1 Outsourced Water Treatment Plant for Boiler Make-Up Water: Case Study RUSSELL HOURIGAN, GABRIEL NICOLAIDES, Ontario Power Generation, Pickering, Ontario and MICHAEL DEJAK, Eco-Tec Inc., Pickering, Ontario IWC ABSTRACT: An outsourced Water Treatment Plant featuring down flow micro media filters, reverse osmosis units and short bed demineralizers designed to produce 66 l/s of makeup water for eight (8) functioning reactor-turbine units has been running for almost 4 years. Individual equipment and overall plant performance is assessed and plant optimization discussed. INTRODUCTION Ontario Power Generation s Pickering Nuclear Generating Station (PNGS) is an eight-unit nuclear station located near the shore of Lake Ontario, in the City of Pickering, Ontario, Canada. The original set of four (A-side) units were placed in commercial service in the early 1970 s, the second set of four units (B-side) were placed in commercial service in the mid-1980 s. The generating units are rated at a Net Electrical Output of 515 MW each. The original PNGS s water treatment plant (WTP) was based on conventional water treatment process technology and included clarification, sand filtration, activated carbon and ion exchange. The original water treatment plant was aging, required a high degree of maintenance, and was limited in its ability to produce demineralized water of sufficiently high quality. In 1999, Ontario Power Generation (OPG) conducted a study of the available alternatives, and decided to build a new outsourced WTP. This was OPG s first experience at contracting out WTP operation. OPG awarded a 10-year build, own, operate, and maintain WTP contract to a team consisting of a Prime Contractor and Eco-Tec Inc (hereafter referred to as the O&M Company/Team). OPG supplied the building; the Prime Contractor owns the WTP equipment, and Eco-Tec Inc., a local, Pickering-based company, supplied the equipment and is operating the WTP under contract to the Prime Contractor. The new WTP was designed, built, installed and commissioned in eight (8) months, and was available for service in October The following aspects of the WTP project will be discussed in this paper: Site selection Inlet water characteristics Demineralized water specifications WTP process description Plant waste management System automation and monitoring Operating experience Summary Positive Experiences/Lessons Learned SITE SELECTION OPG considered the following raw water sources as possible influents to the WTP [1]: Condenser cooling water return (CCWR) Service water Domestic water Of these three options, the quality of service water and CCWR are approximately the same, i.e. they are both very similar to lake water, with the difference that both of these streams have somewhat higher temperatures (i.e. 5 10ºC) higher than lake water. The CCWR stream was the preferred choice since it represented the least potential for contamination. The potential for CCWR contamination with oil from a lube oil system leak and its impact on the WTP raw water quality are rather small. Based on the very large dilution factor and the large CCWR flow rate of 190,000 l/s per unit, more than 100 l/hr of oil must be spilled into the CCWR in order to reach the maximum allowable concentration of oil in the RO feed water of 1 mg/l. The likelihood of this situation occurring was deemed to be insignificant. A similar case could also be made for the impact of boiler blow-down, as
2 boiler blow-down volumes are also very small relative to the CCWR flow-rate. It should also be noted that the higher temperature of the CCWR stream represents a major advantage over the use of raw lake water, since it translates into > 25% reduction in the overall WTP plant size and its capital cost. The use of domestic water as feed to the new WTP was considered, but was not pursued by the PNGS s Design Team. The main deterrents to using domestic water were: Estimated additional operating cost of $600,000/year to purchase domestic water from the municipality Additional infrastructure would have to be installed to supply the domestic water Concerns regarding the presence of trihalomethanes in the domestic water and ability of the WTP process to remove them OPG decided to locate the WTP outside of the security perimeter on the east side of the station, over the outfall of the PNGS s-b Condenser Cooling Water Discharge Channel. The WTP utilizes CCWR -water from the discharge ducts of the PNGS s Units 7 and 8. This site was selected because it offered the following advantages: Reliable, low-cost source of water Warm raw water for improved RO efficiency (i.e. up to 10ºC higher temperature) Close proximity to power, sewer, and demineralized water header tie-ins Location allows vendor ready access and permits equipment installation and retrofits as commercial modifications Use of existing CCWR outfall structure for raw water supply pumps The location of the PNGS s WTP is as depicted in Figure 1 and 2. The complete system including all equipment, storage tanks, piping, instrumentation and controls is housed inside a 620 m 2 (6,700 ft 2 ) building. This is quite compact for a system of 66 l/s, (1050 gpm) capacity. By contrast, the original water treatment plant occupied approximately 1,279 m 2 (13,770 ft 2 ). Figure 1: Aerial View of the Pickering Nuclear Generating Station Water Treatment Plant Water Treatment Plant Figure 2: Water Treatment Plant INLET WATER CHARACTERISTICS OPG provided the following Raw Water Analysis and the Lake Ontario Water Temperature Data in Table I as a basis for design of the water treatment plant [2]: Source: Lake Ontario Water at the PNGS. Characteristics: ph Turbidity (NTU) Conductivity (ms/m) OH Alkalinity (ppm) < 5.0 CO 3 Alkalinity (ppm) < 5.0 HCO 3 Alkalinity (ppm) Calcium (ppm) Magnesium (ppm) Sodium (ppm) Potassium (ppm) Sulphate (ppm) Chloride (ppm) Nitrate (ppm) Total Silica (ppm SiO 2 ) Reactive Silica (ppm SiO 2 ) TIC (ppm) TOC (mg/l) Silt Not quantified (variable quantity) Table I: Lake Ontario Pickering Nuclear Generating Station s Mean Monthly Water Temperatures [3] Temperature o C Surface Ambient 8 m Depth 12 m Depth January February March April May June July August September October November December
3 DEMINERALIZED WATER SPECIFICATIONS The demand of demineralized water is dependent on the operating mode of the eight generating units in the station, i.e. unit shut down, unit start-up, unit on power, etc. The average flow was estimated to be between 35 l/s to 53 l/s. The water treatment plant has been designed to produce the following [4]: 1. Flow: Net product during normal operation l/s Net product during peak operation 66 l/s 2. Quality Specific conductivity (at 25ºC) 0.06 µs/cm Total silica (reactive and colloidal) 2.0 µg/kg Sodium 0.2 µg/kg Total organic carbon 10 µg/kg Total dissolved and suspended solids 100 µg/kg Total chloride (per ASTM D5542) 0.8 µg/kg Total sulphate (per ASTM D5542) 1.8 µg/kg WTP PROCESS DESCRIPTION The water treatment process is illustrated in Figure 3. The basic process involves treating feed water by: 1. Direct filtration for suspended solids removal using a set of micro media backwashable filters. 2. Reverse osmosis for bulk ion removal and the separation of organic compounds. 