Fully Extractive Vs. Dilution Extractive CEMS

Size: px
Start display at page:

Download "Fully Extractive Vs. Dilution Extractive CEMS"

Transcription

1 Fully Extractive Vs. Dilution Extractive CEMS Cemtek Environmental Emissions Seminar & Training Session Santa Ana, CA a technical solution to meet every need CEMTEK Environmental Inc S. Orange Ave. Santa Ana, CA

2 Continuous Emission Monitoring CEMS are required for a variety of different applications and can be found at facilities such as: Turbines-Gas & Oil Fired, Boilers-Gas, Oil & Coal Fired, IC Engines-Landfill Gas, Wastewater Treatment-Sewage Sludge Incinerators & IC Engines, Refinery, Waste to Energy, Cogeneration & Process Applications

3 CEMS & Process Monitors Ambient, Dilution, Full-Extractive Dry, Hot-Wet Extractive Chemiluminescence, Fluorescence, NDIR, GFC, Zirconia, Paramagnetic, Tunable Diode Laser, Heated FID (Flame Ionization Detection) and FTIR Low NOx/NO/NO 2 /NH3/SO 2 /SO 3 /CO/CO 2 /O 2 /VOCs, Mercury, Opacity, Flow, Ozone, Calibrators and PM

4 CEMS TYPES FULLY EXTRACTIVE (DRY BASIS) DILUTION EXTRACTIVE (WET BASIS) OTHERS: FULLY EXTRACTIVE (HOT/WET) IN-SITU (CROSS STACK or PROBE) EX-SITU (CLOSE COUPLED EXTRACTIVE)

5 FULLY EXTRACTIVE - Dry Basis Sample Gas Dried To A Dew-point Of +2 C Excellent Performance In Low Concentrations Good Performance In High Concentrations Requires Preventative Maintenance MEASUREMENT TYPES: Chemiluminescence, NDIR, UV Absorption, UV Fluorescence, Paramagnetic, Zirconia, FTIR, DOAS, IR-GFC Heated Probe Filter And Heated Sample Line Moisture Volume Needs to be Determined Constant or Measured

6 Sample Line Probe NOx Pump Cal Gas Inst. Air Cooler CO O2 Extractive Flow Schematic

7 SAMPLE CONDITIONING BAY

8 SAMPLE COOLER SAMPLE PUMP PERISTALTIC PUMP

9 Fully Extractive Heated Probe

10 SYSTEM CONTROL PANEL SAMPLE FLOW CONTROL PANEL

11 SAMPLE PROBE WITH HEATED FILTER

12 DILUTION EXTRACTIVE - Wet Basis DILUTES SAMPLE WITH CLEAN DRY AIR MINIMIZES MAINTENANCE USES HIGHLY SENSITIVE GAS ANALYZERS LOWER COST SAMPLE LINE FREEZE PROTECTED SIMPLE TO OPERATE MEASUREMENT TYPES: Chemiluminescence (NOx), UV Fluorescence (SO2), GFC-IR (CO), NDIR (CO2 diluent)

13 Dilution Extractive Flow Schematic

14 Blow Back Cal Bypass Dilution (purge) Gas Air Air Stack Vacuum Pressure Comp Diluted Sample Out DILUTION PROBE SCHEMATIC (Out-Of-Stack)

15 Side View Pressure Comp Cal Gas Vacuum Dilution Air Diluted Sample Out DILUTION PROBE ARRANGEMENT (Out-Of-Stack)

16 Bypass Air Top View Heated Filter DILUTION PROBE ARRANGEMENT (Out-Of-Stack)

17 Heated Block Bypass Air Blow Back Air DILUTION PROBE ARRANGEMENT (Out-Of-Stack)

18 DILUTION CONTROL PANEL GAS ANALYZERS

19 TRACE GAS SCRUBBERS ACCUMULATOR TANK HEATLESS AIR DRYER

20 CEMS SELECTION AND DESIGN Application Choices Dilution or Extractive Pollutant Concentrations Lowest constituent dictates May preclude dilution due to analyzer limitations Mass Emissions Requirement Dilution is a wet basis measurement Requires flow measurement

21 APPLICATION CHOICES Dilution or Fully Extractive Advantages Disadvantages Dilution Low maintenance Low concentrations Extractive More reliable (Ratios above 100:1) Coal fired Some oil fired Fully Low concentrations Higher maintenance Extractive Gas fired Lower availability Some oil fired Fuel flow meter

22 Continuous Emissions Monitoring Systems Engineering & Design Gas Turbines a technical solution to meet every need CEMTEK Environmental Inc S. Orange Ave. Santa Ana, CA

23 Gas Turbine Process Diagram Turbine Exhaust CEMS NO X CO O 2 NH 3 * SCR Inlet CEMS NO X Raw Material Dryer THC Regulatory Compliance CEMS Process CEMS

24 Natural Gas Fired Turbine Gas Turbine Air Quality Control Systems CO Catalyst SCR NO X Control

25 Conventional CEMS Ammonia Slip Measurement Techniques Differential NO X /NH 3 Converter Method Turbine Exhaust NO X + Converted NH 3 Turbine Exhaust NO X On Stack Converter 4 NH O 2 = 4 NO + 6 H 2 O *High temperature catalyst NH 3 slip (ppm) = NO X (ppm) (total converted) NO X (ppm) (unconverted)

26 Conventional CEMS Ammonia Slip Measurement Techniques Inlet/Outlet Differential NO X Method Turbine Exhaust NO X SCR Inlet NO X NH 3 slip = NH 3 fed (NO X in NO X out)

27 Direct NH 3 Measurement Method Conventional CEMS Ammonia Slip Measurement Techniques Turbine Exhaust NH 3

28 Continuous Emissions Monitoring Systems Engineering & Design Coal Fired Utility Boilers a technical solution to meet every need CEMTEK Environmental Inc S. Orange Ave. Santa Ana, CA

