1 Final Report on the determination of the odorous substance concentration in the screening building Dinslaken sewage treatment plant with and without the use of a test facility for the reduction of odour Client: Lippeverband Kronprinzenstrasse Essen Order number: ANECO-order number: P Advisors: Dipl.-Chem. M. Robert Dipl.- lng. T. Diesler No. of pages: 14 pages + 6 pages attachment Date: 31 August 2009
2 C O N T E N T S 1. Summary 2. General objectives and terms of reference 3. Conduction of the olfactometric determination 4. Results 5. Discussion of the results 6. Literature Attachment (6 pages)
3 1. Summary The Lippeverband operates a sewage treatment plant at Voerder Strasse in Dinslaken and is currently taking measures in various parts of the plant to reduce odours. A test facility to reduce odour has been operated in the screening building by the Finnish company Desinfinator as a trial. In order to prove whether a measurable reduction in odour can be achieved with the procedure, odour measurements were taken in the screening building on two separate dates (with and without the operation of the test facility). In addition, ozone measurements were conducted during the operation of the test facility. The Lippeverband commissioned the ANECO Institut für Umweltschutz GmbH & Co., appointed by a decree by the Ministry for Environmental Protection and Nature Conservation, Agriculture and Consumer Affairs of North-Rhine Westphalia [1] pursuant to 26, 28 BImSchG [2], with the conduction of the odour measurements in the screening building with and without the operation of the test facility. The measuring point was set up in consultation with the Lippeverband at a position in the screening building that was as representative as possible and in the same place for each of the two sampling dates. All operational parameters were maintained as constant as possible on both measurement dates. Three samples each were taken on two measurement dates, on without and on with the operation of the test facility, with a duration of 30 minutes in each case. A total of 6 samples were taken and analysed. In addition, the ozone concentration in the screening building was determined on the second date with the test facility. In the operation of the screening plant without test facility, odour concentrations of OUE/m³ were identified. Upon the deployment of the test facility, the odorous substance concentration fell clearly to 4000 OUE/m³. A reduction in odorous substance concentration of 9300 OUE/m³ was observed. According to a statement by the Lippeverband, the operational conditions were comparable on both measurement dates. The ozone concentration during operation of the test facility was < 3.0 µg/m³. As there is currently no new workplace limitation for ozone in interior spaces, the TRGS 900 workplace limitation value of 200 µg/m³, which is no longer valid for technical reasons, is taken as a reference.
4 2. General objectives and terms of reference The Lippeverband operates a sewage treatment plant at Voerder Strasse in Dinslaken and is currently taking measures in various parts of the plant to reduce odours. A test facility to reduce odour has been operated in the screening building by the Finnish company Desinfinator as a trial. In order to prove whether a measurable reduction in odour can be achieved with the procedure, odour measurements were taken in the screening building on two separate dates (with and without the operation of the test facility). The Lippeverband commissioned the ANECO Institut für Umweltschutz GmbH & Co., appointed by a decree by the Ministry for Environmental Protection and Nature Conservation, Agriculture and Consumer Affairs of North-Rhine Westphalia [1] pursuant to 26, 28 BImSchG [2], with the conduction of the odour measurements in the screening building with and without the operation of the test facility. The following picture shows the location of the screening building in the sewage treatment plant. PICTURE 1: Location of the screening building of the Dinslaken sewage treatment plant
5 The test facility of the company DESINFINATOR OY LTD to reduce odours is presented in the following picture. During the second sampling date on 25 August 2009 the devices were operational with sufficient lead time. PICTURE 2: Test facility of the company DESINFINATOR OY LTD
6 3. Conduction of the olfactometric determination 3.1 Samples The conduction of the measurements took place in accordance with the provisions of DIN EN Air quality Determination of odorous substance concentration with dynamic olfactometry [3]. Static sampling procedures were employed based on the source to be examined. In static sampling the sample is taken according to the lung principle in an odourless sample container. The sample bag is placed in an airtight container and air is removed from the container by means of a pump. The negative pressure in the container causes the bag to fill up. In addition, the air temperature and the relative moisture in the screening building are specified. In order to determine the ozone concentration in the screening building during operation of the test facilities, a discontinuous sampling was conducted with two Muenke wash bottles that were darkened and connected one behind the other. Here the air sample was taken by means of a potassium iodide solution. The extinction of the iodine solution is proportional to the ozone concentration of the air sample and was recorded spectroscopically at a wavelength of 350 nm. 3.2 Measuring point The measuring point was set up in consultation with the Lippeverband at a position in the screening building that was as representative as possible and in the same place for each of the two sampling dates. All operational parameters were maintained as constant as possible on both measurement dates. The schematic structure of the screening building and the sampling point is illustrated in the following picture.
7 PICTURE 3: Schematic representation of the screening building, the test facility (red) and the sampling point
8 The sampling point in the screening building is shown in the picture below. PICTURE 4: Sampling point in the screening building
9 3.3 Measuring height The odorous substance and ozone samples were taken at a height of around 1.75 m above the ground and at a distance of more than 1.5 m from the side walls or other obstacles. 3.4 Duration of the sampling and number of samples Three odorous substance samples each were taken on two measurement dates with a duration of 30 minutes each. A total of 6 samples were taken and analysed. In addition the ozone concentration in the test facility was determined on the measurement date with repeat determination and a sampling duration of 2 hours. 3.5 Transport and storage of the samples prior to measurement During transport and storage the samples were kept at 25 C and not exposed to direct sunlight in order to minimise photochemical reactions and diffusion.