3. Ion exchange polishing using short, compressed bed ion exchangers for final polishing of the water to the specified product water quality. DIRECT FILTRATION Feed water from the PNGS s condenser cooling return ducts is pumped to a set of three Micro Media Filters (see Figure 4 on the following page). Prior to the filters, coagulant (poly-aluminum chloride) is injected and mixed inline. The coagulant dosage is automatically controlled based on flow and feed turbidity, and is typically in the range of 1 5 ppm. The Micro Media Filters operate similar to a multimedia filter. Water flows downward through two layers of media in a pressure vessel. The upper layer of media is coarse anthracite while the lower layer is a proprietary fine media, which is much finer and denser than media commonly used in multimedia filters. Due to the very fine size of these media particles, the filter is able to remove very small-suspended solids with a very high efficiency. Technical details and operating parameters for this type of filter have been reported previously at this conference [5]. Filtrate quality from the filters is continuously monitored on-line for turbidity and typically falls in the range of NTU (see Figures 5 and 6 on the following page). Periodic manual sampling for silt density index (SDI) has been conducted and SDI values in the range of 2 5 have been obtained. The filtrate quality is maintained despite significant fluctuations in the feed water turbidity (3 100 NTU) caused by varying weather conditions over the lake. Using a patented operating feature known as backslip, the filters are able to maintain extended runs between backwashes even at relatively high turbidity conditions ( NTU). The filter backwash sequence is automatically initiated based on flow and pressure drop across a filter. Backwash is accomplished using filtered water directly from the remaining, in service, filters. During infrequent occasions when the demineralized water demand is high and the feed water turbidity is also very high, City Water is used to augment the filter-backwash. A cartridge filter is installed downstream of the Micro Media filters as a trap in the event of a filter lateral failure. The cartridge filters are rated at 10 microns and run for 4 6 months before replacement. Figure 3: The PNGS Water Treatment Process Schematic
4 Figure 4: Micro Media Filters Figure 5: Feed Water Turbidity Levels for OPG s Micro Media Filters for the months of January and February 2003 Figure 6: Filtrate Turbidity Levels for OPG s Micro Media Filters for the months of January and February 2003 REVERSE OSMOSIS - Prior to entering the reverse osmosis (RO) unit (see Figure 7), filtered water passes through an ultraviolet sterilization unit and acid is injected and mixed in-line. Ultraviolet light was selected as a sterilization technology instead of the more conventional method of chlorination because of evidence that chlorination would form tri-halomethanes (THM), which are not completely removed by reverse osmosis or ion exchange. This would compromise the system s ability to meet the 10 ppb TOC limit. Even if the TOC was within the 10 ppb limit, a significant portion of the TOC would be in the form of THM s and this would result in the release of chloride when the THM is decomposed in the boilers. Acid is injected into the filtered water to lower the ph and prevent scaling of the RO membranes. The reduced ph results in a shift of the carbonatebicarbonate-carbon dioxide equilibrium, increasing the concentration of carbon dioxide. Carbon dioxide is not rejected by the RO membranes, producing a permeate with high levels of carbon dioxide gas. The increased carbon dioxide levels result in an increased caustic consumption of the polishing demineralizers. However, a higher CO 2 level was deemed acceptable because the polishers could still produce the required water quality, and the overall chemical operating costs would be lower than the alternative approach of maintaining a more neutral water ph (thereby maintaining a lower carbon dioxide concentration) and using a polymeric antiscalant to control carbonate scale formation. The filtered and pretreated water then passes through a RO system arranged in a three parallel bank, single pass, two-stage configuration. The RO elements are thin film composite type. A clean-inplace system is used to clean one bank of elements at a time. Figure 7: Reverse Osmosis Unit
5 ION EXCHANGE - The RO permeate is collected in a storage tank and then drawn by one of two trains of ion exchange polishers. Each train consists of two polishers in series and is capable of treating 33 l/s (50%) of full flow on a net basis (see Figure 8). These polishers are not the traditional type consisting of mixed cation and anion resins. The polishers use short (15 cm tall), separate cation and anion resin beds with fine mesh resins packed under slight compression in a fixed column with no freeboard. Each polisher is a self-contained skid complete with resin bed, regeneration system, and controls. Regeneration consists of on-skid pumps drawing 93% sulphuric acid and 50% caustic soda directly from storage tanks and injecting them into DI water a few immediately before the inlet to the appropriate resin bed. Since the regeneration times are short (complete regeneration and return to service in 7 minutes), additional trains were not required. This type of ion exchange system and the principles of its operation have been described previously at this conference [6,7]. Compared with a traditional mixed bed polisher, this type of ion exchanger has a number of benefits: 1. Since the resins are fixed in separate beds, the equipment design and system operation is very simple. This allows for full system automation including unattended regeneration. By contrast, mixed bed systems have a more complex design and experience operational challenges related to the need for excellent separation of resins before each regeneration and thorough uniform mixing of the resins after each regeneration. While this may not be a challenge initially, as resins age, and their characteristics change, this can become increasingly more difficult. 2. Since the resins are fixed in the vessels with no freeboard, the possibility of flow channeling is eliminated and it is very simple to carry out counter-current regeneration. This results in a much more chemically efficient regeneration than that of mixed beds with the added advantage of a significantly lower regenerant chemical consumption. 3. It is possible to operate the resins in a column without freeboard due to the relatively low loading (about 10% of resin capacity), which in turns results in minimal shrinking and swelling of the resins due to changes in ionic form. The minimal shrinking and swelling of the resin beads also reduces the mechanical fatigue of the resin particles, which prevents breakage of resin beads and subsequent attrition losses and flow distribution problems. 4. The small resin volume in each vessel and low resin loading also result in very small waste volumes during regeneration. This feature enables the neutralization process to be carried out in small tanks. 5. The use of fine mesh resins results in a very high surface area despite the small volume of resin. This means that a greater proportion of exchange sites are at the surface of the resin particles. Since the rate of ion exchange is dependant on the rate of diffusion of ions to exchange sites within the porous structure of the resin particle, a greater proportion of surface exchange sites means that proportionately more exchange sites can be accessed rapidly through diffusion of ion through the liquid film around the resin particles rather than through the much slower process of intra-particle diffusion to access internal resin sites. Consequently, contact time required in the resin bed is short. This allows flow velocities of gpm/ft 2 and regeneration times as short as 40 seconds for cation bed regeneration and 1.5 minutes for anion bed regeneration. The rapid ion exchange kinetics also allow for very complete ion exchange to take place resulting in the ability to produce very high purity water without mixed beds. Pilot testing prior to the system design demonstrated that a single cation-anion polisher was capable of producing the specified water quality (specific conductivity < 0.06 µs/cm). Two were used in series in this system for redundancy. Another technology that has been more recently applied for polishing after RO is electrodeionization. While this technology has the benefit of eliminating the need for regenerant chemicals, experience reported at this conference has indicated that it may not be sufficiently robust to be used after a single pass RO system without risking irreversible fouling. The added cost and complexity of the pretreatment system required for operation of a reliable electrodeionization system eliminated this technology from consideration in this case. Figure 8: Polisher with Ion Exchange Technology
