given to the inherent risk of prediction model failure and the potential violation of effluent limits. Disadvantages of Feedforward Controllers. A very simple model needs less input data but will have limited capability to predict how the process reacts to disturbances and controller actions. Although a complex model may be more accurate in its predictions, it will require several sensors as inputs. Therefore, as compared to feedback control, in most cases feedforward control concepts (1) need more sensors, (2) are more complex, (3) need increased maintenance/controller tuning, and (4) place an additional burden on operators. Selection Criteria. The preferred control structure depends on many factors including the influent load and temperature variations, the specific plant configuration, the response time of sensors, actuators and equipment such as blowers, and the effluent permit (limits and averaging time). When testing control strategies, one criterion is the control authority (Olsson and Newell, 1999), which is the ability of the controllers to maintain a given setpoint or track a trajectory of setpoints over a range of conditions (both increasing and decreasing disturbances). Regarding feedback versus feedforward control, the issue is whether the feedback controller can react within a reasonable time to maintain the controlled variable within an acceptable range around the setpoint. If the downstream signal is too late, and an earlier signal would be advantageous, the measurement point can be moved upstream (e.g., from effluent to last bioreactor). Feedforward control should only be used if: (1) the process dynamics are slow relative to the frequency and amplitude of the disturbances, (2) feedforward control actions have sufficient control authority and are able to reduce the impact of a disturbance, (3) the controlled system with potential disturbances can be described in a model with sufficient accuracy, and (4) the disturbances can be measured or reliably estimated on-line. Ammonia-Based Feedforward Control. This section focuses on a feedforward control structure for the two cases of aeration control (limiting aeration and reducing effluent ammonia peaks). Advantages and possible pitfalls of feedforward ammonia-based aeration control are discussed. Ammonia Feedforward Control for Limiting Aeration. The intent of a feedforward controller is to use a time advantage to react rapidly to an influent peak, which otherwise may exceed the capacity of the plant. If the control goal is to limit aeration, and thereby save energy and improve denitrification, feedforward concepts may not be the best choice for the following reasons: Effluent ammonia concentration typically changes slowly in activated sludge plants because the influent load disturbances are usually slow and disturbances are attenuated through the long retention time process. In most instances, ammonia feedback control is sufficiently fast and provides acceptable control authority to maintain an ammonia setpoint within reasonable bounds. Introducing feedforward control at these plants would not provide any additional benefits. Feedforward control should include safety factors against model prediction inaccuracies. Therefore, the potential cost savings and other benefits from ammonia control may not be fully realized. 68 Water Environment Research, Volume 86, Number 1

7 Table 3 Selected control strategies tested in Rieger et al. (2012b). Control strategy Strategy 1 (base case): dissolved oxygen control. Strategy 2b: NH 4 feedback (FB). Strategy 4: NH 4 feedforward (FF) aeration intensity plus FB. Strategy 5 (new scenario): NH 4 FF aerated volume plus FB. Description Existing strategy: dissolved oxygen control to fixed setpoints in three aeration zones. Ammonia feedback control (PID 1 ) changing the dissolved oxygen setpoints between 0 2 mg/l. Feedforward/feedback ammonia aeration intensity control changing dissolved oxygen setpoints between mg/l. Selection of active control loop based on loop requesting higher dissolved oxygen. Feedforward ammonia control switching swing zone aeration on/off (aerated volume control); feedback ammonia control changing dissolved oxygen setpoint between 0 2 mg/l. 1 PID controller ¼ proportional-integral-derivative controller. For most plants, the lack of control authority to maintain an ammonia setpoint as a result of ammonia load variations is not caused by a delayed signal in a feedback control system; rather, it is because of the limited mass of nitrifiers in aerobic bioreactors. An early increase of aeration intensity can provide a certain buffer capacity although is not able to provide more nitrifiers. Limiting aeration (reducing the aeration intensity) has a one-sided control authority. It is effective for limiting the nitrification rate by reducing dissolved oxygen, however, it is not able to increase nitrification capacity. An early control action can be used to create a buffer for incoming ammonia load peaks, although the feedforward model must be accurate in terms of predicted nitrification capacity and in determining the point when increased aeration intensity is required. Inaccurate models may result in an unnecessary increase in energy consumption or reduced plant performance. Methods of addressing ammonia peaks are further discussed in the following section. Ammonia Feedforward Control for Reducing Ammonia Effluent Peaks. Typically, feedforward concepts are applied when effluent peaks must be reduced; in this case, effluent ammonia peaks. A first step in evaluating ammonia control strategies is to analyze whether feedforward control is necessary, or whether a simple feedback controller can maintain the ammonia concentration within an acceptable error range. This section considers different methods for implementing ammonia feedforward control, and the resulting control authority of the proposed control strategies. Essentially, there are two ways to use an ammonia measurement for feedforward control in an effort to maintain an effluent ammonia setpoint through aeration: (1) by changing the aeration intensity (e.g., varying the dissolved oxygen setpoint or direct ammonia control), or (2) by adding more aerated volume (e.g., switching on aeration in a swing zone). The first option is called aeration intensity control and the second option is called aerated volume control. Aeration intensity control (first option) has both downsides and potential benefits. A major downside of ammonia feedforward aeration intensity control is often its limited control authority. This is different from controlling, for example, denitrification by adding external carbon where the denitrification is essentially directly linked to carbon addition. With ammonia aeration intensity control, increasing aeration to account for increased loading may help, however the nitrification capacity may be limited by the concentration of nitrifiers. The potential benefit of an ammonia feedforward aeration intensity controller is mainly the ability to increase aeration sooner than a feedback controller, and therefore anticipate the impact of a sudden load disturbance. This is achieved in one of two ways: (1) by lowering the ammonia concentration in the reactor to a minimum to provide dilution for the arriving ammonia peak, or (2) by raising the air flow in anticipation of increased oxygen demand. In situations where the ammonia load is low, an ammonia dissolved oxygen controller has a direct impact on the nitrification rate (high control authority). However, the savings potential when the ammonia load is low can likely be addressed by using a feedback ammonia controller. This minimizes the risk of violating effluent ammonia permits as a result of insufficient aeration, because the target variable is measured (feedback) and not predicted (feedforward). Aerated volume control (second option) is a more advantageous control strategy. An ammonia volume controller provides a higher control authority for situations in which the incoming ammonia load is greater than the nitrification capacity of the typically aerated reactors. By switching on aeration in swing zones, this controller can increase the mass of active nitrifiers. Therefore, this controller is better suited for accommodating peak loads. An additional ammonia feedback dissolved oxygen controller will address low loading situations. This control strategy is more beneficial because the two loading situations are managed by two independent control loops with high control authority for each specific situation. Special Cases for Ammonia Feedforward Control. Feedforward ammonia control can be useful in locations (e.g., Germany) where peak effluent limits apply; that is, where plants are permitted based on grab samples with a never-to-exceed limit. Another example would be where extreme influent ammonia peaks occur. However, before setting up a controller, a first step would be to identify the cause of the peak, and attempt to reduce the peak through operational changes, equalization, or pretreatment at industrial sites. To summarize the discussion on feedforward control, special attention should be given to the control authority of a feedforward controller (see Nansemond WRRF case study below). Conventional biological nurient removal plants often have long retention times and therefore slow response times for ammonia. Feedforward control may have benefits for systems January