29 Coal Fired Utility Boiler Process Diagram SCR/SNCR NO X NH 3 Slip Stack Exhaust CEMS NO X Regulatory Compliance CEMS FGD Inlet SO X Compliance/Process CEMS SO 2 CO PM Hg HCl Flow Process CEMS

30 Coal Fired Utility Boiler Air Quality Control Systems SCR/SNCR NO X Control Activated Carbon Injection Mercury Control Particulate/ Opacity Control WFGD/DFGD SO X Control

31 Wet & Dry FGD CEMS Application CEMS Design Considerations Coal Fired Boiler FGD Scrubber General CEMS Design Probe Design and Accessories Corrosion resistant materials for probe tube construction to prevent attack from acid gases (Hastelloy, Inconel, etc.) Heated probe tube in wet stack (saturated) conditions to help prevent corrosion Impingement shield on probe inlet to prevent clogging from wet particulate Demisters to knock down entrained water in sample prior to entering dilution orifice Probe accessibility for maintenance and service Stack clearances for probe installation and removal Temperature effects on the density of the flue gas minimized by the use of a heated orifice

32 Wet & Dry FGD CEMS Application CEMS Design Considerations Coal Fired Boiler FGD Scrubber General CEMS Design Sample Umbilical l Design Sample line routing and access. Keep in mind access for stack testers and maintenance personnel. Test Port ot Heated umbilical for low dilution ratios (higher moisture concentrations) Heated umbilical for low CO measurement applications in conjunction with stainless steel tubing

33 Wet & Dry FGD CEMS Application CEMS Design Considerations Coal Fired Boiler FGD Scrubber General CEMS Design Dilution Air Cleanup Design Plant air cleanup panel to condition air to instrument grade may be required Redundant dilution air cleanup for added system availability CO and trace gas scrubbers for removal of measured gases CO 2 Adsorbers & Trace Gas Scrubbers CO Scrubbers

Maintaining Continuous Emissions Monitoring Systems To Achieve High Reliability. a technical solution to meet every need

Maintaining Continuous Emissions Monitoring Systems To Achieve High Reliability. a technical solution to meet every need Maintaining Continuous Emissions Monitoring Systems To Achieve High Reliability a technical solution to meet every need Tim Kuiken Western Regional Sales Manager CEMTEK Environmental 3041 S. Orange Ave

More information

Continuous Emissions Monitoring Systems. Engineering & Design. For PetroChem Processes

Continuous Emissions Monitoring Systems. Engineering & Design. For PetroChem Processes Continuous Emissions Monitoring Systems Engineering & Design For PetroChem Processes a technical solution to meet every need Cemtek Environmental Inc. 3041 S. Orange Ave. Santa Ana, CA 92707 800-400-0200

More information

A Higher Standard of Monitoring Systems & Customer Service

A Higher Standard of Monitoring Systems & Customer Service A Higher Standard of Monitoring Systems & Customer Service Engineered Technical Solution to Meet Every Need. Cemtek Environmental, Inc. 3041 S. Orange Avenue Santa Ana, California 92707 USA 888.400.0200

More information

CEMS for Measurement of Ammonia, SO 3, and Low Level NOx

CEMS for Measurement of Ammonia, SO 3, and Low Level NOx CEMS for Measurement of Ammonia, SO 3, and Low Level NOx McIlvaine Company Hot Topic Hour Richard Himes Senior Project Manager rhimes@epri.com Chuck Dene Senior Project Manager cdene@epri.com October 22,

More information

CONTINUOUS EMISSION MONITORING SYSTEM. Copyright Adage Automation Pvt Limited

CONTINUOUS EMISSION MONITORING SYSTEM. Copyright Adage Automation Pvt Limited CONTINUOUS EMISSION MONITORING SYSTEM Copyright 2016 - Adage Automation Pvt Limited WHAT IS CEMS? A continuous emission monitoring system (CEMS) is the total equipment necessary for the determination of

More information

John Downs Environmental Manager, B&W PGG, KVB-Enertec Products. January 29, 2015

John Downs Environmental Manager, B&W PGG, KVB-Enertec Products. January 29, 2015 John Downs Environmental Manager, B&W PGG, KVB-Enertec Products January 29, 2015 Introduction What is a CEMS? Regulatory Drivers for CEMS Quality Assurance of CEMS Summary & Question A continuous emission

More information

Continuous Emissions Monitoring Systems. Engineering & Design. For PetroChem Processes. a technical solution to meet every need

Continuous Emissions Monitoring Systems. Engineering & Design. For PetroChem Processes. a technical solution to meet every need Continuous Emissions Monitoring Systems Engineering & Design For PetroChem Processes a technical solution to meet every need Cemtek Environmental Inc. 3041 S. Orange Ave. Santa Ana, CA 92707 800-400-0200

More information

TruePeak TDLS200. NH 3 Slip Measurement. <Document Number> Copyright Yokogawa Electric Corporation <date/time>

TruePeak TDLS200. NH 3 Slip Measurement. <Document Number> Copyright Yokogawa Electric Corporation <date/time> TruePeak TDLS200 NH 3 Slip Measurement One Background One Two Three Four Gas-Fired Installations The SCR control system must be able to perform in a range of conditions Flue gases from

More information

A global monitoring systems offering. A world of advantages. Thermo Scientific Continuous Emissions Monitoring Systems

A global monitoring systems offering. A world of advantages. Thermo Scientific Continuous Emissions Monitoring Systems A global monitoring systems offering. A world of advantages. Thermo Scientific Continuous Emissions Monitoring Systems Part of Thermo Fisher Scientific The complete solution Clean Air commitment. Since

