1 EnPC Intrans International Conference, November 15, 2016 MEASUREMENT AND VERIFICATION OF SAVINGS MEASUREMENT AND VERIFICATION TOOLS Spiros Metallinos Regulatory Authority for Energy, Greece

2 EnPC Intrans International Conference, November 15, 2016 Introduction The Regulatory Authority for Energy ( RAE ) building is the first in Greece to have an EMS according to ISO standard installed, based on measurement and verification procedure for the energy savings, dated February The measurement and verification procedure followed is according to the International Performance Measurement and Verification Protocol (hereafter referred to as IPMVP) which is not a requirement of the ISO standard itself. RAE s ISO energy management system which includes this measurement and verification procedure according to IPMVP is certified by the independent certification body TUV Austria Hellas.

3 EnPC Intrans International Conference, November 15, 2016 List of sections 1. Building and climate characteristics 2. Linking ISO with the IPMVP and ASHRAE Guidelines 3. Presentation of the adopted IPMVP option 4. Challenges and solutions 5. Natural gas regression model 6. Savings and uncertainty calculations 7. Review and conclusions 8. Questions

4 SECTION 1: Building and climate characteristics Page 1/47 The RAE Building The Headquarters of the Regulatory Authority for Energy [RAE] is located in the center of Athens, at Piraeus Avenue 132. The surface area of the building is: m² (from the 1 st to the 7 th floor) m² (2 basement levels) 85 m² (ground floor) It comprises: 1. Heating (hydronic network feeding 251 FCUs and heated by two natural gas burners, 543 kw each) 2. AC-Air conditioning (hydronic network fed by two chillers, 451 kw each) 3. Ventilation (pre-climatised air with m 3 /h total fresh air volume, supplied by two AHUs) 4. Lighting 5. IT-Data Center 6. Devices

5 SECTION 1: Building and climate characteristics Page 2/47 Climate Characteristics The city of Athens has a hot-summer Mediterranean climate: The dominant feature of Athens' climate is alternation between prolonged hot and dry summers and mild winters with moderate rainfall. The RAE building has AC needs (heating and cooling), which are related to an area equal to m². For the implementation of the weather calculations of this study we used weather data from the NASA database that is provided freely by a Canadian Government software named RETSCREEN

6 SECTION 2: Linking ISO with the IPMVP and ASHRAE Guidelines Page 3/47 The Energy Baseline - ISO According to paragraph 3.6 for the Energy Baseline: it reflects a specified period of time. it gives us a quantitative reference providing a basis for comparison of energy performance. it can be normalized using variables which affect energy use and/or consumption, e.g. production level, degree days (outdoor temperature), etc. it is also used for calculation of energy savings, as a reference before and after implementation of energy performance improvement actions. ISO does not describe how to normalize the Energy Baseline

7 SECTION 2: Linking ISO with the IPMVP and ASHRAE Guidelines Page 4/47 The Energy Baseline - ISO According to paragraph 4.4.4: The organization shall establish an Energy Baseline(s) using the information in the initial energy review, considering a data period suitable to the organization's energy use and consumption. Changes in energy performance shall be measured against the Energy Baseline(s). Adjustments to the Energy Baseline(s) shall be made in the case of one or more of the following: EnPIs no longer reflect organizational energy use and consumption, or there have been major changes to the process, operational patterns, or energy systems, or according to a predetermined method. The Energy Baseline(s) shall be maintained and recorded.

8 SECTION 2: Linking ISO with the IPMVP and ASHRAE Guidelines Page 5/47 Use of the IPMVP Given that ISO does not describe how to normalize the baseline we used the IPMVP (International Performance Measurement and Verification Protocol) in order to implement a robust M&V plan ex ante. Is the IPMVP compatible with ISO 50001? The answer is in D-11 of IPMVP under the title : Energy Users Seeking ISO Certification. IPMVP: The management methods required under ISO focus on managing total facility utility costs. IPMVP s Options C and D (Whole Facility and Calibrated Simulation) describe methods useful for this purpose, even if no savings are being sought. IPMVP cautions on the challenges of detecting small changes in whole facility utility energy use data. IPMVP offers both general guidance and specific guidance on how large total facility energy use changes must be to be reportable with any statistical validity.

9 SECTION 2: Linking ISO with the IPMVP and ASHRAE Guidelines Page 6/47 IPMVP and ASHRAE Guideline 14 Is there any connection between IPMVP and ASHRAE (American Society of Heating, Refrigerating and Air-Conditioning Engineers) Guideline 14 (Guideline Measurement of Energy and Demand Savings)? ASHRAE Guideline 14: 1. provides complementary details for IPMVP. 2. has many of the same original authors as IPMVP. 3. provides technical details following many of the same concepts of IPMVP (but it does not use the same Option names as IPMVP.). 4. is a unique and useful resource for M&V professionals around the world. IPMVP: refers to ASHRAE Guideline 14 for practical details of the M&V methodology.

10 SECTION 2: Linking ISO with the IPMVP and ASHRAE Guidelines Page 7/47 ISO 50001, IPMVP and ASHRAE Guideline 14 ISO Provides general guidance about energy saving IPMVP Provides general guidance about M&V ASHRAE Guideline 14 Provides practical details about M&V By using the above mentioned documents we started forming our M&V procedure

11 SECTION 3: Presentation of the adopted IPMVP option Page 8/47 The Baseline concept A. We have two periods: 1. The Baseline Period (before any retrofits) 2. The Reporting Period(s) (after any retrofits) B. With data from Baseline period, we develop a mathematical equation that correlates the energy consumption of the building with independent variable(s) that cause this consumption: C. The mathematical model will give different energy use or demand as each period has different independent variables (values) and the energy performance of the building after the ECM is expected to be improved. We refer to this mathematical equation of the Baseline Period as Baseline model

12 SECTION 3: Presentation of the adopted IPMVP option Page 9/47 The Baseline concept Savings = Adjusted Baseline Energy Reporting Period Measured Energy = (Baseline Energy Reporting Period Measured Energy ) ± Adjustments

13 SECTION 3: Presentation of the adopted IPMVP option Page 10/47 Which Baseline Period? The Baseline Period should be established to: Represent all operating modes of the facility. This period should span a full operating cycle from maximum energy use to minimum. Fairly represent all operating conditions of a normal operating cycle. Include only time periods for which all fixed and variable energy-governing facts are known about the facility. Coincide with the period immediately before commitment to undertake the retrofit.

14 SECTION 3: Presentation of the adopted IPMVP option Page 11/47 Savings calculation According to IPMVP there are two approaches to calculate savings: Savings (Energy and Cost savings) Avoided Energy Use or Avoided Cost Stated under conditions of the Reporting Period Normalized Savings Stated under fixed or normal conditions Savings = (Baseline Energy Reporting Period Energy) ± Routine Adjustments ± Non-Routine Adjustments

15 SECTION 3: Presentation of the adopted IPMVP option Page 12/47 The Adjusted Baseline Energy The Adjusted Baseline Energy is defined as the Baseline Energy plus any routine adjustments needed to adjust it to the conditions of the reporting period. The Adjusted Baseline Energy is normally found by first developing a mathematical model which correlates actual baseline energy data with appropriate independent variable(s) in the baseline period. Each reporting period s independent variable(s) are then inserted into this baseline mathematical model to produce the Adjusted Baseline Energy use. An independent variable is a parameter that is expected to change regularly and have a measurable impact on the energy use of a system or facility. For example, a common independent variable governing building energy use is outdoor temperature.

16 SECTION 3: Presentation of the adopted IPMVP option Page 13/47 Summary of Baseline terms Baseline Period = Reference period before any energy interventions take part in a building Energy Baseline / Baseline Energy = Quantitative reference providing a basis for comparison of energy performance Adjusted Baseline Energy = Baseline Energy plus any routine adjustments needed to adjust it to the conditions of the reporting period Baseline Energy Equation / Baseline Equation = Mathematical expression that correlates the energy consumption of the building with independent variables that cause this consumption Baseline Method = Method used to predict the energy consumption of a building for a certain period in the hypothetical case that energy interventions didn t occurred Baseline = In general, the term Baseline can be associated with the term Reference

17 SECTION 4: Challenges and solutions Page 14/47 Facts Baseline period In the RAE building occurred the following events: In 2010 and in the first semester of 2011 there have been lots of changes in the patterns of consumption such as alteration of setpoints, facility working hours etc as well as there was not an acceptable thermal comfort. In 2011 RAE s Board decided to implement an EMS in line with ISO which included a multifaceted energy management program affecting many systems in the building. In summer 2011 the building started to operate normally and the building management team set the building in a way that ensured thermal comfort to the occupants. During 2012 the EMS was designed and the first energy review was commissioned in October In 2013, the M&V procedure was updated using the same baseline data but in line with IPMVP and Ashrae Guideline 14 methodology.