8 Figure 8 Comparison of ammonia concentrations in last aerated reactor for Strategies 2b (NH 4 feedback control) and 4 (NH 4 feedforward plus feedback control) at 12 8C. Figure 7 Comparison of dissolved oxygen (DO) levels for Strategies 2b (NH 4 feedback control) and 4 (NH 4 feedforward plus feedback control) at 12, 20, and 30 8C. with a short hydraulic retention time (e.g., membrane bioreactors). Plants with ammonia controlled swing zones have a higher control authority to address ammonia peaks. However, care should be taken when tuning the different control loops to avoid the creation of sudden jumps or drops in the ammonia concentration by the feedforward volume ammonia controller at the sensor location of the feedback control loop. These jumps or drops could lead to a delay in the detection of sudden peaks by the feedback controller, resulting in even higher ammonia effluent peaks (Brischke et al., 2010). Designing Ammonia-Based Aeration Control. Designing ammonia-based aeration control strategies is a complex task and requires involvement of various experts from different disciplines. Figure 5 shows a schematic view of the various phases for planning, implementing, and operating advanced aeration control systems. The design requires knowledge of detailed information about the treatment plant under study. A significant effort should be made to fully understand the plant, and all required details and constraints should be taken into account. Although a control strategy can be designed, implemented, and tuned without a model, the use of a dynamic simulator in the design process is strongly recommended. A dynamic plant model can combine the different fields of expertise (e.g., process, instrumentation, control, and operation), and allows off-line testing of various control strategies without the need for a timeconsuming pilot, or full-scale testing. When evaluating different ammonia control strategies, the model can provide valuable results to assess the needs for feedforward control, or determine whether feedback control would be sufficient. It is essential to have a quantifiable understanding of the desired objectives for implementing advanced control. It is often helpful to begin the time-consuming process of instrument testing early in the process because the operators need time to develop confidence in the sensors; some sensors may not be the ideal choice for the location or the planned control strategy. In the design phase, regular interaction between control system designers, process engineers, plant personnel, and others involved is important for a tailored control system. A dynamic model can provide a common language in this process. Aspects which should not be underestimated are operator training, and developing an incentive system for plant personnel (Rieger and Olsson, 2012). Case Study Nansemond WRRF. The Nansemond WRRF has undergone a major upgrade of its treatment capacity, modifying it from a three-stage VIP process (Virginia Initiative Process) to a five-stage Bardenpho process configuration to fulfill more rigorous effluent requirements. The plant is a m 3 /d (114 ML/d) facility currently operating at approximately m 3 /d (61 ML/d) (basis of modeling) with a relatively large geographic collection system and an industrial contribution of approximately 20 percent. An extensive simulation project has been performed to identify optimal aeration control strategies that reduce aeration energy, and optimize the dosage of external carbon (Rieger et al., 2012b). The Nansemond plant utilizes anaerobic digestion, centrate equalization, and centrate treatment by the Ostara struvite recovery process. The basis for plant modeling was anaerobic digestion and full centrate equalization. Figure 6 presents the plant model configuration that was used in the simulation project. One objective was to analyze the need for, and the potential benefits of ammonia feedforward control. Table 3 lists some of the control strategies tested. Each strategy was evaluated for temperatures of 12, 20, and 30 8C, and involved simulating plant performance subject to typical influent flow and load variations over one week. Additional information on the control scenarios can be found in Rieger et al. (2012b). Control Authority of Aeration Intensity Controller. The purpose of a feedforward control strategy with the potential to reduce effluent ammonia peaks is to increase aeration intensity by increasing dissolved oxygen setpoints when the incoming ammonia load is higher than a predicted nitrification capacity. The method used by the feedforward model to estimate the nitrification capacity is described in Rieger et al. (2012a). As shown in Figure 7, ammonia feedforward aeration intensity control (Strategy 4) was only active at very low temperatures (12 8C), although it was inactive at temperature scenarios of 70 Water Environment Research, Volume 86, Number 1

9 Figure 9 Artificial total Kjeldahl nitrogen (TKN) influent peak on top of normal influent pattern. 20 and 30 8C. When active, the ammonia feedforward controller had a very limited impact on effluent concentrations under normal load conditions with a peak reduction of less than 0.1 mgn/l (Figure 8). Because only minimal data on diurnal ammonia influent variations and potential peak loads were available, an artificial ammonia peak as a worst case scenario was created to analyze the feedforward controller performance (Figure 9). Figure 10 shows the results comparing the effluent concentrations for Strategies 2b (NH 4 feedback) and 4 (NH 4 feedforward plus feedback changing dissolved oxygen setpoint). The feedforward controller only achieved limited control authority over ammonia peak loadings; the difference between the resulting ammonia effluent concentrations was less than 0.5 mg/l. Control Authority of Aerated Volume Controller. A second feedforward control strategy with improved control authority to reduce effluent ammonia peaks is to switch on aeration in a swing zone when the incoming ammonia load is higher than a predicted nitrification capacity (i.e., aerated volume control). Details of the feedforward model are described in Rieger et al. (2012a). Switching on aeration in swing zones increases the aerated SRT, and consequently increases the mass of active nitrifiers in the system. Figure 11 shows the dissolved oxygen concentration at the end of the aeration tank for Strategies 2b and 4. The dissolved oxygen concentration in Swing zone AAA_C is shown for Strategy 5 (NH 4 feedforward volume control plus NH 4 feedback dissolved oxygen control). It is evident that aeration is switched on in the swing zones when the predicted nitrification capacity is below the measured incoming ammonia load. Figure 12 compares the ammonia concentrations Figure 11 Comparison of different ammonia-based control strategies at 12 8C (FB ¼ feedback; FF ¼ feedforward; DO ¼ dissolved oxygen). in the last zone of the aeration tanks; Figure 13 shows the same for the effluent. At this point, the feedforward controller has sufficient control authority to maintain the ammonia concentration below 2 mg N/L in the last aerated tank, including situations of high loading. The effluent ammonia concentrations for Strategy 5 are constant at approximately 0.4 mg N/L. Strategy 4 has minimal impact on effluent ammonia concentrations as compared to Strategy 2b, which has only a feedback controller. Figure 14 shows a comparison of energy consumption and Figure 15 shows the carbon dosage for the four control strategies. The difference in aeration costs between the two feedforward strategies is marginal. However, Strategy 5 shows a methanol demand that is approximately 510 L/d greater than for Strategy 4. This is because of the reduced pre-anoxic zone, and consequently, lesser use of influent carbon. Assuming a cost of $5.70 per liter, this results in an annual difference of $ Additional information on influent loads and plant operation is provided in Rieger et al. (2012b). Conclusions Aeration control based on ammonia measurement is applied for one of two reasons: (1) Aeration control may be used to limit aeration to reduce operating costs, and potentially improve performance. The approach is used to partially limit nitrification while maintaining a target effluent ammonia concentration below the permit value. The potential benefits include energy savings, increased denitrification, reduced external carbon dosage, and improved bio-p performance. Manipulating Figure 10 Comparison of ammonia and dissolved oxygen (DO) concentrations at end of aerated zones (Aer4-7_fg) when subject to (artificial) ammonia peak for Strategies 2b (NH 4 feedback control) and 4 (NH 4 feedforward plus feedback control) at 12 8C. Figure 12 Ammonia concentrations at end of aerated zones (Aer4-7_fg) for Strategies 2b, 4, and 5 at 12 8C (FB ¼ feedback; FF ¼ feedforward; DO ¼ dissolved oxygen). January

10 Figure 13 Ammonia in effluent for Strategies 2b, 4, and 5 at 12 8C (FB ¼ feedback; FF ¼ feedforward; DO ¼ dissolved oxygen). aeration intensity has a high control authority to limit nitrification by reducing dissolved oxygen levels, although does not increase nitrification capacity when dissolved oxygen exceeds approximately 1.5 mg/l. (2) Aeration control may be used to manipulate aeration to reduce effluent ammonia peaks. Two approaches were evaluated in this study: (i) controlling aeration intensity, and (ii) adjusting aerated volume fraction. The mass of nitrifiers depends on the average ammonia load removed and the SRT, and changes slowly from day to day. At peak load times, the nitrification capacity of the system may be exceeded, resulting in an effluent ammonia breakthrough. This is a kinetic constraint and cannot be addressed by increased aeration intensity. The only option for an immediate improvement in the reduction of ammonia effluent peaks by nitrification is to increase the active nitrifier mass. This can be achieved by switching on aeration in swing zones, or dosing stored nitrifiers (Yuan et al., 2000). However, the latter would require additional reactor volume. Ammonia-based aeration control for both objectives can be implemented using either feedback or feedforward control. In general, if the same control objective can be achieved by either method, feedback control is preferred because: (1) fewer sensors are required, (2) development of a process model is unnecessary, and (3) feedback control is more robust. An ammonia feedforward control strategy requires at least two ammonia probes (one upstream and one downstream), one dissolved oxygen probe, and a flow meter. To increase accuracy of the model, additional sensors for temperature and mixed liquor suspended solids should be integrated. This results in a significant investment and increased operation and maintenance costs as compared to feedback control. The paper demonstrates that the objective of adjusting aeration intensity to limit nitrification can usually be achieved Figure 14 Energy costs for Strategies 1, 2b, 4, and 5 at 12 8C. Figure 15 Methanol dosage for Strategies 1, 2b, 4, and 5 at 12 8C. using feedback control, suggesting that feedback control is the more suitable approach. Typically, the ammonia concentration in the effluent varies slowly; feedforward control rarely provides additional advantages. A current perception is that feedforward control is beneficial for reducing effluent ammonia peaks. This is based on the belief that feedforward control will provide an early warning of an influent load increase, and aeration intensity can then be increased to avoid an effluent peak in ammonia. However, as previously discussed, the peaks generally result from a kinetic constraint as a result of the limited nitrifier mass, and increasing dissolved oxygen in aerated zones likely will not help. Essentially, the only means for rapidly responding to influent loading peaks and reducing ammonia breakthrough is to increase the mass of active nitrifiers (e.g., by switching on aeration in swing zones or dosing stored nitrifying sludge). Switching aeration on and off in swing zones can possibly be implemented using the simpler feedback control approach, and should not be discounted. However, this may be the one situation in which feedforward control offers benefits. When feedforward control can be justified (e.g., when regular peaks occur which cannot be equalized or in the case of neverto-exceed effluent limits), the selected control strategy should be tested to assess the ability to reduce effluent ammonia peaks. Careful analysis should be applied to determine whether feedforward control offers any benefit over standard feedback control. The case study of Nansemond WRRF showed that feedforward control was only active at very low temperatures. In addition, the feedforward aeration intensity control provided minimal control authority; therefore, the additional costs would significantly reduce potential savings as compared to feedback ammonia control. Whenever process control strategies are to be implemented, dynamic simulation is an excellent tool for testing, and allows a tailored design for a specific plant. Submitted for publication December 4, 2012; accepted for publication April 15, References Åmand, L.; Olsson, G.; Carlsson, B. (2013) Aeration Control A Review. Water Sci. Technol., 67, Ayesa, E.; De la Sota, A.; Grau, P.; Sagarna, J. M.; Salterain, A.; Suescun, J. (2006) Supervisory Control Strategies for the New WWTP of Galindo-Bilbao: The Long Run from the Conceptual Design to the Full-Scale Experimental Validation. Water Sci. Technol., 53 (4 5), Brischke, K.; Olds, K.; Adams, D.; Hardison, J.; Rieger, L. (2010) Using Whey as a Supplemental Carbon Source Under Real Time Control 72 Water Environment Research, Volume 86, Number 1

