EFFECT OF PLUG REMOVAL ON LOAD TRANSFER IN PLUGGED OPEN ENDED PILE BEHAVIOR

Size: px
Start display at page:

Download "EFFECT OF PLUG REMOVAL ON LOAD TRANSFER IN PLUGGED OPEN ENDED PILE BEHAVIOR"

Transcription

1 International Journal of Civil Engineering and Technology (IJCIET) Volume 7, Issue 5, September-October 2016, pp , Article ID: IJCIET_07_05_015 Available online at ISSN Print: and ISSN Online: IAEME Publication EFFECT OF PLUG REMOVAL ON LOAD TRANSFER IN PLUGGED OPEN ENDED PILE BEHAVIOR Mohammed Y. Fattah Professor, Building and Construction Engineering Department, University of Technology, Baghdad, Iraq. Nahla M. Salim Assistant Professor, Building and Construction Engineering Department, University of Technology, Baghdad, Iraq. Asaad M.B. Al-Gharrawi Assistant Lecturer, Civil Engineering Department, University of Kufa, Iraq. ABSTRACT The experimental tests contain 36 tests carried out on single piles. All tubular piles tested by using the poorly graded sand from the southern city of Karbala in Iraq. The sand was prepared at three different densities using a raining technique. Different parameters are considered such as method of installation, relative density, removal of soil plug with respect to length of plug and pile length to diameter ratio. To simulate the pile load test in the field, the driving and pressing system for pile installation were manufactured. Strain gauges are used to separate skin friction with two components from and resistance bearing. The soil plug is removed by using a new device which is manufactured to remove the soil column inside open pipe piles group during driven and pressed device. The principle of soil plug removal depends on suction of sand inside pile. It was concluded that the removal of soil plug from piles will cause a reduction in pile load carrying capacity due to elimination of two components, internal friction and the confining in end bearing zone. The maximum reduction occurred in the dense state of soil with as a percentage of about 61.5%. The sand column length increases with the progressing of the installation pressure when pressing method is used, but in driven piles, there is no systematic trend of the sand column length generated in the piles. Long of piles have a higher probability of plugging and plugging penchant is also higher in dense and dilatant soils. Keywords: Pipe pile, open-ended, fully plugged, plug removal, friction, end bearing. Cite this Article: Mohammed Y. Fattah, Nahla M. Salim and Asaad M.B. Al-Gharrawi, Effect of Plug Removal on Load Transfer in Plugged Open Ended Pile Behavior. International Journal of Civil Engineering and Technology, 7(5), 2016, pp editor@iaeme.com

2 Mohammed Y. Fattah, Nahla M. Salim and Asaad M.B. Al-Gharrawi 1. INTRODUCTION Normally, vertical piles are used to carry compression loads from superstructures such as buildings, bridges, etc. The piles are used in groups joined together by pile caps. The loads carried by the piles are transferred to the adjacent soil. If all the loads coming on the tops of piles are transferred to the tips, such piles are called end-bearing or point-bearing piles. However, if all the load is transferred to the soil along the length of the pile such piles are called friction piles. If, in the course of driving a pile into granular soils, the soil around the pile gets compacted, such piles are called compaction piles. Small-displacement piles are either solid (e.g. steel H-piles) or hollow (open-ended tubular piles) with a relatively low cross-sectional area. This type of pile is usually installed by percussion method. However, a soil plug may be formed during driving, particularly with tubular piles, and periodic drilling out may be necessary to reduce the driving resistance. A soil plug can create a greater driving resistance than a closed end, because of damping on the inner-side of the pile. The soil inside an open-ended pile may form a plug during the driving process, preventing new soil from entering at the toe, referred to as soil plugging. Soil plugging changes the driving characteristics of the open-ended pile to that of a closed-ended pile, often accompanied by increased driving resistance. It follows that if the plugging behavior of the pile is not correctly understood, the result is either that unnecessarily powerful and costly hammers are used because of high predicted driving resistance or that the pile plugs (Karlowskis, 2014). The behavior of open-ended piles is more complex, with a response generally intermediate between that of non-displacement and displacement piles. As an open-ended pile is driven into the soil, a soil column (or soil plug) forms inside the pile. The length of this plug may be equal to or less than the pile driving depth. If it is the same, the pile has been driven in a fully coring or unplugged mode throughout. If driving takes place in a partially or fully plugged mode, at least during part of the way, the length of the soil plug within the pile will be less than that of the pile. It may be possible to observe all three driving modes (fully coring, partially plugged or fully plugged) during the driving of a single pile (Paikowski et al., 1989). The main objectives of this work are to offer a better realization regarding the performance of soils and pipe pile group under vertical loading with soil plug, and to provide valuable geotechnical data and parameters necessary for the numerical simulations and foundation design. Paik and Salgado (2003) stated that during the driving of open-ended pipe piles, some amount of soil will initially enter into the hollow pipe. Depending on the soil state (dense or loose) and type (fine-grained or coarse grained), diameter and length of pile, and the driving technique, the soil inside the pile may or may not allow further entry of soil into the pipe. If soil enters the pipe throughout the driving process, driving is said to take place in a fully coring mode and the behavior is more like that of a non-displacement pile. However, if the soil forms a plug at the pile base that does not allow further entry of soil, then driving is said to be done in a fully plugged mode. Shijhait (2013) and Fattah and Al-Soudani (2016a) studiedthe effect of different parameters such as pile diameter to length ratio, type of installation in sand of different densities on the bearing capacity of closed and open-ended piles. Removal of plug was dense in three stages (50%, 75% and 100%) with respect to length of plug. The total number of 84 model pile tests were carried out to assess the effect of soil plug on the model pile capacity. The piles were embedded in sand of different densities with different lengths of piles and types of pile ends. Piles with circular cross section are tested under the effect of vertical static compression load.itwas concluded that the percentage of reduction in pile load capacity for open ended pile increases with increase of the length of removal of the soil plug and increase of sand density and The pile reached a fully plugged state (for which IFR would be equal to zero) for pressed pile in loose and medium sand and partially plugged (IFR = 10%) in dense sand. For driven pile, the IFR is about 30% in loose sand, 20% in medium sand and 30% in dense sand. Fattah and Al-Soudani (2016b) investigated that the changes in the soil plug length and incremental filling ratio IFR with the penetration depth during pile driving and showed that the open-ended piles are partially plugged from the outset of the pile driving. The pile reached a fully plugged state for pressed piles in loose editor@iaeme.com

3 Effect of Plug Removal on Load Transfer in Plugged Open Ended Pile Behavior and medium sand and partially plugged (IFR = 10%) in dense sand. For driven piles, the IFR is about 30% in loose sand, 20% in medium sand, and 30% in dense sand. The pile load capacity increases with increases in the length of the plug length ratio PLR.The rate of increase in the value of the pile load capacity with PLR is greater in dense sand than in medium and loose sand. The objective of this study is carrying out experimental laboratory models for closed and open pipe pile, with plugged and unplugged case, for different cases including investigation and auditing of load settlement results, demonstration of internal and external friction components, and isolation of end bearing and total friction to know which of them is most influential on plug formation. 2. EXPERIMENTAL WORK AND MATERIALS The soil used in the research was brought from a site at the center of Karbala city in Iraq. The soil is classified as SP type (Poorly graded clean sand). Standard experiments were performed to determine the physical of the sand. The properties details are listed in Table 1. Laboratory tests carried out on soil used included the grain size distribution, specific gravity, direct shear test, and maximum and minimum dry unit weights. Table 1 Chemical and physical properties of sand. Physical properties Value Specification D 60,(mm) 0.95 D 30,(mm) 0.63 D 10,(mm) 0.33 Gravel (%) 0 ASTM D Sand (%) 95.8 ASTM D Silt and caly (%) 4.2 ASTM D Coefficient of uniformity (Cu) 2.88 Coefficient of curvature (Cc) 1.27 Specific gravity (Gs) 2.65 ASTM D Maximum dry unit weight (kn/m 3 ) 18.8 ASTM D Minimum dry unit weight (kn/m 3 ) 15.1 ASTM D Maximum void ratio (e max. ) 0.73 Minimum void ratio (e min. ) 0.42 Direct shear box experiment was performed according to ASTMD The direct shear box experiment has many particle sizes to boxsize Demands when preparing specimens for experiment. The minimum specimen width should not be less than 10 times the maximum particle size diameter and the minimum initial specimen thickness should not be less than six times the maximum particle diameter. The values of (φ) for loose, medium and dense sands are 31 o, 36 o and 40 o, respectively. The relative densities for loose, medium and dense sand were 20%, 45% and 75%, respectively. 3. MODEL SETUP FORMULATION To simulate the pile load experiment in the area, is useda new apparatus which manufactured by Shighait (2013) and modified in this work. It consists of the following parts: Steel container, steel base, steel loading frame, axial loading system, raining frame, impact hammer device, mechanical jack, load cell, digital weighing indicator, gear box, AC Drive (speed regulator), and pile driving or pressing system installation. The following parts are also included: Soil plugs removal and measurement system editor@iaeme.com