10 3.6 Presentation of the odorous substances to the examiners The odorous substance concentration is determined by a panel of selected and verified persons, who are presented with this sample in different concentrations by means of dilution with neutral air. The purpose is to find the dilution factor at which in 50 % of cases an odour is perceived (Z 50 ). The presentation was carried out according to the yes/no model, i.e. the examiners are asked to evaluate the gas presented and to state whether an odour is perceived (yes/no). Three measurement rounds were conducted for each of the 6 sample bags, i.e. three measurement values were determined for each sample taken and the average was calculated. The measurement unit for odorous substance concentration is the European Odour Unit per cubic metre [OU E /m³]. The odorous substance concentration is measured by determining the dilution factor that is necessary to reach the perception threshold. The odorous substance concentration at the perception threshold is defines as 1 OU E /m³. The odorous substance concentration is then expressed as a multiple of the perception threshold. The field of measurement usually lies between 10 1 and 10 7 OU E /m³.
11 3.6.1 Olfactometer The data of the olfactometer used are summarised in the following list. Olfactometer Make: ECOMA GmbH, Kiel Type: TO7 Year of construction: 1997 Series number: EO.033 Dilution principle: gas jet pump Integrated predilution: pre-mix ratio adjustable with gas jet pump Dilution air: ambient air Preparation of the diluted air: particle filter, silica gel and activated carbon filter Control mechanism of the flow rates: variable area flow meters; optical control of the dilution setting Excess outlet for air samples: pre-mix expelled air by means of activated carbon filter Number of outlets for odour samples: 1 per test person position Number of test persons working at the device at the same time: 4 Design of the olfactometer outlet: unsealed stainless steel Volume flow of the odour sample: 1.2 m³/h per measuring point during the inhalation phase Largest variable dilution with / without predilution: 640 / Smallest variable dilution with / without predilution: 2.5 / 62.5 Standard deviation of the settings of the dilution stages: < 10 % Detection limit of the olfactometric measurement facility: 7 OU E /m³ Repeatability r: Accuracy σw: Date of the last calibration: factory calibration by the company Ecoma ( ) Humidifying unit for neutral air: no Humidifying unit for odour sample: no Response time: < 1 s Adjustment time: < 1.5 s
12 3.6.2 Panel of test persons In order to determine the odorous substance concentrations a panel of 4 test persons was selected. Prior to the olfactometric examinations the odour thresholds of the test persons are checked in accordance with the requirements of the Odour Emissions Guidelines (Geruchsimmissions-Richtlinie GIRL [4]) with the test gases n-butanol, and for internal quality control, with hydrogen sulphide. The features of the test gases used are summarised in the following list. Test gas n-butanol: Manufacturer: Date of production: Stability guarantee: Certified: Test gas cylinder no: Traced: Test gas H 2 S: Manufacturer: Date of production: Stability guarantee: Certified: Test gas cylinder no: 60 ppm in nitrogen Westfalen AG months yes / 5 % G NMI-Standard 4.08 mg/m³ in nitrogen Air Liquide months yes / 3 % 8101 H Verification of the certificate by: ANECO Laboratory
13 4. Results The values of the odour measurements are presented in the following tables and diagrams, with and without the operation of the test facility. Measurement Without operation of the test facility: Sample label Measurement time Start End Odorous substance concentration [OU E /m³] Temperature [ C] relative moisture [%] 1 Lip1-11:28 11: Lip2-12:00 12: Lip3-12:35 13: Average: Measurement With operation of the test facility: Sample label Measurement time Start End Odorous substance concentration [OU E /m³] Temperature [ C] relative moisture [%] 1 Lip1-12:05 12: Lip2-12:32 13: Lip3-13:05 13: Average:
14 The values of the ozone concentration (repeat determination) in the screening building are presented in the following table. Measurement Sample label Measurement time Start End Ozone concentration [ug/m 3 ] Temperature [ C] 1 LipAB :05 14:05 < LipCD :05 14:05 <
15 5. Discussion of the results During operation of the screening plant without test facilities, odorous substance concentrations of OU E /m³ were found. The deployment of the test facility greatly reduced the odorous substance concentration to the degree of 4000 OU E /m³. According to Lippeverband the operational conditions on both measurement dates were comparable. The ozone concentration during operation of the test facility was < 3.0 µg/m³. As there is currently no new workplace limitation for ozone in interior spaces, the TRGS 900 workplace limitation value of 200 µg/m³, which is no longer valid for technical reasons, is taken as a reference.
