NIPPON PAPER RO SYSTEM + 2 Others

Size: px
Start display at page:

Download "NIPPON PAPER RO SYSTEM + 2 Others"

Transcription

1 NIPPON PAPER RO SYSTEM + 2 Others 1 March 2014 Greg Wyrick District Account Manager John Zora District Account Manager

2 2 Purpose: Review the design, function, layout, and operation of the RO system. Process: minute presentation. Payoff: Gain a better understanding of the RO system

3 3 But First, What is RO? RO: Reverse Osmosis

4 Osmosis 4 Osmotic Head Semi- Permeable Membrane Strong Solution NaCl Na + Cl - H 2 O H 2 O H 2 O Pure Water Pure Water Flow

5 REVERSE OSMOSIS 5 Applied Pressure, P F > Osmotic Pressure, P O Semi- Permeable Membrane What is our applied pressure? Strong Solution (Mill Water) H 2 O H 2 O H 2 O Pure Water Pure Water Flow

6 6 WHY RO at Nippon? Old Boiler: 225 PSIG Zeolite Softened Water No Turbine Paper Mill Steam Use Cogen Boiler: 900 PSIG 20 MW Turbine Steam Extraction + Condensing

7 7

8 8 Why An RO and Not a DEMIN DEMINS: ACID and CAUSTIC Regen. Safety Concern Potential for silica, hardness breakthrough Potential for acid excursions Wide Range of flow rates RO s: Consistent Permeate Quality No acid or caustic regen system

9 Filter Plant Nippon Paper Cogen Boiler Pretreatment System Boiler Make-up Filters (3) MMF s Nalco 7408 Water Softeners (2) & Brine Tank PMP Injection Quill Local Sample Local Sample Local Sample Reverse Osmosis Units (2) Concentrate Mixed Bed Polisher Boiler Makeup Water Tank Nalco 1820 Qty: 2 RO Product Boiler Makeup Water Pumps (2) Boiler Makeup Water Heat Exchanger Process Condensate Qty: 4 Condensate Polisher (2) & Brine Tank Local Sample Local Sample Sample to Test Station Steam From Turbine Surface Condenser Steam Eductor System Final Inter Gland Steam Condenser Surface Condenser: Sample to Test Station To Vacuum Drain Flash Tank Surface Condenser Condensate Low Temp Heat Exchanger Condensing EconomizerSoot Blower Flue Gas Chamber: Condensate Surface Condenser Condensate High Temperature Heat Exchanger: # Steam Sample to Test Station Nalco Conquor CNQR3475 To BFW Pump

10 Basic Block Diagram of Water Flow Elwha River Treatment Plant Mill Filter Plant RO Water Treatment Building Storage Tank Deaerator BOILER Steam Turbine Cond. Cond. Polisher Paper Mill Cond.

11 Basic Block Diagram of RO TREATMENT BUILDING Round Tank Mill Water Booster Pump High Efficiency Filters Softeners RO s Mixed Bed Polishers Storage Tank

12 12 Booster Pump Mill water pressure variations Too low, RO kick out. Protect high pressure pump.

13 High Efficiency Filters 13

14 14 High Efficiency Filters Purpose: Remove un-dissolved solids Particles larger than 0.5 microns Process: Pass water through a high efficiency filter Payoff: Produce water of SDI less than 5 Minimize RO Fouling

15 15 UltraSand Plus High Efficiency Filter Standard Multi-Media Filter

16 microns microns Ions Proteins Viruses Ions Bacteria Proteins Sand Viruses Bacteria Bacteria Sand Sand Bacteria Sand 16 Coagulant Addition Coagulant Addition Std. Filtration Std. Filtration Coagulant added to increase 'application envelope'... Coagulant added to increase 'application envelope' HE Filtration HE Filtration Microfiltration Microfiltration Ultrafiltration Ultrafiltration Nanofiltration Nanofiltration Reverse Osmosis Reverse Osmosis

17 17 Top Over Bottom (TOB): Feed water enters and creates an area of turbulence over the bed and a tangential force that scrubs particles off the bed surface. The tangential force carries particles back toward the filter inlet. At the same time, this tangential force also pushes sand towards the filter inlet, creating a camel hump. Behind this hump is an area of low turbulence that allows for deposition of particles that have been scrubbed off of the sand. This low-turbulence area keeps filling with particles until spilling over the hump into the high-turbulence area of the filter.

18 18 Top Over Bottom (TOB): As particles begin to collect on the turbulent-side of the hump adds to the particle loading of the influent water. When the loading of solids in the feed water exceeds the capacity of the water to hold them, the particles begin to drop out on the filter bed, This increases the differential pressure through the bed, signaling time to backwash the filter. Filters are backwashed when the differential pressure reaches 15 psig. Ref: Pg. 12

19 This is all great, but the mill has a filter plant Why does it need a High Efficiency Filter 19 SDI SILT DENSITY INDEX

20 SDI Tester 20 Pressure Gauge Filter Holder, 0.45 micron, 47 mm

21 21

22 Silt Density Index 22 Measures Fouling potential of RO membranes with suspended solids. Higher the number, the greater the potential. Most membrane manufactures require an SDI below 5 for warranty.

23 23 SDI = 1 (t i/t f ) x 100 T Where: t i = initial time to fill to 500 ml t f = time after T to fill to 500 ml T = Time, usually 15 minutes.

24 BASELINE DATA COLLECTION 24 From October 2010 to September 2012 SDI were ran 14 times. Values ranged from Far too high for an RO Need to a high efficiency filter

25 PARTICLE SIZE DISTRIBUTION 25 Sample sent to a lab, analyze for particle counts and volumes with proscribed micron ranges. From October 2010 to October 2012, 20 samples sent in to establish baseline.

26 26

27 How Well Does the Filter Work 27 February 10, 2014 Effluent: SDI = 3.1 Influent: SDI = 18

28 October 2, Effluent SDI = 1.06 Influent SDI = 36

29 29 PSD Data Range, micron Particle % removal Volume % removal % 71% % 99% % % 99% % 99% % 99% Total n/a 99%

30 30 Operations All 3 run at a time. Booster pump starts when there is a call for water, ie level is make-up water tank. Backwash based on differential pressure. Automatically backwash in sequence once differential pressure is reached. Takes 8 minutes per unit.

