1 THE USE OF THERMOGRAPHY TO AID DESIGN OF REFRIGERATED ROAD VEHICLES S. ESTRADA-FLORES and A. EDDY Supply Chain Innovation, Fax: ; S. Food Science Australia PO Box 52, North Ryde, NSW 1670, Australia. ABSTRACT A thermographic survey was performed on two types of insulated bodies: (a) truck bodies, holding an internal temperature of 28 o C at an ambient temperature of 38 o C; and (b) insulated panel vans, holding an internal temperature of 2 o C at an external ambient temperature of 30 o C. Relevant results related to the design of the vehicles include evidence of heat leakage through the seals of the back and side doors. Hardening of the seals due to aging and sudden internal temperature changes are likely explanations for the former, whereas thermal expansion is the reason for the gaps in the side door seals. Heat leakages through the pockets of the side lights, where the insulation is usually at least 12 mm thinner than in the rest of the body, were evident. Thermal bridges due to the presence of structural ribs in the roof and sides of trucks were also observed. 1. INTRODUCTION During the past three years, the authors have assessed a variety of insulated bodies used for cold chain logistics, following the methodology described in the Australian Standard (Standards Australia, 2003). A key test in this standard is the insulation efficiency (heat leakage) test by the inner heating method. This test determines the effectiveness of the insulated body, measured as a K value, by means of creating a temperature differential of no less than 20 o C between the cargo space and the external environment. The K value obtained reflects the properties of the insulation and the manufacturing process of the body. For example, if a particular truck body encompasses a layer of high-quality insulation, but the manufacturing process and/or design of the body allows for significant thermal bridging, both factors will affect the resulting K value. The heat leakage test does not provide information on the location of the defects which contribute to a high K value. Therefore, the authors have used thermographic surveys to determine the likely reasons for failure of some designs to achieve adequate insulation effectiveness. Thermography is a two-dimensional, non-contact technique that allows fast surface temperature mapping of objects subjected to a large temperature difference from their surroundings (Meola et al., 2004). Given certain assumptions in terms of the radiative heat transfer, the radiation captured by a thermographic camera can be interpreted as surface temperatures. The temperature values can then be displayed as either greyscale or pseudocoloured images. The radiation detected is in the infrared spectrum, usually in the 2 to 5.6 µm and 8 to 14 µm regions (Avdelidis and Moropoulou, 2003). By taking snapshots of several parts of the insulated truck body, the exact location of problematic features in truck bodies that present high K values can be ascertained and solutions for these can be implemented. This paper summarizes the findings of qualitative surveys undertaken in two types of insulated bodies: (a) 45-ft trailer bodies, holding an internal temperature of 28 o C at an ambient temperature of 38 o C; and (b) insulated panel vans, holding an internal temperature of 2 o C at an external ambient temperature of 30 o C. The most common heat leakages found in these surveys relate to general design features of refrigerated road vehicles, which are also discussed in this paper.

2 2. METHODOLOGY The effectiveness of the insulated body of the two trucks and three of the panel vans, measured as a K value, was determined previous to the thermographic survey. The methodology and procedure followed is outlined in the Australian Standard (Standards Australia, 2003) and also described by Estrada-Flores and Tanner (2005). The thermographic survey was carried out by means of a thermographic camera (ISI 525 Snapshot Thermal Camera, range 0 to 350 o C, accuracy 2% reading). The spectral band covered by the camera used was 8 µm to 12 µm, with a thermal resolution of 0.1 o C at 30 o C. In all the surveys undertaken, the camera was mounted on a tripod, about 1.5 m from the floor and between 1.5 and 2.5 m away from the surface photographed. Visible light photographs were taken with a digital camera at the same angle and at a similar field of view, for later analysis Truck bodies tested K value tests and thermographic surveys were carried out in Food Science Australia s controlledenvironment shipping-container test facility. The ambient temperature was 38 o C and the refrigeration set-point of both trucks was set to 28 o C. No solar radiation (either direct or indirect) was incident on the external surface of the trucks during the thermographic survey. The total survey time was about 1 hour. The truck bodies were both manufactured with composite (sandwich panel type) walls. The external and internal layers were made of fibreglass and foamed polyurethane was used for the middle layer. The K values and other characteristics of the trucks tested are presented in Table 1. Table 1. Description of trucks tested. TRUCK INTERNAL DIMENSIONS 1 Length = m Width = 2.42 m Height = 2.68 m 2 Length = m Width = 2.41 m Height = 2.76 m INSULATION THICKNESS (m) Roof and ceiling: 0.13 Sidewalls: 0.08 Front wall: 0.10 Rear doors: 0.07 Roof and ceiling: 0.13 Sidewalls: 0.04 Front wall: 0.10 Rear doors: 0.07 K value (W m -2 K -1 ) REFRIGERATION PLANT AGE 0.35 Carrier Ultima XTC 2 months 0.54 Carrier Ultima XTC 1 month 2.2. Panel vans tested K value tests were carried out in Food Science Australia s controlled-environment shipping-container test facility. Thermographic surveys were carried out inside a loading facility in Granville, NSW. The facility was insulated but the temperature of the loading dock was not controlled. The ambient temperature around the vans tested was about 30 o C and the refrigeration set-points were set to 2 o C. there was no direct solar radiation on the external surface of the vans during the thermographic survey. The surveys were completed in about 3 hours. The K values and other characteristics of the vans tested are presented in Table 2. The values observed were higher than those calculated for the trucks; the panel vans had been in use for more than one year when they were tested. The exact age of each insulated body was unknown, as these vans were converted to refrigerated vehicles before the present owner purchased them.

3 Table 2. Description of panel vans tested. VAN INTERNAL DIMENSIONS (Length x width x height, m) K value (W m -2 K -1 ) REFRIGERATION PLANT x 1.74 x Transicold OED6 (3.5 kw x 1.55 x Transicold OED6 (3.5 kw x 1.74 x Transicold OED6 (3.5 kw x 1.74 x Transicold OED6 (3.5 kw x 1.74 x 1.86 m 1.11 Transicold OED6 (3.5 kw AGE 3. RESULTS AND DISCUSSION During the thermographic inspections, some practical guidelines were established: (a) The difference in emissivity of surface coatings (e.g. paint, rust or highly reflective plastic light casings) may cause difficulties during the interpretation of the thermograms. A change in emissivity from one surface to another is difficult to distinguish from a true temperature change. In some cases, a highly polished surface may be interpreted as a thermal bridge, creating a false positive. An understanding of the design features and a temperature check with a second measuring device (e.g. a thermocouple or thermometer) can help to distinguish these false positives from actual temperature differences. (b) In view of (a), the thermographic survey gives more accurate results in dark conditions (e.g. the lights in the testing facility are off). (c) The thermographic image captured with the camera changed considerably, depending on the viewing angle relative to the vehicle s surface. When the surface is viewed at right angles, the changes in surface temperature appeared to be scaled differently to the changes detected at glancing angles However, sources of heat leakages could still be observed qualitatively and identified at different angles. (d) The refrigeration units diesel engines and condensers produce waste heat, some of which warms nearby surfaces being measured. Care needs to be taken to ensure that these sources are not mistaken for a thermal bridge, particularly when the joint between the refrigeration plant and the insulated body is being assessed. Tables 3 and 4 present the most significant heat leakages observed during the thermographic surveys of truck 1 and truck 2, respectively. The tables also present an explanation of the photographs and the relevant design features of the insulated body that influence the particular thermal behaviour described in the thermograms. The temperature scale is shown in the right hand side of each thermographic image. In general, red and yellow areas represent the warmest zones of the body, whereas blue and purple areas represent cold zones (i.e. zones that present heat leakages).