More information

Cross-effects and total gas clean-up system lay-out

Cross-effects and total gas clean-up system lay-out Cross-effects and total gas clean-up system lay-out Gas clean-up for power plants and waste incinerators Effect of emission control on emissions and emission control for other species see: www.hut.fi/~rzevenho

More information

SCR Control Strategy and CEMS for an Ultra-Low NO x Emitter

SCR Control Strategy and CEMS for an Ultra-Low NO x Emitter SCR Control Strategy and CEMS for an Ultra-Low NO x Emitter Dale P. Evely, P.E. Harrison B. Manning Consulting Engineer Senior Engineer Instrumentation and Control Instrumentation and Control Southern

More information

: Industrial Boiler MACT: CEM Requirements. Dan Kietzer: SICK Process Automation

: Industrial Boiler MACT: CEM Requirements. Dan Kietzer: SICK Process Automation : Industrial Boiler MACT: CEM Requirements Dan Kietzer: SICK Process Automation : Overview: Boiler MACT : Testing Boiler MACT Testing and Monitoring Requirement - Initial compliance tests (PM, HCl, Mercury,

More information

Continuous Emissions Monitoring in Support of the Cement MACT

Continuous Emissions Monitoring in Support of the Cement MACT Continuous Emissions Monitoring in Support of the Cement MACT McIlvaine Webinar on Cement MACT March 30, 2011 Topics Covered Overview of Portland Cement MACT Mercury monitoring on cement kilns PM CEMS

More information

Combustion Control and Safety A comparison between Zirconium Oxide/Catalytic and Tunable Diode (TDL) Technologies Dr Stephen Firth / Rhys Jenkins

Combustion Control and Safety A comparison between Zirconium Oxide/Catalytic and Tunable Diode (TDL) Technologies Dr Stephen Firth / Rhys Jenkins Combustion Control and Safety A comparison between Zirconium Oxide/Catalytic and Tunable Diode (TDL) Technologies Dr Stephen Firth / Rhys Jenkins Agenda Introduction Combustion Theory / Practical Benefits

More information

Common CEMS RATA Failures and Risks. Paula Metz Alliance Source Testing, LLC Technical Services Assistant Manager

Common CEMS RATA Failures and Risks. Paula Metz Alliance Source Testing, LLC Technical Services Assistant Manager Common CEMS RATA Failures and Risks Paula Metz Alliance Source Testing, LLC Technical Services Assistant Manager Introduction Stack Testing is a labor and time intensive process and requires thorough planning

More information

Sampling Technology for Extractive CEMS & Maintenance Issues of CEMS Sanjeev Rai Perma Pure Aug 9, 2016

Sampling Technology for Extractive CEMS & Maintenance Issues of CEMS Sanjeev Rai Perma Pure Aug 9, 2016 Continuous Emission Monitoring System From Understanding to Implementation Sampling Technology for Extractive CEMS & Maintenance Issues of CEMS Sanjeev Rai Perma Pure Aug 9, 2016 INDEX Different Application

More information

WHITEPAPER: AMMONIA MEASUREMENT FOR COMBUSTION SOURCES

WHITEPAPER: AMMONIA MEASUREMENT FOR COMBUSTION SOURCES WHITEPAPER: AMMONIA MEASUREMENT FOR COMBUSTION SOURCES PREPARED BY: INSTITUTE OF CLEAN AIR COMPANIES EMISSIONS MEASUREMENT DIVISION June 2011 Copyright Institute of Clean Air Companies, Inc., 2011. All

More information

Online Infrared Flue Gas Analyzer Gasboard 3000

Online Infrared Flue Gas Analyzer Gasboard 3000 Online Infrared Flue Gas Analyzer Gasboard 3000 O 2 CO CO 2 SO 2 NO NO x Measurement Methods Proprietary Infrared NDIR Detectors - Micro-flow in ppm range: CO, NO, SO2 - Dual beam in % volume ranges: CO2

More information

Trace HCl measurements in coal-fired power plant emissions using Cavity Enhanced Laser Absorption Spectroscopy

Trace HCl measurements in coal-fired power plant emissions using Cavity Enhanced Laser Absorption Spectroscopy ABB MEASUREMENT & ANALYTICS WHITE PAPER Trace HCl measurements in coal-fired power plant emissions using Cavity Enhanced Laser Absorption Spectroscopy Cavity Enhanced (laser) Absorption Spectroscopy CEAS)

More information

Energy Production Systems Engineering

Energy Production Systems Engineering Welcome to Energy Production Systems Engineering USF Polytechnic Engineering tom@thomasblairpe.com Session 10: Environmental Controls Spring 2012 Plant Environmental Control Systems Power plant Environmental

More information

Fpollutant-free zero air for analytical

Fpollutant-free zero air for analytical Ambient Air Quality Monitoring System AQMS-100 Zero Air Generator PI AQMS-100 provides ultra pure Fpollutant-free zero air for analytical purpose. Remote monitoring and configuration can also be achieved

More information

Continous Emission Monitoring: Methods, Regulations and QA/QC. Anders Arvidsson, Opsis AB, Sweden

Continous Emission Monitoring: Methods, Regulations and QA/QC. Anders Arvidsson, Opsis AB, Sweden Continous Emission Monitoring: Methods, Regulations and QA/QC Anders Arvidsson, Opsis AB, Sweden OPSIS? OPSIS is a Swedish company which develops, manufactures and supplies total solutions for Ambient

More information

ABB Measurement & Analytics Monitoring cement plant stack emissions using FTIR

ABB Measurement & Analytics Monitoring cement plant stack emissions using FTIR White paper WP/ANALYTICAL/002 EN ABB Measurement & Analytics Monitoring cement plant stack emissions using FTIR ABB FTIR CEMS analyzer successfully monitors cement plant stack emissions in extensive field

