E 094 E 103 E 143 Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min

Size: px
Start display at page:

Download "E 094 E 103 E 143 Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min"

Transcription

1 Return Filters E 9 E E Tank top mounting Connection up to G Nominal flow rate up to l/min Description Application In the return line circuits of hydraulic systems. Performance features Protection against wear: By means of filter elements that, in full-flow filtration meet even the highest demands regarding cleanliness classes. Protection against malfunction: By means of full-flow filtration in the system return, the pumps above all are protected from dirt particles remaining in the system after assembly, repairs, or which are generated by wear or enter the system from outside. Return Filter E Special features By-pass valve: The location close to the inlet port prevents dirt particles retained by the filter element from entering into the clean oil side. Removable bowl: In case of maintenance the filter bowl is removed together with the filter element - therefore dirt particles are not flushed back into the tank. Extension pipe: A correct extension pipe length ensures oil outlet below minimum oil level and prevents foaming. Filter elements Flow direction from outside to centre. The star-shaped pleating of the filter material results in: large filter surfaces low pressure drop high dirt-holding capacities long service life Ventilating Filter Ventilation of the reservoir by an integral star-shape pleated filter element: removable (replace annually!) splash-proof fineness µm Filter maintenance By using a clogging indicator the correct moment for maintenance is stated and guarantees the optimum utilization of the filter life. Subject to change.-e Page

2 Materials Screw-on cap: Filter head: Filter bowl: Seals: Filter media: Polyamide, GF-reinforced Alluminium alloy Polyamide, CF-reinforced, electrically conducting NBR (FPM on request) EXAPOR MAX - inorganic multi-layer microfibre web Paper - cellulose web, impregnated with resin Accessories Electrical and optical clogging indicators are available on request. Dimensions and technical data see cataologue sheet 6.. An optional oil separator (Part No. E.7) is available on request. Extension pipes on the bowl outlet are available in several lengths on request. A self-assembly system for installation of extension pipes can be ordered. For detailed information please see catalogue sheet.9. Characteristics Nominal flow rate Up to l/min (see Selection Chart, column ). The nominal flow rates indicated by ARGO-HYTOS are based on the following features: closed by-pass valve at ν mm /s element service life > operating hours at an average fluid contamination of,7 g per l/min flow volume flow velocity in the connection lines, m/s Connection Threaded ports according to ISO 8 or DIN. Sizes see Selection Chart, column 6 (other port threads on request) Filter fineness µm(c)... µm(c) β-values according to ISO 6889 (see Selection Chart, column and diagram Dx) Dirt-holding capacity Values in g test dust ISO MTD according to ISO 6889 (see Selection Chart, column ) Diagrams Hydraulic fluids Mineral oil and biodegradable fluids (HEES and HETG, see info-sheet.). With high filling conditions we recommend an electrical conductivity >_ ps/m at C. Temperature range - C... + C (temporary - C... + C) Viscosity at nominal flow rate at operating temperature: ν < 6 mm /s as starting viscosity: ν max = mm /s at initial operation: The recommended starting viscosity can be read from the diagram D (pressure drop as a function of the kinematic viscosity) as follows: Find the 7 % p of the cracking pressure of the by-pass valve on the vertical axis. Draw a horizontal line so that it intersects the p curve at a point. Read this point on the horizontal axis for the viscosity. Operating pressure Max. bar Mounting position Preferably vertical, outlet downwards p-curves for complete filters in Selection Chart, column D flow volume at ν = mm /s ( = casing empty) kinematic viscosity at nominal flow,,, E 9,, Q [l/min] ν [mm /s] Page Subject to change.-e

3 D flow volume at ν = mm /s ( = casing empty) kinematic viscosity at nominal flow,,,,, E + 7 Q [l/min] 6 8 ν [mm /s] D flow volume at ν = mm /s ( = casing empty) kinematic viscosity at nominal flow,,,,, E Q [l/min] ν [mm /s] Filter fineness curves in Selection Chart, column Dx Filtration ratio β for particles > x µm Filtration ratio β as a function of particle size x obtained by the Multi-Pass Test according to ISO 6889 Efficiency [%] The abbreviations represent the following β-values resp. finenesses: For EXAPOR MAX and Paper elements: EX = β (c) = EXAPOR MAX 7EX = β 7 (c) = EXAPOR MAX EX = β (c) = EXAPOR MAX 6EX = β 6 (c) = EXAPOR MAX P = β (c) = Paper Based on the structure of the filter media of the P paper elements, deviations from the printed curves are quite probable. For screen elements: S = screen material with mesh size µm 6S = screen material with mesh size 6 µm S = screen material with mesh size µm Tolerances for mesh size accordung to DIN 89 Particle size x [µm] (for particles larger than the given particle size x) For ventilating filter elements: CL = 99, % Abscheidegrad für Partikel der Größe µm For special applications, finenesses differing from these curves are also available by using special composed filter material. Subject to change.-e Page

4 Selection Chart Part No. Nominal flow rate Pressure drop see diagram D/curve no. Filter fineness see Diagr. Dx Connection A Dirt-holding capacity Cracking pressure of by-pass Symbol Replacement element Part No. l/min g bar kg E 9-66 D/ P G /, P.6-,8 L.- (CL) - E 9-67 D/ P G /, P.6-,8 - - Weight Replacement ventilating filter Part No. (Filter fineness, see diagrams) Remarks E -67 D/ EX 8 G¾, V.6-, L.- (CL) - E -677 D/ EX 8 G¾, V.6-, - - E D/ EX G /, V.6-6, L.- (CL) - E D/ EX G /, V.6-6, - - E -898 D/ 6EX G, V.6-8, L.- (CL) - E -888 D/ 6EX G, V.6-8, - - E D/ P G /, P.6-*, L.- (CL) - E D/ P G /, P.6-*, - - E D/ EX 8 G /, V.7-, L.- (CL) - E D/ EX 8 G /, V.7-, - - E -676 D/ EX 8 G, V.7-6, L.- (CL) - E -686 D/ EX 8 G, V.7-6, - - E -888 D/ 6EX 8 G, V.7-8, L.- (CL) - E -688 D/ 6EX 8 G, V.7-8, - - E -8 D/ P 7 G, P.7-*, L.- ( CL) - E -86 D/ P 7 G, P.7-*, - - * Paper media supported with metal gauze All filters are delivered with a plugged clogging indicator connection M x,. As clogging indicators either manometers or electrical pressure switches can be used. Optional extension pipes adapt the filter length to various tank depths. For ordering of accessories please use the below mentioned codes. Order example: The filter E -676 has to be supplied with an extension pipe for a mounting depth of mm. Order description: E -676 / EV Part No. (Basic unit) Mounted extension pipe (7 various lengths are available on request) E 9: EV, EV 9, EV, EV 8, EV, EV, EV E : EV 96, EV 6, EV, EV, EV, EV, EV 6 E : EV 97, EV 7, EV, EV, EV, EV 6, EV 7 For the suitable clogging indicators please see catalogue sheet 6.. Remarks: The switching pressure of the electrical pressure switch has always to be lower than the cracking pressure of the by-pass valve (see Selection Chart, column 7). Clogging indicators are optional and always delivered detached from the filter. The filters listed in this chart are standard filters. Other designs available on request. Page Subject to change.-e