4 Table 3. Representative results obtained during the thermographic survey of Truck 1 Structural component Thermographic image The plates behind the latches, detected as blue (cold) zones, secure the latch against the door. Steel creates a significant thermal bridge. Elements such as hinges, corners and brackets can introduce a significant heat conduction load towards the internal Emergency door release load space. Bottom front corner of side door Underneath plant refrigerating Left hand side (upper corner) rear door Heat leakages through the seals of the side door. Rippling the external skin of the door indicated that thermal expansion of the external layer of fibreglass had occurred, thus distorting the door. This was a likely explanation for the gaps observed between the door seals and the body. A cold zone across the width of the back of the vehicle was detected at floor level, suggesting that the edge of the T-section metallic floor, or the bonded joint between the floor and the wall, was a source of heat leakage. Heat leakages through the seals of the rear door were observed. This effect is often observed in used trucks, due to deterioration and hardening of the seal. However, this source of heat leakage can also occur in trucks with new seals, due to the pressure difference between the internal (cargo) space and the external environment. Structural pockets to fit lights and handles usually decrease the thickness of the insulation by 12 to 15 mm. Side light

5 Table 4. Representative results obtained during the thermographic survey of Truck 2 Structural component Joint between left hand side wall (as seen from the refrigeration unit side) and roof Left hand side wall Thermographic image The manufacturing of refrigerated vehicles usually encompasses three types of joints: mechanical fastened, welded and adhesively bonded. The first category involves drilling the two parts and then coupling with bolts or rivets. This seems to be the technique used in this joint, leading to heat leakages due to drilling, use of highly conductive materials, and/or poor adhesion between the insulation layers. Good manufacturing practices for joints include sealing the gaps left between insulation layers with foamed polyurethane. Insulated bodies require a rigid structure with posts, beams or internal reinforcement. These structural features can act as a source of heat leakage, even if the posts and beams are foamed with insulation. The vertical blue lines indicate the existence of internal webs of fibreglass reinforcement, confirmed with a carpenter s electronic stud-finder. In other designs, this could be due to vertical discontinuities in the foaming process, due to the use of sectional foamed panels that have not been fitted correctly. Detail of the back door latch and seal Similarly to truck 1, heat leakages through the seals of the rear door were observed. The same explanation applies in this case. Figure 1 presents two examples of the thermographic surveys undertaken for the five vans. The heat leakages detected in the body of the van seem to be related to the foaming-in-place insulation technique used to convert the vans to refrigerated vehicles. In this technique, the insulation (usually polyurethane) is foamed to fill the space between a wooden frame and the metallic structure of the cargo space. Wet-laid insulation is not very efficient at preventing heat entering the cargo space, because the metal ribs in the side walls act as thermal bridges. The effect of these heat leakages can be observed in Fig. 1(a), where the average temperature difference between the warmest and coldest areas of the external surface of the van was 16 o C. In Fig. 1(b), the heat leakage through the seals of the rear doors was evident; the average temperature difference between the warmest and coldest areas in the rear doors was 15 o C.

6 (a) (b) Figure 1. (a) Side view of Model 2; and (b) rear doors of Model 5. The thermographic images show 12 sections of each visible light image. In summary, examples of design and manufacturing aspects that decrease the insulation effectiveness of refrigerated road vehicles observed in these surveys include: (a) Structural pockets to fit lights and handles usually decrease the thickness of the insulation by 12 to 15 mm in those areas. (b) Metallic latches, structural ribs, hinges, rivets or screws often impinge on the insulation layer. (c) Pockets of air may be incorporated in the insulation a s it is foamed in place.

7 (d) Poor bonding of materials and sub-optimal distribution of insulation thickness between the horizontal walls (roof and floor) and sidewalls can create air gaps, which also decrease the insulative efficiency of the body. (e) Door gaskets may be poor insulators when manufactured and heat infiltration may increase as the gaskets deteriorate with time. Pressure differences between external and internal environments can also lead to an increase in air infiltration through door seals. (f) In the long term, accelerated aging of the insulation may occur if moisture migrates to the insulation layer; this can occur if there are gaps in the seams or rivet holes. A strategy frequently recommended for reducing the sources of heat leakages observed in this study is to increase the overall insulation thickness. However, this strategy needs to be analyzed in the context of current demands in the logistics industry: A strong market-driven influence on the design of insulated trailer bodies is the maximizing of revenue per shipment by means of maximizing the cargo space available per unit. A stow using Australian standard pallets (1.17 m x 1.17 m) requires 2.34 m clear internal width, which is suitable for dry goods (i.e. uninsulated trucks). A stow using ISO standard pallets (1.00 m x 1.2 m) requires 2.2 m clear internal width, thus allowing a design with thicker insulation; however, few logistics companies in Australia use ISO pallets because the manufacturing industry sizes packaging for the Australian standard pallet. Government regulations establish fixed external dimensions for trailer bodies, therefore, the insulation thickness is compromised. These drivers result in a push towards thinner wall insulation in refrigerated road vehicles. Thin, inefficient insulation has a negative impact in the profitability of logistics operations (i.e. more cooling power is required to avoid unsafe temperatures during transport of perishables) and in the environment (i.e. the increase in cooling power leads to the use of more diesel, thus increasing harmful exhaust emissions and noise pollution). New insulating materials, such as vacuum panels, could fulfill the requirements of decreasing the thickness of the wall and simultaneously decreasing the energy usage of refrigerated vehicles. The reduction of thermal bridges by improving the current design of refrigerated vehicles is also an alternative to reduce heat leakages. For example, materials which are poor thermal conductors can be used to break the thermal bridges caused by aluminum or steel structural reinforcement, by inhibiting direct contact between the external (ambient) environment and the cargo space. 4. CONCLUSIONS Current thermal performance standards for refrigerated road vehicles provide a means to assess the quality of the insulated body against a benchmark value, thus allowing comparisons between insulated bodies of various sizes and manufacturing processes. However, they do not provide information on the location of defects that negatively affect the effectiveness of insulation. Thermographic imaging is a practical tool that enables the qualitative assessment of insulation deficiencies in insulated bodies and may assist in improving current designs. Some aspects detected as factors decreasing the effectiveness of insulation in the vehicles surveyed during this study include: the thinning of insulation in structural pockets to fit lights and handles, thermal bridges in the form of metallic structures (e.g. latches, structural ribs, hinges, rivets or screws) and poor bonding of materials between the horizontal walls (roof and floor) and sidewalls, amongst others.