18 SECTION 4: Challenges and solutions Page 15/47 1) Which option to follow? The IPMVP provides four options for determining savings (A, B, C and D): A. Retrofit Isolation: Key Parameter Measurement B. Retrofit Isolation: All Parameter Measurement C. Whole Facility D. Calibrated Simulation

19 SECTION 4: Challenges and solutions Page 16/47 1) Which option to follow? We decided to use the Whole Facility option (C). This option is based on utility bills that assumed to have zero uncertainty. Some of the reasons for this decision of option C are the following: 1. Savings calculation at the facility level. 2. No calibration program = no reliable data 3. Human resources and money for a sophisticated A, B or even more D option. 4. No plan for major changes to the premises and staff for years to come. 5. Α multifaceted energy management program planned 6. IPMVP reporting requirement : Savings to be expressed in energy and monetary units. 7. IPMVP s Retrofit Isolation Options A and/or B are appropriate management tools for specific energy efficiency projects but they cannot be correlated with Whole Facility utility bills.

20 SECTION 4: Challenges and solutions Page 17/47 2) Which are the independent variables that have impact to the NG consumption? IPMVP states that in order to judge the relevance of independent variables it is required both experience and intuition. The associated t-statistic is one way of confirming the relevance of particular independent variables included in a model. Experience in energy analysis for the type of facility involved in any M&V program is necessary to determine the relevance of independent variables.

21 SECTION 4: Challenges and solutions Page 18/47 2) Which are the independent variables that have impact to the NG consumption? To identify the significance of individual coefficients, t-statistics are used. Tstatistics are the ratio of the coefficient estimate divided by the standard error of the estimate. b t SEb For a coefficient to be statistically meaningful, the absolute value of its t-statistic must be at least 2.0. Under no circumstances should a variable be included in a regression if the standard error of its coefficient estimate is greater than half the magnitude of the coefficient (even when including a variable that increases the R 2 ).

22 SECTION 4: Challenges and solutions Page 19/47 2) Which are the independent variables that have impact to the NG consumption? In order to improve the t-statistic result we should: Select independent variable(s) with the strongest relationship to energy Select independent variable(s) whose values span the widest possible range (if X does not vary at all in the regression model, b cannot be estimated and the t- statistic will be poor) Gather and use more data points to develop the model Select a different functional form for the model, for example, one which separately determines coefficient(s) for each season in a building that is significantly affected by seasonal weather changes.

23 SECTION 4: Challenges and solutions Page 20/47 2) Which are the independent variables that have impact to the NG consumption? Given the instruction of the textbooks we did not included the occupancy which remained stable during the baseline period and proved to have a t-statistic < 2. The only significant variable detected was the DD (Degree Days) for both electricity and Natural gas models with the exception of the low price zone electricity model.

24 SECTION 4: Challenges and solutions Page 21/47 3) Where do we find reliable weather data? A simple definition for DD (Degree Days): DD are a measurement designed to measure the demand for energy needed to heat/cool a building. DD are derived from measurements of outside air temperature. The heating/cooling requirements for a given building at a specific location are considered to be directly proportional to the number of DD at that location.

25 SECTION 4: Challenges and solutions Page 22/47 3) Where do we find reliable weather data? 1. In order to calculate the DD we need reliable weather data as ASHRAE Guideline 14 states. 2. We had temperature sensors and a lot of data in our databases but they were not reliable since there was not a calibration plan. 3. IPMVP advises: Where monthly energy measurements are used, weather data should be recorded daily so it can be matched to the actual energy-metering reading dates. For monthly or daily analysis, government published weather data is usually the most accurate and verifiable. When analyzing the response of energy use to weather in mathematical modeling, daily mean temperature data or DD (Degree Days) may be used.

26 SECTION 4: Challenges and solutions Page 23/47 3) Where do we find reliable weather data? In our estimations we used weather data from the NASA database that is provided freely by a Canadian Government software named RETSCREEN, thus reducing the cost of M&V procedures

27 SECTION 4: Challenges and solutions Page 24/47 4) Which base-point to use in order to calculate the DD? ASHRAE Fundamentals describes the procedure of modeling utility bill data: 1. To obtain the equation coefficients through regression, the utility bills must be normalized by the length of the time interval between utility bills. This is equivalent to expressing all utility bills, degree-days, and other independent variables by their daily averages. 2. Appropriate modeling software is used in which values are assumed for heating and cooling balance points. From these, the corresponding heating and cooling degree-days for each utility bill period are determined. 3. Repeated regression is done till the regression equation represents the best fit to the meter data. 4. The model coefficients are then assumed to be tuned. Some programs allow direct determination of these optimal model parameters without the user s manual tuning of the parameters.

28 SECTION 4: Challenges and solutions Page 25/47 4) Which base-point to use in order to calculate the DD? IPMVP states that any reference temperature may be used for recording DD (Degree Days), though it is usually chosen to reflect the temperature at which a particular building no longer needs heating or cooling. Since the only significant variable is the weather, by implementing the above methodology we calculated the appropriate balance point or reference temperature for the DD. After this tuning we developed the regression model that best fits to the metered data.

29 SECTION 4: Challenges and solutions Page 26/47 5) IPMVP requires savings to be expressed in energy and monetary units The pricing policy of Natural Gas and Electricity utility bills makes difficult to associate the energy consumption with monetary units. Tariff schedule for Natural Gas: Fixed demand tariff normalized by the length of the billing period Commodity tariff (consumption) multiplied by the higher calorific value (HCV) for each month or period Taxes and levies on consumption VAT Tariff schedule for Electricity: Competitive charges Regulated charges High pricing zone Transmission system charges Low pricing zone Distribution system charges Demand within peak period Charges for the reduction of gas emissions Demand during the off-peak period Taxes and levies Cos(ф)

30 SECTION 4: Challenges and solutions Page 27/47 5) IPMVP requires savings to be expressed in energy and monetary units We thoroughly examined the tariff schedule of RAE Electricity and Natural Gas suppliers and we decided to establish the following models in order to be able to calculate the appropriate tariff drivers (parameters) in the reporting period: For the Electricity we established five mathematical models: High pricing zone Low pricing zone Demand within peak period Demand during the off-peak period For the Natural Gas we established one model since there is not up to date differed charge for peak and off-peak periods.

31 SECTION 5: Natural Gas regression model Page 28/47 Natural Gas consumption Heating Degree Days (HDD 18,77 ) and Natural Gas consumption (utility bills) Period Index Starting Date Ending Date Number of Days Total HDD (Kd) Total Consumption (kwh) P1 24/9/ /11/ , ,65 P2 24/11/ /1/ , ,06 P3 26/1/ /3/ , ,54 P4 24/3/ /5/ , ,92 P5 24/5/ /7/ ,00 0 P6 24/7/ /9/ ,00 0 SUM 1.082, ,17

32 SECTION 5: Natural Gas regression model Page 29/47 Natural Gas Baseline Equation After the preparatory procedure, where we examined the independent variables that have impact to the NG consumption, we concluded that the only independent variable that have measurable impact is the HDD. HDD was proved to be statistically significant variable as t-statistic was roughly 36. To establish the mathematical model for the Natural Gas Consumption of our building we had to correlate the consumption with the heating degree days (X) with the Natural Gas consumption. Υ = α 0 + α 1 Χ Where: Υ : Natural Gas consumption X : Heating Degree Days (HDD)

33 SECTION 5: Natural Gas regression model Page 30/47 Natural Gas Baseline Equation This equation simulates the Natural Gas consumption by using the method of least squares. The form of the regression models can be either purely statistical or loosely based on some basic engineering formulation of energy use in the building The identified model coefficients are such that no (or very little) physical meaning can be assigned to them. If we try to give to these constants physical meaning we could put it as follows: The constant α 0 (intercept) reflects the basic energy consumption (or base load) under normal operation without the influence of any kind of variables that trigger consumption. The constant α 1 (slope) is a constant that, being multiplied with the variable which is the heating degree days, results to the energy that is consumed when there are HDD. Υ = α 0 + α 1 Χ Where: Υ : Natural Gas consumption X : Heating Degree Days (HDD)

34 SECTION 5: Natural Gas regression model Page 31/47 Calculation of the Natural Gas Baseline Equation IPMPV gives examples of monthly model but measurements from our Natural Gas provider took place roughly every two months in the baseline period. The meter readings schedule was amended by our supplier after the Baseline period ( ) and it was announced (2012) that it would take place henceforth roughly every month. In order to eliminate Net Bias Error Due to Data Length Variation we used a more sophisticated regression technique on the basis that the ordinary least squares technique is a simplification of a more general case, when all data points are equally weighted. Since every data point covered less/ longer time period than others, it meant that it should carry more or less weight. Following Ashrae Guideline 14 procedures we regressed the average daily utility consumption data against billing period Degree Days using the appropriate weights (weighted regression).