5 Dimensions I +(EV-K) H A B S S Ventilating filter Fineness µm (replaceable) G F Oil separator optional ARGO-HYTOS Part No.: E.7 EV K Ø C Ø D Dia hole in reservoir U Max oil level under stationary conditions when using an oil separator V ØE Design without ventilating filter Design with ventilating filter O Connection M x, for clogging indicator Required mounting surface Q 9º º T 9º º M L L c 9º Q P N P I R Measurements For dimension EV see selection chart Type A B C min/max D E F G H I I K L M N O P P E 9 G ¾ 87/9 7, 8, 88, E G¾, G 87/9 7, 8, 88, E G¾, G 87/9 7, 8, 88, Type Q R S T U V E 9, 7, AF AF E, 7, AF AF E, 7, AF AF Symbols Subject to change.-e Page

6 Spare Parts Pos. Designation Part No. Screw-on cap E. Flat gasket N.8 Compression spring N.7 Filter element see Chart / Col. 9 Filter bowl E9 * E 9.9 Filter bowl E * E.9 Filter bowl E * E.9 6 O-ring 69, x, N7.7 7 Ventilating filter L.-K 8 Housing (for pos. 7) L..8 9 Flat gasket (for versions E.7 without oil separator) Oil separator with Pos. E.7 Flat gasket (for versions E.8 with oil separator) * Specify mounting depth (EV) in mm The functions of the complete filters as well as the outstanding features of the filter elements assured by ARGO-HYTOS can only be guaranteed if original ARGO-HYTOS spare parts are used. Quality Assurance Quality management according to DIN EN ISO 9 To ensure constant quality in production and operation, ARGO-HYTOS filter elements undergo strict controls and tests according to the following ISO standards: ISO 9 ISO 9 ISO 9 ISO 968 ISO 6889 ISO 8 Verification of collapse/burst pressure rating Verification of fabrication integrity (Bubble Point Test) Verification of material compatibility with fluids Evaluation of pressure drop versus flow characteristics Multi-Pass-Test (evaluation of filter fineness and dirt-holding capacity Determination of resistance to flow fatigue using high viscosity fluid Various quality controls during the production process guarantee the leakfree function and solidity of our filters. Illustrations may sometimes differ from the original. ARGO-HYTOS is not responsible for any unintentional mistake in this specification sheet. Page 6 Subject to change.-e

D 090 D 100 In-line mounting Connection up to G¾ Nominal flow rate up to 110 l/min

D 090 D 100 In-line mounting Connection up to G¾ Nominal flow rate up to 110 l/min Return Filters D 9 D In-line mounting Connection up to G¾ Nominal flow rate up to l/min Description Application In the return line circuits of hydraulic systems. Performance features Protection against

More information

Return Filters D 090 D 100. In-line mounting Connection up to G¾ Nominal flow rate up to 110 l/min e

Return Filters D 090 D 100. In-line mounting Connection up to G¾ Nominal flow rate up to 110 l/min e Return Filters D 9 D In-line mounting Connection up to G¾ Nominal flow rate up to l/min.5-e Description Application In the return line circuits of hydraulic systems. Performance features Protection against

More information

E 443 E 453 E 463 E 643. Tank top mounting Connection up to SAE 2 Nominal flow rate up to 550 l/min e

E 443 E 453 E 463 E 643. Tank top mounting Connection up to SAE 2 Nominal flow rate up to 550 l/min e R e t u r n F i l t e rs E 443 E 453 E 463 E 643 Tank top mounting Connection up to SAE 2 Nominal flow rate up to 550 l/min 20.50-4e D e s c r i p t i o n Application In the return line circuits of hydraulic

More information

E 444 E 454 E 464 E 644 Tank top mounting Connection up to SAE 2 Nominal flow rate up to 680 l/min / gpm

E 444 E 454 E 464 E 644 Tank top mounting Connection up to SAE 2 Nominal flow rate up to 680 l/min / gpm Return Filters E E 5 E 6 E 6 Tank top mounting Connection up to SAE Nominal flow rate up to 68 l/min / 79.7 gpm Description Application In the return line circuits of hydraulic systems. erformance features

More information

HD 152 HD 172 In-line mounting Operating pressure up to 630 bar Nominal flow rate up to 190 l/min

HD 152 HD 172 In-line mounting Operating pressure up to 630 bar Nominal flow rate up to 190 l/min High Pressure Filters Worldline HD HD 7 In-line mounting Operating pressure up to bar Nominal flow rate up to 9 l/min Description Application In the high pressure circuits of hydraulic systems. Performance

More information

High Pressure Filters Worldline 100 HD 049 HD 069. In-line mounting Operating pressure up to 9137 psi Nominal flow rate up to 27.7 gpm. 40.

