PGC5000 Series Process Gas Chromatographs

Size: px
Start display at page:

Download "PGC5000 Series Process Gas Chromatographs"

Transcription

1 PGC5000 Series Process Gas Chromatographs Designed for Reliability and Simplicity PGC5000A Master Controller PGC5000B Smart Oven ABB Inc. Process Analytics 843 N. Jefferson Street Lewisburg, WV, USA Visit

2 Chromatography So Easy Everything You Need At Your Finger Tips! PGC5000A Master Controller Fully functional keypad and mouse touch pad 100 times traditional processing power Intrinsically safe fiber optic connections to Smart Ovens PGC5000B Smart Oven Simple configurations for maximum reliability Easy access to all major components The New PGC5000 Series Reliable Chromatography Made Easy. The PGC5000A Master Controller with new Graphical Driven HMI offers a fully functional keypad and touch pad mouse. Developing, editing and storing analysis methods are now easy. Function block programming is now a thing of the past. Just point and click and drag and drop are all that is required to access and change functions All major analyzer functions are identified on tabs making it easy to access any information. The PGC 5000B Smart Oven is designed for simple applications or making complex applications simple. Smart Ovens are optimized for advanced electronic pressure control; dedicated oven controllers locally execute analytical methods required for the stream's analysis. Multiple Smart Ovens break complex applications into individual sequences producing simpler, more reliable analyzers that are easier to understand and maintain. Flexible, scalable, simple and accessible. ABB Process Analytics Providing gas chromatographs to the Hydrocarbon Processing Industries for over 50 years. For more information, visit or contact AnalyzeIT@us.abb.com. Copyright 2008 ABB Power and productivity for a better world

3 Process Photometers PUV3402 and PIR3502 Applications, Technology and Data Continuous Measurements VistaNET Connectivity Multiple Component Samples Measures Vapor or Liquid Samples Operates in IR, NIR, UV and VIS Regions Fiber Optic Option for NIR Applications Multiple Interference Compensation Capability Analyze IT Field IT Control IT Engineer IT Field IT Inform IT Operate IT Power IT Industrial IT

4 Principle of Operation The PUV3402 and PIR3502 Process Photometers optical path consists of an IR or UV source, a brushless chopper motor, a multichannel filter wheel, lenses, cell with windows, and a solid state IR or UV detector. (See Optical Bench Schematic). L4 Sample Cell L3 L2 L1 The brushless chopper motor rotates the multichannel filter wheel reference and measure filters, alternately and continuously, into and out of the optical path. The lenses, L1 through L4, focus and collimate the source radiation through the sample cell path to the detector. On a multichannel photometer, a reference wavelength is chosen where the stream components have little or no absorbance. The measure wavelength or wavelengths are chosen where the measured components have absorbance. The microprocessor will then use matrix algebra and apply the proper response factor to each filter to eliminate interferences on the desired component and convert the absorbance to a component concentration. Detector Chopper Motor Filter Optical Schematic Advantages of the Design The PUV3402 and PIR3502 Process Photometers use a fixed wavelength filter, single beam, multichannel principle. This design concept offers several advantages: Produces a simple mechanical design that promotes easier service and maintenance. Compensates for obstruction of cell windows. Compensates for source and detector aging. Permits the sample cell to be isolated from the electronics. Enable multicomponent analysis. As illustrated by the Optical Schematic, the simple mechanical design has a single optical path, from the source directly to the detector. The source energy is focused and collimated straight to the detector. It does not require optical mirrors or internal reflections. Source Multiwave TM Process Photometer

5 This enables hardware components to be configured for self-alignment, making all components in the system easy to remove and replace. It also ensures a more reliable and stable long term performance. The cell windows can be obscured by up to 50 % without affecting measurement accuracy, because the single cell, multichannel design measures the ratio of the transmitted energy between the reference and measure wavelengths. Problems normally associated with dual chamber detectors and cells such as gas leaks, optical alignments, vibrations, pitting and corrosion of cell walls, are eliminated by the single beam multichannel design. Also, aging problems typically associated with two sources or two detectors are eliminated. Again, this design concept enhances long term stability and reliability. General Applications ABB PUV3402 and PIR3502 Process Photometers provide on-line measurements of gas or liquid components, in simple or complex process streams for: Process Efficiency Catalyst Protection Product Quality Environmental Concerns Safety Process Control ABB Process Photometers provide reliable performance in the Petrochemical, Chemical, Refining, Gas Processing and Product Pipeline industries. The ABB Process Photometer s single source, single detector design also enables the use of an isolated sample cell. An isolated sample cell has many advantages for on-line process measurements. Contact between flammable or corrosive streams and system electronics is prevented. Access to sample lines is made easier, and cell removal is simplified. Finally, this multichannel evolution of the fixed filter photometer allows measurements in streams where there are several interfering compounds; and it has the ability to measure multiple components in many applications. Left Side: Detector Right Side: Source

6 Spectral Range and Regions Spectral Range: Gas and Liquids with absorbance in the 0.2 to 15 micrometer region of the electromagnetic spectrum. Spectral Regions: Ultraviolet and Visible Near Infrared (Overtone Region) Fundamental Infrared (Rotation-Vibration) Fingerprint Region 200 to 800 nm nm 2.5 to 15 um 8.0 to 15 um The fingerprint region from 8 15 um is very useful because there is a high level of specificity in this region. ABB Process Photometer Field-Proven Applications The following chart is a partial listing of fieldproven applications. These applications are grouped by process. Measured components and key benefits are indexed for each application. Temperature and Pressure Ranges Temperature Ranges: Ambient Sample Cell Operating Temperature Pressure Range: Sample Cell 32 to 113 F (0 45 C) 32 to 392 F (0 200 C) 5 to 500 PSIG ( BAR) standard* *Higher pressures available upon request consult manufacturer.

7 Field-Proven PUV3402 and PIR3502 Process Photometer Applications Process Measurement Benefits Acid Gas Scrubbers Sodium Hydroxide 0 15 % Improved scrubber efficiency and reduced cost Acetic Acid CO % in Reactor Feed Maximize process yield Water 0 20 % in Reactor Outlet Distillation Tower control Water 0 10 % in Drying Column Inlet 2nd half of Distillation Tower control and determining expected life of Drying Column Water ppm in Drying Column Outlet Drying Column efficiency *Methyl Iodide ppm Scrubber efficiency and safety Ammonia CO ppm Catalyst Protection CH % Safety NH % Safety Area Monitoring Ethyl Benzene ppm, Safety, Leak Detection Styrene ppm, Isooctane ppm, Divinylbenzene ppm Crude Unit ASTM color 0 8 Product quality Ethylene Acetylene 0 2 % Hydrogenation reactor inlet continuous control Acetylene % Hydrogenation reactor mid-bed continuous control Ethylene Dichloride CO 0 10 %, CO2 0 5%, Process efficiency and safety and Ethylene 0 5 % *Chlorine ppm in EDC Process efficiency with Sparger System Ethylene Glycol *Percent Transmittance at On-line quality control of Ethylene 4 discrete UV wavelengths Glycol purity Maleic Anhydride CO %, CO %, Reactor Outlet Butane %, and Process Efficiency Maleic Anhydride 0 2 % Butane 0 2 % and Reactor Inlet Water Vapor 0 5 % LEL Control Phosgene CO 0 10 % Process Control *Chlorine ppm Process Control Phosgene ppm Safety Product Pipeline CO ppm Prevent freezing of natural gas Lines Sulfur Recovery H2S %, CO %, Acid Gas Feed Water 0 30 %, THC 0 10 % Forward Control H2S %, NH %, Sour Gas Feed Water 0 30 %, THC 0 10 % Forward Control Vinyl Chloride Water 0 50 ppm in EDC Catalyst protection, corrosion protection of reactors * = UV Application Vinyl chloride ppm, 0 2 % in HCl Condenser efficiency