31 Softeners 31 Purpose: Remove hardness. Process: Pass water over cation resin. Payoff: Protect RO from hardness based scale & no need to add an anti-scalant.

32 32 Operations 2 units: one in service; one standby Scavenge Chlorine out Run to a gallons throughput Auto switch Auto regenerate. Operators keep brine tank full of salt

33 RO 33

34 3 Basic Components 1. Prefilter - Red 2. Pump - Yellow 3. RO Membranes - Blue

35 35 Purpose: Remove dissolved ions and colloidal silica from water to condition water for use as boiler feed water. Process: Water is passed through a semi-permeable membrane. Payoff: Water is almost good enough for economical use as BFW. Last step is to pass through a mixed bed polisher.

36 2:1 Array System 84 gpm Permeate 126 gpm 84 gpm 42 gpm 42 gpm 168 gpm 42 gpm 84 gpm 84 gpm 42 gpm 42 gpm 42 gpm Concentrate to sewer 75% Recovery 25% Rejection

37 37

38 38

39 39

40 40

41 41

42 42 Feed spacer Permeate spacer Membrane leaf

43 As the feed water travels down the membrane(s), it becomes more concentrated: Brine becomes more concentrated Product Feed Concentrate

44 Pressure Vessel: Multi-Module Pressure Vessel- Product [Permeate] Feed Concentrate [Reject] Contains 1, 3, 4, 6, or 7 modules in series 44

45 TFC Membrane: 0.2 micron 40 micron 120 micron Flow always goes INTO the structure Polyamide Ultra-thin Barrier Layer Microporous Polysulfone Reinforcing Fabric REVERSE FLOW WILL LIFT THE MEMBRANE FROM THE BACKING 45

46 TFC Membrane 46 Polyamide Barrier Layer Polysulfone Backing Support Layer 46

47 47 Mixed Bed Polisher After RO Remove any ions (hardness, silica) that gets past the RO.

48 48 Mill Water: Silica: Ave. 6.8 ppm; low: 5.5, high % rejection from RO Silica in permeate = ppm Ave ppm Low 0.18 ppm High At 50 cycles: 6.8 ppm Ave. 5.5 ppm Low 9 ppm High Upper boiler limit for silica is 8 ppm

49 49 Silica: Ave. 6.8 ppm; low: 5.5, high % rejection from RO Silica in permeate = 0.34 ppm Ave ppm Low 0.45 ppm High At 50 cycles: 17 ppm Ave ppm Low 22.5 ppm High Upper boiler limit for silica is 8 ppm Can not run at 50 cycles. Have to increase blowdown and run at 23 cycles.

50 Control and Monitoring 50

51

52

53 Inhibitor Control ph ORP Temperature NTU Pressures Flow

54

55 Automated Tank Level and Usage Reporting

56

57

58 3DT for Membranes Equipment Automation Service 58 Chemicals & Consumables

59 Immediate Feedback of Problems Customer Notifications! 3DTTfM Monitoring

60 Cleaning at the right time Cleaning should have been done here Inneffective cleanings

61 Multiple data streams come into a central unit P P P us F P P us F FL T O ph Permeate Feed Water FL P Concentrate

62

63

64 Weekly Operations Report 64

65 Weekly Operations Report 65

66 THANK YOU! 66

Filtration & Pretreatment Basics

Filtration & Pretreatment Basics 2014 Service Technician Training Program Filtration & Pretreatment Basics Mr. Stephen Lowe, CWT Cascade Water Services, Inc. Boiler System Layout Pretreatment Softeners - Feedwater Boiler Filtration Boiler

More information

Water supplied by Marafiq does not meet the process requirements.

Water supplied by Marafiq does not meet the process requirements. WATER TREATMENT In Industries Water is used for: a. Drinking b. Cleaning c. Cooling d. Producing Steam e. Process requirement Why we need to treat water? For human consumption a. Water to be purified (Make

More information

Reducing Energy & Water In Your Boiler House Charles Astbury Commercial Operations GE Water & Process Technologies

Reducing Energy & Water In Your Boiler House Charles Astbury Commercial Operations GE Water & Process Technologies Reducing Energy & Water In Your Boiler House Charles Astbury Commercial Operations GE Water & Process Technologies Presented by What areas can you impact? Reduce Blowdown Saves water and energy Recover

More information

ULTRAFILTRATION FOR REVERSE OSMOSIS-PRETREATMENT

ULTRAFILTRATION FOR REVERSE OSMOSIS-PRETREATMENT ULTRAFILTRATION FOR REVERSE OSMOSIS-PRETREATMENT Ajay Popat Chief Executive Officer Ion Exchange Waterleau Ltd. BASIC CONCEPTS OF ULTRAFILTRATION Ultrafiltration Pre-treatment is the best pre-treatment

More information

Reducing Energy & Water In Your Boiler House Charles Astbury Commercial Operations GE Water & Process Technologies

Reducing Energy & Water In Your Boiler House Charles Astbury Commercial Operations GE Water & Process Technologies Reducing Energy & Water In Your Boiler House Charles Astbury Commercial Operations GE Water & Process Technologies Presented by What areas can you impact? Reduce Blowdown Saves water and energy Recover

More information

Reverse Osmosis. Background to Market and Technology

Reverse Osmosis. Background to Market and Technology Reverse Osmosis Background to Market and Technology 1 Technology and Applications Reverse osmosis has been commercial for over 25 years. 60MLD plants built in Saudi Arabia 20 years ago. Current sales of

More information

Use of Spiral Wound UF in RO Pretreatment

Use of Spiral Wound UF in RO Pretreatment Use of Spiral Wound UF in RO Pretreatment Authors: Harry Dalaly, Asia Pacific Sales Manager, Hydranautics and Yeoh Cheik How, Facilities Senior Engineer, Hewlett-Packard Singapore The Hewlett-Packard Singapore

More information

Membrane Technology: From Manufacture to. May Production

Membrane Technology: From Manufacture to. May Production Membrane Technology: From Manufacture to May 2018 Production Osmosis Graphic pulled from https://earthobservatory.nasa.gov/features/water/page2.php Water Sources Surface Waters Ground Water Seawater Lakes