High Pressure Filters Worldline 100 HD 049 HD 069. In-line mounting Operating pressure up to 9137 psi Nominal flow rate up to 27.7 gpm. 40. High Pressure Filters Worldline 00 HD 09 HD 069 In-line mounting Operating pressure up to 9 psi Nominal flow rate up to 2. gpm 0.5-us Description Application In the high pressure circuits of hydraulic

More information

HD 790 HD 990. In-line mounting Operating pressure up to 6525 psi Nominal flow rate up to 265 gpm us d

HD 790 HD 990. In-line mounting Operating pressure up to 6525 psi Nominal flow rate up to 265 gpm us d H i g h re s s u re F i l t e rs Wo r l d l i n e 4 0 0 HD 790 HD 990 In-line mounting Operating pressure up to 6525 psi Nominal flow rate up to 265 gpm 40.90-1us 30.30-2d D e s c r i p t i o n Application

More information

Return Line Filter RFM

Return Line Filter RFM Return Line Filter RFM Flow rates up to 85 l/min Pressure range up to 1 bar Material: Aluminium/Steel/Synthetic material Return line filters type RFM are designed to be mounted on tank tops to filter out

More information

Process Inline Filter, Change-Over

Process Inline Filter, Change-Over Process Inline Filter, Change-Over -503-130x -520x 1. TECHNICAL SPECIFICATIONS 1.1 GENERAL Inline filters, types PRFL and duplex inline filters are designed for process engineering and chemical plants.

More information

Water Absorbing Filter Elements

Water Absorbing Filter Elements Water Absorbing Filter Elements EXAPOR AQUA Quick and efficient dewatering of hydraulic and lubrication oils Water in hydraulic and lubrication oils may have the following causes: Radiator leakage Environment

More information

Suction Filter - SE. Working Temperature From -25 to +110 C. Materials. Aluminium alloy Spin-on cartridge: Steel Bypass valve: Polyammide

Suction Filter - SE. Working Temperature From -25 to +110 C. Materials. Aluminium alloy Spin-on cartridge: Steel Bypass valve: Polyammide COMPONENTS Pressure (ISO 077-:00) Max working:, MPa ( bar) Test:,5 MPa (5 bar) Bursting:,5 MPa (5 bar) Collapse, differential for the filter element (ISO 9): 00 kpa ( bar) Bypass Valve Setting: 5 kpa (0,5

More information

PRESSURE FILTERS. BYPASS VALVE Setting: 600 kpa (6 bar) ± 10% WORKING TEMPERATURE From -25 to +110 C

PRESSURE FILTERS. BYPASS VALVE Setting: 600 kpa (6 bar) ± 10% WORKING TEMPERATURE From -25 to +110 C COMPONENTS PB MATERIALS Head: Cast iron Bowl: Steel Bypass valve: Steel Seals: NBR Nitrile (FKM - on request fluoroelastomer) Indicator housing: Brass PRESSURE (ISO 077-:) Max. working: 4 MPa (40 bar)

More information

SERIES LMP 210. Working pressure 60 bar. Style B. Style S D.I. D.I.

SERIES LMP 210. Working pressure 60 bar. Style B. Style S D.I. D.I. 0 SERIES Working pressure 60 bar Style S Style D.I. D.I. Technical data Filter housing (Materials) Head: nodised luminium Housing: nodised luminium ypass valve: Nylon Pressure Working pressure: 60 bar

More information

MDF. Pressure Filters MODULAR INLINE FILTER

MDF. Pressure Filters MODULAR INLINE FILTER MDF Pressure Filters MODULAR INLINE FILTER Pressure Filters MDF MDF 3,5 MPa (35 bar) Port sizes: etop 0507 Flow rates: 7 l/min TEHNIAL DATA Max. working pressure: 3,5 MPa (35 bar) Max. test pressure: 40

More information

SERIES LMP 210. Working pressure 60 bar. Style B. Style S D.I. D.I.

SERIES LMP 210. Working pressure 60 bar. Style B. Style S D.I. D.I. 0 SERIES Working pressure 60 bar Style S Style D.I. D.I. Technical data Filter housing (Materials) Head: luminium Housing: nodized luminium ypass valve: Nylon Pressure Working pressure: 60 bar (6 MPa)

More information

SERIES LMP 210. Working pressure 60 bar. Style B. Style S D.I. D.I.

SERIES LMP 210. Working pressure 60 bar. Style B. Style S D.I. D.I. 0 SERIES Working pressure 60 bar Style S Style D.I. D.I. Technical data Filter housing (Materials) Head: luminium Housing: nodised luminium ypass valve: Nylon Pressure Working pressure: 60 bar (6 MPa)

More information

OffLine Filter OLF 5

OffLine Filter OLF 5 + (0)120 6 OffLine Filter OLF Description The OLF and 10 series of filters are used for the offline, fine filtration of hydraulic oils. The series comprises numerous versions, for example with or without

More information

Body without bypass valve. Body with 6 BAR bypass valve. ELEMENT to be added Element Filtration Size 11 Size 12 Size 13 Size 21 Size 22 FA 5 micron

Body without bypass valve. Body with 6 BAR bypass valve. ELEMENT to be added Element Filtration Size 11 Size 12 Size 13 Size 21 Size 22 FA 5 micron Pressure (ISO 077-:) Max working: 3,5 MPa (35 bar) Test: 47 MPa (470 bar) Bursting: 95 MPa (9 bar) Collapse, differential for the filter element (ISO 94): series standard: MPa (0 bar) series H+: MPa (0

More information

Filter pressure regulator, Series AS3-FRE G 3/8 - G 1/2 filter porosity: 5 µm lockable with pressure gauge ATEX certified

Filter pressure regulator, Series AS3-FRE G 3/8 - G 1/2 filter porosity: 5 µm lockable with pressure gauge ATEX certified Filter regulator, Series AS3-FRE G 3/8 - G 1/2 filter porosity: 5 µm lockable with gauge ATEX certified 00119372 ATEX Maintenance Unit Parts Regulator type Regulator function Lock type Pressure supply

More information

Unloading Valve Series R4U

Unloading Valve Series R4U Characteristics Series RU Subplate mounted unloading valves series RU are used to unload a circuit at low pressure. The mechanically adjustable pressure signal to unload the main stage has to be applied

More information

UFR+L FILTER REGULATOR + LUBRICATOR

UFR+L FILTER REGULATOR + LUBRICATOR FEATURES The UFR+L filter regulator + lubricator is intended for the treatment of compressed air or compressed gas. Its function is that of supplying filtered, lubricated air at the desired pressure for

More information

Ion exchange Unit IXU 1/4 Series

Ion exchange Unit IXU 1/4 Series Ion exchange Unit IXU 1/4 Series Description The IXU series of easy-maintenance ion exchange units is designed to condition fire-resistant hydraulic and lubrication fluids based on phosphate esters (HFD-R)