6 WASTE TREATMENT Wastes from the system include filter backwashes, RO reject and cleaning wastes, and ion exchange polisher regenerant wastes. The majority of the wastes are collected, ph adjusted, auto-sampled and discharged back to the lake. When the turbidity of the lake water feeding the WTP is above 6 NTU, the suspended solids concentration of the filter backwash water exceeds the discharge regulations. In order to ensure compliance under any condition, half of the filter backwash (source of suspended solids) is automatically discharged to the municipal sewer system rather than being discharged to the lake. All discharge data; including analysis of auto samples is recorded and reported to the environmental regulatory authority to confirm compliance with discharge regulations. SYSTEM AUTOMATION AND MONITORING The WTP is totally automated and is controlled by redundant programmable logic controllers (PLCs). This includes all filter backwashing initiation and sequences, RO flow control, IX polisher regeneration initiation and sequence, and waste neutralization. The O&M Company s personnel are on-site approximately 15 hours per week. The WTP can be operated unattended via a SCADA system which links all system sensors to a central control station within the water treatment plant building. This control terminal can be accessed remotely via a secure VPN (virtually private network) by modem. Through this connection, the O&M Company s staff has access to view and control the plant from their off-site office location, which is located a few minutes away. In the event of any alarm condition, the alarm is displayed at the central control system which also initiates a phone call to alert the O&M Company s on-call service engineers. The service engineer, once alerted, can access the plant control system via laptop from any modem connection and confirm the alarm condition, review any related process trends, take remote action (start or stop units, open or close valves), and do a site inspection via three web cams (with zoom and pan capability) located in the water treatment building. In the event that the condition requires on site presence, a technician can be on site within 1-2 hours. The O&M Company does an on site walk around 4-5 days per week and performs scheduled instrument calibration, and preventative maintenance tasks (e.g. cleaning of RO membranes). OPERATING EXPERIENCE Since the WTP was commissioned in October 2001, it has continuously supplied the normal water requirements of the nuclear power plant without the need for supplemental demineralized water from other sources. During the first few months of operation, the WTP experienced some teething pains. For example, the TOC levels in the product water were slightly above the 10 ppb criteria. This problem was found to be related to incomplete sealing of the RO membranes. Once this was corrected, the membrane performance improved and the TOC has remained consistently below the specified criteria. Also, during the first few months of operation, the WTP required frequent operator attention to address various system alarms. The frequent alarms were addressed by progressively tuning the automation system until the occurrence of the alarms became rare. The system then became fully automated, requiring minimal operator attention, as originally intended. During the first year of operation of the WTP, it was found that the feed water turbidity excursions, along with the presence of silt and sand were considerably higher, more frequent, and prolonged than was originally anticipated. For the most part, the Micro Media filters responded well in terms of their ability to produce a high quality filtrate despite turbidities exceeding 100 NTU on a number of occasions. However, this resulted in more frequent backwashing of the Micro Media filters, with a resultant decline in net flow capacity. This situation was corrected by modifying the filter operating sequence to introduce a very short flow reversal, rather than a complete backwash. This increased the run length between backwashes by more than 500% with the improved net capacity despite turbidity upsets. Subsequent investigation into the mechanism of this flow reversal (subsequently named backslip ), and its refinement has led to a patent application for the process by the Equipment supplier. Both the O&M Company and OPG s personnel have monitored the performance of the reverse osmosis system closely. At the time of writing this paper, nearly four years since the plant start-up, two of the three RO membrane skids are still operating with the original membrane elements in place. After the first two years of service, the normalized flow through the membranes had declined to an unacceptable level and in-situ cleaning was ineffective in restoring the permeate flux. It was decided to remove the membranes and send them off-site for cleaning. The external cleaning was successful in cleaning the membranes and removing the microbiological
7 fouling material that had caused the permeate flux decline. In order to keep the WTP in operation during the external cleaning, one set of new membranes was purchased and installed on one of the three skids. Then as the membranes for one skid were cleaned, they replaced the membranes from the next skid to be sent for external cleaning. At the end of the cleaning process, two skids contained virtually all cleaned membranes, one skid contained virtually all new membranes, and a set of cleaned membranes were set aside for future potential replacement. At the time of writing, after almost four years of operation, no further membrane replacements have been required. In-situ cleaning of the membranes is required primarily to control microbiological growth, which is particularly acute during summer months when the feed water temperature exceeds o C. Water quality data is continuously recorded and the average values for the key chemistry parameters are summarized below in Table II. The WTP comfortably and consistently meets all of the quality criteria. Despite brief excursions in quality, usually due to slight increases in the influent TOC levels, the WTP still meets the upper acceptance criteria for the station (viz. 50 ppb for TOC). Table II: Overall Averages Item Avg. Value Quality Criteria Flow (l/s) design flow rate Resistivity (megohm-cm) 18.0 > 16.7 Sodium (ppb) 0.05 < 0.2 Silica as SiO 2 (ppb) 0.36 < 2.0 Total Organic Carbon (ppb) 5.1 < 10.0 % of Volume Meeting Specified Quality * 97.8 N/A Water quality criteria was also established for total sulphates and total chlorides, although it was recognized that these parameters could not be readily monitored on-line at the low levels specified (< 1.8 ppb for total sulphates, and < 0.8 ppb for total chlorides). It was assumed that if the conductivity met the specification that the total sulphate and total chloride levels would also be within the specification. * Note: For the remainder of volume (2.2%) water did not meet highest quality for which contractor is paid for water, but met acceptable quality standard for acceptance by OPG. This assumption was to be tested and confirmed periodically by carrying out sulphate and chloride testing programs using sensitive instrumentation (on-line ion chromatography), the results of which are summarized in Table III. The results indicate that the total sulphate and total chloride levels indeed meet the quality criteria. The low value of total chloride is an indication that minimal amounts of trihalomethanes are passing through the WTP. Table III: Total Sulphate and Total Chloride Test Results for 2004 Item 2001 Value 2004 Value Quality Criteria Total Organic Carbon (ppb) 8-9 <10 < 10 Total Organically Not Bound <1 <1 specified Heteroatoms (ppb) Total Chloride ** (ppb) <1 <0.3 < 0.8 Chloride (ppb) <0.5 <0.1 Total Sulphate *** (ppb) Not specified < <0.5 < 1.8 Sulphate (ppb) <0.05 <0.05 Not specified By contrast, the old WTP at the PNGS, which consisted of conventional technology (i.e. clarifier, sand filter, carbon filter and conventional ion exchange), produced demineralized water having a TOC of about 200 ppb, with significant associated organically bound sulphate and chloride. The improved TOC values produced by the new WTP are attributable to the use of RO membranes to minimize the passing of TOCs from the feed, and the use of the short bed ion exchange polishers which minimize resin volume and resulting throw of organic impurities from the resin that is encountered in conventional deep bed systems. In 2003, it was determined that the operating costs of the plant could be reduced by an alternate chemical pretreatment scheme. The original design used acid to reduce the RO feedwater ph to prevent calcium carbonate scale formation on the membranes. This results in the conversion of carbonate to bi-carbonate and carbon dioxide, which passes through the RO membranes and is removed ** Total Chloride = Ionic Chloride + organically bound chlorine as chloride *** Total Sulphate = Ionic Sulphate + organically bound sulphur as sulphate