8 The interpretation of the images requires background knowledge of the characteristics of the insulated bodies surveyed and the effect of the surveying conditions (e.g. solar radiations, shadows, emissivity of surfaces) on the results. Future research focused on thermographic imaging, as a tool to perform quantitative surface temperature mapping of truck bodies, could enable its use as an accurate measure of local thermal resistivity. Thermography can also be a valuable tool during design optimisation of insulated bodies, enabling the calculation of relative contributions of design features on the overall heat leakage value. It would also allow comparison of materials, interventions, dimensioning tolerances and other features, in terms of their effect in improving the efficiency of insulation. ACKNOWLEDGEMENTS The authors gratefully acknowledge the support of Mr Robert Itaoui and Mr Micheal Gammon during the development of this project. REFERENCES 1. Meola, C., Carlomagno, G. and Giorleo, L The use of infrared thermography for materials characterization. Journal of Materials Processing Technology : Avdelidis, N.P. and Moropoulou, A Emissivity considerations in building thermography. Energy and Buildings 35: Meola, C., Carlomagno, G., Squillace, A. and Giorleo, L The use of infrared thermography for nondestructive evaluation of joints Infrared Physics & Technology 46: Birk, A.M. and Cunningham, M.H Thermographic Inspection of Rail-Car Thermal Insulation. Transactions of the ASME, 122: Standards Australia AS : Thermal performance of refrigerated transport equipment Specification and testing. 54 pp. 6. Estrada-Flores S and Tanner, D Linking the Cold Chain. Loaded: Trailer and Body Technology. (Aug-Sept): p NOMENCLATURE K value overall heat transfer coefficient (W m -2 K -1 )

EVALUATION OF THE THERMAL PERFORMANCE OF FIVE REFRIGERATED VANS

EVALUATION OF THE THERMAL PERFORMANCE OF FIVE REFRIGERATED VANS EVALUATION OF THE THERMAL PERFORMANCE OF FIVE REFRIGERATED VANS S. ESTRADA-FLORES, A. EDDY and N. SMALE Supply Chain Innovation, Food Science Australia PO Box 52, North Ryde, NSW 7, Australia. Fax: +61

More information

EXTRA DURABILITY BY DESIGN TO LOWER YOUR LIFECYCLE COST

EXTRA DURABILITY BY DESIGN TO LOWER YOUR LIFECYCLE COST EXTRA DURABILITY BY DESIGN TO LOWER YOUR LIFECYCLE COST With maximized strength-to-weight ratio, Kidron s Emperor G2 trailer introduces a new generation of food service distribution advantages, uniquely

More information

Sectional Overhead Doors SECTIONAL OVERHEAD DOORS

Sectional Overhead Doors SECTIONAL OVERHEAD DOORS Sectional Overhead Doors SECTIONAL Introduction WHY SPECIFY AND SELECT INSULATED SECTIONAL? This leaflet is offered by A& C M aintenance when presenting the arguments in favour of specification and selection

More information

REPORT ON COMPARATIVE AIR LEAKAGE PERFORMANCE:

REPORT ON COMPARATIVE AIR LEAKAGE PERFORMANCE: REPORT ON COMPARATIVE AIR LEAKAGE PERFORMANCE: Knight Wall with Carlisle 705FR-A and Dow Styrofoam Ultra SL Compared To Z-Girts with Carlisle 705FR-A and Roxul CavityRock PROJECT: LOCATION: Knight Wall

More information

H-Body Sealants Guide

H-Body Sealants Guide H-Body Sealants Guide "Attention: The information contained in this sealant guide was created by Winnebago Industries, Inc. for manufacturing purposes. Sealing processes and the type of sealant used can

More information

3-Dimensional Thermal Analysis of Lenmak EnvaTherm and SpandrelTherm Backpan Assemblies

3-Dimensional Thermal Analysis of Lenmak EnvaTherm and SpandrelTherm Backpan Assemblies Report Number: 5160440 August 18 th, 2016 3-Dimensional Thermal Analysis of Lenmak EnvaTherm and SpandrelTherm Backpan Assemblies Presented to: Lenmak Exterior Innovations Inc. 10404-176 Street Edmonton,

More information

Tectainers. Special Purpose Containers. Comtainer Options Pty Limited Cnr Pine & Loftus Roads, Yennora P O Box 1011 Fairfield NSW 1860

Tectainers. Special Purpose Containers. Comtainer Options Pty Limited Cnr Pine & Loftus Roads, Yennora P O Box 1011 Fairfield NSW 1860 Tectainers TM Special Purpose Containers Comtainer Options Pty Limited Cnr Pine & Loftus Roads, Yennora P O Box 1011 Fairfield NSW 1860 Tel: +61 (2) 9892 2822 Fax: +61 (2) 9892 2522 E-mail: sales@containeroptions.com.au

More information

Cut-A-Way - City Max Refrigerated

Cut-A-Way - City Max Refrigerated Cut-A-Way - City Max Refrigerated From Produce to Poultry, Flowers to Fresh Fish, or Ice to Ice Cream Morgan KNOWS what it takes to design and build the refrigerated truck you need to maintain the perfect

More information

GREAT DANE S NEW i-van IS A VERSATILE TRAILER DESIGNED AND ENGINEERED TO OFFER SEMI-INSULATED PROPERTIES IN CONJUNCTION WITH THE STRENGTH AND

GREAT DANE S NEW i-van IS A VERSATILE TRAILER DESIGNED AND ENGINEERED TO OFFER SEMI-INSULATED PROPERTIES IN CONJUNCTION WITH THE STRENGTH AND GREAT DANE S NEW i-van IS A VERSATILE TRAILER DESIGNED AND ENGINEERED TO OFFER SEMI-INSULATED PROPERTIES IN CONJUNCTION WITH THE STRENGTH AND DURABILITY OF THE CLASSIC DRY FREIGHT VAN. i-van REPRESENTS

More information

Thermal imaging of the outer surface of the Laboratory for engines and vehicles at the Faculty of mechanical engineering and naval architecture

Thermal imaging of the outer surface of the Laboratory for engines and vehicles at the Faculty of mechanical engineering and naval architecture Thermal imaging of the outer surface of the Laboratory for engines and vehicles at the Faculty of mechanical engineering and naval architecture Doris Županić, Antonio Bolarić, Mia Stančić, Denis Piljek,

More information

1 of 1 04/09/ :41

1 of 1 04/09/ :41 1 of 1 04/09/2008 06:41 Buried Shipping Containers http://web.archive.org/web/20031124215255/www.cont 1 of 5 04/09/2008 06:41 DO IT YOURSELF...Partial Burial Example FIND A SITE AND EXCAVATE FOR A PARTIAL

More information

ThermaSteel Corporation ASSEMBLY MANUAL

ThermaSteel Corporation ASSEMBLY MANUAL ThermaSteel Corporation ASSEMBLY MANUAL TABLE OF CONTENTS 1- INTRODUCTION 1.1 THERMASTEEL TM WALL PANELS 1.2 Drawing and Element Numbers 2- ASSEMBLY 2.1 Sequence of Assembly 2.2 Preparation of Foundation

More information

HOME APPLIANCES START WITH SMART SOLUTIONS

HOME APPLIANCES START WITH SMART SOLUTIONS HOME APPLIANCES START WITH SMART SOLUTIONS 1 OUR CORE COMPETENCIES CONTENT Manufacturers of home appliances strive for aesthetic appeal and functionality as well as process optimization and innovation.