More information

Clean Gas Filter. SF Series. Cartridge Type/Disposable Type IDFA IDFB IDH ID IDG IDK AMG AFF AM AMD AMH AME AMF ZFC SF SFD LLB AD GD SFC10

Clean Gas Filter. SF Series. Cartridge Type/Disposable Type IDFA IDFB IDH ID IDG IDK AMG AFF AM AMD AMH AME AMF ZFC SF SFD LLB AD GD SFC10 Clean Gas Filter Series Cartridge Type/Disposable Type Disposable type C0 Disposable type B30 Cartridge type 0 20 30 H HW T U B K MG FF M MD MH ME MF ZFC LLB D Cartridge type B0 B20 295 SMC Clean Gas Filter

More information

Series description Wilo-Drain STS 40

Series description Wilo-Drain STS 40 Series description Wilo-Drain STS 40 Series description Wilo-Drain STS 40 Subject to change 09/2008 WILO SE Wilo Catalogue C2 - - Sewage pumps from DN 32 to DN 800 Materials Pump housing: EN-GJL-250 Pedestal:

More information

MEDIUM PRESSURE FILTERS LPF Series Inline Filters 725 psi up to 74 gpm

MEDIUM PRESSURE FILTERS LPF Series Inline Filters 725 psi up to 74 gpm LPF Series Inline Filters 725 psi up to 74 gpm Hydraulic Symbol A B E6 Features LPF filters are manufactured with cast aluminum head and aluminum cold formed bowls. Aluminum alloy is water tolerant - anodization

More information

PAHT C pumps ATEX PAHT C pump

PAHT C pumps ATEX PAHT C pump MAKING MODERN LIVING POSSIBLE Lenntech info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 Data sheet ATEX PAHT C pump hpp.danfoss.com Table of Contents 1. Introduction...2 2.

More information

Filters & Elements. People. Passion. Performance

Filters & Elements. People. Passion. Performance Filters & Elements People. Passion. Performance Air Quality Solutions How clean is your compressed air? Atmospheric air naturally contains several impurities such as dust, various forms of hydrocarbons

More information

High Pressure Filter Assemblies

High Pressure Filter Assemblies High Pressure Filter Assemblies Up to 20,000 PSI (1378 bar) All stainless steel construction Stainless steel metal felt filter elements High Pressure T-Type Filter Assemblies Greater service life than

More information

Filtration Guideline. Introduction. STAUFF Filtration Technology offers two publications with knowledge and expertise about

Filtration Guideline. Introduction.  STAUFF Filtration Technology offers two publications with knowledge and expertise about Introduction STAUFF Filtration Technology offers two publications with knowledge and expertise about the applications: A. The compact Filtration Guideline Please have a look at the following pages. B.

More information

Instruction manual AS 300 CG. Waste water filtration unit. Im Geer 20, D Isselburg. Descriptioin / Type-No.: AS 300 CG Typ 539

Instruction manual AS 300 CG. Waste water filtration unit. Im Geer 20, D Isselburg. Descriptioin / Type-No.: AS 300 CG Typ 539 Waste water filtration unit Manufacturer: deconta GmbH Im Geer 20, D - 46419 Isselburg Descriptioin / Type-No.: Typ 539 Table of contents on page 1 Introduction 3 2 Basic safety advice 4 2.1 Intended use

More information

Demineralisation. PUROTAP expert. Installation Function Operation Service. Demineralised heating water.

Demineralisation. PUROTAP expert. Installation Function Operation Service. Demineralised heating water. EN Demineralised heating water Demineralisation PUROTAP expert Installation Function Operation Service Demineralised heating water makes heating systems safe in accordance with VDI 205 and SWKI BT 102-01

More information

- SPECIFICATIONS 200 PERFORMANCE RANGE and SELECTION CHART 201 TYPE KEY 202 CURVE SPECIFICATIONS 202 PERFORMANCE CURVE OPTIMA 203

- SPECIFICATIONS 200 PERFORMANCE RANGE and SELECTION CHART 201 TYPE KEY 202 CURVE SPECIFICATIONS 202 PERFORMANCE CURVE OPTIMA 203 CONTENTS Page - SPECIFICATIONS 200 PERFORMANCE RANGE and SELECTION CHART 201 TYPE KEY 202 CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 203 - CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE

More information

Water Cooled Oil Cooler

Water Cooled Oil Cooler Water Cooled Oil Cooler HOW Series Iron particle type: HOWF series FH Copper particle type: HOW series HOW Series Heat transfer area (Inside pipe) (m ) Heat exchange (kw) Flow rate (L/min) Oil side side

More information

YARWAY WYE-TYPE PIPELINE STRAINERS 900 SERIES

YARWAY WYE-TYPE PIPELINE STRAINERS 900 SERIES Protecting pipeline components from damaging particles with minimal pressure drop FEATURES Body material - ASTM and/or ASME as permitted under boiler code and power piping code. Provides assurance of quality

More information

SHREE DUJA SPRAY EQUIPMENTS

SHREE DUJA SPRAY EQUIPMENTS ELECTRIC DRILL INJECTION PISTON PUMP - SD 04 SD-04 is one-component grouting injector which is used to inject epoxy or polyurethane filling materials to water-leaking cracks. SD-04 is a professional Injection

More information

Suitable for use in a variety of fluid systems.

Suitable for use in a variety of fluid systems. Suitable for use in a variety of fluid systems. General Description Pipeline Wye Strainers are in thousands of applications in chemical, petroleum, pulp and paper, and utilities, as well as numerous commercial

More information

Filters & Elements. People. Passion. Performance

Filters & Elements. People. Passion. Performance Filters & Elements People. Passion. Performance Air Quality Solutions How clean is your compressed air? Atmospheric air naturally contains several impurities such as dust, various forms of hydrocarbons

More information

PARTS & ACCESSORIES: EATON DUPLEX BASKET STRAINERS FEATURES OPTIONS MODEL 53BTX DUPLEX (3/4 TO 4 ) MODEL 50 DUPLEX (5, 6, 8 )

PARTS & ACCESSORIES: EATON DUPLEX BASKET STRAINERS FEATURES OPTIONS MODEL 53BTX DUPLEX (3/4 TO 4 ) MODEL 50 DUPLEX (5, 6, 8 ) PARTS & ACCESSORIES: MODEL BTX & 0 Section 64 Page 64. Issue E FEATURES MODEL BTX DUPLEX (/4 TO 4 ) Dynamic sealing design for long life Easy-to-operate lever handle no gear box required Unique seat and