8 by the anion exchange polishers. However, this requires the consumption of caustic soda by the polishers for their regeneration. It was decided to use an anti-scalant chemical to pretreat the RO feedwater at the more neutral ph of This would reduce carbon dioxide formation, polisher loading, and resultant caustic consumption. While this approach initially proved successful, after a few months, it was determined that the performance of the RO membranes had declined significantly, and that in-situ chemical cleaning was unable to successfully restore performance. Upon investigation of various operational parameters, it was determined that the decline in RO system performance coincided with the introduction of the anti-scalant dosing. Upon restoring the pretreatment to the original design (i.e. ph adjust only), RO system performance returned to previous levels, and membrane cleaning was reduced to the original frequency. The root cause of the RO membrane fouling with the anti-scalant based pretreatment could not be identified, but it was suspected that microbiological fouling played a significant role. SUMMARY As expected, some teething pains were experienced during the first year of WTP operation. OPG and the O&M Team s staff worked closely together during this period to identify and overcome these problems. Operation and maintenance of the WTP has now become routine and requires less involvement from OPG s personnel on a day-to-day basis. The following is a brief summary of some of the positive experiences and lessons learned from this project. POSITIVE EXPERIENCES - WTP produces excellent product water quality; exceeds the demineralized water quality specification for the key parameters by a fairly wide margin Short implementation time 8 months from contract signing to delivery of first volumes of demineralized water (includes building construction, system design and manufacture, installation, and commissioning) Cost to produce water is fixed for 10 year contract term Highly automated plant can be operated remotely; staffed by one full-time operations coordinator The O&M Company s office is close by; additional support staff are just minutes away WTP building and equipment, as well as provision for back-up emergency water treatment trailers. In this case, the WTP building is surrounded on all sides (i.e. by water, roadways, buildings, and equipment). REFERENCES 1. R. Al-Samadi, Technical Memorandum, Proposed PNGS WTP Siting, September 21, OPG Specification No.: P-TS , Technical Specification for Outsource Water Treatment Plant, Rev. 1 Section 2B5, DCP No. 395, March 5, PNGS B Safety Report, Volume I Plant Description, 1997 Edition, Table Proposal from Prime Contractor for PNGS WTP, Section , January 15, Mike Sheedy, Eco-Tec Inc., Peter G. Kutzora, WE Energies. The Use of Short Bed Ion Exchange Technology for the Production of High Purity Water at WE Energies Pleasant Prairie Power Plant. Technical Paper presented at International Water Conference Ed Ritchotte, Commonwealth Electric Co., Wayne Rezendes, Canal Electric Co., Bradley Smith, Tod Wilson, Eco-Tec Inc. Water Treatment System Retrofit at Canal Electric Power Station. Technical Paper Presented at PowerGen 98 conference in Orlando Florida, December Doug Jackson, Bryce Heartwell, TransAlta Energy Corp., Michael Dejak, Cathy Fletcher, Eco-Tec Inc., Short Bed Demineralizer Technology at TransAlta Energy. Technical Paper Presented at International Water Conference, Pittsburgh, October LESSONS LEARNED - If possible, the WTP location should be selected to allow sufficient space to accommodate the
performance of the ultrapure make-up system at Turkey Point Nuclear Power Plant
Water Technologies & Solutions technical paper performance of the ultrapure make-up system at Turkey Point Nuclear Power Plant Authors: Stephen P. Ellis, Laboratory Manager, Ionics and Richard Steinke,
More informationSHORT BED ION EXCHANGE TECHNOLOGY PRODUCES ULTRAPURE WATER WITHOUT USING A MIXED BED
SHORT BED ION EXCHANGE TECHNOLOGY PRODUCES ULTRAPURE WATER WITHOUT USING A MIXED BED Michael Sheedy Eco-Tec Inc., 1145 Squires Beach Road, Pickering, Ontario, Canada, L1W 3T9. Presented at the EPRI 8 th
More informationKEYWORDS: Ion exchange, compressed short bed, wastewater, filter, secondary water, tertiary water, reverse osmosis (RO), electrodeionization (EDI).
Increased Water Treatment Plant Capacity at a Mexican Power Station Using Micro Media Filters Ahead of RO and Replacing EDI with Ion Exchange RUSI KAPADIA, MICHAEL SHEEDY, DONALD SWAINE, Eco-Tec Inc.,
More informationUse of Spiral Wound UF in RO Pretreatment
Use of Spiral Wound UF in RO Pretreatment Authors: Harry Dalaly, Asia Pacific Sales Manager, Hydranautics and Yeoh Cheik How, Facilities Senior Engineer, Hewlett-Packard Singapore The Hewlett-Packard Singapore
More informationSIX YEARS OF SHORT-BED DEMINERALIZATION AT THE ONTARIO HEALTH SCIENCES CENTRE
SIX YEARS OF SHORT-BED DEMINERALIZATION AT THE ONTARIO HEALTH SCIENCES CENTRE JACQUES BERNIER, TransAlta Energy Ltd., Ottawa, Ontario JAMES HODD, BRADLEY SMITH, AND TOD WILSON, Eco-Tec Inc., Pickering,
More informationusing EDI to meet the needs of pure water production
Water Technologies & Solutions technical paper using EDI to meet the needs of pure water production Authors: Ted Prato and Christopher Gallagher, Ionics This paper was originally presented at the 61st
More informationWater supplied by Marafiq does not meet the process requirements.
WATER TREATMENT In Industries Water is used for: a. Drinking b. Cleaning c. Cooling d. Producing Steam e. Process requirement Why we need to treat water? For human consumption a. Water to be purified (Make
More informationHigh Purity Boiler Water Production Using Municipal Waste - water at a Combined Cycle Gas-Fired Generating Station
High Purity Boiler Water Production Using Municipal Waste - water at a Combined Cycle Gas-Fired Generating Station Michael Sheedy and George Di Falco ABSTRACT The recovery of wastewater for industrial
More informationREQUEST FOR PROPOSALS DESAL ANTISCALANT/CLEAN-IN-PLACE CHEMICALS BID NO: ADDENDUM 1
REQUEST FOR PROPOSALS DESAL ANTISCALANT/CLEAN-IN-PLACE CHEMICALS BID NO: 18-18006 ADDENDUM 1 BIDS DUE: April 30, 2018 @ 3:00 PM Central Time To report suspected ethics violations impacting the San Antonio
More informationLenntech. Using EDI to Meet the Needs of Pure Water Production. EDI Process. Summary. Introduction
Lenntech info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 Using EDI to Meet the Needs of Pure Water Production Authors: Ted Prato and Christopher Gallagher, Ionics This paper
More informationBucking the Industry Trend. Simple Change to Water System Saves New Jersey Manufacturer $23,000 Annually
Simple Change to Water System Saves New Jersey Manufacturer by Kevin Preising Sales Engineer . Summary: Over the past two decades, the trend in the water treatment industry has been towards more and more
More informationNIPPON PAPER RO SYSTEM + 2 Others
NIPPON PAPER RO SYSTEM + 2 Others 1 March 2014 Greg Wyrick District Account Manager John Zora District Account Manager 2 Purpose: Review the design, function, layout, and operation of the RO system. Process:
More informationReclaimed Waste Water for Power Plant Cooling Tower Water & Boiler Feed Make-up. Richard Coniglio, Business Product Manager
Reclaimed Waste Water for Power Plant Cooling Tower Water & Boiler Feed Make-up Richard Coniglio, Business Product Manager 70% Covered with Water 3% is Fresh Water 1% of the Fresh Water is only accessible.