8 Field-Proven Multicomponent Applications Multicomponent Measurements % toluene; 0 2 % tetrahydrofuran and % LEL of gas mix (3 components) 0 20 % CO; 0 20 % CO2; and 0 5 % CH4 (3 components) 0 55 % propane and 0 20 % propylene (2 components) ppm CH4 and ppm ethane in 100 psig (2 components) ppm CO and ppm CO2 in 200 psig (2 components) ppm fluorobenzene; ppm chlorine; and ppm SO2 in carbon bed vent gas (3 components) 0 5% CO2; 0 5 % CO; 0 1 % toluene and 0 1 % benzene in air oxidation vent (4 components) 0 50 ppm acrylonitrile and 0 50 ppm styrene in air (2 components) 0 50 ppm ethylene oxide and 0 50 ppm propylene oxide in air (2 components) 0 70 % methyl chloride and % methylene chloride (2 components) ppm SO2; ppm NO; ppm NO2 and ppm NOx (4 components) ppm ethane; ppm ethylene and 0 80 % methane (3 components) 0 40% CO2; 0 40 % CO and 0 25 % water vapor in air (3 components) 0 80 % ethylene and 0 15 % CO2 in mixed HC stream as a vapor (2 components) % CO; 0 60 % ethylene; 0 20 % CO2; and 0 5 % ethyl 70 psig (4 components) ppm water and 0 5 % DMSO in monochlorobenzene (2 components) % ethylene; 0 10 % EDC; 0 50 % HCl; and 0 20 % ethyl chloride (4 components) 0 20 % propadiene; 0 40 % methyl acetylene and 0 60 % MAPD (3 components) Water Measurements 0 2% water in phenol ppm water in monochlorobenzene 0 50 ppm water in ethylene dichloride ppm water in 75psig (vapor) % water in ethylene diamine ppm water in vinylidene chloride ppm water in propylene glycol ppm water in methyl ethyl ketone (MEK) ppm water in dimethylacetamide ppm water in allyl chloride % water in acetone ppm water in methanol ppm water in benzene ppm water in toluene diamine ppm water in MEK & alcohols

9 Field-Proven Applications Various Single Component Measurements 1,3 butadiene 0 50 %; in isobutene 1,3 butadiene 0 70 % acetic acid 0 2 %; in acetic anhydride acetylene 0 1 %; in methane; ethane and ethylene acetylene % ammonia ppm; in air cis-2-butene 0 10 %; in butadiene CO2 0 1%; in CH4 and C2H6 CO2 0 1%; in ethane CO ppm; in ethane CO ppm; in propane cyclohexane 0 30 %; in cyclohexanol cyclohexanone ppm; in cyclohexane ethane 0 10 %; in methane and propane ethylene 0 2 %; in ethane H2S 0 15 %; in sour fuel gas hexamethylene imine ppm hydrogen cyanide 0 1 % MEOH 0 20 %; in MTBE/TAME methane 0 6%; in H2 and water vapor methanol 0 40 %; in MTBE methyl bromide ppm in air propane 0 6%; in propylene propylene % total hydrocarbons 0 10 %; in propylene total hydrocarbons ppm; as butene-1 vinyl acetate 0 10 %; in ethylene vinyl acetate 0 20 %; in ethylene UV Field-Proven Applications APHA color 0 50 ASTM color 0 8 ASTM units benzene ppm; in water Bisphenol A 0 25 ppm and ppm; in water chlorine 0 30 %; in propane chlorine 0 10 %; in NaOH+H20 chlorine 0 2 %; in HCl chlorine ppm; SO ppm; in vent gas (2 components) chlorine 0 30 %; in propylene dimethyl aniline ppm; in N2 saturated with water DMAC ppm; in water H2S 0 10 %; in H2 H2S 0 4 %; in N2 Saybolt color -30 to +15 SO ppm SO ppm; in stack gas styrene 0 20 ppm; butadiene in water total aminobenzenes as aniline 0 50 ppm total phenols as 2-chlorophenol 0 25 ppm; in 33 % HCl in H20

10 Partial List of IR and UV Absorbing Compounds The following lists are provided as a general reference for determining potential IR and UV applications. Other considerations will be the remaining stream matrix, stream temperature, stream pressure, and stream phase. The sample must be homogeneous, single phase in order to apply the method. Please provide the needed information on your application to our customer service group so that application engineers can determine the feasibility of your application. Partial List of IR Absorbing Compounds (Potential Measurements) Butadiene (1,3) Butane (n) Carbon dioxide Carbon monoxide Carbon tetrachloride Chloroform Cyanogen Cyclopropane Diazomethane Dichloroethane (1,1 and 1,2) Dichloromethane Dimethyl amine Dimethyl ether Dimethyl hydrazine Ethane Ethyl alcohol Ethyl chloride Freon-13B Freon-14 Freon-C-318 Hydrazine Hydrogen bromide Hydrogen chloride Hydrogen cyanide Hydrogen sulfide Isobutane Methane Methyl alcohol Methyl azide Methyl chloride Methyl mercaptan Nitric Acid Nitric oxide Nitroethane Nitrogen dioxide Nitrogen pentoxide Nitromethane Nitropropane (1 & 2) Nitrosyl chloride Nitrous Oxide Phosgene Propane Propylene Trimethylhydrazine Trimethylamine Vinyl chloride Water Partial List of UV Absorbing Compounds (Potential Measurements) Acetic acid Acetone Ammonia Aniline Anthracene Benzene Bromine Carbon disulfide Carbon tetrachloride Chlorine Chlorine dioxide Chlorophenol (o,m,p) Dioxane Ethylbenzene Ferric chloride Fluorine Furfural Hydrogen peroxide Hydrogen sulfide Iodine Mercury Methyl mercaptan Naphthalene Nickel carbonyl Nitrobenzene Ozone Perchloroethane Phenol Phosgene Pyridine Sodium sulfide Styrene Sulfur Sulfur dioxide Toluene Xylene (o, m, p)

11 Enhanced Applications Capability To enhance the application capability of the Multiwave Photometer, six options are available. Optical Span Filter Temperature and Pressure Compensation Gas Samples Temperature Compensation is available on analyzers that do not have cell heat. It is intended to be used for vapor applications. There are two types of temperature compensation available: Gas Law Compensation Temperature Compensation is based upon the Ideal Gas Law and requires no calibration or set up. An example of where Gas Law Compensation may be useful is for streams at ambient temperature. Empirical Compensation Temperature Compensation is based on experimental data. It requires calibration in the factory lab. Pressure Compensation is used on vapor applications only. It is recommended on suppressed range applications such as % Chlorine. Two types of pressure compensation are available: The optical span filter for the Multiwave Photometer provides the operator with an alternate means of checking the analyzer performance. It is most often used when the process makes it difficult to readily acquire a calibration standard, and when normal calibration methods would be difficult to accomplish or unsafe. Gas Law Compensation Pressure Compensation is based on the Ideal Gas Law and requires no calibration. It is used in selected applications where the gas sample does not have a fine line spectrum. Some common compounds with fine line spectra are carbon monoxide, carbon dioxide, methane, and ammonia. Empirical Compensation Pressure Compensation is based on experimental data. It requires calibration in the factory lab. This type of compensation is recommended on suppressed ranges and on applications susceptible to pressure broadening effects.

12 PFO3372 Fiber Optic Process Photometer This option involves interfacing with the Multiwave Photometer. The Fiber Optic Waveguide eliminates the need to transport sample to the analyzer. With this option, the light is transmitted via one waveguide to the sample. Then, a second waveguide returns the samplemodified light from the sample cell to the detector. Fiber Optics is an effective option in applications where... the sample stream is highly toxic highly corrosive products are analyzed streams are at high temperature streams are at high pressure the sample is at high vacuum the sample needs to remain sanitary a fast response time is required all of the above, or any combination of the above conditions apply Moisture applications such as water in acids, water in methanol, water in hydrocarbons, or hydrocarbons in water are good candidates for the fiber optic option. Applications that require a fast response time, such as monitoring the Lower Explosive Limit (LEL) for hydrocarbons in air, should also be considered. NOTE: Current applications of fiber optics are limited to the UV/Visible ( nm) and NIR ( nm).