11 Conditions Or a Story of Turds and Whey. Proceedings of the 83 rd Annual Water Environment Federation Technical Exposition and Conference [CD-ROM]; New Orleans, Louisiana, Oct 2 6; Water Environment Federation: Alexandria, Virginia. Devisscher, M.; Ciacci, G.; Fé, L.; Benedetti, L.; Bixio, D.; Thoeye, C.; De Gueldre, G.; Marsili-Libelli, S.; Vanrolleghem, P. A. (2006) Estimating Costs and Benefits of Advanced Control for Wastewater Treatment Plants The MAgIC Methodology. Water Sci. Technol., 53 (4 5), Gujer, W.; Erni, P. (1978) The Effect of Diurnal Ammonium Load Variation on the Performance of Nitrifying Activated Sludge Processes. Prog. Water Technol., 10 (5 6), Houweling, D.; Wunderlin, P.; Dold, P.; Bye, C.; Joss, A.; Siegrist, H. (2011) N 2 O Emissions: Modeling the Effect of Process Configuration and Diurnal Loading Patterns. Water Environ. Res., 83, Husmann, M.; Orth, H.; Schlegel, S.; Teichgräber, B. (1998) Application of Process Control for Improved Nitrogen Removal. Water Sci. Technol., 38 (3), Ingildsen, P.; Jeppsson, U.; Olsson, G. (2002) Dissolved Oxygen Controller Based on On-Line Measurements of Ammonium Combining Feed-Forward and Feedback. Water Sci. Technol., 45 (4 5), Jimenez, J.; Dursun, D.; Dold, P.; Bratby, J.; Keller, J.; Parker, D. (2010) Simultaneous Nitrification-Denitrification to Meet Low Effluent Nitrogen Limits: Modeling, Performance and Reliability. Proceedings of the 83 rd Annual Water Environment Federation Technical Exposition and Conference [CD-ROM]; New Orleans, Louisiana, Oct 2 6; Water Environment Federation: Alexandria, Virginia. Kitamura, K.; Nemoto, T.; Matsushita, S.; Uchida, M.; Yoda, Y.; Kassai, K.; Hamamoto, A.; Satoh, K. (2012) Discussion about Cause of Nitrous Oxide (N 2 O) Emission in Wastewater Treatment Plant, Based on Long-Term Continuous Measurement. Proceedings of the 85 th Annual Water Environment Federation Technical Exposition and Conference [CD-ROM]; New Orleans, Louisiana, Sept 29 Oct 3; Water Environment Federation: Alexandria, Virginia. Krhutkovaì, O.; Novaìk, L.; Pachmanovaì, L.; Benaìkovaì, A.; Wanner, J.; Kos, M. (2006) In Situ Bioaugmentation of Nitrification in the Regeneration Zone: Practical Application and Experiences at Full- Scale Plants. Water Sci. Technol., 53 (12), Lemaire, R.; Chauzy, J.; Veuillet, F.; DiMassimo, R.; Sorensen, K.; Deleris, S. (2011) Advanced Control System to Reduce N 2 O Emission and Improve Performance of an SBR Treating N-Rich Effluent Via Nitrite Pathway. Proceedings of the 84 th Annual Water Environment Federation Technical Exposition and Conference [CD-ROM]; Los Angeles, California, Oct 15 19; Water Environment Federation: Alexandria, Virginia. Liu, W.; Lee, G. J. F.; Schloth, P. E.; Serra, M. E. (2005). Side by Side Comparison Demonstrated a 36% Increase of Nitrogen Removal and 19% Reduction of Aeration Requirements Using a Feed Forward Online Optimization System. Proceedings of the 78 th Annual Water Environment Federation Technical Exposition and Conference [CD-ROM]; Washington, D.C., Oct 29 Nov 2; Water Environment Federation: Alexandria, Virginia. Marcelino, M.; Wallaert, D.; Guisasola, A.; Baeza, J. A. (2011) A Two- Sludge System for Simultaneous Biological C, N and P Removal Via the Nitrite Pathway. Water Sci. Technol., 64, Martins, A. M. P.; Pagilla, K.; Heijnen, J. J.; van Loosdrecht, M. C. M. (2004) Filamentous Bulking Sludge A Critical Review. Water Res., 38, Münch, E. V.; Lant, P.; Keller, J. (1996) Simultaneous Nitrification and Denitrification in Bench-Scale Sequencing Batch Reactors. Water Res., 30 (2), Nielsen, M. K.; Önnerth, T. B. (1995) Improvement of a Recirculating Plant by Introducing STAR Control. Water Sci. Technol., 31 (2), Olsson, G.; Newell, B. (1999) Wastewater Treatment Systems: Modelling, Diagnosis and Control. IWA Publishing: London. Rieger, L.; Olsson, G. (2012) Why Many Control Systems Fail. Water Environ. Technol., 24 (6), Rieger, L.; Takács, I.; Siegrist, H. (2012a) Improving Nutrient Removal While Reducing Energy Use at Three Swiss WWTPs Using Advanced Control. Water Environ. Res., 84 (2), Rieger, L.; Bott, C. B.; Balzer, W. J.; Jones, R. M. (2012b) Model-Based Aeration System Design Case Study Nansemond WWTP. Proceedings of the 85 th Annual Water Environment Federation Technical Exposition and Conference [CD-ROM]; New Orleans, Louisiana, Sept 29 Oct 3; Water Environment Federation: Alexandria, Virginia. Salem, S.; Berends, D.; Heijnen, J. J.; van Loosdrecht, M. C. M. (2002) Model-Based Evaluation of a New Upgrading Concept for N- Removal. Water Sci. Technol., 45 (6), Shen, T.; Shi, H.; Shi, H.; Jing, H.; Xiong, H. (2011) Feedforward Control for Nitrogen Removal in a Pilot-Scale Anaerobic-Anoxic-Oxic Plant for Municipal Wastewater Treatment. Front. Environ. Sci. Engin. China, 5, Sunner, N.; Haeck, M.; Thornton, A. (2009) Evaluation of a Full-Scale Activated Sludge Real Time Control System. Proceedings of the 82 nd Annual Water Environment Federation Technical Exposition and Conference [CD-ROM]; Orlando, Florida, Oct 17 21; Water Environment Federation: Alexandria, Virginia. Vrečko, D.; Hvala, N.; Stražar, M. (2011) The Application of Model Predictive Control of Ammonia Nitrogen in an Activated Sludge Process. Water Sci. Technol., 64, Walz, T.; Coughenour, J. R.; Williams, K.; Jacobs, J.; Shone, L.; Stahl, T.; Kestel, S.; Palmer, D. (2009) Energy Savings at Phoenix 23 rd Avenue Wastewater Treatment Plant Using Feed-Forward Process Control. Proceedings of the 82 nd Annual Water Environment Federation Technical Exposition and Conference [CD-ROM]; Orlando, Florida, Oct 17 21; Water Environment Federation: Alexandria, Virginia. Yong, M.; Yongzhen, P.; Shuying, W. (2005) Feedforward-Feedback Control of Dissolved Oxygen Concentration in a Predenitrification System. Bioprocess Biosyst. Eng., 27, Yuan, Z.; Bogaert, H.; Vansteenkiste, G.; Verstraete, W. (1998) Sludge Storage for Countering Ammonia Shock Loads and Toxicity Incidents. Water Sci. Technol., 37 (12), Yuan, Z.; Bogaert, H.; Leten, J.; Verstraete, W. (2000) Reducing the Size of a Nitrogen Removal Activated Sludge Plant by Shortening the Retention Time of Inert Solids Via Sludge Storage. Water Res., 34 (2), January