35 SECTION 5: Natural Gas regression model Page 32/47 Calculation of the Natural Gas Baseline Equation Our two parameters α 0 and α 1 are derived from the following equations using the weighted regression: a 0 ( WY ( W WX 2 ) ( WX 2 ) ( WX WX) WXY) 2 a 1 ( W ( W WXY) ( WX 2 ) ( WY WX) WX) 2

36 SECTION 5: Natural Gas regression model Page 33/47 Baseline Analysis Results Given the above mentioned facts the Baseline Equation related to the Natural Gas: was assessed on mean daily values was detected throughout the reference period since no energy interventions occurred in the building is given by the equation: Υ = 194, ,6x Where: Y = average Natural Gas consumption (kwh/day) X = average Heating Degree Days (Kd/day)

37 SECTION 5: Natural Gas regression model Page 34/47 Baseline Analysis Results Heating Degree Days (HDD 18,77 ) and Natural Gas consumption (utility bills) Period Index Starting Date Ending Date Number of Days Total HDD (Kh) Average HDD (Kh/Day) Total Consumption (kwh) Average Consumption (kwh/day) P1 24/9/ /11/ ,83 2, , ,85 P2 24/11/ /1/ ,74 6, , ,79 P3 26/1/ /3/ ,23 7, , ,44 P4 24/3/ /5/ ,17 1, ,92 601,82 P5 24/5/ /7/ P6 24/7/ /9/ SUM 1.082, ,17 Following ASHRAE Guideline 14 procedures we regressed the average daily utility consumption data against billing period Degree Days using the appropriate weights (weighted regression) for a twelve month period without including the period from 24/5/2012 to 24/9/2012 since heating is by turned off default.

38 SECTION 5: Natural Gas regression model Page 35/47 Model Evaluation IPMVP provide us with three tests to evaluate our model: 1. Coefficient of Determination (R 2 ) R (ˆ y y) 2 2 i 2 ( yi y) 2. Standard Error of the Estimate (SE, CVRMSE & MBE) SE yˆ (ˆ yi yi) n p 1 2 CVRMSE ( y yˆ i i) /( n p) y MBE (ˆ Y Yi ) n 3. T-statistic t statistic b SE b Yˆ t SE Y ˆ Minimum Requirements for Compliance with Guideline 14 : For the three performance paths, the level of uncertainty shall not be greater than 50% of the annual reported savings (at the 68% confidence level).

39 SECTION 5: Natural Gas regression model Page 36/47 Model Evaluation Results of the calculated regression on Natural Gas Baseline REGRESSION RESULTS Natural Gas Validation Criteria R 2 0,998 > 0,75 t-statistic CDD or HDD 36,88 > 2 t-statistic intercept 2,82 > 2 STANDARD ERROR 3343,8 the lower the better CV(RMSE) 0,0465 <0,25 (ASHRAE) The methodology applied to verify the energy savings is more important than the absolute energy saving results

40 SECTION 6: Savings and uncertainty calculations Page 37/47 Savings The general equation for savings calculation is: Savings = (Baseline Energy Reporting Period Energy) ± Routine Adjustments ± Non-Routine Adjustments The regression model for the daily consumption of Natural gas is: Y = 354,6 X +194,2 We can now calculate the energy we would have consumed if we had not taken any ECMs in the reporting period by inserting the mean daily HDDs of the reporting period prior to non routing adjustments.

41 SECTION 6: Savings and uncertainty calculations Page 38/47 1 st Reporting period Begin End Billed Energy Daily Actual Energy Days Total HDD 18,77 Aver. HDD Modeled Monthly Energy 1st floor Energy Savings kwh /kwh Savings 25/9/ /11/ ,69 229, ,7 0, , ,05 0,08 650,79 23/11/ /1/ , , ,78 5, , ,21 0, ,55 24/1/ /2/ , , ,31 6, , ,46 0, ,41 23/2/ /3/ , , ,78 5, , ,66 0, ,18 27/3/ /4/ ,94 440, ,3 3, , ,18 0, ,41 23/4/ /5/ ,09 12, ,51 0, , ,04 0,08 547,66 Total , ,00

42 SECTION 6: Savings and uncertainty calculations Page 39/47 2 nd Reporting period Begin End Billed Energy Daily Actual Energy Days Total HDD 18,77 Aver. HDD Modeled Monthly Energy 1st floor Energy (estimation) Savings kwh /kwh Savings 26/9/ /10/ ,09 0, , ,53 0,07 520,70 25/10/ /11/ ,40 248, ,61 0, , , ,3 0,07 476,89 27/11/ /12/ , , ,88 5, , , ,66 0, ,86 24/12/ /1/ , , ,33 4, , , ,58 0, ,65 28/1/ /2/ , , ,95 5, , , ,84 0, ,50 25/2/ /3/ , , ,68 5, , , ,65 0, ,69 25/3/ /4/ ,67 549, ,96 3, , , ,58 0, ,46 26/4/ /5/ ,99 1, , ,71 0, ,73 Total , ,00

43 SECTION 6: Savings and uncertainty calculations Page 40/47 3 rd Reporting period Begin End Billed Energy Daily Actual Energy Days Total HDD 18,77 Aver. HDD Modeled Monthly Energy 1st floor Energy Savings kwh /kwh Savings 25/9/ /10/ , ,92 0,08 437,76 25/10/ /11/ ,36 602, ,81 1, , , ,64 0,08 646,25 25/11/ /12/ ,29 967, ,84 3, , ,98 0, ,83 24/12/ /1/ , , ,33 6, , , ,44 0, ,44 28/1/ /2/ , , ,33 7, , , ,23 0, ,91 25/2/ /3/ , , ,84 5, , , ,58 0, ,97 27/3/ /4/ ,77 674, ,14 3, , , ,56 0, ,26 29/4/ /5/ ,77 0, , ,91 0,07 587,40 Total , ,00

44 SECTION 6: Savings and uncertainty calculations Page 41/47 Uncertainty Every statistical model have some degree of uncertainty. What level of uncertainty is acceptable and how do we estimate it? IPMVP states that savings are deemed to be statistically valid if they are large relative to the statistical variations. If the variance of the baseline data is excessive, the unexplained random behavior in energy use of the facility or system is high, and any single savings determination is unreliable. The standard error of the baseline is calculated by the formula: SE ( Y i Yˆ) n , 92 n In order to be in line with the IPMVP requirement that savings need to be larger than twice the standard error of the baseline value we should exceed ,83 kwh savings in Natural Gas consumption. 2

45 SECTION 6: Savings and uncertainty calculations Page 42/47 Uncertainty SE ( Y i Yˆ) n 1 n , 92 Savings in all periods exceed the limit of ,83 kwh. Savings of the three Reporting periods in energy and monetary units Period Begin End Savings kwh Savings 1st Reporting period 25/9/ /9/ , ,00 2nd Reporting period 26/9/ /9/ , ,00 3rd Reporting period 25/9/ /9/ , ,00 Total , ,00

46 SECTION 6: Savings and uncertainty calculations Page 43/47 Energy Related Interventions in the building Title of intervention Date of commissioning To Reduce the Natural Gas consumption Ventilation Reduction: Redesign ventilation in 2 fresh air AHU 4/10/2012 Adjustments in automation to introduce free and night cooling in 2 fresh air AHU 4/10/2012 Improvement in the boilers and chillers automation sequence 12/11/2012 Geothermal use of phreatic well for fresh air preheating, reduction of water flow 11/07/2015 To Reduce the Electricity consumption Change in the schedule of the building s facilities: Lightning, Ventilation, Air handlers 4/11/2012 Intervention in the closed control unit plenary CCU-S18 in the plenary room 19/06/2012 Intervention in the electric boards of the stairwells 05/07/2012 Intervention in the lighting of the -5 basement garage, with control via motion detectors 29/07/2012 Ventilation Reduction: Redesign ventilation in 2 fresh Air handlers 10/10/2012 Intervention in building corridors lighting 12/02/2015

47 SECTION 7: Review and conclusions Page 44/47 Review The statistical criteria of the verification procedure used to prove the reported energy savings give excellent results since all requirements are highly satisfied. To achieve the presented savings, a number of low cost interventions has been implemented in the building, with a payback period of 1-5 years. The said savings are verified via the IPMVP tool and are as follows: The cumulative total real energy savings for the two-year period from 1/10/2013 to 30/9/2015 were ,30 kwh el+th or energy consumption savings up to 28,76%, compared to the normalized baseline data. The cumulative overall savings in monetary units for the same two-year period reached the amount of ,62 or 25,37% savings in monetary units, compared to the normalized baseline data. Concerning the uncertainty, the Natural Gas energy savings uncertainty of the 3 rd performance period, for instance, was 17,29% with confidence level 95% when the savings were calculated to be 48,58% compared to the normalized baseline.