More information

performance of the ultrapure make-up system at Turkey Point Nuclear Power Plant

performance of the ultrapure make-up system at Turkey Point Nuclear Power Plant Water Technologies & Solutions technical paper performance of the ultrapure make-up system at Turkey Point Nuclear Power Plant Authors: Stephen P. Ellis, Laboratory Manager, Ionics and Richard Steinke,

More information

Overview. Commercial High-Purity Water Systems and Applications. Quality Water Is Our Business

Overview. Commercial High-Purity Water Systems and Applications. Quality Water Is Our Business Commercial High-Purity Water Systems and Applications Quality Water Is Our Business Overview High-purity water: definitions High-purity water: methods o Distillation o Deionization o Membrane filtration

More information

REVERSE OSMOSIS INSTALLATION AND OPERATION MANUAL. R12-Wall Mount

REVERSE OSMOSIS INSTALLATION AND OPERATION MANUAL. R12-Wall Mount REVERSE OSMOSIS INSTALLATION AND OPERATION MANUAL R12-Wall Mount IMPORTANT Please read the entire manual before proceeding with the installation and startup: Do not use where the water is microbiologically

More information

Engineering & Equipment Division

Engineering & Equipment Division Since their development as practical unit operations in the late 1950 s and early 1960 s, reverse osmosis (RO) and ultra filtration (UF) have been continually expanding the scope of their applications.

More information

Optimizing Steam and Cooling Systems for Reliability and Sustainability. Presented By: Kevin Emery

Optimizing Steam and Cooling Systems for Reliability and Sustainability. Presented By: Kevin Emery Optimizing Steam and Cooling Systems for Reliability and Sustainability Presented By: Kevin Emery Kevine@chemtreat.com 804-317-2381 Optimizing Steam and Cooling Systems for Reliability and Sustainability

More information

Effluent Treatment Methods And Reverse Osmosis and its Rejects Handling

Effluent Treatment Methods And Reverse Osmosis and its Rejects Handling Effluent Treatment Methods And Reverse Osmosis and its Rejects Handling Dr P P Lal Krishna Chief Executive Officer Ramky Pharma City (India) Ltd Developer of Jawaharlal Nehru Pharma City - Vizag TREATMENT

More information

Presented by: Jeff Freitag, The Water Guy Jon Tiegs, General Manager

Presented by: Jeff Freitag, The Water Guy Jon Tiegs, General Manager Presented by: Jeff Freitag, The Water Guy Jon Tiegs, General Manager OBJECTIVES Understand The Importance of Practicing Key Performance Indicators (KPI s) in Your Boiler Room Identify Key Components of

More information

Membrane Technique MF UF NF - RO

Membrane Technique MF UF NF - RO Membrane Technique MF UF NF - RO AquaCare GmbH & Co. KG Am Wiesenbusch 11 45966 Gladbeck, Germany +49-20 43-37 57 58-0 +49-20 43 37 57 58-90 www.aquacare.de e-mail: info@aquacare.de Membrane Technique

More information

REVERSE OSMOSIS, THE OPTIMAL SOLUTION FOR WATER TREATMENT WITH MEMBRANES TECHNOLOGY

REVERSE OSMOSIS, THE OPTIMAL SOLUTION FOR WATER TREATMENT WITH MEMBRANES TECHNOLOGY Bulletin of the Transilvania University of Braşov Vol. 10 (59) Special Issue No. 1-2017 Series I: Engineering Sciences REVERSE OSMOSIS, THE OPTIMAL SOLUTION FOR WATER TREATMENT WITH MEMBRANES TECHNOLOGY

More information

Lenntech. Tel Fax

Lenntech. Tel Fax Case History Lenntech info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 Site Information Location: Beijing, China Capacity: Second Phase, 150m 3 /h; Third Phase, 160m 3 /h Time

More information

Petro-Canada Re-Uses Treated Edmonton Waste Water. Coking.com Safety Seminar Calgary September 2008

Petro-Canada Re-Uses Treated Edmonton Waste Water. Coking.com Safety Seminar Calgary September 2008 Petro-Canada Re-Uses Treated Edmonton Waste Water Coking.com Safety Seminar Calgary September 2008 1 Membrane-Treated Waste Water Project Petro-Canada has completed modifications at its Edmonton refinery

More information

Total Water Management in Thermal Power Station By Mr. N. Ramachandran - Associate Vice President (Technology)

Total Water Management in Thermal Power Station By Mr. N. Ramachandran - Associate Vice President (Technology) Total Water Management in Thermal Power Station By Mr. N. Ramachandran - Associate Vice President (Technology) Introduction Large volumes of water are required by thermal power stations for various applications

More information

Water Treatment Technology

Water Treatment Technology Lecture 4: Membrane Processes Technology in water treatment (Part I) Water Treatment Technology Water Resources Engineering Civil Engineering ENGC 6305 Dr. Fahid Rabah PhD. PE. 1 Membrane Processes Technology

More information

PURPOSE PROCESS PAYOFF

PURPOSE PROCESS PAYOFF Water Reuse 4/04/13 PURPOSE PROCESS PAYOFF Water Water Everywhere but not a drop to drink! Seawater versus Water Reuse UF - RO for brackish waste water streams: 0.81.2 kw h/m3 MBR RO for brackish waste

More information

Reduced Footprint Water Treatment Technology

Reduced Footprint Water Treatment Technology H 2 Oil & Gas An Group Company Reduced Footprint Water Treatment Technology Up to 50% footprint saving compared to conventional technology. www.h2oilandgas.com REDft REDft How it works In the REDft process,

More information

KTDA SEMINAR WATER TREATMENT PRESENTATION. John Waema

KTDA SEMINAR WATER TREATMENT PRESENTATION. John Waema KTDA SEMINAR WATER TREATMENT PRESENTATION John Waema INTRODUCTION Filtration Systems Packaged Plants Ultrafiltration Plants Dosing Systems Reverse Osmosis Plants Mobile Water Treatment Plants Global water

