INDOOR AIR QUALITY AND THE ADEQUACY OF CLEANING IN 25 FINNISH SCHOOLS

Size: px
Start display at page:

Download "INDOOR AIR QUALITY AND THE ADEQUACY OF CLEANING IN 25 FINNISH SCHOOLS"

Transcription

1 INDOOR AIR QUALITY AND THE ADEQUACY OF CLEANING IN 25 FINNISH SCHOOLS T Pasanen 1*, T Keskikuru 1, J Ridell 2 and P Pasanen 1 1 Department of Environmental Science, University of Kuopio, Finland 2 Jyväskylä Environment Office, Finland ABSTRACT Indoor air quality and the adequacy of cleaning were studied in 25 schools in a Finnish city. Methods included a questionnaire for teachers (Örebro MM-40-FIN) and measurements of ventilation rate, CO 2, temperature, particulate matter (PM) and surface dust in 56 classrooms. In most classrooms, ventilation rates did not fulfill the rate required by the Finnish building code. CO 2 -concentrations were lowest in classrooms with mechanical ventilation and highest in classrooms with natural ventilation. Ventilation rates correlated with PM in all particle size groups except the smallest one. Total PM-levels exceeded the recommended values, and almost all classrooms were too warm. No correlation was found between PM and surface dust. According to the questionnaire (n=424 teachers), main problems in the working environment were dust, stuffy or dry air and noise. There was a statistically significant correlation between perceived indoor air quality and symptoms. The prevalence of symptoms did not explain dissatisfaction with work. INDEX TERMS Dust, Schools, Perceived air quality, Ventilation rate, Cleaning quality INTRODUCTION The prevalence of indoor air problems, including moisture and mold problems, found in Finnish schools has increased in recent years. According to recent studies, the most common problems are draft in the winter, insufficient ventilation, and visible mold or the smell of mold. The consequences of low ventilation rates include elevated levels of carbon dioxide (CO 2 ) and other air contaminants in classrooms. Poor indoor air causes various symptoms, such as fatigue, headache, stuffy nose, and eye and skin problems. Efficient ventilation and adequate cleaning can reduce the level of contaminants. It is important to check the ventilation system regularly and to repair it when needed. If the ventilation system is not adjusted properly and it is not used correctly, actual ventilation rates can be significantly lower than the intended rates. As group sizes in classrooms have been increasing, the number of students in classrooms may be higher than what the ventilation system is designed for. The purpose of this study was to determine the indoor air quality and adequacy of cleaning in schools. This survey was needed because previous studies have indicated that the indoor air quality in schools is often poor. Over the past years, resources for school cleaning have been reduced, which has raised concerns about the effects of diminished cleaning on indoor air quality. The methods included a questionnaire for teachers and measurements of ventilation rate, CO 2, particulate matter (PM), amount of surface dust, and temperature in the classrooms. * Contact author tjpasane@ .unc.edu 87

2 The relationship between teachers symptoms, perceived air quality and measured factors was analyzed statistically. METHODS All schools that were located within the city boundaries were included in the study. Out of the 25 schools, 17 were elementary schools, six were junior high schools and three were high schools. Depending on the size of the school, one-to-three classrooms were randomly chosen for measurements. The measurements were done in typical classrooms, not in special classrooms, for example those used for teaching arts or sports. Sixteen schools were ventilated with mechanical supply and exhaust, seven were ventilated with mechanical exhaust and three had natural ventilation. The following factors were measured in the classrooms: ventilation rate, CO 2, PM, amount of surface dust, room temperature, temperature of supply air, and relative humidity (RH). Ventilation rates were measured according to the European Standard (EN 12599, 2000). CO 2, room temperature and RH were measured with a manual measuring instrument about 5-10 minutes before breaks. PM was measured at the same time with a laser particle counter (Climet Instruments CI-500), and the results were converted to mass concentration. The amount of surface dust was measured with an optical instrument (BM-Dustdetector), which is based on the transmission of a laser beam through a sampling tape. The proceedings of the measurements have been presented in more detail previously (Pasanen, 2001). Measurements were carried out in February-March 2001 except for ventilation rates, which were measured in March-April Perceived air quality and teachers symptoms during the past three months were investigated with a questionnaire (Örebro MM-40-FIN). The questionnaire was delivered in January The relationship between teachers symptoms, perceived air quality and measured indoor air factors was analyzed statistically. The objective was to find out the relationship between teachers symptoms and the perceived air quality. In addition, the relationship between symptoms and confounding factors, such as gender, age, length of employment, smoking, and dissatisfaction with work was also investigated. Finally, the relationship between different indoor air factors was studied. To study the prevalence of symptoms, they were categorized in the same way as in the Örebro-questionnaire. The first category included general symptoms, such as fatigue, headache, dizziness and difficulties concentrating, the second category included irritation symptoms related to the eyes and the upper respiratory tract, and the third category included skin symptoms. Teachers responses about the prevalence of symptoms were coded by giving the answer never, 0 points, yes, sometimes, 1 point and yes, every week, 2 points. Overall scores for each symptom group and for all symptoms together were calculated from these results. The normality of the overall scores was tested with Kolmogorov-Smirnov-test. The responses about perceived air quality were managed the same way. The difference between the overall scores of the symptom categories for 2-classed factors was tested with Mann-Whitney-test. Examples of 2-classed factors include gender, smoking status, and satisfaction with work. When the factors had more than two classes Kruskal- Wallis-test was used. The effect of different confounding factors on satisfaction with work, such as existing allergy, gender, age, smoking, length of employment, and the overall scores of symptoms, was tested using logistic regression. 88

