EPA Method 1 Field Procedures Example:

Size: px
Start display at page:

Download "EPA Method 1 Field Procedures Example:"

Transcription

1 EPA Method 1 Field Procedures Step Instruction 100 Is the stack or duct circular or square/rectangle? If square/rectangular go to step Determine the diameter of the stack from one of the following methods. a. Review drawings of stack b. If the stack has been tested previously, determine diameter from previous test. c. Measure the inside diameter with a rigid tube or pipe from the sampling ports on two axis and average the diameter. Be sure to subtract the distance from the inside wall to the end of the sample port, this is your reference value. d. Measure the circumference and calculate the inside diameter, less the wall thickness times two. 110 Measure the distance from the sampling ports downstream to the nearest disturbance. A disturbance is a bend in the ductwork, transition from square to round duct shape, a fan, or some other disturbance such as the stack exit, that may cause the flow not be uniform. 120 Measure the distance from the sampling ports upstream to the nearest disturbance. 125 Determine the duct diameters upstream from the flow disturbance. Determine the duct diameters downstream from the flow disturbance. 130 Reference the chart below to determine the minimum number of required sample points. 135 Example: Stack diameter 18, distance from ports to downstream disturbance is 24 and distance from ports to upstream disturbance 72. Duct diameters upstream from flow disturbance (Distance B) is 24 / 18 = 1.3. Duct diameters upstream from flow disturbance (Distance A) is 72 / 18 =

2 140 Distance B requires 20 sample points and Distance A requires 24 sample points. The number of required sample points will be 24 since Distance A requires more sample points. 145 Locate the sample points using the following chart. Stacks having diameters greater than 0.61 m (24 in.), no traverse points shall be within 2.5 centimeters (1.00 in.) of the stack walls; and for stack diameters equal to or less than 0.61 m (24 in.), no traverse points shall be located within 1.3 cm (0.50 in.) of the stack walls. When any of the traverse points as located fall within 2.5 cm (1.0 in.) of the stack walls, relocate them away from the stack walls to: (1) a distance of 2.5 cm (1.0 in.); or (2) a distance equal to the nozzle inside diameter, whichever is larger. These relocated traverse points (on each end of a diameter) shall be the adjusted traverse points. Whenever two successive traverse points are combined to form a single adjusted traverse point, treat the adjusted point as two separate traverse points, both in the sampling and/or velocity measurement procedure, and in recording of the data. Stacks With Diameters Equal To or Less Than 0.61 m (24 in.). Follow the procedure in Section , noting only that any adjusted points should be relocated away from the stack walls to: (1) a distance of 1.3 cm (0.50 in.); or (2) a distance equal to the nozzle inside diameter, whichever is larger

3 150 Example: Using the information from the example in Step 135 and assuming the distance from the inside wall to the end of the sample port as 5 inches (reference), the sample point on a diameter (traverse) would be the following. (% diameter X diameter + reference value). Sample Point 12 Distance from inside wall Correction With Reference Stack diameter is 18 inches, reference 5 inches, distance from ports to downstream disturbance is 24 and distance from ports to upstream disturbance 72. Duct diameters upstream from flow disturbance (Distance B) is 24 / 18 = 1.3. Duct diameters upstream from flow disturbance (Distance A) is 72 / 18 = 4.0. Total sample points are 24, 12 per diameter (traverse). Note: Sample points 1 & 12 must be relocated. The stack diameter is less than 24 inches, thus no sample point should be closer than 0.5 from the inside wall, see step Use wrappings of glass electrical tape, or other suitable means to clearly mark each sample point on the probe. During testing begin at point 1 and progressively move to the next point when finished at that point. Repeat until all points on the traverse have been sampled. Move to the other sampling point and repeat the process. 160 In most stationary sources, the direction of stack gas flow is essentially parallel to the stack walls. However, cyclonic flow may exist (1) after such devices as cyclones and inertial demisters following venturi scrubbers, or (2) in stacks having tangential inlets or other duct configurations which tend to induce swirling; in these instances, the presence or absence of cyclonic flow at the sampling location must be determined. The following techniques are acceptable for this determination. Level and zero the manometer. Connect a Type S pitot tube to the manometer and leakcheck system. Position the Type S pitot tube at each traverse point, in succession, so that the planes of the face openings of the pitot tube are perpendicular to the stack crosssectional plane; when the Type S pitot tube is in this position, it is at 0 reference. Note the differential pressure (Δp) reading at each traverse point. If a null (zero) pitot reading is obtained at 0 reference at a given traverse point, an acceptable flow condition exists at that point. If the pitot reading is not zero at 0 reference, rotate the pitot tube (up to ±90-3 -

4 yaw angle), until a null reading is obtained. Carefully determine and record the value of the rotation angle (α) to the nearest degree. After the null technique has been applied at each traverse point, calculate the average of the absolute values of α; assign α values of 0 to those points for which no rotation was required, and include these in the overall average. If the average value of α is greater than 20, the overall flow condition in the stack is unacceptable, and alternative methodology, subject to the approval of the Administrator, must be used to perform accurate sample and velocity traverses. Square / Rectangular Ducts & Stacks 170 Determine the duct or stack dimensions, width and length from one of the following methods. a. Review drawings of stack b. If the stack has been tested previously, determine dimensions from previous test. c. Measure the inside dimensions, width and length. Width Length 175 In the case of rectangular ducts, an equivalent diameter, D e is used in the siting and traverse point considerations. For a rectangular duct, use the following equation to determine the equivalent diameter, De. De = 2LW (L+W) Where: L = length of the duct W = width of the duct 180 Measure the distance from the sampling ports downstream to the nearest disturbance. A disturbance is a bend in the ductwork, transition from square to round duct shape, a fan, or some other disturbance such as the stack exit, that may cause the flow not be uniform. 185 Measure the distance from the sampling ports upstream to the nearest disturbance. 190 Determine the duct diameters upstream from the flow disturbance. Determine the duct diameters downstream from the flow disturbance. If the duct or stack is rectangular, use the equivalent diameter De in calculating the duct diameters

5 195 Reference the chart below to determine the minimum number of required sample points. 200 Example: Stack is 24 wide by 36 long (rectangular), distance from ports to downstream disturbance is 75 and distance from ports to upstream disturbance 190. Equivalent diameter is Assume that there are 4 sample ports on the 36 side of the duct. Duct diameters upstream from flow disturbance (Distance B) is 75 / 28.8 = 2.6. Duct diameters upstream from flow disturbance (Distance A) is 190 / 28.8 = Distance B requires 12 sample points and Distance A requires 16 sample points. The number of required sample points will be 16, since Distance A requires more sample points