4 Mohammed Y. Fattah, Nahla M. Salim and Asaad M.B. Al-Gharrawi Strain gauges. Data logger. Linear variable differential transformer ( LVDT ). Digital dial gauges The steel container has dimensions of 750 mm in length, 750 mm in width, and 750 m in height. It is made of five separated parts, one for the base and the others for the four sides. Each container part was made of 4 mm thick steel plate. At the internal sides of the container, a steel bar was welded along three sides with 1 cm 2 cross sectional area and the front side was kept free. These shafts are welded each (100 mm) from the container bottom. Steel plate (740mm 740 mm) with 8 mm thickness movable plate at any specific height was designed; it is inserted inside the container and put on the welded bar and rested on it. This arrangement designed allows changing the height of soil bed that is being used. A steel base was designed for this study to support the container and the loading frame weight. The box is rested on two channels with the ability of lateral movement. A steel loading frame was manufactured to support the gear box motor, axial loading system and mechanical jack, as shown in Figure 1. The load is submitted through a mechanical jack joint by a gear box motor and AC drive (speed regulator), which in turn controls the speed of the gear box motor as shown in Figure 2. The maximum load that can be submitted is1 ton. The loading rate is kept constant at 1 mm/min as recommended by ASTM D The model has become after development possible to move in horizontal and vertical directionsto a pile group, while the original model was move only in one direction which is perpendicular to the cross section of piles, and so one can make sure that the load is in the middle of the pile system and there is no evidence of any eccentricity. Figure 1 Steel loading frame and axial loading system editor@iaeme.com

5 Effect of Plug Removal on Load Transfer in Plugged Open Ended Pile Behavior 4. SAND RAINING FRAME The raining frame consists of two columns with changeable height. It was made to achieve any desired elevation. The frame height change is done by holes with equidistance steps (15 cm). It is joined from top and bottom to the column with two to 4joints beams together and these beams are bolted at their ends. To support the U-section beams, the two beams in the longitudinal direction have (U-section) and the other beams are used. Another beam was designed as a roller, which are rests on the longitudinal beams to move along these beams. This (rolled-beam) is jointed from the bottom with another beam, it is supported with screw and it can be moved horizontally along with the beam; this beam was designed to carry the cone that is used to pour the sand. The raining frame is illustrated in Figure 2. This raining frame configuration helps get a uniform density by controlling the height of fall. The rolled-beam and the screw which is jointed with the cone to ensure each particle drop at equal height and uniform intensity. A mesh piece (the aperture diameter is 10 mm) is put inside the cone to reduce the effect of the particles (Shighait 2013). To control the fall height, additional tubular elongations at the cone end were usedby using adapted tubes. Figure 2 Raining frame used for controlling sand density. 5. PILE DRIVING PRESSING SYSTEM The piles setup system consists of a base plate with dimensions of (850 mm 200 mm) and 4 mm in thickness. This plate includes nine holes (31 mm) in diameter and the spacing between holes is (91 mm), these holes are considered as focus place for the piles to penetrate the soil in the box. To support the two beams that designed from stainless steel the two tube columns with (28 mm) diameter are fixed vertically. The main part in the driving hammer is the aluminum rod, it contains steel helmet in the rod head and steel cylinder, which is used as a base for dropping the hammer weight. The steel helmet was designed with various holes that are suitable for all model pile sizes used in the experiments. These grooves are designed to ensure the piles are as fixed as possible to reserve the vertical direction for penetration of pile without tilting through the driving process, and these parts are shown in Figure 3. Mechanical jack is used for pressing pile into the soil at a constant rate. This jack is fixed to the pile during installation system, and these parts are shown in Figure editor@iaeme.com

6 Mohammed Y. Fattah, Nahla M. Salim and Asaad M.B. Al-Gharrawi The hammer masses used in the experiments are circular in shape and formed from steel material. They have holes in the center to enable lifting and lowering along the hammer rod. The hammer mass which is lifted to a specified height (220 mm) by means of half- plastic plate with handle is fixed to small steel. Figure 3 Pile group system installation. 6. SOIL PLUGS REMOVAL AND MEASUREMENT SYSTEM This study is based on the system of cleaning pile raise plug. The mechanism is based on pulling out of sand from inside the pile after the completion of the pressure or driven piles. This system consists of motor with specifications following input operating vacuum (675mm Hg) and output-air flow (26 LPM ) and voltage v, AC 50 Hz connected to the flask to collect sand banter from inside the pile and then measuring the sand column height inside the pile, or a pile group. The instrument is relying on the withdrawal of sand and measurement system rod which consists of aluminum diameter 1.5 mm with different lengths based on the lengths of the pile that has been relegated in the sand as it was the work of signals every 10 mm to measure the length of the sand column after the clouds to find out the sand size that has been removed from inside the pile. 7. STRAIN GAUGE TECHNIQUE When a material is stretched (or compressed), corresponding inside stress generates by use the force. This stress in turn generates a proportional tensile strain (or compressive strain) that deforms the a trial by L+ L (or L- L), where L is the original material length and L is the length change. When this happens, the ratio of L to L is called strain. There are a many ways of measuring strain mechanically and electrically, but the vast majority of stress measurement is carried out using strain gauges because of their superior measurement features. 8. PIPE PILE PROPERTIES Regarding the physical properties of the adopted piles' sections, piles were experimented as per ASTM E8 with the collaboration of the Central Organization for Standardization and Quality Control. Four aluminum pipe pile samples have been taken randomly and experimented then the average value has been reported for each property as shown in Table editor@iaeme.com

7 Effect of Plug Removal on Load Transfer in Plugged Open Ended Pile Behavior Experiment Table 2 Aluminum pipe pile properties. Sample B1 Sample B2 Results Sample B3 Sample B4 Tensile strength (N/mm 2 ) Yeild strength (N/mm 2 ) Elongation (mm) Modulus of elasticity (N/mm 2 ) Outer diameter ( mm) Thickness (mm) Two types of piles have been used in this study, these were: open ended and closed ended tube piles. All the piles in the experimental work were used with 32.8 mm diameter and 1.44 mm thickness. The embedment length of the model piles,which is considered in the experimental programs of the experiments, based onthe ratio of embedment length to pile diameter, (L/d) ratio. The pile type, outside diameter, and length of each pile size are shown in Table 3. Table 3 Model pile types and dimensions used in the experiment Pile designation Pile type Soil plug situation DOF Open - ended Full Plug DOU Open - ended Unplugged Diameter d (mm) Length ( mm ) L/d=12 L/d= SETTING UP OF MODEL PRESSED AND DRIVEN PILES Firstly, the bed of sand is prepared with controlled density as mentioned before. 10. SETTING UP OF MODEL DRIVEN PILES Strain gauge is sticking on the piles and then driving hammer is fixed to the box to penetrate the model piles to the desired length. The weight that is used to drive the model piles is determined approximately. The weight calculation takes into consideration many factors that affect the pile capacity. The model piles are vertically installed in specific hole that is made in the hammer plate and the rod of hammer is lowered to the model piles until the pile helmet is connected with the model pile. After the model pile head enters inside the helmet, the process of driving begins with dropping a specific weight from a specified height, and the blows number results are recorded each (25 mm) of model pile length until reaching the final desired length of penetration. The ram weight used to drive the model piles equals (1.9 kg). This weight was chosen to determine the best driving energy based on the weight ratio of pile to hammer (P/W) where P is the pile weight and W is the hammer weight. 11. SETTING UP OF MODEL PRESSED PILES In the installation frame the mechanical jack is used and fixed on the box to press the model pile to penetrate the desired length editor@iaeme.com