More information

THE CURRENT USE OF HOLLOW FIBRE ULTRAFILTRATION AS PRE-TREATMENT FOR REVERSE OSMOSIS

THE CURRENT USE OF HOLLOW FIBRE ULTRAFILTRATION AS PRE-TREATMENT FOR REVERSE OSMOSIS THE CURRENT USE OF HOLLOW FIBRE ULTRAFILTRATION AS PRE-TREATMENT FOR REVERSE OSMOSIS Membrane Processes Lower Pressure Membrane Processes Microfiltration (UF) Ultrafiltration (MF) Higher Pressure Membrane

More information

PRESENTATION OF DESALINATION VIA REVERSE OSMOSIS

PRESENTATION OF DESALINATION VIA REVERSE OSMOSIS Via Pietro Nenni, 15-27058 VOGHERA ITALY Tel. +39 0383 3371 Fax +39 0383 369052 E-mail: info@idreco.com PRESENTATION OF DESALINATION VIA REVERSE OSMOSIS Reverse osmosis is the finest level of filtration

More information

Membrane Protection Resins Ion Exchange Resins and Reverse Osmosis in Partnership

Membrane Protection Resins Ion Exchange Resins and Reverse Osmosis in Partnership Membrane Protection Resins Ion Exchange Resins and Reverse Osmosis in Partnership By Francis Boodoo The Purolite Company Brian Windsor Purolite International Ltd Classical Ion Exchange in Partnership with

More information

PURE WATER. Installation, Operation and Maintenance Manual. Reverse Osmosis System Series PWRO440. Important. Notes. Table of Contents IOM-WQ-PWRO440

PURE WATER. Installation, Operation and Maintenance Manual. Reverse Osmosis System Series PWRO440. Important. Notes. Table of Contents IOM-WQ-PWRO440 Installation, Operation and Maintenance Manual Reverse Osmosis System Series PWRO440 IOM-WQ-PWRO440 PURE WATER Important Please read the entire manual before proceeding with the installation and startup:

More information

Reverse Osmosis. Lecture 17

Reverse Osmosis. Lecture 17 Reverse Osmosis Lecture 17 Reverse osmosis Reverse osmosis is a membrane technology used for separation also reffered as Hyperfiltration. In a typical RO system the solution is first filtered through a

More information

Water Reuse/Recycle. Can this be Performed Economically in Today s Mills

Water Reuse/Recycle. Can this be Performed Economically in Today s Mills Water Reuse/Recycle Can this be Performed Economically in Today s Mills Spring Eastern Canada BLRBAC/ PAPTAC Steam and Steam Power meeting June 22-23, 2010 Presented by Paul Sehl, Regional Sales Manager

More information

using EDI to meet the needs of pure water production

using EDI to meet the needs of pure water production Water Technologies & Solutions technical paper using EDI to meet the needs of pure water production Authors: Ted Prato and Christopher Gallagher, Ionics This paper was originally presented at the 61st

More information

27 th ANNUAL WATEREUSE SYMPOSIUM CHALLENGES OF HIGH-SULFATE WASTEWATER RECYCLE. Abstract. Introduction

27 th ANNUAL WATEREUSE SYMPOSIUM CHALLENGES OF HIGH-SULFATE WASTEWATER RECYCLE. Abstract. Introduction 27 th ANNUAL WATEREUSE SYMPOSIUM CHALLENGES OF HIGH-SULFATE WASTEWATER RECYCLE William Matheson, Duraflow, Tewksbury, MA Abstract A cement products manufacturer, having a sulfate and total dissolved solid

More information

REVERSE OSMOSIS WATER TREATMENT

REVERSE OSMOSIS WATER TREATMENT REVERSE OSMOSIS WATER TREATMENT LTF 2, LTF 3 and LTF 4 SERIES RO SYSTEMS 14,400 TO 252,000 GALLONS PER DAY AND LARGER Lakeside Water for Affordable Pure Water Technology 1 P age Packaged Reverse Osmosis

More information

PURE WATER. Installation, Operation and Maintenance Manual. Wall Mounted Commercial Reverse Osmosis Systems. Series PWR2511. Table Of Contents.

PURE WATER. Installation, Operation and Maintenance Manual. Wall Mounted Commercial Reverse Osmosis Systems. Series PWR2511. Table Of Contents. Installation, Operation and Maintenance Manual Wall Mounted Commercial Reverse Osmosis Systems Series PWR2511 IOM-WQ-PWR2511 PURE WATER! WARNING Please read carefully before proceeding with installation.

More information

Air Connection on Rack. Filtrate Connection on Rack

Air Connection on Rack. Filtrate Connection on Rack What is a membrane? Module with Flow holes Air Connection on Rack Filtrate Connection on Rack 1 module 1rack Goal is to use membranes to separate or filter solids, organisms, and molecules from the liquid

More information

GENESEE GENERATING STATION UNITS 4 AND 5 WATER CONSUMPTION AND EFFLUENT DISCHARGE CHARACTERIZATION REPORT

GENESEE GENERATING STATION UNITS 4 AND 5 WATER CONSUMPTION AND EFFLUENT DISCHARGE CHARACTERIZATION REPORT GENESEE GENERATING STATION UNITS 4 AND 5 WATER CONSUMPTION AND EFFLUENT DISCHARGE CHARACTERIZATION REPORT B&V PROJECT NO. 180144 B&V FILE NO. 41.0812 REV. 0 ISSUED FOR PERMIT APPLICATION Black & Veatch

More information

The Basics. Reverse Osmosis is a process that is used to remove. Front Side 1. Controller

The Basics. Reverse Osmosis is a process that is used to remove. Front Side 1. Controller The Basics Front Side 1. Controller 2. Transformer/relay 3. Inlet 3 /4 BSPM 4. Drain Outlet 3 /4 BSPM 5. GAC Filter 6. Pressure control 7. Low pressure gauge 8. Pump pressure gauge 9. Back pressure gauge

More information

Recovery and reuse of water from effluents of cooling tower

Recovery and reuse of water from effluents of cooling tower J. Indian Inst. Sci., July Aug. 2005, 85, 215 221 Indian Institute of Science. Recovery and reuse of water from effluents of cooling tower S. KALIAPPAN*, C. SATHISH AND T. NIRMALKUMAR Centre for Environmental

More information

By: Curt Roth Vice President, Engineering EconoPure Water Systems, LLC. Desalination Pre Treatment with LFNano. An EconoPure White Paper

By: Curt Roth Vice President, Engineering EconoPure Water Systems, LLC. Desalination Pre Treatment with LFNano. An EconoPure White Paper An EconoPure White Paper 2024 N. Broadway Santa Ana, CA 92706 USA 1+(714) 258 8559 www.econopure.com Desalination Pre Treatment with LFNano By: Curt Roth Vice President, Engineering EconoPure Water Systems,

More information

Lenntech. Using EDI to Meet the Needs of Pure Water Production. EDI Process. Summary. Introduction

Lenntech. Using EDI to Meet the Needs of Pure Water Production. EDI Process. Summary. Introduction Lenntech info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 Using EDI to Meet the Needs of Pure Water Production Authors: Ted Prato and Christopher Gallagher, Ionics This paper

More information

A Brief about Reverse Osmosis & Ultrafiltration!!