16 6. Literature [1] Bekanntgabe des Ministeriums für Umwelt und Naturschutz, Landwirtschaft und Verbraucherschutz NRW vom ; Az.: V [2] Bundesimmissionsschutzgesetz Gesetz zum Schutz vor schädlichen Umwelteinwirkungen durch Luftverunreinigungen, Geräusche, Erschütterungen und ähnliche Vorgänge (Bundesimmissionsschutzgesetz - BlmSchG) vom 09. Oktober 1996, zuletzt geändert am (BGBI. I, S. 2470) [3] DIN EN Luftbeschaffenheit - Bestimmung der Geruchsstoffkonzentration mit dynamischer Olfaktometrie Stand: April 2006 [4] Feststellung und Beurteilung von Geruchsimmissionen (Geruchsimmissions-Richtlinie GIRL), mit Begründung und Auslegungshinweisen in der Fassung vom 29. Februar A N E C O Institut für Umweltschutz GmbH & Co. Monchengladbach, 31 August 2009 /TD The specialist responsible: The advisor: (Dipl.-lng. Torsten Diesler)
17 A T T A C H M E N T : Measurement and calculated values
18 NOTE: This is an example table with the translations. Original tables are in German. Location of the measurement: ANECO GmbH & Co. <> Wehnerstrasse 1-7 <> Mönchengladbach Olfactometry (measurement data reading) analogue to EN13725 Attachment F page 58 Sample label Order number Company: Lippeverband Lip P Lab staff : Borcherding Field staff Type of odour Serial no. Time sample Time Lab Diesler Sewage plant 8260 end 11:58 16:41 Description of the strongly putrid odour Predilution >= 1: 1 Time sample end to lab 4:43 Breathing [ms]: 2200 Break betw. samples [s]: 60 Rinse duration [s]: 5 % zero samples: 51 Temp. measuring room 22 Temperature drift[ C]: < 3 [ C] : Okay Precision from Accuracy from Odour neutrality of TO7: yes= X no = Sampling Round 1 Round 2 Round 3 Entries from T07 HeP ReS GiF SaS Round 1 Test person All values within tolerance - - Z IET First reading Second reading Z IET 8Z Z IET 8Z max 5 max 5 HeP ReS 8000 GiF SaS Round 2 Z IET Z IET 8Z Z IET max 5 8Z max 5 HeP ReS 4000 GiF 8000 SaS Round 3 Z IET Z IET 8Z Z IET max 5 8Z max 5 HeP 8000 ReS 8000 GiF 2000 SaS GE/m 3 8 Z IET (Z 50) Value without any predilution
19
20
21
22
23
24
ESTIMATION OF ODOUR EMISSIONS FROM FIELD INSPECTIONS (ESOFIN) AND A SCREENING MODEL FOR ODOUR DISPERSION (SMOD)
ESTIMATION OF ODOUR EMISSIONS FROM FIELD INSPECTIONS (ESOFIN) AND A SCREENING MODEL FOR ODOUR DISPERSION (SMOD) U. Janicke 1, L. Janicke 1, U. Hartmann 2 1 Janicke Consulting, Dunum, Germany 2 Landesamt
More informationLAGRANGIAN PARTICLE MODELLING FOR REGULATORY PURPOSES A SURVEY OF RECENT DEVELOPMENTS IN GERMANY
LAGRANGIAN PARTICLE MODELLING FOR REGULATORY PURPOSES A SURVEY OF RECENT DEVELOPMENTS IN GERMANY U. Janicke, L. Janicke Janicke Consulting, Dunum, Germany INTRODUCTION Dispersion modelling using a Lagrangian
More informationOdour Regulation in Germany an improved system including odour intensity, hedonic tone and odour annoyance
Odour Regulation in Germany an improved system including odour intensity, hedonic tone and odour annoyance Ralf Both*; Eckehard Koch** North Rhine-Westphalia State Environment Agency, Wallneyer Str. 6,
More informationIntroduction and Agenda
Introduction and Agenda Dr. Joachim Peschke, HU Dr. Dominik Wildanger, HLNUG 1 Agenda Time Topic 10:30 10:40 Introduction 10:40 11:00 Overview of European Standard for CEMS and type testing of an AMS (QAL
More informationDevelopment and Technology Assessment of the Analytical Performance of an Eight Position Dynamic Olfactometer
115 A publication of CHEMICAL ENGINEERING TRANSACTIONS VOL. 40, 2014 Guest Editor: Renato Del Rosso Copyright 2014, AIDIC Servizi S.r.l., ISBN 978-88-95608-31-0; ISSN 2283-9216 The Italian Association
More informationMeasurement Report LIFE10 ENV/FI/059
Measurement Report LIFE10 ENV/FI/059 Air pollution control measurement of the workplace atmosphere and testing of emission-reducing prototypes from the project partners Nederman Filtration GmbH and Reinluft
More informationAIR QUALITY ASSESSMENT FOR TAYLOR STANLEY MARKETING PTE LTD 71, TANNERY LANE #-7-07, CITY INDUSTRIAL BUILDING SINGAPORE
Our Ref: ATS/IH/84/05KKL Date: 26 August, 2005 Page 1 of 33 AIR QUALITY ASSESSMENT FOR TAYLOR STANLEY MARKETING PTE LTD 71, TANNERY LANE #-7-07, CITY INDUSTRIAL BUILDING SINGAPORE 347807 Date of Survey
More informationAssessing odour impact in the field: A comparison of grid and plume measurements
Assessing odour impact in the field: A comparison of grid and plume measurements PRESENTER: Christine West Emission Assessments Pty Ltd CONTACT DETAILS: Phone: 08 9494 2958 Email: christine@eapl.net.au
More informationDetermination and assessment of odour in ambient air. (Guideline on odour in ambient air / GOAA) dated 13 th May, with background information
Determination and assessment of odour in ambient air (Guideline on odour in ambient air / GOAA) dated 13 th May, 1998 with background information and interpretation to the GOAA issued 7 th May, 1999 Translation
More informationOdours and their effects on residents - How to measure and regulate odour impact
North Rhine-Westphalia State Environment Agency Odours and their effects on residents - How to measure and regulate odour impact FIXED ON NITROGEN Casa Science Symposium on Nitrogen September 27-29, 2006
More informationEmission Testing June 2014 Ingal Civil Products Minto Plant
Page: 1 of 8 57-65 Airds Rd MINTO NSW 2566 June 2014 Minto Plant Dear Amit, Tests were performed 17 June 2014 to determine emissions to air from 2 locations at the Minto plant of. LICENCE COMPARISON...