8 Mohammed Y. Fattah, Nahla M. Salim and Asaad M.B. Al-Gharrawi 12. RESULTS AND DISCUSSION The effect of removing the soil plug column which is formed during driving or pressing methods of installation is studied. The models include single and groups of pipe piles with different sand densities and length of piles. The effect of soil plug removal can be studied through testing a certain open ended pile configuration with different parameters such as, sand density, length to diameter ratio and two different methods of installation (driving and pressing ). The process of removal of soil plug, which is developed from driving or pressing of the pile, was done with several stages. In each stage, the amount of the elevated sand was measured to avoid elevating amount of the sand which is higher than the plug value that has been measured before removing process. Figures 4 and 5 show the effect of soil plugged removal on the pile load capacity with different sand densities, i.e. loose, medium and dense. The relationship between loading magnitude and the settlement for full plug and 100% plug removal has been drawn. All results are presented as a relationship between the applied load and the average of two dial gauge readings. From these figures, it can be noted that, the bearing capacity of the pile after removing the plug soil decreased with different values depending on the type of the soil, L/D ratio and pile installation. As shown in Figure (4 a, b and c), for driven pile in loose, medium and dense sand, the bearing resistance is reduced by 58.3%, 51.2% and 40.8% respectively for L/D =15 and 51%, 52% and 40.5% respectively for L/D =12 as shown Figure (4 d, e and f). It can be noted that the reduction in bearing resistance in the case of dense soil is smaller than that of loose and medium states. This may be due to the large contribution of the external friction resistance and low disturbance of bearing soil due to soil plug removal. The base and friction resistance have been separated by computing the friction resistance along the external pile surface using strain gauges. Figure 5 shows the bearing and friction resistance components of single pile. It can be seen that the pile with full plug has capacity higher than that of 100% soil plug removal. This is due to the presence of internal friction in fully plugged case, while the bearing resistance at 100% plug removal has been reduced till it reaches to zero value. The losses of the base resistance is due to the losing of plug weight and disturbance of soil below the pile wall. Figure 5 shows the bearing capacity for the pile after changing its length from 450 mm to 360 mm (L/D = 12 and L/D=15). It can be observed that the behavior is rarely the same for both cases of fully plugged and soil plug removal with taking into consideration the difference in bearing capacity and friction values for piles as shown in Table 4. Table 4 shows the complete details of the bearing capacity for single pile with both components of internal and external friction, bearing values when the pile was placed in the soil and after soil plug removal progress and for two cases of execution (i.e. driven and pressing) with different values of L/D and three different values of soil density. From the table mentioned above, it can be noted that the decrease in the bearing capacity of pile as a result of soil plug removal which leads to that the value of IFR value decreases up to zero in addition to a reason related to the distortion of the zone surrounding the end bearing and an obvious loss in the value of this component. To illustrate the contribution ratio for each of external and internal components and end bearing to the total bearing capacity of the pile, Table 5 was prepared to show the ratio of participation for end bearing which ranged between 54.7% to 78.3% for fully plugged cases, while in case of soil plug removal, the ratio decreased to the range between 14.4% to 28.7%. Table 5 illustrates the contribution ratios for components of internal and external friction and the end resistance to the total bearing capacity of pipe piles tested for various cases of densities of the soil, length of piles and the method of installation for both cases aforementioned and for fully plugged and 100% soil plug removal. From the table, it can be noticed that there is apparent decrease in the components of friction and end bearing in dense soil is which up to zero in both cases of loose and medium soil editor@iaeme.com

9 Effect of Plug Removal on Load Transfer in Plugged Open Ended Pile Behavior Figure 4 Load-settlement curve for driven single pipe pile with unplugged and fully plugged conditions under static load test. (a) loose, L/D=15, (b) medium, L/D=15,(c) dense, L/D=15, (d) loose, L/D=12, (e) medium, L/D=12, (f) dense, L/D= editor@iaeme.com

10 Mohammed Y. Fattah, Nahla M. Salim and Asaad M.B. Al-Gharrawi Figure 5 Load-friction and load- bearing curves for driven single pipe pile with unplugged and fully plugged conditions under static load test. (a) loose, L/D=15, (b) medium, L/D=15, (c) dense, L/D= editor@iaeme.com

11 Effect of Plug Removal on Load Transfer in Plugged Open Ended Pile Behavior Table 4 Pile bearing capacity according to tangent method with the values of external friction, internal friction and end bearing for single pile editor@iaeme.com

12 Mohammed Y. Fattah, Nahla M. Salim and Asaad M.B. Al-Gharrawi Table 5 Ratios of sharing for pile external friction, internal friction and end resistance to ultimate carrying single pipe pile capacity. 13. CONCLUSIONS 1. The behavior of open-ended piles with fully plugged is same as the closed-ended piles. Furthermore, the pile capacity of closed-ended piles is larger than that of open-ended piles in both loose and medium states of soil by about 10%, while in dense sand state of soil the capacity of the open ended pipe piles with fully plugged is larger than that closed-ended piles by 42% and 50% for length to diameter 12% and 15% respectively. 2. The removing of soil plug from piles will cause a reduction in pile load carrying capacity due to elimination of two components, internal friction and the confining in end bearing zone editor@iaeme.com

13 Effect of Plug Removal on Load Transfer in Plugged Open Ended Pile Behavior 3. The maximum reduction occurred in the dense state of soil with as a percentage of about 61.5%. 4. Based on the method of pile installation, it can be concluded that using of pressing method will yield a high pile capacity for loose and medium states of soil while the driving method of installation gives a higher capacity for dense state. 5. The sand column length increases with the progressing of the installation pressure when pressing method is used, but in driven piles, there is no systematic trend of the sand column length generated in the piles. 6. Long of piles have a higher probability of plugging and plugging penchant is also higher in dense and dilatant soils. REFERENCES [1] ASTM D3080, (1998), Standard Test Method for Direct Shear Test of Soils under Consolidated Drained Conditions, American Society for Testing and Materials. [2] ASTM D422, (2000), Standard Test Method for Particle-Size Analysis of Soils, American Society of Testing and Materials. [3] ASTM D854, (2005), Standard Test Method for Specific Gravity of Soil Solids by Water Pycnometer, American Society for Testing and Materials. [4] ASTM D4253, (2007), Standard Test Method for Maximum Index Density and Unit Weight of Soils Using a Vibratory Table, American Society for Testing and Materials. [5] ASTM D4254, (2007), Standard Test Method for Minimum Index Density and Unit Weight of Soils and Calculation of Relative Density, American Society for Testing and Materials. [6] ASTM D1143, D1143M, 07, (2013), Standard Test Method for Piles under Static Axial Compressive Load, American Society of Testing and Materials. [7] Fattah, M. Y., Al-Soudani, W. H. S., (2016), "Bearing Capacity of Open-Ended Pipe Piles with Restricted Soil Plug", Ships and Offshore Structures, Vol. 11, 5, pp , Taylor & Francis, DOI: / , London W1T 3JH, UK. [8] Fattah, M. Y., Al-Soudani, W. H. S., (2016), " Bearing Capacity of Closed and Open Ended Pipe Piles Installed in Loose Sand with Emphasis on Soil Plug", Indian Journal of Geo-Marine Sciences Vol. 45(5), May 2016, pp [9] Karlowskis, V., (2014), Soil Plugging of Open-Ended Piles During Impact Driving in Cohesionless Soil, Master of Science Thesis, Royal Institute of Technology (KTH), Department of Civil and Architectural Engineering, Stockholm, Sweden [10] Paikowski, S.G., Whitman, R.V. and Baligh, M.M. (1989), A New Look at the Phenomenon of Offshore Pile Plugging, Marine Geotechnical, Vol. 8, pp [11] Paik, K. and Salgado, R. (2003), "Determination of bearing capacity of open-ended piles in sand, Journal of Geotechnical and Geoenvironmental Engineering, ASCE, Vol. 129, No. 1, pp [12] Shighait, W. H., (2013), Effect of Plugging on the Load Carrying Capacity of Closed and Open Ended Pipe Piles in Sands, M.Sc. Thesis, University of Baghdad, Iraq. [13] Kavitha P. E., Dr. Beena K. S. and Dr. Narayanan K. P., Analytical Study on Soil-Pile Interaction Effect in the Variation of Natural Frequency of a Single Pile. International Journal of Civil Engineering and Technology, 5(12), 2014, pp [14] Mohammed M. Salman And Prof. Dr. Abdulaziz Abdulrassol Aziz, The Effect of Improvement Surrounding Soil on Bored Pile Friction Capacity. International Journal of Civil Engineering and Technology, 7(1), 2016, pp editor@iaeme.com

Effect of Particle Size Distribution of Cohesionless Soil and Pile Diameter on the Behavior of Open Ended Pipe Piles

Effect of Particle Size Distribution of Cohesionless Soil and Pile Diameter on the Behavior of Open Ended Pipe Piles M.R. Mahmood Building & Const. Eng. Dept. University of Technology, Iraq mahmoudal_qaissy@yahoo.com Mobile:+964 7901315445 S.J. Abdullah Building and Construction Eng. Dept. University of Technology, Baghdad,

More information

Global Journal of Engineering Science and Research Management

Global Journal of Engineering Science and Research Management EFFECT OF PARTICLE SIZE DISTRIBUTION OF COHESION LESS SOILS AND PILE DIAMETERS ON THE BEHAVIOR OF SOIL COLUMN INSIDE THE OPEN ENDED PIPE PILES UNDER DIFFERENT SATURATION CONDITIONS Mahmood R. Mahmood*,

More information

Development of Soil Plug in Pipe Pile: A Review

Development of Soil Plug in Pipe Pile: A Review Development of Soil Plug in Pipe Pile: A Review Aparna Verma Civil Engineering Department MMMUT Gorakhpur, India. S.M. Ali Jawaid Civil Engineering Department MMMUT Gorakhpur, India. Abstract In case of

More information

Bearing capacity of closed and open ended pipe piles installed in loose sand with emphasis on soil plug