6 210 Locate the sample points using the following chart for square and rectangular stacks and ducts. Stacks having diameters greater than 0.61 m (24 in.), no traverse points shall be within 2.5 centimeters (1.00 in.) of the stack walls; and for stack diameters equal to or less than 0.61 m (24 in.), no traverse points shall be located within 1.3 cm (0.50 in.) of the stack walls. When any of the traverse points as located fall within 2.5 cm (1.0 in.) of the stack walls, relocate them away from the stack walls to: (1) a distance of 2.5 cm (1.0 in.); or (2) a distance equal to the nozzle inside diameter, whichever is larger. These relocated traverse points (on each end of a diameter) shall be the adjusted traverse points. Whenever two successive traverse points are combined to form a single adjusted traverse point, treat the adjusted point as two separate traverse points, both in the sampling and/or velocity measurement procedure, and in recording of the data. Stacks With Diameters Equal To or Less Than 0.61 m (24 in.). Follow the procedure in Section , noting only that any adjusted points should be relocated away from the stack walls to: (1) a distance of 1.3 cm (0.50 in.); or (2) a distance equal to the nozzle inside diameter, whichever is larger

7 215 Example: Using the information from the example in Step 200 and assuming the distance from the inside wall to the end of the sample port as 4.5 inches (reference)., the sample point on a diameter (traverse) would be the following. (% diameter X diameter + reference value). Sample Point Placement in Rectangular Stack Port Length 4.5" Sample Ports Percent of Diameter Distance from inside Wall Distance with Reference 24" 12.5% % % % " 220 Use wrappings of glass electrical tape, or other suitable means to clearly mark each sample point on the probe. During testing begin at point 1 and progressively move to the next point when finished at that point. Repeat until all points on the traverse have been sampled. Move to the other sampling point and repeat the process. 225 In most stationary sources, the direction of stack gas flow is essentially parallel to the stack walls. However, cyclonic flow may exist (1) after such devices as cyclones and inertial demisters following venturi scrubbers, or (2) in stacks having tangential inlets or other duct configurations which tend to induce swirling; in these instances, the presence or absence of cyclonic flow at the sampling location must be determined. The following techniques are acceptable for this determination. Level and zero the manometer. Connect a Type S pitot tube to the manometer and leakcheck system. Position the Type S pitot tube at each traverse point, in succession, so that the planes of the face openings of the pitot tube are perpendicular to the stack crosssectional plane; when the Type S pitot tube is in this position, it is at 0 reference. Note the differential pressure (Δp) reading at each traverse point. If a null (zero) pitot reading is obtained at 0 reference at a given traverse point, an acceptable flow condition exists at that point. If the pitot reading is not zero at 0 reference, rotate the pitot tube (up to ±90 yaw angle), until a null reading is obtained. Carefully determine and record the value of - 7 -

8 the rotation angle (α) to the nearest degree. After the null technique has been applied at each traverse point, calculate the average of the absolute values of α; assign α values of 0 to those points for which no rotation was required, and include these in the overall average. If the average value of α is greater than 20, the overall flow condition in the stack is unacceptable, and alternative methodology, subject to the approval of the Administrator, must be used to perform accurate sample and velocity traverses

METHOD 1A - SAMPLE AND VELOCITY TRAVERSES FOR STATIONARY SOURCES WITH SMALL STACKS OR DUCTS. NOTE: This method does not include all of the

METHOD 1A - SAMPLE AND VELOCITY TRAVERSES FOR STATIONARY SOURCES WITH SMALL STACKS OR DUCTS. NOTE: This method does not include all of the 206 METHOD 1A - SAMPLE AND VELOCITY TRAVERSES FOR STATIONARY SOURCES WITH SMALL STACKS OR DUCTS NOTE: This method does not include all of the specifications (e.g., equipment and supplies) and procedures

More information

COOLING TECHNOLOGY INSTITUTE

COOLING TECHNOLOGY INSTITUTE PAPER NO: CATEGORY: TP18-23 TESTING COOLING TECHNOLOGY INSTITUTE COMPARATIVE EVALUATION OF PITOT TUBE DESIGNS FOR WATER FLOW MEASUREMENT DEVICES KENNETH W. HENNON, P.E. DAVID E. WHEELER, P.E. CLEANAIR

More information

METHOD 2 - DETERMINATION OF STACK GAS VELOCITY AND VOLUMETRIC FLOW RATE (TYPE S PITOT TUBE) NOTE: This method does not include all of the

METHOD 2 - DETERMINATION OF STACK GAS VELOCITY AND VOLUMETRIC FLOW RATE (TYPE S PITOT TUBE) NOTE: This method does not include all of the 214 METHOD 2 - DETERMINATION OF STACK GAS VELOCITY AND VOLUMETRIC FLOW RATE (TYPE S PITOT TUBE) NOTE: This method does not include all of the specifications (e.g., equipment and supplies) and procedures

More information

MEASUREMENT OF AIRFLOW

MEASUREMENT OF AIRFLOW MEMORIAL UNIVERSITY OF NEWFOUNLAN Faculty of Engineering and Applied Science FLUI MECHANICS LABORATORY Spring 003 MEASUREMENT OF AIRFLOW Objective To measure air flow-rate using three different techniques.

More information

Emissions Testing Report 2014

Emissions Testing Report 2014 Orora Limited 09-Apr-2014 Emissions Testing Report 2014 Orora Limited NATA ACCREDITATION No. 2778 (14391) Accredited for compliance with ISO/IEC 17025 This document is issued in accordance with NATA s

More information

Emissions Testing Report 2015

Emissions Testing Report 2015 Orora Limited 20-Jul-2015 Emissions Testing Report 2015 Orora Limited NATA ACCREDITATION No. 2778 (14391) Accredited for compliance with ISO/IEC 17025 This document is issued in accordance with NATA s

More information

NC DAQ Source Test Observers Checklist - Particulate Testing EPA Methods 1-5 (40 CFR 60 Appendix A) Line by line explanation and references.