48 SECTION 7: Review and conclusions Page 45/47 Conclusions The engineering techniques TAB, RD and MTB as well as the holistic Energy Management can give important energy savings. RAE s building case shows that the EPCs potential market in buildings can rely on low cost interventions and operate on existing commercial energy saving methodologies, as well as on verification procedures of the energy savings that allow for billing of these savings to be accurately measured by third parties for the said TAB techniques. For the future, until 2020, the Authority Management has set an ambitious target to reduce the building energy consumption down to 240 kwh/m 2 /y in EP terms, in line with the suggested value for the overall energy consumption in NZEB Mediterranean buildings. TAB = Testing Adjusting Balancing RD = Re-Design MTB = Measuring, Targeting and Benchmarking

49 SECTION 8: References Page 46/47 References IPMVP 2012, January 2012, International Performance Energy Measurement and Verification Protocol, USA EVO Efficiency Valuation Organization BPA - Bonneville Power Administration Regression for M&V - Measurement and Verification, September 2011, Reference Guide, Version 1.0 Greek Regulation for Energy Inspections (D6/Β/OIK 11038/FEK 1526/1999), 1999 NSW Government, December 2012, Measurement and Verification Operation Guide, Whole Building Applications, Office of Environment and Heritage ASHRAE, 2012, «Performance Measuring Protocol, a Best Practice Guide» ASHRAE, 2002, ASHRAE Guideline «Measurement of Energy and Demand Savings»

50 SECTION 8: References Page 47/47 References M. Karagiorgas, A. Adamopoulos, S. Metallinos, V. Georgiopoulos, G. Anastasopoulos, D. Zacharias, A&B Enreprise, Athens, Greece, Regulatory Authority for Energy, Athens, Greece, «Energy Saving Verification for an ISO in the RAE building», 3rd International Conference ENERGY in BUILDINGS 2014, EinB2014, pp , ASHRAE and ΤΕΕ, Athens Ledra Marriott, November 2014

51 SECTION 9: Questions MEASUREMENT AND VERIFICATION TOOLS Spiros Metallinos, Speaker Regulatory Authority for Energy, Greece ANY QUESTIONS?

7 Measurement and Verification for Generic Variable Loads

7 Measurement and Verification for Generic Variable Loads 7 Measurement and Verification for Generic Variable Loads 7 Measurement and Verification for Generic Variable Loads 7.1 Overview Projects that improve the efficiency of end-uses that exhibit variable energy

More information

ROADMAP TOWARDS NEARLY ZERO ENERGY SPORT BUILDINGS

ROADMAP TOWARDS NEARLY ZERO ENERGY SPORT BUILDINGS ROADMAP TOWARDS NEARLY ZERO ENERGY SPORT BUILDINGS Neuza Rosa neuza.rosa@jesusferreira.pt Final Dissemination Event 21 February 2017, Brussels Topics What is a Nearly Zero Energy Sport Building? Steps

More information

Measurement & Verification for Performance Contracts Through Rebuild Colorado. January Rebuild Colorado

Measurement & Verification for Performance Contracts Through Rebuild Colorado. January Rebuild Colorado Measurement & Verification for Performance Contracts Through Rebuild Colorado January 2005 Rebuild Colorado A Program of the Governor's Office of Energy Management and Conservation 225 East 16th Avenue

More information

Energy savings reporting and uncertainty in Measurement & Verification

Energy savings reporting and uncertainty in Measurement & Verification Australasian Universities Power Engineering Conference, AUPEC 2014, Curtin University, Perth, Australia, 28 September 1 October 2014 1 Energy savings reporting and uncertainty in Measurement & Verification

More information

M&V Fundamentals & the International Performance Measurement and Verification Protocol

M&V Fundamentals & the International Performance Measurement and Verification Protocol M&V Fundamentals & the International Performance Measurement and Verification Protocol What is M&V? Measurement & Verification (M&V) is the process of using measurements to reliably determine actual saving

More information

ManagingEnergy.com. Overview of ASHRAE Guideline (American Society of Heating, Refrigerating and Air-Conditioning Engineers)

ManagingEnergy.com. Overview of ASHRAE Guideline (American Society of Heating, Refrigerating and Air-Conditioning Engineers) ManagingEnergy.com Overview of ASHRAE Guideline 14-2002 (American Society of Heating, Refrigerating and Air-Conditioning Engineers) Measurement of Energy and Demand Savings Measuring Energy Savings To

More information

Methodologies for Determining Persistence of Commissioning Benefits

Methodologies for Determining Persistence of Commissioning Benefits Methodologies for Determining Persistence of Commissioning Benefits David E. Claridge Energy Systems Laboratory Texas A&M University System College Station, TX Abstract: Studies on the persistence of commissioning

More information

Project Measurement and Verification Procedures

Project Measurement and Verification Procedures Project and Verification Procedures 1) Introduction The objective of measurement and verification (M&V) activities at the Project level is to confirm that the Measures that are supported by the Retrofit

More information

Small-scale Methodology AMS-III.AE.: Energy efficiency and renewable energy measures in new residential buildings

Small-scale Methodology AMS-III.AE.: Energy efficiency and renewable energy measures in new residential buildings CLEAN DEVELOPMENT MECHANISM CDM-EB101-A14 Small-scale Methodology AMS-III.AE.: Energy efficiency and renewable energy measures in new TABLE OF CONTENTS Page 1. INTRODUCTION... 3 2. SCOPE, APPLICABILITY,

More information

MEASUREMENT AND VERIFICATION GUIDELINES FOR RETROFIT AND NEW CONSTRUCTION PROJECTS

MEASUREMENT AND VERIFICATION GUIDELINES FOR RETROFIT AND NEW CONSTRUCTION PROJECTS EL PASO ELECTRIC COMPANY S LARGE COMMERCIAL AND INDUSTRIAL STANDARD OFFER PROGRAM MEASUREMENT AND VERIFICATION GUIDELINES FOR RETROFIT AND NEW CONSTRUCTION PROJECTS This document includes detailed information

More information

TARGETED TERTIARY PROTOCOL

TARGETED TERTIARY PROTOCOL TARGETED TERTIARY PROTOCOL VERSION 2.0 FEBRUARY 2018 TABLE OF CONTENTS THE INVESTOR CONFIDENCE PROJECT... 3 1.0 BASELINING... 5 2.0 SAVINGS CALCULATIONS... 9 3.0 DESIGN, CONSTRUCTION AND VERIFICATION...

More information

Practical Experiences in Applying Savings M&V

Practical Experiences in Applying Savings M&V Practical Experiences in Applying Savings M&V By Pierre Baillargeon P.Eng. Vice President, Econoler International, Canada Certified Measuvement & Verification professional (CMVP) September 25, 2006 Program

More information

Measurement & Verification The Principles

Measurement & Verification The Principles Measurement & Verification The Principles Des Murphy eevs / Kovara Typical Energy Conservation Measure: 4 year simple payback Will benefit owner for 10 years = Internal Rate of Return (IRR) of 20% So why

More information

Evidence based calibration of a building energy simulation model: Application to an office building in Belgium

Evidence based calibration of a building energy simulation model: Application to an office building in Belgium Evidence based calibration of a building energy simulation model: Application to an office building in Belgium Stéphane Bertagnolio Thermodynamics Laboratory Faculty of Applied Sciences University of Liège

More information

Incentives. After work is complete:

Incentives. After work is complete: SAVE your WAY Create your own Energy Demand Savings with OUC s Commercial & Industrial Custom Incentive Program Overview OUC is committed to helping your business become more energy efficient. We understand

More information

LIST OF TABLES LIST OF FIGURES ACKNOWLEDGEMENTS ABSTRACT INTRODUCTION LITERATURE REVIEW STEEPLE

LIST OF TABLES LIST OF FIGURES ACKNOWLEDGEMENTS ABSTRACT INTRODUCTION LITERATURE REVIEW STEEPLE 0 TABLE OF CONTENT LIST OF TABLES... 2 LIST OF FIGURES... 3 ACKNOWLEDGEMENTS... 4 ABSTRACT... 5 INTRODUCTION... 6 LITERATURE REVIEW... 7 STEEPLE Analysis... 7 Background... 9 METHODOLOGY... 12 ANALYSIS...