A Brief about Reverse Osmosis & Ultrafiltration!! OOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOO A Brief about Reverse Osmosis & Ultrafiltration!! TABLE OF CONTENT 2 OOOOOOOOO OOOOOOOOO OOOOOOOOO About us......3 Product Portfolio...4

More information

Boiler Water Treatment

Boiler Water Treatment Boiler Water Treatment Preventive Solutions and Complete Treatment Programs Corrosion, scaling and deposition can reduce the operating efficiency of the boiler and all the systems connected to the water/steam

More information

PRODUCTS & APPLICATIONS COURSE WATER TREATMENT PRESENTATION John Waema

PRODUCTS & APPLICATIONS COURSE WATER TREATMENT PRESENTATION John Waema PRODUCTS & APPLICATIONS COURSE WATER TREATMENT PRESENTATION John Waema INTRODUCTION Filtration Systems Dosing Systems Packaged Plants Reverse Osmosis Systems Waste Water Treatment Plants Mobile Water Treatment

More information

Texas Desal 2014 Reverse Osmosis Membrane Basics How and Why Membranes Work Dan Muff - Toray

Texas Desal 2014 Reverse Osmosis Membrane Basics How and Why Membranes Work Dan Muff - Toray Texas Desal 2014 Reverse Osmosis Membrane Basics How and Why Membranes Work Dan Muff - Toray Spiral Module History 1960 s - 2012 1964 - Spiral Wound Module Patented 1969 - Global RO Module Sales $1 million

More information

Bucking the Industry Trend. Simple Change to Water System Saves New Jersey Manufacturer $23,000 Annually

Bucking the Industry Trend. Simple Change to Water System Saves New Jersey Manufacturer $23,000 Annually Simple Change to Water System Saves New Jersey Manufacturer by Kevin Preising Sales Engineer . Summary: Over the past two decades, the trend in the water treatment industry has been towards more and more

More information

Boiler Water Chemistry: Getting From the Source to the Boiler Colleen M. Layman, PE

Boiler Water Chemistry: Getting From the Source to the Boiler Colleen M. Layman, PE Boiler Water Chemistry: Getting From the Source to the Boiler Colleen M. Layman, PE colleen.layman@hdrinc.com 2017 HDR, Inc., all rights reserved. Goals Minimize Scaling Limit Deposition Prevent Corrosion

More information

Advanced water purifier system operation manual and setup guide

Advanced water purifier system operation manual and setup guide Advanced water purifier system operation manual and setup guide What is Reverse Osmosis? Reverse osmosis, also known as hyper filtration, is the finest filtration known. This process will allow the removal

More information

Seawater Desalination Plant General Specification

Seawater Desalination Plant General Specification Seawater Desalination Plant General Specification *Desalination plant design will depend on indivdual customer s requiements. Chlorine Dosing System of different functions such as the stroke length and

More information

Some Standard Membranes: Filmtec Membrane, Hydronatics Membrane, Torry membrane and Koch Membrane.

Some Standard Membranes: Filmtec Membrane, Hydronatics Membrane, Torry membrane and Koch Membrane. REVERSE OSMOSIS (RO) water treatment process involves water being forced under pressure ( Osmatic Pressure ) through a semipermeable membrane. Temporary and permanent hardness, Total Dissolved Soilds (TDS),

More information

CONTENTS. reverse osmosis _02. the R.O. plant _04. Micro series _06. LE/HR series _08. series from 500 to 1250 l/h _10

CONTENTS. reverse osmosis _02. the R.O. plant _04. Micro series _06. LE/HR series _08. series from 500 to 1250 l/h _10 REVERSE OSMOSIS CONTENTS reverse osmosis _02 the R.O. plant _04 Micro series _06 LE/HR series _08 series from 500 to 1250 l/h _10 series from 1500 to 28000 l/h _12 accessories _14 customised configurations

More information

Addressing increasing wastewater volumes in industrial and oil & gas operations using thermal systems

Addressing increasing wastewater volumes in industrial and oil & gas operations using thermal systems Water Arabia 2013 Conference & Exhibition Innovative Water and Wastewater Technologies for a Sustainable Environment 4 to 6 February, 2013 Le Meridien Khobar, Saudi Arabia Addressing increasing wastewater

More information

Operating Guidelines Cleaning

Operating Guidelines Cleaning Technical Bulletin Operating Guidelines Cleaning Cleaning Pure Water Membrane Elements Introduction Regular cleaning of Desal membrane elements is important because foulants can build up on membrane surfaces,

More information

Physical and Chemical Processes for Advanced Wastewater Treatment

Physical and Chemical Processes for Advanced Wastewater Treatment Chapter 16 Physical and Chemical Processes for Advanced Wastewater Treatment 1.0 PROCESS SELECTION CONSIDERATIONS 16-6 2.0 SECONDARY EFFLUENT FILTRATION 16-6 2.1 Background 16-6 2.1.1 Goals 16-8 2.1.2

More information

Hollow Fiber and Tubular UF Pilot Testing Procedures & Case Studies

Hollow Fiber and Tubular UF Pilot Testing Procedures & Case Studies CROWN Solutions, Inc. Dave Christophersen, 5.5.04 Hollow Fiber and Tubular UF Pilot Testing Procedures & Case Studies Several membrane technologies are available to use for industrial water preparation

More information

5.B Generation of pharmaceutical water Author: Michael Gronwald Co-Author: Dr. Ralph Gomez / Up06