ENHANCED BIOLOGICAL PHOSPHORUS REMOVAL WITHIN MEMBRANE BIOREACTORS. 255 Consumers Road Toronto, ON, Canada, M2J 5B6

ENHANCED BIOLOGICAL PHOSPHORUS REMOVAL WITHIN MEMBRANE BIOREACTORS. 255 Consumers Road Toronto, ON, Canada, M2J 5B6 ENHANCED BIOLOGICAL PHOSPHORUS REMOVAL WITHIN MEMBRANE BIOREACTORS G. Crawford 1,2, G. Daigger 1, and Z. Erdal 1 1 CH2M HILL 2 CH2M HILL 255 Consumers Road Toronto, ON, Canada, M2J 5B6 ABSTRACT Several

More information

MODEL-BASED AERATION SYSTEMS DESIGN - CASE STUDY NANSEMOND WWTP

MODEL-BASED AERATION SYSTEMS DESIGN - CASE STUDY NANSEMOND WWTP MODEL-BASED AERATION SYSTEMS DESIGN - CASE STUDY NANSEMOND WWTP Leiv Rieger 1*, Charles B. Bott 2, William J. Balzer 2 and Richard M. Jones 1 1 EnviroSim Associates Ltd., Hamilton, Ontario, Canada. 2 HRSD

More information

Evaluation of Different Nitrogen Control Strategies for a Combined Pre- and Post-Denitrification Plant

Evaluation of Different Nitrogen Control Strategies for a Combined Pre- and Post-Denitrification Plant Proceedings of e 7 World Congress The International Federation of Automatic Control Evaluation of Different Nitrogen Control Strategies for a Combined Pre- and Post-Denitrification Plant A. Stare, N. Hvala,

More information

The following biological nutrient removal processes were evaluated in detail in the 2016 Liquid Processing Facilities Plan:

The following biological nutrient removal processes were evaluated in detail in the 2016 Liquid Processing Facilities Plan: Nitrite Shunt Pilot Project Purpose: The purpose of this project is to full scale pilot test the nitrite shunt biological nutrient removal process to confirm process design criteria, impacts to sludge

More information

Feedforward-feedback control of dissolved oxygen concentration in a predenitrification system

Feedforward-feedback control of dissolved oxygen concentration in a predenitrification system Bioprocess Biosyst Eng (2005) 27: 223 228 DOI 10.1007/s00449-004-0390-0 ORIGINAL PAPERS Ma Yong Æ Peng Yongzhen Æ Wang Shuying Feedforward-feedback control of dissolved oxygen concentration in a predenitrification

More information

CSR Process Simulations Can Help Municipalities Meet Stringent Nutrient Removal Requirements

CSR Process Simulations Can Help Municipalities Meet Stringent Nutrient Removal Requirements CSR Process Simulations Can Help Municipalities Meet Stringent Nutrient Removal Requirements Continuous Flow Sequencing Reactor (CSR) Basin with Moving Bridge, Submerged Diffusers, and Stationary Diffusers

More information

Presentation Outline

Presentation Outline Presentation Outline Nitrification/denitrification refresher Treatment technologies available for nitrification and BNR/ENR What is the problem? BNR/ENR VPDES permitting Causes of reduced BNR performance

More information

ENHANCING THE PERFORMANCE OF OXIDATION DITCHES. Larry W. Moore, Ph.D., P.E., DEE Professor of Environmental Engineering The University of Memphis

ENHANCING THE PERFORMANCE OF OXIDATION DITCHES. Larry W. Moore, Ph.D., P.E., DEE Professor of Environmental Engineering The University of Memphis ENHANCING THE PERFORMANCE OF OXIDATION DITCHES Larry W. Moore, Ph.D., P.E., DEE Professor of Environmental Engineering The University of Memphis ABSTRACT Oxidation ditches are very popular wastewater treatment

More information

SIMPLE and FLEXIBLE ENERGY SAVINGS And PERFORMANCE ENHANCEMENT for OXIDATION DITCH UPGRADES

SIMPLE and FLEXIBLE ENERGY SAVINGS And PERFORMANCE ENHANCEMENT for OXIDATION DITCH UPGRADES SIMPLE and FLEXIBLE ENERGY SAVINGS And PERFORMANCE ENHANCEMENT for OXIDATION DITCH UPGRADES Oxidation ditches are very popular wastewater treatment processes for small to medium sized municipalities that

More information

COMPARISON OF SBR AND CONTINUOUS FLOW ACTIVATED SLUDGE FOR NUTRIENT REMOVAL

COMPARISON OF SBR AND CONTINUOUS FLOW ACTIVATED SLUDGE FOR NUTRIENT REMOVAL COMPARISON OF SBR AND CONTINUOUS FLOW ACTIVATED SLUDGE FOR NUTRIENT REMOVAL Alvin C. Firmin CDM Jefferson Mill, 670 North Commercial Street Suite 201 Manchester, New Hampshire 03101 ABSTRACT Sequencing

More information

1/22/2013. Low Energy Process Control

1/22/2013. Low Energy Process Control Low Energy Process Control January 23 rd, 213 1 WEF Webcast Low Energy Process Control Ammonia based aeration control Leiv RIEGER, inctrl Solutions Inc., Canada Acknowledgement Peter L. Dold, EnviroSim

More information

CRUDE COD CHARACTERISTICS SIGNIFICANT FOR BIOLOGICAL P REMOVAL: A U.K. EXAMPLE

CRUDE COD CHARACTERISTICS SIGNIFICANT FOR BIOLOGICAL P REMOVAL: A U.K. EXAMPLE CRUDE COD CHARACTERISTICS SIGNIFICANT FOR BIOLOGICAL P REMOVAL: A U.K. EXAMPLE Jarvis, S. 1, Burger, G. 2, Du, W. 2, Bye, C. 2 and Dold, P. 2 1 Thames Water Utilities Ltd., 2 EnviroSim Associates Ltd.

More information

Sensors for Activated Sludge Aeration Control

Sensors for Activated Sludge Aeration Control October 23, 2012 Use of Ammonia and Nitrate Sensors for Activated Sludge Aeration Control Troy Morgan; Western Regional Process Analytical Manager Overview Sensors Available Optical - Nitrate / Nitrite

More information

Integrated real-time SRT and aeration control in the city of Grand Rapids

Integrated real-time SRT and aeration control in the city of Grand Rapids 2016 MWEA 92 st Annual Conference Sunday, June 18 th - Wednesday, June 21 st Boyne Mountain Resort Integrated real-time SRT and aeration control in the city of Grand Rapids M. Lunn, City of Grand Rapids

More information

Contents General Information Abbreviations and Acronyms Chapter 1 Wastewater Treatment and the Development of Activated Sludge

Contents General Information Abbreviations and Acronyms Chapter 1 Wastewater Treatment and the Development of Activated Sludge Contents Contents General Information Abbreviations and Acronyms... 6 Chapter 1 Wastewater Treatment and the Development of Activated Sludge... 8 The Importance of Wastewater Treatment... 8 The Scope of

More information

FIRST APPLICATION OF THE BABE PROCESS AT S-HERTOGENBOSCH WWTP. Pettelaarpark 70, PO Box GA, s-hertogenbosch, The Netherlands

FIRST APPLICATION OF THE BABE PROCESS AT S-HERTOGENBOSCH WWTP. Pettelaarpark 70, PO Box GA, s-hertogenbosch, The Netherlands FIRST APPLICATION OF THE BABE PROCESS AT S-HERTOGENBOSCH WWTP Bastiaan Hommel 1, Eric van der Zandt 2, Debby Berends 2, Victor Claessen 1 1 Dutch Water Authority Aa en Maas Pettelaarpark 70, PO Box 5049

More information

At the Mercy of the Process Impacts of Nitrogen Removal Performance on WWTP Disinfection

At the Mercy of the Process Impacts of Nitrogen Removal Performance on WWTP Disinfection OBG PRESENTS: At the Mercy of the Process Impacts of Nitrogen Removal Performance on WWTP Disinfection Ned Talbot, PE Tri-Association Conference 2018 8/30/18 9:00-9:30AM AGENDA Overview of Plant Processes

More information

CTB3365x Introduction to Water Treatment

CTB3365x Introduction to Water Treatment CTB3365x Introduction to Water Treatment W5a2 Nitrogen removal Merle de Kreuk If you already watched the movie about the nitrogen cycle, you understand that with introduction of the Haber-Bosch process,

More information

AMPC Wastewater Management Fact Sheet Series Page 1

AMPC Wastewater Management Fact Sheet Series Page 1 Nitrogen removal Nitrogen present in meat processing wastewater are termed a nutrient, since they are essential elements for life. They largely derive from proteins dissolved into wastewater from meat

More information

AMPC Wastewater Management Fact Sheet Series Page 1

AMPC Wastewater Management Fact Sheet Series Page 1 Nitrogen removal Nitrogen present in meat processing wastewater are termed a nutrient, since they are essential elements for life. They largely derive from proteins dissolved into wastewater from meat

More information

New Developments in BioWin 4.0

New Developments in BioWin 4.0 New Developments in BioWin 4.0 BioWin 4.0 continues to expand the capabilities of wastewater treatment plant simulation with key enhancements to the core model, the model library, and the interface. A

More information

CE421/521 Environmental Biotechnology. Nitrogen and Phosphorus Cycles Lecture Tim Ellis

CE421/521 Environmental Biotechnology. Nitrogen and Phosphorus Cycles Lecture Tim Ellis CE421/521 Environmental Biotechnology Nitrogen and Phosphorus Cycles Lecture 9-269 26-06 Tim Ellis Nitrification Kinetics µ = µ K maxs NH 4 S + S NH4 K O S O2 + S O2 where µ max = maximum specific growth

More information

An Innovative Approach to Retrofitting for Nitrogen Removal

An Innovative Approach to Retrofitting for Nitrogen Removal June 29, 2017 An Innovative Approach to Retrofitting for Nitrogen Removal OWEA 2017 TECHNICAL CONFERENCE & EXPO Innovation From Wikipedia: The application of better solutions that meet new requirements.