More information

Leveraging Smart Meter Data & Expanding Services BY ELLEN FRANCONI, PH.D., BEMP, MEMBER ASHRAE; DAVID JUMP, PH.D., P.E.

Leveraging Smart Meter Data & Expanding Services BY ELLEN FRANCONI, PH.D., BEMP, MEMBER ASHRAE; DAVID JUMP, PH.D., P.E. ASHRAE www.ashrae.org. Used with permission from ASHRAE Journal. This article may not be copied nor distributed in either paper or digital form without ASHRAE s permission. For more information about ASHRAE,

More information

Measurement and Verification, Commissioning Applications

Measurement and Verification, Commissioning Applications Measurement and Verification, Commissioning Applications Advisory Group Donald J. Frey, P.E. April 23, 2003 Potential Applications of M&V Methods Calculate Cx benefits. New Construction Design phase Construction

More information

Energy Modeling Applications for Existing Buildings

Energy Modeling Applications for Existing Buildings Energy Modeling Applications for Existing Buildings Presented by: Clark Denson PE, CEM, BEMP, LEED AP BD+C 4/27/12 Learning Objectives 1. List available methods and tools for energy modeling 2. Explain

More information

ENERGY PERFORMANCE PROTOCOL

ENERGY PERFORMANCE PROTOCOL ENERGY PERFORMANCE PROTOCOL PROJECT DEVELOPMENT SPECIFICATION Version 1.0 March 2016 Page 1 Table of Contents Contents 1.0 INVESTOR CONFIDENCE PROJECT... 5 1.1 ENERGY EFFICIENCY PERFORMANCE PROJECT DEVELOPMENT

More information

Strategies for Persistence: Measurement and Verification. Ryan Hughes PE, CEM, LEED AP Eaton Energy Solutions

Strategies for Persistence: Measurement and Verification. Ryan Hughes PE, CEM, LEED AP Eaton Energy Solutions Strategies for Persistence: Measurement and Verification Ryan Hughes PE, CEM, LEED AP Eaton Energy Solutions AIA Quality Assurance The Building Commissioning Association is a Registered Provider with The

More information

Building Control Strategies That Work to Improve Your Energy Bottom Line

Building Control Strategies That Work to Improve Your Energy Bottom Line Building Control Strategies That Work to Improve Your Energy Bottom Line William D. (Skip) Milton MBA, CEM, CEA Assistant Director of Facilities Operations Texas Children s Hospital Objective: Learn how

More information

A Case Study in Energy Modeling of an Energy Efficient Building with Gas Driven Absorption Heat Pump System in equest

A Case Study in Energy Modeling of an Energy Efficient Building with Gas Driven Absorption Heat Pump System in equest A Case Study in Energy Modeling of an Energy Efficient Building with Gas Driven Absorption Heat Pump System in equest Altamash A. Baig Alan S. Fung Mechanical and Industrial Engineering, Ryerson University

More information

Electric Standard Offer Program

Electric Standard Offer Program Electric Standard Offer Program Procedure No. 360-17 Limits Used To Verify Energy Savings 1. Purpose: To document the rational and intent for the use of limits in the energy savings calculations utilized

More information

Energy Consumption Analysis and Energy Conservation Evaluation of a. Commercial Building in Shanghai

Energy Consumption Analysis and Energy Conservation Evaluation of a. Commercial Building in Shanghai Energy Consumption Analysis and Energy Conservation Evaluation of a Commercial Building in Shanghai Chen Chen Yiqun Pan ZhizhongHuang Gang Wu Master Ph.D. Assistant Engineer Associate Professor Senior

More information

Success with MEASUREMENT & VERIFICATION

Success with MEASUREMENT & VERIFICATION 2016 Success with MEASUREMENT & VERIFICATION Prepared for the North Carolina Department of Environmental Quality. Project funded by the U.S. Department of Energy, Office of Energy Efficiency and Renewable

More information

AIT Austrian Institute of Technology

AIT Austrian Institute of Technology AIT Austrian Institute of Technology Review of methods for evaluation of building energy enhancements Florian Judex Scientist SBT Introduction Improved energy efficiency is the goal of many (funded) projects

More information

PROVING THE SAVINGS: MEASUREMENT & VERIFICATION

PROVING THE SAVINGS: MEASUREMENT & VERIFICATION METERING BILLING CRM/CIS CONFERENCE 2005 Le Meridien at Rialto, Melbourne Australia 16 March 2005 PROVING THE SAVINGS: MEASUREMENT & VERIFICATION Presented by Fred Nicolosi Copyright 2004 Energy Decisions

More information

How Much is Enough? Lessons Learned on Performance Periods for Monthly Whole Building Regression Modeling

How Much is Enough? Lessons Learned on Performance Periods for Monthly Whole Building Regression Modeling How Much is Enough? Lessons Learned on Performance Periods for Monthly Whole Building Regression Modeling Eva Urbatsch, Aerotek Erik Boyer, Bonneville Power Administration ABSTRACT Whole Building data

More information

Energy Efficiency Impact Study

Energy Efficiency Impact Study Energy Efficiency Impact Study for the Preferred Resources Pilot February, 2016 For further information, contact PreferredResources@sce.com 2 1. Executive Summary Southern California Edison (SCE) is interested

More information

4/30/2018. Connecticut Energy Efficiency Board C1630: Largest Savers Evaluation April 25, Overview

4/30/2018. Connecticut Energy Efficiency Board C1630: Largest Savers Evaluation April 25, Overview Agenda Overview Connecticut Energy Efficiency Board C163: Largest Savers Evaluation April 25, 218 Methodology Results Jason Hinsey and Dan Thompson 2 Overview: Study Objectives 1. Evaluate the energy and

More information

GLOSSARY OF TERMS January 2017

GLOSSARY OF TERMS January 2017 GLOSSARY OF TERMS January 2017 ENERGY EFFICIENCY GLOSSARY Advanced Meter Any new or appropriately retrofitted meter that functions as part of an advanced metering system and that has the features specified

More information

Assessing the Operational Energy Profiles of UK educational buildings: findings from detailed surveys and modelling compared to measured consumption

Assessing the Operational Energy Profiles of UK educational buildings: findings from detailed surveys and modelling compared to measured consumption 2nd PALENC Conference and 28th AIVC Conference on Building Low Energy Cooling and 531 Assessing the Operational Energy Profiles of UK educational buildings: findings from detailed surveys and modelling

More information

Supplemental Data for California Smart Thermostat Work Paper

Supplemental Data for California Smart Thermostat Work Paper Supplemental Data for California Smart Thermostat Work Paper Large scale analysis of the efficiency of Nest customer thermostat set point schedules with projected heating and cooling savings compared to

More information

Evaluation of whole-building energy baseline models for Measurement & Verification of commercial buildings

Evaluation of whole-building energy baseline models for Measurement & Verification of commercial buildings Evaluation of whole-building energy baseline models for Measurement & Verification of commercial buildings WP Robbertse 21076774 Dissertation submitted in partial fulfilment of the requirements for the

More information

AN INTRODUCTION TO WEATHER NORMALIZATION OF UTILITY BILLS FOR ALTERNATIVE ENERGY CONTRACTORS. John Avina, Director Abraxas Energy Consulting

AN INTRODUCTION TO WEATHER NORMALIZATION OF UTILITY BILLS FOR ALTERNATIVE ENERGY CONTRACTORS. John Avina, Director Abraxas Energy Consulting AN INTRODUCTION TO WEATHER NORMALIZATION OF UTILITY BILLS FOR ALTERNATIVE ENERGY CONTRACTORS John Avina, Director Abraxas Energy Consulting UTILITY BILL TRACKING: THE REPORT CARD FOR ALTERNATIVE ENERGY

More information

D DAVID PUBLISHING. Optimizing Thermal Energy Storage Systems in the Hospitality Industry. 1. Introduction