5.B Generation of pharmaceutical water Author: Michael Gronwald Co-Author: Dr. Ralph Gomez / Up06 Generation of pharmaceutical water Generation of pharmaceutical water Author: Michael Gronwald Co-Author: Dr. Ralph Gomez / Up06 Here you will find answers to the following questions: What are the different

More information

Producing High-Purity Recycled Water for Industrial Applications with Microfiltration and Reverse Osmosis: Lessons Learned

Producing High-Purity Recycled Water for Industrial Applications with Microfiltration and Reverse Osmosis: Lessons Learned Producing High-Purity Recycled Water for Industrial Applications with Microfiltration and Reverse Osmosis: Lessons Learned ABSTRACT Mallika Ramanathan*, Alicia Cohn*, John Hake*, Ken Abraham**, Srinivas

More information

Industrial Waste Management and Water Treatment Opportunities November Saudi Aramco: Public

Industrial Waste Management and Water Treatment Opportunities November Saudi Aramco: Public Industrial Waste Management and Water Treatment Opportunities November 2018 Disclaimer The next slides contain forward-looking statements regarding future events based on current expectations, estimates,

More information

OsmoBC Integrated Membrane Systems

OsmoBC Integrated Membrane Systems OsmoBC Integrated Membrane Systems For Industrial Wastewater Treatment Fluid Technology Solutions, Inc. OsmoF2O FO Membranes HBCR High Brine Concentrator OsmoZLD Treatment Process INTEGRA Disk Filtration

More information

Commercial. Softeners Filters Reverse Osmosis

Commercial. Softeners Filters Reverse Osmosis Softeners Filters Reverse Osmosis Commercial Expertise has dedicated Professional Engineers with decades of commercial water treatment experience to compliment our knowledgeable field sales team. Together

More information

Agenda. Pretreatment Background Typical Contaminants Practical Examples Methods of Treatment and References

Agenda. Pretreatment Background Typical Contaminants Practical Examples Methods of Treatment and References Pretreatment of Seawater for Desalination Plants Richard Dixon, ITT Agenda Pretreatment Background Typical Contaminants Practical Examples Methods of Treatment and References 2 Typical Constituents in

More information

Dewvaporation Carrier-Gas Enhanced Atmospheric Pressure Desalination. Noah Abbas and Kehinde Adesoye

Dewvaporation Carrier-Gas Enhanced Atmospheric Pressure Desalination. Noah Abbas and Kehinde Adesoye Dewvaporation Carrier-Gas Enhanced Atmospheric Pressure Desalination Noah Abbas and Kehinde Adesoye Outline Existing Technologies Reverse Osmosis Thermal Processes Dewvaporation Explanation Mathematical

More information

Cartwright Consulting Co.

Cartwright Consulting Co. Cartwright Consulting Co. WWW.CARTWRIGHT-CONSULTING.COM pscartwright@msn.com United States Office European Office 8324 16 th Avenue South President Kennedylaan 94 Minneapolis, MN 55425-1742 2343 GT Oegstgeest

More information

Key words: Integrated Membrane System, IMS, Seawater Reverse Osmosis, SWRO, SW30HRLE- 400, Ultrafiltration, UF, ZeeWeed 1000

Key words: Integrated Membrane System, IMS, Seawater Reverse Osmosis, SWRO, SW30HRLE- 400, Ultrafiltration, UF, ZeeWeed 1000 Yuhuan Power Plant Seawater Desalination System: Integrated Membrane System Introduction and Operation Performance Analysis Jinsheng Liu a, Shenglin Pang a, Minjia Zhao b, Zhuodan Liao b, Jia Ning b a

More information

Water Solutions for the Power Industry

Water Solutions for the Power Industry Water Solutions for the Power Industry Resourcing the world WATER TECHNOLOGIES Water Solutions for the power industry Veolia Water Technologies specialises in water and wastewater treatment solutions for

More information

Cartwright Consulting Co.

Cartwright Consulting Co. Cartwright Consulting Co. WWW.CARTWRIGHT-CONSULTING.COM pscartwright@msn.com United States Office European Office 8324 16 th Avenue South President Kennedylaan 94 Minneapolis, MN 55425-1742 2343 GT Oegstgeest

More information

RO System Design & CSMPRO v6.0 Program

RO System Design & CSMPRO v6.0 Program RO System Design & CSMPRO v6.0 Program CONTENTS 1 System Design 2 CSMPRO v6.0 Introduction 1 1 System Design 2 Consideration of Feed Source, Application The membrane system design depends on Feed Source,

More information

"Significant Cost Savings Obtained Using Advanced Membrane Systems for Cooling Tower Water Treatment and in ZLD plants

Significant Cost Savings Obtained Using Advanced Membrane Systems for Cooling Tower Water Treatment and in ZLD plants Better Lives. Better Planet.SM "Significant Cost Savings Obtained Using Advanced Membrane Systems for Cooling Tower Water Treatment and in ZLD plants Webcast December 2012 Bernhard Doll Pall GmbH Disclaimer

More information

REVERSE OSMOSIS AND NANOFILTRATION MEMBRANE SYSTEMS

REVERSE OSMOSIS AND NANOFILTRATION MEMBRANE SYSTEMS A Fundamental Guide to Industrial REVERSE OSMOSIS AND NANOFILTRATION MEMBRANE SYSTEMS A PUBLICATION OF SAMCO TECHNOLOGIES TABLE OF CONTENTS 1 2 3 4 5 What Are Reverse Osmosis and Nanofiltration and How

More information

RiOs Essential 5, 8, 16, 24 Water Purification Systems

RiOs Essential 5, 8, 16, 24 Water Purification Systems RiOs Essential 5, 8, 16, 24 Water Purification Systems A reliable, user-friendly pure water solution EMD Millipore is a division of Merck KGaA, Darmstadt, Germany A reliable, user-friendly pure water solution

More information

Summary of Issues Strategies Benefits & Costs Key Uncertainties Additional Resources

Summary of Issues Strategies Benefits & Costs Key Uncertainties Additional Resources Summary of Issues Strategies Benefits & Costs Key Uncertainties Additional Resources KEY POINT: Appropriate pre-treatment can prevent fouling and scaling, optimize membrane performance, and extend membrane