13 VN2300 Communications Board The ABB Process Photometer features a VN2300 (formerly VIstaNET) Communications Board option. The VN2300 Remote User Interface (RUI) presents the user with a graphical interface for operation and configuration at a remote PC. The following operations are available via the RUI at the remote PC: Remote Maintenance via modem. Direct calculation of Matrix Coefficients Direct calculation of Linearity Coefficients. Reports, Tables and Applications Data Sheets can be printed and reviewed. Ambient Air Applications The PIR3502 Photometer interfaced with a multireflective long path gas cell can be used in ambient air monitoring applications. Multiple stream Sample Handling Systems combined with the ABB Process Photometer have been used to measure up to 20 points for the detection of toxic gases ppm Acrylonitrile; 0 50 ppm Stryrene 0 25 ppm Ethylene Oxide; 0 25 ppm Propylene Oxide 0 50 ppm Phosgene 0 25 ppm Carbon Tetrachloride; 0 25 ppm Chloroform ppm Divinylbenzene; ppm Ethylbenzene ppm

14 Final Product Blending Optimize your Gasoline and Diesel Blender with Field-proven ABB FT-NIR Technology Final Product Blending Product blending is an important technique used in the refining industry. It is the final stage in the conversion of crude oil into useful fuels. The blender mixes together several streams from various process units to provide fuel that meets government, international or customer specifications. Due to the fact that is the final stage in a refinery process, the optimization of this process is vital. Regardless of how efficient the upstream process units may be, this can be negated if poorly optimized blending produces a substandard fuel. In many respects it is the most important process to optimize and can also bring the maximum benefits in terms of payback. ABB has a vast amount of experience in providing optimization of blending units. The first stage in optimization of the unit is measurement of the properties themselves that are to be optimized. ABB s field-proven FTIR solution can deliver several benefits to the refiner. ABB s reliable, rugged NIR spectrometer is the heart of the analysis system. It uses the latest and most advantageous NIR spectroscopy technique, Fourier Transform Near Infrared (FT-NIR) spectroscopy. The ABB spectrometer is specially designed to operate in process environments so the user does not need to make allowances for a fragile optical instrument.

15 Extractive Analyser Sample System for Final Product Blending Application This spectrometer is housed in a rugged industrial enclosure with hazardous area certification. A fully incorporated temperature controlled sample system provides stable, accurate results. Full Windows process software is included to provide outputs to the plant DCS system (ModBUS, OPC, 4-20mA). ABB will work in close partnership with you to develop customized solutions that meet your specific needs. We offer a wide range of customer support services, including method development, in-house and on-site personnel training, as well as start-up and after-sales service. ABB has been manufacturing FTIR spectrometers and accessories since its foundation in By intensive research and development activities, and through a close partnership with our customers, we have developed a unique expertise in quantitative analysis using FTIR and FT-NIR technology. As a result, we are now the world leader in FTIR and FT-NIR process analyzers. We have an installed base of over 150 currently operational analyzers used in the refining blending field and other refinery applications. We have an accumulative database of approximately 40,000 spectra that can accelerate the implementation of any new blending project. Our expertise and experience means we can confidently claim to be a world leader in this field. Common Operating/Problems Final product blending represents perhaps the most quality-critical aspect of refinery operation. Tight product quality characteristics are defined, and must be met for product release. If these criteria are to be met economically (i.e. with minimized high-cost product giveaway, and by the use of the available blending feedstocks with the lowest cost), then both rapid and accurate on-line product (and feedstock) property measurements are necessary. The measured product qualities are then available in real-time for feeding to an on-line blending optimizer, thus ensuring the most economic blending operation to achieve blend targets. Conventionally, this has been done with a large variety of physical property analyzers and on-line engines to monitor blend properties and octane. These sets of analyzers are extremely expensive, in terms of both capital and ongoing maintenance. Solution / Benefits The ABB range of Process FT-NIR analyzers for on-line gasoline and diesel blend optimization allows for rapid multi-stream and multi-property quality determination of gasoline and gasoil blending components and final product streams. The calibration methodologies employed, and the transferability of calibrations and calibration databases between ABB laboratory analyzers and process blending analyzers, allow for rapid project startup, and minimize the amount of site-specific calibration work needed. For these reasons, the cost of ownership can be significantly reduced, compared with conventional final product blending analysis methods. By accurately measuring final product qualities in real-time, the analyzer will allow feeding any on-line Advanced Blend Control blend optimizer with the required product qualities, will minimize product re-blends and quality giveaway, and will allow the use of lower-cost feedstocks while still meeting final product quality targets. Accurate measurement of blending component qualities as they arrive at the blend header will also allow the optimizer to determine the best achievable blend order. 2

16 Gustave, process manager. Knew where to turn to fuel strong returns. Hero N Gustave is responsible for optimizing the blending margin at a petroleum refinery. A lot rides on the monitoring equipment he selected. Substandard blends mean additional re-blend costs; over-target blends mean reduced profit margins. With their excellent reputation for realtime, on-line gasoline blend optimization, ABB s FT-NIR refinery process solutions caught Gustave s attention. And once installed, the millions of dollars in savings ABB s solution generated caught the attention of Gustave s superiors. FT-IR Optimizing Productivity. Learn how ABB Analytical helped Gustave overcome technical challenges.

17 Gustave, process manager. Knew where to turn to fuel strong returns. Primary responsibilities: 1. Maximize refinery s blending margin. 2. Meet final blended product qualities required by legislation. 2. Avoid shipping over-target products or incurring re-blend costs by blending sub-standard gasoline. The challenge Gustave needed an on-line quality monitoring solution to enable consistent, on-target blends, using the most economical blending recipe from his pool of blending components. ABB s FT-NIR analyzers have an excellent reputation for realtime, on-line gasoline blend optimization. However, Gustave was concerned calibration models could be difficult to develop and maintain. Custom calibrations used by on-line analyzers must be developed in the laboratory on a different instrument. Any instabilities or photometric non-linearities in the instruments make it difficult to develop reliable calibrations and transfer these calibrations directly from the laboratory analyzer to the on-line analyzers. The solution With easy-to-use software, ABB s laboratory analyzer (MB3600-HP10) simplifies hydrocarbon sample determination and calibration development. Their analyzer also has pre-defined calibrations for blended gasoline, diesel, reformate and naphtha. It was crucial to transfer the calibrations developed in the lab directly to the on-line process analyzers. ABB s manufacturing methods ensure all their laboratory and process FT-NIR analyzers provide identical absorbance spectra. This guarantees calibration transferability from lab to process without additional calibration effort or data manipulation. Finally, ABB offers a full range of custom calibration modeling services and application support to their customers a great help in getting started. Why I chose ABB FT-NIR analyzers: Reliable real-time process monitoring with no drift ABB s analyzers are robust and deliver consistently reliable results. Calibration transfer between instruments is also guaranteed. Simplified analysis and calibration development in the lab With easy-to-use software and pre-calibrated analytical procedures, the MB3600-HP10 laboratory analyzer simplifies in-lab hydrocarbon sample determination. Additional custom calibrations can easily be developed for a wide range of products. Minimal preventive maintenance All ABB FT-NIR analyzers are permanently aligned. The new MB3600-HP10 is fitted with leading-edge long-life solid-state laser metrology which completely eliminates the need for laser replacement; on-line FT-NIR analyzers feature user-replaceable modular components for easy preventative maintenance in the field. Local technical support We used a locally certified ABB partner for installing and commissioning the on-line analyzers. Comprehensive calibration modeling and training services ABB offers a full range of custom modeling services and chemometrics training for customers. The results ABB worked closely with our personnel to define the optimal solution. Six months after our blending optimization project received the go-ahead, two on-line FT-NIR analyzers were installed. In the meantime, custom calibration models were developed and validated in the lab using the MB3600-HP10. After a short period of QMI validation, the on-line analyzers were qualified for blend optimization and product release. My control engineer said without the in-blend optimization using validated on-line blend quality inputs from process FT-NIR, the required multiple quality constraints could never have been met simultaneously. Gustave s refinery director estimates using ABB s advanced process control on their blend operations adds at least $6 million per year to the refinery s bottom line. Gustave The MB3600-HP10 Laboratory Analyzer Hardware Software Accessories for both QA/QC analysis and chemometrics development Pre-defined calibrations for blended gasoline, diesel, reformate and naphtha. For further information regarding ABB products and services visit * Each ABB Hero Story is a real business case. In order to maintain confidentiality, the name of the hero has been changed and the company name is not mentioned. ABB Analytical 585 Charest Blvd East, suite 300 Quebec, (Quebec) G1K 9H4 Canada Phone: (North America) ftir@ca.abb.com Web: Printed in Canada 07/09 Copyright 2009 by ABB. All Rights Reserved. Registered Trademark of ABB TM Trademark of ABB