3 The relationship between measured factors as well as the relationship between symptoms and perceived air quality was investigated by determining their correlation coefficient (Pearson s and Spearman s correlation coefficients). For example, the correlation between PM in different particle sizes and the amount of surface dust on different surface types was investigated. The relationship between ventilation rate and temperature, CO 2 -level, PM 10 and total PM was studied. In addition, the relationship between room temperature and the temperature of supply air was determined. RESULTS AND DISCUSSION Ventilation rates and CO 2 -concentration Almost without exception the ventilation rates failed to fulfill the rate of fresh air required by the Finnish building code (D2, 1987) for classrooms. The mean ventilation rate in the classrooms ventilated with mechanical exhaust was 1.4 l/s, person or 0.5 l/s, m 2 and the required rate (6 l/s, person) was not fulfilled in any of these classrooms. In classrooms ventilated with mechanical exhaust and supply the ventilation rates were higher, the mean ventilation rate being 3.3 l/s, person or 1.3 l/s, m 2. Low ventilations rates resulted in high CO 2 -concentrations. In classrooms ventilated with mechanical exhaust and supply the CO 2 - concentrations (mean 1190 ppm, n=40) were clearly lower than in classrooms that were ventilated with natural ventilation (mean 2020 ppm, n=4) or mechanical exhaust only (mean 1850 ppm, n=12). The limit concentration value of 1500 ppm for indoor air (Finnish building code) was exceeded only in 10% of classrooms ventilated with mechanical exhaust and supply, whereas the limit value was exceeded in two thirds of classrooms ventilated with mechanical exhaust. There was a strong negative correlation between CO 2 -levels and ventilation rates (r=-0.759, p=0.000). Temperature and relative humidity Almost all classrooms were too warm (mean 23,3 ºC) in relation to comfortable room temperature. Only in 10 classrooms the temperature was within the limits of S2-class for winter (20-22 ºC) of the Classification of Indoor Climate (Classification of Indoor Climate 2000). In statistical analysis no significant correlation between room temperature and ventilation rate was found. Relative humidity in the classrooms was low (mean 23.1 %), which is typical during heating season. Relative humidity was lowest in classrooms ventilated with mechanical exhaust and supply (mean 20.4 %), which resulted from higher ventilation rates in these classrooms. The mean temperature of supply air was 20.3 ºC ( ºC). There are no requirements for the temperature of supply air, but supply air should not cause a draft or increase the temperature burden in the room. In many classrooms where room temperature was too high, the temperature of supply air was high as well. However, a statistically significant correlation between room temperature and the temperature of supply air was not found. Particulate matter and the amount of surface dust In classrooms ventilated with mechanical exhaust and supply, PM 10 was lower (mean 120 µg/m 3 ) than in classrooms ventilated with mechanical exhaust (mean 210 µg/m 3 ) or natural ventilation (mean 280 µg/m 3 ). The highest concentrations were measured in elementary schools or in classrooms where students moved around often during class hours. Respectively, the lowest results were obtained in junior high and high schools, where students 89

4 stayed most of the time at their desks. Except for a few cases, PM 10 did not vary significantly within schools. Statistical analysis showed no correlation for ventilation rate and the smallest particle fraction ( µm). This was expected because fine particles do not settle on surfaces but instead drift in the air. Significant negative correlation was found between ventilation rates (l/s, person) and all other fractions of PM. There was a clear negative correlation between ventilation rates and PM 10 (r=-0.447, p=0.001) as well as ventilation rates and total PM (r= , p=0.002). However, none of the fractions of PM correlated with the amount of dust on different surface types. The amount of surface dust was measured on three kinds of surfaces: on floors, on easily accessible surfaces (surfaces between floor and 180 cm) and hard-to-access surfaces (higher than 180 cm). The present results show that the floors of the schools were very clean. Except for three schools, all schools were in class 5, the cleanest class (less than 2.5 % of dust when measured with BM-Dusdetector) of INSTA 800 cleanliness classification (Nilsen et al., 2000). The remaining three schools were in class 4 (less than 5.0 % of dust). This was expected since the floors of the schools are wiped daily. The easily accessible surfaces varied more in their dust content than the floors. Eight schools were in class 5 (< 1.0 % of dust), three schools were in class 4 (<1.5 % of dust), five schools were in class 3 (<2.5 % of dust), seven schools in class 2 (<5.0 % of dust) and one school was in class 1 (>5.0 % of dust). The amount of dust on easily accessible surfaces varied considerably within the same school. Even though the floors of the schools are cleaned daily, easily accessible surfaces may have been cleaned on different days. Usually they are cleaned once a week, or when the surfaces seem dusty. High surfaces, such as the tops of cupboards are usually cleaned only once a year. This is seen in the results: most of the schools (76%) were in class 1 (>8 % of dust). In many classrooms these surfaces were covered by a thick, visible layer of dust. The effect of dust settled on high, hard-to-access surfaces on indoor air quality has not been studied sufficiently. The amount of dust on hard-to-access surfaces did not correlate with the amount of dust on floors or on easily accessible surfaces, but there was a weak correlation between the amount of dust on floors and on easily accessible surfaces (r=0.312, p=0.024). The amount of surface dust on any type of surface did not correlate with PM in any size range. The surface dust results produced with the reliable optical method are of special interest because they reveal severe problems in the quality of school cleaning. Symptoms According to the questionnaire (n=424, reply percentage 69%), most significant problems in the working environment were dust and dirt, stuffy or dry air and noise. Most common symptoms related to working environment were irritation of nose, hoarseness and dryness of throat, skin symptoms on hands and fatigue. In elementary schools and junior high schools, more than 20% of teachers reported these symptoms. Women had more symptoms than men in all symptom categories except irritation symptoms. Other background factors, such as age, length of employment, or smoking did not correlate significantly with the prevalence of symptoms. Dissatisfaction with work did not correlate with the prevalence of symptoms either. However, the difference between men and women still existed (i.e., among teachers who were dissatisfied with their work, women had more symptoms than men). Symptoms correlated moderately with perceived air quality. When using logistic regression to find the reasons for teachers being dissatisfied with work, the main factors turned out to be previous 90

5 or current asthma and the length of employment, although their overall significance was small. The prevalence of symptoms did not explain dissatisfaction with work. These findings indicate that other reasons, such as psychological factors, affect work dissatisfaction even more than environmental factors. Most of the teachers chose insufficient ventilation and/or crowded classrooms as the reasons for poor air quality. Many teachers commented that air quality depends on the number of students in the classroom and the time of the day, so that the air quality is worst in the afternoons. Teachers also mentioned that when the air quality is poor, children are more restless and tired. When asked about what should be done to improve air quality, most teachers chose increasing the ventilation, improving cleaning and adjusting the heating system. The symptoms of building users and perceived air quality have previously been studied in various working environments, but an extensive study has not been made in schools in Finland. It should be noticed that the participants of the questionnaire were teachers, and children can be more sensitive and thus more susceptible to adverse health effects. CONCLUSIONS The results of this study show that improvements in many areas of indoor climate of the schools are urgently needed. Ventilation rates and room temperatures were not adjusted according to the number of people in the room. The observed high PM-levels can be decreased by improving ventilation, cleaning the classrooms efficiently, and reducing dust sources indoors. Efficiency of cleaning, especially in areas that are typically cleaned only rarely, and the effect of excessive dust on these surfaces on indoor air quality should be assessed. This study revealed new information about teachers symptoms and the perceived air quality, as well as the relationships between different indoor air factors. In this study, there was a statistically significant correlation between symptoms and perceived air quality. ACKNOWLEGEMENTS The authors would like to thank all the people in the City of Jyväskylä who contributed to this project. We would like to thank especially the teachers and the students for their patience when the measurements were carried out. REFERENCES Classification of Indoor Climate Target Values, Design Guidance and Product Requirements. FiSIAQ publication 5 E. Espoo, Finland D2, Finnish building code for indoor air and ventilation requirements. Ministry of Environment. EN 12599, European standard. Ventilation for Buildings Test procedures and measuring methods for handing over installed ventilation and air conditioning systems. March Nilsen SK, Schjønning AL, Dahl I, et al INSTA 800. New internordic standard for measuring cleaning quality. Proceedings of Buildings 2000, Vol 4, Pasanen, T, 2000 [text in Finnish]. Sisäilman laatu ja pintapölyn määrä Jyväskylän kouluissa. Kuopion yliopiston ympäristötieteiden monistesarja 8/