More informationECN/ORBIT e.v. Odour Management Workshop 2003 Pres. No. 10 "Olfactometry - its application and limits" - Frans Vossen
1 st International ECN Workshop on effective odour management in Biological Waste treatment plants OLFACTOMETRY: I T S APPLICATIONS AND IT S LIMIT S; THE EUROPEAN S TANDARD: EN 13725 By Frans Vossen (PRA
More informationDispersion Modeling Approach to Assess the Odour Impact from an Industrial Source at Residential Buildings in Urban Areas
Dispersion Modeling Approach to Assess the Odour Impact from an Industrial Source at Residential Buildings in Urban Areas Attilio Poli Envirosolutions & Consulting, Singapore Better Air Quality 2012 Hong
More informationOdour studies and health risk assessment: two complementary approaches in response to residents complaints
Air Pollution XV 449 Odour studies and health risk assessment: two complementary approaches in response to residents complaints G. Deiber, J. Boudaud & L. Pourtier EOG, France Abstract In this paper we
More informationProject Summary Report
Summary Report : Odour measurement and assessment, evaluation of odour treatment technologies 1. Background Gas phase samples are often collected from operating sewerage systems during investigations intended
More informationIndex. Introduction. history
Index Introduction history 1 Activities and capacities dynamic olfactometry correlation between odor concentration and pollutants electronic noses hedonicity evaluation verification of odor proper level
More informationCertificate: / 20 August 2013
Test report: 936/21219819/A of 11 March 2013 Initial certification: 23 July 2013 Date of expiry: 22 July 2018 Publication: BAnz AT 23 July 2013 B4, chapter III, No. 1.1 Approved application The tested
More informationPractical Odour assessment. Nigel Gibson
Practical Odour assessment Nigel Gibson Odour - the problem The process of concern Local residents 1 Topics covered Complaints Off-site survey Odour/odorant sampling Odour/odorant measurement Odour assessment
More information>>> Product and material testing. >>> Environmental odour management. >>> Calibration, Proficiency, Testing, Reference Material
European standardisation of ofdour measurement: the state of play of CEN/TC264/WG2 Olfactometry and WG41 Instrumental Odour Monitoring by Ton van Harreveld ARPA workshop, Trieste, Italy, February 19, 2018
More informationAmbient Air Quality Monitoring Update, Kirby Misperton A Wellsite, KM8 Production Well
Ambient Air Quality Monitoring Update, Kirby Misperton A Wellsite, KM8 Production Well. Prepared for: Third Energy UK Gas Ltd. Document Control Page Client Third Energy UK Gas Ltd. Document Title Ambient
More informationCertificate: / 29 April / /B of 08 December 2006 Addendum 936/ /C of 28 September 2013
Test report: Initial certification: 01 April 2014 Date of expiry: 31 March 2019 Certificate: 936/21205818/B of 08 December 2006 Addendum 936/21221709/C of 28 September 2013 Publication: BAnz AT 01 April
More informationPRODUCT CONFORMITY CERTIFICATE
PRODUCT NFORMITY CERTIFICATE This is to certify that the MCS100 E CD Multi-Component Analyser manufactured by: SICK MAIHAK GmbH Dr Zimmermann Straße 18 88709 Meersburg Germany has been assessed by Sira
More informationPadua, 21 st January 2015
ODOUR MEASUREMENT TECHNIQUES Maurizio Benzo Padua, 21 st January 2015 ODOUR ANALYSIS TECHNIQUES CHEMICAL ANALYSIS SENSORIAL ANALYSIS GC-MS GC-FID e-nose GC-O OLFACTOMETRY FIELD SURVEY COMBINED ANALYSIS
More informationAn Odor Index Scale for Policy and Decision Making Using Ambient and Source Odor Concentrations
An Odor Index Scale for Policy and Decision Making Using Ambient and Source Odor Concentrations Authored by: Charles M. McGinley, P.E. St. Croix Sensory, Inc. And Michael A. McGinley, P.E. St. Croix Sensory,
More informationScope of application. Definitions. Translation from Finnish Legally binding only in Finnish and Swedish Ministry of Social Affairs and Health
Translation from Finnish Legally binding only in Finnish and Swedish Ministry of Social Affairs and Health Decree of the Ministry of Social Affairs and Health on Health-related Conditions of Housing and
More informationFpollutant-free zero air for analytical
Ambient Air Quality Monitoring System AQMS-100 Zero Air Generator PI AQMS-100 provides ultra pure Fpollutant-free zero air for analytical purpose. Remote monitoring and configuration can also be achieved
More informationOlfactometry Precision and Real World Decision Making
Olfactometry Precision and Real World Decision Making Authored by: Charles M. McGinley, P.E. St. Croix Sensory, Inc. And Michael McGinley, P.E. St. Croix Sensory, Inc. Presented at International Water
More informationMethods of sensory evaluation of odour
Methods of sensory evaluation of odour & 50 m 3 test facility at Arlon laboratory Anne-Claude ROMAIN, Jacques NICOLAS, Christophe DEGRAVE Department "Environmental Sciences and Management" Research group
More informationODOUR MEASUREMENT IN WASTEWATER TREATMENT PLANT USING BOTH EUROPEAN AND JAPANESE STANDARDIZED METHODS: CORRELATION AND COMPARISON STUDY
Global NEST Journal, Vol 18, No 4, pp 728-733, 2016 Copyright 2016 Global NEST Printed in Greece. All rights reserved ODOUR MEASUREMENT IN WASTEWATER TREATMENT PLANT USING BOTH EUROPEAN AND JAPANESE STANDARDIZED
More informationCertificate: / 29 April / /A1 of 05 January 2006, Addendum 936/ /D of 04 October 2013
Test report: Initial certification: 01 April 2014 Date of expiry: 31 March 2019 936/21203248/A1 of 05 January 2006, Addendum 936/21221382/D of 04 October 2013 Publication: BAnz AT 01 April 2014 B12, chapter
More informationLab 7 Measurement of Ozone
Georgia Institute of Technology School of Earth and Atmospheric Sciences EAS 4641 Spring 2007 Lab 7 Measurement of Ozone Purpose of Lab 7: In this lab you will measure the ambient concentration of ozone
More informationSaskatchewan s Air Modelling and Odour Guidelines Imran Maqsood, Ph.D., P.Eng. Ministry of Environment
Saskatchewan s Air Modelling and Odour Guidelines Imran Maqsood, Ph.D., P.Eng. Ministry of Environment Air Quality in Saskatchewan, Saskatoon January 17, 2014 Outline Part 1: Air Modelling Guideline Part