MAX300-AIR PRODUCT NOTE. Ambient Air Monitoring Flare Gas Analysis Industrial Health and Safety. Environmental Mass Spectrometer

MAX300-AIR PRODUCT NOTE. Ambient Air Monitoring Flare Gas Analysis Industrial Health and Safety. Environmental Mass Spectrometer MAX300-AIR Environmental Mass Spectrometer PRODUCT NOTE Ambient Air Monitoring Flare Gas Analysis Industrial Health and Safety Introducing the MAX300-AIR Be Safe, Be Clean, Be Compliant Mass spectrometry

More information

Draeger-Tubes and accuro Pump

Draeger-Tubes and accuro Pump Draeger-Tubes and accuro Pump Trusted Technology that s ahead of its time Accurate Easy to read Flexible Fast Specific Easy to use Maintenance free Multi-Gas Detector accuro pump One handed operation What

More information

3M Meridian Sensor Specifications

3M Meridian Sensor Specifications 3M Table of contents sensor specification guide Combustible sensors 3 Combustible Catalytic Bead Sensor 4 Common K-Factors (Relative to Methane Toxic sensors 5 Ammonia (NH 3 Sensor 6 Bromine, High RH (RS

More information

Industry Standards & Definitions

Industry Standards & Definitions NEMA Designation Underwriters Laboratories Inc. UL 50 and UL 508 Canadian Standards Association CSA Standard C22.2 No 94 404 90 ADALET NEMA Designation Underwriters Laboratories Inc. UL 50 and UL 508 Canadian

More information

Guide to Safe Handling & Storage of Hazardous Materials

Guide to Safe Handling & Storage of Hazardous Materials Guide to Safe Handling & Storage of Hazardous Materials I. ACIDS VI. PYROPHORICS II. BASES (CAUSTICS) VII. PEROXIDE FORMING CHEMICALS III. FLAMMABLES VIII. TOXIC CHEMICALS IV. OXIDIZERS IX. CARCINOGENS

More information

Appendix F: Hazardous Gases and Vapors

Appendix F: Hazardous Gases and Vapors Appendix F: Hazardous Gases and Vapors The following pages contain excerpts from the National Fire Protection Association (NFPA) publication NFPA 497M Classification of Gases, Vapors, and Dusts for Electrical

More information

Obstructed or Non-Vertical Oriented Toxic Air Pollutant Permitting Emission Rates (TPER) Toxicants

Obstructed or Non-Vertical Oriented Toxic Air Pollutant Permitting Emission Rates (TPER) Toxicants 15A NCAC 02Q.0711 EMISSION RATES REQUIRING A PERMIT (a) A permit to emit toxic air pollutants shall be required for any facility, excluding sources exempt from evaluation by 15A NCAC 02Q.0702, if one or

More information

Carcinogens. lb/yr. lb/day

Carcinogens. lb/yr. lb/day 15A NCAC 02Q.0711 EMISSION RATES REQUIRING A PERMIT (a) A permit to emit toxic air pollutants shall be required for any facility where one or more emission release points are obstructed or non-vertically

More information

Applications / Compatibility Guide

Applications / Compatibility Guide Applications / Compatibility Guide Hunsworth Lane, Cleckheaton, West Yorkshire. BD19 3UJ Telephone: +44 1274 878787 Fax: +44 1274 862588 e.mail: smith@novussealing.com Website: www.novussealing.com If

More information

Measuring trace impurities in HyCO, regeneration hydrogen and inert gases Los Gatos Research (LGR)

Measuring trace impurities in HyCO, regeneration hydrogen and inert gases Los Gatos Research (LGR) Application note AN/ANALYTICAL/001 EN Rev. D Measuring trace impurities in HyCO, regeneration hydrogen and inert gases Los Gatos Research (LGR) The new LGR-ICOS TM laser process analyzer from ABB provides

More information

THIS IS A REAL-TIME MACHINE. duvastechnologies.com

THIS IS A REAL-TIME MACHINE. duvastechnologies.com THIS IS A REAL-TIME MACHINE duvastechnologies.com LATER IS TOO LATE Let s look at Benzene! Benzene is a highly flammable liquid, which occurs naturally in crude oil, natural gas, some ground waters and

More information

RYTON (PPS) Chemical Compatibility & Chemical Resistance Chart

RYTON (PPS) Chemical Compatibility & Chemical Resistance Chart RYTON (PPS) Chemical Compatibility & Chemical Resistance Chart Explanation of Footnotes 1. Satisfactory to 72 F (22 C) 2. Satisfactory to 120 F (48 C) Ratings -- Chemical Effect A = Excellent. B = Good

More information

ETHYLENE PLANT DRY CRACKED GAS Product Code 54801

ETHYLENE PLANT DRY CRACKED GAS Product Code 54801 SS2100 WATER IN ETHYLENE PLANT DRY CRACKED GAS Product Code 54801 KEY FEATURES Extremely fast analysis time 1 second updates possible Non-contact laser and detector - Reliable Tunable Diode Laser lasts

More information

Measuring trace impurities in HyCO, regeneration hydrogen and inert gases Los Gatos Research (LGR)

Measuring trace impurities in HyCO, regeneration hydrogen and inert gases Los Gatos Research (LGR) ABB MEASUREMENT & ANALYTICS APPLICATION NOTE Measuring trace impurities in HyCO, regeneration hydrogen and inert gases Los Gatos Research (LGR) The new LGR-ICOS TM laser process analyzer from ABB provides

More information

MAX300-RTG PRODUCT NOTE. Real-Time Gas Analysis Process Automation and Control Product Quality Analysis. Industrial Process Mass Spectrometer

MAX300-RTG PRODUCT NOTE. Real-Time Gas Analysis Process Automation and Control Product Quality Analysis. Industrial Process Mass Spectrometer MAX300-RTG Industrial Process Mass Spectrometer PRODUCT NOTE Real-Time Gas Analysis Process Automation and Control Product Quality Analysis www.extrel.com Introducing the MAX300-RTG Optimize Your Manufacturing

More information

APPLICATION NOTE. UOP : Analysis of Trace CO and CO 2 in bulk H 2 and Light Gaseous Hydrocarbons by GC

APPLICATION NOTE. UOP : Analysis of Trace CO and CO 2 in bulk H 2 and Light Gaseous Hydrocarbons by GC UOP 63-13: Analysis of Trace CO and CO 2 in bulk H 2 and Light Gaseous Hydrocarbons by GC Fast Analysis in

More information

SENSOR SELECTION GUIDE

SENSOR SELECTION GUIDE SENSOR SELECTION GUIDE TOXIC AND COMBUSTIBLE GAS MONITORS (Includes gas listings with TLV-TWA, STEL, IDLH, LEL, and UEL for most gases) INTERNATIONAL SENSOR TECHNOLOGY The Leader In Gas Detection Since

More information

15A NCAC 02B.0269 is amended with changes without notice pursuant to G.S. 150B-21.5(a)(3) as follows: SECTION.0600 RIPARIAN BUFFER RESTORATION FUND

15A NCAC 02B.0269 is amended with changes without notice pursuant to G.S. 150B-21.5(a)(3) as follows: SECTION.0600 RIPARIAN BUFFER RESTORATION FUND 1 8 9 10 11 1 1 1 1 1 1 18 19 0 1 8 9 0 1 1A NCAC 0B.09 is amended with changes without notice pursuant to G.S. 10B-1.(a)() as follows: SECTION.000 RIPARIAN BUFFER RESTORATION FUND 1A NCAC 0B.09 1A NCAC