More information

Secondary Treatment Process Control

Secondary Treatment Process Control SARBS One-Day Training Seminar Phoenix Club, Anaheim Secondary Treatment Process Control Graham Juby June 5, 2013 Objectives Provide an understanding of nitrogen removal process interactions to support

More information

NITROGEN REMOVAL GRANT WEAVER, PE & WWTP OPERATOR PRESIDENT THE WATER PLANET COMPANY. Create Optimal Habitats

NITROGEN REMOVAL GRANT WEAVER, PE & WWTP OPERATOR PRESIDENT THE WATER PLANET COMPANY.   Create Optimal Habitats NITROGEN REMOVAL Create Optimal Habitats Recognize the Importance of People Skills Full-scale Experimentation GRANT WEAVER, PE & WWTP OPERATOR Regulatory Support Utility Support PRESIDENT THE WATER PLANET

More information

Nutrient Removal Optimization at the Fairview WWTP

Nutrient Removal Optimization at the Fairview WWTP Alyssa Mayer, PE Principal Engineer Nutrient Removal Optimization at the Fairview WWTP Mark Strahota, PE Associate Presentation Overview Project Background Process Model Development BNR Design Considerations

More information

Innovations in Nitrogen and Phosphorus Removal

Innovations in Nitrogen and Phosphorus Removal 1 st Annual Innovative Wastewater Technologies Seminar Innovations in Nitrogen and Phosphorus Removal Jose A. Jimenez, Ph.D., P.E. Director of Technology and Innovation Brown and Caldwell July 15 th, 2015

More information

General Operational Considerations in Nutrient and Wet Weather Flow Management for Wastewater Treatment Facilities Part II

General Operational Considerations in Nutrient and Wet Weather Flow Management for Wastewater Treatment Facilities Part II General Operational Considerations in Nutrient and Wet Weather Flow Management for Wastewater Treatment Facilities Part II Samuel Jeyanayagam, PhD, PE, BCEE Julian Sandino, PhD, PE, BCEE Ohio WEA Plant

More information

General Information on Nitrogen

General Information on Nitrogen General Information on Nitrogen What is nitrogen? Nitrogen was discovered in 1772 by Daniel Rutherford in Scotland Nitrogen gas makes up nearly 80% of the air we breathe Nitrogen gas is not toxic Nitrogen

More information

USING NUMERICAL SIMULATION SOFTWARE FOR IMPROVING WASTEWATER TREATMENT EFFICIENCY

USING NUMERICAL SIMULATION SOFTWARE FOR IMPROVING WASTEWATER TREATMENT EFFICIENCY USING NUMERICAL SIMULATION SOFTWARE FOR IMPROVING WASTEWATER TREATMENT EFFICIENCY Catalina Raluca Mocanu, Lacramioara Diana Robescu University Politehnica of Bucharest, Spl. Independentei, nr. 313, sector

More information

Improving Nutrient Removal While Reducing Energy Use at Three Swiss WWTPs Using Advanced Control

Improving Nutrient Removal While Reducing Energy Use at Three Swiss WWTPs Using Advanced Control Improving Nutrient Removal While Reducing Energy Use at Three Swiss WWTPs Using Advanced Control Leiv Rieger 1,2 *, Imre Takács 3, Hansruedi Siegrist 1 ABSTRACT: Aeration consumes about 60% of the total

More information

Advances in Nitrogen and Phosphorus Removal at Low DO Conditions

Advances in Nitrogen and Phosphorus Removal at Low DO Conditions Advances in Nitrogen and Phosphorus Removal at Low DO Conditions Pusker Regmi Vail Operator Training Seminar 13 October, 2016 Wastewater Treatment and Energy The water quality industry is currently facing

More information

Environmental Biotechnology Cooperative Research Centre Date submitted: March 2008 Date published: March 2011

Environmental Biotechnology Cooperative Research Centre Date submitted: March 2008 Date published: March 2011 final report Project code: A.ENV.0044 Prepared by: Environmental Biotechnology Cooperative Research Centre Date submitted: March 2008 Date published: March 2011 PUBLISHED BY Meat & Livestock Australia

More information

Removal of High C and N Contents in Synthetic Wastewater Using Internal Circulation of Anaerobic and Anoxic/Oxic Activated Sludge Processes

Removal of High C and N Contents in Synthetic Wastewater Using Internal Circulation of Anaerobic and Anoxic/Oxic Activated Sludge Processes Removal of High C and N Contents in Synthetic Wastewater Using Internal Circulation of Anaerobic and Anoxic/Oxic Activated Sludge Processes Nittaya Boontian School of Environmental Engineering, Institute

More information

WASTEWATER TREATMENT PLANT OPTIMIZATION USING A DYNAMIC MODEL APPROACH

WASTEWATER TREATMENT PLANT OPTIMIZATION USING A DYNAMIC MODEL APPROACH 370 Sixth International Water Technology Conference, IWTC 2001, Alexandria, Egypt WASTEWATER TREATMENT PLANT OPTIMIZATION USING A DYNAMIC MODEL APPROACH Marc-André Desjardins 1 *, Gino Bélanger 1, Diaa

More information

A Critical New Look at Nutrient Removal Processes

A Critical New Look at Nutrient Removal Processes A Critical New Look at Nutrient Removal Processes Thomas E. Wilson,* John McGettigan* *Earth Tech, Inc. 675 North Washington Street Alexandria, Virginia 22314 ABSTRACT This paper questions the basic practice

More information

Module 17: The Activated Sludge Process - Part III Answer Key

Module 17: The Activated Sludge Process - Part III Answer Key Module 17: The Activated Sludge Process - Part III Answer Key What other differences can you see between Complete Mix and Step Aeration? One of the features that make Complete Mix Aeration different from

More information

Energy Reduction and Nutrient Removal in WWTPs Using Feed- Forward Process Control

Energy Reduction and Nutrient Removal in WWTPs Using Feed- Forward Process Control Energy Reduction and Nutrient Removal in WWTPs Using Feed- Forward Process Control Tilo Stahl, Ph.D. 1 *, George Lee 1, Matthew Gray 1, P.E, Steven Kestel 1 1 BioChem Technology, Inc., King of Prussia,

More information

EFFECT OF FERROUS SULPHATE ON THE SIMULTANEOUS ORGANIC MATTER AND NUTRIENT REMOVAL PERFORMANCE OF SEQUENCING BATCH REACTOR

EFFECT OF FERROUS SULPHATE ON THE SIMULTANEOUS ORGANIC MATTER AND NUTRIENT REMOVAL PERFORMANCE OF SEQUENCING BATCH REACTOR EFFECT OF FERROUS SULPHATE ON THE SIMULTANEOUS ORGANIC MATTER AND NUTRIENT REMOVAL PERFORMANCE OF SEQUENCING BATCH REACTOR Engin Gürtekin Department of Environmental Engineering, Firat University, Elazığ,

More information

Choices to Address Filamentous Growth

Choices to Address Filamentous Growth Michigan Water Environment Association Process Seminar November 12, 2015 Choices to Address Filamentous Growth Richard Beardslee City of Battle Creek Nathan Cassity Donohue & Associates Outline Battle

More information

Discussion about Cause of Nitrous Oxide (N 2 O) Emission in Wastewater Treatment Plant, Based on Long-Term Continuous Measurement

Discussion about Cause of Nitrous Oxide (N 2 O) Emission in Wastewater Treatment Plant, Based on Long-Term Continuous Measurement Discussion about Cause of Nitrous Oxide (N 2 O) Emission in Wastewater Treatment Plant, Based on Long-Term Continuous Measurement Tokyo Metropolitan Government, the Bureau of Sewerage Kiyoaki Kitamura