More informationMembrane Technology: From Manufacture to. May Production
Membrane Technology: From Manufacture to May 2018 Production Osmosis Graphic pulled from https://earthobservatory.nasa.gov/features/water/page2.php Water Sources Surface Waters Ground Water Seawater Lakes
More informationPRESENTATION OF CONDENSATE TREATMENT
Via Pietro Nenni, 15-27058 VOGHERA ITALY Tel. +39 0383 3371 Fax +39 0383 369052 E-mail: info@idreco.com PRESENTATION OF CONDENSATE TREATMENT THE CONDENSATE TREATMENT The absence of impurities in feed water
More information5.B Generation of pharmaceutical water Author: Michael Gronwald Co-Author: Dr. Ralph Gomez / Up06
Generation of pharmaceutical water Generation of pharmaceutical water Author: Michael Gronwald Co-Author: Dr. Ralph Gomez / Up06 Here you will find answers to the following questions: What are the different
More informationThe evolution of high purity water production
FEDI Fractional Electrodeionization from EDI to FEDI The evolution of high purity water production EDI THE CONVENTIOL PROCESS Reject Electrodeionization Cell DEIONIZED WATER Reject Electrodeionization
More informationMembrane Protection Resins Ion Exchange Resins and Reverse Osmosis in Partnership
Membrane Protection Resins Ion Exchange Resins and Reverse Osmosis in Partnership By Francis Boodoo The Purolite Company Brian Windsor Purolite International Ltd Classical Ion Exchange in Partnership with
More informationProduced Water Treatment Systems
Produced Water Treatment Systems High performing, low cost filtration and ion exchange softener systems A d v a n c e d R e s o u r c e R e c o v e r y & P u r i f i c a t i o n S o l u t i o n s RecoPur
More informationVOLUME 06 ISSUE 07-JULY 2013
VOLUME 06 ISSUE 07-JULY 2013 Michael Dejak, Eco-Tec Inc., Canada, unveils a next generation water filtration technology for the oil and gas industry. T here is a need in many segments of the oil and gas
More informationDOWEX UPCORE Ion Exchange Resins Retrofit of Demineralizer with UPCORE System Cuts Chemical Costs by 50%
Case History DOWEX UPCORE Ion Exchange Resins Retrofit of Demineralizer with UPCORE System Cuts Chemical Costs by 50% Site Information Location Indiana, USA Purpose Improve short servicecycle run lengths
More informationTreatment of Coal Bed Methane Produced Water Using Short Bed Ion Exchange MICHAEL SHEEDY AND PAUL ROBINSON, Eco-Tec Inc., Pickering, Ontario
Treatment of Coal Bed Methane Produced Water Using Short Bed Ion Exchange MICHAEL SHEEDY AND PAUL ROBINSON, Eco-Tec Inc., Pickering, Ontario IWC-08-XX KEYWORDS: ion exchange, coal bed methane, produced
More informationCartwright Consulting Co.
Cartwright Consulting Co. WWW.CARTWRIGHT-CONSULTING.COM pscartwright@msn.com United States Office European Office 8324 16 th Avenue South President Kennedylaan 94 Minneapolis, MN 55425-1742 2343 GT Oegstgeest
More informationPlease Contact us for a price on this Refurbished Ion Exchange Softener!
Recoflo Softener Recoflo ion exchange technology utilizes fine mesh resin beads, a fully packed resin bed, and counter-current regeneration. These unique features help to improve exchange kinetics, reduce
More informationCartwright Consulting Co.
Cartwright Consulting Co. WWW.CARTWRIGHT-CONSULTING.COM pscartwright@msn.com United States Office European Office 8324 16 th Avenue South President Kennedylaan 94 Minneapolis, MN 55425-1742 2343 GT Oegstgeest
More informationTreatment Technologies
Treatment Technologies Precipitation Softening INTRODUCTION CHEMISTRY OF PRECIPITATION SOFTENING COLD LIME SOFTENING WARM LIME SOFTENING HOT PROCESS SOFTENING SILICA REDUCTION REDUCTION OF OTHER CONTAMINANTS
More informationRECOFLO WATER SOFTENER
PB0103NS RECOFLO WATER SOFTENER Low Cost Softened Water T he Recoflo Softener outperforms other water softening systems with its high product quality and low operating cost. The distinctive design and
More informationULTRAFILTRATION FOR REVERSE OSMOSIS-PRETREATMENT
ULTRAFILTRATION FOR REVERSE OSMOSIS-PRETREATMENT Ajay Popat Chief Executive Officer Ion Exchange Waterleau Ltd. BASIC CONCEPTS OF ULTRAFILTRATION Ultrafiltration Pre-treatment is the best pre-treatment
More informationCooling Tower Blowdown Treatment and Reuse in a Coal Fired Power Plant in India Reducing the water footprint in coal fired power plants
Cooling Tower Blowdown Treatment and Reuse in a Coal Fired Power Plant in India Reducing the water footprint in coal fired power plants Author name Deepak Kachru Company Aquatech Systems (Asia) Pvt. Ltd.
More informationPresented by: Jeff Freitag, The Water Guy Jon Tiegs, General Manager
Presented by: Jeff Freitag, The Water Guy Jon Tiegs, General Manager OBJECTIVES Understand The Importance of Practicing Key Performance Indicators (KPI s) in Your Boiler Room Identify Key Components of
More informationsurface and wastewater desalination by electro dialysis reversal
Water Technologies & Solutions technical paper surface and wastewater desalination by electro dialysis reversal Author: Robert P. Allison Paper presented at the American Water Works Association Membrane
More information0UltraClean. Ion Exchange Resins for Ultra-pure Water in the Electronics and Semiconductor Industry
Ion Exchange Resins for Ultra-pure Water in the Electronics and Semiconductor Industry Lenntech info@lenntech.com www.lenntech.com Tel. +31-15-261.09.00 Fax. +31-15-261.62.89 0UltraClean Introduction Since
More informationProduced Water Treatment Systems
Produced Water Treatment Systems High Performing, Low Cost Filtration and Ion Exchange Softener Systems Advanced Resource Recovery & Purification Solutions Produced Water Treatment Application Extraction
More informationPERFORMANCE AND RESIDUAL MANAGEMENT ASSESSMENT OF 5 MGD MEMBRANE WATER PLANT. Presented by: Stephen P. Dorman, P.E.