More information

X-Change Gas Sensor Cartridges. PolyGard 2 SC2

X-Change Gas Sensor Cartridges. PolyGard 2 SC2 X-Change Gas Sensor Cartridges Specifications subject to change without notice. USA 190226 Page 1 of 5 DESCRIPTION The sensor cartridge includes a high performance sensing element (electrochemical for

More information

DIVISION OF WASTE MANAGEMENT RESIDENTIAL VAPOR INTRUSION SCREENING CONCENTRATIONS (March, 2016)

DIVISION OF WASTE MANAGEMENT RESIDENTIAL VAPOR INTRUSION SCREENING CONCENTRATIONS (March, 2016) Note: The Residential screening level below or site specific screening concentrations (utilizing site specific attenuation and exposure factors) can be used. In either case the site s remedy must include

More information

MiniWarn. Fits Your Application. Intelligent. Rugged. Flexible. Ergonomic. Easy to use. Multi-Gas Instrument

MiniWarn. Fits Your Application. Intelligent. Rugged. Flexible. Ergonomic. Easy to use. Multi-Gas Instrument Fits Your Application Intelligent Rugged Flexible Ergonomic Easy to use Multi-Gas Instrument Draeger: First in detection Since 1937, when we introduced our first detector tube, Dräger has been the world

More information

Special Applications. Special Applications. ENVIRONMENTAL MONITORING. EPA Instrumental Test Methods as Defined by 40 CFR Part 60

Special Applications. Special Applications.   ENVIRONMENTAL MONITORING. EPA Instrumental Test Methods as Defined by 40 CFR Part 60 EPA Instrumental Test Methods EPA Instrumental Test Methods as Defined by 40 CFR Part 60 # EPA Method Test Method Determines Components Tested Zero Gas* 3A* O 2 % & CO 2 % O 2 % &/or CO 2 % in N 2 or mixtures

More information

MB3600. Versatile FT-NIR analyzer designed for your industry. The most reliable FT-NIR specifically designed for QA / QC.

MB3600. Versatile FT-NIR analyzer designed for your industry. The most reliable FT-NIR specifically designed for QA / QC. MB3600 Versatile FT-NIR analyzer designed for your industry. The most reliable FT-NIR specifically designed for QA / QC. MB3600 FT-NIR Spectrometer for your industry Our industry needs versatility and

More information

SCOTTY Brand Transportables Convenient, Cost-Effective Calibration Gases

SCOTTY Brand Transportables Convenient, Cost-Effective Calibration Gases SCOTTY Brand Transportables Convenient, Cost-Effective Calibration Gases Now with products engineered expressly for Laboratory and Industrial Hygiene and Safety Applications. SCOTTY products are easy to

More information

Corrections to Static Book. Page 18 figure 2-5: delete acetone from figure (I can t do this electronically)

Corrections to Static Book. Page 18 figure 2-5: delete acetone from figure (I can t do this electronically) Corrections to Static Book Page 18 figure 2-5: delete acetone from figure (I can t do this electronically) Page 41 Note 1 ninth line: delete second period after Figure 2-6.5 Page 43 Section 2-6.6: replace

More information

TDLAS. Application Note. Use of TDLAS Based Analyzers for Real-Time Process Control in Ethylene Oxide Production PROCESS INSTRUMENTS

TDLAS. Application Note. Use of TDLAS Based Analyzers for Real-Time Process Control in Ethylene Oxide Production PROCESS INSTRUMENTS PROCESS INSTRUMENTS Application Note Use of Based Analyzers for Real-Time Process Control in Ethylene Oxide Production Ethylene oxide (EO), which is derived from ethylene, is a high volume chemical feed

More information

A World of Gases. A Single Transmitter. UniSens. Universal 2-Wire Gas Transmitter...

A World of Gases. A Single Transmitter. UniSens. Universal 2-Wire Gas Transmitter... A World of Gases A Single Transmitter. UniSens. Universal 2-Wire Gas Transmitter... ATI Presents A Simpler Approach To Toxic Gas Detection. One Transmitter Is All You Need. Time was, monitoring multiple

More information

Technical Note TN-114 rev 16 wy/wh.11-04

Technical Note TN-114 rev 16 wy/wh.11-04 Sensor Specifications And Cross-Sensitivities Technical Note TN-114 Note: All performance specifications are subject to change without notice and are based upon conditions at 68 o F (20 o C), 50% relative

More information

Real-Time Measurement for Unparalleled Safety and Control

Real-Time Measurement for Unparalleled Safety and Control REFINERY SOLUTIONS Real-Time Measurement for Unparalleled Safety and Control Analyzer solutions to reduce process downtime, ensure safe operation, and optimize production efficiency in refinery operations.

More information

Ground Water Screening Level (GWSL) 1,2 ug/l TCR = 1.0E-05/HQ =0.2. Sub-slab and Exterior Soil Gas Screening Level (SGSL) 1,2.

Ground Water Screening Level (GWSL) 1,2 ug/l TCR = 1.0E-05/HQ =0.2. Sub-slab and Exterior Soil Gas Screening Level (SGSL) 1,2. Note: The non-residential screening level below or site specific screening concentrations (utilizing site specific attenuation and exposure factors) can be used. In either case the site s remedy must include

More information

TDLAS. Application Note. Tunable Diode Laser Absorption Spectroscopy (TDLAS) for Carbon Dioxide Measurements In Natural Gas Processing

TDLAS. Application Note. Tunable Diode Laser Absorption Spectroscopy (TDLAS) for Carbon Dioxide Measurements In Natural Gas Processing PROCESS INSTRUMENTS Application Note Tunable Diode Laser Absorption Spectroscopy () for Carbon Dioxide Measurements In Natural Gas Processing Introduction Natural gas is one of the world s most important

More information

Preferred. Steel, Epoxy Powder Coated. Satisfactory. Limited

Preferred. Steel, Epoxy Powder Coated. Satisfactory. Limited Corrosion Resistance We manufactures enclosures from a wide range of materials, offering varying degrees of resistance against chemical corrosion. All materials are affected by corrosion in some manner.

More information

Process Gas Monitoring In Petroleum Refineries

Process Gas Monitoring In Petroleum Refineries Application Data Sheet ADS 103-2911AA01 July, 2005 Application Data Process Gas Monitoring In Petroleum Refineries APPLICATION Emerson offers several Rosemount Analytical gas analyzer technologies to meet

More information

Stack Sampling. requires airflow through the sampling probe to be at the same rate as that flowing in the waste gas stream isokinetic

Stack Sampling. requires airflow through the sampling probe to be at the same rate as that flowing in the waste gas stream isokinetic Stack Sampling emissions associated with combustion, velocity and temperature may be much higher than ambient conditions - measure to correct to standard conditions Velocity data determined from pressure

More information

Hydrocarbon Processing Industry Gas Chromatographs. Standard GC Analyzer Solutions

Hydrocarbon Processing Industry Gas Chromatographs. Standard GC Analyzer Solutions Hydrocarbon Processing Industry Gas Chromatographs Standard GC Analyzer Solutions Scion Instrument s GC Analyzer specialists have the knowledge and experience to provide pre-configured gas chromatographic

More information

Mach-RGA. The Fast Refinery Gas Analyzer. Analyzer

Mach-RGA. The Fast Refinery Gas Analyzer. Analyzer Mach-RGA The Fast JAS Mach-RGA Refinery gas is used as a fuel gas or as feedstock for further chemical processing. US EPA Title V Permit requires operators to monitor and report the composition of refinery

More information

1st Pass 1st Pass 1st Pass 2nd Pass 2nd Pass. 1st Pass 1st Pass 1st Pass 2nd Pass 2nd Pass

1st Pass 1st Pass 1st Pass 2nd Pass 2nd Pass. 1st Pass 1st Pass 1st Pass 2nd Pass 2nd Pass Gas Adsorbent Media Selection Guide Selection by Application Type Note 1: Many applications with heavy loading levels and mixed contaminants may require the use of two or more types of adsorbent medias

More information

MB3000-PH. FT-IR Spectrometer for the Pharmaceutical Industry Designed for QA/QC, Formulation, Research and Development Laboratory Applications.