Bearing capacity of closed and open ended pipe piles installed in loose sand with emphasis on soil plug Indian Journal of Geo-Marine Science Vol.45 (5),May 2016,pp. 703-724 Bearing capacity of closed and open ended pipe piles installed in loose sand with emphasis on soil plug Mohammed Y. Fattah1 & Wissam

More information

LATERAL CAPACITY OF SKIRT FOUNDATION ON LOOSE SUBMERGED SAND

LATERAL CAPACITY OF SKIRT FOUNDATION ON LOOSE SUBMERGED SAND Int. J. Chem. Sci.: 14(S1), 2016, 295-301 ISSN 0972-768X www.sadgurupublications.com LATERAL CAPACITY OF SKIRT FOUNDATION ON LOOSE SUBMERGED SAND R. MANOJ KANNAN and S. CHEZHIYAN * Department of Civil

More information

The effects of pile diameter and sleeve height on incremental filling ratio (IFR)

The effects of pile diameter and sleeve height on incremental filling ratio (IFR) Japanese Geotechnical Society Special Publication The 6th Japan-China Geotechnical Symposium The effects of pile diameter and sleeve height on incremental filling ratio (IFR) Janaka J. Kumara i), Yoshiaki

More information

EXPERIMENTAL PROGRAMME

EXPERIMENTAL PROGRAMME CHAPTER 3 EXPERIMENTAL PROGRAMME 3.1 INTRODUCTION The critical review of the literature presented in the previous chapter reveals the limitations of the experimental studies carried out so far in the field

More information

EARTHQUAKE EFFECT ON SINGLE PILE BEHAVIOR WITH VARIOUS FACTOR OF SAFETY AND DEPTH TO DIAMETER RATIO IN LIQUEFIABLE SAND

EARTHQUAKE EFFECT ON SINGLE PILE BEHAVIOR WITH VARIOUS FACTOR OF SAFETY AND DEPTH TO DIAMETER RATIO IN LIQUEFIABLE SAND International Journal of Civil Engineering and Technology (IJCIET) Volume 9, Issue 4, April 218, pp. 1253 1262, Article ID: IJCIET_9_4_14 Available online at http://www.iaeme.com/ijciet/issues.asp?jtype=ijciet&vtype=9&itype=4

More information

SOIL IMPROVEMENT USING WASTE TIRE CHIPS

SOIL IMPROVEMENT USING WASTE TIRE CHIPS International Journal of Civil Engineering and Technology (IJCIET) Volume 9, Issue 8, August 2018, pp. 1338 1345, Article ID: IJCIET_09_08_135 Available online at http://www.iaeme.com/ijciet/issues.asp?jtype=ijciet&vtype=9&itype=8

More information

353. Fellenius, B.H., The response of a "plug" in an open-toe pipe pile Geotechnical Engineering Journal of the SEAGS & AGSSEA 46(2)

353. Fellenius, B.H., The response of a plug in an open-toe pipe pile Geotechnical Engineering Journal of the SEAGS & AGSSEA 46(2) 353. Fellenius, B.H., 2015. The response of a "plug" in an open-toe pipe pile Geotechnical Engineering Journal of the SEAGS & AGSSEA 46(2) 82-86. The response of a "plug" in an open-toe pipe pile Bengt

More information

EXPERIMENTAL STUDY ON BEARING CAPACITY OF SKIRTED FOUNDATIONS ON DRY GYPSEOUS SOIL

EXPERIMENTAL STUDY ON BEARING CAPACITY OF SKIRTED FOUNDATIONS ON DRY GYPSEOUS SOIL International Journal of Civil Engineering and Technology (IJCIET) Volume 9, Issue 10, October 2018, pp. 1910 1922, Article ID: IJCIET_09_10_190 Available online at http://www.iaeme.com/ijciet/issues.asp?jtype=ijciet&vtype=9&itype=10

More information

Effects of axial loads and soil density on pile group subjected to triangular soil movement

Effects of axial loads and soil density on pile group subjected to triangular soil movement Effects of axial loads and soil density on pile group subjected to triangular soil movement Al Abboodi, I and Toma Sabbagh, TM Title Authors Type URL Effects of axial loads and soil density on pile group

More information

EFFECT OF VERTICAL LOAD ON THE LATERAL BEHAVIOUR OF GROUP OF PILES

EFFECT OF VERTICAL LOAD ON THE LATERAL BEHAVIOUR OF GROUP OF PILES EFFECT OF VERTICAL LOAD ON THE LATERAL BEHAVIOUR OF GROUP OF PILES Ashish K. Masani 1, Prof. M. G. Vanza 2 1 PG Student, Applied Mechanics Department, L D College of Engineering, Ahmedabad, Gujarat, India

More information

An Experimental Study on Vertically Loaded Driven and Cast- In-Situ Piles

An Experimental Study on Vertically Loaded Driven and Cast- In-Situ Piles IOSR Journal of Mechanical and Civil Engineering (IOSR-JMCE) e-issn: 2278-1684,p-ISSN: 2320-334X, Volume 11, Issue 2 Ver. III (Mar- Apr. 2014), PP 43-48 An Experimental Study on Vertically Loaded Driven

More information

Behaviour of Basalt Fibre Reinforced Polymer (BFRP) Composites Confined RCC Piles Skin Friction in Cohesion less Soil

Behaviour of Basalt Fibre Reinforced Polymer (BFRP) Composites Confined RCC Piles Skin Friction in Cohesion less Soil www.cafetinnova.org Indexed in Scopus Compendex and Geobase Elsevier, Chemical Abstract Services-USA, Geo-Ref Information Services-USA, List B of Scientific Journals, Poland, Directory of Research Journals

More information

Research Paper PERFORMANCE OF STRIP FOOTING ON SANDY SOIL DUE TO TUNNELING S.Hariswaran 1, K.Premalatha 2, K.Raja 3

Research Paper PERFORMANCE OF STRIP FOOTING ON SANDY SOIL DUE TO TUNNELING S.Hariswaran 1, K.Premalatha 2, K.Raja 3 Research Paper PERFORMANCE OF STRIP FOOTING ON SANDY SOIL DUE TO TUNNELING S.Hariswaran 1, K.Premalatha 2, K.Raja 3 Address for Correspondence 1 Assistant Professor, Department of Civil Engineering, Agni

More information

Effect of Compressive Load on Uplift Capacity of Pile Groups in Sand

Effect of Compressive Load on Uplift Capacity of Pile Groups in Sand Effect of Compressive Load on Uplift Capacity of Pile Groups in Sand K. Shanker 1, P. K. Basudhar 2 and N. R. Patra 3 The Asian Review of Civil Engineering ISSN: 2249-6203 Vol. 2 No. 2, 2013, pp. 10-22

More information

Journal of Engineering Science and Technology Review 11 (3) (2018) Research Article. Jasim M. Abbas* and Qasim Ibrahim Hussain

Journal of Engineering Science and Technology Review 11 (3) (2018) Research Article. Jasim M. Abbas* and Qasim Ibrahim Hussain Jestr Journal of Engineering Science and Technology Review 11 (3) (218) 174-179 Research Article The Effect of Pile Cross Section on the Lateral behavior of Piles Under Combined Loading Jasim M. Abbas*

More information

EXPERIMENTAL STUDY ON PFRP CONFINED RC DRIVEN PILES SUBJECTED TO VERTICAL LOADS

EXPERIMENTAL STUDY ON PFRP CONFINED RC DRIVEN PILES SUBJECTED TO VERTICAL LOADS International Journal of Civil Engineering and Technology (IJCIET) Volume 9, Issue 4, April 2018, pp. 1307 1315, Article ID: IJCIET_09_04_147 Available online at http://www.iaeme.com/ijciet/issues.asp?jtype=ijciet&vtype=9&itype=4

More information

ABSTRACT. KEY WORDS: Tubular piles; composite behavior; offshore structures; push-out strength; bond strength; slip.

ABSTRACT. KEY WORDS: Tubular piles; composite behavior; offshore structures; push-out strength; bond strength; slip. Proceedings of The Twelfth (22) International Offshore and Polar Engineering Conference Kitakyushu, Japan, May 26 31, 22 Copyright 22 by The International Society of Offshore and Polar Engineers ISBN 1-88653-58-3

More information

Typical set up for Plate Load test assembly

Typical set up for Plate Load test assembly Major disadvantages of field tests are Laborious Time consuming Heavy equipment to be carried to field Short duration behavior Plate Load Test Sand Bags Platform for loading Dial Gauge Testing Plate Foundation

More information

MODEL TEST ON UPLIFT CAPACITY OF PILE ANCHORS IN COHESSIONLESS SOIL

MODEL TEST ON UPLIFT CAPACITY OF PILE ANCHORS IN COHESSIONLESS SOIL MODEL TEST ON UPLIFT CAPACITY OF PILE ANCHORS IN COHESSIONLESS SOIL Amit Kotal 1, A.k.khan 2 1 M-tech. Student, Civil engineering department, NIT Jamshedpur, Jharkhand, India 2 Professor, Civil engineering

More information

CHAPTER 5 FRESH AND HARDENED PROPERTIES OF CONCRETE WITH MANUFACTURED SAND

CHAPTER 5 FRESH AND HARDENED PROPERTIES OF CONCRETE WITH MANUFACTURED SAND 61 CHAPTER 5 FRESH AND HARDENED PROPERTIES OF CONCRETE WITH MANUFACTURED SAND 5.1 GENERAL The material properties, mix design of M 20, M 30 and M 40 grades of concrete were discussed in the previous chapter.