NC DAQ Source Test Observers Checklist - Particulate Testing EPA Methods 1-5 (40 CFR 60 Appendix A) Line by line explanation and references. NC DAQ Source Test Observers Checklist - Particulate Testing EPA Methods 1-5 (40 CFR 60 Appendix A) Line by line explanation and references. This checklist is not intended to replace familiarity with the

More information

METHOD BERYLLIUM SCREENING METHOD. Analyte CAS No. Sensitivity Beryllium (Be) Dependent upon analytical procedure used

METHOD BERYLLIUM SCREENING METHOD. Analyte CAS No. Sensitivity Beryllium (Be) Dependent upon analytical procedure used 1764 METHOD 103 - BERYLLIUM SCREENING METHOD 1.0 Scope and Application. 1.1 Analytes. Analyte CAS No. Sensitivity Beryllium (Be) 7440-41-7 Dependent upon analytical procedure used 1.2 Applicability. This

More information

2nd Quarter Emissions Testing Report 2013

2nd Quarter Emissions Testing Report 2013 OneSteel Recycling Pty Ltd 17-Jul-2013 60290660 Commercial-in-Confidence 2nd Quarter Emissions Testing Report 2013 OneSteel Recycling Hexham NATA ACCREDITATION No. 2778 (14391) Accredited for compliance

More information

4th Quarter Emissions Testing Report 2015

4th Quarter Emissions Testing Report 2015 OneSteel Recycling Pty Ltd Doc No. 60290660_3.1_Q4 Commercial-in-Confidence 4th Quarter Emissions Testing Report 2015 OneSteel Recycling Hexham NATA ACCREDITATION No. 2778 (14391) Accredited for compliance

More information

Method Implementation Document for BS EN * - Application to manual stack emissions monitoring

Method Implementation Document for BS EN * - Application to manual stack emissions monitoring Method Implementation Document for BS EN 16911-1* - Application to manual stack emissions monitoring *BS EN ISO 16911-1:2013 Stationary source emissions - Manual and automatic determination of velocity

More information

Not Just a Lot of Hot Air!

Not Just a Lot of Hot Air! Not Just a Lot of Hot Air! In-line calibrating an Annubar Primary Flow Element in unconventional ductwork or plumbing. Short Course: 6A-4890 Photography & Video Recording Policy Photography and audio/video

More information

DETERMINATION OF CONCENTRATION AND MASS FLOW OF PARTICULATE MATTER IN FLUE GAS FOR STATIONARY SOURCE EMISSIONS

DETERMINATION OF CONCENTRATION AND MASS FLOW OF PARTICULATE MATTER IN FLUE GAS FOR STATIONARY SOURCE EMISSIONS MS 1596: 2003 DETERMINATION OF CONCENTRATION AND MASS FLOW OF PARTICULATE MATTER IN FLUE GAS FOR STATIONARY SOURCE EMISSIONS Presented BY: UiTM A&A Laboratory Malaysia s 1 st University Affiliated Environmental

More information

2nd Quarter Emissions Testing Report 2017

2nd Quarter Emissions Testing Report 2017 OneSteel 2nd Quarter Recycling Emissions Pty Testing Ltd Report 2017 20-Jun-2017 Doc No. 60493017_2.1_Q2_2017 2nd Quarter Emissions Testing Report 2017 OneSteel Recycling Hexham NATA ACCREDITATION No.

More information

4th Quarter Emissions Testing Report 2016

4th Quarter Emissions Testing Report 2016 4th Quarter Emissions Testing Report 2016 OneSteel Recycling Pty Ltd Doc No. 60493017_1.1_Q4_2016 4th Quarter Emissions Testing Report 2016 OneSteel Recycling Hexham NATA ACCREDITATION No. 2778 (14391)

More information

EXPERIMENTAL AERODYNAMICS FLOW TROUGH AN ORIFICE LAB SHEET

EXPERIMENTAL AERODYNAMICS FLOW TROUGH AN ORIFICE LAB SHEET EXPERIMENTAL AERODYNAMICS FLOW TROUGH AN ORIFICE LAB SHEET EMRE KOÇ ONUR GÜNEL 1- Introduction When a fluid passes through a constriction, such as through a sharp-edged hole or over a weir, the constriction

More information

3rd Quarter Emissions Testing Report 2018

3rd Quarter Emissions Testing Report 2018 OneSteel 3rd Quarter Recycling Emissions Pty Testing Ltd Report 2018 Commercial-in-Confidence Doc Commercial-in-Confidence No. 60493017_3.1_Q3_2018 60493017 3rd Quarter Emissions Testing Report 2018 OneSteel

More information

2nd Quarter Emissions Testing Report 2016

2nd Quarter Emissions Testing Report 2016 OneSteel Recycling Pty Ltd Doc No. 60493017_1.2_Q2_2016 Commercial-in-Confidence 2nd Quarter Emissions Testing Report 2016 OneSteel Recycling Hexham NATA ACCREDITATION No. 2778 (14391) Accredited for compliance

More information

Test Report TR1R0

Test Report TR1R0 1 CLIENT DETAILS Organisation: Company Contact: Cogent Energy Pty Ltd Eoghain Maguire Site Address: 101-103 Miller Street, North Sydney NSW 2060 Postal Address: Suite 2, Level 9, 1 Chandos Street, St Leonards

More information

3rd Quarter Emissions Testing Report 2016

3rd Quarter Emissions Testing Report 2016 3rd Quarter Emissions Testing Report 2016 OneSteel Recycling Pty Ltd Doc No. 60493017_1.1_Q3_2016 3rd Quarter Emissions Testing Report 2016 OneSteel Recycling Hexham NATA ACCREDITATION No. 2778 (14391)

More information

Test Report TR1R1

Test Report TR1R1 1 CLIENT DETAILS Organisation: Company Contact: Origin Energy Services Ltd Eoghain Maguire Site Address: 101-103 Miller Street, North Sydney NSW 2060 Postal Address: Level 7, 321 Exhibition Street, Melbourne

More information

Experimental Analysis of Flow through Rotating Swirler with Effect of Guide Vane

Experimental Analysis of Flow through Rotating Swirler with Effect of Guide Vane Experimental Analysis of Flow through Rotating Swirler with Effect of Guide Vane Mansha kumari 1, Shah Jagruti 2, Arvind.S.Mohite 3 M.E. (JPGTP)Student, Department of mechanical engineering, Faculty of

More information

Study of flow through combustion swirler with the effect of diffuser on the recirculation zone

Study of flow through combustion swirler with the effect of diffuser on the recirculation zone International Journal of Engineering Research and Development e-issn: 2278-067X, p-issn: 2278-800X, www.ijerd.com Volume 3, Issue 6 (September 2012), PP. 68-73 Study of flow through combustion swirler