THE EFFECT OF DUCT CLEANING ON INDOOR AIR QUALITY IN OFFICE BUILDINGS

THE EFFECT OF DUCT CLEANING ON INDOOR AIR QUALITY IN OFFICE BUILDINGS THE EFFECT OF DUCT CLEANING ON INDOOR AIR QUALITY IN OFFICE BUILDINGS S Kolari 1*, M Luoma 1, M Ikäheimo 2 and P Pasanen 2 1 VTT Technical Research Centre of Finland, Espoo, Finland 2 University of Kuopio,

More information

Indoor Air Quality Program

Indoor Air Quality Program Indoor Air Quality Program Table of Contents I. Program Goals and Objectives... 2 II. Scope and Application... 2 III. Definitions... 2 IV. Responsibilities... 2 V. Reporting Procedures... 3 VI. Investigation

More information

Classification of Indoor Climate, Construction, and Finishing Materials

Classification of Indoor Climate, Construction, and Finishing Materials Classification of Indoor Climate, Construction, and Finishing Materials 0. Seppiinen Department of Mechanical Engineering, Helsinki University of Technology, Espoo, Finland Abstract Good indoor climate

More information

1204 North Road (Rt. 117) Groton, Connecticut 06340

1204 North Road (Rt. 117) Groton, Connecticut 06340 FTP Construction A nil 2014 Communications (24 hours): website: www.mysticair.com e-mail: maqc2 @ aol.com Office: (860) 449-8903 FAX: (860) 449-8860 Toll Free: 1 (800) 247-7746 monoxide, carbon dioxide,

More information

Indoor Air Quality Assessments

Indoor Air Quality Assessments HS13_IAQ_SOP 1. Purpose and Requirements Symptoms arising from poor indoor air quality often mimic those symptoms commonly associated with a cold, flu or allergies. These symptoms may include upper respiratory

More information

INDOOR AIR QUALITY ASSESSMENT

INDOOR AIR QUALITY ASSESSMENT INDOOR AIR QUALITY ASSESSMENT Biddeford Intermediate School Biddeford Primary School JFK Memorial Kindergarten Center Biddeford High School Air Quality Management Services, Inc. PREPARED FOR Biddeford

More information

AN INTERVENTION STUDY OF THE RELATIONSHIPS BETWEEN INDOOR AIR-RELATED HEALTH PROBLEMS, PRODUCTIVITY AND CLEANLINESS IN AN OFFICE SETTING.

AN INTERVENTION STUDY OF THE RELATIONSHIPS BETWEEN INDOOR AIR-RELATED HEALTH PROBLEMS, PRODUCTIVITY AND CLEANLINESS IN AN OFFICE SETTING. AN INTERVENTION STUDY OF THE RELATIONSHIPS BETWEEN INDOOR AIR-RELATED HEALTH PROBLEMS, PRODUCTIVITY AND CLEANLINESS IN AN OFFICE SETTING. SK Nilsen* 1, P Blom 2, J Rydock 2, J Nersveen 2 and KI Fostervold

More information

CLEANLINESS REQUIREMENTS FOR VENTILATION DUCTS IN THE NEW FINNISH LABELING SYSTEM: PRACTICAL CONSEQUENCES

CLEANLINESS REQUIREMENTS FOR VENTILATION DUCTS IN THE NEW FINNISH LABELING SYSTEM: PRACTICAL CONSEQUENCES 1 CLEANLINESS REQUIREMENTS FOR VENTILATION DUCTS IN THE NEW FINNISH LABELING SYSTEM: PRACTICAL CONSEQUENCES P. Pasanen (PhD), R. Holopainen, V. Asikainen, M. Björkroth, M. Tuomainen, J. Säteri, O. Seppänen,

More information

Indoor Air Quality Improvement in a School Building in Delhi

Indoor Air Quality Improvement in a School Building in Delhi Indoor Air Quality Improvement in a School Building in Delhi Maija Virta #1, Suhaas Mathur #1 # Santrupti engineers Private Limited 1083, 35 th D Cross, 4 th T Block, Jayanagar, Bangalore 560041, India

More information

University of Rochester Environmental Health & Safety Indoor Air Quality Program March 23, 2005

University of Rochester Environmental Health & Safety Indoor Air Quality Program March 23, 2005 University of Rochester Environmental Health & Safety Indoor Air Quality Program March 23, 2005 1. Purpose: The purpose of this program is to inform the University community about indoor air quality (IAQ).

More information

Goals. Data MM- questionnaires. ELIB study (domestic buildings) MM Questionnaire. HOME ENVIRONMENT (often bothered) %

Goals. Data MM- questionnaires. ELIB study (domestic buildings) MM Questionnaire. HOME ENVIRONMENT (often bothered) % Goals The research program ELIB studied the technical characteristics, energy use and indoor climate of the Swedish building stock 1991-1992. Technical characteristics of the building stock, regarding

More information

According to our research and study most occupant complaints relating to IAQ are attributable to the following factors:

According to our research and study most occupant complaints relating to IAQ are attributable to the following factors: Report pertaining to the Duct Cleaning of ICU! &ICU2 at Hospital 5 th & 6 th Floor. The IAQ Report documents by Photograph (at random) photo shots of the various ducting systems & AHU Systems for work

More information

Department of Environmental and Occupational Health, Faculty of Medicine and Health Sciences, Universiti Putra Malaysia, Selangor, Malaysia.

Department of Environmental and Occupational Health, Faculty of Medicine and Health Sciences, Universiti Putra Malaysia, Selangor, Malaysia. ORIGINAL ARTICLE RETROFITTING AND PURPOSED-BUILT BUILDINGS: INDOOR AIR QUALITY AND SICK BUILDING SYNDROME AMONG PRIVATE HIGHER LEARNING INSTITUTION STUDENTS IN KUALA LUMPUR AND SELANGOR Nor Faeiza M, Juliana

More information

SICK BUILDING SYNDROME SYMPTOMS AND PERFORMANCE IN A FIELD LABORATORY STUDY AT DIFFERENT LEVELS OF TEMPERATURE AND HUMIDITY

SICK BUILDING SYNDROME SYMPTOMS AND PERFORMANCE IN A FIELD LABORATORY STUDY AT DIFFERENT LEVELS OF TEMPERATURE AND HUMIDITY SICK BUILDING SYNDROME SYMPTOMS AND PERFORMANCE IN A FIELD LABORATORY STUDY AT DIFFERENT LEVELS OF TEMPERATURE AND HUMIDITY L Fang, DP Wyon, G Clausen and PO Fanger International Centre for Indoor Environment

More information

VOLUSIA COUNTY HEALTH DEPARTMENT BUILDING DISASTER ASSESSMENT REPORT Pg 1 of 5

VOLUSIA COUNTY HEALTH DEPARTMENT BUILDING DISASTER ASSESSMENT REPORT Pg 1 of 5 VOLUSIA COUNTY HEALTH DEPARTMENT BUILDING DISASTER ASSESSMENT REPORT Pg 1 of 5 Inspection ID Building or Room Name Address Building Contact Name and Phone Number Investigator(s) Date Started Date Closed

More information

Fire insulations of ventilation equipment and shafts as a source of man-made mineral fibres

Fire insulations of ventilation equipment and shafts as a source of man-made mineral fibres Fire insulations of ventilation equipment and shafts as a source of man-made mineral fibres Eija Puhakka, Jukka Kärkkäinen, Eija Pesonen-Leinonen and Jarkko Lesonen Finnish Indoor Air Measurement Service

More information

When Building a New Home

When Building a New Home When Building a New Home Building a new home provides the opportunity for preventing indoor air problems. However, it can result in exposure to higher levels of indoor air contaminants if careful attention

More information

Air heating of passive house office buildings in cold climates how high supply temperature is acceptable?