More informationComparison of Methods Used to Measure Odour at Wastewater Treatment Plant Fencelines
Comparison of Methods Used to Measure Odour at Wastewater Treatment Plant Fencelines Jay R. Witherspoon and Jennifer L. Barnes CH2M HILL, Inc. 777 108 th Avenue NE, Suite 800 Bellevue, WA, USA 98004-5118
More informationAPPENDIX 15 OCF Meteorological Data and Process Data (8 pages)
APPENDIX 15 OCF Meteorological Data and Process Data (8 pages) AECOM Canada, Odour Testing Program at the York Region SeC Trunk Sewer OCF Phase 1b, Summer, 2015, Report #26182-2 Appendix 15 OCF Meteorological
More informationReference flue gas analyzer
Reference flue gas analyzer testo 360 Portable reference analyzer for industrial flue gases O2 NO NO2 NOX SO2 CO2 %H2O Reference flue gas analyzer testo 360-3 testo 360 flue gas analyzer, approved, without
More information3. Researches and Developments on Odor Measurement
3. Researches and Developments on Odor Measurement Development of the Next Generation Dynamic Olfactometer Dynascent John Jiang EnvironOdour Australia Pty Ltd, Sydney, Australia j.jiang@environodour.com.au
More informationEXPERIMENTAL INVESTIGATION OF NITROGEN DIOXIDES ADSORPTION FROM CABIN AIR BY ACTIVATED CHARCOAL AIR FILTERS
EXPERIMENTAL INVESTIGATION OF NITROGEN DIOXIDES ADSORPTION FROM CABIN AIR BY ACTIVATED CHARCOAL AIR FILTERS Mesut GÜR Sakarya University Adnan GÖRGÜLÜ Duisburg University Abstract The popularity of combination
More informationDiegmann Volker, 1 Florian Pfäfflin 1 and Sabine Wurzler 2
AIR QUALITY ASSESSMENT IN THE EUROPEAN MEGA CITY RUHR AREA: EFFECTS OF A LOW EMISSION ZONE Diegmann Volker, 1 Florian Pfäfflin 1 and Sabine Wurzler 2 1 IVU Umwelt GmbH, Freiburg, Germany 2 NRW State Agency
More informationCERTIFICATE of Product Conformity (QAL1 )
ÄTÜVRheinland Precisely Right. CERTIFICATE of Product Conformity (QAL1 ) Certificate No.: 0000050628 Certified AMS: Manufacturer: Test lnstitute: Mercury Freedom System for Hg Thermo Fisher Scientific
More informationCertificate: / 29 April / /C1 of 05 January 2006 Addendum 936/ /B of 21 September 2013
Test report: Initial certification: 01 April 2014 Date of expiry: 31 March 2019 Certificate: 936/21203248/C1 of 05 January 2006 Addendum 936/21221382/B of 21 September 2013 Publication: BAnz AT 01 April
More informationAIR HYGIENE TEST SUITABLE FOR ALLERGIC PEOPLE
Scope of Test and Assessment Criteria for the Issue of the TÜV NORD Test Mark INDOOR AIR HYGIENE TEST SUITABLE FOR ALLERGIC PEOPLE for Indoor Air Purifiers (as at 08/13) I General The aim of these tests,
More informationDocument No.: NOKETL / IPPC Licence No.: W
Report Title Company address Stack Emissions Testing Report Commissioned by Facility Name Contact Person Air Emissions Compliance Monitoring Emissions Report Air Scientific Ltd., 32 DeGranville Court,
More informationAbstract. 1 Introduction
Transactions on Ecology and the Environment vol 8, 996 WIT Press, www.witpress.com, ISSN 7- Combining reversed modelling and odour detection campaigns to determine the odour emission from a landfill for
More informationGuido Baum Dr. Peter Wilbring
Determination of CO 2 and N 2 O emissions with CEM systems within the scope of greenhouse gas trading New regulation for the continuous measurement of CO 2 and N 2 O mass flow - requirements for the installed
More informationField Odor Monitoring and Enforcement
Field Odor Monitoring and Enforcement Authored by: Charles M. McGinley, P.E. St. Croix Sensory, Inc. Michael A. McGinley McGinley Associates, P.A. Presented at The 22 nd Annual Hawaii Water Environment
More informationGENERAL TESTING AND REPORTING REQUIREMENTS
GENERAL TESTING AND REPORTING REQUIREMENTS Ohio EPA requires that an Ohio Intent to Test ( ITT ) form be filed with the appropriate Ohio EPA representative at least 30 days (or more if required by regulation)
More informationABE 482 Environmental Engineering in Biosystems. November 14 Lecture 30
ABE 482 Environmental Engineering in Biosystems November 14 Lecture 30 Today Air quality issues Odours Greenhouse gases (GHG) Dispersion of gases Measuring source strength Calculating gas emissions Emission
More informationA comparative and Critical Evaluation of Different Sampling Materials in the Measurement of Odour Concentration by Dynamic Olfactometry
A publication of CHEMICAL ENGINEERING TRANSACTIONS VOL. 30, 2012 Guest Editor: Renato Del Rosso Copyright 2012, AIDIC Servizi S.r.l., ISBN 978-88-95608-21-1; ISSN 1974-9791 The Italian Association of Chemical
More informationPRODUCT CONFORMITY CERTIFICATE
PRODUCT CONFORMITY CERTIFICATE This is to certify that the PG-350E Multi-component Gas Analyser Manufactured by: Horiba Europe GmbH Julius Kronenberg Straße 9 42799 Leichlingen Germany Has been assessed
More information1000 Olfactometry Analyses and 100 TD-GC/MS Analyses to Evaluate Methods for Reducing Odour from Finishing Units in Denmark
1 Olfactometry Analyses and 1 TD-GC/MS Analyses to Evaluate Methods for Reducing Odour from Finishing Units in Denmark M. Lyngbye, M.J. Hansen, A.L. Riis, T.L. Jensen and G. Sørensen The National Committee
More informationIssues around field measurements with electronic noses : low concentration and specificity of odorous compounds Jacques NICOLAS Julien DELVA -
Issues around field measurements with electronic noses : low concentration and specificity of odorous compounds Jacques NICOLAS Julien DELVA - Anne-Claude ROMAIN Department of Environmental Sciences and
More informationOdor measurement in Japan
Odor measurement in Japan Takaya Higuchi Department of Civil and Environmental Engineering, Yamaguchi University 2-16-1, Tokiwadai, Ube, Yamaguchi, 755-8611 Japan E-mail: takaya@yamaguchi-u.ac.jp KEYWORDS
More informationAmbient Air Quality Monitoring Baseline Report, Kirby Misperton A Wellsite, KM8 Production Well
Ambient Air Quality Monitoring Baseline Report, Kirby Misperton A Wellsite, KM8 Production Well. Prepared for: Third Energy UK Gas Ltd. Document Control Page Client Third Energy UK Gas Ltd. Document Title
More informationFigure 1. Design of the vertical biofilters.