More information

Flow Measurement in Large Ducts & Pipes

Flow Measurement in Large Ducts & Pipes Flow Measurement in Large Ducts & Pipes A. S. Murali Deputy Director C. B.Suresh Sr. Research Engineer (Fluid Control Research Institute, Kanjikode West, Palakad, 678 623, Kerala, India) ABSTRACT Flow

More information

Experimental Analysis Of Flow Through Rotating Combustion Swirler With Zero Degree Inlet and Outlet Angle Of Guide Vane

Experimental Analysis Of Flow Through Rotating Combustion Swirler With Zero Degree Inlet and Outlet Angle Of Guide Vane Experimental Analysis Of Flow Through Rotating Combustion Swirler With Zero Degree Inlet and Outlet Angle Of Guide Vane MANSHA KUMARI Department of Mechanical Engineering, Faculty of Technology & Engineering,

More information

Measuring Air Velocity - presented by Lonnie Glen, Kice Industries 2/28/2018. (and why it is important) Applications for Air

Measuring Air Velocity - presented by Lonnie Glen, Kice Industries 2/28/2018. (and why it is important) Applications for Air (and why it is important) Wednesday, February 28, 2018 Presented by Lonnie Glen, Kice Technical Sales and Quickship Manager Applications for Air Air Activated Processing Grinders Granulators Hammermills

More information

Dan Deatsch Thompson Environmental Consulting

Dan Deatsch Thompson Environmental Consulting Dan Deatsch Thompson Environmental Consulting Three methods for testing particulate matter emissions Method 5 and d17 Particulate t Matter Emissions i Method 201A PM10 and PM2.5 Emissions Method 202 Condensable

More information

Experimental Analysis Of Flow Through Rotating Swirler In Combustion Chamber

Experimental Analysis Of Flow Through Rotating Swirler In Combustion Chamber Experimental Analysis Of Flow Through Rotating Swirler In Combustion Chamber Mansha kumari 1, Shah Jagruti 2 M.E. (JPGTP)Student,Department of mechanical engineering, Faculty of technology & engineering,

More information

ISO 3966 INTERNATIONAL STANDARD. Measurement of fluid flow in closed conduits Velocity area method using Pitot static tubes

ISO 3966 INTERNATIONAL STANDARD. Measurement of fluid flow in closed conduits Velocity area method using Pitot static tubes INTERNATIONAL STANDARD ISO 3966 Second edition 2008-07-15 Measurement of fluid flow in closed conduits Velocity area method using Pitot static tubes Mesurage du débit des fluides dans les conduites fermées

More information

Lecture 26. Contents: Exercise 1. Exercise 2. Exercise 3

Lecture 26. Contents: Exercise 1. Exercise 2. Exercise 3 Lecture 26 Contents: Exercise 1 Exercise 2 Exercise 3 Key Words: Fluid flow, Macroscopic Balance, Frictional Losses, Turbulent Flow, Venturimeter, Orifice Meter, Pitot Tube, Stack, Chimney, raft, Natural

More information

PART B AIR AND AIR EMISSIONS TESTING

PART B AIR AND AIR EMISSIONS TESTING PART B AIR AND AIR EMISSIONS TESTING Her Majesty the Queen in Right of the Province of British Columbia 2013 All Rights Reserved HIVOL SAMPLING TO ASSESS CHRONIC HAZARD OF TRACE METALS IN AIR PARTICULATES

More information

METHOD 17 - DETERMINATION OF PARTICULATE MATTER EMISSIONS FROM STATIONARY SOURCES. NOTE: This method does not include all of the

METHOD 17 - DETERMINATION OF PARTICULATE MATTER EMISSIONS FROM STATIONARY SOURCES. NOTE: This method does not include all of the 1035 METHOD 17 - DETERMINATION OF PARTICULATE MATTER EMISSIONS FROM STATIONARY SOURCES NOTE: This method does not include all of the specifications (e.g., equipment and supplies) and procedures (e.g.,

More information

CASE STUDIES OF DUST AMS CALIBRATION AT EXTREME CONDITIONS

CASE STUDIES OF DUST AMS CALIBRATION AT EXTREME CONDITIONS CASE STUDIES OF DUST AMS CALIBRATION AT EXTREME CONDITIONS Jurij ČRETNIK RACI d.o.o., Tehnološki park 24, SI-1000 LJUBLJANA, SLOVENIA jurij.cretnik@raci.si Matjaž ŠLIBAR RACI d.o.o., Tehnološki park 24,

More information

Problems with Pitots. Issues with flow measurement in stacks.

Problems with Pitots. Issues with flow measurement in stacks. CEM-2004 Problems with Pitots. Issues with flow measurement in stacks. R A Robinson 1, D Butterfield 1, D Curtis 2, T Thompson 3 1 National Physical Laboratory Queens Road Teddington Middlesex TW11 0AX

More information

Emissions Testing Report

Emissions Testing Report National Ceramic Industries Australia 05-May-2014 60305580 Commercial-in-Confidence Emissions Testing Report 2013-14 National Ceramic Industries Australia NATA ACCREDITATION No. 2778 (14391) Accredited

More information

EXAMPLE: TEST PLAN FOR SOLVENT BASED PRINTING & COATING PROCESS SOURCES

EXAMPLE: TEST PLAN FOR SOLVENT BASED PRINTING & COATING PROCESS SOURCES EXAMPLE: TEST PLAN FOR SOLVENT BASED PRINTING & COATING PROCESS SOURCES Proposed test date(s): (Test plan postmark or e-mail date triggers 30 day notification period) PART I. GENERAL INFORMATION 1. Name

More information

GENERAL TESTING AND REPORTING REQUIREMENTS

GENERAL TESTING AND REPORTING REQUIREMENTS GENERAL TESTING AND REPORTING REQUIREMENTS Ohio EPA requires that an Ohio Intent to Test ( ITT ) form be filed with the appropriate Ohio EPA representative at least 30 days (or more if required by regulation)

More information

SECTION DUCTS PART 1 GENERAL 1.01 SUMMARY

SECTION DUCTS PART 1 GENERAL 1.01 SUMMARY 1 1 1 1 1 1 1 1 0 1 0 1 SECTION 1 DUCTS PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Duct Materials.. Insulated flexible ducts.. Single wall spiral round ducts.. Ductwork fabrication.. Duct cleaning.