Air heating of passive house office buildings in cold climates how high supply temperature is acceptable? Air heating of passive house office buildings in cold climates how high supply temperature is acceptable? Axel Cablé *1, Mads Mysen 1,2, Hugo Lewi Hammer 2 and Kari Thunshelle 1 1 SINTEF Forskningsveien

More information

Indoor Air Quality Assessment Report

Indoor Air Quality Assessment Report Indoor Air Quality Assessment Report For M&W Business Centre At Unit B, 19/F, Kyoto Plaza, 491-499 Lockhart Road, Causeway Bay, Hong Kong Tel: 3896 0399 Attn: Melody Ko Tested and prepared by: Carman Lam

More information

Indoor Air Quality. Basic Management for Healthy Office Environments. Peter A Shelling CSP CIEC

Indoor Air Quality. Basic Management for Healthy Office Environments. Peter A Shelling CSP CIEC Indoor Air Quality Basic Management for Healthy Office Environments Peter A Shelling CSP CIEC Why is Indoor Air Quality (IAQ) a problem now? People spend more time indoors than ever before (90% for most

More information

Humidification and perceived indoor air quality in

Humidification and perceived indoor air quality in 322 Environmental Epidemiology Unit, Department of Public Health, University of Helsinki, Finland L M Reinikainen J J K Jaakkola Technical Reseach Centre of Finland L Aunela-Tapola Laboratory of Heating,

More information

Comfortable and Healthy Indoor Climate EEN-E4001

Comfortable and Healthy Indoor Climate EEN-E4001 Comfortable and Healthy Indoor Climate EEN-E4001 Lecture 3: Indoor Air Quality Risto Kosonen Aalto University, Espoo, Finland Presentation outline Factors affecting indoor air quality Indoor air pollutants

More information

Indoor Air Quality Backgrounder: The Basics

Indoor Air Quality Backgrounder: The Basics Indoor Quality Backgrounder: The Basics I ndoor air quality (IAQ) is an increasingly important issue in schools across the nation. IAQ can directly affect the health and comfort of students and staff.

More information

HHHY Air Quality Test. Name: Joe & Mary Sample Test-in Date: 4/6/2017 Address: 1234 N. Somewhere St. Report Date: 4/6/2017 Tucson, Az 85712

HHHY Air Quality Test. Name: Joe & Mary Sample Test-in Date: 4/6/2017 Address: 1234 N. Somewhere St. Report Date: 4/6/2017 Tucson, Az 85712 Name: Joe & Mary Sample Date: 4/6/2017 Address: 1234 N. Somewhere St. Report Date: 4/6/2017 *1= Acceptable *2= Greater Than but less than Double Outdoor *3= Unacceptable Thank you for the opportunity to

More information

Indoor Air Quality Program

Indoor Air Quality Program Environmental Health and Safety Office Indoor Air Quality Program The purpose of this program is to inform the University community about indoor air quality (IAQ). Adopted: May 28, 2008 Revised: April

More information

Use of local convective and radiant cooling at warm environment

Use of local convective and radiant cooling at warm environment Downloaded from orbit.dtu.dk on: Nov 01, 2018 Use of local convective and radiant cooling at warm environment Melikov, Arsen Krikor; Krejcirikova, Barbora; Kaczmarczyk, Jan; Duszyk, Marcin; Sakoi, Tomonori

More information

Published in: 7th NCEUB Conference : The changing context of comfort in an unpredictable world, April 2012

Published in: 7th NCEUB Conference : The changing context of comfort in an unpredictable world, April 2012 Impact of available and perceived control on comfort and health in European office buildings Boerstra, A.C.; Beuker, T.C.; Loomans, M.G.L.C.; Hensen, J.L.M. Published in: th NCEUB Conference : The changing

More information

Visible emissions were not observed in the school in the vicinity of the construction containment.

Visible emissions were not observed in the school in the vicinity of the construction containment. June 22, 2018 To: Waverly Elementary School From: Christopher Madden, CIH Indoor Environmental Quality Manager Re: Indoor Air Quality Testing During Renovations - May As Waverly Elementary School is currently

More information

"INDOOR AIR QUALITY"

INDOOR AIR QUALITY PRESENTER'S GUIDE "INDOOR AIR QUALITY" Education to Help Identify, Correct and Prevent Indoor Air Quality Problems Quality Safety and Health Products, for Today...and Tomorrow OUTLINE OF MAJOR PROGRAM

More information

Green Schools Track Ensuring Proper Installation and Commissioning of HVAC Systems for Energy Efficiency and Indoor Air Quality

Green Schools Track Ensuring Proper Installation and Commissioning of HVAC Systems for Energy Efficiency and Indoor Air Quality Green Schools Track Ensuring Proper Installation and Commissioning of HVAC Systems for Energy Efficiency and Indoor Air Quality April 10, 2018 Agenda The Importance of Ventilation in Classrooms Ensuring

More information

PM1 FINE DUST HAZARD TO HEALTH APAC

PM1 FINE DUST HAZARD TO HEALTH APAC PM1 FINE DUST HAZARD TO HEALTH APAC Clean air solutions FOCUS ON PM1 EXAMPLE OF PARTICLES SIZES FOR PROTECTION OF HUMAN HEALTH Hair: ~70 µm Pollen: ~10-100 µm We all know that air pollution is bad for

More information

April 21, Dear Mike,

April 21, Dear Mike, AECOM 1555 North RiverCenter Drive Suite 214 Milwaukee, Wisconsin 53212 414.944.6080 tel 414.944.6081 fax April 21, 2015 Mr. Michael Lewis, P.E. City of West Allis Department of Public Works/City Engineer

More information

Visible emissions were not observed in the school in the vicinity of the construction containment.