Biotechniques for Air Pollution Control Proceedings of the II International Congress on Biotechniques for Air Pollution Control. A Coruña, Spain, October 3-5, 2007. Removal of odour and ammonia in ventilation
More informationEMISSION MEASUREMENT TECHNICAL INFORMATION CENTER NSPS TEST METHOD. Method 10 - Determination of Carbon Monoxide Emissions from Stationary Sources
EMISSION MEASUREMENT TECHNICAL INFORMATION CENTER NSPS TEST METHOD Method 10 - Determination of Carbon Monoxide Emissions from Stationary Sources 1. PRINCIPLE AND APPLICABILITY 1.1 Principle. An integrated
More informationMEASUREMENT OF ODOUR EMISSIONS FROM HOG OPERATIONS IN MANITOBA
MEASUREMENT OF ODOUR EMISSIONS FROM HOG OPERATIONS IN MANITOBA Final Report Submitted to Manitoba Livestock Manure Management Initiative Inc. and Triple S Hog Manure Management Initiative by Q. Zhang 1
More informationWhat s that funky smell from my product? EURL-FCM ISPRA 29th Nov 11
What s that funky smell from my product? EURL-FCM ISPRA 29th Nov 11 1 The work of ISO TC146 for the standardisation of sensory tests A support for the accreditation of material odour testing Dr Olivier
More informationMake Submission. Mr Stuart Keer-Keer. Beckenham Christchurch Proposed Canterbury Air Regional Plan. Submission Type. Version.
Make Submission. pcarp-936 1/05/15 7:46 AM 13 MANDATORY INFORMATION ( View ) 0.2 To Be Heard Please select the appropriate option from the following: I DO NOT wish to be heard in support of my submission;
More informationDRAINING OF SLURRY PITS - A SIMPLE WAY TO REDUCE EMISSIONS FROM PIG HOUSING UNITS
This is not a peer-reviewed article. International Symposium on Air Quality and Manure Management for Agriculture CD-Rom Proceedings of the 13-16 September 21 Conference (DoubleTree Hotel, Dallas Texas)
More informationPRODUCT CONFORMITY CERTIFICATE This is to certify that the
PRODUCT CONFORMITY CERTIFICATE This is to certify that the Babcock & Wilcox Model 2008-1 CEMS (EN 15267-3 Standard) & Babcock & Wilcox Stack Flow Monitor Model 110 manufactured by: Babcock & Wilcox Company
More informationNovember 6, VIA REMIR Online Reporting. Metro Vancouver, Legal and Legislative Services Department 4330 Kingsway Burnaby, BC V5H 4G8
November 6, 2017 VIA REMIR Online Reporting Metro Vancouver, Legal and Legislative Services Department 4330 Kingsway Burnaby, BC V5H 4G8 Attention: Brendon Smith RE: AIR PERMIT GVA1088 STORAGE PILES Harvest
More informationA controlled laboratory evaluation of the scale prevention properties of next-scalestop media.
Water Technology Center Karlsruhe Water Laboratory Karlsruhe, Germany A controlled laboratory evaluation of the scale prevention properties of next-scalestop media. Testing performed by the German Technical
More informationMATERIAL SAFETY DATA SHEET (According to EC Commission Directive 2001/58/EC)
1.- Product Name Registered name: Description: Anticorrosive pigment preparation Manufacturer: NUBIOLA GRUPO Head Office: Gran Vía Corts Catalanes 648 08010 BARCELONA Telephone: 0034-93 - 343 57 50 Emergency
More informationQAL3 methods for different measurement principles from the point of view of AMS manufacturers, test houses and plant operators
QAL3 methods for different measurement principles from the point of view of AMS manufacturers, test houses and plant operators Mr. Guido Baum TÜV Rheinland Energie und Umwelt GmbH Am Grauen Stein, 51105
More informationSPARK TM MOISTURE ANALYZER VALIDATION Performed in Conjunction with Air Products and Chemicals, Inc.