More information

WATER RECYCLING SOLUTIONS

WATER RECYCLING SOLUTIONS WATER RECYCLING SOLUTIONS Reverse Osmosis De-Mineralization Softening Sand/ Carbon Filtration Cartridge/ Bag Filtration Zero Liquid Discharge EVIAN ENGINEERING PRIVATE LIMITED A-80, Mohan Garden, Uttam

More information

Protegra CS RO Series. Meeting All Your Pure Water Demands. Water Technologies

Protegra CS RO Series. Meeting All Your Pure Water Demands. Water Technologies Protegra CS RO Series Meeting All Your Pure Water Demands Water Technologies Solenoid switch gauge Pump RO-Module Flow meter Pre-Filter control Solenoid Service Restrictor Protegra CS RO Series flowsheet

More information

Ultrafiltration Technical Manual

Ultrafiltration Technical Manual Ultrafiltration Technical Manual Copyright by: inge AG Flurstraße 17 86926 Greifenberg (Germany) Tel.: +49 (0) 8192 / 997 700 Fax: +49 (0) 8192 / 997 999 E-Mail: info@inge.ag Internet: www.inge.ag Contents

More information

FILTRATION INDUSTRY -An Overview

FILTRATION INDUSTRY -An Overview FILTRATION INDUSTRY -An Overview Introduction The term filtration, as applied to water treatment, refers to the removal of suspended solids from water. In most cases it is the last stage in the pre treatment

More information

Modutech S.r.l. WDS SEAWATER DROPLET SYSTEM FOR FRESH WATER SUPPLY. Ing. Alessandro Cariani

Modutech S.r.l. WDS SEAWATER DROPLET SYSTEM FOR FRESH WATER SUPPLY. Ing. Alessandro Cariani Modutech S.r.l. WDS SEAWATER DROPLET SYSTEM FOR FRESH WATER SUPPLY Ing. Alessandro Cariani The world's water consumption rate is doubling every 20 years, outpacing by two times the rate of population growth.

More information

Treatability Study and Reverse Osmosis Pilot Study of Industrial Wastewater at a Wood Products Mill

Treatability Study and Reverse Osmosis Pilot Study of Industrial Wastewater at a Wood Products Mill Treatability Study and Reverse Osmosis Pilot Study of Industrial Wastewater at a Wood Products Mill NC AWWA-WEA 2017 Annual Conference Randall Foulke, PE, BCEE, LEED AP Tracey Daniels, EI November 14,

More information

IWC ZLD: New Silica Based Inhibitor Chemistry Permits Cost Effective Water Conservation for HVAC and Industrial Cooling Towers

IWC ZLD: New Silica Based Inhibitor Chemistry Permits Cost Effective Water Conservation for HVAC and Industrial Cooling Towers IWC 07-11 ZLD: New Silica Based Inhibitor Chemistry Permits Cost Effective Water Conservation for HVAC and Industrial Cooling Towers Report by Dan Duke Water Conservation Technology International water-cti.com

More information

The evolution of high purity water production

The evolution of high purity water production FEDI Fractional Electrodeionization from EDI to FEDI The evolution of high purity water production EDI THE CONVENTIOL PROCESS Reject Electrodeionization Cell DEIONIZED WATER Reject Electrodeionization

More information

Treated Effluent (TSE) Reuse Applications and Challenges. Saudi Arabia

Treated Effluent (TSE) Reuse Applications and Challenges. Saudi Arabia Treated Effluent (TSE) Reuse Applications and Challenges Saudi Arabia > Agenda General Treatment Technologies Cooling Towers Application Power Application Industry Application Brine Disposal TITRE PRÉSENTATION

More information

Copper Removal from Cooling Tower Blowdowns

Copper Removal from Cooling Tower Blowdowns Copper Removal from Cooling Tower Blowdowns By: Chris Howell and Dave Christophersen Originally Published: CSTR April 2006 Discharge of industrial non-contact cooling water (cooling tower blowdown) to

More information

DOW Ultrafiltration. Case History. DOW Ultrafiltration Modules Protect Reverse Osmosis System from High Iron

DOW Ultrafiltration. Case History. DOW Ultrafiltration Modules Protect Reverse Osmosis System from High Iron Case History Modules Protect Reverse Osmosis System from High Iron Site Information Location: ShanXi, China Capacity: 2074 m 3 /h (5283 gpm) Purpose: Pretreat waste water prior to RO system Time in Operation:

More information

Specifications: MoBetta Pro Series Water Store Skid 2600/5200/7800

Specifications: MoBetta Pro Series Water Store Skid 2600/5200/7800 Specifications: MoBetta Pro Series Water Store Skid 2600/5200/7800 Product Offering Overview Part Number Product Flow Rate Mobetta Pro Series Water Store Skid 2600-1.81 USGPM 2600/5200/7800 5200-3.62 USGPM

More information

ISSN: [Utama et al., 8(1): January, 2019] Impact Factor: 5.164

ISSN: [Utama et al., 8(1): January, 2019] Impact Factor: 5.164 IJESRT INTERNATIONAL JOURNAL OF ENGINEERING SCIENCES & RESEARCH TECHNOLOGY DESALINATION REJECT WATER UTILIZATION for REVERSE OSMOSIS PLANT RAW WATER Komang Gede Nara Utama*, Eko Supriyanto*, Matradji**,

More information

MEMBRANE CHEMICALS Presented by: Majid Karami

MEMBRANE CHEMICALS Presented by: Majid Karami MEMBRANE CHEMICALS Presented by: Majid Karami Introduction Water shortage is becoming a worldwide problem One of the main solutions to this problem is : Desalination of seawater or brackish water Desalination

More information

Industrial / Municipal

Industrial / Municipal 17/04/15 F19-1 Flow & Metering Accessories Industrial / Municipal EX Series IP Series FT Series DL76 Flow Monitoring and Control Magnetic Flow Meters (Magmeters) Paddle Wheel Flow Meters Contacting Meters

More information

MEMBRANE SEPARATION. Microfiltration Ultrafiltration Nanofiltration Reverse Osmosis Desalination. Satisfies Your High-Purity Water Needs