Visible emissions were not observed in the school in the vicinity of the construction containment. April 23, 2018 To: Waverly Elementary School From: Christopher Madden, CIH Indoor Environmental Quality Manager Re: Indoor Air Quality Testing During Renovations - March As Waverly Elementary School is

More information

What s in the Air - Truths, Myths & Simple Strategies

What s in the Air - Truths, Myths & Simple Strategies What s in the Air - Truths, Myths & Simple Strategies Presented By: Marek Plawinski, M.Sc., MPH, R.Kin. About Inc. Workshop Objectives 1. What is indoor Air Quality 2. IAQ Investigation 3. Simple Field

More information

Living and working in a busy metropolis like Hong Kong, we normally spend 80% to 90%

Living and working in a busy metropolis like Hong Kong, we normally spend 80% to 90% = =Introduction!"#$%&'()*+,-.UMBJVMB!"#$%&'($% )*!"#$%&'()*+,-./01234)5678!94:/0;

More information

VENTILATION RATES AND IAQ IN EUROPEAN STANDARDS AND NATIONAL REGULATIONS

VENTILATION RATES AND IAQ IN EUROPEAN STANDARDS AND NATIONAL REGULATIONS VENTILATION RATES AND IAQ IN EUPEAN STANDARDS AND NATIONAL REGULATIONS Nejc Brelih *1, Olli Seppänen 1 1 REHVA Federation of European heating, ventilation and air conditioning associations Rue Washington,

More information

Prepared by: LBS HSE Approved by: Geoff Atkins Issue Date: New Policy

Prepared by: LBS HSE Approved by: Geoff Atkins Issue Date: New Policy The University of British Columbia Land and Building Services MOULD PROCEDURE Work Procedure I-B-46 Prepared by: LBS HSE Approved by: Geoff Atkins Issue Date: New Policy Replaces: 1.0 APPLICATION Moulds

More information

Notes on Indoor Air Quality

Notes on Indoor Air Quality Notes on Indoor Air Quality Indoor Air Quality (IAQ) a Health and Safety Concern? Indoor air quality has become an important occupational health and safety concern. Energy conservation measures instituted

More information

HAZARD EVALUATION AND TECHNICAL ASSISTANCE REPORT HETA SOCIAL SECURITY ADMINISTRATION SAN JUAN, PUERTO RICO AUGUST 1991

HAZARD EVALUATION AND TECHNICAL ASSISTANCE REPORT HETA SOCIAL SECURITY ADMINISTRATION SAN JUAN, PUERTO RICO AUGUST 1991 This Health Hazard Evaluation (HHE) report and any recommendations made herein are for the specific facility evaluated and may not be universally applicable. Any recommendations made are not to to be considered

More information

The Design of Building and Services Affects Indoor Environments and Impacts Productivity

The Design of Building and Services Affects Indoor Environments and Impacts Productivity The Design of Building and Services Affects Indoor Environments and Impacts Productivity Bohgard, Mats 2012 Link to publication Citation for published version (APA): Bohgard, M. (2012). The Design of Building

More information

Sumit Sharma, Ved Prakash Sharma, R Suresh TERI GRIHA SUMMIT 2016

Sumit Sharma, Ved Prakash Sharma, R Suresh TERI GRIHA SUMMIT 2016 Sumit Sharma, Ved Prakash Sharma, R Suresh TERI GRIHA SUMMIT 2016 Goal SDG Linkage Goal 1 Goal 2 Goal 3 End poverty in all its forms everywhere End hunger, achieve food security and improved nutrition

More information

Indoor Air Quality Assessments during Renovations at Waverly Elementary School Project #J (January 4, 12, 15, 25 and 29, 2018)

Indoor Air Quality Assessments during Renovations at Waverly Elementary School Project #J (January 4, 12, 15, 25 and 29, 2018) March 29, 2018 Mr. Jeff Klenk Howard County Public School System (HCPSS) 10910 Route 108 Ellicott City, MD 21043 RE: Indoor Air Quality Assessments during Renovations at Waverly Elementary School Project

More information

THE EFFECT OF INTENSIVE VACUUMING ON INDOOR PM MASS CONCENTRATION

THE EFFECT OF INTENSIVE VACUUMING ON INDOOR PM MASS CONCENTRATION THE EFFECT OF INTENSIVE VACUUMING ON INDOOR PM MASS CONCENTRATION K White 1 and P Dingle 1 School of Environmental Science, Murdoch University, Murdoch, WA, Australia ABSTRACT A study was conducted in

More information

The opinion on risk assessment on indoor air quality by SCHER

The opinion on risk assessment on indoor air quality by SCHER Indoor Air 2008, 17-22 August 2008, Copenhagen, Denmark - Paper ID: Tu9K2 The opinion on risk assessment on indoor air quality by SCHER Hannu Komulainen * National Public Health Institute, Department of

More information

Which indoor air pollutants raise concern? How can indoor air quality be determined?

Which indoor air pollutants raise concern? How can indoor air quality be determined? page 1/7 Source document: Indoor Air Quality SCHER (2008) Summary & Details: GreenFacts Context - Air pollution be it indoors or outdoors is a major environmental health concern as it can lead to serious

More information

INDOOR AIR QUALITY ASSESSMENT. Department of Developmental Services & Department of Mental Health Service Center 35 Nagog Park Acton, Massachusetts

INDOOR AIR QUALITY ASSESSMENT. Department of Developmental Services & Department of Mental Health Service Center 35 Nagog Park Acton, Massachusetts INDOOR AIR QUALITY ASSESSMENT Department of Developmental Services & Department of Mental Health Service Center 35 Nagog Park Acton, Massachusetts Prepared by: Massachusetts Department of Public Health

More information

HEALTHY LOW ENERGY REDESIGNS FOR SCHOOLS IN DELHI: INVENTORY OF THE CURRENT CONDITIONS

HEALTHY LOW ENERGY REDESIGNS FOR SCHOOLS IN DELHI: INVENTORY OF THE CURRENT CONDITIONS Vervoort, J. W. P., Boerstra, A. C., Virta, M., Mishra, A. K., Loomans, M. G. L. C., Frijns, A. J. H. & Hensen, J. L. M. 2018. Healthy low energy redesignss for schools in Delhi: inventory of the current

More information

Student Performance and Absenteeism Related to IAQ

Student Performance and Absenteeism Related to IAQ Student Performance and Absenteeism Related to IAQ Balancing IAQ and Energy Conservation/Efficiency Objectives in Schools ASHRAE Summer Meeting Louisville, KY June 21, 2009 by Francis (Bud) J. Offermann

More information

Make way for fresh air, live and work healthier

Make way for fresh air, live and work healthier Make way for fresh air, live and work healthier Make way for fresh air, live and work healthier Building insulation levels are increasing all the time. Good for the energy bill and the comfort at home

More information

Standards for Ventilation, IAQ, and Thermal Comfort EVALUATION OF THE INDOOR ENVIRONMENT THERMAL ENVIRONMENT INDOOR ENVIRONMENT.