D DAVID PUBLISHING. Optimizing Thermal Energy Storage Systems in the Hospitality Industry. 1. Introduction Journal of Energy and Power Engineering 8 (2014) 1991-2000 D DAVID PUBLISHING Optimizing Thermal Energy Storage Systems in the Hospitality Industry Patrick Wilkinson, Jesse Oshiro, Dean Perry and Helen

More information

ENERGY EFFICIENT RETROFIT OF A HIGH-RISE MULTIFAMILY BUILDING

ENERGY EFFICIENT RETROFIT OF A HIGH-RISE MULTIFAMILY BUILDING ENERGY EFFICIENT RETROFIT OF A HIGH-RISE MULTIFAMILY BUILDING Brittany Hanam 1, Lorne Ricketts 2, Andrew Pape-Salmon 3 ABSTRACT The National Institute of Building Sciences estimates that over 70% of the

More information

PARK PLACE CASE STUDY VANCOUVER. Heat reclaim system expected to reduce steam consumption 80%, GHG emissions 68%

PARK PLACE CASE STUDY VANCOUVER. Heat reclaim system expected to reduce steam consumption 80%, GHG emissions 68% Heat reclaim system expected to reduce steam consumption 80%, GHG emissions 68% Address 666 Burrard St, Vancouver Management QuadReal Property Group Type of Building Office Year of Construction 1984 Number

More information

M&V Guidelines for Colorado PC projects. You cannot manage what you do not measure

M&V Guidelines for Colorado PC projects. You cannot manage what you do not measure M&V Guidelines for Colorado PC projects You cannot manage what you do not measure Rebuild Colorado Focus on performance contracting in state and local governments Rebuild Colorado Team Governor s Office

More information

M&V 2.0: A User s Guide

M&V 2.0: A User s Guide M&V 2.0: A User s Guide West Coast Energy Management Congress June 8, 2017 David Jump, Ph.D., P.E. kw Engineering djump@kw-engineering.com 1 Agenda What is M&V 2.0? Process Steps & Tools Non-Routine Events

More information

Building Upgrade Finance No worse off Methodology for Estimating Tenant Cost Savings 1

Building Upgrade Finance No worse off Methodology for Estimating Tenant Cost Savings 1 Building Upgrade Finance No worse off Methodology for Estimating Tenant Cost Savings 1 The approved methodology for the purpose of Schedule 1B of the Local Government Act 1999 1. PURPOSE This document

More information

Whole Building Energy Performance Evaluation through. Similar Control Strategies

Whole Building Energy Performance Evaluation through. Similar Control Strategies Whole Building Energy Performance Evaluation through Similar Control Strategies S.H. Cheon 1, Y.H. Kwak 1, C.Y. Jang 2, and J.H. Huh 1* 1 Department of Architectural Engineering, University of Seoul, Seoul

More information

STANDARD TERTIARY PROTOCOL

STANDARD TERTIARY PROTOCOL VERSION EU 1.0 MARCH 2016 This project has received funding from the European Union s Horizon 2020 research and innovation programme under grant agreement No 649836. The sole responsibility for the content

More information

A HYBRID MONITORING-MODELING PROCEDURE FOR ANALYZING THE PERFORMANCE OF LARGE CENTRAL CHILLING PLANTS

A HYBRID MONITORING-MODELING PROCEDURE FOR ANALYZING THE PERFORMANCE OF LARGE CENTRAL CHILLING PLANTS A HYBRID MONITORING-MODELING PROCEDURE FOR ANALYZING THE PERFORMANCE OF LARGE CENTRAL CHILLING PLANTS Ricardo Troncoso, P.E. Senior Engineer ACR Engineering, Incorporated 97 South Congress Avenue Austin,

More information

Project Information. Measure Description

Project Information. Measure Description Project Information Project ID#: CE07M016 Measure: Multiple Electric : 452,593 kwh, 8.84 kw, 39.26 kw Facility Type School Technology: Multiple Measure Description CH-1 - Chiller Plant Optimization and

More information

LOADS, CUSTOMERS AND REVENUE

LOADS, CUSTOMERS AND REVENUE Page of LOADS, CUSTOMERS AND REVENUE The purpose of this evidence is to present the Company s load, customer and distribution revenue forecast for the test years. The detailed test year forecasts are shown

More information

Measurement and Verification: Monitoring Lighting Systems for Optimal Performance

Measurement and Verification: Monitoring Lighting Systems for Optimal Performance Measurement and Verification: Monitoring Lighting Systems for Optimal Performance February 2011/1200DB1101 by Scott Jordan, Product Marketing Manager, LifeSpace Division of Schneider Electric Make the

More information

ENERGY STAR Portfolio Manager. Technical Reference. ENERGY STAR Score for Supermarkets and Food Stores in Canada OVERVIEW

ENERGY STAR Portfolio Manager. Technical Reference. ENERGY STAR Score for Supermarkets and Food Stores in Canada OVERVIEW OVERVIEW ENERGY STAR Score for Supermarkets and Food Stores in Canada The ENERGY STAR Score for Supermarket and Food Stores in Canada applies to supermarkets, grocery stores, food sales and convenience

More information

Pay for Performance Case Study 3 Years of Performance

Pay for Performance Case Study 3 Years of Performance Pay for Performance Case Study 3 Years of Performance Chris Smith, PE, CEM Energy 350 Kathleen Belkhayat & Oliver Kesting Energy Trust of Oregon Introduction A Pay for Performance (PfP) program structure

More information

Improving Energy Retrofit Decisions by Including Uncertainty in the Energy Modelling Process

Improving Energy Retrofit Decisions by Including Uncertainty in the Energy Modelling Process Improving Energy Retrofit Decisions by Including Uncertainty in the Energy Modelling Process Alireza Bozorgi 1, James R. Jones 2 1 ICF International, Atlanta, GA 2 Virginia Tech, Blacksburg, VA ABSTRACT:

More information

Commercial Retro-Commissioning Program Manual for 2015 SECTION 1

Commercial Retro-Commissioning Program Manual for 2015 SECTION 1 Commercial Retro-Commissioning Program Manual for 2015 SECTION 1 Introduction The Commercial Retro-Commissioning Program (RCx) is designed to achieve demand and energy savings in commercial facilities.

More information

TARGETED TERTIARY PROTOCOL

TARGETED TERTIARY PROTOCOL VERSION EU 1.0 MARCH 2016 This project has received funding from the European Union s Horizon 2020 research and innovation programme under grant agreement No 649836. The sole responsibility for the content

More information

STREET LIGHTING PROTOCOL

STREET LIGHTING PROTOCOL STREET LIGHTING PROTOCOL VERSION 1.2 JULY 2018 This project has received funding from the European Union s Horizon 2020 research and innovation programme under grant agreement No 754056. The sole responsibility

More information

Allied Irish Bank. Global Energy Management System Implementation: Case Study. Republic of Ireland

Allied Irish Bank. Global Energy Management System Implementation: Case Study. Republic of Ireland Global Energy Management System Implementation: Case Study Allied Irish Bank Total demonstrated energy savings of $1.5m since 2014, and 21% reduction in energy consumption. We want AIB to become a leader

More information

Effective Energy Modeling WGBA Leadership Conference October 19, 2005

Effective Energy Modeling WGBA Leadership Conference October 19, 2005 Effective Energy Modeling WGBA Leadership Conference October 19, 2005 Steven Carlson, P.E. CDH Energy Corp. Evansville, WI www.cdhenergy.com Presentation Overview What Why How Illustrated by experiences

More information

Performance of Ductless Heat Pumps in the Northeast

Performance of Ductless Heat Pumps in the Northeast Performance of Ductless Heat Pumps in the Northeast Bruce Harley, CSG BE2014 / High Performance Mechanicals March 6, 2014 Amended 6/3/2014 Titles/details in RED indicate significant changes NESEA is a

More information

National Grid USA Service Company. Impact Evaluation Of 2006 Design2000plus Custom Comprehensive Projects. Final Report

National Grid USA Service Company. Impact Evaluation Of 2006 Design2000plus Custom Comprehensive Projects. Final Report National Grid USA Service Company Impact Evaluation Of 2006 Design2000plus Custom Comprehensive Projects Final Report July 11, 2010 Submitted to: National Grid USA Service Corporation Waltham, MA Submitted

More information

HVAC INTEGRATED CONTROL FOR ENERGY SAVING AND COMFORT ENHANCEMENT vahid Vakiloroaya

HVAC INTEGRATED CONTROL FOR ENERGY SAVING AND COMFORT ENHANCEMENT vahid Vakiloroaya HVAC INTEGRATED CONTROL FOR ENERGY SAVING AND COMFORT ENHANCEMENT vahid Vakiloroaya (vahid.vakiloroaya@engineer.com) ABSTRACT: The overall attainable reduction in energy consumption and enhancement of

More information

SOLAR ASSISTED HVAC HVAC

SOLAR ASSISTED HVAC HVAC HVAC Team Members Shaun Worthmann, Real Time Energy (Pty) Ltd; Professor Ognyan Dintchev, Tshwane University of Technology; Professor Ian Joseph Lazarus, Durban University of Technology ABSTRACT Toyota

More information

Measurement and verification of load shifting interventions for a fridge plant system in South Africa

Measurement and verification of load shifting interventions for a fridge plant system in South Africa Measurement and verification of load shifting interventions for a fridge plant system in South Africa Rupert Gouws School of Electrical, Electronic and Computer Engineering, North-West University, Potchefstroom

More information

EVALUATING THE ENERGY SAVINGS OF HIGH PERFORMANCE BUILDING ENCLOSRE RETROFITS Brittany Hanam, MASc, P.Eng. Graham Finch, MASc, P.Eng.