More information

operation of continuous and batch reactors. Contrary to what happens in the batch reactor, the substrate (BOD) of the wastewater in the continuous rea

operation of continuous and batch reactors. Contrary to what happens in the batch reactor, the substrate (BOD) of the wastewater in the continuous rea The Effect of Ammonia Loading on the Nitrification Kinetic of Aerobic Baffled Continuous Biological Reactor S.R.M. Kutty, M.H. Isa and L.C. Leong Abstract - The purpose of this study is to determine the

More information

RE ENGINEERING O&M PRACTICES TO GET NITROGEN & PHOSPHORUS REMOVAL WITHOUT FACILITY UPGRADES

RE ENGINEERING O&M PRACTICES TO GET NITROGEN & PHOSPHORUS REMOVAL WITHOUT FACILITY UPGRADES RE ENGINEERING O&M PRACTICES TO GET NITROGEN & PHOSPHORUS REMOVAL WITHOUT FACILITY UPGRADES GRANT WEAVER, PE & WASTEWATER OPERATOR WISCONSIN WASTEWATER OPERATORS ASSOCIATION WISCONSIN DELLS, WI OCTOBER

More information

Bioprocess Intelligent Operating System -Beyond Ammonia Control-

Bioprocess Intelligent Operating System -Beyond Ammonia Control- Bioprocess Intelligent Operating System -Beyond Ammonia Control- BioChem Technology, Inc. King of Prussia, PA May 20, 2015 Company Milestones 1978 Incorporation of BioChem Technology, Inc. as a pharmaceutical

More information

NEW BIOLOGICAL PHOSPHORUS REMOVAL CONCEPT SUCCESSFULLY APPLIED IN A T-DITCH PROCESS WASTEWATER TREATMENT PLANT

NEW BIOLOGICAL PHOSPHORUS REMOVAL CONCEPT SUCCESSFULLY APPLIED IN A T-DITCH PROCESS WASTEWATER TREATMENT PLANT NEW BIOLOGICAL PHOSPHORUS REMOVAL CONCEPT SUCCESSFULLY APPLIED IN A T-DITCH PROCESS WASTEWATER TREATMENT PLANT ABSTRACT C. Yang*, L. Zhou**, W. Luo***, and L. Johnson**** *Corstar International Corp. 111

More information

A Battle to Be the Best: A Comparison of Two Powerful Sidestream Treatment Technologies: Post Aerobic Digestion and Anammox

A Battle to Be the Best: A Comparison of Two Powerful Sidestream Treatment Technologies: Post Aerobic Digestion and Anammox A Battle to Be the Best: A Comparison of Two Powerful Treatment Technologies: Post Aerobic Digestion and Anammox David Oerke/CH2M Tom Johnson/CH2M Bruce Johnson/CH2M Heidi Bauer/CH2M Steve Graziano/CH2M

More information

IWA Publishing 2012 Water Practice & Technology Vol 7 No 3 doi: /wpt

IWA Publishing 2012 Water Practice & Technology Vol 7 No 3 doi: /wpt IWA Publishing 2012 Water Practice & Technology Vol 7 No 3 Comparison of denitrification-nitrification and step-feed activated sludge processes with dynamic simulation K. Sahlstedt a, H. Haimi b and J.

More information

Wastewater Nitrogen Characteristics, Treatment and Removal Options. Bob Smith, Orenco Systems, Inc. GEC 2013

Wastewater Nitrogen Characteristics, Treatment and Removal Options. Bob Smith, Orenco Systems, Inc. GEC 2013 Wastewater Nitrogen Characteristics, Treatment and Removal Options Bob Smith, Orenco Systems, Inc. GEC 2013 ##/##/#### #1 Nitrogen Nitrogen (N 2 ) in the environment exists primarily in the earth s atmosphere

More information

Aeration Basics the Bug s Eye View

Aeration Basics the Bug s Eye View Aeration Basics the Bug s Eye View Leonard E. Ripley, Ph.D., P.E., BCEE Senior Environmental Engineer Freese and Nichols, Inc. WEAT Electrical & Instrumentation Seminar March 20, 2019 Why Do We Aerate?

More information

Combined Optimization of the Biological Nitrogen Removal in Activated Sludge-Biofilm Wastewater Treatment Systems

Combined Optimization of the Biological Nitrogen Removal in Activated Sludge-Biofilm Wastewater Treatment Systems PhD Thesis Combined Optimization of the Biological Nitrogen Removal in Activated Sludge-Biofilm Wastewater Treatment Systems Gábor Tardy bioengineer, MSc Supervisor: Andrea Jobbágy associate professor

More information

Enhancing activated sludge nitrification through seeding from a downstream nitrifying fixed-film reactor

Enhancing activated sludge nitrification through seeding from a downstream nitrifying fixed-film reactor Ŕ periodica polytechnica Chemical Engineering 1/1 (27) 33 37 doi: 1.3311/pp.ch.27-1.6 web: http:// www.pp.bme.hu/ ch c Periodica Polytechnica 27 Enhancing activated sludge nitrification through seeding

More information

Six years of experience with N 2 O emission from wastewater treatment

Six years of experience with N 2 O emission from wastewater treatment Six years of experience with N 2 O emission from wastewater treatment Eveline I.P. Volcke 1, Matthijs R.J. Daelman 1,2, Kris M. Mampaey 1, Celia M. Castro-Barros 1, Mark C.M. van Loosdrecht 2 1 Department

More information

SECTION 8.0 NEWPCC SECOND PRIORITY CONTROL ALTERNATIVES

SECTION 8.0 NEWPCC SECOND PRIORITY CONTROL ALTERNATIVES SECTION 8.0 NEWPCC SECOND PRIORITY CONTROL ALTERNATIVES 8.1 PREAMBLE Table 8.1 below indicates the target ammonia concentrations for the Best Practicable and the Second Priority Levels of Control for the

More information

Altoona Westerly Wastewater Treatment Facility BNR Conversion with Wet Weather Accommodation

Altoona Westerly Wastewater Treatment Facility BNR Conversion with Wet Weather Accommodation Pennsylvania Water Environment Federation PennTEC Annual Technical Conference June 4, 2013 Altoona Westerly Wastewater Treatment Facility BNR Conversion with Wet Weather Accommodation Presented by: Jim

More information

Probabilistic Modeling of Two-Stage Biological Nitrogen Removal Process: Formulation of Control Strategy for Enhanced Process Certainty

Probabilistic Modeling of Two-Stage Biological Nitrogen Removal Process: Formulation of Control Strategy for Enhanced Process Certainty Probabilistic Modeling of Two-Stage Biological Nitrogen Removal Process: Formulation of Control Strategy for Enhanced Process Certainty By Ayanangshu Dey (Ayan) & B S Magbanua Jr., Ph.D, PE Department

More information

Introducing the Granular Sludge Sequencing Tank

Introducing the Granular Sludge Sequencing Tank BioWin Advantage Volume 7 - Number 2 - March 2018 Introducing the Granular Sludge Sequencing Tank Files : Case 1 1 d Two GSSTs.bwc Case 2 1 d Two GSSTs.bwc Case 3 - Aeration Controller.bcf Case 3A 1 d

More information

Post-Aerobic Digester with Bioaugmentation Pilot Study City of Meridian, ID WWTP PNCWA 2010

Post-Aerobic Digester with Bioaugmentation Pilot Study City of Meridian, ID WWTP PNCWA 2010 Post-Aerobic Digester with Bioaugmentation Pilot Study City of Meridian, ID WWTP by: William Leaf Adrienne Menniti Bruce Johnson CH2M HILL, Inc. Clint Dolsby Tracy Crane City of Meridian October 26, 21

More information

SBR PROCESS FOR WASTEWATER TREATMENT

SBR PROCESS FOR WASTEWATER TREATMENT SBR PROCESS FOR WASTEWATER TREATMENT IMR E&T S.r.l. Maria Vittoria Marra maria.vittoria.marra@imr.it www.imr.it Purification of wastewater A process aimed at removing organic and inorganic contaminants

More information

New Developments in BioWin 5.3

New Developments in BioWin 5.3 New Developments in BioWin 5.3 December 6, 2017 BioWin 5.3 contains a new Granular Sludge Sequencing Tank element to model this process, which is gaining acceptance worldwide as an effective wastewater

More information

Implementation and Results of a Feed-Forward Process Controller

Implementation and Results of a Feed-Forward Process Controller Implementation and Results of a Feed-Forward Process Controller Matthew Gray 1*, Jim McQuarrie 2, Steven Kestel 1, Heather Phillips 3, and Tilo Stahl 1 1 BioChem Technology, King of Prussia, PA 2 Metro

More information

ADVANCED CONTROL SYSTEM OF ACTIVATED SLUDGE PROCESSES USING IN- SITU AMMONIUM AND NITRATE PROBES

ADVANCED CONTROL SYSTEM OF ACTIVATED SLUDGE PROCESSES USING IN- SITU AMMONIUM AND NITRATE PROBES Proceedings of the 4 th International Conference on Environmental Science and Technology Rhodes, Greece, 3-5 September 205 ADVANCED CONTROL SYSTEM OF ACTIVATED SLUDGE PROCESSES USING IN- SITU AMMONIUM