More information

ABB Measurement & Analytics Trace HCl measurements in coal-fired power plant emissions using Cavity Enhanced Laser Absorption Spectroscopy

ABB Measurement & Analytics Trace HCl measurements in coal-fired power plant emissions using Cavity Enhanced Laser Absorption Spectroscopy White paper WP/ANALYTICAL/1 EN Rev. A ABB Measurement & Analytics Trace HCl measurements in coal-fired power plant emissions using Cavity Enhanced Laser Absorption Spectroscopy Cavity Enhanced (laser)

More information

PPC specializes in maximum efficiency air pollution control equipment using a variety of different

PPC specializes in maximum efficiency air pollution control equipment using a variety of different PPC specializes in maximum efficiency air pollution control equipment using a variety of different technologies. These include wet and dry electrostatic precipitator devices (ESP) for particulate control,

More information

Particulate CEMs for Wet and Dry FGD applications. By William Averdieck, Managing Director, PCME Ltd, UK

Particulate CEMs for Wet and Dry FGD applications. By William Averdieck, Managing Director, PCME Ltd, UK 1) Introduction Particulate CEMs for Wet and Dry FGD applications By William Averdieck, Managing Director, PCME Ltd, UK Williama@pcme.co.uk This paper overviews the challenges of monitoring particulate

More information

New Requirements for the Measurement of Ammonia Emissions

New Requirements for the Measurement of Ammonia Emissions New Requirements for the Measurement of Ammonia Emissions Dr. Berthold Andres Consulting für Emissions- und Prozessmesstechnik 63599 Biebergemünd, Hufeisenstrasse 9 Germany 1. Summary The first draft for

More information

PRODUCT CONFORMITY CERTIFICATE This is to certify that the

PRODUCT CONFORMITY CERTIFICATE This is to certify that the PRODUCT CONFORMITY CERTIFICATE This is to certify that the Babcock & Wilcox Model 2008-1 CEMS (EN 15267-3 Standard) & Babcock & Wilcox Stack Flow Monitor Model 110 manufactured by: Babcock & Wilcox Company

More information

CANADA UNISEARCH founded in 1980

CANADA UNISEARCH founded in 1980 CANADA UNISEARCH founded in 1980 Piergiorgio Viglino Sales and Service Manager Europe and the Middle East pviglino@unisearch-associates.com Tunable Diode Laser (TDL) Absorption Spectrometry LasIR TM TDL

More information

Measurement of Space-Heating Emissions. Prepared for:

Measurement of Space-Heating Emissions. Prepared for: Measurement of Space-Heating Emissions Prepared for: Dr. James F. Conner Air Quality Manager Fairbanks North Star Borough 809 Pioneer Road Fairbanks, AK 99701 Prepared by: OMNI-Test Laboratories, Inc.

More information

Field Test Program to Evaluate Mercury Emissions from Coal-Fired Facilities with SCR-FGD Systems

Field Test Program to Evaluate Mercury Emissions from Coal-Fired Facilities with SCR-FGD Systems Field Test Program to Evaluate Mercury Emissions from Coal-Fired Facilities with SCR-FGD Systems J. A. Withum, S. C. Tseng, J. E. Locke Forum 03: Multi-Pollutant Emission Controls & Strategies October

More information

Analysis systems. Analysis system for CO, Nox, O2, T. Analysis systems for CO, O2, T multiplexing, OPC

Analysis systems. Analysis system for CO, Nox, O2, T. Analysis systems for CO, O2, T multiplexing, OPC Analysis systems Analysis system for CO, Nox, O2, T Conditioned analysis system for the CO-NOx, O2, Temperature measure in flue gas methane boiler Composed of: Zirconia oxygen analyzer CO and NO NDIR infrared

More information

Gas Turbine Inlet Air Cooling System

Gas Turbine Inlet Air Cooling System Gas Turbine Inlet Air Cooling System Presented by Bob Omidvar Heavy Duty GT - Effects of Ambient Temp 110% 105% 100% 95% 90% 85% 80% 75% 0 5 10 15 20 25 30 35 40 45 GT Inlet Temp (deg C) Heat rate kj/kwh

More information

Stack Sampling. requires airflow through the sampling probe to be at the same rate as that flowing in the waste gas stream isokinetic

Stack Sampling. requires airflow through the sampling probe to be at the same rate as that flowing in the waste gas stream isokinetic Stack Sampling emissions associated with combustion, velocity and temperature may be much higher than ambient conditions - measure to correct to standard conditions Velocity data determined from pressure

More information

Sorbents Evaluation Testing Facilities. 95% removal efficiency or an emission standard of lbs/gw h by 2012, while

Sorbents Evaluation Testing Facilities. 95% removal efficiency or an emission standard of lbs/gw h by 2012, while Sorbents Evaluation Testing Facilities Several states have enacted Hg emission regulations that are more stringent than the CAMR milestones. For example, Massachusetts will require power plants to achieve

More information

Monitoring cement plant stack emissions using FTIR

Monitoring cement plant stack emissions using FTIR ABB MEASUREMENT & ANALYTICS WHITE PAPER Monitoring cement plant stack emissions using FTIR ABB FTIR CEMS analyzer successfully monitors cement plant stack emissions in extensive field study Measurement

More information

Catalytic Activated Ceramic Dust Filter a new technology for combined removal of dust, NOx, dioxin, VOCs and acids from off gases.

Catalytic Activated Ceramic Dust Filter a new technology for combined removal of dust, NOx, dioxin, VOCs and acids from off gases. Catalytic Activated Ceramic Dust Filter a new technology for combined removal of dust, NOx, dioxin, VOCs and acids from off gases. * Presenting author Peter Schoubye and Joakim Reimer Jensen *, Haldor

More information

Can your unit pass a Particulate Emission Compliance Test?