More information

BEHAVIOUR OF GEOTEXTILE REINFORCED STONE COLUMNS MANITA DAS, A.K.DEY ABSTRACT

BEHAVIOUR OF GEOTEXTILE REINFORCED STONE COLUMNS MANITA DAS, A.K.DEY ABSTRACT BEHAVIOUR OF GEOTEXTILE REINFORCED STONE COLUMNS MANITA DAS, A.K.DEY ABSTRACT Stone columns are being used to improve the bearing capacity and reduce the settlement of a weak or soft soil. The improvement

More information

ANALYTICAL AND EXPERIMENTAL STUDY ON COMPOSITE FRAMES

ANALYTICAL AND EXPERIMENTAL STUDY ON COMPOSITE FRAMES ANALYTICAL AND EXPERIMENTAL STUDY ON COMPOSITE FRAMES ARCHANA P1, ANJUGHAP PRIYA R2, SARANYA M3 1PG Student, Dept. of Civil Engineering, Valliammai Engineering College, Chennai, Tamil Nadu 2 Assistant

More information

Model Tests to Determine the Settlement Characteristics of Steel Hollow Piles under Cyclic Loading Embedded in Silty Sands

Model Tests to Determine the Settlement Characteristics of Steel Hollow Piles under Cyclic Loading Embedded in Silty Sands IJSTE - International Journal of Science Technology & Engineering Volume 1 Issue 11 May 2015 ISSN (online): 2349-784X Model Tests to Determine the Settlement Characteristics of Steel Hollow Piles under

More information

AN INVESTIGATION OF SEISMIC RETROFIT OF COLUMNS IN BUILDINGS USING CONCRETE JACKET

AN INVESTIGATION OF SEISMIC RETROFIT OF COLUMNS IN BUILDINGS USING CONCRETE JACKET AN INVESTIGATION OF SEISMIC RETROFIT OF COLUMNS IN BUILDINGS USING CONCRETE JACKET Gnanasekaran, K. 1 and Amlan K. Sengupta 2 1 Ph.D. Scholar, Dept. of Civil Engineering, Indian Institute of Technology

More information

ENGINEERING PROPERTIES AND MAINTENANCE OF PUTTING GREENS James R. Crum Department of Crop and Soil Sciences Michigan State University

ENGINEERING PROPERTIES AND MAINTENANCE OF PUTTING GREENS James R. Crum Department of Crop and Soil Sciences Michigan State University ENGINEERING PROPERTIES AND MAINTENANCE OF PUTTING GREENS James R. Crum Department of Crop and Soil Sciences Michigan State University Introduction Our overall objective of this research project was to

More information

Effect of Soil Reinforcement on Shear Strength and Settlement of Cohesive- Frictional Soil

Effect of Soil Reinforcement on Shear Strength and Settlement of Cohesive- Frictional Soil Int. J. of GEOMATE, Sept., Int. J. 212, of GEOMATE, Vol. 3, No. Sept., 1 (Sl. 212, No. 5), Vol. pp. 3, 38-313 No. 1 (Sl. No. 5), pp. 38-313 Geotec., Const. Mat. & Env., ISSN:2186-2982(P), 2186-299(O),

More information

Axially Loaded Behavior of Driven PC Piles

Axially Loaded Behavior of Driven PC Piles Axially Loaded Behavior of Driven PC Piles Shih-Tsung Hsu Associate Professor, Department of Construction Engineering, Chaoyang University of Technology, E-mail address: sthsu@cyut.edu.tw Abstract. To

More information

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 1, No 3, 2010

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 1, No 3, 2010 ABSTRACT Evaluation of Shear Strain Distribution In Polypropylene Fiber Reinforced Cement Concrete Moderate Deep Beams Vinu R.Patel 1, Pandya.I.I 2 1- Assistant Professor in Applied Mechanics Department,

More information

EFFICIENCY OF MICROPILE FOR SEISMIC RETROFIT OF FOUNDATION SYSTEM

EFFICIENCY OF MICROPILE FOR SEISMIC RETROFIT OF FOUNDATION SYSTEM EFFICIENCY OF MICROPILE FOR SEISMIC RETROFIT OF FOUNDATION SYSTEM YAMANE TAKASHI, NAKATA YOSHINORI And OTANI YOSHINORI SUMMARY Micropile is drilled and grouted pile with steel pipes which diameters is

More information

SITE INVESTIGATION Validation and Interpretation of data

SITE INVESTIGATION Validation and Interpretation of data SITE INVESTIGATION Validation and Interpretation of data Dr. G.Venkatappa Rao The Impact 1 The Need To determine the type of foundation To assess bearing capacity/settlement Location of Ground water table,issues

More information

PERFORMANCE OF PILED RAFT WITH VARYING PILE LENGTH ABSTRACT

PERFORMANCE OF PILED RAFT WITH VARYING PILE LENGTH ABSTRACT 50 th IGC 50 th INDIAN GEOTECHNICAL CONFERENCE 17 th 19 th DECEMBER 015, Pune, Maharashtra, India Venue: College of Engineering (Estd. 185), Pune, India PERFORMANCE OF PILED RAFT WITH VARYING PILE LENGTH

More information

Stress-Strain and Strength Characteristics of Sand-Silt Mixtures

Stress-Strain and Strength Characteristics of Sand-Silt Mixtures Stress-Strain and Strength Characteristics of Sand-Silt Mixtures Banupriya S Assistant Professor, Department of Civil Engineering Vels Institute of Science,Technology and Advance Studies Chennai,India

More information

Performance of Bituminous Coats for Dragload Reduction in Precast Piles

Performance of Bituminous Coats for Dragload Reduction in Precast Piles Performance of Bituminous Coats for Dragload Reduction in Precast Piles M.G. Khare Research Scholar, Indian Institute of Technology Madras, Chennai, India E-mail: makarandkhare@yahoo.com S.R. Gandhi Professor,

More information

twenty six concrete construction: foundation design ELEMENTS OF ARCHITECTURAL STRUCTURES: FORM, BEHAVIOR, AND DESIGN DR. ANNE NICHOLS SPRING 2013

twenty six concrete construction: foundation design ELEMENTS OF ARCHITECTURAL STRUCTURES: FORM, BEHAVIOR, AND DESIGN DR. ANNE NICHOLS SPRING 2013 ELEMENTS OF ARCHITECTURAL STRUCTURES: FORM, BEHAVIOR, AND DESIGN DR. ANNE NICHOLS SPRING 2013 lecture twenty six concrete construction: www.tamu.edu foundation design Foundations 1 Foundation the engineered

More information

Page 1 of 46 Exam 1. Exam 1 Past Exam Problems without Solutions NAME: Given Formulae: Law of Cosines: C. Law of Sines:

Page 1 of 46 Exam 1. Exam 1 Past Exam Problems without Solutions NAME: Given Formulae: Law of Cosines: C. Law of Sines: NAME: EXAM 1 PAST PROBLEMS WITHOUT SOLUTIONS 100 points Tuesday, September 26, 2017, 7pm to 9:30 You are allowed to use a calculator and drawing equipment, only. Formulae provided 2.5 hour time limit This

More information

twenty four foundations and retaining walls Foundation Structural vs. Foundation Design Structural vs. Foundation Design

twenty four foundations and retaining walls Foundation Structural vs. Foundation Design Structural vs. Foundation Design ALIED ARCHITECTURAL STRUCTURES: STRUCTURAL ANALYSIS AND SYSTEMS DR. ANNE NICHOLS SRING 2018 lecture twenty four Foundation the engineered interface between the earth and the structure it supports that

More information

DOUBLE SKIN TUBULAR COLUMNS CONFINED WITH GFRP

DOUBLE SKIN TUBULAR COLUMNS CONFINED WITH GFRP International Journal of Civil Engineering and Technology (IJCIET) Volume 7, Issue 6, November-December 2016, pp. 536 543, Article ID: IJCIET_07_06_059 Available online at http://www.iaeme.com/ijciet/issues.asp?jtype=ijciet&vtype=7&itype=6

More information

SOIL MECHANICS CIVIL ENGINEERING VIRTUAL LABORATORY

SOIL MECHANICS CIVIL ENGINEERING VIRTUAL LABORATORY SOIL MECHANICS CIVIL ENGINEERING VIRTUAL LABORATORY EXPERIMENT: 10 TRIAXIAL TEST AIM OF THE EXPERIMENT: To find the shear of the soil by Undrained Triaxial Test. APPARATUS REQUIRED: a) Special: i. A constant