More information

Alabama Department of Environmental Management Air Division Planning Branch Emission Measurement Section

Alabama Department of Environmental Management Air Division Planning Branch Emission Measurement Section Alabama Department of Environmental Management Air Division Planning Branch Emission Measurement Section Particulate Sampling Guideline & Reporting Format Revision No. 6 December 2003 PARTICULATE SAMPLING

More information

HX Performance Testing

HX Performance Testing Nuclear Division HX Performance Testing FSRUG January 26, 2016 1 February 3, 2016 2014 Curtiss-Wright Agenda Why Heat Exchanger Performance Testing (HXPT) is required GL 89-13 Overview Typical HXPT Methodology

More information

METHOD 2C - DETERMINATION OF GAS VELOCITY AND VOLUMETRIC FLOW RATE IN SMALL STACKS OR DUCTS (STANDARD PITOT TUBE)

METHOD 2C - DETERMINATION OF GAS VELOCITY AND VOLUMETRIC FLOW RATE IN SMALL STACKS OR DUCTS (STANDARD PITOT TUBE) 274 METHOD 2C - DETERMINATION OF GAS VELOCITY AND VOLUMETRIC FLOW RATE IN SMALL STACKS OR DUCTS (STANDARD PITOT TUBE) NOTE: This method does not include all of the specifications (e.g., equipment and supplies)

More information

Determination of the Ethylene Oxide Control Efficiency from Catalytic Oxidizers. A Guidance Document

Determination of the Ethylene Oxide Control Efficiency from Catalytic Oxidizers. A Guidance Document Determination of the Ethylene Oxide Control Efficiency from Catalytic Oxidizers A Guidance Document Report EC 1/RM/5 July 007 Readers Comments Inquiries pertaining to the use of this document should be

More information

METHOD 4 - DETERMINATION OF MOISTURE CONTENT IN STACK GASES. NOTE: This method does not include all the

METHOD 4 - DETERMINATION OF MOISTURE CONTENT IN STACK GASES. NOTE: This method does not include all the 347 METHOD 4 - DETERMINATION OF MOISTURE CONTENT IN STACK GASES NOTE: This method does not include all the specifications (e.g., equipment and supplies) and procedures (e.g., sampling) essential to its

More information

Chapter 15. Air Monitoring. Source Sampling

Chapter 15. Air Monitoring. Source Sampling Chapter 5 Air Monitoring Source Sampling A representative sample is the key to the accurate measurement of emissions from a source. Different source test methods have been developed for a variety of realistic

More information

DEPARTMENT OF CIVIL ENGINEERING CE6403/ APPLIED HYDRAULIC ENGINEERING QUESTION BANK TWO MARKS UNIT I UNIFORM FLOW 1. Differentiate open channel flow from pipe flow. 2. What is specific energy and is the

More information

HDPE PERFORATION GUIDE PERFORATIONS PER AASHTO M252/M294

HDPE PERFORATION GUIDE PERFORATIONS PER AASHTO M252/M294 PERFORATIONS GENERAL Lane s perforated pipe offerings follow the AASHTO classification system and conform to AASHTO requirements for size, spacing and placement of the perforations. It is not the intent

More information

Chapter 10. Conduit Outlet Structures Introduction General Layout Information

Chapter 10. Conduit Outlet Structures Introduction General Layout Information 10.0 Introduction This section addresses the design of culvert outlets, which are typically oriented in-line with the flow in a drainageway, and storm sewer outlets, which are typically oriented perpendicular

More information

Optimization of Sensor Locations for Measurement of Flue Gas Flow in Industrial Ducts and Stacks Using Neural Networks

Optimization of Sensor Locations for Measurement of Flue Gas Flow in Industrial Ducts and Stacks Using Neural Networks 228 IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, VOL. 49, NO. 2, APRIL 2000 Optimization of Sensor Locations for Measurement of Flue Gas Flow in Industrial Ducts and Stacks Using Neural Networks

More information

REDUCE FLOW BIAS THROUGH AUTOMATED TESTING

REDUCE FLOW BIAS THROUGH AUTOMATED TESTING REDUCE FLOW BIAS THROUGH AUTOMATED TESTING PRESENTED AT: THE 20 TH ANNUAL ELECTRIC UTILITY CHEMISTRY WORKSHOP AT THE UNIVERSITY OF ILLINOIS MAY 9 11, 2000 CLARION HOTEL AND CONVENTION CENTER CHAMPAIGN,

More information

METHOD 201A - DETERMINATION OF PM EMISSIONS. 1.1 Applicability. This method applies to the in-stack measurement of

METHOD 201A - DETERMINATION OF PM EMISSIONS. 1.1 Applicability. This method applies to the in-stack measurement of EMISSION MEASUREMENT TECHNICAL INFORMATION CENTER TEST METHOD METHOD 201A - DETERMINATION OF PM EMISSIONS (Constant Sampling Rate Procedure) 1. Applicability and Principle 1.1 Applicability. This method

More information

Comparison of Dry Sorbent Injection of Sodium Bicarbonate, Lime, and Carbon and Their Control of Dioxins/Furans, Mercury, Chlorides and Sulfur Dioxide

Comparison of Dry Sorbent Injection of Sodium Bicarbonate, Lime, and Carbon and Their Control of Dioxins/Furans, Mercury, Chlorides and Sulfur Dioxide Comparison of Dry Sorbent Injection of Sodium Bicarbonate, Lime, and and Their Control of Dioxins/Furans, Mercury, Chlorides and Sulfur Dioxide Acid Gas and Toxics Removal at WCA Hospital, Jamestown, NY

More information

Method X: Determination of Metal Concentrations in Emissions from Stationary Sources (Instrumental Analyzer Procedure)

Method X: Determination of Metal Concentrations in Emissions from Stationary Sources (Instrumental Analyzer Procedure) Method X: Determination of Metal Concentrations in Emissions from Stationary Sources (Instrumental Analyzer Procedure) June 7, 2005 Submitted to: The Environmental Protection Agency Research Triangle Park,

More information

Universities of Leeds, Sheffield and York

Universities of Leeds, Sheffield and York promoting access to White Rose research papers Universities of Leeds, Sheffield and York http://eprints.whiterose.ac.uk/ This is an author produced version of a paper published in Sensor Review. White

More information

FLUID MECHANICS PROF. DR. METİN GÜNER COMPILER

FLUID MECHANICS PROF. DR. METİN GÜNER COMPILER FLUID MECHANICS PROF. DR. METİN GÜNER COMPILER ANKARA UNIVERSITY FACULTY OF AGRICULTURE DEPARTMENT OF AGRICULTURAL MACHINERY AND TECHNOLOGIES ENGINEERING 1 4. ELEMENTARY FLUID DYNAMICS -THE BERNOULLI EQUATION

More information

SMACNA-01Accepted Industry Practice for Industrial Duct Construction. A. Duct work sizes on drawings state inside clear dimensions.