Standards for Ventilation, IAQ, and Thermal Comfort EVALUATION OF THE INDOOR ENVIRONMENT THERMAL ENVIRONMENT INDOOR ENVIRONMENT. Standards for Ventilation, IAQ, and Thermal Comfort Bjarne W. Olesen, PhD. Wirsbo-Velta, Germany Adjunct professor, Technical University Denmark Chair ISO/TC159/SC5/WG1 Ergonomics of the thermal environment

More information

GDU - MULTISENS. Datalogger with built in sensors Made for accurate indoor air quality measurements. Key features of the GDU MultiSens

GDU - MULTISENS. Datalogger with built in sensors Made for accurate indoor air quality measurements. Key features of the GDU MultiSens GDU - MULTISENS sensors Made for accurate indoor air quality measurements Key features of the GDU MultiSens Built in sensors for measuring - Temperature & Humidity - CO₂ concentration - Pressure difference

More information

INDOOR AIR QUALITY PROGRAM

INDOOR AIR QUALITY PROGRAM INDOOR AIR QUALITY PROGRAM (Adopted from California State University Office of the Chancellor s Sample IAQ Program) 1 TABLE OF CONTENTS Page 1.0 REGULATORY AUTHORITY.........................................

More information

360-INDOOR AIR QUALITY PROGRAM

360-INDOOR AIR QUALITY PROGRAM 360.1 PURPOSE A. To help ensure employees and students at Central New Mexico Community College (CNM) are provided a workplace free of recognized indoor air quality hazards. 360.2 SCOPE A. CNM recognizes

More information

INDOOR AIR QUALITY MANAGEMENT POLICY

INDOOR AIR QUALITY MANAGEMENT POLICY INDOOR AIR QUALITY MANAGEMENT POLICY I. MISSION STATEMENT The health, comfort, and learning environment of students and staff are important aspects of the Lafayette Parish School System s (LPSS) mission.

More information

increasing the potential for long term and short term health problems for students and staff

increasing the potential for long term and short term health problems for students and staff IAQ Backgrounder Indoor Air Quality T he goal of the Checklist is to provide clear and easily applied activities that you can use to help prevent indoor air quality problems and resolve any problems promptly

More information

Human Response to Ductless Personalized Ventilation with Local Air Cleaning: Air Quality and Prevalence of SBS Symptoms

Human Response to Ductless Personalized Ventilation with Local Air Cleaning: Air Quality and Prevalence of SBS Symptoms Downloaded from orbit.dtu.dk on: Dec 20, 2017 Human Response to Ductless Personalized Ventilation with Local Air Cleaning: Air Quality and Prevalence of SBS Symptoms Dalewski, Mariusz; Bivolarova, Maria

More information

INDOOR AIR QUALITY OF AIR-CONDITIONED FOOD COURTS: PRELIMINARY FINDINGS IN A TROPICAL CITY STATE

INDOOR AIR QUALITY OF AIR-CONDITIONED FOOD COURTS: PRELIMINARY FINDINGS IN A TROPICAL CITY STATE Proceedings: Indoor Air 2 INDOOR AIR QUALITY OF AIR-CONDITIONED FOOD COURTS: PRELIMINARY FINDINGS IN A TROPICAL CITY STATE HM Yap * and PL Ooi 1 1 Department of Quarantine & Epidemiology, Ministry of The

More information

Oregon. 800 NE Oregon St. #640 Portland, OR (971)

Oregon. 800 NE Oregon St. #640 Portland, OR (971) Air Quality Frequently Asked Questions Oregon Environmental Public Health Tracking (EPHT) Oregon ENVIRONMENTAL PUBLIC HEALTH TRACKING 800 NE Oregon St. #640 Portland, OR 97232 www.oregon.gov/dhs/ph/epht

More information

Do European standards for indoor air quality take into account outdoor air quality? Professor Bjarne W. Olesen, PhD, Department of Civil Engineering

Do European standards for indoor air quality take into account outdoor air quality? Professor Bjarne W. Olesen, PhD, Department of Civil Engineering Do European standards for indoor air quality take into account outdoor air quality? Professor Bjarne W. Olesen, PhD, Department of Civil Engineering Technical University of Denmark Global impact on people

More information

IAQ Workshop. Assessing Common IAQ Contaminants and Ventilation Systems. Dru Sahai

IAQ Workshop. Assessing Common IAQ Contaminants and Ventilation Systems. Dru Sahai IAQ Workshop Assessing Common IAQ Contaminants and Ventilation Systems Dru Sahai Public Health Ontario Indoor air quality workshop CIPHI National Meeting Winnipeg, MB June 22, 2013 Outline Introduction

More information

Improving Indoor Air Quality. Presented by Theo Cole, EIT

Improving Indoor Air Quality. Presented by Theo Cole, EIT Improving Indoor Air Quality Presented by Theo Cole, EIT What Is Indoor Air Quality? IAQ refers to the air quality in and around buildings and structures, especially in relation to the health and comfort

More information

Air Quality Monitoring Air Quality Index System and forecasting model in Senegal

Air Quality Monitoring Air Quality Index System and forecasting model in Senegal Ministry of Environment and Sustainable Development Direction of Environment and Classified Establishment Centre for Air Quality Management (CGQA) Regional Consutation on Air Quality, Clean Vehicles and

More information

Measuring Indoor Air Quality presented to AAFAME Members Nov. 14, 2017

Measuring Indoor Air Quality presented to AAFAME Members Nov. 14, 2017 Measuring Indoor Air Quality presented to AAFAME Members Nov. 14, 2017 What is Indoor Air Quality? Appropriate IAQ can be defined as a function of three different components: 1) appropriate thermal comfort,

More information

Air distribution and temperature control in classrooms

Air distribution and temperature control in classrooms Air distribution and temperature control in classrooms Jarek Kurnitski D.Sc., Docent HELSINKI UNIVERSITY OF TECHNOLOGY Laboratory of Heating, Ventilation and Air Conditioning Swegon Air Academy 11.6.2008

More information

2/22/2008. Indoor Environmental (Air) Quality. Time Spent in Locations: Indoors & Outdoors. Why Should You Care About Indoor Air Quality?

2/22/2008. Indoor Environmental (Air) Quality. Time Spent in Locations: Indoors & Outdoors. Why Should You Care About Indoor Air Quality? Indoor Environmental (Air) Quality Time Spent in Locations: Indoors & Outdoors Unemployed Women Daniel C. Abel CCU Campus and Community Sustainability Initiative www.coastal.edu/sustain October 11, 2006

More information

Indoor Air Quality Program Guide

Indoor Air Quality Program Guide East Carolina University Office of Environmental Health & Safety 210 East Fourth Street Greenville, NC 27858 P: (252) 328-6166 F: (252) 737-1458 www.ecu.edu/oehs Indoor Air Quality Program Guide Date of

More information

Indoor air quality and ventilation

Indoor air quality and ventilation Indoor air quality and ventilation requirements Guangyu Cao (guangyu.cao@ntnu.no) Department of Energy and Process Engineering, NTNU (November, 10, 2016, Hainan, China) Have you used e-clicker or any audience