More information

VERTEX. different. Molded Fiberglass Composite Shelters

VERTEX. different. Molded Fiberglass Composite Shelters VERTEX Molded Fiberglass Composite Shelters different Vertex shelters are unique: joint-less molded fiberglass outer and inner shells with a foamed-in-place polyurethane foam core between, to produce the

More information

T h e r m a l S c a n n i n g R e p o r t

T h e r m a l S c a n n i n g R e p o r t Infrared Certified Infrared Inspection Services T h e r m a l S c a n n i n g R e p o r t Description: Thermal Energy Loss Comparison A Qualitative Survey PO Box 6126 Stuart, Fl. 34997 We Bring Bad Things

More information

European Timber Windows & Doors

European Timber Windows & Doors European Timber Windows & Doors Providers of Passivhaus building performance solutions Passive House Pty Ltd 7-9 Raglan St North Melbourne VIC p 03 9329 3693 e info@passivehouse.com.au Building Thermal

More information

COLLEGE CLASSROOM & DORMITORY SPECIFICATION SECTION 08100

COLLEGE CLASSROOM & DORMITORY SPECIFICATION SECTION 08100 COLLEGE CLASSROOM & DORMITORY SPECIFICATION SECTION 08100 Part 1 General 1.01 Work Included A. The work under this section shall include the furnishing of all items shown on the drawings and as specified,

More information

HOTEL SPECIFICATION SECTION 08100

HOTEL SPECIFICATION SECTION 08100 Part 1 General HOTEL SPECIFICATION SECTION 08100 1.01 Work Included A. The work under this section shall include the furnishing of all items shown on the drawings and as specified including, but not limited

More information

SP Standard Profile. Flanged to Duct Install Type THERMAL BREAKS OPPOSED ACTION PARALLEL ACTION. T.A. Morrison & Co. Inc.

SP Standard Profile. Flanged to Duct Install Type THERMAL BREAKS OPPOSED ACTION PARALLEL ACTION.  T.A. Morrison & Co. Inc. 1 SUBMITTAL DATA Series 9000 BF Thermally Insulated Damper with Thermally Broken Frames & Blades SP Standard Profile Flanged to Duct Install Type THERMAL BREAKS OPPOSED frame is 4 (101.6 mm) deep x 1 (25.4

More information

Air Container Search Procedures

Air Container Search Procedures Air Container Search Procedures Presenter s Name June 17, 2003 2 Methodology Standardize your approach Train and retrain your staff Keep it simple Have a process in place to provide extra screening for

More information

1. Supply, delivery, engineering and installation of new storage equipment.

1. Supply, delivery, engineering and installation of new storage equipment. SECTION 10 51 13 - METAL LOCKERS * ALL FIELDS IN [ ] MUST BE EDITED PART 1 - GENERAL 1.1. RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions

More information

AUTHORIZED SIKA DISTRIBUTOR PRODUCT SELECTOR GUIDE FOR MINERAL GLASS

AUTHORIZED SIKA DISTRIBUTOR PRODUCT SELECTOR GUIDE FOR MINERAL GLASS AUTHORIZED SIKA DISTRIBUTOR PRODUCT SELECTOR GUIDE FOR MINERAL GLASS MINERAL GLASS BONDING AND SEALING Part 1: Non-UV-exposed applications Sika offers a wide range of technologies and products for bonding

More information

and FIBERGLASS FOAM AND HOLLOW CORE BUILDING PANELS

and FIBERGLASS FOAM AND HOLLOW CORE BUILDING PANELS and FIBERGLASS FOAM AND HOLLOW CORE BUILDING PANELS DURASHIELD Fiberglass Foam Core Building Panels Features The DURASHIELD panel is a tongue-and-groove fiberglass pultruded panel comprised of a pultruded

More information

FOCAL POINT RENDAPANEL TM CLADDING SYSTEM

FOCAL POINT RENDAPANEL TM CLADDING SYSTEM FOCAL POINT RENDAPANEL TM CLADDING SYSTEM strength and durability SYSTEM INFORMATION & TECHNICAL SPECIFICATION V4 2002 Page 1 of 7 INTRODUCTION Monolithic Light Weight Cement Render Cladding RendaPanel

More information

In alliance with. Green AppeAl

In alliance with. Green AppeAl In alliance with Green AppeAl About us of Eutectic System Refrigerated Bodies for the distribution of ice cream and frozen food. Founded in 1950, when Franger Group decided to start a new business: the

More information

Dagard-Taïga/UK 28/02/02 11:50 Page 1 aïga Cold Room T

Dagard-Taïga/UK 28/02/02 11:50 Page 1 aïga Cold Room T Taïga Cold Room Taiga is designed for the storage of perishables, in the retail, catering and supermarket sectors The various environmental and operating requirements (ceiling height, type of premises,

More information

SECTION FIBERGLASS REINFORCED POLYESTER (FRP) DOORS AND ALUMINUM FRAMES

SECTION FIBERGLASS REINFORCED POLYESTER (FRP) DOORS AND ALUMINUM FRAMES SECTION 081613 FIBERGLASS REINFORCED POLYESTER (FRP) DOORS AND ALUMINUM FRAMES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary

More information

RS24-10 Single-Section Skylight System

RS24-10 Single-Section Skylight System INSTALLATION INSTRUCTIONS RS24-10 VERSION 1.100316 DATED: 10/03/16 RS24-10 Single-Section Skylight System under/over seam clip double diverter US Patent D750,282 www.rnssales.com sales@rnssales.com 805.375.3980

More information

Non Destructive Energy Evaluation

Non Destructive Energy Evaluation Non Destructive Energy Evaluation Prepared for: DoubleTree Hilton Baltimore North Pikesville 1726 Reisterstown Rd Pikesville, MD 21208 Prepared by: Thomas Hurley and Jeremy Moore HurleyIR, Inc. 4757 Buffalo

More information

JRS ENGINEERING. Continuous Insulation Overall Effective. Presented by: Marty Deemter, P.Eng. Scott Croasdale, M.Eng, P.Eng, PE