SMACNA-01Accepted Industry Practice for Industrial Duct Construction. A. Duct work sizes on drawings state inside clear dimensions. 15XXX - 1 Section 15XXX : CORROSIVE EXHAUST DUCT WORK PART 1GENERAL 1.1 REFERENCES SMACNA-01Accepted Industry Practice for Industrial Duct Construction SMACNA-06HVAC Duct Construction Standards SMACNARound

More information

`Limit State of Collapse in Compression Design of an Axially Loaded Short Column

`Limit State of Collapse in Compression Design of an Axially Loaded Short Column `Limit State of Collapse in Compression Design of an Axially Loaded Short Column Cl.39, p-70, IS:456-2000 Members in compression are called columns and struts. The term column is reserved for members which

More information

Air Division. Emissions Test Protocol And Test Report Requirements

Air Division. Emissions Test Protocol And Test Report Requirements Air Division Emissions Test Protocol And Test Report Requirements May 18, 2018 Introduction The purpose of this document is to provide guidance for test protocols and reporting stack tests under the jurisdiction

More information

Flow Meter Calibration

Flow Meter Calibration fluid mechanics H4 A compact unit that compares and shows the accuracy, losses and use of fundamental flow meters Key Features Unique quick-change flow meter adaptors and pressure connections Four tube

More information

Cold Vacuum Drying Facility Stack Air Sampling System Qualification Tests

Cold Vacuum Drying Facility Stack Air Sampling System Qualification Tests PNNL-13401 Cold Vacuum Drying Facility Stack Air Sampling System Qualification Tests J. A. Glissmeyer January 2001 Prepared for the U.S. Department of Energy under Contract DE-AC06-76RL01830 DISCLAIMER

More information

Southwest Clean Air Agency NE 99 th St, Suite 1294, Vancouver, WA 98682

Southwest Clean Air Agency NE 99 th St, Suite 1294, Vancouver, WA 98682 Source Test Guidance Test plans are required to be submitted to SWCAA prior to testing. Generally the plans must be submitted 2 weeks prior to testing but may be different based on individual facility

More information

Water Measurement. Presentation by. L. Niel Allen Extension Irrigation Specialist Utah State University

Water Measurement. Presentation by. L. Niel Allen Extension Irrigation Specialist Utah State University Water Measurement Presentation by L. Niel Allen Extension Irrigation Specialist Utah State University to Utah State Engineer s Office Division of Water Rights Salt Lake City, Utah December 11, 2013 Introduction

More information

Rolling processes. Fig. (5-1)

Rolling processes. Fig. (5-1) Page1 Rolling processes 5-1 introduction: Rolling is the process of reducing the thickness or changing the cross section of a long workpiece by compressive forces applied through a set of rolls, as shown

More information

PM2.5/10. APEX INSTRUMENTS, INC. Method for Determination of PM10 / PM2.5 Emissions (Constant Sampling Rate Procedure) Operator s Manual

PM2.5/10. APEX INSTRUMENTS, INC. Method for Determination of PM10 / PM2.5 Emissions (Constant Sampling Rate Procedure) Operator s Manual 20 PM2.5/10 APEX INSTRUMENTS, INC. Method for Determination of PM10 / PM2.5 Emissions (Constant Sampling Rate Procedure) Operator s Manual Apex Instruments, Inc. P.O. Box 727, 125 Quantum Street Holly

More information

NJ AIHA CIH Review Industrial Ventilation

NJ AIHA CIH Review Industrial Ventilation NJ AIHA CIH Review Industrial Ventilation Thomas Block, CIH MPH tblock@aps.rutgers.edu 848-445-2550 2016 American Industrial Hygiene Association, New Jersey Section, Inc. Course Objectives At the end of

More information

STEEL STRUCTURAL SYSTEMS

STEEL STRUCTURAL SYSTEMS STEEL STRUCTURAL SYSTEMS Steel elements are of two basic types: Structural steel shapes are formed into their final shapes by hot-rolling. This method produces such common elements as wide flange sections,

More information

FLUID MECHANICS CIVIL ENGINEERING VIRTUAL LABORATORY

FLUID MECHANICS CIVIL ENGINEERING VIRTUAL LABORATORY FLUID MECHANICS CIVIL ENGINEERING VIRTUAL LABORATORY EXPERIMENT: 2 VENTURI METER INTRODUCTION: The Ventura meter used in this experiment consists of successive converging, uniform and diverging sections

More information

INSTALLATION GUIDELINES ELBOWS

INSTALLATION GUIDELINES ELBOWS ELBOWS NOTE: Silencer baffles should be parallel to the plane of the elbow. L & L U D Radius Elbows and Square Elbows with Turning Vanes Deq x 3 Deq x 2 Deq x 1 Deq x 0.5 Directly Connected 1.0 1.25 1.75

More information

Contact the Jurisdictional Engineer for materials allowed by each jurisdiction.

Contact the Jurisdictional Engineer for materials allowed by each jurisdiction. Design Manual Chapter 3 - Sanitary Sewers 3C - Facility Design 3C-1 Facility Design A. Capacity of Pipe Pipe sizes 15 inches and smaller should carry the peak flow at a depth of no more than 0.67 of the

More information

The Study of Close Loop Wind Tunnel & Design & Construction of Table Mounted One

The Study of Close Loop Wind Tunnel & Design & Construction of Table Mounted One The Study of Close Loop Wind Tunnel & Design & Construction of Table Mounted One Syed Ehsanur Rahman Aeronautical Engineering Department Md. Abu Taher Ali Professor, Aeronautical Engineering Department

More information

VENTURI FLOWMETERS. Your First Choice in Intelligent Flow Management...