More information

Introduction. IAQ - 5 School Building Summary 2009

Introduction. IAQ - 5 School Building Summary 2009 Introduction Vortex Inc. was contracted by Ed Collins, [Facilities Director with the Middletown School Dept.] to provide Indoor Air Quality (IAQ) testing within the five (5) school buildings while they

More information

Scope of application. Definitions. Translation from Finnish Legally binding only in Finnish and Swedish Ministry of Social Affairs and Health

Scope of application. Definitions. Translation from Finnish Legally binding only in Finnish and Swedish Ministry of Social Affairs and Health Translation from Finnish Legally binding only in Finnish and Swedish Ministry of Social Affairs and Health Decree of the Ministry of Social Affairs and Health on Health-related Conditions of Housing and

More information

Improve Schools Indoor Environment

Improve Schools Indoor Environment Improve Schools Indoor Environment Indoor Air Quality Tools for Schools Can Save Schools Time and Money What is Indoor Air Quality (IAQ)? Indoor Air Quality refers to environmental characteristics inside

More information

Investigation of indoor climate in a naturally ventilated office building

Investigation of indoor climate in a naturally ventilated office building Indoor Air 2008, 17-22 August 2008, Copenhagen, Denmark - Paper ID: 784 Investigation of indoor climate in a naturally ventilated office building Tine S. Larsen,*, Olena Kalyanova, Rasmus Lund Jensen and

More information

Each participant receives a copy of the presentation power point slides, a walkthrough checklist, additional relevant information and an evaluation.

Each participant receives a copy of the presentation power point slides, a walkthrough checklist, additional relevant information and an evaluation. REFRESHER WORKSHOPS CSIERT offers 2 workshops for TfS teams to assist school districts to sustain their program. The workshops combine elements of the 2 implementation workshops, with an emphasis on IAQ

More information

Illinois Department of Public Health Guidelines for Indoor Air Quality

Illinois Department of Public Health Guidelines for Indoor Air Quality Page 1 of 8 Illinois Department of Public Health Guidelines for Indoor Air Quality Awareness of indoor air quality issues continues to increase throughout Illinois and the country. Studies conducted by

More information

Good (4 points each) > mg/m Bq m Bq m Bq m -3 < ,000 1,000-10,000 10, ,000

Good (4 points each) > mg/m Bq m Bq m Bq m -3 < ,000 1,000-10,000 10, ,000 Rating (5 points each) (4 points each) (3 points each) (2 points each) (1 point each) Temperature ( C) 18-21 C Plus or minus 1 C (including Plus or minus 2 C (including Plus or minus 3 C (including Plus

More information

Analysis of indoor air quality in a store with additional gas heater

Analysis of indoor air quality in a store with additional gas heater Available online at www.worldscientificnews.com WSN 102 (2018) 209-216 EISSN 2392-2192 SHORT COMMUNICATION Analysis of indoor air quality in a store with additional gas heater Monika Wysocka 1, Maciej

More information

Window use in single person offices: do occupants control personal ventilation to provide adequate IAQ? Adorkor Bruce-Konuah 1 University Of Sheffield

Window use in single person offices: do occupants control personal ventilation to provide adequate IAQ? Adorkor Bruce-Konuah 1 University Of Sheffield Window use in single person offices: do occupants control personal ventilation to provide adequate IAQ? Adorkor Bruce-Konuah 1 University Of Sheffield SUMMARY Tests with participants in controlled environments

More information

WHAT IS IEQ? INDOOR ENVIRONMENT QUALITY KEY TO HEALTH & COMFORT A QUESTION WHAT IS SO IMPORTANT ABOUT IAQ? WHAT ELSE IS SO IMPORTANT ABOUT IEQ?

WHAT IS IEQ? INDOOR ENVIRONMENT QUALITY KEY TO HEALTH & COMFORT A QUESTION WHAT IS SO IMPORTANT ABOUT IAQ? WHAT ELSE IS SO IMPORTANT ABOUT IEQ? A QUESTION INDOOR ENVIRONMENT QUALITY KEY TO HEALTH & COMFORT Avinash Kumar Where did you spend the maximum time in the last 24 hours? INDOOR! 2 WHAT IS SO IMPORTANT ABOUT IAQ? WHAT ELSE IS SO IMPORTANT

More information

PERCEIVED AIR QUALITY, THERMAL COMFORT, AND SBS SYMPTOMS AT LOW AIR TEMPERATURE AND INCREASED RADIANT TEMPERATURE

PERCEIVED AIR QUALITY, THERMAL COMFORT, AND SBS SYMPTOMS AT LOW AIR TEMPERATURE AND INCREASED RADIANT TEMPERATURE PERCEIVED AIR QUALITY, THERMAL COMFORT, AND SBS SYMPTOMS AT LOW AIR TEMPERATURE AND INCREASED RADIANT TEMPERATURE J Toftum *, G Reimann, P Foldbjerg, G Clausen and PO Fanger International Centre for Indoor

More information

Chapter 14 Indoor Air Quality

Chapter 14 Indoor Air Quality Chapter 14 Indoor Air Quality 1 Indoor Environment and Built Environment Buildings Transportations vehicles 2 1 Indoor Air Quality (IAQ) Indoor air quality (IAQ) is the quality of air in an indoor environment.

More information

MULTI-CRITERIA ANALYSIS OF HEALTH, COMFORT AND ENERGY-EFFICIENCY OF BUILDINGS

MULTI-CRITERIA ANALYSIS OF HEALTH, COMFORT AND ENERGY-EFFICIENCY OF BUILDINGS MULTI-CRITERIA ANALYSIS OF HEALTH, COMFORT AND ENERGY-EFFICIENCY OF BUILDINGS CA Roulet 1*, N Johner 1, B Oostra 1, F Foradini 2, C Aizlewood 3, C Cox 4 1 Ecole Polytechnique Fédérale, Lausanne, Switzerland

More information

OSHA Act of 1970 Section 5(a)(1) Duties, as may be amended.

OSHA Act of 1970 Section 5(a)(1) Duties, as may be amended. TO: FROM: PREPARED BY: SUBJECT: PPM #: ALL COUNTY PERSONNEL VERDENIA C. BAKER COUNTY ADMINISTRATOR RISK MANAGEMENT INDOOR AIR QUALITY (IAQ) PROGRAM CW-L-037 ====================================================================

More information

DETERMINATION OF VOLATILE ORGANIC COMPOUNDS IN THE BUILDING OF PRINTING COMPANY

DETERMINATION OF VOLATILE ORGANIC COMPOUNDS IN THE BUILDING OF PRINTING COMPANY Proceedings of the 14 th International Conference on Environmental Science and Technology Rhodes, Greece, 3-5 September 2015 DETERMINATION OF VOLATILE ORGANIC COMPOUNDS IN THE BUILDING OF PRINTING COMPANY

More information

COLORADO HEALTHY HOMES

COLORADO HEALTHY HOMES COLORADO HEALTHY HOMES ASHLEY FEIERTAG Energy Outreach Colorado Director of State Programs 3 COLORADO HEALTHY HOMES Today 1. What is a Healthy Home? 2. Why is it important? 3. How do you recognize it?