JRS ENGINEERING. Continuous Insulation Overall Effective. Presented by: Marty Deemter, P.Eng. Scott Croasdale, M.Eng, P.Eng, PE JRS ENGINEERING Building Envelope Consultants Continuous Insulation Overall Effective R-Value of Exterior Walls Presented by: Marty Deemter, P.Eng. Developed by: Scott Croasdale, M.Eng, P.Eng, PE Topics

More information

Sound-absorbing and sound-insulating barriers

Sound-absorbing and sound-insulating barriers Sound-absorbing and sound-insulating barriers innovative and biocompatible solutions for the environment sound-insulation Sound-absorbing and sound-insulating noise barriers for road and rail traffic are

More information

White Roofs may not be so Green

White Roofs may not be so Green White Roofs may not be so Green Gregory Stockton RoofScanIR.com, a division of United Infrared, Inc. ABSTRACT While an enormous amount of infrared techniques to look at building efficiency have been developed

More information

WEATHER BREAKER MODEL 175 QUALITY DOOR SOLUTIONS SINCE 1947

WEATHER BREAKER MODEL 175 QUALITY DOOR SOLUTIONS SINCE 1947 WEATHER BREAKER MODEL 175 QUALITY DOOR SOLUTIONS SINCE 1947 WEATHER BREAKER MODEL 175 Whether you are keeping the cold out or in, nothing makes better sense for your manufacturing facility or warehouse

More information

MECHANICAL LEVELERS. P.O. Box 338 Spring Hill, Tennessee /486/ /251/3382 Fax 931/486/0316

MECHANICAL LEVELERS. P.O. Box 338 Spring Hill, Tennessee /486/ /251/3382 Fax 931/486/0316 EDE & BLE Owner s Manual MECHANICAL LEVELERS P.O. Box 338 Spring Hill, Tennessee 37174 931/486/2296 800/251/3382 Fax 931/486/0316 www.pioneerleveler.com SM SECTION 1 RECEIVING: INSTALLATION INSTRUCTIONS

More information

K. ASTM F436- Standard Specification for Hardened Steel Washers; 2011.

K. ASTM F436- Standard Specification for Hardened Steel Washers; 2011. DIVISION 05 METALS 05 12 00 STRUCTURAL STEEL FRAMING PART 1 GENERAL 1.1 SECTION INCLUDES A. Structural steel framing members, support members. 1.2 RELATED REQUIREMENTS A. Section 05 50 00 - Metal Fabrications:

More information

SECTION COLD-FORMED METAL TRUSSES

SECTION COLD-FORMED METAL TRUSSES SECTION 054400 COLD-FORMED METAL TRUSSES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Standard Practice for Thermographic Inspection of Insulation Installations in Envelope Cavities of Frame Buildings 1

Standard Practice for Thermographic Inspection of Insulation Installations in Envelope Cavities of Frame Buildings 1 Designation: C 1060 90 (Reapproved 1997) e1 Standard Practice for Thermographic Inspection of Insulation Installations in Envelope Cavities of Frame Buildings 1 This standard is issued under the fixed

More information

HAAS-THERM. Commercial Insulated Steel Doors. Models CHT-710, CHT-716, CHT-732, CHT-780, and CHT-790

HAAS-THERM. Commercial Insulated Steel Doors. Models CHT-710, CHT-716, CHT-732, CHT-780, and CHT-790 HAAS-THERM Commercial Insulated Steel Doors Models CHT-710, CHT-716, CHT-732, CHT-780, and CHT-790 1-3/4 Thick CFC-Free, Foam-Injected Polyurethane Core HAAS-THERM commercial insulated sectional doors

More information

SMART FIXING SYSTEMS profiles pro ofilees

SMART FIXING SYSTEMS profiles pro ofilees SMART FIXING SYSTEMS profiles 2 www.plastestrip.com T +44(0)1726 74771 F +44(0)1726 69238 sales@plastestrip.com REAR-VENTILATED FACADE The hung, rear-ventilated facade (RVF) covers the load bearing wall

More information

INSTALLATION MANUAL FOR MODULAR EXPANSION JOINT (LG SYSTEM)

INSTALLATION MANUAL FOR MODULAR EXPANSION JOINT (LG SYSTEM) INSTALLATION MANUAL FOR MODULAR EXPANSION JOINT (LG SYSTEM) TABLE OF CONTENTS 1. INTRODUCTION TO THE MODULAR EXPANSION JOINT 1.1 Purpose 1.2 How They Work 1.3 Movement Capacity 1.3.1 Longitudinal Direction

More information

SECTION METAL DOORS & FRAMES

SECTION METAL DOORS & FRAMES SECTION 08100 METAL DOORS & FRAMES PART 1 GENERAL 1.1 SCOPE Drawings and general provisions of the Contract, including General and Supplementary General Conditions and other Division 00 & 01 specification

More information

Project No: Pakenham Branch Library, Pakenham, Ontario Section DECEMBER, 2016 Page 1 of 6

Project No: Pakenham Branch Library, Pakenham, Ontario Section DECEMBER, 2016 Page 1 of 6 DECEMBER, 2016 Page 1 of 6 1 GENERAL 1.01 RELATED SECTIONS.1 Section 01 33 00 - Submittal Procedures..2 Section 07 21 16 - Batt and Blanket Insulation..3 Section 07 92 10 - Sealants..4 Section 09 91 00

More information

lindab we simplify construction LindabSandwichPanels Installation instructions Mineral Wool Panels

lindab we simplify construction LindabSandwichPanels Installation instructions Mineral Wool Panels lindab we simplify construction LindabSandwichPanels Installation instructions Mineral Wool Panels Assembly instructions Handling Receiving of goods Check that the material has not been damaged in transit

More information

NORDSTROM factories are required to perform a seven-point inspection process designed to verify the physical integrity of the container.

NORDSTROM factories are required to perform a seven-point inspection process designed to verify the physical integrity of the container. 1. Container Security Container integrity must be maintained to protect against the introduction of unauthorized material and/or persons. Factory-loaded full containers must have written and verifiable

More information

Infrared Thermography for the Characterization of Painted Vaults of Historic Masonry Buildings Claudia Casapulla, Alessandra Maione, Luca Umberto

Infrared Thermography for the Characterization of Painted Vaults of Historic Masonry Buildings Claudia Casapulla, Alessandra Maione, Luca Umberto of Claudia Casapulla, Alessandra Maione, Luca Umberto Argiento and Andrea Prota Department of Structures for Engineering and Architecture, University of Naples Federico II, Italy Outline Motivation of

More information

Quality Control Inspection of Homes with Thermal Imaging

Quality Control Inspection of Homes with Thermal Imaging Quality Control Inspection of Homes with Thermal Imaging Sampling of Thermal Images collected during a study of construction quality of homes built recently in the five most populous parishes of Louisiana

More information

B41XTCE Gas Fireplace

B41XTCE Gas Fireplace B1XTCE Gas Fireplace Model B1XTCE-NG1 B1XTCE-LP1 Fuel Type Natural Gas Propane Minimum Supply Pressure 5 W.C./C.E. (1.5 kpa) 11 W.C./C.E. (.7 kpa) Manifold Pressure - High 3.5 W.C./C.E. (.7 kpa) 1 W.C./C.E.