MEMBRANE SEPARATION. Microfiltration Ultrafiltration Nanofiltration Reverse Osmosis Desalination. Satisfies Your High-Purity Water Needs Microfiltration Ultrafiltration Nanofiltration Reverse Osmosis Desalination MEMBRANE SEPARATION Satisfies Your High-Purity Water Needs Municipal Commercial and Industrial Applications MICROFILTRATION ULTRAFILTRATION

More information

Western BLRBAC Review/Refresher of Tappi Water Quality Guidelines and Contamination Procedures for mill boilers operating on high purity water

Western BLRBAC Review/Refresher of Tappi Water Quality Guidelines and Contamination Procedures for mill boilers operating on high purity water Western BLRBAC Review/Refresher of Tappi Water Quality Guidelines and Contamination Procedures for mill boilers operating on high purity water October 29, 2014 Commitment makes the best chemistry. 1 TAPPI

More information

Depth Filtration with Microfiber Cloth Enhances Performance of Ultrafiltration as Pretreatment to Seawater Desalination Systems

Depth Filtration with Microfiber Cloth Enhances Performance of Ultrafiltration as Pretreatment to Seawater Desalination Systems Depth Filtration with Microfiber Cloth Enhances Performance of Ultrafiltration as Pretreatment to Seawater Desalination Systems Emerging Technologies in Filtration October 6, 2015 David Holland, Terence

More information

[Previous Chapter] [Table of Contents] [Next Chapter]

[Previous Chapter] [Table of Contents] [Next Chapter] 1 of 6 4/5/2006 1:09 AM [Previous Chapter] [Table of Contents] [Next Chapter] DEPT. OF HEALTH, EDUCATION, AND Date: 10-21-80 Number: 36 WELFARE PUBLIC HEALTH SERVICE FOOD AND DRUG ADMINISTRATION *ORA/ORO/DEIO/IB*

More information

POREX Tubular Membrane Filter (TMF ) Applied in a ZLD System as Critical Solid/Liquid Separation Process

POREX Tubular Membrane Filter (TMF ) Applied in a ZLD System as Critical Solid/Liquid Separation Process POREX Tubular Membrane Filter (TMF ) Applied in a ZLD System as Critical Solid/Liquid Separation Process Abstract Introduction Beijing Shougang Biomass Energy Technology Co., Ltd, a branch company of SHOUGANG

More information

Membrane Filtration Technology: Meeting Today s Water Treatment Challenges

Membrane Filtration Technology: Meeting Today s Water Treatment Challenges Membrane Filtration Technology: Meeting Today s Water Treatment Challenges Growing global demand for clean water and increasing environmental concerns make membrane filtration the technology of choice

More information

KEYWORDS: Ion exchange, compressed short bed, wastewater, filter, secondary water, tertiary water, reverse osmosis (RO), electrodeionization (EDI).

KEYWORDS: Ion exchange, compressed short bed, wastewater, filter, secondary water, tertiary water, reverse osmosis (RO), electrodeionization (EDI). Increased Water Treatment Plant Capacity at a Mexican Power Station Using Micro Media Filters Ahead of RO and Replacing EDI with Ion Exchange RUSI KAPADIA, MICHAEL SHEEDY, DONALD SWAINE, Eco-Tec Inc.,

More information

WATER TREATMENT TRAINING. Eng. Festus Ng eno

WATER TREATMENT TRAINING. Eng. Festus Ng eno WATER TREATMENT TRAINING Eng. Festus Ng eno SOURCES OF WATER Borehole water nature of rock around aquifer High mineral content Surface sources bacteria, colour, sediments Shallow well water bacteria, minerals

More information

PURE-PRO REVERSE OSMOSIS SYSTEM

PURE-PRO REVERSE OSMOSIS SYSTEM REVERSE OSMOSIS SYSTEM 15 RO36000 Industrial RO System 01 Feed water quality requirement 01 System specifications 02 Part list 07 Installation 08 Operation process & maintenance 10 Trouble shooting 13

More information

Texas Desal 2017 NEXED EDR Technology Demonstration 22nd September Evoqua Water Technologies LLC

Texas Desal 2017 NEXED EDR Technology Demonstration 22nd September Evoqua Water Technologies LLC Texas Desal 2017 NEXED EDR Technology Demonstration 22nd September 2017 2017 Evoqua Water Technologies LLC AGENDA Evoqua Overview NEXED EDR Technology Development Background NEXED Technical Overview Evoqua

More information

Boiler/Cooling Water Processes and Parameters

Boiler/Cooling Water Processes and Parameters Boiler/Cooling Water Processes and Parameters Outline Feedwater Internal Boiler Water Condensate Blowdown Cooling Water Process Water Feedwater Objectives of boiler feedwater treatment: Prevent introduction

More information

Flootech. General Presentation. Power Industry. Flootech Oy 2012

Flootech. General Presentation. Power Industry. Flootech Oy 2012 General Presentation Power Industry 1 Oy Office located in Turku, Finland Privately held company with 40 years history in water treatment Flootech Oy offers state of the art, novel water treatment technologies

More information

A s populations increase and sources of highquality

A s populations increase and sources of highquality E-249 04-10 Desalination Methods for Producing Drinking Water *Justin K. Mechell and Bruce Lesikar A s populations increase and sources of highquality fresh drinking water decrease, many communities have

More information

City of Woodbury. Red Bank Water Treatment Plant - Treatment Alternatives Analysis November 2016

City of Woodbury. Red Bank Water Treatment Plant - Treatment Alternatives Analysis November 2016 City of Woodbury Red Bank Water Treatment Plant - Treatment Alternatives Analysis November 2016 Background Remington & Vernick was authorized to study and design a treatment process for removal of PFC

More information

How A Vertical Tube Falling Film Evaporator Can Be Used to Deliver the Lowest Total Life Cycle Cost for Alberta Produced Water Treatment

How A Vertical Tube Falling Film Evaporator Can Be Used to Deliver the Lowest Total Life Cycle Cost for Alberta Produced Water Treatment How A Vertical Tube Falling Film Evaporator Can Be Used to Deliver the Lowest Total Life Cycle Cost for Alberta Produced Water Treatment Overview Minimizing Installation Costs Evaporator Pilot Program

More information