More information

Hydraulic Fluid Contamination and Assessment. Fluid Power Engineering Technology Instructor Hennepin Technical College

Hydraulic Fluid Contamination and Assessment. Fluid Power Engineering Technology Instructor Hennepin Technical College Hydraulic Fluid Contamination and Assessment Presented by: Ernie Parker Fluid Power Engineering Technology Instructor Hennepin Technical College 1 About 95% of all hydraulic problems are cause by heat,

More information

BEST ONE SUBMERSIBLE SUMP PUMPS EPA. Page Features & Applications 100 Exploded View 101 Pump & Motor Specifications 102 Selection Chart / Type key 103

BEST ONE SUBMERSIBLE SUMP PUMPS EPA. Page Features & Applications 100 Exploded View 101 Pump & Motor Specifications 102 Selection Chart / Type key 103 CONTENTS -SPECIFICATIONS Page Features & Applications 100 Exploded View 101 Pump & Motor Specifications 102 Selection Chart / Type key 103 -PERFORMANCE CURVES Performance Curve Best One 200 Performance

More information

HIGH PRESSURE FI TERS HPM SERIES 420 BAR

HIGH PRESSURE FI TERS HPM SERIES 420 BAR HIGH PRESSURE FI TERS HPM SERIES 4 R HPM is the high pressure filter up to 4.. Pa (4 bar- Psi); the range is composed by different sizes with nominal flow rates up to 4 l/min., available with threaded

More information

Guide book AS 300 G. Waste water filtration unit. Im Geer 20, D Isselburg. Description / Type-No.: AS 300 G Type 523

Guide book AS 300 G. Waste water filtration unit. Im Geer 20, D Isselburg. Description / Type-No.: AS 300 G Type 523 Waste water filtration unit Manufacturer: deconta GmbH Im Geer 20, D - 46419 Isselburg Description / Type-No.: Type 523 Table of contents on Page 1 Introduction 3 2 Basic safety advice 4 2.1 Intended use

More information

ISO/TC 131/SC Pneumatic fluid power Compressed-air filters

ISO/TC 131/SC Pneumatic fluid power Compressed-air filters DRAFT INTERNATIONAL STANDARD ISO/DIS 5782-1 ISO/TC 131/SC 5 Pneumatic fluid power Compressed-air filters Part 1: Main characteristics to be included in suppliers literature and product marking requirements

More information

Modulating liquid level regulators direct operated, for low pressure side types SV 4, 5 and 6 REFRIGERATION AND AIR CONDITIONING.

Modulating liquid level regulators direct operated, for low pressure side types SV 4, 5 and 6 REFRIGERATION AND AIR CONDITIONING. Modulating liquid level regulators direct operated, for low pressure side types SV 4, 5 and 6 REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction.......................................................................................

More information

OHF 1120 HOW THE CONTAMINATION IS MEASURED CONTAMINATION CLASSES ACCORDING TO ISO 4406:1999

OHF 1120 HOW THE CONTAMINATION IS MEASURED CONTAMINATION CLASSES ACCORDING TO ISO 4406:1999 OHF 1120 FILTRATIO I BRIEF Contamination Control in the hydraulic system is a very wide and complex matter; the following is just a short summary. Our Customer Service is at your disposal for any further

More information

WARNING: only use TEFLON tape to seal filter connections. Do not use other types of sealing material or the warranty shall be null and void.

WARNING: only use TEFLON tape to seal filter connections. Do not use other types of sealing material or the warranty shall be null and void. Dear Customer, Thank you for choosing this Filter. Carefully read the in-formation in this manual before installing the filter. Failure to observe the indicated instruction null and voids all warrantees.

More information

Hydraulic fluid power Sequence of tests for verifying performance characteristics of filter elements

Hydraulic fluid power Sequence of tests for verifying performance characteristics of filter elements INTERNATIONAL STANDARD ISO 11170 Third edition 2013-02-15 Hydraulic fluid power Sequence of tests for verifying performance characteristics of filter elements Transmissions hydrauliques Ordre des essais

More information

Float valves Types SV 4, SV 5 and SV 6

Float valves Types SV 4, SV 5 and SV 6 Data sheet Float valves Types SV 4, SV 5 and SV 6 SV 4-6 are for use on the low pressure side as modulating liquid level regulators in refrigeration, freezing and air conditioning systems with ammonia

More information

Nessie Pumps type PAH 2/4/6.3, PAH 10/12.5, PAH 20/25/32 and PAH 50/63/70/80/100

Nessie Pumps type PAH 2/4/6.3, PAH 10/12.5, PAH 20/25/32 and PAH 50/63/70/80/100 Data Sheet Nessie Pumps type PAH 2/4/6.3, PAH 10/12.5, PAH 20/25/32 and PAH 50/63/70/80/100 Introduction PAH 2/4/6.3, PAH 10/12.5, PAH 20/25/32 and PAH 50/63/70/80/100 are pumps designed to supply water

More information

ACCESSORIES LS/520, LC/520 Heavy duty non-return valves 1/ LT1000 Block form flow regulators (uni-directional) 1/8 & 1/4

ACCESSORIES LS/520, LC/520 Heavy duty non-return valves 1/ LT1000 Block form flow regulators (uni-directional) 1/8 & 1/4 ESSORIES LT000 lock form flow regulators (uni-directional) /8 & /4 LT00 lock form flow regulators (bi-directional) /8 & /4 LT70 Quick exhaust valves /8 & /4 LS/50, L/50 Heavy duty non-return valves /4...