PERFORMANCE AND RESIDUAL MANAGEMENT ASSESSMENT OF 5 MGD MEMBRANE WATER PLANT Presented by: Stephen P. Dorman, P.E. sdorman@ksaeng.com 1 Outline Background Assessment of: Clarification Filtration Residuals
More informationNEW TECHNOLOGIES & BREAKTHROUGHS TO OLD DEIONIZATION APPLICATIONS
NEW TECHNOLOGIES & BREAKTHROUGHS TO OLD DEIONIZATION APPLICATIONS By: Jim Wark, jwark@culligantx.net STS AIChE March 2018 Monthly Dinner Meeting Workshop Thursday, March 1, 2018, 5:30pm-6:30pm CST The
More informationKirill Ukhanov, GE Water & Process Technologies, Russia, describes how advanced membrane technology is helping a Russian refinery to meet stringent
Kirill Ukhanov, GE Water & Process Technologies, Russia, describes how advanced membrane technology is helping a Russian refinery to meet stringent wastewater requirements. In Russia, there are strict
More informationSulaibiya world s largest membrane water reuse project
Water Technologies & Solutions technical paper Sulaibiya world s largest membrane water reuse project background In May 2001, a consortium including Mohammed Abdulmohsin Al-Kharafi and Sons (The Kharafi
More informationAgenda. Pretreatment Background Typical Contaminants Practical Examples Methods of Treatment and References
Pretreatment of Seawater for Desalination Plants Richard Dixon, ITT Agenda Pretreatment Background Typical Contaminants Practical Examples Methods of Treatment and References 2 Typical Constituents in
More informationeffective deoxygenation by a hybrid process combining gas transfer membranes with catalytic oxygen reduction
Water Technologies & Solutions technical paper effective deoxygenation by a hybrid process combining gas transfer membranes with catalytic oxygen reduction Authors: S. B. Gorry, SUEZ, W. E. Haas, SUEZ
More informationFEDI. Fractional Electrodeionization. The evolution of high purity water production
FEDI Fractional Electrodeionization from EDI to FEDI The evolution of high purity water production EDI THE CONVENTIONAL PROCESS Reject Electrodeionization Cell DEIONIZED WATER Reject The Electrodeionization
More informationDOW Ultrafiltration. Case History. DOW Ultrafiltration Modules Protect Reverse Osmosis System from High Iron
Case History Modules Protect Reverse Osmosis System from High Iron Site Information Location: ShanXi, China Capacity: 2074 m 3 /h (5283 gpm) Purpose: Pretreat waste water prior to RO system Time in Operation:
More informationDOWEX Ion Exchange Resins
Case History DOWEX Ion Exchange Resins UPCORE System Reduces Boron to Undetectable Levels in Ultrapure Water Site Information Location: Dresden, Germany Purpose: Reduce boron levels to meet ultrapure water
More informationLenntech. Tel Fax
Case History Lenntech info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 Site Information Location: Beijing, China Capacity: Second Phase, 150m 3 /h; Third Phase, 160m 3 /h Time
More informationADVANCED SOFTENING MATERIAL. for problem water. SIMPLE SOLUTION FOR 5 PROBLEMS hardness iron manganese natural organic matter ammonium
ADVANCED SOFTENING MATERIAL for problem water SIMPLE SOLUTION FOR 5 PROBLEMS hardness iron manganese natural organic matter ammonium Used by water treatment companies globally since 1998 AMERICA WHAT ECOMIX
More informationWestern BLRBAC Review/Refresher of Tappi Water Quality Guidelines and Contamination Procedures for mill boilers operating on high purity water
Western BLRBAC Review/Refresher of Tappi Water Quality Guidelines and Contamination Procedures for mill boilers operating on high purity water October 29, 2014 Commitment makes the best chemistry. 1 TAPPI
More informationREACTION TANKS WATER PURIFICATION THROUGH SERVICE DEIONIZATION
REACTION TANKS WATER PURIFICATION THROUGH SERVICE DEIONIZATION SERVICE DEIONIZATION (SDI) Service Deionization (SDI) from Evoqua is a safe and economical way for you to obtain consistent, high-purity water
More informationCooling Tower Blowdown Treatment and Reuse in a Coal Fired Power Plant in India - Reducing the water footprint in coal fired power plants -
Powergen Bangkok 3 rd October 2103 Session 5 Intake, Cooling and Blowdown Treatment Considerations Cooling Tower Blowdown Treatment and Reuse in a Coal Fired Power Plant in India - Reducing the water footprint
More informationEVALUATING NANOFILTRATION, REVERSE OSMOSIS, AND ION EXCHANGE TO MEET CONSUMPTIVE USE CONSTRAINTS AND FINISHED WATER QUALITY GOALS FOR BROWARD COUNTY
EVALUATING NANOFILTRATION, REVERSE OSMOSIS, AND ION EXCHANGE TO MEET CONSUMPTIVE USE CONSTRAINTS AND FINISHED WATER QUALITY GOALS FOR BROWARD COUNTY Frank A. Brinson, P.E., DEE, CDM, Fort Lauderdale, FL
More informationMicro-Media Filtration: An Alternative to Membrane Filtration
Micro-Media Filtration: An Alternative to Membrane Filtration Presented at the 11 th Southwest Chemistry Conference, Park City, Utah August 2002 Craig J. Brown, P.Eng., Eco-Tec Inc., Pickering, Ontario
More informationAD26 Systems for Iron, Manganese, Sulfide and Arsenic Removal
AD26 Systems for Iron, Manganese, Sulfide and Arsenic Removal Technical Bulletin 2004-02 rev0707 Q: What is the AdEdge AD26 System? A: The AD26 system is a pre-engineered, packaged treatment system specifically
More informationThis paper was presented at IEX 96 in Cambridge,UK on July 15 th 1996 and is the copyright of the SCI
This paper was presented at IEX 96 in Cambridge,UK on July 15 th 1996 and is the copyright of the SCI AN ECONOMIC COMPARISON OF REVERSE OSMOSIS AND ION EXCHANGE IN EUROPE P.A.NEWELL, S.P.WRIGLEY, P.SEHN
More informationModule 23 : Tertiary Wastewater Treatment Lecture 39 : Tertiary Wastewater Treatment (Contd.)