VENTURI FLOWMETERS. Your First Choice in Intelligent Flow Management... VENTURI FLOWMETERS Your First Choice in Intelligent Flow Management... VENTURI FLOWMETERS Preso s complete line of Venturis offer reduced operating costs, proven accuracy, and great rangeability. Low permanent

More information

Flow Test Data Book and Flow Handbook for 405 Compact Orifice Series and 1595 Conditioning Orifice Plate

Flow Test Data Book and Flow Handbook for 405 Compact Orifice Series and 1595 Conditioning Orifice Plate Test Book and Handbook for 405 Compact Orifice Series and 1595 Conditioning Orifice Plate Title Page 405 Compact Orifice Series and 1595 Conditioning Orifice Plate Test Book NOTICE Read this manual before

More information

Cambridge Environmental Technologies 105 Goodwill Road Cambridge, MD Tel:

Cambridge Environmental Technologies 105 Goodwill Road Cambridge, MD Tel: Comparison Tests and Product Validation Testing of Cambridge Environmental Technologies Electrostatic Precipitators for Wood-Fired Boiler Applications April 2012 Dr. Grace Pokoo-Aikins Cambridge Environmental

More information

NEW JERSEY DEPARTMENT OF ENVIRONMENTAL PROTECTION NEW JERSEY ADMINISTRATIVE CODE TITLE 7, CHAPTER 27B SAMPLING AND ANALYTICAL PROCEDURES

NEW JERSEY DEPARTMENT OF ENVIRONMENTAL PROTECTION NEW JERSEY ADMINISTRATIVE CODE TITLE 7, CHAPTER 27B SAMPLING AND ANALYTICAL PROCEDURES NEW JERSEY DEPARTMENT OF ENVIRONMENTAL PROTECTION NEW JERSEY ADMINISTRATIVE CODE TITLE 7, CHAPTER 27B SAMPLING AND ANALYTICAL PROCEDURES SUBCHAPTER 1. SAMPLING AND ANALYTICAL PROCEDURES FOR DETERMINING

More information

ME 215. Mass and Energy Analysis of Control Volumes CH-6 ÇANKAYA UNIVERSITY. Mechanical Engineering Department. Open Systems-Control Volumes (CV)

ME 215. Mass and Energy Analysis of Control Volumes CH-6 ÇANKAYA UNIVERSITY. Mechanical Engineering Department. Open Systems-Control Volumes (CV) ME 215 Mass and Energy Analysis of Control Volumes CH-6 ÇANKAYA UNIVERSITY Mechanical Engineering Department Open Systems-Control Volumes (CV) A CV may have fixed size and shape or moving boundaries Open

More information

K. All mechanical rooms shall be designed with a minimum 3-1/2 dropped floor.

K. All mechanical rooms shall be designed with a minimum 3-1/2 dropped floor. PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

Master Meter Testing at Water Plants and Pump Stations. Jeff Cruickshank, PE

Master Meter Testing at Water Plants and Pump Stations. Jeff Cruickshank, PE Master Meter Testing at Water Plants and Pump Stations Jeff Cruickshank, PE NC AWWA-WEA Spring Conference Asheville, NC April 11, 2015 Presentation Outline What types of meters are used at WTPs and pump

More information

Service Call: Determining if the structural damage to a fiberglass boom is repairable

Service Call: Determining if the structural damage to a fiberglass boom is repairable Service Call: Determining if the structural damage to a fiberglass boom is repairable Tools Required: Appropriate Maintenance Manual for the unit, with the correct Fiberglass Damage Charts Tape measure

More information

SPECIFICATION FOR PRECIPITATION-HARDENING NICKEL ALLOY BARS, FORGINGS, AND FORGING STOCK FOR HIGH-TEMPERATURE SERVICE

SPECIFICATION FOR PRECIPITATION-HARDENING NICKEL ALLOY BARS, FORGINGS, AND FORGING STOCK FOR HIGH-TEMPERATURE SERVICE SPECIFICATION FOR PRECIPITATION-HARDENING NICKEL ALLOY BARS, FORGINGS, AND FORGING STOCK FOR HIGH-TEMPERATURE SERVICE (Identical with ASTM Specification B 637-93a) 1. Scope 1.1 This specification covers

More information

Pulverized Coal Extractive Testing Methods Evaluation at the EPRI Coal Flow Loop

Pulverized Coal Extractive Testing Methods Evaluation at the EPRI Coal Flow Loop Pulverized Coal Extractive Testing Methods Evaluation at the EPRI Coal Flow Loop Robert Mudry, P.E. Matthew Fleming Airflow Sciences Corporation Livonia, Michigan Richard Brown Jose Sanchez The Electric

More information

Concrete Strength Testing Technician Study Guide

Concrete Strength Testing Technician Study Guide Concrete Strength Testing Technician Study Guide ASTM C 617 CAPPING CYLINDRICAL CONCRETE SPECIMENS 1. Neat cement caps and high-strength gypsum-plaster shall be formed against a glass plate at least in.

More information

A STUDY ON FLOW BEHAVIOR INSIDE A SIMPLE MODEL OF EJECTOR

A STUDY ON FLOW BEHAVIOR INSIDE A SIMPLE MODEL OF EJECTOR A STUDY ON FLOW BEHAVIOR INSIDE A SIMPLE MODEL OF EJECTOR Taketoshi Koita 1 and Junjiro Iwamoto ABSTRACT This paper is concerned with the experimental results on the internal flow of the ejector. To improve

More information

Standard Test Method for Apparent Hoop Tensile Strength of Plastic or Reinforced Plastic Pipe by Split Disk Method 1

Standard Test Method for Apparent Hoop Tensile Strength of Plastic or Reinforced Plastic Pipe by Split Disk Method 1 Designation: D 2290 00 e1 An American National Standard Standard Test Method for Apparent Hoop Tensile Strength of Plastic or Reinforced Plastic Pipe by Split Disk Method 1 This standard is issued under

More information

CEM Gilles Gonnet Ecomesure, B.P. 13, F Briis Sous Forges, France telephone: fax:

CEM Gilles Gonnet Ecomesure, B.P. 13, F Briis Sous Forges, France telephone: fax: CEM 2004 Real Time Measurement Of Particulate At Low Concentration From The Emission Of Stationary Source In The Steel And Power Industries Using a TEOM based Emissions Monitor Edward C. Burgher Rupprecht

More information

NOZZLES NOZZLES NOZZLES

NOZZLES NOZZLES NOZZLES 06 07 JET JET JET SJN SERIES Dimensions SJN consist of a spherical discharge nozzle mounted in a housing and is complete with a front mounting flange and circular spigot for direct connection to circular

More information

Method For Test-Fueling Residential Wood-Fired Masonry Heaters and Bake Ovens

Method For Test-Fueling Residential Wood-Fired Masonry Heaters and Bake Ovens Method For Test-Fueling Residential Wood-Fired Masonry Heaters and Bake Ovens April 20, 2009 Copyright The : 2009. www.mha.net.org Test Fueling Masonry Heaters Page 1 of 29 Method For Test-Fueling Residential