Can your unit pass a Particulate Emission Compliance Test? Source Emissions Testing and Emissions Specialists Can your unit pass a Particulate Emission Compliance Test? Kevin Crosby The Avogadro Group, LLC California - Oregon - Arizona McIlvaine Hot Topic Hour,

More information

Mercury Monitoring in a Cement Kiln

Mercury Monitoring in a Cement Kiln Application Note: HGCement_06.11 Mercury Monitoring in a Cement Kiln Anand Mamidipudi, Product Line Manager Thermo Fisher Scientific, 27 Forge Parkway, Franklin, MA 02038 Key Words: Mercury Hg Cement Kiln

More information

Process Analytics Using Quantum Cascade Laser

Process Analytics Using Quantum Cascade Laser Process Analytics Using Quantum Cascade Laser YT Koh Director Analyzers & Solutions Standards Certification Education & Training Publishing Conferences & Exhibits Presenter Koh Yee Tiong Yee Tiong (YT),

More information

Minimizing Ammonia Consumption in DeNOx Plants In situ Laser Gas Analyzer LDS 6 Monitors NH 3 Slip in Real-time

Minimizing Ammonia Consumption in DeNOx Plants In situ Laser Gas Analyzer LDS 6 Monitors NH 3 Slip in Real-time Minimizing Ammonia Consumption in DeNOx Plants In situ Laser Gas Analyzer LDS 6 Monitors NH 3 Slip in Real-time Flue gas denitrification Combustion processes result in emissions that can be harmful to

More information

Chapter 9 Emission Measurement, Monitoring & Reporting

Chapter 9 Emission Measurement, Monitoring & Reporting Chapter 9 Emission Measurement, Monitoring & Reporting Editor s Note: Chapter 9 Emissions Measurement and Reporting - is most of Chapter 13 from the 2000 version of APTI 418 written by James A. Jahnke..

More information

Acid Gas Control Systems. Spray-Dry Scrubbers and Dry Injection Systems. United McGill products. a McGill AirClean product

Acid Gas Control Systems. Spray-Dry Scrubbers and Dry Injection Systems. United McGill products. a McGill AirClean product United McGill products a McGill AirClean product Acid Gas Control Systems Spray-Dry Scrubbers and Dry Injection Systems An enterprise of United McGill Corporation Family owned and operated since 1951 2011

More information

TUV Certified FTIR CEM and Ultra Low Level HCl CEM for Combustion Facilities

TUV Certified FTIR CEM and Ultra Low Level HCl CEM for Combustion Facilities TUV Certified FTIR CEM and Ultra Low Level HCl CEM for Combustion Facilities CEM 2014 May 15-17, 2014 Istanbul, Turkey Peter G. Zemek MultiGas FT-IR Automated HCl CEM Systems MKS Instruments On-Line Product

More information

Analyzer Module Wet Chemiluminescence Detection (WCLD)

Analyzer Module Wet Chemiluminescence Detection (WCLD) Product Data Sheet PDS 103-670.A01 October, 2003 NGA 2000 Heated NO/NO x Analyzer Module Wet Chemiluminescence Detection (WCLD) Heated sample handling module for hot/ wet gas samples Eliminates loss of

More information

SCR for NO x Control in Coal-fired Power Plants

SCR for NO x Control in Coal-fired Power Plants SCR for NO x Control in Coal-fired Power Plants The McIlvaine Company April 7, 2011 Hot Topic Hour on New FGD and DeNOx Approaches Ken Jeffers Sr Applications Engineer SCR Basics Quick Review Flue Gas:

More information

PORTABLE FLUE GAS ANALYZER

PORTABLE FLUE GAS ANALYZER PORTABLE FLUE GAS ANALYZER SAFETY PROCESS INDUSTRY LABORATORY & RESEARCH What is Flue Gas? Flue Gas Flue gas or Exhaust gas is emitted as a result of the combustion of fuels such as natural gas, gasoline/petrol,

More information

Portable Infrared Flue Gas Analyzer Gasboard 3800P

Portable Infrared Flue Gas Analyzer Gasboard 3800P Portable Infrared Flue Gas Analyzer Gasboard 3800P Hubei Cubic-Ruiyi Instrument Co.,Ltd Add:Fenghuang No.3 Road Fenghuang Industrial Park Eastlake Hi-tech Development Zone Wuhan 430205, China Tel: 86-27-81628831

More information

POWER PLANT AIR QUALITY CONTROL and FLY ASH QUALITY & AVAILABILITY

POWER PLANT AIR QUALITY CONTROL and FLY ASH QUALITY & AVAILABILITY POWER PLANT AIR QUALITY CONTROL and FLY ASH QUALITY & AVAILABILITY Fred Gustin Kansas City Power & Light David Rylance Kansas City Fly Ash AWMA January 18, 2017 What Major Pollutants are Controlled? Particulates

More information

Technical Guidance Note (Monitoring) Medium Combustion Plant Directive and Generator Controls: monitoring point source emissions

Technical Guidance Note (Monitoring) Medium Combustion Plant Directive and Generator Controls: monitoring point source emissions Technical Guidance Note (Monitoring) M5 Medium Combustion Plant Directive and Generator Controls: monitoring point source emissions Environment Agency XXXX 2018 Version X Draft for consultation Foreword

More information

Worldwide Pollution Control Association

Worldwide Pollution Control Association Worldwide Pollution Control Association IL Regional Technical Seminar September 13-15,2011 Visit our website at www.wpca.info Using Dry Sorbent Injection to Meet the Utility MACT Curt Biehn Mississippi