SPARK TM MOISTURE ANALYZER VALIDATION Performed in Conjunction with Air Products and Chemicals, Inc. I. Overview: Tiger Optics now offers a new low-cost, powerful platform, based on its world-renowned
More informationPRODUCT CONFORMITY CERTIFICATE
PRODUCT NFORMITY CERTIFICATE This is to certify that the PG-250 Portable Gas Analyser Pre-conditioner PS200 manufactured by: Horiba Limited Miyanohigashi Kisshoin Minami-Ku Kyoto Japan has been assessed
More informationFIDAS FINE DUST MONITORING SYSTEMS. Fidas the world s only certified optical fine dust measurement system with single particle analysis for PM 2.
FIDAS FINE DUST MONITORING SYSTEMS Fidas the world s only certified optical fine dust measurement system with single particle analysis for PM 2.5 PM 10 1 APPLICATIONS Measurements at workplaces and in
More informationFOUNDRY-MASTER Pro. First class laboratory optical emission spectrometer for complete professional metal analysisoes
First class laboratory optical emission spectrometer for complete professional metal analysisoes OES Engineered for high performance and reliability, the, with its innovative optical system and extended
More informationPRODUCT CONFORMITY CERTIFICATE
PRODUCT NFORMITY CERTIFICATE This is to certify that the G-CEM 4000 In-situ Multigas Analyser manufactured by: DEL International Ltd Station Building Station Road Bakewell Derbyshire DE45 1GE UK has been
More informationPRODUCT CONFORMITY CERTIFICATE
PRODUCT CONFORMITY CERTIFICATE This is to certify that the Gasmet Continuous Mercury Monitoring System (CMM) Manufactured by: Gasmet Technologies Oy Pulttitie 8 A 1 FI-00880 Helsinki, Finland has been
More informationDecember 2014 Sampling of Odour and VOC Emissions at Harvest Power s Richmond, BC Facility Revision B
December 2014 Sampling of Odour and VOC Emissions at Harvest Power s Richmond, BC Facility Revision B Prepared for: Harvest Power, 7028 York Road, Richmond, BC V6W 0B1 Prepared by: Envirochem Services
More informationCASE STUDY : chroma S SULFUR COMPOUNDS ANALYSIS (H2S and CS 2, 0/300ppm) FOR EMISSION APPLICATION IN A PAPER MILL
EUROPE AIRMOTEC ag SA 15 rue d'artiguelongue F-33240 SAINT-ANTOINE (BORDEAUX) Tel : +33 (0)557 940 626 Fax : +33 (0)557 940 620 AMERICA CHROMATOTEC Inc. 1833 Egret Bay Blvd, Suite 270, HOUSTON TX 77058
More informationQuality assurance in pipe-jacking
Pipe-jacking Quality assurance in pipe-jacking During pipe-jacking, the external loads from bedding and curvature of the pipeline remains concealed so far. Goal of the IKT research focus pipe-jacking was
More information33101 TAMPERE.
Measurement of odours and hazardous gaseous emissions from steel foundry 16.-17..5.2013 Project 10745Y12A 15.10.2013 Kuokkamaantie 4 P.O. BOX 428 33101 TAMPERE Tel +358 3 2680 111 Fax +358 3 2110 106 www.ax.fi
More informationParticulate Emission Monitor Spot Correlations. Camden Power Station Stacks 1, 2 & 3 May 2011 RPHP147
Particulate Emission Monitor Spot Correlations Camden Power Station Stacks 1, 2 & 3 May 2011 P.O. Box 2459 Noordheuwel ext 4 Krugersdorp 1756 Vat No. 4670254459 STACKLABS ENVIRONMENTAL SERVICES 10 Chisel
More informationEmissions Monitoring: Talinga GPF
Emissions Monitoring: Talinga GPF Origin Energy 144 Montague Road West End QLD, 4101 November 2015 Issued: 9 November 2015 Prepared by: Air Noise Environment ABN: 13 081 834 513 This document is issued
More informationWATER CENTRE. Consulting Research Training. Affiliated Institute of the. Member of DVGW Alliance of Institutes
WATER CENTRE Consulting Research Training Affiliated Institute of the Member of DVGW Alliance of Institutes KEEPING THE RIVER CLEAN! MINIMIZING IODINATED CONTRAST MEDIA IN SURFACE WATERS IN MÜLHEIM, GERMANY
More informationBuilding a Bigger, Better Zero Air Generator Certification Process
Building a Bigger, Better Zero Air Generator Certification Process By: Dr. David Sodeman, Ph.D. and Mr. David Roque San Diego Air Pollution Control District 1 The Needs for a Zero Air Generator Certification
More informationHeated FID OVF Portable THC/TVOC Analyzer
Heated FID OVF-3000 Portable THC/TVOC Analyzer The OVF-3000 is light weight and portable, competitively priced compact and fully heated FID (HFID) based total hydrocarbon analyzer for high accuracy, sensitivity
More informationFacility Location: Castlefarm Centre and Clonmel Rd, Mitchelstown, Co. Cork Office: Trim Rev.No: 1
Report Title Company address Stack Emissions Testing Report Commissioned by Facility Name Contact Person EPA Licence Number Licence Holder Stack Reference Number Air Emissions Compliance Monitoring Emissions
More informationComparison Continuous Emission Monitoring Techniques
PRODUCT DATASHEET: Comparison Continuous Comparison Continuous Emission Monitoring Techniques Overview The requirements for continuous emission monitors has changed significantly over the last 30 years.