More information

IGC. 50 th INDIAN GEOTECHNICAL CONFERENCE BEHAVIOUR OF GEOTEXTILE ENCASED QUARRY WASTE COLUMN SUBJECTED TO SHEAR LOADING IN SOFT CLAY

IGC. 50 th INDIAN GEOTECHNICAL CONFERENCE BEHAVIOUR OF GEOTEXTILE ENCASED QUARRY WASTE COLUMN SUBJECTED TO SHEAR LOADING IN SOFT CLAY th th INDIAN GEOTECHNICAL CONFERENCE 17 th 19 th DECEMBER, Pune, Maharashtra, India Venue: College of Engineering (Estd. 184), Pune, India BEHAVIOUR OF GEOTEXTILE ENCASED QUARRY WASTE COLUMN SUBJECTED

More information

Improvement Of Sandy Soil Properties By Using Bentonite

Improvement Of Sandy Soil Properties By Using Bentonite Improvement Of Sandy Soil Properties By Using Bentonite Assistant Lecturer. Tawfiq Aamir Jawad / Department of Structures and Water Resources/ E-mail. Tawfeeq76@yahoo.com Assistant Lecturer. Asaad Mohammed

More information

STRENGTH AND BEHAVIOR OF ELLIPTICAL STEEL TUBE BEAMS

STRENGTH AND BEHAVIOR OF ELLIPTICAL STEEL TUBE BEAMS International Journal of Civil Engineering and Technology (IJCIET) Volume 10, Issue 01, January 2019, pp. 2658-2669, Article ID: IJCIET_10_01_238 Available online at http://www.iaeme.com/ijciet/issues.asp?jtype=ijciet&vtype=10&itype=01

More information

SHEAR STRENGTH CHARACTERISTICS AND STATIC RESPONSE OF SAND-TIRE CRUMB MIXTURES FOR SEISMIC ISOLATION

SHEAR STRENGTH CHARACTERISTICS AND STATIC RESPONSE OF SAND-TIRE CRUMB MIXTURES FOR SEISMIC ISOLATION SHEAR STRENGTH CHARACTERISTICS AND STATIC RESPONSE OF SAND-TIRE CRUMB MIXTURES FOR SEISMIC ISOLATION Anbazhagan Panjamani*, Manohar D.R. Department of Civil Engineering, Indian Institute of Science, Bangalore,

More information

Assalamualaikum & Good Morning (May All Of You Gain A Better Understanding)

Assalamualaikum & Good Morning (May All Of You Gain A Better Understanding) Assalamualaikum & Good Morning (May All Of You Gain A Better Understanding) Always Try To Do The Best In Your Life TYPES OF FOUNDATION TYPES OF FOUNDATION a) Shallow Foundation System i) Spread Foundation

More information

BEHAVIOR IMPROVEMENT OF FOOTINGS ON SOFT CLAY UTILIZING GEOFOAM

BEHAVIOR IMPROVEMENT OF FOOTINGS ON SOFT CLAY UTILIZING GEOFOAM BEHAVIOR IMPROVEMENT OF FOOTINGS ON SOFT CLAY UTILIZING GEOFOAM G. E. ABDELRAHMAN AND A. F. ELRAGI Department of Civil Engineering, Fayoum University Fayoum, Egypt ABSTRACT: EPS, expanded poly-styrene

More information

Influence of Material Variability on the Seismic Response of Pile Foundation

Influence of Material Variability on the Seismic Response of Pile Foundation Influence of Material Variability on the Seismic Response of Pile Foundation Satarupa Sengupta*, Dr. Sima Ghosh Civil Engg. Department, National Institute of Technology. Agartala, PIN 799055, E-mail ID:

More information

NPTEL Course GROUND IMPROVEMENT USING MICROPILES

NPTEL Course GROUND IMPROVEMENT USING MICROPILES Lecture 22 NPTEL Course GROUND IMPROVEMENT USING MICROPILES Prof. G L Sivakumar Babu Department of Civil Engineering Indian Institute of Science Bangalore 560012 Email: gls@civil.iisc.ernet.in Contents

More information

NPTEL Course. GROUND IMPROVEMENT Factors affecting the behaviour and performance of reinforced soil

NPTEL Course. GROUND IMPROVEMENT Factors affecting the behaviour and performance of reinforced soil Lecture 27 NPTEL Course GROUND IMPROVEMENT Factors affecting the behaviour and performance of reinforced soil Prof. G L Sivakumar Babu Department of Civil Engineering Indian Institute of Science Bangalore

More information

Model tests on piled raft subjected to lateral soil movement

Model tests on piled raft subjected to lateral soil movement Model tests on piled raft subjected to lateral soil movement Toma Sabbagh, TM and Al Abboodi, I http://dx.doi.org/1.18/19386362.217.129661 Title Authors Type URL Model tests on piled raft subjected to

More information

twenty seven concrete construction: foundation design Foundation Structural vs. Foundation Design Structural vs. Foundation Design

twenty seven concrete construction: foundation design Foundation Structural vs. Foundation Design Structural vs. Foundation Design ARCHITECTURAL STRUCTURES: FORM, BEHAVIOR, AND DESIGN DR. ANNE NICHOLS SRING 2017 lecture twenty seven Foundation the engineered interface between the earth and the structure it supports that transmits

More information

1G Model Study on the behavior of Piled Raft Foundation

1G Model Study on the behavior of Piled Raft Foundation IJSTE - International Journal of Science Technology & Engineering Volume 3 Issue 02 August 2016 ISSN (online): 2349-784X 1G Model Study on the behavior of Piled Raft Foundation Aleena Tom Sindhu A R M.

More information

Code No: RR Set No. 1

Code No: RR Set No. 1 Code No: RR320101 Set No. 1 III B.Tech Supplimentary Examinations, Aug/Sep 2008 GEOTECHNICAL ENGINEERING (Civil Engineering) Time: 3 hours Max Marks: 80 Answer any FIVE Questions All Questions carry equal

More information

Skirted Spudcan Sheet Pile Wall Interaction during Jack- Up Rig Installation and Removal in a Harbour Area

Skirted Spudcan Sheet Pile Wall Interaction during Jack- Up Rig Installation and Removal in a Harbour Area Skirted Spudcan Sheet Pile Wall Interaction during Jack- Up Rig Installation and Removal in a Harbour Area L. Kellezi GEO - Danish Geotechnical Institute 1 Maglebjergvej, DK 2800 Copenhagen, Denmark G.

More information

Shake Table Testing of GRS Bridge Abutments

Shake Table Testing of GRS Bridge Abutments Shake Table Testing of GRS Bridge Abutments Prof. John S. McCartney and Yewei Zheng University of California San Diego Department of Structural Engineering Presentation to: NHERI-UCSD Geotechnical Workshop

More information

BUCKLING BEHAVIOR OF PARTIALLY EMBEDDED REINFORCED CONCRETE PILES IN SAND

BUCKLING BEHAVIOR OF PARTIALLY EMBEDDED REINFORCED CONCRETE PILES IN SAND VOL. 2, NO. 4, AUGUST 27 ISSN 1819-668 26-27 Asian Research Publishing Network (ARPN). All rights reserved. BUCKLING BEHAVIOR OF PARTIALLY EMBEDDED REINFORCED CONCRETE PILES IN SAND P. Senthil Kumar 1,

More information

Performance Study for No-Tilt Condition of Bi-Angle Shape Skirted Footing in Clayey Soil Subjected to Eccentric Load

Performance Study for No-Tilt Condition of Bi-Angle Shape Skirted Footing in Clayey Soil Subjected to Eccentric Load International Journal of Engineering Research and Development e-issn : 2278-067X, p-issn : 2278-800X, www.ijerd.com Volume 2, Issue 8 (August 2012), PP. 14-20 Performance Study for No-Tilt Condition of

More information

3.1 Scope of the work-capacity Estimation of Drilled Shaft Bearing on Rock

3.1 Scope of the work-capacity Estimation of Drilled Shaft Bearing on Rock Chapter 3-Methodology 3.1 Scope of the work-capacity Estimation of Drilled Shaft Bearing on Rock The research work involved the use of high strain dynamic stress wave measurements for capacity estimation

More information

INVESTIGATION ON BEHAVIOUR OF SOILS REINFORCED WITH SHREDDED WASTE TYRES

INVESTIGATION ON BEHAVIOUR OF SOILS REINFORCED WITH SHREDDED WASTE TYRES IGC 2009, Guntur, INDIA INVESTIGATION ON BEHAVIOUR OF SOILS REINFORCED WITH SHREDDED WASTE TYRES V. Vinot Post-graduate Student, Department of Civil Engg., Indian Institute of Technology, Guwahati 781039,

More information

Metal-plate connections loaded in combined bending and tension

Metal-plate connections loaded in combined bending and tension Metal-plate connections loaded in combined bending and tension Ronald W. Wolfe Abstract This study evaluates the load capacity of metal-plate connections under combined bending and axial loads and shows