More information

Innovative Coatings Technologies

Innovative Coatings Technologies Innovative Coatings Technologies High Performance Coatings Insulation and Encapsulation Solutions Superior Products International II, Inc. 1 SPI Family of Coatings Insulation / Fire Control Super Therm

More information

Delta Level 1000 Hinged Lip Pit Mounted & Suspended Frame Dock Leveller

Delta Level 1000 Hinged Lip Pit Mounted & Suspended Frame Dock Leveller Delta Level 1000 Hinged Lip Pit Mounted & Suspended Frame Dock Leveller Product Description The Delta Level 1000 is one of our ranges of hinged lip dock levellers. Dock levellers are indispensable for

More information

Flushglaze For Steel Tube Applications and Horizontal Panels. Façades Installation Guide

Flushglaze For Steel Tube Applications and Horizontal Panels. Façades Installation Guide Flushglaze 7500 For Steel Tube pplications and Horizontal Panels Façades Installation Guide September 2016 BENCHMRK Welcome to Kingspan, global leaders in the design and manufacture of insulated metal

More information

HUMBAUR is optimising distribution transport with its FlexBox. Gersthofen, 21. September 2016

HUMBAUR is optimising distribution transport with its FlexBox. Gersthofen, 21. September 2016 Through load, save space and remain flexible The HUMBAUR through loading combination with tail lift result in happy and satisfied CEP service providers HUMBAUR is optimising distribution transport with

More information

Multi-Fab sells to registered dealers only; however, we can assist in finding you a dealer.

Multi-Fab sells to registered dealers only; however, we can assist in finding you a dealer. ATTACHMENTS This term refers to implements that can be added to a fork truck for handling a load. Attachments such as clamps, slip sheet forks and carpet poles can have an effect on capacity and should

More information

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection SECTION 13090 RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection Prepared by: 90 Dayton Avenue, Unit 4B, Suite 13 Passaic, NJ 07055 (973) 574-9077 13090-1 LOW INTENSITY RADIATION PROTECTION

More information

Renting a shipping container..?? Read this check list..

Renting a shipping container..?? Read this check list.. Renting a shipping container..?? Read this check list.. Looking for a shipping container for hire in Adelaide..?? Look no further.. Port Container Services are a reliable shipping container supplier in

More information

Central Station Air Handler Specification

Central Station Air Handler Specification Central Station Air Handler Specification PART 1: GENERAL 1.01 WORK INCLUDED (Model CS 3 ) Mechanical Specification A. Provide complete air handling unit(s) suitable for indoor installation. Contractor

More information

Glasboard Liners. installation details. Installation Guide for Glasbord Fibreglass Reinforced Plastic (FRP) panels

Glasboard Liners. installation details. Installation Guide for Glasbord Fibreglass Reinforced Plastic (FRP) panels Glasboard Liners installation details Installation Guide for Glasbord Fibreglass Reinforced Plastic (FRP) panels PLEASE READ ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION These guidelines are provided

More information

Using a Building s HVAC Systems and Infrared Technology to Solve Water Intrusion Problems

Using a Building s HVAC Systems and Infrared Technology to Solve Water Intrusion Problems Using a Building s HVAC Systems and Infrared Technology to Solve Water Intrusion Problems James Brady Level III Certified Infrared Thermographer Brady Infrared Inspections, Inc. 935 Pine Castle Court Stuart,

More information

DALAL FLAT PACK MODULAR UNITS

DALAL FLAT PACK MODULAR UNITS DALAL FLAT PACK MODULAR UNITS TECHNICAL SPECIFICATIONS MATERIAL Floor Roof Walls Doors Windows Electrical Works Main and Secondary Galvanized steel framing. Marine Plywood with PVC for dry areas and Cement

More information

REI ENGINEERS S. TAMIAMI TRAIL, SUITE , BONITA SPRINGS, FL PHONE FAX

REI ENGINEERS S. TAMIAMI TRAIL, SUITE , BONITA SPRINGS, FL PHONE FAX REI ENGINEERS 24600 S. TAMIAMI TRAIL, SUITE 212-315, BONITA SPRINGS, FL 34134 PHONE 800.495.9028 FAX 239.498.7447 Infrared Moisture Evaluation 14025, 58 th St N, Clearwater, FL 33760 Client: Representative:

More information

Protective devices according to EN ISO 12100

Protective devices according to EN ISO 12100 devices according to EN ISO 12100 PLUS PROTECT-PANEL page 590 589 PLUS PROTECT-PANEL system High speeds, quick machining cycles, cooling water and chips: Machine tools represent a dangerous environment

More information

SECTION OVERHEAD DOORS. Summary of Structural Steelwork Drawings SECT IONAL OVERH EAD D OORS

SECTION OVERHEAD DOORS. Summary of Structural Steelwork Drawings SECT IONAL OVERH EAD D OORS Summary of Structural Steelwork Drawings 550 min headroom 400 min headroom INSULATED GARAGE INSULATED REPAIR PANELS OSA Door Parts, Unit 4, Ashville Industrial Estate, Runcorn, Cheshire, WA7 3EZ. UK. HIGH

More information

DICTATOR Lift Shaft System

DICTATOR Lift Shaft System DICTATOR Lift Shaft System The Modular Lift Shaft System, also for Retrofitting Certified According to EN 1090 A lift is becoming more and more important for daily life, not only in newly constructed buildings

More information

INSTALLATION INSTRUCTIONS for MP-RC1 TWO PIECE CONSTRUCTION TO BE INSTALLED ON COMPLETED ROOF DECK

INSTALLATION INSTRUCTIONS for MP-RC1 TWO PIECE CONSTRUCTION TO BE INSTALLED ON COMPLETED ROOF DECK INSTALLATION INSTRUCTIONS for MP-RC1 TWO PIECE CONSTRUCTION TO BE INSTALLED ON COMPLETED ROOF DECK A. 1. Using curb ribs as a guide, layout and mark roof openings on completed roof deck as outside curb

More information

SMART FIXING SYSTEMS

SMART FIXING SYSTEMS SMART FIXING SYSTEMS REAR-VENTILATED FACADE The hung, rear-ventilated facade (RVF) covers the load bearing wall of a building. With a RVF, the facade elements are mounted with the help of a fixing system

More information

Sikaflex 221 is a high-adhesion, polyurethane-based sealing compound for Low-odour

Sikaflex 221 is a high-adhesion, polyurethane-based sealing compound for Low-odour GLUING AND RIVETING Sikaflex 221, black Elastic Sikaflex 221 is a high-adhesion, polyurethane-based sealing compound for Low-odour connecting and overlapping joints, apron panels, trims, floor assemblies

More information

De Montfort Mark 7 Incinerator (Flatpack)