1 P age Module 23 : Tertiary Wastewater Treatment Lecture 39 : Tertiary Wastewater Treatment (Contd.) 2 P age 23.3.6 Membrane module A single operational unit into which membranes are engineered for used
More informationMEMBRANE CHEMICALS Presented by: Majid Karami
MEMBRANE CHEMICALS Presented by: Majid Karami Introduction Water shortage is becoming a worldwide problem One of the main solutions to this problem is : Desalination of seawater or brackish water Desalination
More informationADVANCED SOFTENING MATERIAL FOR PROBLEM WATER
ADVANCED SOFTENING MATERIAL FOR PROBLEM WATER SIMPLE SOLUTION FOR 5 PROBLEMS hardness iron manganese natural organic matter ammonium Used by water treatment companies globally since 1998 EUROPE WHAT ECOMIX
More informationREVERSE OSMOSIS INSTALLATION AND OPERATION MANUAL. R12-Wall Mount
REVERSE OSMOSIS INSTALLATION AND OPERATION MANUAL R12-Wall Mount IMPORTANT Please read the entire manual before proceeding with the installation and startup: Do not use where the water is microbiologically
More informationOperation of Hydranautics New ESNA Membrane at St. Lucie West, FL Softening Plant
Ilan Wilf & Scott Rappoport, Operation of Hydranautics New ESNA Membrane at St. Lucie West, FL Softening Plant Introduction St. Lucie West, Florida Service Distrcit employed the first large scale reverse
More informationREVERSE OSMOSIS WATER TREATMENT
REVERSE OSMOSIS WATER TREATMENT LTF 2, LTF 3 and LTF 4 SERIES RO SYSTEMS 14,400 TO 252,000 GALLONS PER DAY AND LARGER Lakeside Water for Affordable Pure Water Technology 1 P age Packaged Reverse Osmosis
More informationCHE-E-2003 Shift Chemist PERSONAL DATA EDUCATION LANGUAGES COMPUTER SKILLS TRAINING COURSES AND CERTIFICATIONS
100405-CHE-E-2003 Shift Chemist Holds a B. Sc. in Chemistry and has about 13 years hands-on experience working as Chemist at Power Plants. PERSONAL DATA Nationality : Egyptian Birth Date : 03/12/1980 Gender
More informationelectrodialysis treatment of surface and waste waters
Water Technologies & Solutions technical paper electrodialysis treatment of surface and waste waters Authors: Robert P. Allison, Senior Process Engineer introduction Electrodialysis (ED) is a membrane
More informationMAKING THE SWITCH FROM LIME TO MEMBRANE SOFTENING: WHEN IS IT THE RIGHT TIME? Introduction
MAKING THE SWITCH FROM LIME TO MEMBRANE SOFTENING: WHEN IS IT THE RIGHT TIME? Joseph R. Elarde CH2M HILL 5801 Pelican Bay Blvd., Suite 505 Naples, FL 34108 joe.elarde@ch2m.com 239-431-9225 Jeff Poteet,
More informationImprovement of Drinking Water Plant Treatment
Improvement of Drinking Water Plant Treatment A. ZOUBOULIS 1, *, G. TRASKAS 1 AND P. SAMARAS 2 1 Department of Chemistry, Division of Chemical Technology Aristotle University, Thessaloniki GR-541 24, Greece
More informationInnovative Groundwater Treatment. Sarah Wilson, Anna Comerton and Elia Edwards OWWA/OMWA Joint Annual Conference London, ON; May 4-7, 2014
Innovative Groundwater Treatment Sarah Wilson, Anna Comerton and Elia Edwards OWWA/OMWA Joint Annual Conference London, ON; May 4-7, 2014 Typical Groundwater Quality Chemical composition of GW influenced
More information--... _ 2-- I I J: 3 4 /
2--- --... _ 3 I I J: 4 / Sea Water Composition Typical Sea Water Values Cations mg/l Na + 10,732 Mg ++ 1,297 Ca ++ 417 K + 382 Anions mg/l Cl 19,337 SO 4 2 2,705 HCO 3 120 Br 66 Total Dissolved Solids
More informationBy: Curt Roth Vice President, Engineering EconoPure Water Systems, LLC. Desalination Pre Treatment with LFNano. An EconoPure White Paper
An EconoPure White Paper 2024 N. Broadway Santa Ana, CA 92706 USA 1+(714) 258 8559 www.econopure.com Desalination Pre Treatment with LFNano By: Curt Roth Vice President, Engineering EconoPure Water Systems,
More informationSome Standard Membranes: Filmtec Membrane, Hydronatics Membrane, Torry membrane and Koch Membrane.
REVERSE OSMOSIS (RO) water treatment process involves water being forced under pressure ( Osmatic Pressure ) through a semipermeable membrane. Temporary and permanent hardness, Total Dissolved Soilds (TDS),
More informationHow A Vertical Tube Falling Film Evaporator Can Be Used to Deliver the Lowest Total Life Cycle Cost for Alberta Produced Water Treatment
How A Vertical Tube Falling Film Evaporator Can Be Used to Deliver the Lowest Total Life Cycle Cost for Alberta Produced Water Treatment Overview Minimizing Installation Costs Evaporator Pilot Program
More informationutilization of chemical treatments to maintain and restore membrane performance
Water Technologies & Solutions technical paper utilization of chemical treatments to maintain and restore membrane performance Author: James P. McIntyre, SUEZ abstract A reverse osmosis unit's reliability
More informationTHE CURRENT USE OF HOLLOW FIBRE ULTRAFILTRATION AS PRE-TREATMENT FOR REVERSE OSMOSIS
THE CURRENT USE OF HOLLOW FIBRE ULTRAFILTRATION AS PRE-TREATMENT FOR REVERSE OSMOSIS Membrane Processes Lower Pressure Membrane Processes Microfiltration (UF) Ultrafiltration (MF) Higher Pressure Membrane
More information1. The Antiscalant, and/or CIP chemicals where specified, provided under this contract shall meet the following specifications:
TO BE OPENED: 11:00 A.M. MST, March 15, 2019 Page 7 R1 of 34 The SUPPLIER shall have prior experience using NSF-Approved chemicals in a municipal water treatment facility with a treatment capacity greater
More informationValve Nest Filter with Time Clock Control Installation and Operation Manual
Valve Nest Filter with Time Clock Control Installation and Operation Manual Effective 5/24/12 Effective 5/24/12 Table of Contents Operating Data. 1 Pre-Installation Data... 2 Filter Parameters Installation
More informationBoiler Water Chemistry: Getting From the Source to the Boiler Colleen M. Layman, PE
Boiler Water Chemistry: Getting From the Source to the Boiler Colleen M. Layman, PE colleen.layman@hdrinc.com 2017 HDR, Inc., all rights reserved. Goals Minimize Scaling Limit Deposition Prevent Corrosion
More informationPOREX Tubular Membrane Filter (TMF ) Applied in a ZLD System as Critical Solid/Liquid Separation Process
POREX Tubular Membrane Filter (TMF ) Applied in a ZLD System as Critical Solid/Liquid Separation Process Abstract Introduction Beijing Shougang Biomass Energy Technology Co., Ltd, a branch company of SHOUGANG
More information27 th ANNUAL WATEREUSE SYMPOSIUM CHALLENGES OF HIGH-SULFATE WASTEWATER RECYCLE. Abstract. Introduction
27 th ANNUAL WATEREUSE SYMPOSIUM CHALLENGES OF HIGH-SULFATE WASTEWATER RECYCLE William Matheson, Duraflow, Tewksbury, MA Abstract A cement products manufacturer, having a sulfate and total dissolved solid
More informationStandard Water Treatment Equipment Solutions WATER TECHNOLOGIES
Standard Water Treatment Equipment Solutions WATER TECHNOLOGIES Innovative Standard Product Line Veolia Water Technologies, a leading provider of integrated water solutions for industrial and commercial
More informationCity of Woodbury. Red Bank Water Treatment Plant - Treatment Alternatives Analysis November 2016
City of Woodbury Red Bank Water Treatment Plant - Treatment Alternatives Analysis November 2016 Background Remington & Vernick was authorized to study and design a treatment process for removal of PFC
More informationZero Liquid Discharge Project Extends Potable Water Supplies
http://dx.doi.org/10.5991/opf.2014.40.0078 Ryan R. Popko, PE, and Phillip J. Locke, PE, are with McKim & Creed (www.mckimcreed.com), Clearwater, Fla. Fred J. Greiner is with the city of Palm Coast, Fla.