More information

GAS ANALYZERS. Digital Manometer

GAS ANALYZERS. Digital Manometer GAS ANALYZERS Digital Manometer 5 Gas Handheld AmPro 2000 O2, CO, NO + NO2 and SO2 or H2S or High CO THE MOST POWERFUL HANDHELD MULTIGAS ANALYZER FOR INDUSTRIAL COMBUSTIONS, EMISSION AND PROCESS MONITORING

More information

ASI MODEL DM 100 SERIES DILUTING MODULES

ASI MODEL DM 100 SERIES DILUTING MODULES ASI MODEL DM 100 SERIES DILUTING MODULES The ASI Model DM 100 Series Diluting Modules have been developed to meet the requirements of some of our more specialized applications, where our standard in situ

More information

Standard Continuous Emissions Monitoring System (CEMS)

Standard Continuous Emissions Monitoring System (CEMS) Scan for more information on CEMS Specification Sheet Continuous Emissions Monitoring System (CEMS) Photo may not represent the actual system supplied. www.usa.siemens.com/cems-std Overview The CEMS is

More information

EPA vs. EN standards

EPA vs. EN standards EPA vs. EN standards 1 Tasks Goal: Determination of differences and similarities of EN and EPA to get a guideline what to change to be consistent within the EN CEMS framework Text comparison Approx. 1

More information

Accurate determination of trace elements emissions using AFS. Dr Warren Corns. Coal Research Forum 2016 PSA. Slide 1

Accurate determination of trace elements emissions using AFS. Dr Warren Corns. Coal Research Forum 2016 PSA. Slide 1 Accurate determination of trace elements emissions using AFS Dr Warren Corns Slide 1 Coal Research Forum 2016 Experience in the Trace Element Emissions Slide 2 Numerous Hg in stack gas analysers worldwide

More information

Industrial Gas Analyzers in Applications Information

Industrial Gas Analyzers in Applications Information Industrial Gas Analyzers in Applications Information Engine and Diesel Testing www.eurotron.co.kr Thousands of internal combustion engines are located throughout the world. They range in size from small

More information

Diode laser analyser LS4000 Ammonia slip measurement for DeNOx process

Diode laser analyser LS4000 Ammonia slip measurement for DeNOx process ABB MEASUREMENT & ANALYTICS APPLICATION NOTE Diode laser analyser LS4000 Ammonia slip measurement for DeNOx process Optimize efficiency of denitrification process in DeNOx unit. Reduce downstream problems,

More information

Multipoint Probes to Mitigate Stratification CEMTEK Users Meeting. September 28 th, 2016

Multipoint Probes to Mitigate Stratification CEMTEK Users Meeting. September 28 th, 2016 Multipoint Probes to Mitigate Stratification CEMTEK Users Meeting September 28 th, 2016 This image cannot currently be displayed. M&C supplies World Class Custom Designed Probes, Manifold Systems, Sample

More information

Advances in NOx Compliance Testing with Portable Electrochemical Analyzers

Advances in NOx Compliance Testing with Portable Electrochemical Analyzers Advances in NOx Compliance Testing with Portable Electrochemical Analyzers LADCO Workshop: Emission Control and Measurement Technology for Industrial Sources March 24-25, 2009 Craig McKim, Emission Division

More information

W P C A. Worldwide Pollution Control Association. WPCA-Duke Energy FF/HAPS Seminar October 12-13, Visit our website at

W P C A. Worldwide Pollution Control Association. WPCA-Duke Energy FF/HAPS Seminar October 12-13, Visit our website at Worldwide Pollution Control Association WPCA-Duke Energy FF/HAPS Seminar October 12-13, 2011 All presentations posted on this website are copyrighted by the Worldwide Pollution Control Association (WPCA).

More information

Mercury Monitoring Technologies and Detection Principles

Mercury Monitoring Technologies and Detection Principles Mercury Monitoring Technologies and Detection Principles a technical solution to meet every need CEMTEK Environmental Inc. 3041 S. Orange Ave. Santa Ana, CA 92707 800-400-0200 www.cemteks.com Mercury Fountain

More information

Performance Tests & RATAs. Our Mission: To protect and improve the health and environment of all Kansans

Performance Tests & RATAs. Our Mission: To protect and improve the health and environment of all Kansans Performance Tests & RATAs What is a Performance Test? Commonly referred to as a stack test, trial burn or performance test A performance test is used to: Measure the amount of regulated pollutants that

More information

Continuous Emissions Monitoring (CEMS) Package With NGA 2000 Analyzers

Continuous Emissions Monitoring (CEMS) Package With NGA 2000 Analyzers Product Data Sheet PDS 103-101M.A01 June, 2004 GMP 1000M Continuous Emissions Monitoring (CEMS) Package With NGA 2000 Analyzers Packaged approach to measuring up to five gases plus opacity Measurement

More information

Environmental Equipment, Inc. IMR 5000 Continuous Flue Gas Monitoring System IMR 5000

Environmental Equipment, Inc. IMR 5000 Continuous Flue Gas Monitoring System IMR 5000 IMR 5000 Continuous Flue Gas Monitoring System The IMR 5000 is state-of-the-art continuous flue-gas monitoring system, and is designed for a wide variety of flue-gas monitoring applications. The IMR 5000

More information

CEMENT PLANT ENVIRONMENTAL TECHNOLOGY FOR ACHIEVING HIGH SO 2 REMOVAL

CEMENT PLANT ENVIRONMENTAL TECHNOLOGY FOR ACHIEVING HIGH SO 2 REMOVAL CEMENT PLANT ENVIRONMENTAL TECHNOLOGY FOR ACHIEVING HIGH SO 2 REMOVAL Sara Safariyeganeh sara.safariyeganeh@mecsglobal.com Cary Joe Lovett, PE joe.lovett@holcim.com Abstract - The EPA has adopted revised