More information

INSTALLATION PROCEDURE

INSTALLATION PROCEDURE INSTALLATION PROCEDURE VOLU-probe/1, /3, /4 for Round Ducts INSPECTION & HANDLING. VOLU-probes should be carefully inspected for damage prior to installation. Report damage to your Freight Department,

More information

MODERN PRACTICES FOR MEASUREMENT OF GAS PATH PRESSURES AND TEMPERATURES FOR PERFORMANCE ASSESSMENT OF AN AXIAL TURBINE

MODERN PRACTICES FOR MEASUREMENT OF GAS PATH PRESSURES AND TEMPERATURES FOR PERFORMANCE ASSESSMENT OF AN AXIAL TURBINE Review of the Air Force Academy No.1 (33)/2017 MODERN PRACTICES FOR MEASUREMENT OF GAS PATH PRESSURES AND TEMPERATURES FOR PERFORMANCE ASSESSMENT OF AN AXIAL TURBINE Daniel OLARU, Valeriu VILAG, Gheorghe

More information

UNIT V PLASTIC ANALYSIS

UNIT V PLASTIC ANALYSIS SIDDHARTH GROUP OF INSTITUTIONS :: PUTTUR Siddharth Nagar, Narayanavanam Road 517583 QUESTION BANK (DESCRIPTIVE) Subject with Code : SA-II (13A01505) Year & Sem: III-B.Tech & I-Sem Course & Branch: B.Tech

More information

Rectangular sound attenuator

Rectangular sound attenuator Rectangular sound attenuator Description The type sound attenuator was designed to fit rectangular ducts. The attenuator was developed specifically to reduce noise in certain octave bands primarily in

More information

Question Paper Code : 11410

Question Paper Code : 11410 Reg. No. : Question Paper Code : 11410 B.E./B.Tech. DEGREE EXAMINATION, APRIL/MAY 2011 Fourth Semester Mechanical Engineering ME 2254 STRENGTH OF MATERIALS (Common to Automobile Engineering and Production

More information

ACOUSTICAL DUCT & PIPE LAGGING INDUSTRIAL NOISE CONTROL PRODUCTS

ACOUSTICAL DUCT & PIPE LAGGING INDUSTRIAL NOISE CONTROL PRODUCTS 23 07 13 ACOUSTICAL DUCT & PIPE LAGGING INDUSTRIAL NOISE CONTROL PRODUCTS ACOUSTICAL DUCT AND PIPE LAGGING Acoustical Lagging is wrapped around the outside of duct or pipe to reduce the radiated noise

More information

Stationary source emissions Manual determination of mass concentration of particulate matter

Stationary source emissions Manual determination of mass concentration of particulate matter BRITISH STANDARD BS ISO 9096:2003 Stationary source emissions Manual determination of mass concentration of particulate matter ICS 13.040.40 This British Standard was published under the authority of the

More information

STACK AND BREECHING GUIDELINE

STACK AND BREECHING GUIDELINE TECHNICAL BULLETIN 1004 DECEMBER 1, 2007 STACK AND BREECHING GUIDELINE Common stacks and breechings can be designed as follows: 1. Determine volume of flue gases from Chart 1. Chart shows flue gas CFM

More information

Technical Manual Guidelines for Compliance Stack Emission Test Programs

Technical Manual Guidelines for Compliance Stack Emission Test Programs New Jersey Department of Environmental Protection Air Quality Permitting Program Bureau of Technical Services Technical Manual 1004 Guidelines for Compliance Stack Emission Test Programs For technical

More information

Technical Manual Guidelines for Compliance Stack Emission Test Programs

Technical Manual Guidelines for Compliance Stack Emission Test Programs New Jersey Department of Environmental Protection Air Quality Permitting Program Bureau of Technical Services Technical Manual 1004 Guidelines for Compliance Stack Emission Test Programs For technical

More information

HORIZONTAL SHELL SIDE FLUIDIZED BED HEAT EXCHANGER, DESIGN CONSIDERATIONS AND EXPERIENCES FROM A PILOT UNIT

HORIZONTAL SHELL SIDE FLUIDIZED BED HEAT EXCHANGER, DESIGN CONSIDERATIONS AND EXPERIENCES FROM A PILOT UNIT HORIZONTAL SHELL SIDE FLUIDIZED BED HEAT EXCHANGER, DESIGN CONSIDERATIONS AND EXPERIENCES FROM A PILOT UNIT M.C. van Beek 1, M. Cancela Vallespin 1, 1 Klaren International, Hanzeweg 35N, 3771 NG, Barneveld,

More information

AN INFLUENCE OF SST-2 MIXER-EJECTOR NOZZLE ELEMENTS VARIATIONS ON ITS AERODYNAMIC AND ACOUSTIC CHARACTERISTICS

AN INFLUENCE OF SST-2 MIXER-EJECTOR NOZZLE ELEMENTS VARIATIONS ON ITS AERODYNAMIC AND ACOUSTIC CHARACTERISTICS AN INFLUENCE OF SST-2 MIXER-EJECTOR NOZZLE ELEMENTS VARIATIONS ON ITS AERODYNAMIC AND ACOUSTIC CHARACTERISTICS Sergey Ju. Krasheninnikov, Alexey K. Mironov Central Institute of Aviation Motors (CIAM),

More information

3. technical data. Page 1 of 10

3. technical data. Page 1 of 10 Page of 0. DESCRIPTION Viking Quick Response Ordinary Hazard Dry Horizontal Sidewall Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The sprinklers are designed

More information

Procedure for Supplementary CMM Measurements for Quartz Block #3 P0457

Procedure for Supplementary CMM Measurements for Quartz Block #3 P0457 1 INTRODUCTION Procedure for Supplementary CMM Measurements for Quartz Block #3 P0457 1.1 Objective. The objective of this procedure is to make supplemental coordinate measuring machine (CMM) measurements

More information

Trade of Sheet Metalwork. Module 5: Ductwork Unit 3: 90 Radius Bend with Proprietary Flanges Phase 2

Trade of Sheet Metalwork. Module 5: Ductwork Unit 3: 90 Radius Bend with Proprietary Flanges Phase 2 Trade of Sheet Metalwork Module 5: Ductwork Unit 3: 90 Radius Bend with Proprietary Flanges Phase 2 Table of Contents List of Figures... 5 List of Tables... 5 Document Release History... 6 Module 5 Ductwork...

More information