More informationCondensate Management Monitoring Condensate
Condensate Management Monitoring Condensate Virginia Durham May 2008 Weyerhaeuser_October 2007-1 Outline Goals in condensate management Monitoring Purpose Sampling Testing Major Streams Contaminants Automatic
More informationU. S. Army Corps of Engineers Liquid Phase Carbon Adsorption Checklist
U. S. Army Corps of Engineers Liquid Phase Carbon Adsorption Checklist Installation Name Site Name / I.D. Evaluation Team Site Visit Date This checklist is designed to facilitate the performance evaluation
More informationAL-KAWTHER INDUSTRIES LTD
AL-KAWTHER INDUSTRIES LTD 1 Presentation On Recycle Of Industrial Wastewater With Media Filtration And Reverse Osmosis By Al- Kawther Industries Ltd. March 2004 2 INTRODUCTION 3 EFFLUENT DISCHARGE STANDARDS
More informationPRESENTATION OF DESALINATION VIA REVERSE OSMOSIS
Via Pietro Nenni, 15-27058 VOGHERA ITALY Tel. +39 0383 3371 Fax +39 0383 369052 E-mail: info@idreco.com PRESENTATION OF DESALINATION VIA REVERSE OSMOSIS Reverse osmosis is the finest level of filtration
More informationZero Blowdown Technology - ZBT Arizona Transportation Center
Zero Blowdown Technology - ZBT Arizona Transportation Center A major transportation center in Arizona was designed to be certified by the USGBC LEED green building program to its highest level, Platinum.
More informationIONPURE CONTINUOUS ELECTRODEIONIZATION (CEDI)
REACTION TANKS IONPURE CONTINUOUS ELECTRODEIONIZATION (CEDI) THE WORLD S FIRST CHOICE FOR CEDI TECHNOLOGY WHAT IS CONTINUOUS ELECTRODEIONIZATION (CEDI)? Reject / Concentrate Product / Dilute Reject / Concentrate
More informationOsmoBC Integrated Membrane Systems
OsmoBC Integrated Membrane Systems For Industrial Wastewater Treatment Fluid Technology Solutions, Inc. OsmoF2O FO Membranes HBCR High Brine Concentrator OsmoZLD Treatment Process INTEGRA Disk Filtration
More informationSummary of Issues Strategies Benefits & Costs Key Uncertainties Additional Resources
Summary of Issues Strategies Benefits & Costs Key Uncertainties Additional Resources KEY POINT: Appropriate pre-treatment can prevent fouling and scaling, optimize membrane performance, and extend membrane
More informationFILTRATION INDUSTRY -An Overview
FILTRATION INDUSTRY -An Overview Introduction The term filtration, as applied to water treatment, refers to the removal of suspended solids from water. In most cases it is the last stage in the pre treatment
More informationPRIMARY DRINKING WATER FROM WASTEWATER EFFLUENT: PILOT TEST EXPERIENCE AT THE MIAMI DADE SOUTH DISTRICT WWTP
PRIMARY DRINKING WATER FROM WASTEWATER EFFLUENT: PILOT TEST EXPERIENCE AT THE MIAMI DADE SOUTH DISTRICT WWTP Paul J. Vinci, P.E. 1, Richard Cisterna, P.E. 1, Robert Harris 1, John Chorlog, P.E. 2, Joseph
More informationHetch Hetchy Treatability at the Sunol Valley Water Treatment Plant
Operated by the San Francisco Public Utilities Commission Hetch Hetchy Treatability at the Sunol Valley Water Treatment Plant Annual Technology Transfer Workshop November 13, 2013 Enio Sebastiani, P.E.,
More informationPRODUCTION OF PW/HPW/WFI AND USP/EP REQUIREMENTS. Erez Eilam F&U Area Lead Novartis Singapore Bio production Operations
PRODUCTION OF PW/HPW/WFI AND USP/EP REQUIREMENTS Erez Eilam F&U Area Lead Novartis Singapore Bio production Operations Agenda Background USP/EP Standard Steps in production Available technologies Key aspects
More informationNPDES COMPLIANCE OF COOLING TOWERS BLOWDOWN AT POWER PLANTS WITH RECLAIMED WATER AS SOURCE WATER
NPDES COMPLIANCE OF COOLING TOWERS BLOWDOWN AT POWER PLANTS WITH RECLAIMED WATER AS SOURCE WATER Nathan Schmaus, P.E. *, Joseph Viciere, P.E., BCEE, CDM Smith CDM Smith, 1715 North Westshore Boulevard,
More informationWater Treatment Plant Year-end Report for 2014
Water Treatment Plant Year-end Report for 2014 Water demand The total influent volume of water drawn from the Assiniboine River for treatment was approximately 6.03 % higher in 2014 than in 2013. 2013
More informationProducing High-Purity Recycled Water for Industrial Applications with Microfiltration and Reverse Osmosis: Lessons Learned
Producing High-Purity Recycled Water for Industrial Applications with Microfiltration and Reverse Osmosis: Lessons Learned ABSTRACT Mallika Ramanathan*, Alicia Cohn*, John Hake*, Ken Abraham**, Srinivas
More informationReady, Set, and Go: Deer Valley WTP East Basins Performance Testing, Start-Up, and Commissioning Toby Teegerstrom Brian Watson
Ready, Set, and Go: Deer Valley WTP East Basins Performance Testing, Start-Up, and Commissioning Toby Teegerstrom Brian Watson January 25, 2011 Presentation Outline Background Process Overview Start-Up
More information1. Inspection and monitoring... 3
1 Index 1. Inspection and monitoring... 3 1.1 Handling of new elements... 3 1.1.1 Storage of original packaged RO elements... 3 1.1.2 Packing... 3 1.2 Initial start- up checks of a plant... 3 1.2.1 Preparation
More informationExtreme Recovery Membrane Process and Zero Liquid Discharge Low Temperature Crystallization for Treating Scaling Mine Waters
Extreme Recovery Membrane Process and Zero Liquid Discharge Low Temperature Crystallization for Treating Scaling Mine Waters Malcolm Man, Xiangchun Yin, Zhongyuan Zhou, Ben Sparrow, Susie Lee, Mitch Frank
More informationNadeem Shakir Qatar Petroleum. The 2nd Joint Qatar Japan Environmental Symposium, QP JCCP The 21st Joint GCC Japan Environmental Symposium
Nadeem Shakir Qatar Petroleum Scheme of Presentation General Overview of QP Refinery, Mesaieed. Challenges in Treatment Existing Waste Water Treatment Facilities Capacity Expansion and Upgradation of WWTP
More information1. Scaling. H.O.: H-5/21, KRISHNA NAGAR, DELHI Tel.: , Fax:
Boiler Water Problems and Its Causes Water is the essential medium for steam generation. Conditioning it properly can increase the efficiency of boiler and as well as extend the boiler s life. Treating
More informationProducing ultra-pure water. electro-deionization
Producing ultra-pure water by electro-deionization What is electro-deionization (EDI)? Electro-deionization (EDI) combines two well established water treatment methods - electrodialysis and ion exchange
More informationZero Discharge for Textile Industry
Zero Discharge for Textile Industry C K Sandeep, General Manager Corporate Marketing, Ion Exchange (India) Ltd. Introduction The post liberalization period has led to the rapid growth of industrial output
More informationTotal Water Management in Thermal Power Station By Mr. N. Ramachandran - Associate Vice President (Technology)
Total Water Management in Thermal Power Station By Mr. N. Ramachandran - Associate Vice President (Technology) Introduction Large volumes of water are required by thermal power stations for various applications
More informationIWC-10-XX. KEYWORDS: Produced water, ion exchange, nutshell filter
Produced Water Recovery at Seneca Resources Using Short Bed Ion Exchange LEWIS KRAUSE, MICHAEL SHEEDY, Eco-Tec Inc. Pickering, Ontario and KEITH JONES, Seneca Resources, Bakersfield, California. IWC-10-XX
More information