More information

Indoor Environmental Quality Policy

Indoor Environmental Quality Policy University of Florida Indoor Environmental Quality Policy For New Construction and Renovation Environmental Health and Safety Division June 2009 Introduction Effective management of the indoor environmental

More information

CONCENTRATION OF CARBON DIOXIDE MEASURED IN UNIVERSITY CLASSROOMS

CONCENTRATION OF CARBON DIOXIDE MEASURED IN UNIVERSITY CLASSROOMS CONCENTRATION OF CARBON DIOXIDE MEASURED IN UNIVERSITY CLASSROOMS Katarzyna GŁADYSZEWSKA-FIEDORUK Faculty of Civil and Environmental Engineering, Bialystok University of Technology, Wiejska 45 A, 15-351

More information

AIR QUALITY IN SWINE-FINISHING BARNS 1

AIR QUALITY IN SWINE-FINISHING BARNS 1 Swine Day 2000 Contents AIR QUALITY IN SWINE-FINISHING BARNS 1 B. Z. Predicala 2, R. G. Maghirang 2, R.D. Goodband, S. B. Jerez 2, and J.E. Urban 3 Summary Air quality was assessed in two commercial swine-finishing

More information

VENTILATION 101 WHY VENTILATION IS IMPORTANT IEQ IAQ 10/24/2016 CODE, SYSTEMS, AND IMPACT ON THE LEARNING ENVIRONMENT

VENTILATION 101 WHY VENTILATION IS IMPORTANT IEQ IAQ 10/24/2016 CODE, SYSTEMS, AND IMPACT ON THE LEARNING ENVIRONMENT VENTILATION 101 CODE, SYSTEMS, AND IMPACT ON THE LEARNING ENVIRONMENT WHY VENTILATION IS IMPORTANT Americans spend 90% of their time indoors, where concentrations of pollutants are 2-5x higher than outdoors,

More information

2016 Nitrogen Dioxide Summary

2016 Nitrogen Dioxide Summary 2016 Nitrogen Dioxide Summary New Jersey Department of Environmental Protection SOURCES Nitrogen dioxide (NO2) is a reddish-brown highly reactive gas that is formed in the air through the oxidation of

More information

TN Tatem Middle School Indoor Air Quality Assessment September 2016

TN Tatem Middle School Indoor Air Quality Assessment September 2016 TN Tatem Middle School Indoor Air Quality Assessment September 2016 Completed by Island Air Quality Services P.O. Box SN139 Southampton SNBX Bermuda Table of Contents 1 Report Summary... 1 2 Introduction

More information

Report of Limited Indoor Air Quality Services

Report of Limited Indoor Air Quality Services Report of Limited Indoor Air Quality Services Lincoln School 1601 State Street Harrisburg, Pennsylvania 17103 Prepared For: Harrisburg School District 1601 State Street Harrisburg, Pennsylvania 17103 February

More information

VOCs) For more information, see EPA's Substance Registry System on VOCs. Contents

VOCs) For more information, see EPA's Substance Registry System on VOCs. Contents Volatile organic compounds (VOCs) are emitted as gases from certain solids or liquids. VOCs include a variety of chemicals, some of which may have short- and long-term adverse health effects. Concentrations

More information

AIR FILTRATION in HVAC Systems

AIR FILTRATION in HVAC Systems 11.as Jornadas de Climatização 2011 October 13 th AIR FILTRATION in HVAC Systems REHVA GUIDEBOOK NO 11 Jan Gustavsson Sweden Copyright/jg 2011-10-09 1 Filtration Guidebook Aimed for designers, manufacturers,

More information

EN ISO A more precise filter standard helps ensure air quality

EN ISO A more precise filter standard helps ensure air quality EN ISO 16890- A more precise filter standard helps ensure air quality The International Standard Organisation ISO has issued a new global standard for the filtering and testing of filters ISO 16890, specifying

More information

INDOOR AIR QUALITY AND PREVALENCE OF SICK BUILDING SYNDROME AMONG OFFICE WORKERS IN TWO DIFFERENT OFFICES IN SELANGOR

INDOOR AIR QUALITY AND PREVALENCE OF SICK BUILDING SYNDROME AMONG OFFICE WORKERS IN TWO DIFFERENT OFFICES IN SELANGOR American Journal of Applied Sciences 10 (10): 1140-1147, 2013 ISSN: 1546-9239 2013 Science Publication doi:10.3844/ajassp.2013.1140.1147 Published Online 10 (10) 2013 (http://www.thescipub.com/ajas.toc)

More information

Washington State Department of Health Division of Environmental Health

Washington State Department of Health Division of Environmental Health Washington State Department of Health Division of Environmental Health School Indoor Air Quality Monitoring Project Washington Resource Conservation Manager (RCM) Meeting July 19, 2007 Washington Middle

More information

INVESTIGATION OF INDOOR ENVIRONMENTAL QUALITY AND PRODUCTIVITY IN MONITORED OFFICES IN SLOVAKIA

INVESTIGATION OF INDOOR ENVIRONMENTAL QUALITY AND PRODUCTIVITY IN MONITORED OFFICES IN SLOVAKIA Proceedings of the 14 th International Conference on Environmental Science and Technology Rhodes, Greece, 3-5 September 2015 INVESTIGATION OF INDOOR ENVIRONMENTAL QUALITY AND PRODUCTIVITY IN MONITORED

More information

STUDY ON SICK BUILDING SYNDROME IN OFFICE ENVIRONMENT

STUDY ON SICK BUILDING SYNDROME IN OFFICE ENVIRONMENT STUDY ON SICK BUILDING SYNDROME IN OFFICE ENVIRONMENT H. A. N. Wijerathne, G. I. Karunasena* and B. H. Mallawaarachchi Department of Building Economics, University of Moratuwa, Sri Lanka ABSTRACT Prevalence

More information

6560 Northwest Drive Mississauga, ON L4V 1P2 Tel: **EMERGENCY OVERVIEW**

6560 Northwest Drive Mississauga, ON L4V 1P2 Tel: **EMERGENCY OVERVIEW** 1. CHEMICAL AND COMPANY IDENTIFICATION NAME : APPLICATION/RESTRICTIONS : COMPANY IDENTIFICATION : EMERGENCY TELEPHONE NUMBER(S) : COLUMBIA-MBF 6560 Northwest Drive Mississauga, ON L4V 1P2 Tel: 905-362-0180

More information

Overview of Dynamic Control of Lab ACH s

Overview of Dynamic Control of Lab ACH s A Comprehensive Review of the Indoor Environmental Quality and Energy Impacts of Dynamically Varying Air Change Rates at Multiple Laboratory Facilities Overview of Dynamic Control of Lab ACH s Background

More information

Healthy Learning Environment

Healthy Learning Environment Healthy Learning Environment Introduction: A major issue facing the construction industry today is creating a healthy learning environment for school buildings. Healthy learning environments are crucial

More information