MB3000-PH. FT-IR Spectrometer for the Pharmaceutical Industry Designed for QA/QC, Formulation, Research and Development Laboratory Applications. MB3000-PH FT-IR Spectrometer for the Pharmaceutical Industry Designed for QA/QC, Formulation, Research and Development Laboratory Applications. MB3000-PH FT-IR Spectrometer for the Pharmaceutical Industry

More information

GAS DETECTION SYSTEMS

GAS DETECTION SYSTEMS PRODUCT GUIDE SENSING SOLUTIONS The quality of the air we breathe and the water we drink is of basic concern to everyone. Analytical Technology is committed to developing and improving the sensing technologies

More information

AGC NovaPRO Process Gas Chromatograph Refinery Applications

AGC NovaPRO Process Gas Chromatograph Refinery Applications AGC NovaPRO Process Gas Chromatograph Refinery Applications Head Quarters Address: Unit 2, Shannon Free Zone West, Shannon, Co. Clare, Ireland T: +353 61 471632 F: +353 61 471042 E: sales@agc-instruments.com

More information

TECH SERVICES DOCUMENT (Rev 6/12/2008) Page 1 of 6

TECH SERVICES DOCUMENT (Rev 6/12/2008) Page 1 of 6 Page 1 of 6 3607-78-1 1,1,1,3,3,3-Hexachloropropane 71-55-6 1,1,1-Trichloroethane 107-06-2 1,2-Dichloroethane 78-87-5 1,2 Dichloropropane 73 3.2 107-21-1 1,2-Dihydroxyethane

More information

Calibration gas cylinders Calibration gas cylinders for the calibration or the periodical checkings of the gas detectors

Calibration gas cylinders Calibration gas cylinders for the calibration or the periodical checkings of the gas detectors Calibration gas cylinders Calibration gas cylinders for the calibration or the periodical checkings of the gas detectors KEY FEATURES and BENEFITS Etensive range of standard and custom mitures Blended

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: (Hereinafter called the Organization) and hereby declares

More information

Fpollutant-free zero air for analytical

Fpollutant-free zero air for analytical Ambient Air Quality Monitoring System AQMS-100 Zero Air Generator PI AQMS-100 provides ultra pure Fpollutant-free zero air for analytical purpose. Remote monitoring and configuration can also be achieved

More information

GTL. and Edited and Revised 2016 by H M Fahmy

GTL. and Edited and Revised 2016 by H M Fahmy GTL Taken Partly from the Internet and Edited and Revised 2016 by H M Fahmy STEPS TO GET OIL FROM SEA OR EARTH SEISMIC SHOOTING SEISMIC INTERPRETATION ANALYSIS OF SAMPLES PREPARATION OF RIG DRILLING OIL

More information

Process Analytics Using Quantum Cascade Laser

Process Analytics Using Quantum Cascade Laser Process Analytics Using Quantum Cascade Laser YT Koh Director Analyzers & Solutions Standards Certification Education & Training Publishing Conferences & Exhibits Presenter Koh Yee Tiong Yee Tiong (YT),

More information

SENSOR SPECIFICATIONS AND CROSS-SENSITIVITIES

SENSOR SPECIFICATIONS AND CROSS-SENSITIVITIES SENSOR SPECIFICATIONS AND CROSS-SENSITIVITIES Disclaimer: Technical Note TN-114 presents specifications, cross-sensitivities, and calibration information on select RAE Systems sensors. All specifications

More information

Sensor Technologies used in Portable Gas Monitors. HA University

Sensor Technologies used in Portable Gas Monitors. HA University Sensor Technologies used in Portable Gas Monitors HA University Multi-gas & Single-gas Monitors Today s gas monitoring equipment has come a long way from the miner s canary. Workers need to have a personal

More information

Calibration equipment

Calibration equipment Calibration equipment Permanent laboratory Analitycal instruments: at LAT Centre GAS CHROMATOGRAPHS AND ANALYZERS WITH DETECTORS From to TCD and FID (* 1 10-6 50 10-2 2% 50 10-2 99.5 10-2 0.1% Ethane (C

More information

Getting the most from your 4 gas monitor. Terri A. Pearce, PhD Emily R. T. Schmick, MSPH, CIH

Getting the most from your 4 gas monitor. Terri A. Pearce, PhD Emily R. T. Schmick, MSPH, CIH Getting the most from your 4 gas monitor Terri A. Pearce, PhD Emily R. T. Schmick, MSPH, CIH NIOSH Disclaimer: The findings and conclusions in this report are those of the author(s) and do not necessarily

More information

Detector Tube Selection Guide. March, 2013 (Rev. Q)

Detector Tube Selection Guide. March, 2013 (Rev. Q) Detector Selection Guide March, 2013 (Rev. Q) www.sensidyne.com Table of Contents Page Detector s... 4 12 Compressed Breathing s... 13 Ion s... 13 TWA s... 13 Numerical Listing... 14-16 Kits and Accessories...

More information

ABB MEASUREMENT & ANALYTICS DATA SHEET. PGC5007 Total sulfur analyzer

ABB MEASUREMENT & ANALYTICS DATA SHEET. PGC5007 Total sulfur analyzer ABB MEASUREMENT & ANALYTICS DATA SHEET PGC5007 Total sulfur analyzer 2 P G C 5 0 0 7 TOTA L S U L F U R A N A LY Z E R D S/ P G C 5 0 0 7- E N R E V. A Measurement made easy Online ASTM method D7041-04

More information

Detector Tube Selection Guide. March, 2011 (Rev. Q)

Detector Tube Selection Guide. March, 2011 (Rev. Q) Detector Tube Selection Guide March, 2011 (Rev. Q) www.sensidyne.com Page Detector Tubes... 4 12 Compressed Breathing Tubes... 13 Ion Tubes... 13 TWA Tubes... 13 Numerical Tube Listing... 14-16 Kits and

More information

Gas Sampling Bags. Cost-Effective Alternatives for Air Sampling. Restek Air

Gas Sampling Bags. Cost-Effective Alternatives for Air Sampling. Restek Air Restek Air Gas Sampling Bags Cost-Effective Alternatives for Air Sampling Ideal for whole air sampling at ppb-ppm levels. Select from Tedlar, ALTEF, and multi-layer foil bags in a wide range of sizes.

More information

Greenhouse Gas Measurement Technology

Greenhouse Gas Measurement Technology Greenhouse Gas Measurement Technology Michael Corvese Thermo Fisher Scientific March 25, 2010 Agenda Introduction GHG Regulatory Current Methods Infrared Spectroscopy GC FID Emerging Methods Laser-Based

More information

Measurement made easy

Measurement made easy ABB MEASUREMENT & ANALYTICS WHITE PAPER Hydrofluoric acid alkylation (HFU) unit optimization The use of robust pre-calibrated on-line analyzer technology for the measurement of HF acid purity This white

More information

ATTACHMENT 3. Firestone Geomembrane Chemical Resistance Chart

ATTACHMENT 3. Firestone Geomembrane Chemical Resistance Chart ATTACHMENT 3 Firestone Geomembrane Chemical Resistance Chart Firestone Geomembrane exposure to these chemicals causes no swelling, softening or surface deterioration of the membrane. Acetamide Acryimide

More information

Thomas G. Braga Manager, Research and Development. SulfaTreat, a Business Unit of M I L.L.C. A Smith/Schlumberger Company

Thomas G. Braga Manager, Research and Development. SulfaTreat, a Business Unit of M I L.L.C. A Smith/Schlumberger Company Thomas G. Braga Manager, Research and Development SulfaTreat, a Business Unit of M I L.L.C. A Smith/Schlumberger Company Who is SulfaTreat? A World Leader in H 2 S Removal for More than a Decade Today

More information

SCOTT Method TO-14A/15/17

SCOTT Method TO-14A/15/17 SCOTT Method TO-14A/15/17 Calibration Standards Benefits and Features SCOTT technical expertise in engineering Method 14A/15/17, HAPS and TIC calibration standards, sulfur mixes and vapor intrusion products