More information

Nessie Pumps type PAH 2/4/6.3, 10/ /32 and PAH 50/63/70/80

Nessie Pumps type PAH 2/4/6.3, 10/ /32 and PAH 50/63/70/80 Data Sheet Nessie Pumps type PAH 2/4/6.3, 10/12.5 25/32 and PAH 50/63/70/80 Generally PAH 2/4/6,3, 10/12,5, 25/32 and 50/63/70/80 are pumps designed to supply water flow under high pressure. The pumps

More information

Air Cooler Industry OSCA / OSCAF 0-3

Air Cooler Industry OSCA / OSCAF 0-3 Cooler Industry OSC / OSCF 0- Symbol General The low noise coolers of OSC / OSCF series are mostly used in small and medium hydraulic systems. Compact and efficient they offer high performance with a low

More information

LUBRICATION PUMP Z2 CENTRAL LUBRICATION

LUBRICATION PUMP Z2 CENTRAL LUBRICATION LUBRICATION PUMP APPLICATION Lubrication pumps are used as a source of pressure lubricant in the circuits of two-line central lubrication systems. Pumps can be used for lubrication of high number of lubricated

More information

Product Data Castrol Anvol WG46

Product Data Castrol Anvol WG46 Castrol Anvol WG46 Fire Resistant Hydraulic Fluids Description Castrol Anvol WG is a water glycol fire resistant hydraulic fluid that meets HFC 7th Luxembourg classification and Factory Mutual Category

More information

F64G - Olympian Plus Plug-In System General purpose filter

F64G - Olympian Plus Plug-In System General purpose filter > > Port size: /... 3/ (ISO G/PTF) > > Quick release bayonet bowl > > Effective liquid removal and positive solid filtration > > Large filter element area for minimum pressure drop Technical features Medium:

More information

AIR BLEED VALVES : ST1004 PIPE FLANGE KITS : "F3","F5","F6" SERIES

AIR BLEED VALVES : ST1004 PIPE FLANGE KITS : F3,F5,F6 SERIES AIR BD VAVS : ST04 PIP ANG ITS : "3","5","6" SRIS General Information Pub. C-0 Air Bleed Valves...Page These air bleed valves are designed to use, at the start-up of the pumps, to bleed off the air enclosed

More information

TECHNICAL SPECIFICATION OF HORIZONTAL MILLING MACHINE

TECHNICAL SPECIFICATION OF HORIZONTAL MILLING MACHINE SCOPE: SUPPLY, ERECTION & COMMISSIONING OF HORIZONTAL MILLING MACHINE WITH SPECIFICATIONS AS BELOW : SL. NO. DESCRIPTION OF BHEL REQUIREMENT REQUIRED OFFERED DEVIATION REMARKS 1.0 PURPOSE & WORKPIECE MATERIAL

More information

HIGH EFFICIENCY FILTERS FOR COMPRESSED AIR PURIFICATION. Filtration & System solutions. AIR VIP EvO

HIGH EFFICIENCY FILTERS FOR COMPRESSED AIR PURIFICATION. Filtration & System solutions. AIR VIP EvO HIGH EFFICIENCY FILTERS FOR COMPRESSED AIR PURIFICATION Filtration & System solutions AIR VIP EvO AIR VIP EvO Evolution and quality AIR VIP EvO has been developed to become the new benchmark in the international

More information

Industrial flue gas probes. Instruction manual

Industrial flue gas probes. Instruction manual Industrial flue gas probes Instruction manual 2 1 Contents 1 Contents 1 Contents... 3 2 Safety and the environment... 4 2.1. About this document... 4 2.2. Ensure safety... 4 2.3. Protecting the environment...

More information

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 SECTIONAL TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL 303 BEARINGS 304

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 SECTIONAL TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL 303 BEARINGS 304 CONTENTS Page - SPECIFICATIONS 200 PERFORMANCE RANGE and SELECTION CHART 201 TYPE KEY and CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 40 203 PERFORMANCE CURVE 80 204 - CONSTRUCTIONS 300 SECTIONAL VIEW 300

More information

ACCESSORIES ROTOTEC ACCESSORIES

ACCESSORIES ROTOTEC ACCESSORIES ACCESSORIES 136 136 ACCESSORIES ROTOTEC ACCESSORIES ROTOTEC 137 H H ACCESSORIES Ø Cover THREADED EXTENSION Ø H Ø Cover PP30 300 300 210 55.00 PP35 435 300 300 70.00 PP45 535 300 400 90.00 Ø Application:

More information

Telf : Fax :

Telf : Fax : HYDRAULIC FILTER ACCESSORIES 2/7 MAINTENANCE UNIT FOR FILTER ELEM MENT CHANGE For quick and clean filter element change without oil loss, the Internormen WGR 60 maintenance unit is ideal. Pumping and storing

More information

Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 202 CURVE SPEFICATIONS 203 PERFORMANCE CHART BEST ONE 204 PERFORMANCE CHART BEST ONE VOX 205

Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 202 CURVE SPEFICATIONS 203 PERFORMANCE CHART BEST ONE 204 PERFORMANCE CHART BEST ONE VOX 205 CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 202 CURVE SPEFICATIONS 203 PERFORMANCE CHART 204 PERFORMANCE CHART VOX 205 - CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW

More information

Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 202 CURVE SPEFICATIONS 203 PERFORMANCE CHART BEST ONE 204 PERFORMANCE CHART BEST ONE VOX 205

Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 202 CURVE SPEFICATIONS 203 PERFORMANCE CHART BEST ONE 204 PERFORMANCE CHART BEST ONE VOX 205 CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 202 CURVE SPEFICATIONS 203 PERFORMANCE CHART 204 PERFORMANCE CHART VOX 205 - CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW

More information

TABLE OF CONTENTS

TABLE OF CONTENTS DIVISION 33: SEWER AND SEPTIC SYSTEMS 33 3633 UTILITY SEPTIC TANK DRAINAGE FIELD TABLE OF CONTENTS 33 0000-1 SECTION 33 3633-- UTILITY SEPTIC TANK DRAINAGE FIELD PART 1 - GENERAL 1.1 SUMMARY A. Includes

More information

SEMPELL. High Pressure Steam Bypass Valves - Type 115 ASME.