EVALUATING THE ENERGY SAVINGS OF HIGH PERFORMANCE BUILDING ENCLOSRE RETROFITS Brittany Hanam, MASc, P.Eng. Graham Finch, MASc, P.Eng. EVALUATING THE ENERGY SAVINGS OF HIGH PERFORMANCE BUILDING ENCLOSRE RETROFITS Brittany Hanam, MASc, P.Eng. Graham Finch, MASc, P.Eng. ABSTRACT Building enclosure retrofits for multiunit residential buildings

More information

FOUR YEARS OF ON-GOING COMMISSIONIONG IN CTEC-VARENNES BUILDING WITH A BEMS ASSISTED CX TOOL

FOUR YEARS OF ON-GOING COMMISSIONIONG IN CTEC-VARENNES BUILDING WITH A BEMS ASSISTED CX TOOL FOUR YEARS OF ON-GOING COMMISSIONIONG IN CTEC-VARENNES BUILDING WITH A BEMS ASSISTED CX TOOL Daniel Choinière, eng. CANMET-Energy Technology Centre (CETC-V) Natural Resources Canada 1615 Lionel-Boulet

More information

IMPACT OF NIGHTTIME SJXJT DOWN ON THE PREDICTION ACCURACY OF MONTHLY REGRESSION MODELS FOR ENERGY CONSUMPTION IN COMMERCIAL BUILDINGS

IMPACT OF NIGHTTIME SJXJT DOWN ON THE PREDICTION ACCURACY OF MONTHLY REGRESSION MODELS FOR ENERGY CONSUMPTION IN COMMERCIAL BUILDINGS IMPACT OF NIGHTTIME SJXJT DOWN ON THE PREDICTION ACCURACY OF MONTHLY REGRESSION MODELS FOR ENERGY CONSUMPTION IN COMMERCIAL BUILDINGS Jinrong Wang and David E. Claridge Energy Systems Laboratory Mechanical

More information

Required Treatment of District Thermal Energy in LEED-NC version 2.2 and LEED for Schools

Required Treatment of District Thermal Energy in LEED-NC version 2.2 and LEED for Schools 1 Required Treatment of District Thermal Energy in LEED-NC version 2.2 and LEED for Schools Version 1.0 May 28, 2008 Administrative All LEED-NC v2.2 or LEED for Schools projects that register with USGBC

More information

Richmond Building Energy Challenge. Benchmarking

Richmond Building Energy Challenge. Benchmarking Richmond Building Energy Challenge Benchmarking Agenda Why Energy Management? Why Benchmark Energy Use? Value of Portfolio Manager Features of Portfolio Manager Tool Using Portfolio Manager How the Richmond

More information

Recommissioning Energy Savings Persistence

Recommissioning Energy Savings Persistence Recommissioning Energy Savings Persistence Martin Selch and James Bradford, PE, PhD Nexant, Inc. Synopsis Utilities, administrators, or turnkey providers in many areas around the country offer recommissioning

More information

Improving the efficiency, occupant comfort, and financial well-being of campus buildings

Improving the efficiency, occupant comfort, and financial well-being of campus buildings GHAUSI HALL ENERGY PROJECT REPORT Improving the efficiency, occupant comfort, and financial well-being of campus buildings ACE TEAM, ENERGY CONSERVATION OFFICE UC DAVIS FACILITIES MANAGEMENT Executive

More information

IMPROVING OPERATIONAL STRATEGIES OF AN INSTITUTIONAL BUILDING IN KUWAIT

IMPROVING OPERATIONAL STRATEGIES OF AN INSTITUTIONAL BUILDING IN KUWAIT IMPROVING OPERATIONAL STRATEGIES OF AN INSTITUTIONAL BUILDING IN KUWAIT Fatouh Al-Ragom, CEM Research Associate Kuwait Institute for Scientific Research Kuwait ABSTRACT The Building and Energy Technologies

More information

eu.bac System Certification Scheme Certifying Energy Efficiency of Building Automation and Control Systems, at first delivery and during the lifetime

eu.bac System Certification Scheme Certifying Energy Efficiency of Building Automation and Control Systems, at first delivery and during the lifetime PART 5 Classification System 2013-07-12 Certification Scheme Certifying Energy Efficiency of Building Automation and Control Systems, at first delivery and during the lifetime Part 5: Classification System

More information

PJM Manual 18B: Energy Efficiency Measurement & Verification Revision: 03 Effective Date: November 17, Prepared by PJM Forward Market Operations

PJM Manual 18B: Energy Efficiency Measurement & Verification Revision: 03 Effective Date: November 17, Prepared by PJM Forward Market Operations PJM Manual 18B: Energy Efficiency Measurement & Verification Revision: 03 Effective Date: November 17, 2016 Prepared by PJM Forward Market Operations PJM 2016 Table of Contents Table of Contents Approval...5

More information

Technical Reference. Portfolio Manager ENERGY STAR. Parking and the ENERGY STAR Score in the United States and Canada OVERVIEW

Technical Reference. Portfolio Manager ENERGY STAR. Parking and the ENERGY STAR Score in the United States and Canada OVERVIEW OVERVIEW and the ENERGY STAR Score in the United States and Canada The ENERGY STAR score provides a fair assessment of the energy performance of a property relative to its peers, taking into account the

More information

The Ex Ante Calculations match the claimed savings in the project tracking system.

The Ex Ante Calculations match the claimed savings in the project tracking system. Project Information Project ID#: Measure: Ex Ante : Facility Type: End Use: CE06M003 Compressed Air System 354,654 kwh, 56.4 kw Manufacturing Compressed Air Measure Description This project consisted of

More information

Energy Efficiency Measurement and verification in South Africa for bigee. Authors Xianming Ye CNES University of Pretoria Approved by SANEDI

Energy Efficiency Measurement and verification in South Africa for bigee. Authors Xianming Ye CNES University of Pretoria Approved by SANEDI Energy Efficiency Measurement and verification in South Africa for bigee Authors Xianming Ye CNES University of Pretoria Approved by SANEDI 06/2017 bigee measurement and verification Table of contents

More information

Energy modeling in IDA ICE according to ASHRAE , app. G

Energy modeling in IDA ICE according to ASHRAE , app. G Energy modeling in IDA ICE according to ASHRAE 90.1-2007, app. G About this document This document is a user s guide for a relatively experienced IDA ICE operator for using the 90.1 add-in and for performing

More information

Energy Consumption Prediction Model of the Residential Sector. Abstract. 1. Introduction

Energy Consumption Prediction Model of the Residential Sector. Abstract. 1. Introduction Energy Consumption Prediction Model of the Residential Sector Patrícia Branquinho, Instituto Superior Técnico, Universidade de Lisboa Abstract Nowadays, the buildings sector is responsible for about 40%

More information

10 Energy consumption of buildings direct impacts of a warming climate and rebound effects

10 Energy consumption of buildings direct impacts of a warming climate and rebound effects 10 Energy consumption of buildings direct impacts of a warming climate and rebound effects energy for heating/cooling effect on total energy use and GDP Heating energy demand of Swiss households decreases