More information

THE EFFECT OF LATERAL CONFINEMENT ON THE SETTLEMENT CHARACTERISTICS OF SHALLOW FOUNDATIONS ON SAND

THE EFFECT OF LATERAL CONFINEMENT ON THE SETTLEMENT CHARACTERISTICS OF SHALLOW FOUNDATIONS ON SAND Geotec., Const. Mat. & Env., DOI: https://doi.org/10.21660/2018.51.65933 ISSN: 2186-2982 (Print), 2186-2990 (Online), Japan THE EFFECT OF LATERAL CONFINEMENT ON THE SETTLEMENT CHARACTERISTICS OF SHALLOW

More information

J.-H. YIN Department of Civil & Structural Engineering, The Hong Kong Polytechnic University Kowloon, Hong Kong, China

J.-H. YIN Department of Civil & Structural Engineering, The Hong Kong Polytechnic University Kowloon, Hong Kong, China AN INNOVATIVE DOUBLE CELL TRIAXIAL SYSTEM FOR CONTINUOUS MEASUREMENT OF THE VOLUME CHANGE OF GASEOUS OR UNSATURATED MARINE SOILS AND TWO OTHER ADVANCED SOIL TESTING SYSTEMS J.-H. YIN Department of Civil

More information

NUMERICAL SIMULATION ON LOCAL BOND-SLIP BETWEEN STEEL AND CONCRETE WITH EXPERIMENTAL VERIFICATION

NUMERICAL SIMULATION ON LOCAL BOND-SLIP BETWEEN STEEL AND CONCRETE WITH EXPERIMENTAL VERIFICATION TPT TPT TPT Professor, TPT Ph. NUMERICAL SIMULATION ON LOCAL BOND-SLIP BETWEEN STEEL AND CONCRETE WITH EXPERIMENTAL VERIFICATION 1 Xilin LuTP PT, Yuguang DongTP PT ABSTRACT The bond stress vs. slip relationship

More information

Misan University - College of Engineering Civil Engineering Department

Misan University - College of Engineering Civil Engineering Department CHAPTER 2 Soil and Excavations Soil investigation including two phases: surface investigation and subsurface investigation Surface investigation involves making a preliminary judgment about the site s

More information

IRAQI GYPSEOUS SOIL STABILIZED BY ORDINARY AND ENCASED STONE COLUMNS

IRAQI GYPSEOUS SOIL STABILIZED BY ORDINARY AND ENCASED STONE COLUMNS International Journal of Civil Engineering and Technology (IJCIET) Volume 7, Issue 6, November-December 216, pp. 179 192, Article ID: IJCIET_7_6_2 Available online at http://www.iaeme.com/ijciet/issues.asp?jtype=ijciet&vtype=7&itype=6

More information

STATIC ALTERNATING CYCLIC HORIZONTAL LOAD TESTS ON DRIVEN

STATIC ALTERNATING CYCLIC HORIZONTAL LOAD TESTS ON DRIVEN STATIC ALTERNATING CYCLIC HORIZONTAL LOAD TESTS ON DRIVEN STEEL PIPE PILES OF FOUNDATIONS FOR HIGHWAY BRIDGES Kouichi TOMISAWA, Civil Engineering Research Institute of Hokkaido, Japan Satoshi NISHIMOTO,

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-31 62 13.26 (April 2006) ----------------------------- Preparing Activity: NAVFAC Replacing without change UFGS-02466 (August 2004) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

EFFECTS OF SHEAR SPAN-DEPTH RATIO ON THE BEHAVIOR OF HYBRID REINFORCED CONCRETE CONTINUOUS STRAIGHT DEEP BEAM

EFFECTS OF SHEAR SPAN-DEPTH RATIO ON THE BEHAVIOR OF HYBRID REINFORCED CONCRETE CONTINUOUS STRAIGHT DEEP BEAM International Journal of Civil Engineering and Technology (IJCIET) Volume 9, Issue 12, December 2018, pp. 985 992, Article ID: IJCIET_09_12_101 Available online at http://www.ia aeme.com/ijciet/issues.asp?jtype=ijciet&vtype=

More information

IGC. 50 th INDIAN GEOTECHNICAL CONFERENCE

IGC. 50 th INDIAN GEOTECHNICAL CONFERENCE BEARING CAPACITY IMPROVEMENT OF CONFINED FOOTINGS IN EXPANSIVE SOILS Sareesh Chandrwanshi 1, Rakesh Kumar 2 and P.K. Jain 3 The civil structures constructed on expansive soils encounters severe problems

More information

INTERNATIONAL JOURNAL OF APPLIED ENGINEERING RESEARCH, DINDIGUL Volume 1, No 2, 2010

INTERNATIONAL JOURNAL OF APPLIED ENGINEERING RESEARCH, DINDIGUL Volume 1, No 2, 2010 Micro Mechanical Measurement of Concrete Strain to Evaluate Principle Strain Distribution in Steel Fiber Reinforced Cement Concrete Moderate Deep Beams across it s width and depths Vinu R. Patel, I. I.

More information

THE EXPERIMENTAL INVESTIGATION OF FAILURE MECHANISM AND BEARING CAPACITY OF DIFFERENT TYPES OF SHALLOW FOUNDATIONS

THE EXPERIMENTAL INVESTIGATION OF FAILURE MECHANISM AND BEARING CAPACITY OF DIFFERENT TYPES OF SHALLOW FOUNDATIONS THE EXPERIMENTAL INVESTIGATION OF FAILURE MECHANISM AND BEARING CAPACITY OF DIFFERENT TYPES OF SHALLOW FOUNDATIONS Nissanka Fernando, (Email: nfcharith@yahoo.com) Eranga Sendanayake, (Email: eranga_7@yahoo.com)

More information

Pile foundations Introduction

Pile foundations Introduction Engineering manual No. 12 Updated: 06/2018 Pile foundations Introduction Program: Pile, Pile CPT, Pile Group The objective of this engineering manual is to explain the practical use of programs for the

More information

Analysis of skin friction in prebored and precast piles

Analysis of skin friction in prebored and precast piles Japanese Geotechnical Society Special Publication The 6th Japan-Korea Geotechnical Workshop Analysis of skin friction in prebored and precast piles Sangseom Jeong i), Gyoungja Jung ii), Dohyun Kim iii)

More information

Capstone C O N S U L T A N T S

Capstone C O N S U L T A N T S Ultrasonic Pulse Velocity Tests These tests are primarily done to establish: the homogeneity of concrete presence of cracks, voids and other imperfections changes in quality of concrete over time this

More information

SOIL PRESSURE IN EMBANKMENT STABILIZATIONS

SOIL PRESSURE IN EMBANKMENT STABILIZATIONS SOIL PRESSURE IN EMBANKMENT STABILIZATIONS Analysis of the 3D shadowing effect of piles Dipl.-Ing. M. Filus Fides DV-Partner GmbH ABSTRACT: Pile checks required by the codes alone are usually not sufficient

More information

Behavior of curved in plan hollow tubular flange beams with corrugated webs using experimental work

Behavior of curved in plan hollow tubular flange beams with corrugated webs using experimental work Behavior of curved in plan hollow tubular flange beams with corrugated webs using experimental work 1 Khaled Gamal Abd-AlHady, 2 Zainab Ebraheem Abd-Elshafy 1 Demonstrator-civil engineering department-faculty

More information

Characterization of smear zone caused by mandrel action

Characterization of smear zone caused by mandrel action University of Wollongong Research Online Faculty of Engineering and Information Sciences - Papers: Part A Faculty of Engineering and Information Sciences 2015 Characterization of smear zone caused by mandrel

More information

Strain Limits for Concrete Filled Steel Tubes in AASHTO Seismic Provisions. PIs: Mervyn Kowalsky and James Nau RA: Nicole King

Strain Limits for Concrete Filled Steel Tubes in AASHTO Seismic Provisions. PIs: Mervyn Kowalsky and James Nau RA: Nicole King Strain Limits for Concrete Filled Steel Tubes in AASHTO Seismic Provisions PIs: Mervyn Kowalsky and James Nau RA: Nicole King Project Overview Seismic behavior of reinforced concrete filled steel pipe

More information

Suitability of Different Materials for Stone Column Construction

Suitability of Different Materials for Stone Column Construction Suitability of Different Materials for Stone Column Construction Dipty Sarin Isaac and Girish M. S. Department of Civil Engineering College of Engineering, Trivandrum, Kerala diptyisaac@yahoo.com, girishmadhavan@yahoo.com

More information

PARAMETRIC STUDY OF SHALLOW FOUNDATION BEARING CAPACITY IN CLAYEY SOIL

PARAMETRIC STUDY OF SHALLOW FOUNDATION BEARING CAPACITY IN CLAYEY SOIL International Journal of Civil Engineering and Technology (IJCIET) Volume 9, Issue 10, October 2018, pp. 1223 1230, Article ID: IJCIET_09_10_121 Available online at http://www.iaeme.com/ijciet/issues.asp?jtype=ijciet&vtype=9&itype=10