SEMPELL. High Pressure Steam Bypass Valves - Type 115 ASME. SEMPELL Steam Turbine and Boiler protection at Steam Turbine trip. Steam Turbine bypass to Cold Reheat or Condenser while Boiler/Turbine start-up and shut-down. Features and Benefits Pressure reduction

More information

Line filters LINE FILTERS

Line filters LINE FILTERS Line filters LINE FILTERS 4-40 ALUP Driven by technology. Designed by experience. ALUP Kompressoren has over 90 years of industrial experience. It is our ambition to offer compressed air solutions that

More information

MFR / MFF / MFT. Magnetic Filters and Dirt Traps : PN 40. p max. t max. : +200 C OScrew O thread: G ¼... G 4

MFR / MFF / MFT. Magnetic Filters and Dirt Traps : PN 40. p max. t max. : +200 C OScrew O thread: G ¼... G 4 Magnetic Filters and Dirt Traps measuring monitoring analysing MFR / MFF / MFT OO p max : PN 40 OO t max : +200 C OScrew O tread: G ¼... G 4 OScrew O tread: Rp 1... Rp 2 OFlanges: O DN 50... DN 200 OSolder

More information

Clean Oil. Guide. 100 micrometres Grain of salt. 40 micrometres Naked eye visibility. 70 micrometres Human hair. 3 micrometres OIL

Clean Oil. Guide. 100 micrometres Grain of salt. 40 micrometres Naked eye visibility. 70 micrometres Human hair. 3 micrometres OIL Clean Oil ADDING ENERGY Guide 100 micrometres Grain of salt 0 micrometres Naked eye visibility 70 micrometres Human hair 5 micrometres Pollen micrometres Coal dust micrometres OIL micrometres Bacteria

More information

In-line Twin Pump. Type Series Booklet. Omega DSL

In-line Twin Pump. Type Series Booklet. Omega DSL In-line Twin Pump Type Series Booklet Legal information/copyright Type Series Booklet All rights reserved. The contents provided herein must neither be distributed, copied, reproduced, edited or processed

More information

Page - SPECIFICATIONS SPECIFICATION PUMP 200 SPECIFICATION MOTOR 201 SELCTION CHART TYPE KEY-TYPE PUMP 202 PERFORMANCE CURVE SB

Page - SPECIFICATIONS SPECIFICATION PUMP 200 SPECIFICATION MOTOR 201 SELCTION CHART TYPE KEY-TYPE PUMP 202 PERFORMANCE CURVE SB SUBMERSIBLE MULTISTAGE PUMPS SB 3 CONTENENTS 50 Hz Page - SPECIFICATIONS SPECIFICATION PUMP 200 SPECIFICATION MOTOR 201 SELCTION CHART TYPE KEY-TYPE PUMP 202 PERFORMANCE CURVE SB 3 15-23-30-45 203 - CONSTRUCTIONS

More information

Line Filters Solid, simple, smart. Advanced reliability in compressed air. TECHNOLOGY YOU CAN TRUST

Line Filters Solid, simple, smart. Advanced reliability in compressed air. TECHNOLOGY YOU CAN TRUST Line Filters 7-0 Solid, simple, smart. Advanced reliability in compressed air. AVAILABILITY PARTNERSHIP SERVICEABILITY TECHNOLOGY YOU CAN TRUST RELIABILITY SIMPLICITY AVAILABILITY PARTNERSHIP SERVICEABILITY

More information

GENERAL CONTENTS SECTION I - NUCLEAR ISLAND COMPONENTS

GENERAL CONTENTS SECTION I - NUCLEAR ISLAND COMPONENTS - June 2013 Addendum GENERAL CONTENTS SECTION I - NUCLEAR ISLAND COMPONENTS SUBSECTION "A" : GENERAL RULES SUBSECTION "B" : CLASS 1 COMPONENTS SUBSECTION "C" : CLASS 2 COMPONENTS SUBSECTION "D" : CLASS

More information

Rexroth Oil Cleanliness Booklet

Rexroth Oil Cleanliness Booklet Rexroth Oil Cleanliness Booklet 2 Oil Cleanliness Booklet Introduction Introduction Oil is the central component of any hydraulic system. If a system fails, contamination is one of the major reasons. This

More information

Hydraulic fluids in mobile applications. User information

Hydraulic fluids in mobile applications. User information Hydraulic fluids in mobile applications User information 2 Hydraulic fluids Hydraulic fluids 3 Hydraulic fluids Selection and maintenance of hydraulic fluids are decisive factors for the safe and economic

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 16431 First edition 2012-01-15 Corrected version 2012-03-15 Hydraulic fluid power System cleanup procedures and verification of cleanliness of assembled systems Transmissions

More information

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL and BEARINGS 303

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL and BEARINGS 303 CONTENTS Page - SPECIFICATIONS 200 PERFORMANCE RANGE and SELECTION CHART 201 TYPE KEY 202 CURVE SPECIFICATIONS 203 PERFORMANCE CURVE 40 203 PERFORMANCE CURVE 80 204 - CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING

More information

GESTRA Gravity Circulation Checks and DISCO Non-Return Valves GESTRA DISCOCHECK Dual-Plate Check Valves and DISCO Swing Check Valves

GESTRA Gravity Circulation Checks and DISCO Non-Return Valves GESTRA DISCOCHECK Dual-Plate Check Valves and DISCO Swing Check Valves GESTRA Gravity Circulation Checks and DISCO Non-Return Valves GESTRA DISCOCHECK Dual-Plate Check Valves and DISCO Swing Check Valves A2 Page DISCO Non-Return Valves Gravity Circulation Checks and DISCO

More information

CONA -Universal ANSI / CONA -Connector ANSI

CONA -Universal ANSI / CONA -Connector ANSI CONA -Universal ANSI for quick assembly/disassembly on CONA -Connector or foreign system connectors CONA -Universal ANSI / CONA -Connector ANSI CONA B-Universal ANSI Bimetallic steam trap ANSI CONA M-Universal

More information

Line filters LINE FILTERS

Line filters LINE FILTERS Line filters LINE FILTERS 45-2430 Worthington Creyssensac s heritage Creyssensac was founded in Nanterre (near Paris), France in 934 by Elie Creyssensac and quickly became renowned in the automotive industry

More information

AUTOMATIC AIR VALVES For potable water

AUTOMATIC AIR VALVES For potable water AUTOMATIC AIR VALVES For potable water Page N Air release valve Page N Air release valve avent Page N Air release valve DN 0 / DN 0, DN 150 / DN 00 Page N /1 Page N5 Combined air release valve Page N 5/1

More information

Pneumatic fluid power Compressed air filters. Part 1: Main characteristics to be included in suppliers literature and product marking requirements

Pneumatic fluid power Compressed air filters. Part 1: Main characteristics to be included in suppliers literature and product marking requirements FINAL DRAFT INTERNATIONAL STANDARD ISO/FDIS 5782-1 ISO/TC 131/SC 5 Secretariat: AFNOR Voting begins on: 2017-06-29 Voting terminates on: 2017-08-24 Pneumatic fluid power Compressed air filters Part 1:

More information

The World s Most Versatile Filter System

The World s Most Versatile Filter System The World s Most Versatile Filter System Full-flow filtration systems By-pass filtration systems Water Based Fluids Process Fluids Heating oils Turbine oils Bioethanol Hippo Filter Biodiesel Kerosene Diesel

More information

Microfil GP. Range. Validation Guide. World Class Filtration Solutions

Microfil GP. Range. Validation Guide. World Class Filtration Solutions Microfil GP Range Validation Guide World Class Filtration Solutions Contents Microfil GP Range Validation Guide Introduction 3 - Construction Microfil GP Materials of Construction 4 - FDA Approval - Dimensions

More information

Method for estimating contamination factor, η c, based on lubricant cleanliness

Method for estimating contamination factor, η c, based on lubricant cleanliness Method for estimating contamination factor,, based on lubricant cleanliness A more detailed estimation of for oil or grease lubrication is based on: oil cleanliness level or oil ilter rating grease cleanliness

More information

Walter Stauffenberg GmbH & Co. KG

Walter Stauffenberg GmbH & Co. KG Return Line Filter SRFL-S/D Australia Stauff Corporation (Pty.) Ltd. P.O.Box 227, 24-2 Doyle Avenue, Unanderra Wollongong, N.S.W 252 AUSTRALIA Tel: +1 2 42 71 18 77 Fax: +1 2 42 71 84 2 Brazil Stauff Brasil

More information

Contents EN 14015:2004 (E) page

Contents EN 14015:2004 (E) page Contents page Foreword... 11 1 Scope... 12 2 Normative references... 13 3 Terms, definitions, symbols and abbreviations... 15 3.1 Terms and definitions... 15 3.2 Symbols... 19 3.3 Abbreviations... 21 4

More information

The Aqua Flo range of filters and replacement cartridges improves water quality in the home, farm or business. Requiring no special tools, Aqua Flo

The Aqua Flo range of filters and replacement cartridges improves water quality in the home, farm or business. Requiring no special tools, Aqua Flo Filters The Aqua Flo range of filters and replacement cartridges improves water quality in the home, farm or business. Requiring no special tools, Aqua Flo filters are easily installed and cartridge replacement

More information

Engineering Excellence

Engineering Excellence Energy Saving Compressed Air Filters NGF SERIES 20 to 1500 scfm (34 to 2459 nm 3 /h) Engineering Excellence SPX is a place where innovation is valued, and the real needs of business are understood. We

More information

energy SPARE PARTS LIST - September

energy SPARE PARTS LIST - September energy SPARE PARTS LIST - September 20 - WESTEN HOW TO READ THE SPARE PARTS CATALOGUE In the spare part catalogue, after the exploded diagrams, there are the components lists of the boilers; this is the

More information

Dirty paper take up and filter cake stripper for separation of paper and waste are optional.

Dirty paper take up and filter cake stripper for separation of paper and waste are optional. K 452 World-wide the most flexible filtration system - ully automatic filtration over filter paper ecause of the possibility of using different filter papers, the desired effects can be achieved. irty

More information

DUST EXTRACTION SYSTEMS

DUST EXTRACTION SYSTEMS DUST EXTRACTION SYSTEMS SAFETY EFFICIENCY RELIABILITY These are the main characteristics RUPES takes into consideration when designing and building the full range of dust extraction systems. The result

More information

Filtration Products. Fluid purifier systems and oil service equipment

Filtration Products. Fluid purifier systems and oil service equipment Filtration Products Fluid purifier systems and oil service equipment Eaton combines sales, engineering, manufacturing, customer service and technical sales support into one focused business provide customers

More information

CONA -Universal / CONA -Connector

CONA -Universal / CONA -Connector CONA -Universal for quick assembly/disassembly on CONA -Connector or foreign system connectors CONA -Universal / CONA -Connector CONA B-Universal Bimetallic steam trap (BR 604) BR 604 Page CONA M-Universal

More information

Stainless Steel Products Products for use in offshore, instrumentation, and compatiblity applications.

Stainless Steel Products Products for use in offshore, instrumentation, and compatiblity applications. Section 16 Stainless Steel Products Products for use in offshore, instrumentation, and compatiblity applications. Contents F22 General Purpose Stainless Steel Filter 1/2" Port Size....................................LE-16-2

More information

WEGO3 Cooling and filter system

WEGO3 Cooling and filter system The Professional Choice in Fluid Management WEGO3 Cooling and filter system The Olaer Group is a global player specialising in innovative, efficient system solutions for temperature optimisation and energy

More information

NPSH S TRAINER PTC CORROSION RESISTANT IEC close-coupled BASEPLATE in-line MACHINED TENSI

NPSH S TRAINER PTC CORROSION RESISTANT IEC close-coupled BASEPLATE in-line MACHINED TENSI LER half open impeller SILENT spacer coupling ATEX BORN TO RESIST CORROSION compac O 2858 BACK PULL-OUT bare shaft HiEff 3D impeller solid liquid end materials S EL etic drive Viton PEEK flexible diaphragm

More information

VALVES. Prospector Series Poppet Valves 1/4" to 2" Air Pilot Actuated 2/2, 3/2, & 4/2 Inline Valves

VALVES. Prospector Series Poppet Valves 1/4 to 2 Air Pilot Actuated 2/2, 3/2, & 4/2 Inline Valves 2 High flow - Cv of 1.2 to 49.5 Durable, robust construction Two mounting styles: inline or subbase 1/4" to 2" ports (SPP or PTF threads) Wide range of ir Pilot Operators available Four functional types:

More information

New filter materials for hydraulic systems: Longer service life and reduced operating costs

New filter materials for hydraulic systems: Longer service life and reduced operating costs New filter materials for hydraulic systems: Longer service life and reduced operating costs Bosch Rexroth is introducing a new generation of filter media, using state-of-the-art materials and advanced

More information

Materials : Ductile iron body EN GJS 500-7

Materials : Ductile iron body EN GJS 500-7 Certificate 3.1 Size : Ends : Min Temperature : Max Temperature : DN 40 to DN 1000 PN10/16 flanges - 10 C + 70 C with EPDM wedge Max Pressure : 16 Bars up to DN400, 10 bars over Specifications : Non rising

More information