More information

SMART HVAC & LIGHTING SYSTEMS. Savings From Two Major C&I End Uses

SMART HVAC & LIGHTING SYSTEMS. Savings From Two Major C&I End Uses SMART HVAC & LIGHTING SYSTEMS Savings From Two Major C&I End Uses September 21, 2016 PRESENTATION OVERVIEW Why this focus? Significant savings potential Smart controls coupled with more efficient technologies

More information

Energy Management Measures Evaluation and Financing Energy Management

Energy Management Measures Evaluation and Financing Energy Management Energy Management Measures Evaluation and Financing Energy Management Carlos A. Santos Silva Outlook Energy Efficiency Measures Project Evaluation Definitions Evaluation metrics Example Financing Energy

More information

M&V Guidelines: Measurement and Verification for Federal Energy Projects. Version 3.0

M&V Guidelines: Measurement and Verification for Federal Energy Projects. Version 3.0 M&V Guidelines: Measurement and Verification for Federal Energy Projects Version 3.0 M&V Guidelines: Measurement and Verification for Federal Energy Projects Version 3.0 Prepared For: U.S. Department of

More information

A METHODOLOGY FOR REDUCING BUILDING ENERGY CONSUMPTION

A METHODOLOGY FOR REDUCING BUILDING ENERGY CONSUMPTION ME 164 Senior Capstone Design The Cooper Union Spring 2014 A METHODOLOGY FOR REDUCING BUILDING ENERGY CONSUMPTION Eric Leong Cooper Union New York, NY Advised by Prof. Melody Baglione Cooper Union New

More information

Coupling night ventilative and active cooling to reduce energy use in supermarkets with high refrigeration loads

Coupling night ventilative and active cooling to reduce energy use in supermarkets with high refrigeration loads Coupling night ventilative and active cooling to reduce energy use in supermarkets with high refrigeration loads ABSTRACT Zoi Mylona *1, Maria Kolokotroni 1 and Savvas Tassou 1 1 RCUK National Centre for

More information

Analysis of the Energy Savings Potential in K-5 Schools in Hot and Humid Climates. Jeff S. Haberl, Ph.D., P.E.

Analysis of the Energy Savings Potential in K-5 Schools in Hot and Humid Climates. Jeff S. Haberl, Ph.D., P.E. Analysis of the Energy Savings Potential in K-5 Schools in Hot and Humid Climates Piljae Im Graduate Student Jeff S. Haberl, Ph.D., P.E. Professor Energy Systems Laboratory Texas Engineering Experiment

More information

Effects of the use of DIN on the energetic assessment of residential buildings reflection on the calculation

Effects of the use of DIN on the energetic assessment of residential buildings reflection on the calculation Abstract Effects of the use of DIN 18599 on the energetic assessment of residential buildings reflection on the calculation approaches The research report was financially supported by the research initiative

More information

Sustainable Design for Hospitals in Taiwan

Sustainable Design for Hospitals in Taiwan Scientific Cooperations Journal of Civil Engineering and Architecture, Vol. 1, Issue. 1, August-2015 1 Sustainable Design for Hospitals in Taiwan Po-Han Chen Department of Civil Engineering National Taiwan

More information

Final Report for National Grid USA Service Company. Evaluation of 2003 Custom HVAC Installations Part II. September 27, 2005.

Final Report for National Grid USA Service Company. Evaluation of 2003 Custom HVAC Installations Part II. September 27, 2005. Final Report for National Grid USA Service Company Evaluation of 2003 Custom HVAC Installations Part II September 27, 2005 Submitted by Select Energy Services, Inc. is the energy services subsidiary of

More information

ASHRAE s LowDown Showdown

ASHRAE s LowDown Showdown ASHRAE s LowDown Showdown Presented to the Building Energy Simulation Forum 14 February 2018 James Cullin, PhD, PE Overview Project Approach Existing Building Modeling/Calibration Proposed Design Proposed

More information

Investor Confidence Project

Investor Confidence Project Investor Confidence Project Project Developer and Quality Assurance Assessor Training: Industry 17th July 2018 Presenters: Luís Castanheira, ICP Europe Technical Director Bethan Phillips, ICP Europe Technical

More information

COMPLEX INDUSTRY AND ENERGY SUPPLY PROTOCOL

COMPLEX INDUSTRY AND ENERGY SUPPLY PROTOCOL COMPLEX INDUSTRY AND ENERGY SUPPLY PROTOCOL VERSION 1.3 SEPTEMBER 2018 This project has received funding from the European Union s Horizon 2020 research and innovation programme under grant agreement No

More information

Solar cooling design: a case study

Solar cooling design: a case study Eco-Architecture IV 399 Solar cooling design: a case study S. Grignaffini & M. Romagna Department of Astronautic, Electric and Energetic Engineering, Sapienza, University of Rome, Italy Abstract Throughout

More information

Commissioning In Energy Savings Performance Contracts

Commissioning In Energy Savings Performance Contracts Commissioning In Energy Savings Performance Contracts Karl Stum, P.E., Portland Energy Conservation Inc. (PECI) ABSTRACT Energy savings performance contracts (PCs) using the international measurement and

More information

M&V Applications and Approaches Balancing Project Demands to Deliver an Accurate, Cost Effective, and Verifiable M&V Outcome

M&V Applications and Approaches Balancing Project Demands to Deliver an Accurate, Cost Effective, and Verifiable M&V Outcome M&V Applications and Approaches Balancing Project Demands to Deliver an Accurate, Cost Effective, and Verifiable M&V Outcome Doug Chamberlin, P.E., LEED AP; Director of Northwest Region Mark Goldberg;

More information

Energy Performance of Buildings Directive: Achieving both high indoor air quality and low energy consumption in European buildings

Energy Performance of Buildings Directive: Achieving both high indoor air quality and low energy consumption in European buildings Energy Performance of Buildings Directive: Achieving both high indoor air quality and low energy consumption in European buildings EVIA calls upon decision-makers to strengthen provisions ensuring proper

More information

1. How the research adds to the understanding of the area investigated

1. How the research adds to the understanding of the area investigated Final Scientific/Technical Report Project Title: CID #: Recipient: Eagan Civic Arena DE-EE0002807 Cherryl Mesko City of Eagan Minnesota 3830 Pilot Knob Road Eagan, MN 55122 cmesko@cityofeagan.com 651-675-5505

More information

Truing-Up to Billing Data

Truing-Up to Billing Data Truing-Up to Billing Data The Imperative for Accurate Software Estimations Dave Beaulieu- CSG Ethan MacCormick- PSD Presenters Ethan MacCormick Dave Beaulieu Description: This session will provide concrete

More information

Simplified M&V + Quality Assurance Instruments for Energy, Water and CO2 Savings. Methodologies and Examples

Simplified M&V + Quality Assurance Instruments for Energy, Water and CO2 Savings. Methodologies and Examples Task 16 Competitive Energy Services www.ieadsm.org in cooperation with: IEA DSM Task 16 + Sattler Simplified M&V + Quality Assurance Instruments for Energy, Water and CO2 Savings. Methodologies and Examples

More information

PROCESS & SYSTEMS PROCESS & SYSTEMS

PROCESS & SYSTEMS PROCESS & SYSTEMS saveonenergy Baseline Methodology Guidelines Baseline Methodology Guidelines Purpose This document is intended to provide Program Participants and engineering consultants with guidelines around acceptable

More information

Dynamic simulation of buildings: Problems and solutions Università degli Studi di Trento

Dynamic simulation of buildings: Problems and solutions Università degli Studi di Trento Dynamic simulation of buildings: Problems and solutions Università degli Studi di Trento Paolo BAGGIO The basic problem To design (and operate) energy efficient buildings, accurate modeling tools are needed.

More information

Meeting the Variable Needs of Energy- Efficient Mechanical Ventilation When and Where You Need It

Meeting the Variable Needs of Energy- Efficient Mechanical Ventilation When and Where You Need It Meeting the Variable Needs of Energy- Efficient Mechanical Ventilation When and Where You Need It Charles Withers Jr. 1 Introduction Effectively providing mechanical ventilation in commercial buildings

More information

ENERGY EFFICIENCY GUIDEBOOK FOR EDUCATIONAL INSTITUTIONS

ENERGY EFFICIENCY GUIDEBOOK FOR EDUCATIONAL INSTITUTIONS ENERGY EFFICIENCY GUIDEBOOK FOR EDUCATIONAL INSTITUTIONS SUPPORTING PARTNERS ENERGY EFFICIENCY GUIDEBOOK FOR EDUCATIONAL INSTITUTIONS ENERGY EFFICIENCY GUIDEBOOK FOR EDUCATIONAL INSTITUTIONS OUTLINE OF

More information