More information

Question Paper Code : 11410

Question Paper Code : 11410 Reg. No. : Question Paper Code : 11410 B.E./B.Tech. DEGREE EXAMINATION, APRIL/MAY 2011 Fourth Semester Mechanical Engineering ME 2254 STRENGTH OF MATERIALS (Common to Automobile Engineering and Production

More information

USE OF DIPP PILES FOR A NEW SUP BRIDGE IN WEST MELBOURNE

USE OF DIPP PILES FOR A NEW SUP BRIDGE IN WEST MELBOURNE USE OF DIPP PILES FOR A NEW SUP BRIDGE IN WEST MELBOURNE If you want to put a photo on the title slide use this layout with colour photos (delete this box) Michael Wei, Jawad Zeerak & David Barton 8 th

More information

The experience in applying of static load and O-cell pile testing geotechnologies in problematical soil conditions of Astana

The experience in applying of static load and O-cell pile testing geotechnologies in problematical soil conditions of Astana Japanese Geotechnical Society Special Publication International Mini Symposium CHUBU (IMS-CHUBU) The experience in applying of static load and O-cell pile testing geotechnologies in problematical soil

More information

FLEXURAL AND SHEAR STRENGTH OF NON-PRISMATIC REINFORCED HIGH STRENGTH CONCRETE BEAMS WITH OPENINGS AND STRENGTHENED WITH NSM-CFPR BARS

FLEXURAL AND SHEAR STRENGTH OF NON-PRISMATIC REINFORCED HIGH STRENGTH CONCRETE BEAMS WITH OPENINGS AND STRENGTHENED WITH NSM-CFPR BARS International Journal of Civil Engineering and Technology (IJCIET) Volume 6, Issue 9, Sep 2015, pp. 93-103, Article ID: IJCIET_06_09_009 Available online at http://www.iaeme.com/ijciet/issues.asp?jtypeijciet&vtype=6&itype=9

More information

PERFORMANCE OF AFRP CONFINED RC DRIVEN PILES SUBJECTED TO VERTICAL LOADS

PERFORMANCE OF AFRP CONFINED RC DRIVEN PILES SUBJECTED TO VERTICAL LOADS International Journal of Civil Engineering and Technology (IJCIET) Volume 9, Issue 4, April 2018, pp. 1298 1306, Article ID: IJCIET_09_04_146 Available online at http://www.iaeme.com/ijciet/issues.asp?jtype=ijciet&vtype=9&itype=4

More information

TABLE OF CONTENTS FINITE ELEMENT MODELING OF CONCRETE FILLED DOUBLE SKIN

TABLE OF CONTENTS FINITE ELEMENT MODELING OF CONCRETE FILLED DOUBLE SKIN TABLE OF CONTENTS SECTION 1 INTRODUCTION... 1 1.1 Introduction... 1 1.2 Objectives and Scope of Work... 2 1.2.1 Experimental Phase... 2 1.2.2 Analytical Phase... 3 1.3 Outline of the Report... 4 SECTION

More information

FLEXURAL BEHAVIOR OF SELF COMPACTED PERFORATED CONCRETE BEAMS

FLEXURAL BEHAVIOR OF SELF COMPACTED PERFORATED CONCRETE BEAMS International Journal of Civil Engineering and Technology (IJCIET) Volume 9, Issue 11, November 2018, pp. 1185 1191, Article ID: IJCIET_09_11_114 Available online at http://www.iaeme.com/ijciet/issues.asp?jtype=ijciet&vtype=9&itype=11

More information

Application of Vibro Techniques for Infrastructure Projects in India

Application of Vibro Techniques for Infrastructure Projects in India Application of Vibro Techniques for Infrastructure Projects in India Rainer Wegner Contract Manager, Keller Grundbau GmbH, Germany Dr. V.R. Raju Director, Keller Ground Engineering India Pvt Ltd, India

More information

CONFINEMENT CAPACITY OF SQUARE AND CIRCULAR CONCRETE COLUMNS REINFORCED WITH PREFABRICATED CAGE REINFORCEMENT SYSTEM

CONFINEMENT CAPACITY OF SQUARE AND CIRCULAR CONCRETE COLUMNS REINFORCED WITH PREFABRICATED CAGE REINFORCEMENT SYSTEM CONFINEMENT CAPACITY OF SQUARE AND CIRCULAR CONCRETE COLUMNS REINFORCED WITH PREFABRICATED CAGE REINFORCEMENT SYSTEM Rajeena K K 1, Sreepriya Mohan 2 1M.Tech Student, Dept. of Civil Engineering, Sree Narayana

More information

Load capacity of slender reinforced concrete walls governed by flexural cracking strength of concrete

Load capacity of slender reinforced concrete walls governed by flexural cracking strength of concrete Magazine of Concrete Research, 2000, 52, No. 3, June, 169±175 Load capacity of slender reinforced concrete walls governed by flexural cracking strength of concrete J. G. Sanjayan Monash University This

More information

Challenges of Offshore Geotechnical Engineering

Challenges of Offshore Geotechnical Engineering Challenges of Offshore Geotechnical Engineering OCE 582 - Seabed Geotechnics Professor Kate Moran presented by Ursula Hebinck Overview Content of Paper recent developments in offshore site investigation

More information

Mechanical Joint KASHEEN for Large-Diameter Pipe Piles

Mechanical Joint KASHEEN for Large-Diameter Pipe Piles JFE TECHNICAL REPORT No. 8 (Oct. 26) Mechanical Joint KASHEEN for Large-Diameter Pipe Piles AKUTAGAWA Hiroaki *1 TAKANO Kimitoshi *2 TAJIKA Hisakazu *3 Abstract: JFE Group has developed a mechanical joint,

More information

A H M 531 C The Civil Engineering Center

A H M 531 C The Civil Engineering Center Objectives: Measuring the strength of a concrete mix designed at the lab. The strengths to be measured are: Compressive strength. Tensile strength. Flexural strength. Standards: Compressive strength: G.S.

More information

1. SCOPE 2. REFERENCED DOCUMENTS

1. SCOPE 2. REFERENCED DOCUMENTS Illinois Test Procedure 405 Effective Date: January 1, 2016 Determining the Fracture Potential of Asphalt Mixtures Using the Illinois Flexibility Index Test (I-FIT) 1. SCOPE 1.1. This test method covers

More information

EFFECT OF DEEP EXCAVATION SUPPORTED BY CONCRETE SOLIDER PILE WITH STEEL SHEET PILE LAGGING WALL ON ADJACENT EXISTING BUILDINGS

EFFECT OF DEEP EXCAVATION SUPPORTED BY CONCRETE SOLIDER PILE WITH STEEL SHEET PILE LAGGING WALL ON ADJACENT EXISTING BUILDINGS EFFECT OF DEEP EXCAVATION SUPPORTED BY CONCRETE SOLIDER PILE WITH STEEL SHEET PILE LAGGING WALL ON ADJACENT EXISTING BUILDINGS Mostafa Abdou 1 *, Ahamed Rushedy Towfeek 2, Waleed Hassan 3 1 prof. Dr.,

More information

Jet Grouting to Increase Lateral Resistance of Pile Group in Soft Clay

Jet Grouting to Increase Lateral Resistance of Pile Group in Soft Clay GROUND MODIFICATION, PROBLEM SOILS, AND GEO-SUPPORT 265 Jet Grouting to Increase Lateral Resistance of Pile Group in Soft Clay Kyle M. Rollins 1, Matthew E. Adsero 2, and Dan A. Brown 3 1 Prof. Civil &

More information

Mechanical Properties of Block Masonry Units Manufactured From Different Kinds of Recycled Materials

Mechanical Properties of Block Masonry Units Manufactured From Different Kinds of Recycled Materials Mechanical Properties of Block Masonry Units Manufactured From Different Kinds of Recycled Materials Abstract Nart Naghoj Faculty of Engineering Technology, Al Balqa' Applied University, Marka 11134, Amman,

More information

Hybrid FRP-concrete-steel double-skin tubular columns: Cyclic axial compression tests

Hybrid FRP-concrete-steel double-skin tubular columns: Cyclic axial compression tests University of Wollongong Research Online Faculty of Engineering and Information Sciences - Papers: Part A Faculty of Engineering and Information Sciences 212 Hybrid FRP-concrete-steel double-skin tubular

More information

Load Transferring Mechanism and Design Method of Effective Detailings for Steel Tube-Core Concrete Interaction in CFT Columns with Large-Section

Load Transferring Mechanism and Design Method of Effective Detailings for Steel Tube-Core Concrete Interaction in CFT Columns with Large-Section International Journal of High-Rise Buildings September 2018, Vol 7, No 3, 223-232 https://doi.org/10.21022/ijhrb.2018.7.3.223 International Journal of High-Rise Buildings www.ctbuh-korea.org/ijhrb/index.php

More information