More information

OWEA Annual Technical Conference and Exhibition Upgrading WRFs for Biological Nutrient Removal. June 25, 2015

OWEA Annual Technical Conference and Exhibition Upgrading WRFs for Biological Nutrient Removal. June 25, 2015 OWEA Annual Technical Conference and Exhibition Upgrading WRFs for Biological Nutrient Removal June 25, 2015 Agenda Permitting and Planning BNR Overview Case Example Innovative Approaches Proactive Participation

More information

- 1 - Retrofitting IFAS Systems In Existing Activated Sludge Plants. by Glenn Thesing

- 1 - Retrofitting IFAS Systems In Existing Activated Sludge Plants. by Glenn Thesing - 1 - Retrofitting IFAS Systems In Existing Activated Sludge Plants by Glenn Thesing Through retrofitting IFAS systems, communities can upgrade and expand wastewater treatment without the expense and complication

More information

NITROGEN REMOVAL GUIDE FOR WASTEWATER OPERATORS THE WATER PLANET COMPANY FORMS OF NITROGEN OF INTEREST TO WASTEWATER OPERATORS

NITROGEN REMOVAL GUIDE FOR WASTEWATER OPERATORS THE WATER PLANET COMPANY   FORMS OF NITROGEN OF INTEREST TO WASTEWATER OPERATORS NITROGEN REMOVAL GUIDE FOR WASTEWATER OPERATORS THE WATER PLANET COMPANY www.cleanwaterops.com FORMS OF NITROGEN OF INTEREST TO WASTEWATER OPERATORS Nitrogen exists in several forms. The principal nitrogen

More information

Andrea Nifong, World Water Works (formerly HRSD) Stephanie Klaus, VT & HRSD

Andrea Nifong, World Water Works (formerly HRSD) Stephanie Klaus, VT & HRSD Recommendations and Lessons Learned from the Startup of the First Two Full-Scale Sidestream Deammonification Processes in North America: DEMON and ANITA Mox Andrea Nifong, World Water Works (formerly HRSD)

More information

4-1-1 New Aeration Control System Based on Ammonium Measurements : Effect on Energy Saving and Denitrification in an Aerobic Tank

4-1-1 New Aeration Control System Based on Ammonium Measurements : Effect on Energy Saving and Denitrification in an Aerobic Tank -1-1 New Aeration Control System Based on Ammonium easurements : Effect on Energy Saving and Denitrification in an Aerobic Tank Aki Hamamoto 1*, Kouichi Sato 1, Syungo Aida 2, akoto Shimoike 2 1 Tokyo

More information

Energy efficient process of nitrification and denitrification in activated sludge system with low organic load

Energy efficient process of nitrification and denitrification in activated sludge system with low organic load Energy efficient process of nitrification and denitrification in activated sludge system with low organic load I.A.Gulshin 1,* and E.S Gogina 1 1 Moscow State University of Civil Engineering,, 129337,

More information

BEING GOOD STEWARDS: IMPROVING EFFLUENT QUALITY ON A BARRIER ISLAND. 1.0 Executive Summary

BEING GOOD STEWARDS: IMPROVING EFFLUENT QUALITY ON A BARRIER ISLAND. 1.0 Executive Summary BEING GOOD STEWARDS: IMPROVING EFFLUENT QUALITY ON A BARRIER ISLAND Brett T. Messner, PE, Tetra Tech, Inc., 201 E Pine St, Suite 1000, Orlando, FL 32801 Brett.Messner@tetratech.com, Ph: 239-851-1225 Fred

More information

A general Description of the IAWQ activated sludge model No.1

A general Description of the IAWQ activated sludge model No.1 A general Description of the IAWQ activated sludge model No1 Introduction 1983 IAWQ(IAWPRC) IAWQ model review, carbon oxidation, nitrification, denitrification single-sludge system task group IAWQ 1987

More information

Preparing for Nutrient Removal at Your Treatment Plant

Preparing for Nutrient Removal at Your Treatment Plant Summer Seminar Emerging Issues in the Water/Wastewater Industry Preparing for Nutrient Removal at Your Treatment Plant Rajendra P. Bhattarai, P.E., BCEE Austin Water Utility Ana J. Peña-Tijerina, Ph.D.,

More information

Performance evaluation of a full-scale advanced phase isolation ditch process by using real-time control strategies

Performance evaluation of a full-scale advanced phase isolation ditch process by using real-time control strategies Korean J. Chem. Eng., 31(4), 611-618 (2014) DOI: 10.1007/s11814-013-0271-9 INVITED REVIEW PAPER INVITED REVIEW PAPER pissn: 0256-1115 eissn: 1975-7220 Performance evaluation of a full-scale advanced phase

More information

AquaNereda Aerobic Granular Sludge Technology

AquaNereda Aerobic Granular Sludge Technology Aerobic Granular Sludge AquaNereda Aerobic Granular Sludge Technology The AquaNereda Aerobic Granular Sludge (AGS) Technology is an innovative biological wastewater treatment technology that provides advanced

More information

Short-Cut Nitrogen Removal: A State of the Art Review

Short-Cut Nitrogen Removal: A State of the Art Review Short-Cut Nitrogen Removal: A State of the Art Review Jose Jimenez, Ph.D., P.E. Brown and Caldwell Outline Introduction Overview of nitrogen (N) removal in wastewater Conventional N removal Nitritation-Denitritation/

More information

Proprietary AquaTron technology incorporates three (3) innovative features that increase its efficiency and reduces cost:

Proprietary AquaTron technology incorporates three (3) innovative features that increase its efficiency and reduces cost: THE AQUATRON The Technology The AquaTron is the result of over twenty years of research, development, testing and practical experience. Using the principles of the activated sludge biological process,

More information

Increasing Denitrification in Sequencing Batch Reactors with Continuous Influent Feed

Increasing Denitrification in Sequencing Batch Reactors with Continuous Influent Feed Increasing Denitrification in Sequencing Batch Reactors with Continuous Influent Feed ABSTRACT In this study, the denitrification capacity of a continuous influent feed sequencing batch reactor (SBR) was

More information

Biological Nutrient Removal Operations. December 9 th, 2015 Presenter Georgine Grissop PE, BCEE

Biological Nutrient Removal Operations. December 9 th, 2015 Presenter Georgine Grissop PE, BCEE Biological Nutrient Removal Operations December 9 th, 2015 Presenter Georgine Grissop PE, BCEE Outline Nutrient Removal Overview Process Considerations Process Monitoring Problems & Troubleshooting Questions

More information

OCTOBER 31, NAMI Environmental Conference BEST PRACTICES: IMPROVING WW SYSTEMS

OCTOBER 31, NAMI Environmental Conference BEST PRACTICES: IMPROVING WW SYSTEMS OCTOBER 31, 2012 NAMI Environmental Conference BEST PRACTICES: IMPROVING WW SYSTEMS Best Practices System Profiling Oxygen Management Carbon Management Real Time monitoring and automation System Profiling

More information

THE DEMON ANAMMOX PROCESS: RESOURCE SAVINGS THROUGH SIDE STREAM TREATMENT, AND THE STEPS TOWARDS AN ENERGY NEUTRAL WWTP PRESENTED AT: NC AWWA-WEA 97

THE DEMON ANAMMOX PROCESS: RESOURCE SAVINGS THROUGH SIDE STREAM TREATMENT, AND THE STEPS TOWARDS AN ENERGY NEUTRAL WWTP PRESENTED AT: NC AWWA-WEA 97 THE DEMON ANAMMOX PROCESS: RESOURCE SAVINGS THROUGH SIDE STREAM TREATMENT, AND THE STEPS TOWARDS AN ENERGY NEUTRAL WWTP PRESENTED AT: NC AWWA-WEA 97 TH ANNUAL CONFERENCE PRESENTED ON: 13 NOVEMBER, 2017

More information

Application of the AGF (Anoxic Gas Flotation) Process

Application of the AGF (Anoxic Gas Flotation) Process Application of the AGF (Anoxic Gas Flotation) Process Dennis A. Burke Environmental Energy Company, 6007 Hill Road NE, Olympia, WA 98516 USA (E-mail: dennis@makingenergy.com http//www.makingenergy.com)

More information

NITROGEN REMOVAL USING TERTIARY FILTRATION. Suzie Hatch & Colum Kearney. Sydney Water Corporation

NITROGEN REMOVAL USING TERTIARY FILTRATION. Suzie Hatch & Colum Kearney. Sydney Water Corporation Winner of Actizyme Prize for Best Paper at the NSW Operators Conference held in September 2004 NITROGEN REMOVAL USING TERTIARY FILTRATION Paper Presented by : Suzie Hatch & Colum Kearney Authors: Suzie

More information

AquaPASS. Aqua MixAir System. Phase Separator. System Features and Advantages. Anaerobic. Staged Aeration. Pre-Anoxic.