De Montfort Mark 7 Incinerator (Flatpack) De Montfort Mark 7 Incinerator (Flatpack) Introduction This design is specially for those occasions when a large number of incinerators are to be built at one location and transported to the places where

More information

All Metals Fabrication AMF FUSION DRILLFREE ALUMINUM COMPOSITE METAL (ACM) WALL PANEL SPECIFICATION

All Metals Fabrication AMF FUSION DRILLFREE ALUMINUM COMPOSITE METAL (ACM) WALL PANEL SPECIFICATION SECTION 07 42 43 All Metals Fabrication AMF FUSION DRILLFREE ALUMINUM COMPOSITE METAL (ACM) WALL PANEL SPECIFICATION SPEC NOTE: Optional text is indicated by square brackets []. Delete unwanted items and

More information

SECTION ACCESS DOORS AND FRAMES

SECTION ACCESS DOORS AND FRAMES SECTION 08310 ACCESS DOORS AND FRAMES PART 1 - GENERAL 1.1 SUMMARY A. Section includes: 1. [Fire rated] [and] [Non-fire rated] wall access panels. 2. [Fire rated] [and] [Non-fire rated] ceiling access

More information

Text Slide. Container and Seal Inspection Workshop

Text Slide. Container and Seal Inspection Workshop Text Slide Container and Seal Inspection Workshop 1 Inspection Workshop Intro This inspection workshop is intended to help you recognize containers and seals that have been compromised for the purpose

More information

SECTION ALUMINUM-FRAMED HIGH PERFORMANCE THERMAL ENTRANCE DOORS

SECTION ALUMINUM-FRAMED HIGH PERFORMANCE THERMAL ENTRANCE DOORS PART 1 GENERAL SECTION 08 1116 ALUMINUM-FRAMED HIGH PERFORMANCE THERMAL ENTRANCE DOORS 1.01 SECTION INCLUDES A. Aluminum-framed storefront, with vision glass. B. Infill panels of glass. C. Aluminum doors

More information

Thermal Imaging. By Colin Pearson Head of Condition Monitoring BSRIA

Thermal Imaging. By Colin Pearson Head of Condition Monitoring BSRIA Thermal Imaging In Association with Anderson Mechanical Services Loughgall, Armagh BT61 8HZ www.andersonmechanical.net Email: info@andersonmechanical.net By Colin Pearson Head of Condition Monitoring BSRIA

More information

LATRINE CONSTRUCTION SHELTER. Pour flush latrine 2. Pour flush micro septic tank 3. Initial investment, location, human resources 4.

LATRINE CONSTRUCTION SHELTER. Pour flush latrine 2. Pour flush micro septic tank 3. Initial investment, location, human resources 4. LATRINE CONSTRUCTION Pour flush latrine 2 Pour flush micro septic tank 3 Initial investment, location, human resources 4 Concrete rings 5 Box 6 Cover 7 Slab and ceramic pan 8 Ring mold 9 Structure and

More information

SUBMITTAL PACKAGE CUSTOM HOLLOW METAL DOORS, FRAMES AND WINDOWS

SUBMITTAL PACKAGE CUSTOM HOLLOW METAL DOORS, FRAMES AND WINDOWS Box 1101, 140 Coal St. Raton, NM 87740 Phone 575-445-2756 Fax: 575-445-2804 SUBMITTAL PACKAGE CUSTOM HOLLOW METAL DOORS, FRAMES AND WINDOWS DATE: PROJECT: LOCATION: CONTRACTOR: QUANITITY: DOORS: FRAMES:

More information

Contents. Timber framing to be installed in accordance with AS:1684 Metal framing to be installed in accordance with BCA Volume: 2

Contents. Timber framing to be installed in accordance with AS:1684 Metal framing to be installed in accordance with BCA Volume: 2 Contents BCA Codes 3 General 4 Fire Performances Thermal and Acoustic Insulation Wall Installation 4 Timber Frame Separation Walls 5 Steel Frame Separation Walls 6 External Fire Rated Walls 7 Floor Installation

More information

B. Polyethylene samples shall be submitted for Owner approval of color and quality.

B. Polyethylene samples shall be submitted for Owner approval of color and quality. Glass Rail ENGINEERED DASHERBOARD SPECIFICATIONS PART 1 - GENERAL 1.01 PROJECT SCOPE A. Contractor shall furnish and install one complete set of steel framed dasherboards as indicated on the drawings and

More information

VAULT. VIntegrated Storage and Filing wall

VAULT. VIntegrated Storage and Filing wall vault VIntegrated Storage and Filing wall VAULT 20 Filing, storage and space division: VAULT is the answer to all of these challenges. With clean lines and minimal base heights, it is compatible with Dwel

More information

Mario D. Gonçalves, Patenaude-Trempe 1 Pierre Gendron, Patenaude-Trempe 2 Tony Colantonio, PWGSC 3. Abstract

Mario D. Gonçalves, Patenaude-Trempe 1 Pierre Gendron, Patenaude-Trempe 2 Tony Colantonio, PWGSC 3. Abstract Commissioning of Exterior Building Envelopes of Large Buildings for Air Leakage and Resultant Moisture Accumulation using Infrared Thermography and Other Diagnostic Tools Mario D. Gonçalves, Patenaude-Trempe

More information

Thermatile Ten-Twelve Radiant Panels. Installation instructions

Thermatile Ten-Twelve Radiant Panels. Installation instructions Thermatile Ten-Twelve Radiant Panels Installation instructions 2 IOM 53, Issue 6 - Thermatile TEN-TWELVE Contents Page 1 General 3 1.1 Description 3 1.2 Receipt and Preparation 3 1.3 Storage and Handling

More information

Container Installation Guide

Container Installation Guide Container Insulation Container Installation Guide Panels and Inserts The InSoFast CX Container panel and the Inserts are designed to fit most shipping containers. Containers have three types of corrugations:

More information

Secure Storage On Demand

Secure Storage On Demand Western Steel & Tube Ltd. Secure Storage On Demand Modular Containers Multiple uses for agricultural, commercial, and residential applications. Secure Storage On Demand Western Steel & Tube Ltd. Ph: 204.475.4966

More information

guarantee successful solutions. of which 7000 are covered, today Framec Truck is a through a wide range of highly sophisticated

guarantee successful solutions. of which 7000 are covered, today Framec Truck is a through a wide range of highly sophisticated Green AppeAl 2 About us Our mission MISSION of Eutectic System Refrigerated Bodies for the distribution of ice cream and frozen food. The mission of Framec Truck is to make the proximity service of foodstuff

More information

For more information on Pictura visit CI/SfB (41) R December New. Pictura. High performance cladding

For more information on Pictura visit   CI/SfB (41) R December New. Pictura. High performance cladding New CI/SfB (41) R December 2008 Pictura High performance cladding Introduction The new Pictura coating system incorporates an additional surface treatment for Fibre Cement panels. The main characteristic