More information

Hazardous Chemicals, Dangerous Goods and Explosives Storage and Transport Procedure

Hazardous Chemicals, Dangerous Goods and Explosives Storage and Transport Procedure Hazardous Chemicals, Dangerous Goods and Explosives Storage and Transport Procedure Related Policy Work Health and Safety Policy Responsible Officer Executive Director Human Resources Approved by Executive

More information

Measurement made easy

Measurement made easy ABB MEASUREMENT & ANALYTICS WHITE PAPER Naphtha Steam Cracking (NSC) unit optimization The use of robust on-line analyzer technology for the real-time optimization of steam-cracking furnace operation This

More information

material chemical Note ) This data is subject to change for update of specifications and availability of newer formation.

material chemical Note ) This data is subject to change for update of specifications and availability of newer formation. Note: The following tables are intended to serve only as your reference of s, and are not intended to using s, please exercise your own judgment based on the verification with your real machine. For s

More information

Chemical Resistance and Material Selection Guide for Drum Pumps

Chemical Resistance and Material Selection Guide for Drum Pumps esistance and Material Selection Guide for Drum Pumps The information in the following guide lists the corrosion resistance of four materials used in the drum pump outer tubes. Additional wetted materials

More information

???? Spot Check Measurement Simple, accurate, reliable

???? Spot Check Measurement Simple, accurate, reliable Spot Check Measurement Simple, accurate, reliable???? Always a step ahead The development of a new measurement system For more than 60 years, Dräger Sicherheitstechnik GmbH has developed, produced, and

More information

Sensor Specifications and CroSS- Sensitivities

Sensor Specifications and CroSS- Sensitivities Sensor Specifications and CroSS- Sensitivities Disclaimer: Technical Note TN-114 presents specifications, cross-sensitivities, and calibration information on select RAE Systems sensors. All specifications

More information

Photo by Rob Kerr. Ozone enhancement in Western U.S. wildfire plumes at the Mt. Bachelor Observatory: The Role of NOx

Photo by Rob Kerr. Ozone enhancement in Western U.S. wildfire plumes at the Mt. Bachelor Observatory: The Role of NOx Photo by Rob Kerr Ozone enhancement in Western U.S. wildfire plumes at the Mt. Bachelor Observatory: The Role of NOx Pao Baylon, University of Washington, 18 June 2014 Outline Wildfire chemistry O 3 enhancement

More information

Appendix A Analytical Methods for Air Sampling

Appendix A Analytical Methods for Air Sampling Analytical s Air Sampling Acenaphthene TO-13A PUF / XAD 10 0.4 Acenaphthylene TO-13A PUF / XAD 10 0.35 Acetaldehyde Acetone TO-15 Can or Bag 1.9 0.47 Acetonitrile TO-15 Can or Bag 1.7 0.12 Acetophenone

More information

Chemical resistance of Saniclad PVC products

Chemical resistance of Saniclad PVC products resistance of Saniclad PVC products The table that appears in the following pages lists the resistance of SAI CLAD PVC sheets to a number of commonly encountered chemicals and other corrosive media at

More information

Chemical Resistance and Material Selection Guide for FTI Drum Pumps

Chemical Resistance and Material Selection Guide for FTI Drum Pumps esistance and Material Selection Guide for FTI Drum Pumps The information in the following guide lists the corrosion resistance of four materials used in FTI drum pump outer tubes. Additional wetted materials

More information

Air Quality (VOC) Transmitters for Duct Mounting. Features. Ordering QDT QDT S QDT D

Air Quality (VOC) Transmitters for Duct Mounting. Features. Ordering QDT QDT S QDT D Features Used to determine the air quality, based on a mixed gas sensor (VOC sensor) To measure the air quality in offices, hotels, meeting rooms, convention centres, schools, airports, apartments, stores,

More information

ABSORPTION MEASURING INSTRUMENT

ABSORPTION MEASURING INSTRUMENT Applications UV absorption measurement (DOC-monitoring) Hazen color measurement Color measurement in beer, sugar, hydrocarbons, etc. Concentration measurement of electrolytes, ClO 2, Cl 2, O 3, etc. Monitoring

More information

INDUSTRIAL MEASUREMENTS USING FTIR GAS ANALYZER

INDUSTRIAL MEASUREMENTS USING FTIR GAS ANALYZER 1 INDUSTRIAL MEASUREMENTS USING FTIR GAS ANALYZER Brief introduction, thoughts and experiences MOTIVATION FOR EMISSION MEASUREMENTS 2 Condition of environment Air quality Emission studies Dispersion models

More information

Continous Emission Monitoring: Methods, Regulations and QA/QC. Anders Arvidsson, Opsis AB, Sweden

Continous Emission Monitoring: Methods, Regulations and QA/QC. Anders Arvidsson, Opsis AB, Sweden Continous Emission Monitoring: Methods, Regulations and QA/QC Anders Arvidsson, Opsis AB, Sweden OPSIS? OPSIS is a Swedish company which develops, manufactures and supplies total solutions for Ambient

More information

OREGON Environmental Laboratory Accreditation Program ORELAP Fields of Accreditation RJ Lee Group, Inc./Columbia Basin Analytical Laboratories

OREGON Environmental Laboratory Accreditation Program ORELAP Fields of Accreditation RJ Lee Group, Inc./Columbia Basin Analytical Laboratories MATRIX Reference Code Analyte Code Description Air EPA TO-11A 10311805 Determination of Formaldehyde in Ambient Air Using Adsorbent Cartridge Followed by High Performance Liquid Chromatography (HPLC) 6110

More information

CANADA UNISEARCH founded in 1980

CANADA UNISEARCH founded in 1980 CANADA UNISEARCH founded in 1980 Piergiorgio Viglino Sales and Service Manager Europe and the Middle East pviglino@unisearch-associates.com Tunable Diode Laser (TDL) Absorption Spectrometry LasIR TM TDL

More information

Agilent 8355 Sulfur Chemiluminescence Detector REIMAGINED. REDESIGNED.

Agilent 8355 Sulfur Chemiluminescence Detector REIMAGINED. REDESIGNED. Agilent 8355 Sulfur Chemiluminescence Detector REIMAGINED. REDESIGNED. AGILENT 8355 SULFUR CHEMILUMINESCENCE DETECTOR (SCD) THE ONLY INTEGRATED SYSTEM FOR LOW-LEVEL SULFUR ANALYSIS Why did Agilent reimagine

More information

Carbonyl compounds and VOCs analysis from vehicle exhaust: Conventional and alternative methods of detection, analysis and quantification

Carbonyl compounds and VOCs analysis from vehicle exhaust: Conventional and alternative methods of detection, analysis and quantification WLTP sub group_2 Additional pollutants Vienna October 2010 1 Carbonyl compounds and VOCs analysis from vehicle exhaust: Conventional and alternative methods of detection, analysis and quantification Definitions:

More information

Introduction to Chemical Plant Design Life Cycle

Introduction to Chemical Plant Design Life Cycle Introduction to Chemical Plant Design Life Cycle Process Safety Consideration Chemical Plant Design A project/endeavour/task to determine the structure of a process to produce a product in the way that

More information

CHEMICALS ALCOHOLS BASES

CHEMICALS ALCOHOLS BASES ACIDS Acetic Acid Acetic Acid Glacial Acetic Acid, Acrylic Acid Aqua Regia Benzene Sulfonic Acid Benzoic Acid Boric Acid Carbolic Acid Carbonic Acid Chloroacetic Acid Chlorosulfonic Acid D D D Chromic

More information

D-fenceline TM & OPS. Innovation with Integrity. Real-Time Monitoring System for Fugitive Emissions Management FT-IR

D-fenceline TM & OPS. Innovation with Integrity. Real-Time Monitoring System for Fugitive Emissions Management FT-IR D-fenceline TM & OPS Real-Time Monitoring System for Fugitive Emissions Management Innovation with Integrity FT-IR Reliable Air Monitoring Atmosfir Optics Ltd. and Bruker Optics have come together to provide