More informationH ESTIMATING ODOUR IMPACT RANGE OF SELECTED WASTEWATER TREATMENT PLANT FOR WINTER AND SUMMER SEASONS IN POLISH CONDITIONS USING CALPUFF MODEL
H15-101 ESTIMATING ODOUR IMPACT RANGE OF SELECTED WASTEWATER TREATMENT PLANT FOR WINTER AND SUMMER SEASONS IN POLISH CONDITIONS USING CALPUFF MODEL Izabela Sówka, Maria Skrętowicz, Piotr Sobczyński, Jerzy
More informationOdour Emission Report Summary odour testing exercise February 2018
Odour Emission Report Summary odour testing exercise 16 21 February 2018 1 INTRODUCTION The principal objectives of the tests were to measure odour emission concentrations from the stack and to determine
More informationDeutsches Institut für Bautechnik
Deutsches Institut für Bautechnik Anstalt des öffentlichen Rechts 10829 Berlin, Kolonnenstraße 30 L Tel.: +49(0)30-78730-0 Fax: +49(0)30-78730-320 e-mail: dibt@dibt.de Ermächtigt und notifiziert gemäß
More informationClassification of Indoor Climate, Construction, and Finishing Materials
Classification of Indoor Climate, Construction, and Finishing Materials 0. Seppiinen Department of Mechanical Engineering, Helsinki University of Technology, Espoo, Finland Abstract Good indoor climate
More informationCommon CEMS RATA Failures and Risks. Paula Metz Alliance Source Testing, LLC Technical Services Assistant Manager
Common CEMS RATA Failures and Risks Paula Metz Alliance Source Testing, LLC Technical Services Assistant Manager Introduction Stack Testing is a labor and time intensive process and requires thorough planning
More informationOdour control at WWTP s- Theory and Practice
Odour control at WWTP s- Theory and Practice By Dr. Brian Sheridan The Institute of Engineers of Ireland Seminar, Clyde Rd, Dublin 4 Odour Monitoring Ireland Unit 32 DeGranville Court, Dublin Road, Trim,
More informationAn Introduction to Air Quality
An Introduction to Air Quality Learning Goals "We came all this way to explore the Moon, and the most important thing is that we discovered the Earth - William Anders After this lesson, you will be able
More informationTitle: Standard Operating Procedure for the Continuous Measurement of Ambient PM using a Beta Attenuation Monitor
Monitoring Parameter: Particulate Matter (PM) Revision No: Draft Revision Date: 07 March, 2018 Title: Standard Operating Procedure for the Continuous Measurement of Ambient PM using a Beta Attenuation
More informationRoad Tunnel Atmosphere Monitoring Systems TunnelCraft 3 - Air Quality Monitor Continuous measurement of NO2 and Visibility in road tunnels
TunnelTech 404 CODEL NO2, and Visibility Air Quality Monitor Road Systems TunnelCraft 3 - Air Quality Monitor Continuous measurement of NO2 and Visibility in road tunnels High accuracy determination of
More informationField-tests at Kiviõli Keemiatööstus OÜ oil-shale processing plant in Kiviõli, Estonia
Field-tests at Kiviõli Keemiatööstus OÜ oil-shale processing plant in Kiviõli, Estonia Introduction The field-tests for plasma-treatment of exhaust gases were carried out in several different sites of
More informationWater requirement of cement, W 180 A practical test method
- 1 - of cement, W 180 A practical test method 1. INTRODUCTION Jouni Punkki, Dr.Tech., Development Engineer Parma Betonila Oy P.O. Box 76, FIN-03101 Nummela, Finland E-mail: jouni.punkki@parmabetonila.fi
More informationPRODUCT CONFORMITY CERTIFICATE
PRODUCT CONFORMITY CERTIFICATE This is to certify that the D-R 300-40 Dust Monitor Manufactured by: DURAG GmbH Kollaustrasse 105 22453 Hamburg Germany Has been assessed by Sira Certification Service And
More informationPRODUCT CONFORMITY CERTIFICATE
PRODUCT CONFORMITY CERTIFICATE This is to certify that the Procal 2000 Series Continuous Emission Monitor With Procal 1000 Control Unit (formerly known as ACWn) Manufactured by: Parker Hannifin Manufacturing
More informationAtholville Air Quality Report Mobile Air Quality Monitoring Program
Atholville Air Quality Report 2011 Mobile Air Quality Monitoring Program Department of Environment and Local Government June 2012 1.0 Executive Summary The AV Cell Pulp Mill operates two air quality monitoring
More informationEvaluation by Competent Authorities
LANXESS Deutschland GmbH Chlorophene 07/2007 ACTIVE SUBSTANCE RESIDUES IN ANIMAL AND HUMAN BODY FLUIDS AND TISSUES JUSTIFICATION FOR NON-SUBMISSION OF DATA Official use only Other existing data [ ] Technically
More informationThis document is a preview generated by EVS
INTERNATIONAL STANDARD ISO 13199 First edition 2012-10-15 Stationary source emissions Determination of total volatile organic compounds (TVOCs) in waste gases from non-combustion processes Nondispersive
More informationThe most modern treatment provides the best drinking water
Drinking water The most modern treatment provides the best drinking water Process measuring and control technology technology for Germany s largest nanofiltration plant Last year, a nanofiltration plant
More informationB Recommended hole pattern: [mm] SSt. SSt SSt PLD. SSt PLD SSt. SSt. SSt SSt
A Dimensions: [mm] B Recommended hole pattern: [mm] D Absolute Maximum Ratings (Ambient Temperature 25 C): Properties Test conditions Value Unit Power dissipation P Diss 90 mw Peak Forward Current duty/10@1khz
More informationDr. Peter Gäng. FilT Eq Filtration Testing Equipment & Services GmbH. Amthausstr. 14, D Karlsruhe, Germany
Testing of Cleanable Filter Media - Status and Perspectives Status of ISO 11057:2011 - "Test method for filtration characterization of cleanable filter media" Dr. Peter Gäng FilT Eq Filtration Testing
More information