More information

Break it, or Lose it: Thermal Bridging in Building Envelopes

Break it, or Lose it: Thermal Bridging in Building Envelopes Break it, or Lose it: Thermal Bridging in Building Envelopes NESEA BuildingEnergy 16 March 9, 2016 INTRODUCTION Learning Objectives 1. Learn the significance that thermal bridges can have on decreasing

More information

RS32 Multi-Section Skylight System under/over seam clip double diverter

RS32 Multi-Section Skylight System under/over seam clip double diverter INSTALLATION INSTRUCTIONS RS32-x RS32 Multi-Section Skylight System under/over seam clip double diverter www.rnssales.com sales@rnssales.com 805.375.3980 Fax 805.375.3981 SKYLIGHT ACRYLIC skyline series

More information

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Union County Vocational - Technical Schools Scotch Plains, New Jersey SECTION 092216 - NON-STRUCTURAL METAL FRAMING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

[Project Name] Section [ ]

[Project Name] Section [ ] Page 1 PART 1 - GENERAL 1.1 SECTION INCLUDES 1.1.1 Design, labor, products, equipment and services necessary for interior/exterior Aluminum Facade System (AFS) work, in accordance with the Contract Documents.

More information

SECTION IMPACT RESISTANT WALL PROTECTION

SECTION IMPACT RESISTANT WALL PROTECTION SECTION 10265 PART I - GENERAL 1.01 DESCRIPTION A. Scope: Work under this Section shall include all materials and installation necessary to provide Impact-Resistant Wall Protection including Wall guards,

More information

Building Your Visions

Building Your Visions Ferguson C EAP Curtain Wall Systems Ferguson-EAP 130HP Series High Performance Curtain Wall System Ferguson s 130HP curtain wall system was developed for high performance double, triple, unique acoustical

More information

SECTIONAL OVERHEAD DOORS

SECTIONAL OVERHEAD DOORS Common applications: Ideal for industrial and commercial premises for complete security available manual push up, chain operated or electric operated either single or three phase. Insulated and powder

More information

Specifications for Insulation Board wall and ceiling applications

Specifications for Insulation Board wall and ceiling applications Specifications for Insulation Board wall and ceiling applications Product Ref: Marmox Multiboard 600mm wide, 1250/2500mm long. 10, 12.5, 20, 30, 40, 50, 60mm thick. Also known as Marmox Board- Pro and

More information

MISER-THERM. Commercial Insulated Steel Doors. Models CMT-610, CMT-616, CMT-680, and CMT-690

MISER-THERM. Commercial Insulated Steel Doors. Models CMT-610, CMT-616, CMT-680, and CMT-690 MISER-THERM Commercial Insulated Steel Doors Models CMT-610, CMT-616, CMT-680, and CMT-690 1-3/8 Thick CFC-Free, Foam-Injected Polyurethane Core Haas Door s MISER-THERM commercial insulated sectional doors

More information

LOADING DOCK SYSTEMS HIGH SPEED DOORS LIFT TABLES DOCK SHELTERS SECTIONAL DOORS COMPL. FOOD INDUSTRY L O A D I N G D O C K S Y S T E M S

LOADING DOCK SYSTEMS HIGH SPEED DOORS LIFT TABLES DOCK SHELTERS SECTIONAL DOORS COMPL. FOOD INDUSTRY L O A D I N G D O C K S Y S T E M S LOADING DOCK SYSTEMS HIGH SPEED DOORS LIFT TABLES DOCK SHELTERS SECTIONAL DOORS COMPL. FOOD INDUSTRY L O A D I N G D O C K S Y S T E M S LOADING DOCK SYSTEMS LOADING DOCK SYSTEMS Loading dock systems enable

More information

Stack Parking Surface Mounted Stackers

Stack Parking Surface Mounted Stackers 1 / 6 Stack Parking Surface Mounted Stackers swiss-park V-2 Comfort The V-2 is designed to park cars of any size thanks to its vertical adjustability. It will accommodate cars as tall as the garage ceiling

More information

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Union County Vocational - Technical Schools Scotch Plains, New Jersey SECTION 102239 - FOLDING PANEL PARTITIONS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Thermal Imaging Report

Thermal Imaging Report Thermal Imaging Report 123 Renovation Street Manalapan, NJ 07726 Prepared for: Mr. and Mrs. Homeowner Prepared by: A Full House Inspection Co. LLC 530 Prospect Avenue Little Silver, NJ 07739 Prepared by

More information

OPTIWIN MOTURA. Technical Description. Synopsis:

OPTIWIN MOTURA. Technical Description. Synopsis: Technical Description OPTIWIN MOTURA Synopsis: 1. Product "OPTIWIN MOTURA" General Description... 2 2. Materials... 3 2.1. Wood... 3 2.2. Surface... 3 2.2.1. Inside... 3 2.2.2. Outer shell... 4 2.3. Glazing...

More information

Thermatile Ten-Twelve Radiant Panels. Installation instructions

Thermatile Ten-Twelve Radiant Panels. Installation instructions Thermatile Ten-Twelve Radiant Panels Installation instructions 2 IOM 53, Issue 7 - Thermatile TEN-TWELVE Contents Page 1 General 3 1.1 Description 3 1.2 Receipt and Preparation 3 1.3 Storage and Handling

More information

SPECIALIST ACCESSWAY SOLUTIONS. Stainless Steel Hinged Chiller Doors ULTI STAINLESS STEEL DOORS SPECIALIST DOOR SOLUTIONS. ultigroup.co.

SPECIALIST ACCESSWAY SOLUTIONS. Stainless Steel Hinged Chiller Doors ULTI STAINLESS STEEL DOORS SPECIALIST DOOR SOLUTIONS. ultigroup.co. SPECIALIST ACCESSWAY SOLUTIONS Stainless Steel Hinged Chiller Doors ULTI STAINLESS STEEL DOORS SPECIALIST DOOR SOLUTIONS 0800 807 753 ultigroup.co.nz 2 Hinged Stainless Steel Chiller Doors SINGLE AND DOUBLE

More information

SECTION ACCESS DOORS AND FRAMES

SECTION ACCESS DOORS AND FRAMES 11303, 26 th avenue Montreal, Quebec Canada H1E 6N6 Phone: (800) 479-1489 Fax: (800) 297-1489 PRODUCT GUIDE SPECIFICATION SECTION 08 31 00 S PART 1 - GENERAL 1.1 SUMMARY A. Provide access doors, frames

More information

Page 1 PRODUCT DESCRIPTION SECTION SECTIONAL OVERHEAD DOORS MODEL 900 PRODUCT FEATURES

Page 1 PRODUCT DESCRIPTION SECTION SECTIONAL OVERHEAD DOORS MODEL 900 PRODUCT FEATURES 2016-03-24 Page 1 SECTION 08360 SECTIONAL OVERHEAD DOORS DESCRIPTION MODEL 900 PRODUCT FEATURES Sectional steel overhead doors, industrial grade heavy duty construction. BASIC USES / RELATED USES Sectional

More information