More information

Emission Testing August 2013 EPA 4 Benzene Combustor Inlet/Outlet Testing

Emission Testing August 2013 EPA 4 Benzene Combustor Inlet/Outlet Testing Page: 1 of 12 Gate 38B, 45 Friendship Rd Port Botany NSW 2036 Dear Mr G Millard, August 2013 EPA 4 Benzene Combustor Inlet/Outlet Testing Tests were performed 10th August 2013 to determine emissions from

More information

HAZ-SCANNER. Model HIM Complete Air Monitoring Station

HAZ-SCANNER. Model HIM Complete Air Monitoring Station HAZ-SCANNER TM Model HIM-6000 Complete Air Monitoring Station Build Your Own a HAZ-SCANNER HIM-6000 to fit your applications. Use the convenient pre-checklist below! Start with: HIM-6000 EPA Criteria Air

More information

Solutions. Integrated Analyzer Systems & Services. Your Global Partner For Customized Analytical Solutions

Solutions. Integrated Analyzer Systems & Services. Your Global Partner For Customized Analytical Solutions Solutions Integrated Analyzer Systems & Services Your Global Partner For Customized Analytical Solutions BU 10A02A01-01E-A www.yokogawa.com/us/ia/analytical/measurementation/home.htm Core Expertise Measurementation

More information

Meet Ja, H2S, and BTU flare regulations while reducing your total cost of ownership

Meet Ja, H2S, and BTU flare regulations while reducing your total cost of ownership Process Analytics Meet Ja, H2S, and BTU flare regulations while reducing your total cost of ownership As environmental regulations for flare emissions become more stringent, companies are facing immense

More information

Lab Design or Renovation Plans Interview/ Review

Lab Design or Renovation Plans Interview/ Review Lab Design or Renovation Plans Interview/ Review This form is used to notify departments that assist with the lab design or renovation of certain aspects of your research to ensure that proper equipment

More information

Application Note. Hydrogen Purity Analysis by FTIR PROBLEM BACKGROUND

Application Note. Hydrogen Purity Analysis by FTIR PROBLEM BACKGROUND Hydrogen Purity Analysis by FTIR PROBLEM Historically, hydrogen has been employed in a variety of industrial chemical processes. Typically, the purity requirements for this hydrogen have tolerated contaminant

More information

Aeromon. RPAS-assisted detecting and monitoring of gaseous compounds. Airborne Emission Monitoring UAV Arctic, Kuopio

Aeromon. RPAS-assisted detecting and monitoring of gaseous compounds. Airborne Emission Monitoring UAV Arctic, Kuopio Airborne Emission Monitoring RPAS-assisted detecting and monitoring of gaseous compounds 1.11.2016 UAV Arctic, Kuopio Table of contents Who am I? What is? In general - How to measure gases with drones

More information

Measurement & Analytics Measurement made easy. HP30 on-line process hydrogen analyzer Refinery hydrogen optimization

Measurement & Analytics Measurement made easy. HP30 on-line process hydrogen analyzer Refinery hydrogen optimization Measurement & Analytics Measurement made easy HP30 on-line process hydrogen analyzer Refinery hydrogen optimization A robust hydrogen analyzer package for refinery and petrochemical plants The HP30 process

More information

HD and HDL Two-Stage Non-Lube Gas Compressors

HD and HDL Two-Stage Non-Lube Gas Compressors COMPRESSORS CB-325 2009/08 HD and HDL Two-Stage Non-Lube Gas Compressors Air Allene Ammonia Argon Benzene Bromotrifluormethane Butadiene Butane Carbon Dioxide Carbon Monoxide Carbon Tetrachloride Carbon

More information

I n d u P r o AB. Measuring range (ppm) Detector tube name. Gas or vapour to be measured. Tube Code No.

I n d u P r o AB. Measuring range (ppm) Detector tube name. Gas or vapour to be measured. Tube Code No. Detector tube name Tube Code No. Gas or vapour to be measured Measuring range (ppm) No. Of Pump Strokes Shelf Life (year) Note TLV TWA, C (ACGIH) (ppm) Acetaldehyde SAT 4M Acetaldehyde 0 300 C5 Acetic

More information

Chemistry of Petrochemical Processes

Chemistry of Petrochemical Processes Chemistry of Petrochemical Processes ChE 464 Instructor: Dr. Ahmed Arafat, PhD Office: building 45 room 106 E-mail: akhamis@kau.edu.sa www.kau.edu.sa.akhamis files Book Chemistry of Petrochemical Processes

More information

Turnkey configurations for gas chromatographic analysis, including instrumentation, methods, supplies and service. Analysis of Natural Gas

Turnkey configurations for gas chromatographic analysis, including instrumentation, methods, supplies and service. Analysis of Natural Gas Turnkey configurations for gas chromatographic analysis, including instrumentation, methods, supplies and service. Analysis of Natural Gas Agilent Technologies analyzers for the hydrocarbon processing

More information

Bioproducts as Early-Stage Technology Opportunities for Industry and Investors. Peter L Keeling Iowa State University

Bioproducts as Early-Stage Technology Opportunities for Industry and Investors. Peter L Keeling Iowa State University Bioproducts as Early-Stage Technology Opportunities for Industry and Investors Peter L Keeling Iowa State University NSF Engineering Research Center CBiRC Biomass Feedstock Biobased Chemicals Members -

More information

3M Dyneon Fluoropolymers. Product Information. Dyneon solutions. for the Chemical Processing Industry

3M Dyneon Fluoropolymers. Product Information. Dyneon solutions. for the Chemical Processing Industry Fluoropolymers Product Information Dyneon solutions for the Chemical Processing Industry Fluoroplastics Chemical Resistance (Aging Duration of 1000 Hours) Chemicals Concen. % Temp. C PTFE & TFM Modified

More information

OREGON Environmental Laboratory Accreditation Program ORELAP Fields of Accreditation

OREGON Environmental Laboratory Accreditation Program ORELAP Fields of Accreditation MATRIX Reference Code Analyte Code Description STAT Analysis Corporation 40 CFR Part 50 Appendix J Environmental Laboratory Program 3950 Particulates

More information

CEM500-L. Online Gas Analyser. Specialist Of UV Spectroscopy

CEM500-L. Online Gas Analyser. Specialist Of UV Spectroscopy CEM500-L Online Gas Analyser Specialist Of UV Spectroscopy Crédits photos : Tethys Instruments Couverture : Kodda / agence 123rf Page intérieur : Bagiuiani / agence 123rf > CEM500-L Online Gas Analyser

More information

Multi-component gas analysis with speed, repeatability, and reliability.

Multi-component gas analysis with speed, repeatability, and reliability. Multi-component gas analysis with speed, repeatability, and reliability. Rosemount Quantum Cascade Laser Analyzers Achieve unmatched gas analysis performance and realize cost savings with the most advanced

More information

Alberta Ambient Air Quality Objectives and Guidelines Summary Issued February 2013

Alberta Ambient Air Quality Objectives and Guidelines Summary Issued February 2013 Alberta Ambient Air Quality Objectives and Guidelines Summary Issued February 2013 The Alberta Environmental Protection and Enhancement Act (EPEA) allows Alberta Environment to develop ambient air quality

More information

EXM500. Online Gas Analyser. Specialist Of UV Spectroscopy

EXM500. Online Gas Analyser. Specialist Of UV Spectroscopy EXM500 Online Gas Analyser Specialist Of UV Spectroscopy Crédits photos : Tethys Instruments Couverture : Kodda / agence 123rf Page intérieur : Bagiuiani / agence 123rf > EXM500 Online Gas Analyser The

More information

GTC Technology Day. 16 April Hotel Le Meridien New Delhi. Pyrolysis Gasoline Value Upgrades Styrene

GTC Technology Day. 16 April Hotel Le Meridien New Delhi. Pyrolysis Gasoline Value Upgrades Styrene 16 April Hotel Le Meridien New Delhi Pyrolysis Gasoline Value Upgrades Styrene Naphtha Cracker Byproducts Pygas GTC-offered Overall Processing Scheme Raw Pyrolysis Gasoline C 5 Fraction Pygas Hydrotreating

More information