AquaPASS. Aqua MixAir System. Phase Separator. System Features and Advantages. Anaerobic. Staged Aeration. Pre-Anoxic. PHASED ACTIVATED SLUDGE SYSTEM PHASED ACTIVATED SLUDGE SYSTEM Aqua-Aerobic Systems has led the industry in time-managed, biological technology since 1984. In 2004, Aqua-Aerobic applied its expertise in

More information

AMMONIA REMOVAL USING MLE PROCESS EXPERIENCES AT BALLARAT NORTH. David Reyne. Central Highlands Water Authority

AMMONIA REMOVAL USING MLE PROCESS EXPERIENCES AT BALLARAT NORTH. David Reyne. Central Highlands Water Authority AMMONIA REMOVAL USING MLE PROCESS EXPERIENCES AT BALLARAT NORTH Paper Presented by : David Reyne Author: David Reyne, Plant Operator Wastewater Treatment, Central Highlands Water Authority 65 th Annual

More information

Chapter 9 Nitrification

Chapter 9 Nitrification Chapter 9 Nitrification 9.0 Nitrification - The microbiological oxidation of NH 4+ -N to NO 2- -N and NO 3- -N. NH 4+ -N removal is a mandated process for some wastewaters because i) NH 4 + consumes oxygen

More information

MODELING OF AN IFAS PROCESS WITH FUNGAL BIOMASS TREATING PHARMACEUTICAL WASTEWATER Main Street West Hamilton, ON, Canada L8S 1G5

MODELING OF AN IFAS PROCESS WITH FUNGAL BIOMASS TREATING PHARMACEUTICAL WASTEWATER Main Street West Hamilton, ON, Canada L8S 1G5 MODELING OF AN IFAS PROCESS WITH FUNGAL BIOMASS TREATING PHARMACEUTICAL WASTEWATER Oliver Schraa 1, Paul Robinson 2, and Anette Selegran 2 1 Hydromantis, Inc 32-1685 Main Street West Hamilton, ON, Canada

More information

EHS SMART-Treat Onsite Moving Media Treatment System

EHS SMART-Treat Onsite Moving Media Treatment System EHS SMART-Treat Onsite Moving Media Treatment System Sampling &Testing Protocol for SMART-Treat Wastewater Treatment System SAMPLING DURING OPERATION OF THE TREATMENT SYSTEM-IF DESIRED Sampling and analytical

More information

Brightwater: The Design Challenges of a 39 mgd (150 MLD) Membrane Bioreactor

Brightwater: The Design Challenges of a 39 mgd (150 MLD) Membrane Bioreactor Brightwater: The Design Challenges of a 39 mgd (150 MLD) Membrane Bioreactor J. Komorita 1, P. Burke 2, B. Youker 2, and G. Crawford 2 1 King County, 2 CH2M HILL ABSTRACT Many Membrane Bioreactor (MBR)

More information

TWO YEARS OF BIOLOGICAL PHOSPHORUS REMOVAL WITH AN ADVANCED MSBR SYSTEM AT THE SHENZHEN YANTIAN WASTEWATER TREATMENT PLANT

TWO YEARS OF BIOLOGICAL PHOSPHORUS REMOVAL WITH AN ADVANCED MSBR SYSTEM AT THE SHENZHEN YANTIAN WASTEWATER TREATMENT PLANT TWO YEARS OF BIOLOGICAL PHOSPHORUS REMOVAL WITH AN ADVANCED MSBR SYSTEM AT THE SHENZHEN YANTIAN WASTEWATER TREATMENT PLANT Chester Yang, Ph.D., Gaowei Gu, Baowei Li, Hongyuan Li, Wanshen Lu, Lloyd Johnson,

More information

ANOXIC BIOREACTOR SIZING

ANOXIC BIOREACTOR SIZING ANOXIC BIOREACTOR SIZING 1 ANOXIC BIOREACTORS 2 SELECTOR TANK Small tanks located upstream of the aeration tanks that receive the wastewater for treatment and the returned RAS to limit the growth of organisms

More information

Effect of the start-up length on the biological nutrient removal process

Effect of the start-up length on the biological nutrient removal process Water Pollution IX 521 Effect of the start-up length on the biological nutrient removal process F. J. Fernández 1, J. Villaseñor 1 & L. Rodríguez 2 1 Department of Chemical Engineering, ITQUIMA, University

More information

Energy Reduction and Biological Process Performance Improvements with Right-Sized Equipment and Next-Generation Process and Aeration Controls

Energy Reduction and Biological Process Performance Improvements with Right-Sized Equipment and Next-Generation Process and Aeration Controls 52 nd Annual Conference October 2018 Energy Reduction and Biological Process Performance Improvements with Right-Sized Equipment and Next-Generation Process and Aeration Controls randy.chann@wastewater.com

More information

ADVANCING NOVEL PROCESSES FOR BIOLOGICAL NUTRIENT REMOVAL

ADVANCING NOVEL PROCESSES FOR BIOLOGICAL NUTRIENT REMOVAL ADVANCING NOVEL PROCESSES FOR BIOLOGICAL NUTRIENT REMOVAL PNCWA Boise, Idaho September 15, 29 Presented by: Alexander Mockos, EIT Co-Author: Dr. Erik Coats University of Idaho, Civil Engineering Department

More information

BIOLOGICAL PHOSPHOROUS REMOVAL AN OPERATOR S GUIDE

BIOLOGICAL PHOSPHOROUS REMOVAL AN OPERATOR S GUIDE BIOLOGICAL PHOSPHOROUS REMOVAL AN OPERATOR S GUIDE ABSTRACT If you have ever faced a rising effluent phosphorous concentration and you are relying on biological phosphorous removal, the information offered

More information

American Water College 2010

American Water College 2010 Vocabulary Activated Sludge (Part 1) Activated Sludge Sludge particles produced in raw or settled wastewater (primary effluent) by the growth of organisms (including zoogleal bacteria) in aeration tanks

More information

COLD WEATHER NITRIFICATION OF LAGOON EFFLUENT USING A MOVING BED BIOFILM REACTOR (MBBR) TREATMENT PROCESS

COLD WEATHER NITRIFICATION OF LAGOON EFFLUENT USING A MOVING BED BIOFILM REACTOR (MBBR) TREATMENT PROCESS ABSTRACT COLD WEATHER NITRIFICATION OF LAGOON EFFLUENT USING A MOVING BED BIOFILM REACTOR (MBBR) TREATMENT PROCESS Mr. Flemming G. Wessman 1 and Mr. Chandler H. Johnson 1 AnoxKaldnes, Inc., 58 Weybosset

More information

ISAM INTEGRATED SURGE ANOXIC MIX

ISAM INTEGRATED SURGE ANOXIC MIX ISAM INTEGRATED SURGE ANOXIC MIX P r o v e n T e c h n o l o g y FLUIDYNE S ISAM IS A TOTAL TREATMENT SYSTEM incorporating BOD, TSS and nitrogen removal along with sludge reduction in an integrated system.

More information

Liquid Stream Fundamentals: Whole Plant Modeling

Liquid Stream Fundamentals: Whole Plant Modeling FACT SHEET Liquid Stream Fundamentals: Whole Plant Modeling Whole plant modelling has become an increasingly more accessible and popular tool to help engineers and operators understand, design, and optimize

More information

Adaptating dynamic simulation to a wastewater treatment plant reconstruction

Adaptating dynamic simulation to a wastewater treatment plant reconstruction Acta Universitatis Sapientiae Agriculture and Environment, 1 (2009) 38-45 Adaptating dynamic simulation to a wastewater treatment plant reconstruction Endre DOMOKOS 1, Viola SOMOGYI 1, Ákos RÉDEY 1, T.

More information

Advanced Optimization of Biological Nutrient Removal Plants Using Feedforward and Feedback Control-Case Studies

Advanced Optimization of Biological Nutrient Removal Plants Using Feedforward and Feedback Control-Case Studies Advanced Optimization of Biological Nutrient Removal Plants Using Feedforward and Feedback Control-Case Studies Rob Dexter*, Patrick Keller** and Rudolf Bauer** * DCM Process Control PTY Ltd. A.B.N. 89

More information

WASTEWATER TREATMENT PLANT MASTER PLAN 6. BUSINESS CASE EVALUATION OF ALTERNATIVES

WASTEWATER TREATMENT PLANT MASTER PLAN 6. BUSINESS CASE EVALUATION OF ALTERNATIVES WASTEWATER TREATMENT PLANT MASTER PLAN 6. BUSINESS CASE EVALUATION OF ALTERNATIVES A range of potential ammonia limits were identified for alternatives evaluation, as discussed in Section 2.2.5. This chapter

More information