More information

Mercury CEMS Sample Line Temperature Reduction Study

Mercury CEMS Sample Line Temperature Reduction Study Mercury CEMS Sample Line Temperature Reduction Study Turn Down the Heat Spectrum Systems: Sean Myrick and Reggie Davis Thermo Fisher Scientific: Jeremy Whorton Combined Study, Conducted 2011 Presented

More information

Worldwide Pollution Control Association

Worldwide Pollution Control Association Worldwide Pollution Control Association IL Regional Technical Seminar September 13-15,2011 Visit our website at www.wpca.info Utility MACT PM Control with WESP Technology Buzz Reynolds VP Wet ESP Siemens

More information

Process Analytical and Continuous Emissions Monitoring Systems

Process Analytical and Continuous Emissions Monitoring Systems Process & Emissions Monitoring Solutions pentair environmental systems ISSUED MARCH 2013 Process Analytical and Continuous Emissions Monitoring Systems Goyen is a division of Pentair, which services the

More information

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE PRODUCT NFORMITY CERTIFICATE This is to certify that the MCS100 E CD Multi-Component Analyser manufactured by: SICK MAIHAK GmbH Dr Zimmermann Straße 18 88709 Meersburg Germany has been assessed by Sira

More information

Overview of Mercury Monitoring Technologies and Regulatory Requirements

Overview of Mercury Monitoring Technologies and Regulatory Requirements Overview of Mercury Monitoring Technologies and Regulatory Requirements ICAC/MARAMA Mercury CEMS Webinar Carolyn Slaughter E-mail: cslaughter@icac.com July 26, 2011 1 ICAC S Mission ICAC gives the air

More information

Control Device Technology

Control Device Technology Control Device Technology A quick summary of various control measures and important monitoring characteristics Peter Westlin, EPA, OAQPS Example Control Measures and Monitoring Approaches Organics gases

More information

Advanced AQCS for Oxy-fuel Combustion System; Controlling Mercury & SO3

Advanced AQCS for Oxy-fuel Combustion System; Controlling Mercury & SO3 Special Workshop on SO2, SO3, Hg and Boiler Corrosion Issue Under Oxyfuel Combustion Condition Advanced AQCS for Oxy-fuel Combustion System; Controlling Mercury & SO3 Babcock-Hitachi K.K. Hirofumi Kikkawa

More information

Drying of High-Moisture Coals For Power Production & Gasification

Drying of High-Moisture Coals For Power Production & Gasification 350 SMC Drive Somerset, WI 54025 USA Phone: (715) 247-3433 Fax: (715) 247-3438 Drying of High-Moisture Coals For Power Production & Gasification Given the global abundance of coal and its importance in

More information

Worldwide Pollution Control Association

Worldwide Pollution Control Association Worldwide Pollution Control Association IL Regional Technical Seminar September 13-15,2011 Visit our website at www.wpca.info Optimizing Gas and Particulate Flows to Minimize NO x, Hg, and SO 3 WPCA Illinois

More information

PM Compliance Options for MACT and MATS Rules. Ed McCall PCME

PM Compliance Options for MACT and MATS Rules. Ed McCall PCME PM Compliance Options for MACT and MATS Rules Ed McCall PCME 1 First Some Definitions: PM- CEM, PM-CPMS and BLDs PM-CEM (PM- Continuous Emission Monitor) PM-CPMS (PM-Continuous Parametric Monitoring System)

More information

Mercury and SO3 Mitigation Issues for Scrubber Technology

Mercury and SO3 Mitigation Issues for Scrubber Technology Mercury and SO3 Mitigation Issues for Scrubber Technology W. Scott Hinton, Ph.D., P.E. Southern Research Institute WPCA/Ameren Particulate Seminar May 31 to June 1, 2006 SO3 Behavior in Scrubbers The Problem

More information

Process Optimization & Plant Safety

Process Optimization & Plant Safety Engineering Solution for Cement Industry Process Optimization & Plant Safety By : Teoh Wen Han Venue : Forest Hill Resort, Saraburi, Thailand Date : 12 September 2006 Presentation Contents Optimized Integrated

More information

Coal Fired Boiler Optimization and the Impact on Emission Control Devices

Coal Fired Boiler Optimization and the Impact on Emission Control Devices Coal Fired Boiler Optimization and the Impact on Emission Control Devices Shawn Cochran Danny Storm Typical Emissions Controlled via Backend Equipment Particulate matter Electric Static Precipitator (ESP),

More information

Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard

Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard Introduction SRU s (Sulfur Recovery Units) are critical pieces of equipment in refineries and gas plants. SRUs remove sulfur compounds from certain

More information

VOLATILE ORGANIC COMPOUNDS

VOLATILE ORGANIC COMPOUNDS DTE Energy' COMPLANCE TEST REPORT for VOLATLE ORGANC COMPOUNDS UNT 3- FGD Stack Monroe Power Plant Monroe, Michigan Prepared By Environmental Management & Resources Environmental Field Services Group DTE

More information

Gas Flow How to Improve It to Enhance ESP, Boiler, FGD, SCR, SNCR Performance

Gas Flow How to Improve It to Enhance ESP, Boiler, FGD, SCR, SNCR Performance Gas Flow How to Improve It to Enhance ESP, Boiler, FGD, SCR, SNCR Performance WPCA Seminar Duke Energy September 3, 2008 Robert Mudry, P.E. Vice President Engineering rmudry@airflowsciences.com Outline

More information

Worldwide Pollution Control Association

Worldwide Pollution Control Association Worldwide Pollution Control Association WPCA- Southern Company Mercury Seminar October 30-31, 2012 All presentations posted on this website are copyrighted by the Worldwide Pollution Control Association

More information

EMO August 1, Bobby I.T. Chen Client Program Manager

EMO August 1, Bobby I.T. Chen Client Program Manager EMO August 1, 2013 Bobby I.T. Chen Client Program Manager MATS Overview Subcategory Total Filterable Particulate Matter (PM) Hydrogen Chloride (HCl) Mercury (Hg) Existing coal fired unit designed for coal

More information

Difficult CEMS Applications at Refineries & Chemical Plants

Difficult CEMS Applications at Refineries & Chemical Plants Difficult CEMS Applications at Refineries & Chemical Plants Bart Leininger, P.E. Principal Ashworth Leininger Group Camarillo, CA 4/3/18 Page 1 Objectives Discussion of CEMS and Process Measurement Sample

More information

Comparison Continuous Emission Monitoring Techniques

Comparison Continuous Emission Monitoring Techniques PRODUCT DATASHEET: Comparison Continuous Comparison Continuous Emission Monitoring Techniques Overview The requirements for continuous emission monitors has changed significantly over the last 30 years.

More information

This document is a preview generated by EVS

This document is a preview generated by EVS INTERNATIONAL STANDARD ISO 13199 First edition 2012-10-15 Stationary source emissions Determination of total volatile organic compounds (TVOCs) in waste gases from non-combustion processes Nondispersive

More information

The Proper Mechanism for Field Validating Moisture Analyzers. GE Measurement & Sensing GE Oil & Gas

The Proper Mechanism for Field Validating Moisture Analyzers. GE Measurement & Sensing GE Oil & Gas The Proper Mechanism for Field Validating Moisture Analyzers Frank Gerritse Narge Sparages GE Measurement & Sensing GE Oil & Gas Abstract Field verification of moisture analyzer calibrations mitigates

More information

Continuous Mercury Monitoring at Cement Plant

Continuous Mercury Monitoring at Cement Plant 21.07.2014 Continuous Mercury Monitoring at Cement Plant Background The production of cement klinker and lime in rotary kilns is responsible for 10.7% of mercury emissions to air (3,337 kg) according to

More information

Worldwide Pollution Control Association. August 3-4, 2010

Worldwide Pollution Control Association. August 3-4, 2010 Worldwide Pollution Control Association IL Regional Technical Seminar August 3-4, 2010 Visit our website at www.wpca.infowpca An Unbiased Comparison of FGD Technologies: Wet, Spray Dry and CDS WPCA Conference

More information

Environmental Policies. Bruce Rising Siemens Westinghouse

Environmental Policies. Bruce Rising Siemens Westinghouse Environmental Policies Bruce Rising Siemens Westinghouse 12 Mar 2001 Overview Gas turbine technology will continue to be play a critical role in US energy needs. Air quality improvements have been substantial,

More information

Plasma-based cleaning of exhaust gases of combustion Plasma based cleaning of exhaust gases of combustion(wp4)

Plasma-based cleaning of exhaust gases of combustion Plasma based cleaning of exhaust gases of combustion(wp4) Plasma-based cleaning of exhaust gases of combustion Plasma based cleaning of exhaust gases of combustion(wp4) Eugen Stamate, Cornelia Iremiea, Technical University of Denmark, Denmark Indrek Jõgi, University

More information

Tunable Diode Laser Technology. Direct Adsorbtion

Tunable Diode Laser Technology. Direct Adsorbtion ISA Oct 21, 2014 Tunable Diode Laser Technology Direct Adsorbtion Ron Eddleman AAS Regional Sales Manager 1 Presentation Overview TDL Basics-How does it work What can be measured Types of installations

More information

Compliance Monitoring Using Continuous Emissions Monitoring Systems (CEMS)

Compliance Monitoring Using Continuous Emissions Monitoring Systems (CEMS) EAD-EQ-PCE-SOP-08 Signature on Original Environment Quality Sector * Corporate Management Representative Secretary General Originated By Reviewed By Approved By * Refer to SG Circular S.G/C-08/12 Concerning

More information

Analysis campaign for measurement of oxy-combustion flue gas from Coal Fired Plants

Analysis campaign for measurement of oxy-combustion flue gas from Coal Fired Plants Analysis campaign for measurement of oxy-combustion flue gas from Coal Fired Plants 15 May 2014 Morgane Rivière, Daniel Missault, Patrick Mauvais, Samuel Daeden, Grégoire Béasse, Claire Bourhy-Weber, Jean-Marc

More information

Guidance for Portable Electrochemical Analyzer Testing Used for Compliance Monitoring

Guidance for Portable Electrochemical Analyzer Testing Used for Compliance Monitoring Guidance for Portable Electrochemical Analyzer Testing Used for Compliance Monitoring Section I. Introduction DEQ s Air Quality Division administers the provisions of 40 CFR Part 70 as well as the minor

More information

natcom burner solutions Advanced burner technology for stringent emissions requirements

natcom burner solutions Advanced burner technology for stringent emissions requirements natcom burner solutions Advanced burner technology for stringent emissions requirements The benchmark of the industry Our Technological Edge HyperMix TM technology for ultra-low NOx and CO with compact

More information

State of the Art (SOTA) Manual for Stationary Gas Turbines

State of the Art (SOTA) Manual for Stationary Gas Turbines State of the Art (SOTA) Manual for Stationary Gas Turbines Original Date: July 1997 Revision Date: November 1999 State of New Jersey Department of Environmental Protection Air Quality Permitting Program

More information

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE PRODUCT NFORMITY CERTIFICATE This is to certify that the PG-250 Portable Gas Analyser Pre-conditioner PS200 manufactured by: Horiba Limited Miyanohigashi Kisshoin Minami-Ku Kyoto Japan has been assessed

More information